Home
VarioAnalyze User Manual - Instruments Techno Test
Contents
1. See Section 6 VarioAnalyze Explorer window 2 Open the IRB image you want by double clicking on the preview 3 Using the toolbar icons Previous and Next display the images from the directory in succession in the Analy sis window search directory See Section 7 2 Toolbar in the Analysis window 4 Adjust temperature scale See Section 7 3 4 1 Limits 5 Draw the shapes ROIs you want in the current image Use the toolbar icons in the Analysis window See Section 7 2 Toolbar in the Analysis window 83 84 6 Correct measurement results evaluation Global for the whole image Shape For each shape individually See Section 7 3 6 Correction menu 7 Save copy print export etc measurement results evalu ation See Section 7 3 1 File menu 8 Generate report See Section 8 Create report Report window 10 Service and support Service and support The VarioAnalyze software is a powerful tool for managing analyzing and evaluating thermal images which were taken using thermal cameras from JENOPTIK If you have questions or advice about the cameras or soft ware please consult your authorized dealer for JENOPTIK thermal cameras or contact us directly at JENOPTIK Laser Optik Systeme GmbH Business unit Sensor Systems Infrared Technology G schwitzer Strasse 25 07745 Jena Germany Phone 49 3641 65 30 29 Fax 49 3641 65 34 94 Email inf
2. The values are encoded in the header of the IRB file Select palette area Select the color palette for the temperature scale from the combo box VARIOCAM BlackWhite lronBow BlueRed MrkedBW Representation in the color palette of the VarioCam Gray scale representation Color palette in the tempering colors of steel Color palette from blue low tempera tures to red high temperatures Marked Black White Color palette in gray scale representation with color marking of high temperatures red and low temperatures blue VarioAnalyze Analysis window Rainbow Color palette in the colors of the rain bow Steps Define number of color steps invers Invert selected color palette 7 3 4 2 Units Define temperature and length units for image representa tion in the window gt The Select units window opens Temperature Distance f Celsius Ce Meter Kelvin Foot i Fahrenheit a Fig 7 6 Select units window j K Celsius Temperature Possible temperature units e Celsius e Kelvin e Fahrenheit Distance Possible length units e Meter e Foot SE 54 7 3 4 3 Grid settings Place the measuring grid on the IR image Measuring grids can be used to simplity the structure of the image contents and for thermal categorization of thermo gram areas gt The Grid settings window opens E Show grid Font selection a ee Colour selection Line distance 60 v Lin
3. function It is automati cally displayed again when a new shape ROI is drawn R1 236 114 596 352 40 6 C 25 4 C 75 9 C 14 61 C 1 00 E2 68 66 196 172 30 6 C 26 9 C 51 6 C 2 89 C 1 00 L3 208 64 639 64 31 2 C 29 5 C 37 6 C 1 56 C 1 00 Measurement results for three different shapes ROI Meanings ROI Name and coordinates of shape ROI region ot interest see 7 3 4 Thermo gram menu Avg Average temperature Min Minimum temperature Max Maximum temperature Sdv Standard deviation Eps Emissivity 47 48 7 3 3 2 7 3 3 3 7 3 3 4 To edit correct the measured values and parameters Click on the table with the right mouse button gt A separate window with the measurement results opens see Section 7 3 5 Measure menu Show temperature scale Display hide temperature scale The temperature scale in the selected color palette is dis played at the right hand edge next to the IR image A check mark before the menu bar indicates whether the function Is activated To edit correct the temperature scale click on the scale with the right mouse button A separate window for editing opens see also Section 7 3 4 Thermogram menu Profile Display hide temperature profiles for marked axes A check mark before the menu bar indicates whether the function is activated After the function Is selected 1 When the function is called up a crosshair pointe
4. 10 48 VarioCAM 320x240 Paget Wednesday February 11 200410 48 MN Fig 6 3 Print preview for printing from the VarioAnalyze Explorer window As well as the image content the following file information is included in the print view e Path and filename e Date e Which camera was used format breadth and height in number of pixels 25 26 6 3 1 10 6 3 1 11 Function buttons in the Print Preview window Print Start printing Zoom In Zoom into image enlarge representa tion Zoom Out Zoom out of image reduce representa tion Close Close print preview To print the image 1 Click on Print gt The Windows print window opens 2 Select printer make settings for paper size orientation color options etc 3 Click on OK gt The image is printed Print Setup Select the printer and printer connection for VarioAnalyze Define printer settings gt The Windows print window is opened In the Windows print window 1 Select printer make settings for selected printer e g paper size orientation color options etc 2 Click on OK gt The settings are accepted as default settings for Var ioAnalyze and called up at every start of the print function Exit End VarioAnalyze Explorer 6 3 2 6 3 2 1 6 3 2 2 Edit menu The Edit menu has the following options e Image sequence e Change comment The functions of the Edit menu are available only if the Pre
5. 16 bit color depth true color Screen resolution Minimum 1024 x 768 pixels 1280 x 1024 pixels or higher recommended Supplied items and system prerequisites Installation 4 Installation To install the software directly from the data medium 1 Insert the CD ROM into the CD ROM drive of the PC 2 To install the English version Double click on the file varioanalyze_engl exe to install the Japanese version Double click on the file varioanalyze_jpn exe to install the Spanish version Double click on the file varioanalyze_spn exe 3 Click on OK to confirm that you want to continue with the installation of VarioAnalyze gt Program installation is started 4 If required select the desired program folder gt The software is installed in full gt After installation the program folder contains among other things the files varioanalyze exe var oanalyzemess exe varioanalyze hlp varioana lyzemess hlp and the subdirectories Colors Images and Doc The Colors directory contains the color palette files The Images directory contains example images gt The VarioAnalyze program icon is installed on the desktop if this option was chosen gt The installation routine reports that installation is complete The program can now be used Installation 5 1 5 2 Starting and ending the progam Starting and ending the program Starting the program 1 Start VarioAnalyze by double clicking with the left mouse butt
6. 43 44 7 3 2 6 7 3 2 7 Copy to report Copy current window content into open Report window The function is available only if a Report window is open and at least one graphic field is free in it The image is cop ied to the first free graphic field of the Report form To open a Report window use the functions Create new report or Open existing report see Section 7 3 8 Re port Set selection Create a selection area in the image The selection is independent of any shape and can be marked in addition to shapes The selection area can be used to define the temperature scale or copied to other ap plications via the Clipboard see also Sections 7 3 4 1 Lim its and 7 3 2 3 Copy selection A check mark before the menu bar and the printed icon indicate whether the function is activated To create a selection 1 With the function activated click with the left mouse button on the starting point of the desired selection rect angle in the IR image 2 Keep the mouse button pressed and drag to the desired end point 3 Release the mouse button The outline of the selection rectangle is drawn by drag ging To remove a selection Click again on the menu option or icon 7 3 2 8 7 3 2 9 7 3 2 10 7 3 2 11 Fig 7 3 Mirror Mirror the image horizontal Mirror on the horizontal center axis vertical Mirror on the vertical center axis Rotate Rotate the image Left 90 Rota
7. 7 42 7 4 3 8 1 8 1 1 Status bar Thermogram menu Limits Units Grid settings Temperature Matrix Isotherms Point Line Rect Circle Ellipse Polygon Next Previous Measure menu Measurement results Correction menu Definition Extras menu Options Arrange icons Report menu Create new report Open existing report Help menu Help About VarioAnalyze Direct access with right mouse click Thermogram Edit shapes Change limits and color palette Save print export thermograms Create report Report window Structure and function of the Report window Edit report fields 50 51 51 SE 54 55 5 5 5 58 58 58 58 58 58 59 59 60 60 63 63 66 6 6 68 69 69 69 70 70 73 74 75 75 71 8 2 8 2 1 8 2 1 1 8 2 1 2 8 2 1 3 8 2 1 4 8 2 1 5 8 2 1 6 8 2 1 7 8 2 1 8 8 2 2 8 2 2 1 8 2 2 2 8 2 2 3 8 2 3 9 2 0 1 8 2 3 2 8 2 3 3 10 Changing the properties of a report field and importing images Menu description in the Report window File menu Open Save Save as Save template as Send Print preview Print Exit Edit menu Copy the page Add page Delete page View menu Next page Previous page Change the template General procedure for image evaluation Service and support Instructions for using this manual Instructions for using this manual In this manual the following linguistic and typographic syn o
8. Shapes tab Shapes tab Define correction definitions for each shape individually x Global Shapes Correction definitions window Shapes tab 61 VarioAnalyze Analysis window 1 Select a line shape 2 Click on Edit alternatively double click on the Shape line gt The Edit dialog opens Edit correction definitions shapename window Edit correcture definitions E1 x r Extinction iseiyi 1 00 Emissivity Distance m 2 0 Environment temp 20 0 Absorption Path temp 20 0 0 0 Transmissivity 1 0000 Get Transmissivity e Fig 7 14 Edit correction definitions window In the Edit correction definitions window 3 Correct the data as for the Global tab and confirm with OK gt The image display in the Analysis window is immedi ately updated 4 Close the window by clicking on x 62 7 3 7 7 3 7 1 Fig 7 15 VarioAnalyze Analysis window Extras menu The Extras menu has the following options e Options e Arrange icons Options Select settings and program options gt Options window opens The Options window has three tabs e Generally e Parameter e Global Properties Generally tab Do settings for representation in the Analysis window Generally Parameter Global Properties Temperature presentation EE Rul s font Comment s font Background Profile backgro
9. etc 3 Click on OK gt The image is printed Print Setup Select the printer and printer connection for VarioAnalyze Define printer settings gt The Windows print window is opened In the Windows print window 1 Select printer make settings for selected printer e g paper size orientation color options etc 2 Click on OK gt The settings are accepted as default settings for Var ioAnalyze and called up at every start of the print function Exit Close VarioAnalyze analysis window end program If ap propriate there is a safety query with the option of storing changes measurement results table report 41 42 7 3 2 7 3 2 1 7 3 2 2 Edit menu The Edit menu has the following options e Undo e Copy e Copy selection e Copy measurement results e Copy measurement results ASCII e Copy to report e Set selection e Mirror e Rotate e Filter e Change comment Undo Undo previous action if possible This function is available only if an action which can be un done has taken place The name of the function varies de pending on what the last action was It changes to Can t Undo if the last action cannot be undone The following actions can be undone e mirroring e rotations e applying filter Copy Copy current Analysis window view to the Clipboard gt Any contents which were previously stored in the Clipboard are overwritten 7 3 2 3 7 3 2 4 7 3 2 5 Co
10. sets the stored ROls in the current image Close the window by clicking on x 59 VarioAnalyze Analysis window 60 7 3 6 7 3 6 1 Fig 7 12 Correction menu The Measure menu has one option e Definition Definition Correct values which affect the measurements e g ambient temperature emissivity transmissivity etc gt The Correction definitions window opens The window has two tabs e Global e Shapes Global tab Define correction definitions for the whole current image Correcture definitions x Global Shapes Extinction Emissivity 1 00 Distance m Environment temp C 20 0 f2 0000 Absorption Path temp C 20 0 P fo D Transmissivity 1 00 Get Transmissivity Correction definitions window Global tab Fig 7 13 VarioAnalyze Analysis window In the Correction definitions window Global tab 1 On this tab correct if required corresponding to the actual conditions when the image was taken Emissivity Ambient temperature Path temperature Transmissivity 2 Alternatively to direct entry you can also calculate the transmissivity of the object environment by entering the values for distance and absorption and copy this value by clicking on Get Transmissivity 3 Click on Apply to apply the entries gt The image display in the Analysis window is immedi ately updated 4 Change to the
11. the program Structure of the software user interface VarioAnalyze Explorer window VarioAnalyze Analysis window End program VarioAnalyze Explorer window Structure and function Toolbar in the VarioAnalyze Explorer window Menu description in the Explorer window File menu New root Save Save as Send New folder Previous folder Refresh directories Print Print preview Print Setup Exit Edit menu Image sequence Change comment View menu Settings Toolbar Content 11 13 15 15 15 16 16 17 19 19 21 22 22 23 23 23 24 24 24 24 24 23 26 26 27 27 27 28 28 29 Status bar Help menu Help About VarioAnalyze VarioAnalyze Analysis window Structure and function of Analysis window Toolbar in the Analysis window Menu description in the Analysis window File menu Open Save Save as Print Print preview Print Setup Exit Edit menu Undo Copy Copy selection Copy measurement results Copy measurement results ASCII Copy to report Set selection Mirror Rotate Filter Change comment View menu Show measurement results Show temperature scale Profile Comment Parameters Visible image Toolbar 7 3 3 8 7 3 4 7 3 4 1 7 3 4 2 7 3 4 3 7 3 4 4 7 3 4 5 7 3 4 6 7 3 4 7 7 3 4 8 7 3 4 9 7 3 4 10 7 3 4 11 7 3 4 12 7 3 4 13 7 3 5 e a 7 3 6 7 3 6 1 1 3 1 7 3 7 1 7 3 7 2 7 3 8 1 3 8 1 Le 1 3 9 7 3 9 1 e 7 4 7 4 1
12. with the left mouse button on the preview im age to open IRB files in the Analysis window The other formats bmp pcx are displayed only as preview image and cannot be opened in the Analysis window Right click on a marked image to open a flyout menu with the options Print Print the selected image opens the print preview window see Section 6 3 1 9 Print preview Save as Save IRB files see Section 6 3 1 3 Save as 6 2 Toolbar in the VarioAnalyze Explorer window The icons in the toolbar are used to operate the software quickly using the mouse The functions which they repre sent can also be reached via the menus of the VarioAnalyze Explorer window In the menu description of the Explorer window you will find the icon corresponding to each menu item Change the shown directory to the next higher level Create a new folder Save as Stores the selected thermogram in a freely selectable direc tory VarioAnalyze displays the Save As dialog window See Section 6 3 1 File menu No preview images On the right side of the VarioAnalyze Explorer screen the thermograms will just get shown with their filename date file type camera type and pixel resolution in a list form No preview images are shown See Section 6 3 3 View menu Small preview images Small thumbnails 80x60 pixels are displayed in the Preview area See Section 6 3 3 View menu Large preview imag
13. 18 37 F 86 86 F 152 82 F R3 368 119 387 200 110 10 F 103 55 F 123 715F P4 611 230 128 51 F P5 265 311 141 96 F February 11 2004 09 4 variocam 1 85 EH LG JENOPTIK Group Dear User Dear User You should carefully read these instructions before you start operating the VarioAnalyze Software Editorial deadline October 2005 Document number 014801 021 98 02 1005 english JENOPTIK Laser Optik Systeme GmbH G schwitzer Stra e 25 D 07745 Jena Germany Phone 49 3641 65 3942 Fax 49 3641 65 3494 E mail infraredtechnology jenoptik com CE Note No part of this User Manual may be reproduced in any form print photo copy microfilm or any other process nor may it be processed duplicated or distributed using electronic systems without the written permission of JENOPTIK Laser Optik Systeme GmbH This document was produced with appropriate care No liability will be accepted in the case of damages arising from non observance of the information contained herein We reserve the right to modify this document following technical advancements Content 6 3 1 6 3 1 1 6 3 1 2 6 3 1 3 6 3 1 4 6 3 1 5 6 3 1 6 6 3 1 7 6 3 1 8 6 3 1 9 6 3 1 10 6 3 1 11 6 3 2 6 3 2 1 6 3 2 2 6 3 3 6 3 3 1 6 3 3 2 Instructions for using this manual Application field of VarioAnalyze Supplied items and system requirements Installation Starting and ending the program Starting
14. 4 10 February 11 2004 10 52 February 11 2004 10 v Rb 40211003 BMP 40211003 IRB 40211004 IRB February 11 2004 11 02 February 11 2004 10 February 11 2004 11 02 February 11 2004 10 EN e la gt ER hs Win 40211005 BMP R February 11 2004 11 02 num 4 Explorer window From the Explorer window you can open the desired IR IM age directly Double click on the preview image in the right hand part of the window to show the image in the Analysis window For a description of the Explorer window see Chapter 6 VarioAnalyze Explorer window VarioAnalyze Analysis window GF 4021 1001 1RB YarioAnalyze Basic ll x Nm eek il z File Edit View Thermogram Measure Correction Extras Report Help CHA ole Leen gt 81a m m 309 21 30 0 C February 11 2004 10 4 VariocaMm 1 4 num Y Analysis window For a description of the Analysis window see Chapter 7 VarioAnalyze Analysis window 5 3 End program 1 Select in succession in the Explorer window and Analysis window File Exit or close the current window by clicking on x gt VarioAnalyze is ended If required you have the op portunity to save data which has not been stored until now Starting and ending the program 6 1 Fig 6 1 VarioAnalyze Explorer window VarioAnalyze Explorer window Structure and function In Explorer window e Select the directory in which the IR images to be a
15. JENOPTIK JENA LaserOptik VarioAnalyze Systeme User Manual GP p ablage IR eigene Thermogramme YarioCAM arioAnalyze i Oo x File Edit View Help STT ALLGEMEI I Backup Systemdateien E Controlling ze CRM GJ IR Anfragen Angebote E Banr EES Eoioene Thermogramme Varioc s 1 50 Hz Sequences den 3 BEER Energieversorgu k SUE f Oxf E Game Japan File Edit View Thermogram Measure Correction Extras Report Help G Hero Quebec gt Afos variocan gt 8a mm a me M wc Japan Steel mee A Jenoptik VARIOCAM E Lasertechnik_04 5 Laufende Person zs 1 MDC Koelleda I Mohlsdorf C Motherboard E OTIS Elevator amp pce vs H Ricardo 5 Schlachthof Jena E Security 3 Sequenz Rihga H 1 Test Audio 0001 irb 40211001 BMP 40211001 IRB April 22 2005 10 February 11 2004 09 48 November 08 2005 23 I 40211002 BMP 40211002 IRB 40211003 BMP February 11 2004 09 52 February 11 2004 09 February 11 2004 10 02 ERC VarioCAM head 40211002 IRB February 11 2004 Emissivity 1 00 VarioCAM Path temp 68 00 E Transmissivity 1 00 Absorption 0 00 Distance 2 0 m 09 49 Zoom 1 00 Env temp 68 00 F C1 338 269 418 349 stake Filet ae 168 62 F L2 339 20 417 20 1
16. Polygon Draw a measuring area shape in arbitrary form The draw ing of the polygon is ended by a double click or right click on the starting point To change the shape properties position size name emis sivity see Section 7 4 1 Thermogram Edit shapes Next Display next IRB image The next IRB image in the current directory is displayed Previous Display previous IRB image The previous IRB image in the current directory is displayed 7 3 5 1 3 9 1 Fig 7 11 S a s wind OW MM AX J VV d amp el W w Measure menu The Measure menu has one option e Measurement results Measurement results Display measurement results for shapes ROI gt A separate window with the table representation of the measurement results for all shapes opens 40211002 IRB Measurement results x R1 236 114 596 352 406 C 254 C 75 9 C 14 61 C E2 68 66 196 172 306 C 269 C 516 289C L3 208 64 639 64 31 2 295 C 37 6 C 1 56 C Delete Correction Save Load Measurement results window The buttons open the following functions Delete Delete marked shapes ROI To delete confirm the safety query Correction Opens the dialog Correction defini tions see Section 7 3 6 Correction menu Save Saves the position and properties of the current shapes ROIs as a roi file The filename can be freely chosen Load Opens a roi file and
17. an also be reached via the menu This section summarizes the essential functions which can be reached by a right click e Edit shapes in a thermogram change size position e Edit temperature limits and color palette of a thermo gram representation e Save copy and print the content of the Analysis window thermogram with displayed measured values color pal ette etc Thermogram Edit shapes If you have drawn shapes ROls into the image to evalu ate your thermogram you have the option of changing the properties of each individual shape subsequently Proceed as follows 1 In the Analysis window click with the right mouse but ton on the label of the shape to be corrected e g R1 gt The Change properties for shapename window opens VarioAnalyze Analysis window x Position Size a al Line 88 175 H a gt al i gt IT Column 140 245 H Label position Hana A a S D C Emissivity 1 00 Apply Delete Show minimum Show maximum Fig 7 20 Change properties for shapename window 2 Correct the properties of the shape by using the scroll bars or by entries in the text fields Position Label position Size Name Emissivity gt You can observe the result in the image immediately if you place the Change properties window appro priately on your screen 71 VarioAnalyze Analysis window 12 Fig 7 21 BF 4021 1001 IRB Yar
18. ay hide toolbar in the Analysis window A check mark before the menu bar indicates whether the Toolbar is displayed For an explanation of the icons of the toolbar see Section 7 2 Toolbar in the Analysis window Status bar Display hide status bar in Analysis window A check mark before the menu bar indicates whether the Status bar is displayed The status bar displays information in 8 fields of different sizes from left to right Field 1 e For navigation in the image current cursor position in image pixel and associated temperature value e For navigation in the menu description of the menu function which is currently marked if you move the cur sor through the menus using the arrow keys of the key board e H available a description of the function of the printed icon in the toolbar Field 2 Date and time image was taken Field 3 Name of camera which was used to take the image Field 4 Serial number of thermogram in current image directory Data serial number total number Field 5 Not used Fields 6 to 8 CAP Caps lock key is pressed NUM Num lock key is pressed SCRL Scroll lock key is pressed 7 3 4 7 3 4 1 Fig 7 5 Meel LI VM us IyZzC J A A gt y ZE ANa P ar n Anao L lysis wind d OW Thermogram menu The Thermogram menu has the following options e Limits e Units e Grid setting e Temperature Matrix e sotherms e Poi
19. e see also Section 7 3 4 1 Limits Table of measurement results Displays the measurement results if shapes shapes ROIs regions of interest are drawn into the IR image ROI Name and coordinates see Section 7 3 4 Thermogram menu Avg Average temperature Min Minimum Max Maximum Sdv Standard deviation Eps Emissivity 33 34 To correct edit the measured values Click on the table with the right mouse button gt A separate window with the table of measured val ues opens In this window it is possible to save load and delete shapes and change correction values globally for individual shapes See Section 7 3 5 Measure menu 7 2 Toolbar in the Analysis window Icons The icons are used to operate the software quickly using the mouse The functions which they represent can also be reached via the menus of the Analysis window In the menu description of the Analysis window you will find the icon corresponding to each menu item Open Open new IRB file VarioAnalyze displays the Open Win dows dialog window See Section 7 3 1 1 Open Save as Store the current IRB image VarioAnalyze displays the Save As dialog window See Section 7 3 1 3 Save as Print preview Print current view of open image VarioAnalyze opens a print preview window after again confirming the Windows print window See Section 7 3 1 5 Print preview Previous Image Opens th
20. e previous IRB image which is stored in the same directory paging through a sequence See Section 7 3 4 13 Previous Next image Opens the next IRB image which is stored in the same di rectory paging through a sequence See Section 7 3 4 12 Next Zoom Display next smaller representation zoom out ZOOM Display next larger representation zoom in 35 36 a D Mia we In je Set the selection Set the selection window See Section 7 3 2 7 Set selec tion Profile Display vertical and horizontal temperature profile for the axes of the crosshair pointer which appears see also Sec tion 7 3 3 3 Profile Minimum Display minimum temperature in image Maximum Display maximum temperature in image Point Set temperature measuring point A shape in the form of a point can be set anywhere in the image Line Set temperature measuring line A shape in the form of a line can be set anywhere in the image Rect Rectangle Set rectangular temperature measuring area A shape in the form of a rectangle can be set anywhere in the image Circle Set circular temperature measuring area A shape in the form of a circle can be set anywhere in the image Ellipse Set elliptical temperature measuring area A shape in the form of an ellipse can be set anywhere in the image Polygon Set temperature measuring area of arbitrary form A shape of arbitrary form can be set anywh
21. e profiles Right click in the image to open a flyout menu with the op tions Save As Store the image as a new file e g in IRB JPG BMP ASC formats see Section 7 3 1 3 Save as Copy Copy the current window content to the Clipboard It is then possible to in sert it into other application programs Print Print the current image opens the Win dows print window see Section 7 3 1 4 Print Shapes ROls Regions of interest ROI shape which are drawn in for evaluation of an image For each shape the measurement results are listed in a table below the image see Item 7 in this figure Comment bar and parameter bar Top line displays the comment which is stored in the image For displaying or hiding the comment bar see Section 7 3 3 View menu Bottom line displays image parameters For displaying or hiding the command bar see Section 7 3 3 1 View menu Temperature profile Displays the vertical and horizontal temperature profile for the axes of the crosshair pointer The crosshair pointer ap pears and its position can be set if the Profile function has been called See Section 7 3 3 View menu Temperature scale Displays the temperature scale in the colors of the current color scale For displaying or hiding the temperature scale see Section 7 3 3 2 Show temperature scale Right click on the scale to open a window to edit the scale limits and color palett
22. e type Column distance 80 z C Solid V Average temperature Dashed Maximum Minimum o Fig 7 7 Grid settings window In the Grid settings window 1 Activate Show grid function to show IRB images in the Analysis window with measuring grid 2 Detine measuring grid properties Line distance Distance between vertical grid lines IN pixels Column distance Distance between horizontal grid lines in pixels Solid dashed line Choice of solid and dashed grid lines Font selection Font and size for temperature data Color selection Color for grid and font 3 To display temperature values in each grid cell select the desired options Average temperature Minimum temperature Maximum temperature VarioAnalyze Analysis window e 4021 1001 IRB YarioAnalyze Basic j Ioj x Fie Edit View Thermogram Measure Correction Extras Report Help VarioCAM head February 11 2004 10 4 variocam 1 6 ae ae Fig 7 8 Representation of an IR image with grid and giving the average temperature in each grid cell 7 3 4 4 Temperature Matrix Open the temperature matrix for the current image The temperature for each individual point of the image is given in a table gt The window imagename irb Temperature matrix opens 55 56 Fig 7 9 e 40211001 1RB Temperature matrix File Edit lEIx u 25 7 28 7 25 7 25 7 25 6 25 8 22 7 25 8 25 8 25 6 25 5 25 6 25 6
23. ed in the Preview area the associated filename Field 2 Date and time most recently marked image was taken The information remains even if another directory has already been opened in the directory tree Fields 3 to 5 CAP Caps lock key is pressed NUM Num lock key is pressed SCRL Scroll lock key is pressed Help menu The Help menu has the following options e Help e About VarioAnalyze Help Call up Help file About VarioAnalyze Display copyright and version information 7 1 Fig 7 1 VarioAnalyze Analysis window VarioAnalyze Analysis window Structure and function of Analysis window The Analysis window e Allows investigation of the open thermal image and dis plays its properties e Makes it possible to produce edit and print analysis re ports Menu and icon bar Open image Shapes ellipse rectangle Comment bar and parameter bar Temperature profile Temperature scale Table of measurement results NOUN BWYN VarioAnalyze Analysis window 31 ER From the Analysis window depending on the selected func tion other windows are opened as required e g Report window Menu and icon bar For a description of the menus see Section 7 3 Menu de scription in the Analysis window For a description of the icons see section 7 2 Toolbar in the Analysis window Image display Thermal image representation in selected color mode and with current temperatur
24. election Load wiew Set date Load image Set page no Measurement results Load Tile Delete Setup report element property window for a text field II 2 To change the field format activate Text or Graphic gt The associated options become available You can import images directly from the Analysis window into a graphic field A text field has the following options Font selection Define font Set date Copy today s date Set page no Copy current number of pages format page X Y multiline If active check mark allow multiline text A graphic field has the following options Alignment Image alignment in field left center right 8 2 8 2 1 Load view Insert view of the Analysis window IRB image and table of measurement re sults if displayed Load image Insert IRB image from Analysis window Measurement results Insert table of measurement results metafile Import is possible only if shapes are marked in the IRB image Load file Load image file e g logo The Win dows Open window then opens Supported image formats irb omp DCH jg The following option is always available Delete Delete current field content Menu description in the Report window The Report window has the following menus e File e Edit e View File menu In the File menu you will find the following options e Open e Save e Save as e Save template as e Send e Pri
25. ens ee x Isotherme Isothermes Isotherme3 Isotherme10 Isothermel lsotherme2 Isotherme3 Isotherme4 IsothermeS Isotherme6 al 27 6 al 27 8 1 M Active m Ber Apply Isotherms window 1 Specify the following properties for each isotherm Minimum temperature Maximum temperature Color 2 Click on Apply to confirm the entry for the isotherms you have just defined 3 To display the isotherms in the current image activate the Active function Point Draw a measuring area shape in the form of a point To change the shape properties position name emissivity see Section 7 4 1 Thermogram Edit shapes Line Draw a measuring area shape in the form of a line To change the shape properties position size name emis sivity see Section 7 4 1 Thermogram Edit shapes 5 7 3 4 8 7 3 4 9 58 Rect Rectangle Draw a measuring area shape in the form of a rectangle To change the shape properties position size name emis sivity see Section 7 4 1 Thermogram Edit shapes Circle Draw a measuring area shape in the form of a circle To change the shape properties position size name emis sivity see Section 7 4 1 Thermogram Edit shapes Ellipse Draw a measuring area shape in the form of a ellipse To change the shape properties position size name emis sivity see Section 7 4 1 Thermogram Edit shapes
26. ere in the image The outline of the shape is generated by clicking on the desired positions The drawing of the polygon is ended by a double click or right click on the starting point Show VIS Shows the digital photo visible image of the current IR im age in a separate window see also Section 7 3 3 6 Visible image g Play audio Plays the audio information for the image available only if an audio recording exists Combo boxes The following combo boxes are integrated into the toolbar of the Analysis window Set zoom Select enlargement of the display Change palette Select color palette see Section 7 3 4 1 Limits Temperature unit Select unit for the temperature display see Section 7 3 4 2 Units 37 38 73 7 3 1 Menu description in the Analysis window File menu The File menu has the following options e Open e Save e Save as e Print e Print preview e Print setup e Exit Open Open an existing IRB image in the Analysis window Save Store the current image under the same name and in the same directory The existing file is overwritten Save as Save the current IRB image under a new name in a different format e g JPG BMP ASC and or under a different path gt The Save as window opens In the Save as window 1 Enter the filename and path 2 Click on Save gt The file is saved gt The display in the Preview area of the Exp
27. es Large thumbnails 160x120 pixels are displayed in the Pre view area See Section 6 3 3 View menu 21 22 FAL 6 3 6 3 1 Next palette Change color palette for the preview display toggle key The following palettes are used in a loop in this sequence from IRB VARIOCAM BlackWhite IronBow BlueRed MrkedBW Rainbow For an explanation of the palettes see Section 6 3 3 1 Settings Print preview Print the marked image in the Preview area VarioAnalyze opens a print preview window after again confirming the Windows print window See 6 3 1 9 Print preview For displaying or hiding the toolbar see Section 6 3 3 2 Toolbar Menu description in the Explorer window File menu The File menu has the following options e New root e Save e Save as e Send e New folder e Previous folder e Refresh directories e Print e Print preview e Print Setup e Exit 6 3 1 1 Fig 6 2 6 3 1 2 VarioAnalyze Explorer window New root Select a new directory which is to be displayed the next time the software starts as the default directory for thermo grams gt The Select root window opens Suchen in Gy Variodnalyze ef m EZ E Colours Doc _ J Images Abbrechen E Select root window The usual procedure for Windows Select path and click on open gt The displays in the Directory area and Preview area are u
28. etter templates e Own templates Select template x DIN A4 templates US letter templates Own templates Lk ee O eee ee Ju El ig CHT LJ E Fig 7 19 Select template window A4 templates tab 6 68 7 3 8 2 In the Select template window p Select the tab which corresponds to the format you want Click on the template you want gt The VarioAnalyze basic report window opens the template For editing and saving a report see Section 8 Create report Report window Open existing report Open existing report The report must previously have been stored in VarioAnalyze report format rep gt The Windows Open window opens In the Open window 1 2 Select path and filename Click on Open gt The report is opened in the VarioAnalyze basic re port window For editing and saving the report see Section 8 Create report Report window 1 3 9 7 3 9 1 7 3 9 2 Help menu The Help menu has the following options e Help e About VarioAnalyze Help Open VarioAnalyze Windows help About VarioAnalyze Display copyright information about the software and the version number of your copy of VarioAnalyze 69 70 7 4 7 4 1 Direct access with right mouse click The right mouse click on various objects of the Analysis window makes possible fast convenient access to func tions some of which c
29. ioAnalyze Basic lol x File Edit view Thermogram Measure Correction Extras Report Help SES gt afis labon R a mm N mo Mw G oers Change proporties for X1 a x Size Position El E iiy ee v Label position Name P all gt Ei Emissivity 1 00 ka Apply Delete VarioCAM head 40211001 IRB February 11 2004 VarioCAM Distance M Show minimum Iw Show maximum Absorption 0 00 76 000 H ll 24 000 mm Le Lu Les Las Le X1 49 27 0 4 27 32 567 C 25 408 c 62 163 c 5 87 C EE 280 68 30 309 C February 11 2004 10 4 VarioCAM 1 6 NUM Image in the Analysis window for editing a shape 3 Activate the Show minimum and or Show maxi mum options if the minimum and or maximum tem peratures within the shape are to be displayed 4 Contirm the settings by clicking on Apply To delete the selected shape Click on the Delete button in the Change properties tor shapename window gt The shape is removed Close the window by clicking on x VarioAnalyze Analysis window 7 4 2 Change limits and color palette To change the temperature limits and the color palette for your current thermogram in the Analysis window use the following function Click with the right mouse button on the temperature scale color scale in the Analysis window gt The Select limits and palette window opens Select limits and pa
30. lette j E Setup limits Select palette Direct Level 4 o gt 48 8 gemeng Min Max J Range H a gt 56 0 C Min Max selection Steps 256 D Calib range Apply invers C from irb x Fig 7 22 Select limits and palette window For the description of the options and settings in the Select limits and palette window see Section 7 3 4 1 Limits 73 74 7 4 3 Save print export thermograms Clicking with the right mouse button directly on the ther mogram of the Analysis window opens a flyout menu with these options Save As Save IRB files see Section 7 3 1 3 Save as Copy Copy the current window content to the Clipboard It is then possible to in sert it into other application programs Print Print the current image Selecting the function opens the Windows print win dow see Section 7 3 1 4 Print 8 1 Create report Report window Create report Report window The report function makes it possible to summarize the analysis and evaluation of your thermograms clearly and uniformly and to save them The Report window VarioAnalyze basic report opens after one of the two options in the Report menu of the Analy sis window Is called up Report Create new report or Report Open existing report See Section 7 3 8 Report menu Structure and function of the Report window The VarioAnalyze basic report window opens either a
31. lette in the colors of the rain bow Further options Next Display in the next color palette of the list 6 3 3 2 6 3 3 3 Invers Inverts the representation in the current color palette Thumbnails Select representation of the thermograms in the selected directory in the Preview area The following options are possible text only Thermograms will get shown with their filename date file type camera type and pixel resolution in a list form No preview images are shown Small display small Preview images large display large Preview images Sort by Sort the display in the Preview window Possible sort criteria e Filename e Filename reverse e File type e File type reverse e Time upward e Time downward Toolbar Display or hide VarioAnalyze Explorer toolbar For a description of the icons of the toolbar see Section 6 2 Toolbar in the VarioAnalyze Explorer window Status bar Display hide VarioAnalyze Explorer status bar 29 30 6 3 4 6 3 4 1 6 3 4 2 A check mark before the menu bar indicates whether the Status bar is displayed The status bar displays information in 5 fields of different sizes from left to right Field 1 e Description of the menu function which is currently marked if you move the cursor through the menus using the arrow keys of the keyboard e f available a description of the function of the printed icon in the toolbar e H an image is marked select
32. lorer win dow is updated only after the Refresh directories function has been executed see Section 6 3 1 7 Re fresh directories 7 3 1 4 Print Print the current image gt The Windows print window opens Alternatively you can reach this function by clicking on the thermogram with the right mouse button and choosing Print in the flyout menu In the Windows print window 1 Select printer and make settings for the selected printer 2 Click on OK gt The image is printed Print preview Print the current image in the current Analysis display win dow gt A print preview is opened 39 VarioAnalyze Analysis window GP 40211001 test irb YarioAnalyze Basic iol Sl YarloCAM head R1 181 86 296 1 46 40 5 C 273 C 746 C 1200 C Paget September 28 2005 12 Ivariocam 56 NUM Fig 7 2 Print preview for image printing in Analysis window Function buttons in the Print Preview window Print Start printing Next Page Change to next page only if there are multiple pages One Page Two Pages Display one page two pages simulta neously Zoom In Zoom into image enlarge representa tion Zoom Out Zoom out of image reduce representa tion Close Close print preview 40 7 3 1 6 7 3 1 7 To print the image 1 Click on Print gt The Windows print window opens 2 Select printer make settings for paper size orientation color options
33. m plate Delete page Delete current report page 81 82 8 2 3 8 2 3 1 8 2 3 2 8 2 3 3 View menu In the View menu you will find the following options e Next page e Previous page e Change the template Next page Display the next page in the open report Previous page Display the previous page in the open report Change the template Closes the current report if appropriate you have the option of saving the report Then opens the Select template window to select a new template see also Section 7 3 8 1 Create new report General procedure for image evaluation General procedure for image evaluation This section is intended to give you a brief overview of the flow of an image evaluation and presents the typical se quence of the individual steps A method of working which may differ from this is equally justifiable and may lead the user to the objective just as surely Also it will not be nec essary in all cases to carry out all the operations which are explained here Prerequisite The IR images are stored in one directory e g thermo grams on your system Image evaluation using VarioAnalyze 1 Start the VarioAnalyze software and select the directory with the stored thermograms e g thermograms See Section 5 1 Start program gt The VarioAnalyze Explorer window opens and shows the images which are held in the directory in the Pre view area
34. n empty report template or an existing report to be edited and saved Each template has predetined report elements text and graphic fields 75 Create report Report window e varioAnalyze basic report xj File Edit View J les VARIOANALYZE report 2 roum AN 11 2004 pc October 03 2005 13 05 Page 1 1 Fig 8 1 Report window Text field Enter text directly Graphic field Include images from the VarioAnalyze Analy sis window or from another file 76 8 1 1 Edit report fields Click with the left mouse button in the report field gt Ina text field the cursor flashes and you can write immediately gt Ina graphic field at first you see no reaction To insert a graphic use the Change properties of a report field function see following Section 8 1 2 Changing the properties of a report field and im porting images or the menu option View Copy to report 8 1 2 Changing the properties of a report field and importing images 1 Click with the right mouse button on the report field of which you want to change the properties gt The Setup report element property window opens Depending on whether the field is defined as a text or graphic field the relevant options can be selected 71 Create report Report window 78 Fig 8 2 Setup report element property 6 5 x Alignment Ze Text W multiline Ze left C Graphic center C right Font s
35. na lyzed are stored e lf thumbnails preview images of the images which are stored in the current directory are displayed e open the desired IR image in the Analysis window by double clicking on the preview image bire tye et Feines Fin Edt Ven Hap GE om sae a ac Im e 40511 OB a 4021100 Ra 401100 P February LL 2004 LOSE February LL D Lit Febuuen LL 2004 Li SE biia pii igi Ce pli GH a 40017 bih D P February LL ZOO LLI February LL ZO 1d February LL ZOOM LL iz 402711 DS Be February LL 2004 LL 1 Menu and icon bars 2 Directory tree 3 Preview image VarioAnalyze Explorer window Menu and icon bar For a description of the menus see Section 6 3 scription in the Explorer window 01 1006 Fal Fees LL 200M 10 4011004 ee February LL ZO 9 Menu de For a description of the icons see Section 6 2 Toolbar in the VarioAnalyze Explorer window 19 20 Directory tree In the left hand window area directory tree change the directory as for Windows Explorer by marking the desired folder Preview area In a similar way to Windows Explorer in the Preview area information about the objects which are held in the current directory images in the irb bmp und pcx formats is dis played Display options in the Preview area e Text list No preview images only text e Small preview images e Large preview images Double click
36. nt e Line e Rect e Circle e Ellipse e Polygon e Next e Previous Limits Define temperature limits and palette gt The Select limits and palette window opens Alternatively open the Select limits and palette win dow with a right mouse click on the temperature scale color scale in the Analysis window Select limits and palette RK x Setup limits Select palette Direct Level DH a gt 48 8 AT vv C Min Max 56 0 Range a D D Min Max selection Steps 256 Calib range Apply 7 invers C from irb Select limits and palette window Setup limits area Possible settings for the temperature scale Direct Specify temperature scale manually Define Level and Range using the 51 52 Min Max scrollbar or enter values in the input field Confirm and apply by clicking on Apply Temperature scale is defined by mini mum and maximum in the image Min Max selection Calib range From IRB The temperature scale is defined by minimum and maximum in the current selection area To use this function a selection must be marked To mark a selection area use the function 7 3 2 7 Set selection The calibration range of the camera is used as the temperature scale The cali bration range is encoded in the header of the IRB file Level and Range are set to the Same values as at the instant when the thermogram was taken using the camera
37. nt preview e Print e Exit 79 80 8 2 1 1 8 2 1 2 8 2 1 3 8 2 1 4 8 2 1 5 8 2 1 6 8 2 1 7 8 2 1 3 Open Open existing report Save Save the current report in VarioAnalyze report format rep The report which is saved in internal format can be edited again in VarioAnalyze at any time Save as Save current report Possible formats are REP VarioAnalyze internal format allows subsequent editing in VarioAnalyze HTML Web browser format subsequent edit ing in VarioAnalyze is not possible Save template as Save template in current design format rep Send Start email client if available open a new email and ap pend the current report to it as an attachment name re port rep Print preview Display print preview of current report Print Open Windows print window to print current report Exit Close Report window Before the current report is closed if appropriate you have the option of saving It 8 2 2 8 2 2 1 8 2 2 2 8 2 2 3 Edit menu In the Edit menu you will find the following options e Copy the page e Add page e Delete page Copy the page Save the current report in the Clipboard You thus have the possibility of inserting the report into oth er application programs e g Microsoft Word and to save it in their formats e g doc Add page Add a page to the current report The format of the new page is copied from the current te
38. nyms and rules are used Click Click with the left mouse button Right click Click with the right mouse button OK Identifies a button in a software win dow D Means the small cross in the top right corner of each window close window Menu Submenu 1 Submenu 2 Marks a path through the menus you follow it using either the mouse pointer or the arrow keys on the keyboard Edit correction definitions shapename Window name Instead of the expres sion in italics the actual name taken from your image in the example the shape name appears in the window Instructions for using this manual Application field of VarioAnalyze Application field of VarioAnalyze The VarioAnalyze software is used to manage analyze and evaluate infrared images thermograms In particular it is used for convenient analysis of thermograms which were taken using JENOPTIK thermal cameras Application field of VarioAnalyze Supplied items and system requirements Supplied items and system requirements The following are supplied e CD ROM with software for Windows operating systems as executable file e User manual The following are system requirements for installation and use of the software Operating system Windows 2000 Windows XP Free hard disk space Minimum 512 MB RAM Minimum 256 MB 512 MB or more recommended Processor clock frequency 1 GHz or higher Graphics card Windows 2000 or Windows XP com patible Minimum
39. on on the VarioAnalyze icon on your desktop or se lect the program in the Windows start menu e g Start All programs VarioAnalyze gt The Select root window opens 2 In the Select root window select the path to the de sired image directory e g directory thermograms and click on open gt The Explorer window of the software opens See the following section 5 2 Structure of the software user interface Depending on the number of drives which are con nected to the computer and the number of existing directories and subdirectories opening the Explorer window can take a few seconds Structure of the software user interface The VarioAnalyze user interface consists of two separate windows which remain open simultaneously e Explorer window to select directories and to display and select preview images Fig 5 1 e Analysis window to analyze thermal images and produce analysis reports Fig 5 2 Switching from the open Explorer window to the open Analysis window and vice versa is possible e g using the Windows standard key combination Alt Tab 15 Starting and ending the program 5 2 1 Fig 5 1 5 2 2 Fig 5 2 16 VarioAnalyze Explorer window BP C thermograms arioAnalyze ol x Fie Edit View Help 40211001 BMP 40211001 IRB 40211002 BMP 40211002 IRB February 11 2004 10 48 February 11 200
40. oo AJ Oh h P w M O BE i E ki A 1 25 8 25 8 25 7 25 7 25 7 25 7 22 7 25 5 22 7 25 5 25 6 25 7 25 7 fa 25 8 25 8 25 9 25 8 25 8 25 7 25 8 25 8 25 9 25 7 25 8 25 7 25 8 3 25 8 25 8 25 8 20 7 25 7 20 7 25 7 25 6 29 7 25 6 25 8 25 6 25 6 4 25 8 25 5 28 7 28 7 28 7 25 6 28 7 25 5 25 5 25 7 20 7 25 5 25 6 5 25 8 20 8 2 7 A 2 7 20 6 25 7 22 7 25 5 20 5 20 5 20 8 25 6 D 25 8 20 8 A 20 8 25 8 zur 25 8 20 7 20 6 zur 20 7 2 7 2 7 H 20 7 20 7 20 7 20 8 25 8 20 7 20 7 20 9 25 6 20 7 25 6 25 6 25 6 zl Temperature matrix window The window offers the following menu functions File menu Save as Print Exit Edit menu Copy Copy ASCII Mirror Rotate Save current temperature matrix as ASCII file Print current temperature matrix Close Temperature matrix window Store the current visble part of the tem perature matrix as image in the Clip board metafile Store current temperature matrix as text file in the Clipboard ASCII e g for im port into Microsoft Excel Mirror temperature matrix vertically horizontally Rotate temperature matrix left 90 right 90 180 7 3 4 5 Fig 7 10 7 3 4 6 VarioAnalyze Analysis window Isotherms Show isotherms You can define a maximum of 10 iso therms for each image gt The Isotherms window op
41. pdated Save Store the current image under the same name and in the same directory The existing file is overwritten Save as Store the current IRB image under a new name in a differ ent format and or under another path gt The Save as window opens In the Save as window 1 Enter the filename and path 23 6 3 1 4 6 3 1 8 24 2 Click on Save gt The file is saved gt The display in the Preview area is updated only after the Refresh directories function has been executed see Section 6 3 1 7 Refresh directories Send Send selected image by email gt Opens the email client and attaches the Tile to a new email To send it see your documentation for using your email program New folder Create new folder in Explorer Directory area Previous folder Change to the higher level folder Refresh directories Update the displays in the Directory and Preview areas Print Print the marked image in the Preview area gt The Windows print window is opened In the Windows print window 1 Select printer and make settings for the selected printer 2 Click on OK gt The image is printed VarioAnalyze Explorer window 6 3 1 9 Print preview af Print the marked image in the Preview area gt A Print Preview window is opened YarioAnalyze ms Page Prev Page Two Page Zoom In Zoom Gut Close CAMthermograms 4021 1001 IRB February 11 2004
42. py selection Copy the content of the selection area to the Clipboard The function is available only if a selection area is marked For marking a selection area see Section 7 3 2 7 Set selec tion The data from the Clipboard can be imported into other applications Copy measurement results Copy table with measured values as metafile graphic to the Clipboard The function is available only if measured values are dis played in the current view A measured value table is displayed if shapes ROI are de fined in the Analysis view using the Point Line Rect Circle Ellipse Polygon functions See Section 7 3 4 Thermo gram menu For copying the measured values as text ASCII see Section 7 3 2 5 Copy measurement results ASCII Copy measurement results ASCII Copy table with measured values as ASCII data text only to the Clipboard This copy function is particularly recom mended if the contents of the measured value table are to be evaluated or displayed using a spreadsheet program e g Excel Origin The function is available only if measured values are dis played in the current view A measured value table is displayed if shapes ROI are de fined in the Analysis view using the Point Line Rect Circle Ellipse Polygon functions See Section 7 3 4 Thermo gram menu For copying the measured values in graphic format meta data see Section 7 3 2 4 Copy measurement results
43. r ap pears below the mouse pointer 2 Using this crosshair pointer define horizontal and vertical axes for the temperature profile in the image and click on the desired position intersection point of the axes gt The temperature profile axes horizontal vertical are detined and displayed Comment Display hide image comment The comment which is stored in the image is displayed in the first cell below the IR image A check mark before the menu bar indicates whether the function Is activated 7 3 3 5 7 3 3 6 For changing editing the image comment see Section 7 3 2 11 Change comment Parameters Display hide image parameters The parameters are shown below the IR image below the comment line if any A check mark before the menu bar indicates whether the function is activated The following parameters can be displayed e Transmissivity e Emissivity e Filename e Time e Date e Ambient temperature e Camera e Zoom e Path temperature e Distance e Absorption For selecting changing the parameters see Section 7 3 7 1 Options Visible image Open Visible Image VIS in separate window This function is available only if a digital photo Visible Im age for the open IRB image exists The digital photo Visible Image VIS can either be stored in the IRB or exists as a bitmap BMP with the same name as the IRB in the same directory 49 50 7 3 3 7 7 3 3 8 Toolbar Displ
44. raredtechnology jenoptik com Internet www intraredtechnology de 85 Service und Support 86
45. revious image Emissivity Environment temp Transmissivity Path temp Options window Global Properties tab You can copy the following parameters from the previous image e Emissivity e Ambient temperature e Path temperature e Transmissivity 65 VarioAnalyze Analysis window 66 7 3 7 2 Fig 7 18 The marked parameters are not changed when a new IRB image is opened VarioAnalyze retains the associated values trom the previous image Arrange icons Display hide icons in the toolbar gt The Select toolbar icons window opens x V Open Iw Minimum Iw Temperature unit Iw Save as V Maximum Iw Audio IV Print Iw Point Iw Previous IV Line Iw Next Iw Rect IV Zoom Iw Circle V Zoom JV Ellipse IV Set selection Iw Polygon Iw Profile Iw Visible image Cancel Select toolbar icons window To display icons 1 Mark the icons which are to be displayed in the toolbar 2 Confirm with OK To cancel click on Cancel 7 3 8 Report menu The Report menu has the following options e Create new report e Open existing report 7 3 8 1 Create new report Create new report gt Select template window opens To create a report you can choose between predefined tem plates 3 A4 3 US letter formats and open your own previ ously stored templates tpl For preselection of templates the Select template win dow has 3 tabs e A4 templates e US l
46. tes the image by 90 to the left around its center Right 90 Rotates the image by 90 to the right around its center 180 Rotates the image by 180 around its center Filter Filter function to smooth the image and remove thermal noise The function always acts on the whole IR image Clean Filter function Image cleaning The function can be applied several times to optimize the cleaning Original Restore original image Change comment Edit image comment gt The Change comment window opens Change comment YariocAM head cancel Change comment window 45 46 To change the image comment P Click with the left mouse button in the text field mark text Enter new comment To confirm click on OK To cancel click on Cancel gt The changed comment is stored The current com ment is displayed in the Analysis window if the Comment function is active see Section 7 3 3 View menu 7 3 3 7 3 3 1 Fig 7 4 View menu The View menu has the following options e Show measurement results e Show temperature scale e Profile e Comment e Parameters e Visible image e Toolbar e Status bar Show measurement results Hide measured value table The measured value table is shown for each drawing of a shape ROI in the IR image under the thermogram under the displayed profile if any This table can be hidden using the Show measurement results
47. und Ho of most recently D used thermogramm Options window Generally tab 63 VarioAnalyze Analysis window The options have the following meaning Temperature presentation Number of digits after decimal point for measured temperature values Number of last used thermograms ROls font Font for the shape ROI name Comment font Font in the comment and parameter line Background Background color in the window Protiles background Background color for temperature pro file representation Parameters tab Select the parameters which are to be displayed in the pa rameter line Options Ce xi Generaly Parameter Global Properties Filename Date Camera Distance Env temp Absorption 4 Time Emisswriby oom Path temp Tranernssivity Fig 7 16 Options window Parameters tab The following parameters can be selected e Transmissivity e Emissivity e Filename e Time e Date 64 Fig 7 17 VarioAnalyze Analysis window e Ambient temperature e Camera e Zoom e Path temperature e Distance e Absorption Global Properties tab Copy properties from the previously opened image This option is useful for instance if you have recorded a series of measurements in approximately constant condi tions and want to correct all images of this series with the same parameters SS CC x Generally Parameter Global Properties Take properties from p
48. view area is active click with left mouse button in the Preview area or if one or more images are marked there Image sequence Function to show only the selected marked images 1 Mark desired images in Preview area with Shift click or Ctrl click 2 Select menu Edit Image sequence gt Only the selected images are displayed in the Preview area Change comment Change the image comment for the selected IRB image The image comment can be displayed in the Analysis win dow see Section 7 3 2 11 Change comment 27 28 6 3 3 6 3 3 1 FAL View menu The View menu has the following options e Settings e Toolbar e Status bar Settings Select properties for the display in the Explorer window Palette for IRB Select color palette for the Preview display The following palettes can be selected from IRB Representation of the IR image in the color palette which is encoded in the IRB file IRB is the color palette with which the thermogram was originally taken by the camera VARIOCAM Representation in the color palette of the VarioCam BlackWhite Gray scale representation IronBow Color palette in the tempering colors of steel BlueRed Color palette from blue low tempera tures to red high temperatures MrkedBW Marked Black White Color palette in gray scale representation with color marking of high temperatures red and low temperatures blue Rainbow Color pa
Download Pdf Manuals
Related Search
Related Contents
Sony PMW-200 Installation Instructions SEH PS23a rapport - webwww03 - poseidon.heig Andis Company AGR+ User's Manual Sarajevo pour les débutants B64-3347-00_French r3.Indd Consultez la première INFOLETTRE PZDシリーズ取扱説明書ダウンロード Copyright © All rights reserved.
Failed to retrieve file