Home

BD-503 Neutrality OPM User Manual V1.0_NO cover

image

Contents

1. reference value Backlight is on when turning on the unit it would auto turn off 1 minute later You could press any key to turn it on for 1 minute again Operation Turn on off Press ON OFF shortly to turn on the unit press it for a few seconds to turn it off and click it to activate or deactivate the auto off function Absolute power measurement Connect the power meter with optical signal Turn on the power meter Choose the correct wavelength via A key If the tested wavelength is not exactly same to the one in the power meter then choose a 11 www komutacija com Optical Power Meter SD 503 lt gt 7 4 close one from the power meter Press dBm W to choose the display unit the default wavelength is 1310nm and working mode is dBm Then the power meter will show the test power value Relative power test Set wavelength Press dB for 2 seconds to enter the relative test mode now LCD screen display 00 00dB Connect it to the test signal the current value is difference between the tested value and reference value Reference value is in the Ref position Press dBm W to review the current absolute power value Press dB to review the current reference value User self calibration function ON ON E MM i 2 1 2 amp lf calibration ition Work position www komutacija com Optical Power Me
2. AAA batteries DC Optional accessory AC working range is AC90 240 Working hours gt 120 hours without backlight weight g 160g dimension mm 125x65x29 T www komutacija com Optical Power Meter SD 503 4 1 2 3 4 5 5 1 2 3 4 5 6 7 Standard Accessories power meter 1 pouch Viatri cin 1 MANUAL tamme 1 battery AAA transportation permit 3 certificate gt veias tea decia iras 1 simply operation ON OFF press it for a few seconds to turn it on off click to turn on off back light switch the wavelength dB press 2 seconds to enter the relative measurement mode dBm W press it to enter the relative measurement mode Replace the battery when the power is low Take out the battery when not in use for a period of time Refer to the back label for operation www komutacija com Optical Power Meter SD 503 6 Appearance and function 6 1 LCD Screen cana interface Model Wavelength unit value battery level z Auto off ON OFF Wavelength REF select Relative power dBm w Test Optical Power Meter absolute power test Wavelength display the wavelength such as 850nm 1300nm 1310nm 1490nm 1550nm and www komutacija com Optical Power Meter SD 503 1625nm Power value lt gt it displays the current output power under absolute test mode it displays the difference between the current output po
3. e out the battery when not in use for a period of time 9 Problems Problem Reason Solution Faint LCD Lower power Replace the battery screen No backlight Lower power Replace the battery No display Lower Turn on again or when turning on power other replace battery Fail to turn on Lower power Replace the battery No changing on Lower power Replace the battery LCD screen In sensitive Dirty or Use the correct LCD screen polluted connector and clean connector it www komutacija com Optical Power Meter SD 503 10 Warranty notice Warranty Period It is within 18 months from the date of purchase Warranty clause Under the warranty we would repair the problems caused under the normal operation free of charge Note remember to show us the warranty card when repair For the following situation we have to charge certain cost 1 Out of the warranty 2 Fail to provide the warranty card 3 alter and omit the warranty card 4 Wrong operation including the problem caused by human actors abnormal working environment and so on 5 Problems or damages are not caused by the products quality 6 Do not operate it according to this manual For the following situation we do not repair it 1 Damaged seal label 2 Take apart it without our agreement 3 Other companies products www komutacija com Optical Power Meter SD 503 Quality certificate Product name
4. handheld optical power meter Product model Serial number Date of production Inspection Warranty card Date of purchase Customer name Customer address Customer phone Distributor name Distributor phone Posted back to
5. ter SD 503 lt gt gt PN 7 5 Take out the battery and pull up the switch 1 to ON position Put the battery back to the battery compartment and turn on the unit to choose the wavelength for calibration Now connect it with pigtail and press REF or dBm W to increase or decrease the data by 0 05dB When the value is same to the one in the standard power meter or lower 0 03dB press on OFF to save the changed result Repeat above operation for other wavelength After recalibrate each wavelength please pull down the switch 1 come back to the position the opposition of the ON and turn off the meter End the user self calibration operation Auto off function The auto off is on when turning on the unit Press ON OFF to activate or deactivate it 7 6 PS lt gt lt gt Replace battery If the battery level is very low please turn off the unit immediately and replace the batteries Take out the battery 1f not in use for a period of time NOTE do not charge the non rechargeable battery dangerous 13 www komutacija com S Maintenance Optical Power Meter SD 503 1 keep all optical connectors and surfaces free from oil dirt or other contamination to ensure proper operation 2 Keep using the same type of connector 3 Please cover the dust cap when not in use to keep the connector clean 4 Carefully plug in or out the adapter 5 Regularly clean the connector 6 Tak
6. wer and reference power under relative test mode Unit mW uW nW dBm dB Relative test press dB to start relative test Auto off activate the 10 minute auto off function Battery level real time indicate the battery level When blank it indicates the power is too low 6 2 Function 1 ON OFF click ON OFF to turn it on press for 3 seconds to turn it off Under power on mode press this key shortly to activate or deactivate the 10 minute auto off function 2 dBm W press dBm W to enter absolute test mode Press it again to switch the test unit 3 NM switch the wavelength from 6 calibrated wavelength 4 dB press dB key once to enter relative test and it has 3 working mode A directly enter the relative test under absolute test press this key to enter the relative test now the Ref value shows the previous power values www komutacija com Optical Power Meter SD 503 5 SI N gt lt B Reference value storage when enter the relative test press dB for 2 seconds to save the current absolute power value as REF value and show the relative power value in dB unit c Enter the relative test and save current reference value under the absolute test mode press dB for 2 seconds to enter the absolute test mode and save the current value as reference value which is showed in Ref position Now the value in dB unit on the screen is the difference between the real test value and
7. wer meter manual SD 503 www komutacija com Optical Power Meter SD 503 1 Model A measurement range 70 10dBm calibrated wavelength 850nm 1300nm 1310nm 1490nm 1550nm 1625nm B measurement range 50 26dBm calibrated wavelength 850nm 1300nm 1310nm 1490nm 1550nm 1625nm 2 gt gt rs 4 Features High measurement accuracy and display resolution Quick response and measurement when power changing it can track and real time display the output power Wide measurement range 80dB range Six calibrated wavelength 850nm 1300nm 1310nm 1490nm 1550nm and 1625nm other wavelength could be provided on request Absolute and relative measurement Real time monitoring and displaying the battery level Auto off function Backlight function Alkaline battery www komutacija com Optical Power Meter SD 503 lt gt User self calibration function 3 Specifications Measurement 70 10 dBm 50 26 dBm range dBm Other range is on request Wavelength 800 1650 range nm 850nm 1300nm 1310nm nn 1490nm 1550nm 1625nm wavelength optional other wavelength Detector InGaAs Accuracy lt 3 10dBm 22 C Linearity 0 1 Non linearity Resolution 0 01dBm Working 10 C 50 C temperature Storage 20 C 70 C temperature Relative 90 30 C humidity connector Movable FC PC optional ST SC Power supply 3pcs
8. www komutacija com Optical Power Meter SD 503 CONTENTS 1 Model 6 2 Features cnn 6 3 Specifications 7 4 Standard Accessories 8 5 simply operation 8 6 Appearance and function 9 6 1 LCD Screen 9 6 2 Function 10 7 Operation 11 7 1 Turn on off 11 7 2 Absolute power measurement 11 7 3 Relative power test 12 7 4 User self calibration function 12 7 5 Auto off function 13 7 6 Replace battery 13 8 Maintenance 14 9 Problems 14 10 Warranty notice 15 www komutacija com Optical Power Meter SD 503 WARNING Security rules To protect the instrument from being damaged do not use under the high temperature high pressure wet or other prohibited condition Do not personally take apart or repair the instrument Quality assurance We assure that each unit meets the declared specification Notice Technical Parameter is subject to change without notice www komutacija com Optical Power Meter SD 503 Handheld optical po