Home

Red Lion Controls DSPLE000 Datasheet

image

Contents

1. Bulletin No DSPLE B Drawing No LP0671 CONVERTS NUMEROUS PROTOCOLS SIMULTANEOUSLY EXTENSIVE BUILT IN DRIVER LIST ALLOWS EASY DATA MAPPING TO PLCs PCs AND SCADA SYSTEMS 10 BASE T 100BASE TX ETHERNET PORT SUPPORTS FOUR SIMULTANEOUS PROTOCOLS INDEPENDENT SERIAL PORTS PROVIDE VIRTUALLY UNLIMITED INTEGRATION METHODS SUPPORTS UP TO NINE PROTOCOLS SIMULTANEOUSLY with expansion card SAFETY SUMMARY All safety related regulations local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Do not use the controller to directly command motors valves or other actuators not equipped with safeguards To do so can be potentially harmful to persons or equipment in the event of a fault to the controller An independent and redundant temperature limit indicator with alarm outputs is strongly recommended CAUTION Risk of Danger Read complete instructions prior to installation and operation of the unit A WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS DIVISION 2 THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS DIVISION 2 GROUPS A B C D OR NON HAZARDOUS LOCATIONS ONLY A A Compa
2. Figure 1 Attach Data Station To DIN Rail 1 00 min clearance LEDS USER COMMUNICATION PORTS TX RX LEDS STS STATUS LED The green Status LED provides information regarding the state of the Data GREEN Transmitting Station This includes indication of the various stages of the start up routine Note LEDs are not available on the Programming Port RS232 PG Startup Routine s H INDICATION Data Station is currently running the boot loader and or ETHERNET LEDS being flash upgraded by Crimson Rapidly Flashing LED INDICATION Steady Data Station is operating properly YELLOW Solid Link Established YELLOW Flashing Network Activity CF COMPACTFLASH LED GREEN 10 BASE T Communications Off No CompactFlash Card is present Steady Valid CompactFlash card is present AMBER 100 BASE TX Communications Flashing Rapidly CompactFlash card is being checked Unit is writing to the CompactFlash either because Flickering it is storing data or because the PC connected via the USB port has locked the drive i Flashing Slowly Incorrectly formatted CompactFlash card present 1 Do not turn off power to the unit while this light is flickering The unit writes data in two minute intervals Later Micros
3. ETIC COMPATIBILITY Emissions and Immunity to EN 61326 Electrical Equipment for Measurement Control and Laboratory use Immunity to Industrial Locations Electrostatic discharge EN 61000 4 2 Criterion A 2 4 kV contact discharge 8 kV air discharge Electromagnetic RF fields EN 61000 4 3 Criterion A 10 V m Fast transients burst EN 61000 4 4 Criterion A 2 kV power 2 kV signal Surge EN 61000 4 5 Criterion A 1kV L L 2 kV L amp N E power Criterion A RF conducted interference EN 61000 4 6 3 V rms Emissions Emissions EN 55011 Class A Notes 1 Criterion A Normal operation within specified limits 2 This device was designed for installation in an enclosure To avoid electrostatic discharge to the unit in environments with static levels above 4 kV precautions should be taken when the device is mounted outside an enclosure When working in an enclosure ex making adjustments setting jumpers etc typical anti static precautions should be observed before touching the unit 11 WEIGHT 15 1 oz 456 4 g WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR AREA IS KNOWN TO BE NON HAZARDOUS HARDWARE INSTALLATION DIN rail should be mounted horizontally so that the unit s ventilation holes are vertical in relation to cabinet orientation A minimum clearance of 1 inch 25 4 mm should be maintained above and below the unit in order to ensure proper thermal regulation
4. ctFlash is a registered trademark of CompactFlash Association SPECIFICATIONS 1 POWER 24 VDC 10 200 mA min without expansion card 1 Amp maximum with expansion card fitted Must use Class 2 or SELV rated power supply 2 COMMUNICATIONS USB PG Port Adheres to USB specification 1 1 Device only using Type B connection WARNING DO NOT CONNECT OR DISCONNECT CABLES WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE NON HAZARDOUS USB PORT IS FOR SYSTEM SET UP AND DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT CONNECTION Serial Ports Format and Baud Rates for each port are individually software programmable up to 115 200 baud RS232 PG Port RS232 port via RJ12 COMMS Ports RS422 485 port via RJ45 and RS232 port via RJ12 DH485 TXEN Transmit enable open collector Voy 15 VDC Vor 0 5 V 25 mA max Ethernet Port 10 BASE T 100 BASE TX RJ45 jack is wired as a NIC Network Interface Card 3 LEDs STS Status LED indicates condition of Data Station TX RX Transmit Receive LEDs show serial activity Ethernet Link and activity LEDs CF CompactFlash LED indicates card status and read write activity 4 MEMORY On board User Memory 4 Mbytes of non volatile Flash memory On board SDRAM 2 Mbytes Memory Card CompactFlash Type II slot for Type I and Type II cards Used for optional database storage only REAL TIME CLOCK Typical accuracy is less than one minute per month drift Battery Lithiu
5. m Coin Cell Typical lifetime of 10 years at 25 C A Battery Low system variable is available so that the programmer can choose specific action s to occur when the battery voltage drops below its nominal voltage ENVIRONMENTAL CONDITIONS Operating Temperature Range 0 to 50 C Storage Temperature Range 30 to 70 C Operating and Storage Humidity 80 max relative humidity non condensing from 0 to 50 C Vibration According to IEC 68 2 6 Operational 5 to 150 Hz in X Y Z direction for 1 5 hours 2 g s Shock According to IEC 68 2 27 Operational 30 g 11 msec in 3 directions Altitude Up to 2000 meters 7 CONSTRUCTION Case body is burgundy high impact plastic and nn a stainless steel Installation Category I Pollution Degree 2 8 POWER CONNECTION Removable wire clamp screw terminal block Wire Gage Capacity 24 AWG to 12 AWG Torque 4 45 to 5 34 in lb 0 5 to 0 6 N m 9 MOUNTING Snaps onto standard DIN style top hat T profile mounting rails according to EN50022 35 x 7 5 and 35 x 15 10 CERTIFICATIONS AND COMPLIANCES SAFETY UL Listed File E302106 UL508 CSA 22 2 No 14 M05 LISTED by Und Lab Inc to U S and Canadian safety standards UL Listed File E317425 ANSIJISA 12 12 01 2007 CSA 22 2 No 213 M1987 LISTED by Und Lab Inc to U S and Canadian safety standards IEC 61010 1 EN 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 ELECTROMAGN
6. oft operating systems will not lock the drive unless they need to write data Windows 98 may lock the drive any time it is mounted thereby interfering with logging Refer to Mounting the CompactFlash in the Crimson 2 0 User Manual ORDERING INFORMATION Data Station with multiple protocol converter Comms Ethernet and DSPLE000 expansion slot Data Station with multiple protocol converter data logger web DSPSX000 Data Station Plus server with Virtual HMI up to QVGA 320 x 240 and expansion slot Data Station with multiple protocol converter data logger web server with Virtual HMI up to VGA 640 x 480 size and expansion DSPGT000 slot with increased SDRAM RS 232 Programming Cable CBLPROGO Communications Cables 10 feet USB Cable CBLUSBOO Communications Cables 1 CBLxxxxx DIN Rail Mountable Adapter Products DRxxxxxx Software SFCRM2_ Crimson 2 0 2 Manual and Download Cable SFCRM200 2 Use this part number to purchase the Crimson software on CD with a printed manual USB cable and RS 232 cable 3 Red Lion offers RJ modular jack adapters Refer to the DR literature for complete details 4 Industrial grade two million write cycles
7. red lpn MODEL DSPLE DATA STATION PLUS c US LISTED IND CONT EQ 34AD UL us LISTED FOR USE IN HAZARDOUS LOCATIONS PROGRAMMABLE Class I Division 2 Groups A B C and D CONTROLLERS GENERAL DESCRIPTION The Data Station Plus was designed to act as a nexus for industrial data collection and management With three built in serial ports and a 10 Base T 100 Base TX Ethernet port the unit performs protocol conversion allowing disparate devices to communicate seamlessly with one another The Ethernet port supports up to four protocols simultaneously so even Ethernet to Ethernet conversion may be performed The CompactFlash card allows new configuration files to be loaded into the Data Station Plus The USB port may be used for blazing fast file downloads or to mount the Data Station s CompactFlash card as an external drive to your PC The Data Station s DIN rail mounting saves time and panel space and snaps easily onto standard top hat T profile DIN rail SOFTWARE The Data Station is programmed with Crimson 2 0 software for Windows 2000 or later platforms The software is an easy to use graphical interface which can be purchased as part of a kit that includes a manual and cables or downloaded free of charge from www redlion net DIMENSIONS In inches mm 3 09 78 5 e 4 15 105 4 134 7