Home

BIOPAK240 REVOLUTION™

image

Contents

1. The Scott BioPak 240 Revolution was developed with direct input from the people who put their lives on the line doing their jobs We relied on their ideas throughout our design engineering and field testing phases As a result the BioPak 240 Revolution rebreather offers easier breathing better ergonomics enhanced safety faster deployment and lower service costs APPLICATIONS INCLUDE Trench Tunnel Rescue HAZMAT Teams Domestic Preparedness Response Homeland Security Issues Power Plant Emergencies WM D Counter Terorism Operations Search Rescue and Recon Urban Search amp Rescue Confined Space Situations Building Collapse Search Special Operations Bomb Squads SWAT Teams ORDERING INFORMATION FOR BIOPAK 240 REVOLUTION REBREATHER BioPak 240 Revolution Rebreather and Facepiece Ordering Information Part Number Description 7 07 2401 02 0 NIOSH Certified Flame Rated Harness Green O2 Cylinder S7 07 2401 04 0 NIOSH Certified Standard Harness Green O2 Cylinder 6 02 5002 09 0 NIOSH AV 3000 Facepiece Small S6 02 5002 09 1 NIOSH AV 3000 Facepiece Medium S6 02 5002 09 2 NIOSH AV 3000 Facepiece Large Respirator Top Assembly includes 1 Respirator Assembly 1 Facepiece Anti Fog Spray 1 Monitor System 9V DC Battery 1 User Manual English 1 Benchman User English 2 Ice Canister Freeze Forms with Ice Canisters installed All packaged into a cardboard foam shipping car
2. BIOPAK 240 REVOLUTION STATE OF THE ART 4 HOUR REBREATHER SCOTT HEALTH amp SAFETY THE BIOPAK 240 REV REVOLUTIONARY 4 HOUR REBREATHER FOR The Scott BioPak 240 Revolution Rebreather was developed to protect first responders who put their lives on the line in long duration dangerous and demanding conditions Whether it s a collapsed building tunnel rescue industrial accident HAZMAT clean up or urban search and rescue operation the BioPak 240 helps those who serve and protect to do a better safer job The innovative BioPak 240 Revolution is the most highly advanced easiest to use 4 hour rebreather With 6 liters of tidal volume it delivers the lowest resistance breathing of any rebreather available today The BioPak 240 Revolution cuts return to service time by 50 A revolutionary solid scrubber design eliminates the need to measure and refill COz absorbent as well as potential for refilling errors Easy Breathing High volume low resistance breathing means more comfort and less stress Lowest closed circuit breathing resistance available at all work rates with 6 liters of tidal volume e Large breathing chamber uses three springs for guaranteed positive pressure e Vents only used air reducing O2 and demand valve usage Rapid Deployment Revolutionary solid COz scrubber design enables a super fast deployment e New quick change cooling system lets personnel return to the job faster e Cuts
3. e latches Easy to remove breathing chamber e Threaded positive cylinder connection Tough Rugged Construction To withstand the most rugged use the 240R s housing features stainless steel fiber reinforced polymer construction The simplified internal plumbing design reduces pneumatic tubing and connections dramatically improving reliability and reducing overall weight A positive connection between air cylinder and valve assures correct alignment and a secure connection All hoses housing facepiece and outside materials are made of flame rated materials e Stainless steel fiber reinforced polymer construction Reduced tubing and connections All electronics are internal Flame tested components Material selected for electromagnetic immunity TO MAINTAIN HEN AND WHERE YOU NEED 1 EE New Challenges Demand New Solutions Tragic events such as building and bridge collapses as well as the potential devastation caused by the threat of WMD and CBRN weapons present complexities of response for today s first responders Fire service EMS and law enforcement personnel are called upon for immediate and coordinated efforts and they demand reliable life saving equipment to complete their missions in a safe and effective manner The 240R represents the most significant advancement in closed circuit breathing apparatus technology in over a decade and offers extended duration respiratory protection for the most unpredictable situations
4. formance Three exclusive Comfort Seal sizes and a nosecup uniquely designed for comfort put the ease of fit testing and wearing the AV 3000 Facepiece in a class by itself With a four point adjustable head harness and optional dual adjustment spectacle kit donning and doffing is quick and easy And no 21st century facepiece is complete without state of the art communications The AV 3000 Facepiece features large dual voicemitters for clearer communications and dual mounting brackets that allow for communication interface on either side of the facepiece An optional magnetic facepiece lens wiper promotes internal and external surface wiping with a single pass with no pass throughs required to operate the wiper RESPOND WITH CUT WHAT ELSE WOULD YOU EXPECT FROM THE With patented cutting edge technology and state of the art safety and performance the Scott BioPak 240 Revolution represents the most significant advancement in closed circuit self contained breathing apparatus technology in over a decade Quick Change Cooling System The quick change cooling system allows you change out the cooling canisters while the unit is being worn without breaking the breathing loop or removing the external housing Designed for improved safety developed for reliability this revolutionary new breathing apparatus will out perform any other unit on the market Simply twist off the externa
5. l lids swap out frozen canisters and replace the lids Faster Easier Scrubber Refresh BioPak 240R s patented and unique scrubbers feature solid absorbent packaged in disposable cartridges They are easier to replace than granular absorbent which requires precise measuring refilling and resealing of a canister The 240R s solid absorbent cartridges make for faster deployment They will not channel dust or settle during usage or transportation and they eliminate the potential for refilling errors TING EDGE TECHNOLOGY LEADERS IN SCBA S Enhanced Ergonomic Design With alow profile body contoured design the BioPak 240 Revolution is very comfortable to wear and simple to use with all controls and displays easily accessible Slim profile can be comfortably worn under protective gear without restricting movement Fully padded ergonomic harness positions the unit on the hips instead of the shoulders reducing operator fatigue Harness can be easily adjusted to fit Moisture generated within the system during use is retained limiting the amount reaching the facepiece Designed For Improved Safety The BioPak 240R gives the user every safety advantage Stainless steel fiber reinforced housing provides for a mechanically and electronically robust design Hardened breathing chamber Bump proof knob prevents accidental O2 cylinder actuation M anual quick disconnect prevents O loss if the gauge line is damaged Elect
6. return to service time by up to 50 Change out cooling canisters while unit is being worn without breaking into the breathing loop or removing the external housing e Eliminates manual measuring and refilling of granular CO2 absorbent Greater User Safety and Comfort Designed to keep personnel safer more comfortable and fully aware of operational status Optical warnings for low battery coolant installation status and 2596 to end of service Radio interference shielding Lighter weight more comfortable to wear Flame rated harness available OLUTION DEMANDING APPLICATIONS Large breathing chamber incorporates three springs for guaranteed positive pressure Vents only used air reducing overall oxygen need and demand valve usage Sensor monitor reminds user if frozen coolant canisters have not been installed prior to use Easy to replace disposable solid CO2 absorbent Pneumatic pressure gauge displays O2 status Alarm sounds when oxygen supply reaches 25 to end of service Easy to use bump proof knob prevents accidental cylinder actuation Fiber optic warning signals normal operation low battery possible missing cooling canisters and 25 to end of service SEE YOUR WAY CLEAR THE AV 3000 FACEPIECE The BioPak 240R features the inventive Scott AV 3000 Facepiece This sleek low profile facepiece provides better downward and peripheral vision to improve safety and job per
7. ronic alarm sounds when the supply reaches 25 of service life Flame rated harness available hk hk CONTINUAL USER FEEDBACK The BioPak 240R keeps the user completely aware of unit status and oxygen supply Temperature sensor alerts user to check if coolant canisters were installed at start up Audible alarm for low O2 and battery Pneumatic pressure gauge monitors O2 status and sets off alarm at 25 of service life LED warning display in the gauge housing provides color coded alerts for normal operation low battery possible lack of coolant canister installed and 25 to end of service Alarm Condition Status OK Insert Coolant Canister EASY TO OPERATE EASY FOR EXTENDED DURATION PROTECTION W Less Expensive To Own The BioPak 240 Revolution is designed to deliver lower cost extended reliability and easy maintenance The 240R has a lower initial purchase price costs less to maintain and provides a lower total ownership cost than any other closed circuit positive pressure four hour rebreather No mandatory replacement parts or factory rebuilds are required for the life of the unit Lower initial purchase price Lower maintenance costs Lower total cost of ownership The BioPak 240 Revolution features fewer parts for quick servicing Service access is simplified with an easy to operate latch system and easy to remove breathing chamber Easy to operat
8. ton BioPak 240 Revolution Rebreather Accessories and Supplies Part Number Description B5 01 5000 00 0 Carbon Dioxide Scrubber B6 02 5002 63 0 Hard Carrying Case B6 02 5002 16 0 Service Test tool kit B6 02 5000 42 0 Disinfectant Carton of 75 B2 02 7000 39 0 Soft Carrying Case Specifications Weight 33 Ibs 15 kg Dimensions 23 0 L x 17 3 W x 7 0 D 584mm X 439mm X 178mm Cylinder 4401 3000 psig 207 M edical Aviation grade O2 Duration 4 hours 240 mins Certified Contents BioPak 240 Revolution Unit Scott AV 3000 Facepiece ordered as a separate line item to indicate size of facepiece needed Cooling Canisters 2 Anti Fog Solution e Users Manual e Benchman s Manual Approvals NIOSH e MSHA EN 145 136 Scott Health amp Safety is a global business unit of Tyco International that supplies a variety of industries through manufacturing facilities located in the United States United Kingdom Asia Finland and Australia Monroe Corporate Center 569 Monroe NC 28111 Telephone 800 247 7257 Facsimile 704 291 8330 www scotthealthsafety com sh sale tycoint com H S 6693A 10 08 ISO 9001 Registered All rights reserved BIOMARINE NEUTRONICSM BioPak 240 Revolution is a trademark of Biomarine Inc t REBREATHERS Title Sponsor SCOTT FTE TS PC HEALTH amp SAFETY

Download Pdf Manuals

image

Related Search

Related Contents

PL855 Manual  LES JEUNES ET INTERNET - Ministère de la Culture et des  Mebius Turn 半自動リバース制御装置 MBS2500 取扱説明書  Remote Control Quick Reference Guide Guía de Referencia Rápida  A USER`S MANUAL  グロウジェクトBC 注射用8mg  Zoku ZK107 ice cream maker  Installation Instructions  T14LCID- User Manual  Baracoda RS232  