Home
Installation Instructions for V Series Cylindrical Locks
Contents
1. gt a pan a gE N 1d ACCESS SYSTEMS Installation Instructions for V Series 83KV 93KV 85KV 95KV Locksets Overview Figure 1 a Position template Note On steel frame applications align the horizontal centerline of the latch with the horizontal centerline of the strike preparation For uncut doors Fold the template along the perforation and carefully place it in posi tion on the high side of the door edge bevel The suggested height from the floor to the centerline of the lock is 38 For doors with standard cylindrical preparation Looking through the hole from the opposite side of the door align the template so that you see the template outline of the 2 1 8 diam eter hole Tape the template onto the door Center punch the drill points 2 Drill holes and install latch Note 1 f the door is a fabricated hollow metal door determine whether it is properly reinforced to support the lock If the door rein forcement is not adequate consult the door manufacturer for informa tion on proper reinforcement Note 2 To locate the centerpoint of a hole on the opposite side of the door drill a pilot hole completely through the door Note 3 For through holes it is best to drill halfway from each side of the door to prevent the door from splintering Drill the 3 8 diameter hole through the door for the motor wires Bore the 2 1 8 diameter hole if not already bored Drill the 1 diamete
2. levers 1 For the inside and outside levers With the lever pointing toward the hinges push firmly on the lever until it is seated For the inside and outside knobs Push firmly on the knob until it is seated 2 Tighten the trim mounting screws see Figure 12 3 Turn the knobs levers to check that they operate smoothly Figure 15 Install strike plate Caution The deadlocking plunger of the latchbolt must make contact with the strike plate as shown in Figure 16 The plunger deadlocks the latchbolt and prevents someone from forcing the latch open when the door is closed Deadlocking plunger Ye Strike pe P Figure 16 1 In alignment with the center of the latch bolt mortise the door jamb to accommo date the strike box and strike plate 2 Insert the strike box and secure the strike with the two screws provided a One half door thickness K Door stop pa oa Door frame Figure 17 Install core and throw member 1 Install the blocking plate onto the throw member Caution You must use the blocking plate to prevent unauthorized access Blocking plate Throw oe member Figure 18 2 Insert the control key into the core and rotate the key 15 degrees to the right T61852 Rev 1852777 ER 7991 1 3 Insert the core and throw member into the knob or lever with the control key 4 Rotate the control key 15 degrees to the left and withdraw the key Note Be su
3. the door 4 Insert and turn the key to unlatch the door For proximity card electronic locks 1 Place the temporary operator card in front of the proximity reader see Figure 21 The green light flashes and the locking mechanism unlocks Figure 21 2 Turn the lever or knob and open the door 3 Insert and turn the key to unlatch the door If the mechanism doesn t unlock refer to the following table LEDs Sounder Access You should 1 long Denied Use the token at tone a moderate speed Green Denied Use the tempo stays rary operator on token not the temporary com munication token Green Denied Connect the flashes motor wires Denied Connect the battery and con nect the out side wire harness
4. this connect only the connectors with matching wire colors 4 Making sure that the connector is properly aligned connect the outside wire harness connector to the lower right circuit board connector in the inside trim Press firmly on the connector until it is fully seated Wire harness Wire harness mating connector Mating connector Motor connector Figure 11 T61852 Rev 1852777 ER 7991 1 10 Secure the trim 1 Pull the excess outside wire harness back through to the outside trim 2 Position the inside and outside trim onto the door 3 Making sure that the trim does not pinch the wires secure the trim to the door but do not tighten with the combination mounting screw at the top mounting hole and with the standard screw at the bottom mounting hole Combination yi mounting Ty screw Standard r mounting Ty screw Figure 12 11 Connect battery pack 1 Connect the battery pack to the connector hanging inside the battery compartment 2 Insert the battery pack into the battery compartment so that the foam will face the battery door Figure 13 BEST ACCESS SYSTEMS Indianapolis Indiana Install battery compartment door 1 Insert the tabs of the battery compartment door into its mating slots and swing the door closed 2 Secure the battery compartment door with the security screw Tighten firmly we a screw Figure 14 Install inside and outside knobs
5. ght hole and into the knob lever keeper 4 Press the screwdriver blade in the direction of the arrow in Figure 5 Note You will not be able to remove the knob lever if the screwdriver blade is inserted too far past the keeper 5 Slide the knob lever off the sleeve Insert screwdriver blade here Knob lever keeper a ae a fa S Figure eight core hole Figure 5 5 Adjust to door thickness 1 Determine the door s thickness 2 Pull the rose locking pin and rotate the outside rose liner until the proper groove on the through bolt stud lines up with the hub face 13 4 x Grooves on through bolt stud a Pull rose locking pin to rotate rose Figure 6 T61852 Rev 1852777 ER 7991 1 Note 1 Make sure that the locking pin fully locks into the rose liner Note 2 Locksets will fit doors 1 3 4 to 2 1 4 thick A spacer is available for 1 3 8 doors See the enlarged view for the correct rose adjustment for these thicknesses While feeding the motor wires through the 3 8 hole to the inside of the door insert the lock chassis into the hole Caution Be sure that the latch tube prongs engage the chassis frame and that the latch tailpiece engages the retractor Enlarged view ee Retractor eo ne _ y Latch tube j Latch prongs tailpiece Chassis lt lt Figure 7 Ym Install through bolts and rose liner 1 Making sure that the motor wires come
6. r hole into the edge of the door to meet the cen ter of the 2 1 8 diameter hole if not already drilled Drill the two 5 8 diameter holes for the trim and one 7 8 diameter hole for the wire harness Mortise the edge of the door to accommodate the latch face Install the latch and check that the door swings freely Drill the 7 8 diameter hole for the wires Note The latch tube prongs should be centered and should project into the 2 1 8 diameter hole as shown in Figure 7 5 8 diameter NG NU diameter ON diameter ST A 1 8 diameter 5 8 diameter Install boring jig and drill two 5 16 diameter holes Press the boring jig KD303 onto the door engaging it with the latch tube prongs Make sure that the front edge of the jig is parallel with the door s edge D 5 16 diameter Sy diameter 1 diameter Latch face o 9 Figure 3 1 Latch tube prongs Figure 2 Figure 4 T61852 Rev 1852777 ER 7991 1 BEST ACCESS SYSTEMS 1 Indianapolis Indiana 2 Drill two 5 16 diameter holes halfway into the door 3 Turn the boring jig over and repeat steps 1 and 2 from the opposite side of the door Note Replace the boring jig after 10 door preparations UE Remove outside knob lever 1 Insert the control key into the core and rotate the key 15 degrees to the right 2 Remove the core and throw member from the knob lever 3 Insert a flat blade screwdriver into the fig ure ei
7. re to insert the correct throw member into the core six pin cores require the number 6 throw member seven pin cores require the number 7 throw member Caution The control key can be used to remove cores and access doors Provide adequate security for the control key Figure 19 16 Test lock To test the lock for proper operation use the temporary operator card or personal identifi cation number PIN that came with the lock This card or PIN is for temporary use only and once permanent cards or PINs have been pro grammed for the lock you should delete the temporary cards or PINs These temporary operator cards and PINs will only work on factory default V Series locks For details on programming the lock for access control refer to the V Series Intelligent Programming Software User Manual or the V Series Handheld Terminal User Manual For magnetic stripe card electronic locks 1 With the temporary operating instructions facing toward you insert and remove the temporary operator card see Figure 20 The green light flashes and the locking mechanism unlocks 2 Turn the lever or knob and open the door 3 Insert and turn the key to unlatch the door Figure 20 BEST ACCESS SYSTEMS Indianapolis Indiana For keypad electronic locks 1 Enter the temporary operator PIN 99998 on the keypad 2 Press 2 The green light flashes and the locking mechanism unlocks 3 Turn the lever or knob and open
8. through the notch in the 2 1 8 hole align the holes in the liner with the holes pre pared in the door Caution Make sure that there is clear ance for the motor wire between the rose liner and the door Hub Ri b gt F D skew Inside liner Figure 8 BEST ACCESS SYSTEMS Indianapolis Indiana 2 Install the through bolts through the liner and door in the top and bottom holes 3 Tighten the liner onto the door with the through bolts Install trim hole inserts bushings and hub washers 1 Insert the two trim hole inserts into the upper trim hole on each side of the door see Figure 9 2 Insert the two bushings into the wire hole on each side of the door see Figure 9 3 On each side of the door slide a hub washer over the chassis sleeve so it rests on the hub Bushing Trim hole insert Bushing oY SO Hub washer Trim hole insert Figure 9 9 Make wire connections 1 Feed the outside wire harness connector through the top wire hole see Figure 10 Wire hole Outside wire harness Figure 10 2 Temporarily rest the trim on the door by inserting the trim studs into the stud holes 3 From the inside of the door connect the motor connector to the mating connector from the circuit board see Figure 11 Note It is possible to plug the battery pack into the motor connector and the motor wire into the battery connector To avoid
Download Pdf Manuals
Related Search
Related Contents
Scarica il libretto istruzioni - Hotpoint Spectacles de tango dansé : petit parcours initiatique LoiLoScopeEX/AX/FX Benutzerhandbuch Sie können auf das C706 Kensington Pro Fit Mobile ZS-2000 Bedienungsanleitung ZK 246 / M 2404 S / M - NEW HiFi Anleitung - CONRAD Produktinfo. Buhler FK366 Tiller User Manual Copyright © All rights reserved.