1. 33 4 1 O A O 34 4 2 DONE E e re 39 4 2 1 Procedure for using DCON_LabVIEW occccoccnccccccccccncnoconccncnonocnnconnnonanononanoss 35 4 2 2 LabVIEW Example Reading multi channel analog Input value 36 4 2 3 LabVIEW Demo Program Reading multi channel analog input value 38 4 3 DEON Tod SO dass dd 39 4 3 1 Procedure for using the InduSoft bundled driver 39 4 3 2 InduSoft Example Reading an analog input value 39 4 4 NAP OP Gi SOI Ve ersehen 43 4 4 1 Procedure for using the OPC Server ccccccseceeeeeeeceeeeseeeeseeeesaeeeeseeeetaeeeas 43 4 4 2 OPC Server Example Reading an analog input value 43 ADDENGIX A Dimension aa 45 Appendix B Compare USB 87Pn with l 87Kn eere eee 49 Appendix C Solution for 87K I O module on the slot 50 Appendix D Appendix E Description For ini Files cm 55 Frame Ground van 56 USB 87P1 2 4 8 User Manual Version 1 3 FIGURE FIOT Wew orS Plhliasa radio 13 FOZ Wire the 87Prn to power and PO an 14 FIGS OPS GPU MOGUIC rosana 14 Fig 4 USB 87P1 2 4 8 CPU module description ccconcccconncccoccncnncnnnoncnnonacononacnnnoncnonnncnnos 15 Fig 5 Pl g in the lO Mod una a a
2. Parity Option Ww Mone Even Odd u Oc Fig 11 Run Dcon Utility and search 87Pn USB 87P1 2 4 8 User Manual Version 1 3 19 Please click start search button to search File COM Port Search Eun Terminal Help At the first time you can search for USB 87Pn only because the slots of USB 87Pn haven t completed the configuration The X X X X of Status means the configuration of that slot is not completed or corrected Please click stop search to stop the search Start 0 End 255 Address 0 255 Format eStats Description USB arP4 1 115200 Disable N 8 1 Auto Config Enable 5 55 Slot Auto Configuration USE Uni D COM When found USB 87Pn click to stop search IX X X X of Status means the configuration of that slot is not completed or corrected Click USB 87Pn and open the Configure Module screen to setup Arale MAddress Baudrate 58 57P4 115200 Disable Check Module Status For maintenance routine 1 Can check configuration details 2 Can check configuration status Ok or Error Configure Module For module configuration 1 Can online offline configure the 87K l O modules 2 Can save configuration to file 3 Can load configuration from file USB 87P4 CPU Module USB 87P1 2 4 8 User Manual Version 1 3 20 3 1 1 87Pn Auto Config Enable Auto Config ON expressed that the 87Pn s Auto Configuration func
3. NNN i 7000 8000 87K Series i EISEN IA RAIN TEE Supported OS Windows 98 NT 2K XP File Location CD Napdos Driver DCON_Labview 4 2 1 Procedure for using DCON LabVIEW Step 1 Install the DCON LabVIEW by executing B CD Napdos Driver DCON_Labview DCON_Labview exe After installation the related information can be found as below HereBrkrr a Outlook Express gt ES Microsoft Excel S Microsoft PowerPoint a Address C DAQPrO DCON_LabYIEW 7000Demo File Folder 8000Demo File Folder H A My Documents a My Computer Bi dg 3 Floppy A DCON LabVIEW A nin ig Folder B Local Disk C capa i a MEE CallDLLinLab VIEW 45 KB Adobe Acrobat D EE Dagro 8000Demo es iE Be EC DCON DLL lle Fold DCON DLL p 2 423KB Adobe Acrobat D E DCON Lab graph File Folder 17000 dl 152KB Application Exten Eg DCON LabVIEW A 17000 I1b 1 009KB LabVIEW VI Libra E El 23 7000Demo Hels 1 11 2005 2 17080 IIb 671 KB LabVIEW VI Libra 1 8000Demo 4 22 2 18000 IIb 594KB LabVIEW VI Libra AR 187K llb 519KB LabVIEW VI Libra Attributes normal 3 L art dll 40KB Application Exten 3 DCON_Utilty E uart iib 283KB LabVIEW VI Libra Y PCILOO2Ly sa Uninst isu 27KB ISU File oof YY PCI1202Lv amp watchdoa lib 392KB LabVIEW VI Libra El PCI 180 Win2000 XF EHI PIO 821 E PIODA winz000 i as Pantera ar un E CI i 1 object s selected a My Computer A 80
4. Help gt gt Show Help or DCON_DLL paf in step1 for detail Diagg Help 9 dwBaudR ate cPort E M cParky cStop Open Com VI gt Untitled To initial and open com port cPort 1 255 dwBardrate 150 300 600 1200 2400 4800 9600 19200 38400 57600 115200 230400 460800 921600 cData 5 6 7 8 cParity OwNon Parity 19Odd Parity 2 Even Party cStop 021 stop bit 121 5 stop bit 222 stop bit Return Os NoError others Error Code Step7 Draw the data flow of sub vi USB 87P1 2 4 8 User Manual Version 1 3 3 4 2 3 LabVIEW Demo Program Reading multi channel analog input value Step 1 Select the appropriate demo program ex AnaloglnAll vi by the name according with module s function ex l 8017 Al Step2 Set the parameters gt AnaloalnAll yvi PU y h cun em ru e a 7 gw bo bo bow boo bom boo bom Fond nmm amd e ja lt um i You could also refer the Help gt gt Show Context Help for getting the simple description of those parameters uam A i T Ret gt AnalogInAll vi Diagram Y 020 v Fos n ai gt A sz ecetve rom7000 e ET 18 or Application For AnealogInAN 8K vi Read the al channels of analog input values R5 232 poet number 1 255 module address 0x00 MFF module id 0x8013 17 18 checksum i USB 87P1 2 4 8 User Manual Version 1 3 38 Step3 Run the Demo 4 3
5. Search removable media floppy CD ROM C Include this location in the search Don t search will choose the driver to install Choose this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware TUM mem a Step9 please click Continue Anyway to continue the Installation Found New Hardware Wizard Please wait while the wizard installs the software Hardware Installation The software you are installing for this hardware y USB 87Pn TEST has not passed Windows Logo testing to verify its compatibility with Windows lt P Tell me why this testing is important Continuing your installation of this software may impair es or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing qu STOP Installation USB 87P1 2 4 8 User Manual Version 1 3 10 Step10 In this screen you already finished the installation please click Finish to exit the program Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for E USB 87Pn I Click Finish to close the wizard lt Back Finish L ancel Step10 Please confirm the installation of USB 87Pn and to
6. 8fPA Hot Swap and Auto Configuration 1 0 Write To 87P4 Addr Hex Slot Configuration Status set As Scanned O fezorar f o UHOK Copp Configure Immer 03 OH OK Copy Configure 87018R 2 87024 yi 04 p HOK Copp Configure D 8 fess 05 HOOK Copy Configure r Configuration Modified Ea Fig 14 Complete the 87Pn configuration then serch again As above all the settings for each modules has configured correctly by DCON Utility and then search the module again you can see each plugged I O module name will be listed under the screen File OM Port Search Run Terminal Help x Address 0 255 Checksum Forma Status A m Description LI ante 115200 Disable Auto Conti 4 Slot Auto Configuration USB Unt DCON Z o019R 115200 Disable BrP4 Slor C al Universal m m w Thermocouple DCOM 87018R 115200 Disable arP4 Slot 1 BAI m mV Thermocouple OCON 57024 115200 Disable a ofP4 Slot 2 4 40 m VD CON oF 005 115200 Disable ofP4 Slot 3 oD 8DO DCON Fig 15 After configuring you can find out the entire module The Auto Config Enable 0 0 0 0 of Status means The I O configuration of each slot is correct If module is damaged you don t need to shutdown the power just remove the damaged one and install the same model number of new module 87Pn will write the previous settings to the module automatically
7. A ICP165 Y Computer See Disk drives Y Display adapters DYD CD ROM drives 3 Floppy disk controllers 3 IDE ATA ATAPI controllers 3 Keyboards Try E 3 Mice and other pointing devices Monitors HE Network adapters Ports COM amp LPT A Communications Port COM1 CA CU USB Serial Controller MB Processo 8 Sound video and game controllers System devices Universal Serial Bus controllers USB 87P1 2 4 8 User Manual Version 1 3 9 Step7 When you connect the USB 87Pn to your PC It will show following diagram please Select Install from a list or specific location Advanced then click Next gt Found New Hardware Wizard Welcome to the Found New Hardware Wizard This wizard helps pou install software for USB 87Pn If your hardware came with an installation CD SEP or floppy disk insert it now What do you want the wizard to do Install the software automatically Recommended Install from a list or specific location Advanced Click Next to continue Steps Without any change Click Next gt to next step Found New Hardware Wizard Please choose your search and installation options a S Search for the best driver in these locations Use the check boxes below to limit or expand the default search which includes local paths and removable media The best driver found will be installed
8. MEE Copy Configure Dee Save Configuration Load Configuration Load Configuration And Write To 87P4 7 Help Exit Fig 19 Load amp Write the configuration file USB 87P1 2 4 8 User Manual Version 1 3 scanned IO on Slot IE BEE U EEE 27 Look in e for users e er EJ 87p4Demo My Recent Documents Select the file name and click Open to open the file Desktop My Computer File name 87p4D emo v My Network Files of type ini v Places Open as read only 87P4 Hot Swap and Auto Configuration scanned 1 0 on Slot 170 Write To 87P4 Addr Hex Slot Configuration Status _SetAs Scanned Write To 87P4 pmo ff o2 quHoK Copp Configure Ber f o3 UHIOK Copy Configure a dj J J ep Configure E Fe Bg M wj Configure S W Jj d40 Mops Configure WS 3g Cop Configure 3 4 Operating in off line mode When you want to use Docn Utility to configure the modules but your computer did not connect any USB 87Pn You can configure the settings and save the configuration file in off line mode 87P4 Hot Swap and Auto Configuration Scanned I O on Slot 170 Write To 87P4 Addr Hex Slot Configuration Status 2200 Write To 87P4 SYSTEM 0 8701 IR 02 Empty Copy Configure UNIT 87P4 peo Empy E EZ COMMENTS 2 NE Empty Copy Configure Date Time 2007 9 11 FF 03 5
9. 00 00 Modbus Response Delay Time Setting JU H Delay Time p lt 0 30 ms 3 W CH pnnonn CS D0 00 00 00 Configure CIC Offset CJC Temperature 00 00 Enable CIC Select All Clear All ED Set All as CH D Module CIC Offset 0000 C Disable CIC r Adjustable CJC Increment E olibratia Exit us 01 Setting Configure only for auto configuration Note When you change the settings please click Setting to confirm USB 87P1 2 4 8 User Manual Version 1 3 24 67P4 Hot Swap and Auto Configuration i pocanned I O on slot 140 Write To GPa Addr s Slot Configuration Status et As Scanned i Write To 87P4 J 87019R IA 00H OK Copy Configure 37019 1 18701 aH Fi Write Description For Configuration File 2 187024 Write Description For Configuration File 187055 al Input the description or notes for this configuration file Cancel Save in 73 for users v D My Recent Documents E Input the file name and click Save to save the file Desktop My Documents E My Computer gt a File name 87P4D emo M My Network Save as type ini y Places 3 2 2 Load the Configure file Yon can use this function when you want to duplicate the same settings to other USB 87Pn or load the prior configuration file in the same US
10. 53 el Scanned on Slot pT po A save Configuration Load Configuration Load Configuration And Write To 87P4 Help Exit Fig 25 Write the settings to USB 87Pn USB 87P1 2 4 8 User Manual Version 1 3 32 Chapter 4 Software Development Kits SDK The ICP DAS provides a series of free software development kits enables the customer to be fast and simply completes the system setup Related software tools are in the CD please refer to following diagram Driver NapOPCSvr USB 87P1 2 4 8 User Manual Version 1 3 33 4 1 PACSDK PACSDK provide program developers to read the program interface which used on control I O modules the position of CD place provides a few basic and simple examples user can understand how to read the control l O module through the DLL in following examples Supported Windows OS for PC Operation System Windows XP Windows 7 Windows All document for APCSDK is located at CD or FTP latest version CD 1 Napdos Driver PACSDK or ftp ftp icpdas com pub cd 8000cd napdos driver pacsdk PACSDK can be used on C C C Delphi Borland C and etc Development environment About more description about it please refer its user manual ftp ftp icpdas com pub cd a000cd napdos driver pacsdk document USB 87P1 2 4 8 User Manual Version 1 3 34 4 2 DCON LabVIEW MS DCON LabVIEW Bundled driver for LabVIEW Supported module y Ea gt 7012 ey 100 Bo Bou
11. Remove the damaged module Plug in a new one with the same model number USB 87P1 2 4 8 User Manual Version 1 3 22 3 1 2 87Pn Auto Config Disable Working Distinction In 87Pn Auto Config Disable mode allow the I 87K I O modules to external communications even you haven t completed the configuration Therefore when you perform searching by DCON Utility you could find 87Pn CPU module as well as 87K I O modules on the expansion slot But you can t click USB 87P4 to setup the modules in this mode File COM Port Search Eun Terminal Help gt rr eg Start 0 End 255 Address 0 255 Module Address Baudrate Checksum Format Status kk Description 115200 b M 8 1 1 1 Disable Auto Coa Disable 0 0 0 0 4 Slot Auto Configuration USE Unt D COM 2 115200 Disable M 8 1 BrF4 Slot L Bl Universal m mv Themocouple DLOM 3 3 115200 Disable M 8 1 Br P4 Slat 1 al m mi V Thermacouple D CON 4 4 115200 Disable M 8 1 azP4 Slot 2 FAD mA V D CON 515 115200 Disable M 8 1 ofP4 Slot 3 oD S DO DCON Fig 16 When 87Pn Auto Config Disable all the module can external communication In 87Pn Auto Config Disable mode doesn t support Auto Configuration When the module damaged and replaces another module with the same model number directly lt may be doesnt work well because of their settings e g Type code is different The user must use DCON Utility to re configure
12. 2 4 8 User Manual Version 1 3 46 A 3 USB 87P4 Unit mm E LLLLL a q Front View Right Side View USB 87P1 2 4 8 User Manual Version 1 3 47 A 4 USB 87P8 Unit mm arar A cM EAE CARA EAE ELAR EN Auxiliary View 138 E Top View Right Side View Front View 48 USB 87P1 2 4 8 User Manual Version 1 3 Appendix B Compare USB 87Pn with I 87Kn Note 1 87K I O module has divides into the high profile new version and the low profile old version two kinds only I 87K high profile series I O modules can support Hot Swap and Auto Configuration function correctly USB 87Pn 4 I 87Kn I O unit comparison USB 87Pn with Supported agi tote Auto Config I 87Kn g Disable I 87K Low Profile module OS Il 87K High Profile module I 87K module Hot Swap Auto Communication parameter Setup Auto Configuration A c cm E a End Oo a I 81 08 102 14 Fig 26 1 87K high low profile series I O modules Please refer to web page http www icpdas com products PAC I 8000 8000 IO modules htm USB 87P1 2 4 8 User Manual Version 1 3 49 Appendix C Solution for 87K I O module on the slot When insert the module on the expansion slot of 87Pn the same time 87Pn CPU will detect the module name and respond the status of interacting between 87Pn and module As following diagram the search result only fi
13. Terminal Help gt MT CE EJ Start 0 End 255 Address 0 255 Module Address Baudrate Checksum Format Status Description EJ Hot8wap Serail Model lUSB B7P4 EN 5200 s l amp p Status COM Port Sg Address 00 dec Ofhex Baud Rate 9600 Part Mana Data Bit g Stop Bit 1 Fig 22 Off line operation USB 87P1 2 4 8 User Manual Version 1 3 29 Click Configure Module to enter setup screen Check Module Status Fl 87P4 OFF Line Configuration For maintenance routine 1 Can check configuration details 2 Can check configuration status Ok or Error Configure Module 1 Can online offline configure the 87K O modules 2 Can save configuration to file 3 Can load configuration from file USB 87P4 CPU Module 8 P4 Hot Swap and Auto Configuration scanned I O on Slot YO Write To 87P4 Addr E Slot Configuration Status z HI j DIT Empty EH Configure 1 Empty Copy Configure 2 04 Empty Copy Configure 3 Empty Copy Configure AZ MC ee eee ee ee ee cave Configuration Load Configuration Load Configuration And Write To 87P4 m Step2 Select and configure the l O modules then click Save configuration to save the settings as the file or else next time when you open the configure module screen in off line mode the previous settings will be d
14. With DCON Protocol rex E ES Modbus embedded controller a 7 ISaGRAF embedded controller l Supported OS Sane Windows 98 NT 2K XP CE File Location CD Napdos NapOPCSvr OPC OLE for Process Control is the first standard resulting from the collaboration of a number of leading worldwide automation suppliers working in cooperation with Microsoft Originally based on Microsoft s OLE COM component object model and DCOM distributed component object model technologies the specification defined a standard set of objects interfaces and methods for use in process control and manufacturing automation applications to facilitate interoperability The COM DCOM technologies provided the framework for software products to be developed There are now hundreds of OPC Data 4 4 1 Procedure for using the OPC Server Step 1 Read the basic and important documents Readme txt contains the basic and important information including B Files on the shipped CD Reversion txt contains the reversion information including B Bugs fixed B New modules supported Step 2 Install the OPC Server by executing B CD Napdos NapOPCSvr NapOPCServer exe Note If there is an older version of Nap OPC Server installed on the PC It must be uninstalled before installing the new version Step 3 Read the manuals describing how to start B The NapOPCSvr pdf is the user s manual describing how to use the OPC Server 4 4 2 OPC Server Example Reading an analog input va
15. and demos are provided such as DLL Activex LabVIEW driver InduSoft driver Linux driver OPC Server etc The I 87K series l O modules plugged in the USB 87Pn can be easily integrated into variant software system Features Hot Swap The USB 87Pn doesn t need to shut down its power to replace or plug l 87K I O modules Therefore the whole system can keep operating without any interruption Auto Configuration Configurations of I 87K I O modules can be pre configured and stored in the nonvolatile memory of the USB 87Pn When the USB 87Pn is power on or an l 87K I O module is plug in the USB 87Pn automatically check and restore these configurations to each I 87K I O modules on it Easy Duplicate System Using the DCON Utility you can easily make a backup of the I 87K module configurations and write to another USB 87Pn This design can easily and quickly duplicate many USB 87Pn Easy Maintenance and Diagnostic The basic configurations Auto Config ON OFF are set by the DIP switch The operator can use only one screwdriver to set the USB 87Pn And there are several LED status indicators to show whether 87K modules are configured and work properly If one I 87K module is damage the user just need to get the same model number and USB 87P1 2 4 8 User Manual Version 1 3 4 good 87K module to replace the damaged one And then check the LED indicators to know whether the replacement is performed correctly The switc
16. icpdas com pub cd 8000cd napdos 87pn io unit usb 87pn Note The old version of USB 87Pn with old USB chip needs to install old USB driver it is located at CD Napdos 87pn_io_unit USB 87Pn old ftp ftp icpdas com pub cd 8000cd napdos 87pn io unit usb 87pn old Step1 Double click USB 87Pn Driverlnstaller exe to enter the installation screen which will quide you through the rest of the setup process Please En USB 87Pn Driver Setup is preparing the InstallShield Wizard 1 wait AAA AAA Step2 Click Next gt to next step InstallShield Wizard Welcome to the InstallShield W izard for USB 87Pn The InstallShield Wizard will install USB 87Pn on pour computer To continue click Next Bact MI Cancel AEN Step3 Reading the license If you accepted all of the license items please click Yes to next step InstallShield Wizard License Agreement Please read the following license agreement carefully Press the PAGE DOWN key to see the rest of the agreement End User License Agreement ELLA Do not install or use the software until you have read and accepted all of the license terms Permission to use the software is conditional upon your agreeing to the license terms Installation or use of the software by vou will be deemed to be acceptance of the license terms amp cceptance will bind you to the license terms in a legally enforceable contract with Prolific Technology Inc SOFTW
17. oi 15 F9 6 s Description Of LED INGICALON si Aa 16 Fig 7 21 820 19R Internal VO STOCU susana 16 Fig 8 1 87019R Pin assignments amp Wire Connection cooccccccncccnccnnccncnnnncncnnnncncnnnncnnonnncnns 17 FOS 2 VO module terminal Conheellon u een 17 Fig 10 Installing USB 87Pn extension unit 0222400220000000000nnnnn nennen nennen 18 Figs I RUN Deon Jblity and sSearch BAP Messiaen da 19 Fig 12 Auto Config Enable setup the 87Pn 22uu022220enennnenennnenennnonennnnnenne nenne nennen 21 Fig 13 Follow 3 steps write the settings to 87PN ooccoccncconccocnoconcconncnnnonancnnnnonononanonanonnnos 21 Fig 14 Complete the 87Pn configuration then serch agalin occcccoccccoccnnoccnnnonacnnnnannnonannnes 22 Fig 15 After configuring you can find out the entire module oocccoccccnccccnnccnoncnnnncnnnnconnns 22 Fig 16 When 87Pn Auto Config Disable all the module can external communication 23 FIGs Ie SAVE ING COMU e e ol 24 FIG 18 Load the congiurati Terre 25 Fig 19 Load Write the configuration file ccooocccconncccnnoconnnconnnconnnnannonannonannnnannnnos 27 Fig 20 Configure and save file in off line mode ocoooncccconccccncnncnncnnnnncnnonncncnnncnnnnnrnnonanonos 28 Fig 21 Load amp write Configuration file through other PC ococccoccccnnccnncnconcnncnnnnacnnnnncnnnnnnnnos 29 A ee o o eO ide 29 Fig 23 Off line operation C
18. to open the file a File name oft Line setup Y Open j P My Network Files of type ini Cancel PI mise Open as read only USB 87P1 2 4 8 User Manual Version 1 3 31 Click Configure button to check whether the settings is correct A Configuration for 87P4 Module Version A202 PWR S RDY CO Auto Config USB 87P4 CPU Module 87 P4 Hot Swap and Auto Configuration 120 White To 87P4 Add Hex Slot Configuration Status O jemar o2 OTH ModulescamedinEmptysiot Gu feum 03 DH Module sconnedinEmpy slot Cop Configure o wu v 04 J OIHJModulescamedinEmpiysiot Cop Confisue 3 faves v os J OIHJModule scamedin Emptyslot Copy Configure q qp e Sent MC es EEE oo A EE EEE Scanned l O on Slot Ce as AA Save Configuration Load Configuration And Write To 87P4 Help Exit SYSTEM LINIT 87 P4 COMMENTS Date Time 2008 3 10 TF 03 33 32 Description Write Description For Configuration File up Configuration for 87P4 Module Version A202 PWR S RDY Auto Config USB 87P4 CPU Module 8 7P4 Hot Swap and Auto Configuration 3 140 Write To 87P4 Addr Hex Slot Configuration Status Set As O feroran x ow BMok Cony leo n3 UHoOK Copy Configure 2 87024 x ta HOOK Copy Configure Bisse o HOOK Copy Configure dE B 3 7 dE A dE BH 1 zd B
19. uoo 0 REE ES m Fig 9 I O module terminal connection USB 87P1 2 4 8 User Manual Version 1 3 JP1 JP8 JP1 5 JP8 17 2 2 7 Installing USB 87Pn extension unit Method 1 using the screw to fixed Method 2 using the DIN rail clips to fixed Fig 10 Installing USB 87Pn extension unit USB 87P1 2 4 8 User Manual Version 1 3 18 Chapter 3 Software Configuration In this chapter we will use DCON Utility to complete software configuration of the USB 87Pn please confirm the hardware equipment has connected and 87Pn CPU module has setup completes Please refer to Chapter 2 3 1 Setup USB 87Pn with DCON Utility 3 2 Save amp Load 87Pn configure file 3 3 Load amp Write configure file 3 4 Operating in off line mode 3 1 Setup USB 87Pn with DCON Utility At first please run DCON Utility then click COM Port to select COM Port and baud rate You can check your PC s Device Manager to know which COM is connecting Click OK to confirm and escape the screen DCON WILITY ER452 Searching for I 700078000 Modules S COM Part Jeuch Run Terminal Help Time Out Setting Sn Me You can check your PC s Device Manager to know which COM is connecting E v 115200 Ber 38400 13200 v 3B 4800 2400 1200 Select All Clear Protocol Option w DCON Modbus ATU Modbus ASCII Checksum Option Disable Enable
20. 00 Demo Demo programs for 8000 I O modules USB 87P1 2 4 8 User Manual Version 1 3 35 3000 1lb LabVIEW library contains all sub vi for 8000 I O modules CallDLLinLabVIEW pdf Explains how to call a sub vi of in LabVIEW DCON DLL pdf Descriptions of all sub function in DCON DLL Step 2 Create a new LabVIEW program Refer the DCON DLL pdf about detail description of the sub vi and where to select the sub vi in various library of DCON LabVIEW Step3 Select the sub vi form Functions Palette gt gt Select a VI TES xi Fille Edit Operate Project Windows Help actions ft Application Font v S5 5 gt ge ral 4 2 2 LabVIEW Example Reading multi channel analog Input value Step4 Select the target lib file LabVIEW library file Choose the VI to open xl Look in Cy DCON_LabVIEW e E32 _ 7000Demo 8000Demo File name uart IIb Files of type VIs amp Controls vi cH vit ctt Cancel USB 87P1 2 4 8 User Manual Version 1 3 36 Step5 Select the desired sub vi File Dialog uz DakaSizeQutCom vi ur err wi uz Seb Com Status VI uz Get Wart Version vi uz GetLineStatus vi yz Open Corn VI i Receive Binary wi iz Receive Cmd vi iz Receive Cmd Wwikhichar vi uz Send Binar wi Choose the VI to open open Cam vt Cancel vIs amp Controls Step6 Put the icon of selected sub vi on Block Diagram refer the
21. 6 30 Empty Configure Desci ption Write Description For Configuration File MODULE_CONFIG To cmm 87Pn Offline To Generate Configured file Fig 20 Configure and save file in off line mode USB 87P1 2 4 8 User Manual Version 1 3 28 And then you can copy the file to another computer which connected with 87Pn Run the DCON Utility and enter configure module screen You can click Load Configuration And Write To 87P4 to write the settings to 8 Pn this usage is convenient for remote support or system backup Note The configure file will be save to CNCPDASWDCON Utility for_users e a cats tetonas wae roere VRR AA En o s pern ok Copy _Configure gu s opy onfigure On the other side DCON Utility loads the gene aoe uale ES Gee 3 ez055 05 fo Copy Configure configured file and writes to 87Pn directly SYSTEM UNIT 87P4 COMMENTS Date Time 2007 9 11 FF 03 56 30 Save Configuration Load Configuration Load Configuration And Write To 87P4 Description Write Description For Configuration File Help Exit Fig 21 Load write Configuration file through other PC Follow the steps you can setup amp save the configuration file without connected 87pn and then write this file to any 87Pn Step1 Click off line button and select the Module ID Address Baudrate and Checksum File COM Port Search Eun
22. 8700 8000 compatibles NT 94 20 DDS nD See mt DEVN Hilscher Synergetic board DeviceNet Slave NT 7200079x DISOM SCHENCK Disomat C NT 2000 9x v1 04 DL50 ALLEN BRADLEY Dataliner DL50 Display NT 2000 9x DSC DSC Reader DSC NT 2000 9x CE x86 Sh3 Sh4 4AM Selected drivers DLL Step 4 Setup DCON driver Baud Rata Workspace xj Dala Bilz ly Project MYTEST APP ES a Drivers Stop Bitz 3 Step 5 Insert tags to connect to I O modules The address format is Address Module ID Slot Channel USB 87P1 2 4 8 User Manual Version 1 3 o 1 X Help Sting E 40 Is f Workspace SI e ee MY TEST APP SDCONOD DRY 2 3 Drivers Be ree c xm gt m Map 01 8017 0 0 AI 01 8017 0 1 AI 2 01 8017 0 2 AI 3 01 8017 0 3 Al 4 01 8017 0 4 Al 01 8017 0 5 01 8017 0 6 Step6 Arrange all the components on the form E Main ser TILA ARI USB 87P1 2 4 8 User Manual Version 1 3 41 Step7 Double click the text box to assign a tag to it Object Properties qs Mr Value A Enable E Marmunm vade Password JE Coni AUS JEU F ISauie E Step8 Run the project USB 87P1 2 4 8 User Manual Version 1 3 42 5 gt NAP OPC Server POET NAP OPC Server E ny t OPC Server ran mf iris 97 Supported Module pepe i 7000 8000 87K Series Si ae
23. ARE LICENSE AND LIMITED WARRANTY This is an agreement between you the end user and Prolific Technology Inc Prolific s gt Do you accept all the terms of the preceding License Agreement If you choose No the setup will close To install USB 87Pn you must accept this agreement USB 87P1 2 4 8 User Manual Version 1 3 8 Step4 In the next screen please click Continue Anyway to continue the Installation Software Installation A The software you are installing has not passed Windows Logo testing to verify its compatibility with Windows lt P Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the software vendor for software that has passed Windows Logo testing Continue Anyway STOP Installation en Step5 In this screen you already finished the installation please click Finish to exit the program InstallShield Wizard InstallShield Wizard Complete InstallShield already successfully to installed USB 87Pn Converter driver Please press Finish button to close and out of InstallShield If you have been plugged cable on PC before run this setup please unplug and then plug cable again for system detect this device C Device Manager File Action View Help om amp
24. B 87Pn At first please click Load Configuration 8 7P4 Hot Swap and Auto Configuration 1 0 Write To 87P4 ie Slot Configuration Status et As Scanned Write To 87P4 2 me GA Modde seamed n Empy st m TE a rscanned l O on Slot Save Configurationk Load Configuration Load Configuration And Write To 87P4 Help En Fig 18 Load the configuration file d USB 87P1 2 4 8 User Manual Version 1 3 25 Look in C for users er E3 15 Ben My Recent gt Documents C gt Select the file name and click Open to Ly open the file My Documents My Computer a File name 87p4D emo d My Network Files of type ini Places Desktop Open as read only Fl Write Description For Configuration File SYSTEM UNIT 87P4 o O COMMENTS CO Description for Date Time 2008 3 11 F 04 30 29 Desnos configuration Write Description For Configuration File file Slot Comments ID S70 9R Firmware A20lh 8 P4 Hot Swap and Auto Configuration 140 Write To 87P4 Add Hex Slot Configuration Status O ezU9R 02 I s7018R 2 won 04 MiHlModulescannedinEmptyslot Copy Configure 3 eus o OTH ModulescannedinEmplyslot Copy Configure Ro E 2 ots nA CC MC E mul ZI pC save Configuration SYSTEM UNMT o7 P4 COMMENTS Date Time 2000 3410 F
25. DCON InduSoft DCON InduSoft Bundled driver for InduSoft Supported module 7000 8000 87K Series With DCON Protocol Supported OS Windows 98 NT 2K XP CE File Location CD Napdos Driver DCON_InduSoft 4 3 1 Procedure for using the InduSoft bundled driver Step 1 Read the basic and important documents Readme txt contains the basic and important information including B Files on the shipped CD Reversion txt contains the reversion information including B Bugs fixed B New modules supported Step 2 Install the InduSoft bundled driver by executing B CD Napdos Driver DCON_InduSoft Setup setup exe Step 3 Read the manuals describing how to start B The DCON pdf user s manual describes how to use the InduSoft bundled driver Step 4 Run the demo programs ICPDriverTest zip to test l O modules and learn the functions 4 3 2 InduSoft Example Reading an analog input value The following is an example of reading analog values from an 1 87018 inserted in slot O of an 8410 8810 USB 87P1 2 4 8 User Manual Version 1 3 39 Step 1 Run the DCON Utility to configure the I O modules Step 2 Run InduSoft and create a new project Step 3 Include the DCON driver Wl O rksp ace p Project APPL APP nn A dd Eemove drivers N gt Available drivers CUTL CUTLER HAMMER D50 D300 NT 2000 CE x86 Sh D4100 YOKOGAWwA 04100 NT 2000 3x 1 05 DAY Br Down O E Database lp Gra em N ICP DAS Senes 7000
26. E Urnit D CON 2 115200 Disable N 8 1 BrF4 Slot D Al Universal m mV V Thermacouple D CON 3 3 115200 Disable N 8 1 BrP4 Slot 1 BA m nm Thermocouple DCON 4 4 115200 Disable N S 1 BrPF4 Slot 2 440 mar DCON F 5 115200 Disable HS BrP4 Slot 3 201 amp DO DCON USB 87P1 2 4 8 User Manual Version 1 3 5 87P4 Hot Swap and Auto Configuration scanned I O on Slot 1 0 Write To 87P4 Addr Hex Slot Configuration Status _Set As Scanned Write La 87P4 87019 Oe fo HOK Copy Contigure egsm f 03 DOHJOK Copy Configue 2 feroza 04 00H OK Copy Configure 3 fezoss 05 00H OK Copy Configure NH 4M 1 col E W Jg cop Configure EE AA J copy Conie m FA Jy L fc Configure B OPC Servers OPC is an industrial standard interface based on OLE technology With the OPC server I O modules can be easily integrated to any software that has OPC client capability B EZ Data Logger EZ Data Logger High Low Alarm Datatrend Database and Report Layout EZ Data Logger is small data logger software It can be applied to small Remote O system With its user friendly interface users can quickly and easily build a data logger software without any programming skill B Support Variant Software Develop Toolkits The free charge for DLL ActiveX LabVIEW driver InduSoft driver DasyLab driver Linux driver USB 87P1 2 4 8 User Manual Ver
27. F 03 33 32 Diescrption Write Description For Configuration File USB 87P4 CPU Module USB 87P1 2 4 8 User Manual Version 1 3 Click Write To 87P4 to write the configuration to 87Pn CPU module Configuration for 87P4 Module Version A702 8 P4 Hot Swap and Auto Configuration 140 Write To 87P4 Addr Hex Slot Configuration Status O je719R 02 AA Copy onfigure fezorer o3 WHOK Copy Cenfigue 2 leroza 0 quHjK Copp Contigwe 8 jess 05 quHOK Cep Contigwe HE BH 0 0 Dom IE BH 0 0 090 com zB BH 0 0 5 Dom B S Dom save Configuration Load Configuration Load Configuration And Write To 87P4 USB 87P4 CPU Module 3 3 Load 8 Write the configure file ES Scanned I O on Slot Help Exit lf you sure the contents of configure files is what you need you can load the configuration and write to 87Pn at the same time As following diagrams this function is useful for a lot of copy to other 87Pn Click Load Configuration And Write To 87P4 8 P4 Hot Swap and Auto Configuration 1 0 Write To 87P4 Addr Hex Slot Configuration Status SetAs Scanned Write To 87P4 O Empty gt 02 DH Module scanned in Empty slot Copy Configure I Empty os Copy Configure 2 Empey I 04 Copy Configure 3 Empy z 05 Copy Configure E Copy Configure Copy f Configure
28. The operation steps is very easy you check or modify the settings of each I O module by click Configure button then click Save Configuration button and input the description or notes for this configuration file Finally input the file name of this project to complete Please refer to the description as following diagram 87P4 Hot Swap and Auto Configuration scanned I O on slot 140 Write To 87P4 Addr Hex Slot Configuration Status set As Scanned Write To 87P4 87019R J 187019 Ue 00H OR 87018R 03 00H OK E Configure 87018R 2 187024 04 OOH OK Copy Configure 87024 O WS py Configure A tow Configure W g op tene A eo tone Load Confiquration Load Configuration And Write To 87PA Help Exit Fig 17 Save the configuration file A Configuration for 87019E Module Yersion 4201 Configuration Setting Channel Enable Disable Setting pou J CH CJC Temp Offset Jj 200 00 H 00 00 00 0 helen O E 7 r E OF TC K tupe 00 00 r 00 00 Baud rate Checksum 5e Iv CH 2 OF T C K type 00 00 4 f 00 00 H Data f t zs Complement Forma ata format Aa v CH DF T C K type oo 0000 H DF TC K type oo f 00 00 DF T C K type oo f 00 00 SS v CH DF T C K H type 00 00 3
29. USB 87P1 2 4 8 User Manual Version 1 3 May 2015 Original Writer Martin Hsu Last Writer Hans Chen I O Unit DC 10 30V Power Module t A uss s7P4 f ROLETE ICP DAS Co LTD www icpdas com Table of Contents Chapler T INVOQUCHON auna dado 4 1 1 PECCAN S 22 22 02 u ee een Mt 7 Chapter 2 Hardware Contigua aueh 8 2 1 Iste A deren eE a ee ee Mic UE ICE 8 2 2 Vew OF hes SBOE sesionar 13 2 2 1 FSD al ATOM ernennen ee een 13 2 2 2 Wire the 87Pn to power and PC esses nenne 14 22 3 Uob orPns CPU Modulo ld 14 2 2 4 USB 87Pn series CPU Module Description coocccccocncccccnconcncconcnonanononanoss 15 2 25 PIUS Ihe O AA AA en 15 2 2 6 Winng ihe E O dqmodulgss saco iu en een ea 16 2 2 7 Installing USB 87Pn extension unit ooccccoccnccccnccccnnonocnncnnnnnnncnonnnnnnnnnnnnnononnnos 18 Chapters Software Conflig rallOn imitan 19 3 1 Setup USB 87Pn with DCON Utility ooocccocncocnicocnconncccnocococonnconncnnnnss 19 3 1 1 S7 PH Auto CONTIG EnDable o ossi dece etta aede Dena il 21 3 1 2 87Pn Auto Config Disable THE 23 3 2 Save amp Load 87Pn Configure file occccoocccoccnnnoccnncccnnnncnnnncnncncnonons 23 3 2 1 Save the Gonligure lerne ee 24 3 2 2 Load the Configure le seen 25 3 3 Load amp Write the configure file eese 27 3 4 Operating Nonne Modernes 28 Chapter 4 Software Development Kits SDK
30. able 2 The Error Code in Auto Config Disable mode Error Slot LED RS If it still fails after restart the 87Pn many times Bright Internal INIT The INIT Pin is failed to connect with the j Error pin failed GND and module failed to initialize AEA sena ine 7 0 Imoelule ISl yo tacon to check The maximum address of Briaht Module 87P1 is 254 FEh Error address over The module address is over 255 FFh 87P2 is 253 FDh 255 FFh 87P4 is 251 FBh 87P8 is 247 F7h You can see the LED signals on 87Pn CPU module to know whether the 87Pn is operating properly Please refer to appendix Auto Config LED S RDY LED Auto Config Enable Always ON Always OFF Always ON Always ON Flash Auto Config Disable No Error Always ON Always OFF Always OFF USB 87P1 2 4 8 User Manual Version 1 3 54 Appendix D Description For ini Files While you save the configuration file the DCON Utility will save as ini file The default path of file as below C ICPDAS DCON_ Utility for_users The INI file explains as follows SYSTEM UNIT 87P4 Section 1 Unit Name COMMENTS Date Time 2008 3 10 4r 03 33 32 Section 2 Created date time and Description description for configuration file Write Description For Configuration File Slot0 Comments ID 87019R Firmware A201h MODULE_CONFIG Section 3 Description for each Net Address gt 2 slot module s configuration Baudrate gt 115200 Format gt 2
31. ate the 87K I O module with a new firmware version Bright Error USB 87P1 2 4 8 User Manual Version 1 3 51 Error Configuration 2 Click the Write To 87Pn button to write the settings to failed The configured commands are wrong for 87Pn CPU again DCON Protocol 1 Please insert a correct module as previous configured one 2 Or configure with DCON Utility as Empty and click the Write To 87Pn button to write the configuration to 87Pn CPU Bright Can not find The configured module at this slot has been Error module removed It is empty now Configure failure The insert amp configure module name are different insert The module inserted in this slot is not the the correct one or run the Dcon Utility to modify the same as previous configured settings accord with the module name Configure failure 1 Please restart the power to initialize to I O module 2 If it still failed to initialize send it back to factory to Bright Incorrect Error module name Bright Internal INIT 7 5 INIT Pin is failed to connect with the Check Error pin failed NE GND and module failed to initialize Note USB 87Pn only supports high profile 87K I O modules The maximum address of Module 87P1 is 254 FEh address over The module address is over 255 FFh 87P2 is 253 FDh 255 FFh 87P4 is 251 FBh 87P8 is 247 F7h This error might be caused by following reasons 1 Command length error 2 Command ch
32. ecksum error 3 Communication error during the process of writing commands to 87Pn The command count saved to 87Pn is not the same as DCON Utility Please configure this 87K I O module with DCON Utility and click the Write To 87Pn button to write the configuration to 87Pn CPU again Bright Error USB 87P1 2 4 8 User Manual Version 1 3 52 Bright Error Bright Error Bright Error Please restart the power to initialize to I O module or configure this 87K I O module with DCON Utility and click the Write To 87Pn If I O module often becomes OxBh error it may something caused communication failed between 87Pn and I O module User can send AARCxx command to set XX second to reset I O module when OxBH error appears XX range is O OxFF can be set 0 256 second Module This error might be caused by following response reasons Module response failed above 5 failed times Module is not 87K high profile I O modules Note 87Pn only supports 87K high profile I O modules Please replace it as 87K I O module Module name The module inserted in this slot is not the invalid same as previous configured Reconfigure it with DCON Utility Module Init command invalid This error might be caused by command not complete on I O module 1 Click Set As Scanned button and configure module again 2 Click Write To 87Pn button to write settings to 87Pn USB 87P1 2 4 8 User Manual Version 1 3 53 T
33. eleted MD and Auto Configuration scanned I O on Slot Slot Configuration Status Empty N EEN Configure i Configure Configure Po po po Po PT AL EE HN a load Configuration And Write To 6 P4 Help Exit Fig 23 Off line aperin Configure amp Save file USB 87P1 2 4 8 User Manual Version 1 3 30 Save s E x Save in for_users de ex Er My Recent Documents Beste Input file name AD and click Save to save the file My Documents My Computer i File name off Line setup v Save p My Network Save as type ini Cancel Places Step3 Run DCON Ultility in another computer which has connected with 87Pn load the settings by Load configuration button 8 P4 Hot Swap and Auto Configuration scanned I O on Slot 140 Write To 87P4 Addr Hex Slot Configuration Status Set s Scanned Write To 87P4 Empy IH 02 IF IM Madulescannedinempiysiot copy eomigue WM s70i9R en e f 03 a copr oaan Empty 04 MH Module scanned in Empty slot Copy Configure 87024 Empty 05 01H Module scanned in Empty slot Copy Configure 87055 y u n MM Copy A Configure I y gd py fi Configure E E gd fow Configure oe 3 cop lA Configure 1 Le EE cC save Configuration amp My Recent Documents 3 Select file name Desktop and click Open
34. h and LED design makes it easy for maintenance There is no PC and Notebook needed Communication B USB interface The USB 87Pn use USB communication interface It requires no converter plug and play at run time very simple and convenient to connect with your PC B DCON protocol I 87K series I O modules plugged in a USB 87Pn provide a simple command response protocol Called DCON protocol for communication All command response are in easy used ASCII format Rugged Industrial Environment B Dual watchdog design The 1 87K series I O modules provides module watchdog and host watchdog The module watchdog is a hardware watchdog the host watchdog is a software watchdog The module watchdog is designed to automatically reset the microprocessor when the module hangs The host watchdog monitors the host controller PC or PLC The output of module can go to the Safe Value state when the host fails B Programmable power on and Safe Value The analog and digital output of modules can be programmed power on and Safe Value B Wide range power input 10 30 VDC Wide range operating temperature 25 C 75 Fully Software Support The free charge software utility and development kits include B DCON Utility for configuration File COM Port Search Eun Terminal H E E m m 255 Address 0 255 me ddress Baudrate Checksum Format Status Jm 115200 Disable N 8 1 Auto Contig Enable 0 0 0 0 4 5lot Auto Configuration US
35. he test Bright 3 One or more module test Module Status LED 1 Configuring Toler l Flashing per 100ms TO er Fail u Flashing per 2 second 2 Pass 1 0 08 Noto Green Auto Config Turn off ME LED 3 Fail USB 87P8 1 Auto Config On Bright CPU Module Flashing per 2 second LS 2 Auto Config Off Dark Fig 3 87Pn s CPU Module USB 87P1 2 4 8 User Manual Version 1 3 14 2 2 4 USB 87Pn series CPU Module Description Check the left side of the Power Board for the CPU module LED and Dip Switch description Default Setting e E pee USB 87P series CPU Board Description CE Fig 4 USB 87P1 2 4 8 CPU module description 2 2 5 Plug in the I O modules At present ICPDAS divides most of the same I 87K I O module into the Low Profile and High Profile two kinds of version If you want to use the module on 87Pn expansion slot you must choose the High Profile to assure Auto Config and Hot Swap function is normal operation The related product information about I 87K I O module is in the CD You can refer I 87K High Profile series I O modules in following path CD Napdos DCON IO Module 87k modules htm or to following web site ftp ftp icpdas com pub cd 8000cd napdos dcon io module 87k modules htm Example Plug in I 87019R to Slot 0 p s 87019R is an Al Analog Input High Profile module i 87019R is auto configured Baud Rate 115200 Net Address 2 Chec
36. know which port is connected Click the right button on My Computer icon gt property gt Hardware gt Add Hardware Wizard gt Device Manager Device Manager File Action View Help amp ICP168 Computer Disk drives ig Display adapters 2 DVD CD ROM drives E3 Floppy disk controllers H 3 IDE ATA ATAPI controllers 5 gt Keyboards Mice and other pointing devices Monitors 8 Network adapters 4 Ports COM amp LPT A Communications Port COMI F Communications Port COM2 CT S x COM3 SBR Processors an Tmi wel 12 ana mom mom m earntkvallav USB 87P1 2 4 8 User Manual Version 1 3 11 Note The old version of USB 87Pn with old USB chip show as below Es Device Manager E m x File Action view Help e Hem ICP168 Computer Disk drives i Display adapters DYD CD ROM drives 4 Floppy disk controllers 2 IDE ATAJATAPI controllers Keyboards y Mice and other pointing devices 2 Monitors HE Network adapters Ports COM amp LPT E Communications Port COMI 31 9 Sound video and game controllers System devices Universal Serial Bus controllers USB 87P1 2 4 8 User Manual Version 1 3 2 2 View of the USB 87PN Power Module CPU Module I 87K I O Slots 87Pn power CPU power System ready p Auto silane Enable Disable olot
37. ksum Disable Net Address 1 2 3 Fig 5 Plug in the l O module USB 87P1 2 4 8 User Manual Version 1 3 15 After plugged in the slot indicator is flashing per 100 ms When configuration is completed the LED becomes off If configuration is failed the LED is USB 87P4 always on CPU Module Fig 6 Description of LED indicator 2 2 6 Wiring the I O modules Before wiring the I 87K I O modules please check the pin assignment and wiring according to each hardware user manual For each I 87K I O module s hardware user manual please refer to CD Napdos DCON IO_Module 87k_ modules htm According to the internal circuitry diagram and wire connection diagram please connect the power cable or communication cable to each channel on terminal block of I O module Temperature Sensor LED module Photo c Embedded DADO RxD E ADC Isolation 5 Controller 2 Pr EEPROM 5V GND Fig 7 87019R Internal I O structure USB 87P1 2 4 8 User Manual Version 1 3 16 e e o o e e o e e e e e e e e b Pin Assignment Voltage Input Wiring Name VinO VinO Vin1 Vin1 Vin2 Vin2 Vin3 Vin3 Vin4 Vin4 Vin5 Vin5 Vin6 Vin6 Vin7 Vin Terminal No Fig 8 87019R Pin assignments amp Wire Connection Terminal Block SN ur JE IE RAR xx a 4 all all sal he Ec Fa a J he ak a be e a ie Pa e E Fr Hl pO Gu Up US CUu POUR Uo
38. lue The following is an example of reading analog values from an 1 87018 inserted in slot O of an USB 87P1 2 4 8 User Manual Version 1 3 43 8410 8810 Step 1 Run the DCON Utility to configure the I O modules Step 2 Run the OPC Server to search for l O modules on COM1 Clear Modules 6 4115200 057600 38400 19200 9600 C4800 E2400 1200 Address 110 255 Checkum Timeout mSec Start fo Disabled 500 End 55 Enable tatus 0 4 0 B 9600 1 EC 13 2 mE am search Expand Shrink Monitor TI S t Be New Open Save Device Group Analog Output 2 choi Analog Output 1 2 Ch02 Analog Output 2 2 cho3 Analog Output 3 Step 3 Save the configuration and close the OPC Server Step 4 Run SCADA software to connect to the OPC Server The OPC Server user s manual lists the procedures for the following SCADA software mw LabVIEW W National WIZCON M ir ja mauson jg Citeo Please refer to Chapter 4 Connecting to the OPC Server for more details USB 87P1 2 4 8 User Manual Version 1 3 44 Appendix A Dimension A 1 USB 87P1 Auxiliary View 110 0 Ce an cC T LE OLIL E ILIL E E ILI GO J ro 3 mp a ILL Front View Right Side View USB 87P1 2 4 8 User Manual Version 1 3 45 A 2 USB 87P2 Unit mm ii 3 wee ee i ye m E A ASAS gt 7 ma te r a BER Front View Right Side View USB 87P1
39. nd out the USB 87P4 and a 87019R which on slot 0 the Status column shows Auto Config Enable 0 X X X File COM Port Search Run Termmal H al E gt u m End 255 Address 0 255 A Fig 27 The search result between 87Pn and modules Click the name USB 87P4 entering the operation screen to know the settings of 87Pn and the status detected by 87Pn CPU the module status code in Slot Configuration Slot column means the different error message A Configuration for 774 Module Version A202 8 P4 Hot Swap and Auto Configuration scanned I O on Slot 1 0 Write To 87P4 Addr Hex Slot Configuration Status Set As Scanned write To 87P4 18701 9 Oe 00H OK Copy Configure 87019R 1 87024 y 03 06H Can nat find module Copy Configure Empty 2 87055 y Bars 07H Incorrect module name Copy Configure 87024 NELLE 3 Empty 05 IMH MeduescannedinEmptyslot Copy Configure 87055 zd B 5 05 tef Configure zd B 2 q A Configure zd B 5 o Configure zd B 5 582 E METEO save Configuration Load Configuration Load Configuration And Write To 87P4 rer You may click Help to inquire the solution and the meaning of error code USB 87P4 CPU Module Fig 28 DCON Utility shows the status of 87Pn expansion slot As following table you can accord the error code and LED lamp status to find out the problem solution USB 87P1 2 4 8 User Manual Ve
40. o H EP Slot 0 Slot 1 oa 2 Ed 98 574 I ro Unit i H DC 10 30V E E 22 Los o t see n see i r t X sae J eee USB 87P4 j CPU Modute gt E hd 1 4 om _ Power USB Slots LED indicators connector connector J Fig 1 View of 87Pn 2 2 1 Preparation Power Supply 10V 30V DC Ex DP 665 http www icodas com products Accessories power supply power list htm gt CA USB18 USB connector cable 1 8M Cable http www icodas com products Accessories cable cable selection htm gt Install the DCON Utility to PC Version 4 5 2 or above version CD Napdos Driver DCON_ Utility or ftp ftp icpdas com pub cd 8000cd napdos driver dcon utility Please removed the old version before installation USB 87P1 2 4 8 User Manual Version 1 3 13 2 2 2 Wire the 87Pn to power and PC USB 87P4 1 Vs Power Supply Vs 10 30V 2 GND Power Supply GND 3 CA USB18 PC s USB port Power Supply 10 30V DC DC 10 30V I i ee NM ai 3 1 E ij H ee E zu USB 87P4 Fig 2 Wire the 87Pn to power and PC T 2 2 3 USB 87Pn s CPU module The factory default value is Auto Config ON System LED Red PWR LED 1 Power On Bright 2 Power Off Dark O Green S RDY LED Auto Config 1 Any module configuring Flashing per 100ms 2 All of the modules pass t
41. onfigure Save file ccooocccccocnccccnonoconnnonanononanoconannnos 30 Fig 24 Load configure file in another PC sasarina a aG 31 FIg 25 Wiete setings to USB to e o eso tius dos 32 Fig 26 1 87K high low profile series l O modules eeseeeeeeees 49 Fig 27 The search result between 87Pn and modules oocccccocccconccccnnccconncoconacoconaciconcnnns 50 Fig 28 DCON Utility shows the status of 87Pn expansion slot 50 Fig 292 Frame Ground Ehh OFOUFIC iii 56 USB 87P1 2 4 8 User Manual Version 1 3 3 Chapter 1 Introduction USB 87Pn series is a intelligent I O expansion unit it features USB communication interface hot swap and most of all this I O unit can expand its functions by putting in any kind of l 87K series High profile modules It used for industrial monitoring and controlling applications There are more than 30 I O modules supported with the unit including analog input output digital input output and counter frequency I O modules USB 87Pn is designed to be used in harsh and noisy environment so the hardware is manufactured with wide power input range 10 30VDC and operating temperature 25 C 75 It simplifies installation and maintenance of I O modules with hot swap and auto configuration fault and error detection dual watchdog programmable power on and Safe Values Various software development kits SDK
42. rsion 1 3 90 Table 1 The Error Code in Auto Config Enable mode Error Slot LED Description Code Red j Dark ok Ok PK 1 There is a module scanned in this empty i Remove the module setting slot Module Reconfigure it with DCON Utility scanned in Empty Slot 2 The first time to setup no initial value 1 Click Set As Scanned button and configure module again 2 Click Write To 87Pn button to write settings to 87Pn Configure failure 1 Check the 1 87K I O module s firmware This is a 87K 1 0 module firmware Run Dcon Utility gt Terminal gt Dcon command Line Flashing Warning Commands compatibility problem setup Baud Rate gt Command AAF EX 01F gt Send Flashing E Warning comparable Some commands at this slot might be too You can see the version Respond 01A1 9 new for this old firmware of 87K I O module but it is not serious for system operation 2 Update the 87K I O module with a new firmware version Configure failure Bright Configuration Some commands are not supported by this Error Failed 87K I O module and this error will be serious for system operation Configure failure wrong 1 Run DCON Utility Configuration The format of configured commands is 2 Click the Write To 87Pn button to write the settings to format wrong for DCON Protocol 87Pn CPU again Bright The memory data is failed 1 Run DCON Utility 1 Check the 87K I O module firmware 2 Upd
43. s Complement Format CHANNEL ENABLE STATUS amp hFF Slot0 ID 87019R Section 4 The Configuration Commands TOTAL 1C for each slot C00 2502000A0221F USB 87P1 2 4 8 User Manual Version 1 3 55 Appendix E Frame Ground Electronic circuits are constantly vulnerable to Electro Static Discharge ESD which become worse in a continental climate area Some l 7000 M 7000 and l 8000 series modules feature a new design for the frame ground which provides a path for bypassing ESD allowing enhanced static protection ESD capability and ensures that the module is more reliable The following options will provide a better protection for the module The USB 87Pn controller has a metallic board attached to the back of the plastic basket When mounted to the DIN rail connect the DIN rail to the earth ground because the DIN rail is in contact with the upper frame ground as shown in the Figure 29 below Connect to the Earth Ground Fig 29 Frame Ground amp Earth Ground USB 87P1 2 4 8 User Manual Version 1 3 56
44. sion 1 3 6 1 1 Specifications B Interface Type Full speed with USB 1 1 specifications Cable USB type A connector Baud rate 115200 bps default fixed 3000 VDC 4K Contact Discharge and 8K Air Discharge Min oio Cm Uo O5 D Q 5 DIP Switch B LED Indicators Power Yes 1 bit 1 For auto configuration Yes es lot Status Yes m I O Expansion Slots Hot Swap ystem Ready 00 D gt W O C O 2 2 S 2 es Auto Configuration Yes upport Module Type Dimensions W x H x D USB 87P1 slot x 1 USB 87P2 slot x 2 USB 87P4 slot x 4 USB 87P8 slot x 8 High profile I 87K module only 64mm x 117mm x 110mm o AU AAA lt gt 95mm x 132mm x 111mm ae 188mm x 132mm x 111mm 312mm x 132mm x 111mm Input Range 10 30 VDC non regulated Yes 1000 VDC Yes Module USB 87P1 USB 87P2 USB 87P4 USB 87P8 Consumption Power Board Driving 2 W 2 4 W 15W 30 W no me JE DIS IN oa 5s G oO e D O oO O pL D O O D Bl m 5 O 5 3 O 2 25 C to 75 C torage Temperature 30 C to 75 C Humidity 5 95 non condensing RIO Oo O x zi e D 3 Oo O x Cc um USB 87P1 2 4 8 User Manual Version 1 3 Chapter 2 Hardware Configuration 2 1 Install USB Driver Before you setup the USB 87Pn you must install USB driver Refer to below path CD Napdos 87pn_io_unit USB 87Pn ftp ftp
45. the settings and replies the normal operation Note In DCON Utility search screen the message in status column of 87Pn The meaning of Auto Config Enable 0 X 0 0 as following description 0 Means the module configuration on this slot is successful or have no module X Means the module configuration on this slot is uncorrected If the status column of 87Pn shows Auto Config Enable 0 0 0 0 means the Auto Config of Dip Switch is switching to the On and the I O configuration of each slot is correct or has no module If the status column of 87Pn shows Auto Config Disable 0 0 0 0 means the Auto Config of Dip Switch is switching to the Off and the l O configuration of each slot can initialization success or have no module 3 2 Save amp Load 87Pn Configure file When you completed the module configuration you can press Save Configuration to save all the settings of related modules It can be use for system recover and system backup In addition you can press Load Configuration to load the prior configuration file The related format and detail about configure file please refer to Appendix D USB 87P1 2 4 8 User Manual Version 1 3 23 3 2 1 Save the Configure file When all modules has configured properly you could save the settings as a file to avoid the settings is carelessly changed or need to duplicate the same content of configure You can refer 3 1 1 to configure the modules
46. tion is enable off means disable Working Distinction If 1 87K I O modules didn t pass the 87Pn correct setup and install into expansion slot under Auto Config Enable mode it will regard as incorrect module For guarantee system s normal operation the 87Pn will forbid this module external communication You can t search and configure I O modules directly by DCON Utility The Auto Config Enable X X X X l in Status column means the module configuration of that slot is not completed or corrected Click USB 87P4 and select Configure Module to enter configure screen and know the detail settings about module File COM Port Search Run Terminal Help aie rr en Stat 0 End 255 Address 0 255 Format Sti Description USB 8rP4 1 1 175200 Disable N 8 1 Auto Config Enable 525 5X 4 Slot Auto Configuration USB Unt DCON ee Fig 12 Auto Config Enable setup the 87Pn In 87Pn configure screen you can see the scanned module name in Scanned I O on Slot column Click Set As Scanned button to assign module name and click configure to setup the I O module according to the user demand Finally click write to 87Pn for the settings to take effect 8 P4 Hot Swap and Auto Configuration mmm I O on E YO Write To 87P4 Addr Hex I Emmy 0 2 my me NENNEN A Fig 13 Follow 3 steps write the settings to 87Pn USB 87P1 2 4 8 User Manual Version 1 3 21

Download Pdf Manuals

image

Related Search

Related Contents

Digitus KVM Extender    Burnham Series C Power Flame Low NOx Data Sheet  CAN Fiber Optic Bridge User Manual  Samsung J708i 用户手册  

Copyright © All rights reserved.
Failed to retrieve file