Home
Networking
Contents
1. 10Base T 100Base TX 1000Base T Gigabit Ethernet ports Supports Auto MDI MIDX and Auto Negotiation Supports 10Base T Category 3 4 or 5 TP Supports 100Base TX 1000Base T Category 5 gt 5e TP or higher Transfer Mode Store and Forward Packet Buffer Size 2Mbits MAC Address Table 8K entry lookup table 10BASE T 10 20Mbps half full duplex Bandwidth 100BASE TX 100 200Mbps half full duplex 1000BASE T 2000Mbps full duplex Forwarding Filtering Rate 14881 packets second per port 10Mbps maximum 148810 packets second per port 100Mbps maximum 1488095 packets second per port 1000Mbps maximum Switch Fabric 32Gbps Jumbo Frame Supports maximum 9216bytes packet length Green Ethernet Link On and Cable Length Power Saving Link Down Power Saving IEEE 802 3az Energy Efficient Ethernet EEE Miscellaneous LED Indicators Power Loop x 1 Port Link Act Loop x 16 Operation Requirement http www sapido com tw 9 Operating Temp K 0 to 40 4 A 32 to 104 Storage Temp 4 K 20 to 70 K 4 to 158 Operating Humidity 10 to 85 Non Condensing Storage Humidity 5 to 90 Non Condensing USER MANUAL V1 0 Power Supply Dimensions AC100 240V 50 60Hz universal input 250 L x 148 8 W x 43 H mm http www sapido com tw 10 USER MANUAL V1 0
2. not be disposed of with household waste This mark is based on European Directive 2002 96 EC for Waste Electric and Electronic Equipment WEEE Please take it to the designated collection facilities We will ensure the proper recycling reuse and other forms of recovery of WEEE WEEE has the potential effects on the environment and human health as a result of the presence of hazardous substances You can contribute to eliminate these effects by your cooperation http www sapido com tw 4 USER MANUAL V1 0 1 Getting to know the Switch 1 1 Introduction The Gigabit Ethernet Switch is equipped with 16 Gigabit copper ports and each port provides a max speed of 2000Mbps and a Full Duplex Collision Free Bandwidth It s a multi speed versatile network device that combines Gigabit Fast Ethernet and Ethernet ports in a single device This device meets ROHS compliance It is power saving with Green Ethernet technology 1 2 Key Features Supports Auto Negotiation on each TP port Supports 9216byte maximum packet length Supports Green Ethernet Link On and Cable Length Power Saving Link Down Power Saving IEEE 802 3az Energy Efficient Ethernet EEE supported Provides Store and Forward switching scheme Supports Auto MDI MDI X function Supports IEEE 802 3x Flow Control for Full Duplex operation Back Pressure function supports for Half Duplex operation Non Blocking Performance Improves Access to Network Resources 8K entry look
3. required to take adequate measures National Restrictions Frequency range 2400 0 2483 5 MHz Country Country Reason remark General authorization required for outdoor use Bulgaria none i g and public service Military Radiolocation use Refarming of the 2 4 GHz band has been ongoing in recent years to allow current relaxed regulation Full implementation planned 2012 Outdoor use limited to 10 France mW eir p within the band 2454 2483 5 MHz If used outside of own premises general authorization is required General authorization required for network and service supply not for spectrum Italy none Luxembourg none This subsection does not apply for the Norway Implemented geographical area within a radius of 20 km from the centre of Ny Alesund Russian Federation none Only for indoor applications Note Please don t use the product outdoors in France CE Statement of Conformity Our product has been tested in typical configuration by Ecom Sertech Corp and was found to comply with the essential requirement of Council Directive on the Approximation of the Laws of the Member Sates relating to Electromagnetic Compatibility 89 336 EEC 92 31 EEC 93 68 EEC The Declaration of Conformity can be found at the Sapido regional website www sapidotech de CE Information of Disposal pee TI tric and electronic equipment or unit which is labeled with crossed out wheeled bin may
4. Saqido One for all Gigabit Switch 16 Port Green Gigabit Switch User Manual v1 0 0 __ TABLE OF CONTENTS 1 GETTING TO KNOW THE SWITCH 1 1Introduction 1 2Key Features 1 3The Front Panel 1 3 1Network Ports 1 3 2Cabling 1 3 3LEDs status 1 4The Rear Panel 1 4 1Power Connector 2 USEFUL TIPS 2 1Prior to Installation 2 2 Half and Full Duplex 2 3 Auto Negotiation 3 PRODUCT SPECIFICATIONS NNN N OO OO OO O1 O1 O1 a a A http www sapido com tw 2 USER MANUAL V1 0 FCC Statement FE Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver
5. e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help FCC Caution 1 The device complies with Part 15 of the FCC rules Operation is subject to the following conditions 2 This device may not cause harmful interference and this device must accept any interference received including interference that may cause undesired operation 3 FCC RF Radiation Exposure Statement The equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body 4 This Transmitter must not be co located or operating in conjunction with any other antenna or transmitter 5 Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment IMPORTANT NOTE FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance20cm between the radiator amp your body http www sapido com tw 3 USER MANUAL V1 0 CE Mark Warning CEN This is a class B product In a domestic environment this product may cause radio interference in which case the user may be
6. ing mode by using their Auto Negotiation function 2 3 Auto Negotiation Every 10 100 1000Mbps port on the switch has a built in Auto Negotiation function This technology allows each port to automatically sense and set the best possible speed as soon as a connection with another network device is established usually at Power On or Reset Evaluating Auto Negotiation Capability if attached device is The switch will automatically set its TP ports to operate at 1000Mbps 2000Mbps 1000BASE T Full Duplex with Auto Negotiation Note Almost all 1000Mbps devices only operate in Full Duplex mode http www sapido com tw 7 USER MANUAL V1 0 100Mbps 100Mbps 100BASE TX Half Duplex no Auto Negotiation 100Mbps 200Mbps 100BASE TX Full Duplex with Auto Negotiation 10Mbps 10Mbps 10BASE T Half Duplex no Auto Negotiation 10Mbps 20Mbps 10BASE T Full Duplex with Auto Negotiation Note If the attached device is set to a fixed mode ex Forced Full Duplex it will not operate as an Auto Negotiation device http www sapido com tw 8 USER MANUAL V1 0 3 PRODUCT SPECIFICATIONS Item Specification Key Components Realtek RTL8376 16 port Gigabit switch controller Chipset Realtek RTL8218 8 port Gigabit PHY Ethernet Interfaces IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX Fast Ethernet Standards IEEE 802 3ab 1000Base T Gigabit Ethernet IEEE 802 3x Flow Control Ethernet Port 16 x
7. switch and connecting network devices it is important to plan the network s layout Things you should consider include Dedicated Bandwidth File servers and other high traffic hardware will have better and improved performance if they have their own dedicated 10Mbps 100Mbps or 1000Mbps bandwidth Full Duplex Determine which devices support Full Duplex connections Fast Ethernet amp Gigabit Ethernet Make sure rules for cable lengths and categories are followed 100BASE TX and 1000BASE T have the same rules for cable and distance Auto Negotiation Devices with different speeds may be easily swapped when the other end of the cable is fixed to a port with Auto Negotiation 2 2 Half and Full Duplex The switch supports both Half and Full Duplex modes for 10BASE T and 100BASE TX But the 1000BASE T only supports Full Duplex mode In Half Duplex mode Data cannot be transmitted and received at the same time Attached devices must finish transmitting data before they can receive data In Full Duplex mode Data can be transmitted and received at the same time However Full Duplex transmission is only possible between two devices with a dedicated link e g Switch Switch Switch PC Both devices must have Full Duplex capability Both devices must be set to Full Duplex e g Auto Negotiation Auto Negotiation Non Auto Negotiation to Non Auto Negotiation The 10 100 1000Mbps ports on the switch detect and set the line s operat
8. up MAC address table 1 3 The Front Panel 1 3 1 Network Ports The Switch is equipped with eight RJ 45 ports that support network speeds of 10 100 1000Mbps 1 3 2 Cabling 1000Mbps To transmit at 1000Mbps requires Cat 5 TP cabling that has all Four 4 twisted pair wires connected in RJ45 connector 100Mbps To transmit at 100Mbps requires Cat 5 cabling 10Mbps When transmitting at 10Mbps Cat 3 4 or 5 TP cabling with RJ 45 sockets can be used http www sapido com tw 5 USER MANUAL V1 0 Port Type Cable Type Connector 1000BASE T Cat 5 TP RJ 45 100BASE TX Cat 5 TP RJ 45 10BASE T Cat 3 4 or 5 TP RJ 45 Note Cat 5 TP cable recommended whenever installing new cabling 1 3 3 LEDs status Information about the Switch s activity is displayed through its LEDs shown as below Green On Power is being applied to this product Power indication Power x1 and loop status Red EAS Loop is detected On Connected at 1000Mbps Orange nking 1000Mbps Tx Rx activity or loo Ethernet port 30ms7 detected p Port x 16 aati Ano loop u On Connected at 10 100Mbps Green linking 0 100Mbps Tx Rx activity 1 4 The Rear Panel 1 4 1 Power Connector The power connector is designed to be used with the power adapter included in the product package http www sapido com tw 6 USER MANUAL V1 0 2 Useful Tips 2 1 Prior to Installation Before installing the
Download Pdf Manuals
Related Search
Networking networking networking events near me networking definition networking and sharing networking basics networking devices networking events networking jobs networking layers networking images networking tools networking questions networking fundamentals networking synonym networking academy networking and sharing center networking groups near me networking protocols networking certifications networking academy cisco networking pdf networking essentials networking cisco networking linux networking significado
Related Contents
Module type Controller(CC-Link) Philips Savvy TCD138 User's Manual Tedious Task Manager (TTM) User Manual 特 徴 使用上の注意 付属品 仕 様 製品前後図 アーガス アーガス アーガス Coby MP620 Draytek Vigor2700e ADSL2+ Wi-Fi Ethernet LAN Black, Blue Solac Springtec Parquet AB2722 47231モジュールライトベースライト_A [Converted] SUDOKU EXPERT - Millennium 2000 Copyright © All rights reserved.
Failed to retrieve file