Home

DIMEScript User Guide - Electronic Systems group

image

Contents

1. clockset clock frequency Set one of the onboard clocks to given frequency in KHz Clocks are defined as 0 All clocks S YSCLK 2 DSPCLK 3 PIXCLK config module device lt bitfilename gt Configure specified device on specified module with specified bitfile callext lt libname gt lt routinename gt Calls an external function dimecall or lt routinename gt if specified in lt libname gt dll Routine should have the following declaration __declspec dllexport DWORD dimecall DIME HANDLE cardhandle DWORD dataarea DWORD dataareasize DWORD numareas closecard Closes the currently open board dsize Dn lt size gt Sets the size in words of data area Dn If no size is specified then reports current size of data area Dn delay lt milliseconds gt Delays execution for specified time endloop now Indicates the end of a loop If optional parameter now is given then loop is completed immediately not based on loop variable eprint statements Print the following items to the error message handler NT107 0103 2 21 DIMEScript User Guide else Indicates the else clause of an if statement endif Indicates the end of an if statement fpgareset eld Enables or disables the FPGA also known as virtex reset pin If no parameter is given pulses pin for 100ns fprint filename aln statements Prints the given statements to the given
2. DIMEScript User Guide NT107 0103 2 37 DIMEScript User Guide 8 1 Debug Techniques The simplest and most effective debug technique is to insert the line verbose y in the script above where the problem is known to occur This causes DIMEScript to output diagnostic information regarding how it is interpreting the script This often shows that the interpretation is incorrect due to a subtle syntax error or similar 8 2 Common Questions Title Unable to open card Title Exception Read Error in Module nueym dll Question The DIMEScript reports that the card cannot be opened Question When running DIME software we got the following error Exception ReadError in module nueym dll at 00061041 Answer Check that the card is in fact installed Check that the device drivers are correctly installed Answer The software requires a printer driver installed on the PC itis operating on even if there isn t a printer attached Install a printer driver 8 3 Technical Support Contact If you are contacting technical support it is helpful if you can provide the following details e The Nallatech product you are using e Any module specific options such as AC coupling on ADC based modules e The serial number if known e The operating system and installed service pack you are running if applicable e Whether or not the demo files run successfully e What design tools you are using and what version and
3. Dn load Dn filename size loadb Dn filename lt offset gt lt size gt led value loop lt numberiterations gt lt initialvalue gt lt increment gt opencard PCI USB lt boardnumber gt pcireset printconfig lt filename gt print lt statements gt quiet yIn quit readdata lt size gt Dn lt offset gt lt columns gt readio Dn readtalk lt endpoint gt lt address gt lt size gt Dn lt offset gt lt columns gt random Dn lt size gt save Dn filename a n columns lt size gt saveb Dn filename lt offset gt size setdirio Dn lt data gt sysreset eld silent y n setvar variable value timeout lt timeoutlength gt timing y n verbose y n version writeaddr lt address gt writedata size Dn lt offset gt d0 lt d1 gt 16 NT107 0103 2 DIMEScript User Guide writeio Dn lt value gt writetalk endpoint address size Dn lt offset gt lt d0 gt lt d1 gt NT107 0103 2 17 DIMEScript User Guide Software Description In this section General Command Reference API Reference Dimecontrol application usage Software Interfacing Considerations NT107 0103 2 DIMEScript User Guide NT107 0103 2 19 DIMEScript User Guide 5 1 General DIMEScript is an interpreted language For convenience there are assumed to be 16 data areas defined These are indicated as DO Df for use i
4. any country prohibited by the United States Export Administration Act 1969 as amended and the regulations there under or be used for any purpose prohibited by the Act User Guide Conditions Information in this User Guide is subject to change without notice Any changes will be included in future versions of this manual Information within this manual may include technical typing or printing inaccuracies or errors and no liability will arise therefrom This user guide is supplied without warranty or condition either expressed or implied including but not limited to any implied warranties of merchantability and fitness for a particular purpose regarding the information provided herein Under no circumstances will Nallatech Limited be liable for any incidental or consequential damage or expense of any kind including but not limited to loss of profits arising in connection with the use of the information provided herein NT107 0103 2
5. area or size if given If file is smaller than required size then file is repeatedly used until area has been filled loop lt numberiterations gt lt initialvalue gt lt increment gt Perform the code between this and the next endloop statement numberiterations times unless endloop now is encountered The loop variable can be given an initial value and increment for use within the loop Loops may be nested to a depth of 10 opencard PCIIUSB lt boardnumber gt Opens card on specified interface If not given then interface defaults to PCI If not given then boardnumber defaults to 1 boards are numbered from 1 pcireset Reset the PCI core printconfig lt filename gt Print out the current configuration of the board to the standard print handler or optionally to the specified file print statements Print the following statements to the standard print handler quiet vin Temporarily enable or disable the standard print handler If no parameter is given the print handler is disabled i e default is y quit Exit the current script readdata size Dn lt offset gt lt columns gt Read data from the card size words are read If a data area is specified then data is stored in this area at the optional offset If no data area is specified data is printed to screen in specified number of columns NT107 0103 2 23 DIMEScript User Guide readio Dn Read the dedicated I O p
6. can be accepted for non compliance with them Delivery shall be made by the company using a courier service of its choice The cost of the delivery plus a nominal fee for administration will be added to the invoice issued Payment of all inward customs duties and fees are the sole responsibility of the buyer If multiple shipments are requested by the buyer multiple delivery charges will be made In the case of multiple deliveries separate invoices will be raised If requested at the time of ordering an alternative delivery service can be used but only if account details are supplied to the company so that the delivery can be invoiced directly to the buyer by the delivery service The buyer accepts that any to be advised scheduled orders not completed within twelve months from the date of acceptance of the NT107 0103 2 DIMEScript User Guide original order or orders held up by the buyers lack of action regarding delivery can be shipped and invoiced by the company and paid in full by the buyer immediately after completion of that twelve month period INSURANCE All shipments from the company are insured by them If any goods received by the buyer are in an unsatisfactory condition the following courses of action shall be taken If the outer packaging is visibly damaged then the goods should not be accepted from the courier or they should be signed for only after noting that the packaging has sustained damage If the good
7. file a indicates Append to file n indicates New file forward lt numlines gt Jump forward in current file by lt numlines gt or to end of file whichever is sooner goto lt linenumber gt Go to specific line number in current file help lt command gt Print help on a specific command If command is omitted then all commands are listed if Dn amp lll lzi i i lt value gt IDn Standard if statement based on the comparison between the first words of two data areas or one data area and a value Comparisons supported are amp Logical and Logical or Logical exclusive or Equality gt Greater than lt Less than A non zero value for logical functions is true If test is false execution recommences at else or endif statement whichever is sooner led lt value gt Set board LEDs to given value Note that on most motherboards there are four LEDS so only bottom nibble is valid Note also that LEDS are in effect inverted so Oxf switches LEDS off and 0x0 switches them on 22 NT107 0103 2 DIMEScript User Guide load Dn lt filename gt lt size gt Load data area Dn from text file File is assumed to be comma delimited Loads full data area or size if given If file is smaller than required size then file is repeatedly used until area has been filled loadb Dn filename lt offset gt size Load data area Dn from binary file File is assumed to contain binary data Loads full data
8. part of the goods which has 47 DIMEScript User Guide been modified without Nallatech s prior written consent or which has been subjected to unusual physical or electrical stress or on which the original identification marks have been removed or altered Nor will such warranty apply if repair or parts required as a result of causes other than ordinary authorised use including without limitation accident air conditioning humidity control or other environmental conditions Under no circumstances will the company be liable for any incidental or consequential damage or expense of any kind including but not limited to personal injuries and loss of profits arising in connection with any contract or with the use abuse unsafe use or inability to use the companies goods The companies maximum liability shall not exceed and the customers remedy is limited to either i repair or replacement of the defective part or product or at the companies option ii return of the product and refund of the purchase price and such remedy shall be the customers entire and exclusive remedy Warranty of the software written by the company shall be limited to 90 days warranty that the media is free from defects and no warranty express or implied is given that the computer software will be free from error or will meet the specification requirements of the buyer The terms of any warranty offered by a third party whose software is supplied by the company
9. screen Congratulations DIMEScript has been successfully installed 3 1 2 Hardware Software Interface Check If you have a card installed in the machine on which DIMEScript has been installed scripts have been provided to perform simple card interface checking Scripts are named card virtex dsc indicating the type of card installed and the type of virtex populated on the card For example a Ballynuey with Virtex V600e would use the script ballynuey v600e dsc Choose the appropriate script and type DOS gt dimescript lt scriptname gt dsc Linux gt dimescript lt scriptname gt dsc The output from this script will be similar to Performing script commands from ballynuey_v600e dsc Card 1 serial no 121091 opened on PCI bus Nallatech Card Configuration Motherboard type Ballynuey II Multiple configuration license Virtex to PCI Buffer Empty PCI to Virtex Buffer Empty Module 0 Onboard Virtex Device DIME code 0x0 with 1 devices Device 0 Xilinx Virtex XCV600E IDCODE 0x80a30093 Loading ping design Set all clocks 0 to 40 000MHz actually 40 000MHz Loaded module 0 device 0 with bitfiles nueyping2_V600e bit allatech Card Configuration otherboard type Ballynuey II ultiple configuration license Virtex to PCI Buffer Empty NT107 0103 2 11 DIMEScript User Guide PCI to Virtex Buffer Empty Module 0 Onboard Virtex Device DIME code 0x0 with 1 devices Device 0 Xilinx Virtex X
10. 07 0103 2 DIMEScript User Guide NT107 0103 2 33 DIMEScript User Guide 7 1 Design Process 7 1 1 Use of Data Areas and Variables As DIMEScript is an interpreted language particular care must be taken to define use of variables and data areas rigidly to allow easy debug It is suggested that prior to producing a script the various variables 0 255 be assigned an appropriate function as necessary In addition the Data areas 0 F should be assigned particular functions For example Variables 0 Size of transfer buffer 1 Number of free units 2 to 255 Unused Data Areas DO Read array D1 Write array D2 Initialisation data If the whole design adheres to this initial definition the possibility of unfortunate contamination of used variables or data areas is lower 7 1 2 Use of Subroutines DIMEScript does not directly allow for parameter passing to subroutines However careful use of the inbuilt variables see above can be used for this purpose Generally it is advisable to use subroutines where a function is clearly a re useable and definable subset of the function of the whole system An example is the viread and viwrite subroutines used in the example delivered 34 NT107 0103 2 DIMEScript User Guide NT107 0103 2 35 DIMEScript User Guide Troubleshooting In this section e Debug Techniques e Common problems and solutions e Contacting technical support 36 NT107 0103 2
11. 6 6 Getting Software Using Trouble Started Overview Description shooting Section2 Section3 Section 4 Section5 Section6 Section7 Section 8 Section 9 XIII 0729 0 7 Installation Tutorials Appendices ee I I ar The green path is best for those who wish to learn about the product and it s functionality before installing it Users with previous experience of the DIMEScript may only require to refer to selected sections Details of the information contained in the different sections of the user guide are given below and on the following page Designing Tutorials with the rou shooting Getting Software Installation Appendices Started Overview Description Details the installation of the DIMEScript software and particular system requirements If you want to install the DIMEScript software start reading Section 2 Installation Guide Designing Tutorials with the pue shooting Getting Software Installation Appendices Started Overview Description Describes the basic confidence tests of the hardware to ensure that the hardware and software have been installed correctly in the host system For some basic tests start reading Section 3 Getting Started Designing Tutorials with the Trouble shooting Getting Software Installation Appendices Started Overview Description For an overview of the functionality provided by the DIMEScript start reading Sect
12. CV600E IDCODE 0x80a30093 bitfiles nueyping2_V600e bit Testing card transferring 64 values Board testing completed successfully Note that this script assumes a bare motherboard i e no modules If modules are present then the command in the script file resembling config 0 0 bitfiles nueyping2_v600e bit should be changed to config lt x gt 0 bitfiles nueyping2_v600e bit where x is equal to the number of modules on the card i e 1 module means x 1 12 NT107 0103 2 DIMEScript User Guide Product Overview In this section e Key features e Overall functional diagram e Available commands NT107 0103 2 13 DIMEScript User Guide 14 NT107 0103 2 DIMEScript User Guide 4 1 DIMEScript Key Features DIMEScript has been developed by Nallatech as a means of simply accessing cards without the need to resort to C programming It is an interpreted language This means that the language is read in line by line and appropriate actions taken This in turn means that any errors in the script are only found when the relevant line is executed This is in contrast to a compiled language where the required action is checked in advance and made into a more machine friendly form In the case of the compiled language syntax etc can be fully checked before running the code DIMEScript allows users to Open a Nallatech card Read data from the card Write data to the card Access various specific card function
13. DIMEScript User Guide NT107 0103 Issue 2 DIMEScript User Guide NT107 0103 2 NALLATECH Contacting Us Support WWW Mathworks DIMEScript User Guide Nallatech is the leading high performance FPGA solutions provider with unrivalled industry expertise in software defined systems Nallatech s industry leading products and services are used in many application areas including Broadband Comms Wireless Gigabit Comms HWIL hardware in the loop 3D Simulators Video amp Image Processing PCI and Data Compression Nallatech offers design services of complete systems in addition to the modular DIME and DIME II product ranges for electronic systems VIRTUAL COMPONENT www nallatech com support index htm Email support nallatech com Nallatech Boolean House One Napier Park Cumbernauld GLASGOW G68 OBH United Kingdom Phone Fax Europe Corporate Headquarters Phone 44 0 1236 789500 Fax 44 0 1236 789599 USA Phone 1 407 384 9255 Fax 1 407 384 8555 Email WWW NT107 0103 2 info nallatech com www nallatech com DIMEScript User Guide Document Information Document Name DIMEScript User Guide Document Number NT107 0103 Issue Number 2 Date of Issue 25 04 2003 Trademark Information The Nallatech logo DIME and DIMEScript are Trademarks of Nallatech Limited The Algorithms to Hardware Company Software defined
14. Systems and Making Hardware Soft are Service Marks of Nallatech Limited All products or brand names mentioned herein are used for identification purposes only and are trademarks registered trademarks or service marks of their respective owners Copyright Information This document which is supplied in confidence is the copyright property of Nallatech Limited Neither the whole nor any extract may be disclosed loaned copied or used for any purpose other than those purposes for which written permission was given at the time of release Application for any uplifting or relaxation of these restrictions must be made in writing to Nallatech Limited who may at their discretion refuse such application or give it qualified or absolute approval Copyright 1993 2001 Nallatech Limited All Rights Reserved iv NT107 0103 2 TABLE OF CONTENTS PREFACE 1 1 About User s Guide 1 2 Navigating this User Guide 1 3 References 1 4 Abbreviations INSTALLATION GUIDE 2 1 Product Items Checklist 2 2 Software amp Hardware Requirements 2 3 Software Installation Guide Windows 2 4 Software Installation Guide Linux GETTING STARTED 3 1 Software Confidence Check 3 1 1 Basic Software Check 3 1 2 Hardware Software Interface Check PRODUCT OVERVIEW 4 1 DIMEScript Key Features 4 2 Overall Functional Diagram 4 3 Available Functions SOFTWARE DESCRIPTION 5 1 General 5 2 Use of Variables 5 3 Command Reference 5 4 API Re
15. ed 10 would be interpreted as setvar 10 12 led 12 24 NT107 0103 2 DIMEScript User Guide timeout lt timeoutlength gt Set the default timeout for transfers to from the card to specified time in ms If no parameter is given then the current timeout is printed timing yln If enabled all commands are timed and the results output If no parameter is given then assumed to be y writedata size Dn lt offset gt l d0 d1 Write the specified number of words to the card Words can either be from specified data area or explicitly listed in script If a data area is specified an optional offset can be given Data is then written from the data area from the given offset writeaddr address Write an address to the card writeio Dni lt value gt Write out on the I O pins of the Ballynuey and Ballynuey II cards writetalk endpoint address size Dn lt offset gt I lt d0 gt lt d1 gt Write the specified number of words to the card via the DIMETalk protocol Words are written to endpoint endpoint at address address Words can either be from specified data area or explicitly listed in script If a data area is specified an optional offset can be given Data is then written from the data area from the given offset NT107 0103 2 25 DIMEScript User Guide 5 4 API Reference There are two functions exported from the shared library dimescript dil for windows dimescript so f
16. ference 5 5 Dimecontrol Application Usage 5 6 Software Interfacing Considerations 5 6 1 General 5 6 2 Linux Specific 5 6 3 Windows Specific TUTORIALS NT107 0103 2 DIMEScript User Guide 13 15 15 16 18 20 20 20 26 DIMEScript User Guide 6 1 Hardware Confidence Script DESIGNING WITH THE DIMESCRIPT 7 1 Design Process 7 1 1 Use of Data Areas and Variables 7 1 2 Use of Subroutines TROUBLESHOOTING 8 1 Debug Techniques 8 2 Common Questions 8 3 Technical Support Contact APPENDICES 9 1 Listing of dimecontrol c REVISION HISTORY 10 1 Details of Changes 30 32 34 34 36 38 38 38 40 42 44 46 NT107 0103 2 DIMEScript User Guide Preface In this section e About this User Guide e User Guide Contents e References e Abbreviations NT107 0103 2 1 DIMEScript User Guide 2 NT107 0103 2 DIMEScript User Guide 1 1 About User s Guide This User Guide is intended to provide detailed information on installing and using the DIMEScript software product 1 2 Navigating this User Guide There are various entry points to the information in this user guide depending on what you want to know first you may wish to start reading in different places Two suggested paths are shown below The red provides a hands on approach and is ideal for those who prefer to get the hardware up and running quickly and then learn about it as they go along 0 0
17. he Licensed Materials are Copyrighted Accordingly you may either make one copy of the Licensed Materials for backup and or archival purposes or copy the Licensed Materials to another medium and keep the original Licensed Materials for backup and or archival purposes Additionally if the package contains multiple versions of the Licensed Materials then you may only use the Licensed Materials in one version on a single computer In no event may you use two copies of the Licensed Materials at the same time 4 Warranty Nallatech Ltd warrants the media to be free from defects in material and workmanship and that the software will substantially conform to the related documentation for a period of ninety 90 days after the date of your purchase Nallatech Ltd does not warrant that the Licensed Materials will be free from error or will meet your specific requirements 5 Limitations Nallatech Ltd makes no warranty or condition either expressed or implied including but not limited to any implied warranties of merchantability and fitness for a particular purpose regarding the Licensed Materials Neither Nallatech Ltd nor any applicable Licenser will be liable for any incidental or consequential damages including but not limited to lost profits 6 Export Control The Software is subject to the export control laws of the United States and of the United Kingdom The Software may not be shipped transferred or re exported directly or indirectly into
18. ime PRICING All prices shown on the company s price list or on quotations offered by them are based upon the acceptance of these conditions Any variation of these conditions requested by the buyer could result in changes in the offered pricing or refusal to supply All quoted pricing is in Pounds Sterling and is exclusive of Value Added Tax VAT and delivery In addition to the invoiced value the buyer is liable for all import duty as may be applicable in the buyer s location If there is any documentation required for import formalities whether or not for the purposes of duty assessment the buyer shall make this clear at the time of order Quotations are made by Nallatech upon the customer s request but there is no obligation for either party until Nallatech accepts the customer s order Nallatech reserves the right to increase the price of goods agreed to be sold in proportion to any increase of costs to Nallatech between the date of acceptance of the order and the date of delivery or where the increase is due to any act or default of the customer including the cancellation or rescheduling by the customer of part of any order Nallatech reserves the right without prejudice to any other remedy to cancel any uncompleted order or to suspend delivery in the event of any of the customer s commitment with Nallatech not being met DELIVERY All delivery times offered by the company are to be treated as best estimates and no penalty
19. ins of the Ballynuey and Ballynuey II cards readtalk endpoint address size Dn lt offset gt lt columns gt Read data from the card via the DIMETalk protocol size words are read from endpoint endpoint address address If a data area is specified then data is stored in this area at the optional offset If no data area is specified data is printed to screen in specified number of columns random Dn size Insert random data into the specified data area save Dn filename aln columns lt size gt Save the specified data area to a file a indicates Append to file n indicates New file Prints out in columns If optional size is not given then all data area is saved saveb Dn filename lt offset gt lt size gt Save the data area to a binary file Optionally part of the data area at a given offset may be saved setdirio Dni lt data gt Sets the direction of the VO pins on a Ballynuey or Ballynuey II sysreset eld Enables or disables the system reset pin If no parameter is given pulses pin for 100ns silent yIn Disables or enables all output from dimescript including error messages If no parameter is given then assumed to be y setvar variable value Dimescript has up to 256 variables indicated in the code as 0 255 Where these are encountered they are replaced with a fixed value This command allows the user to specify the value For example setvar 10 12 l
20. ion 4 DIMEScript Overview NT107 0103 2 3 DIMEScript User Guide Designing Tutorials with the Troubles shooting Getting Software Installation Appendices Started Overview Description For a full description of the DIMEScript product start reading in Section 5 Software Description Designing Trouble Started Overview Description Tutorials ll shooting Getting Software Installation Appendices For some practical advice on the DIMEScript some worked examples are described through a set of tutorial examples Read Section 6 Tutorials Designing Trouble Started Overview Description Bul shooting Getting Software Installation Appendices If you are having problems with any aspect of the DIMEScript Section 7 Designing with the DIMEScript may provide the answer as it covers design processes and advanced topics Designing Tutorials with the FUE shooting Getting Software Installation Appendices Started Overview Description If your are having problems Section 8 Troubleshooting should be consulted for possible solutions Designing Tutorials with the meud shooting Getting Software Installation Appendices Started Overview Description For other useful information please consult Section 9 Appendices 1 3 References e NT301 0001 DIME Module Standard Level 0 Nallatech Ltd e NT301 0002 DIME Module Standard Video processing Level 1 implementa
21. luded in the final link command for the specific application for automatic loading The file itself should also reside either in lib or usr lib so the runtime linker can find it Alternatively the dl library can be used dynamic link For further information type man dlopen 26 NT107 0103 2 DIMEScript User Guide 5 6 3 Windows Specific A lib file has been provided in lib for linking with MS Visual C V6 0 or above called dimescript lib A lib file has been provided in lib for linking with Borland C Builder called dimescriptbcc lib For dynamic loading see LoadLibrary function call in Microsoft Win32 Help system NT107 0103 2 27 DIMEScript User Guide In this section e Hardware Confidence Script Tutorials NT107 0103 2 DIMEScript User Guide NT107 0103 2 29 DIMEScript User Guide 6 1 Hardware Confidence Script This script is provided in the distribution section of the DIMEScript directory structure It opens a card loads a bitstream into the onboard device then tests the PCI transfer function to and from the card The following is the ballynuey v800 dsc version All the other versions are substantially identical with only the name of the bitstream altering In this listing text in bold italic are comments on the functionality of the code Ballynuey v800 dsc Opencard Opens the card Printconfig Prints the card configuration on screen print Loading ping design sysreset e Enable
22. n commands 5 2 Use of Variables The interpreter handles up to 256 variables indicated in the source code as 0 to 96255 These can be set and used For example setvar 0 12 led 0 would set leds to value 12 Any loop variable can be accessed by putting x in the source code For example 0 is the outer loop variable thus loop 10 led 0 endloop would progressively set leds to 0 1 2 3 4 5 6 7 8 9 Either type of variable loop or builtin can also be incorporated into simple functions using the operators multiply divide subtract add 96 modulus amp logical and logical or For example setvar 0 Ox4f led 990 amp 0x3 Would set the leds to 0x3 Loop 10 led 10 5 Would progressively set leds to 5 6 7 etc 5 3 Command Reference The following commands are available in the DIMEScript Language base dlh Sets the base for output routines d decimal h hexadecimal backward lt numlines gt Jump backward in current file by lt numlines gt 20 NT107 0103 2 DIMEScript User Guide compare lt size gt Dn Dn Compare the contents of one data area with another Comparison is for lt size gt words channel lt channelnumber gt All data transfers to and from the board will be via this channel By default all data transfers are to and from channel 0 N B This is a future enhancement and is not implemented at FUSE V1 0 call lt scriptfilename gt Call another script file
23. ne NULL if argv 1 q error routine NULL break else strcpy filename argv argv 2 filename 0 2 2 print message Usage dimecontrol lt filename gt q s c b lt n gt n q Only display error messages n gg Silent n return 1 if filename 0 Console mode int result PRINTOUT Entering Dimescript Console help lt command gt for quit to finish n n result 0 while result PRINTOUT Dimescript gt fgets message 500 stdin PRINTOUT n result ipt_memory amp handle message print_routine error_routine NT107 0103 2 DIMEScript User Guide if result 2 result 0 else File mode sprintf message Performing script commands from s n filename PRINTOUT message result DIME script file amp handle filename print routine error routine return result NT107 0103 2 43 DIMEScript User Guide In this section e Details the Document Changes Revision History NT107 0103 2 DIMEScript User Guide NT107 0103 2 45 DIMEScript User Guide 10 1 Details of Changes Date Ref Details of Change 27 09 2001 Initial Revision for Internal Review 46 Table 1 Revision Details NT107 0103 2 Standard Terms and Conditions GENERAL These Terms and Conditions shall apply to all contracts for goods sold or work done by Nallatech Limited hereinafter
24. or Linux to execute dimescripts The first accepts a filename pointing to a file containing the script commands to execute DWORD DIME script file void handle const char scriptfile int PrintCallback const char int ErrorCallback const char The second accepts a pointer to a memory area containing the script commands to execute DWORD DIME script memory void handle const char script int PrintCallback const char int ErrorCallback const char In both cases the PrintCallback and ErrorCallback parameters should either point to a routine capable of accepting strings for output to the user or NULL if this is not required 5 5 Dimecontrol Application Usage This is a simple application that calls the above functions from the command line Usage Dimecontrol q qq filename q display only error messages qq display nothing If a filename is not specified then a commandline prompt is displayed and the user is permitted to type dimescript commands directly for immediate execution 5 6 Software Interfacing Considerations 5 6 1 General An include file dimescript h is provided in include directory which should be used for function prototypes As the product is provided as a runtime library DLL then it can either be linked into the user application or loaded at runtime 5 6 2 Linux Specific The Linux dimescript so is a standard ELF shared library As such it needs to be inc
25. or such other addresses as that party may from time to time notify in writing and shall be deemed to have been served if sent by post 48 hours after posting Licensing Agreement Nallatech Ltd software is licensed for use by end users under the following conditions By installing the software you agree to be bound by the terms of this license If you do not agree with the terms of this license do not install the Software and promptly return it to the place where you obtained it 1 Licence Nallatech Ltd grants you a licence to use the Software programs and documentation in this package Licensed materials if you have a single license on only one computer at a time or by only one user at a time if you have acquired multiple licenses the Software may be used on either stand alone computers or on computer networks by a number of simultaneous users equal to or less than the number of licenses that you have acquired and if you maintain the confidentiality of the Software and documentation at all times 2 Restrictions This software contains trade secrets in its human perceivable form and to protect them except as permitted by applicable law you may not reverse engineer disassemble or otherwise reduce the software to any human perceivable form You may not modify translate rent lease loan or create derivative works based upon the software or part thereof without a specific run time licence from Nallatech Ltd 3 Copyright T
26. or which they were sold Features not documented in the user manual or a written offer of the company will not be supported Interfacing with other products other than those that are pre approved by the company as compatible will not be supported If the development tools and system hardware is demonstrably working no support can be given with application level problems WARRANTY The company offers as part of a purchase contract 12 months warranty against parts and defective workmanship of hardware elements of a system The basis of this warranty is that the fault be discussed with the companies technical support staff before any return is made If it is agreed that a return for repair is necessary then the faulty item and any other component of the system as requested by those staff shall be returned carriage paid to the company Insurance terms as discussed in the INSURANCE section will apply Returned goods will not be accepted by the company unless this has been expressly authorised After warranty repair goods will be returned to the buyer carriage paid by the company using their preferred method Faults incurred by abuse of the product as defined by the company are not covered by the warranty Attempted repair or alteration of the goods as supplied by the company by another party immediately invalidates the warranty offered The said warranty is contingent upon the proper use of the goods by the customer and does not cover any
27. ossess the goods as aforesaid and for this purpose admit or procure the admission of Nallatech or its employees and agents to the premises in which the goods are situated INTELLECTUAL PROPERTY The buyer agrees to preserve the Intellectual Property Rights IPR of the company at all times and that no contract for supply of goods involves loss of IPR by the company unless expressly offered as part of the contract by the company GOVERNING LAW This agreement and performance of both parties shall be governed by Scottish law Any disputes under any contract entered into by the company shall be settled in a court if the company s choice operating under Scottish law and the buyer agrees to attend any such proceedings No action can be brought arising out of any contract more than 12 months after the completion of the contract INDEMNITY The buyer shall indemnify the company against all claims made against the company by a third party in respect of the goods supplied by the company SEVERABILITY 48 If any part of these terms and conditions is found to be illegal void or unenforceable for any reason then such clause or section shall be severable from the remaining clauses and sections of these terms and conditions which shall remain in force NOTICES Any notice to be given hereunder shall be in writing and shall be deemed to have been duly given if sent or delivered to the party concerned at its address specified on the invoice
28. referred to as the company or Nallatech and purchased by any customer hereinafter referred to as the customer Nallatech Limited trading in the style Nallatech the company submits all quotations and price lists and accepts all orders subject to the following conditions of contract which apply to all contracts for goods supplied or work done by them or their employees to the exclusion of all other representations conditions or warranties express or implied The buyer agrees to execute and return any license agreements as may be required by the company in order to authorise the use of those licensable items If the licensable item is to be resold this condition shall be enforced by the re seller on the end customer Each order received by the company will be deemed to form a separate contract to which these conditions apply and any waiver or any act of non enforcement or variation of these terms or part thereof shall not bind or prejudice the company in relation to any other contract The company reserves the right to re issue its price list at any time and to refuse to accept orders at a price other than at the price stated on the price list in force at the time of order The company reserves the right to vary the specification or withdraw from the offer any of its products without prior warning The company reserves the right to refuse to accept any contract that is deemed to be contrary to the companies policies in force at the t
29. s In addition a command line utility is provided that allows the user to interactively access these features 4 2 Overall Functional Diagram This diagram shows the DIMEScript shared library This can be used either by the FUSE Environment the dimecontrol application or any user application The two entries to the DIMEScript library are for scripts contained in files and scripts contained in a local memory buffer See section 5 FUSE Environment User application Dimecontrol application DimeScript Shared Library DWORD DIME script file DWORD DIME script memory NT107 0103 2 15 DIMEScript User Guide 4 3 Available Functions The following functions are available in DIMEScript For more details on each function see section 5 Syntax Key Dn data area DO Df lt gt User supplied parameter optional parameter A B parameter A or parameter B exclusive or Dimescript Commands base d h backward lt numlines gt compare size Dn Dn channel lt channelnumber gt call lt scriptfilename gt clockset clock frequency config module device lt bitfilename gt callext lt libname gt lt routinename gt closecard dsize Dn lt size gt delay lt milliseconds gt endloop now eprint statements else endif fpgareset e d fprint filename ain statements forward lt numlines gt goto lt linenumber gt help lt command gt if Dn amp 2 value
30. s are found to be damaged after unpacking the company must be informed immediately Under no circumstances should the damaged goods be returned unless expressly authorised by the company Ifthe damage is not reported within 48 hours of receipt the insurers of the company shall bear no liability Any returns made to the company for any reason at any time shall be packaged in the original packaging or its direct equivalent and must be adequately insured by the buyer Any equipment sent to the company for any purpose including but not limited to equipment originally supplied by the company must be adequately insured by the buyer while on the premises of the company PAYMENT Nallatech Ltd terms of payment are 30 days net Any charges incurred in making the payment either currency conversion or otherwise shall be paid by the buyer The company reserves the right to charge interest at a rate of 2 above the base rate of the Bank of Scotland PLC on any overdue accounts The interest will be charged on any outstanding amount from said due date of payment until payment is made in full such interest will accrue on a daily basis TECHNICAL SUPPORT The company offers a dedicated technical support via telephone and an email address It will also accept faxed support queries Technical support will be given free of charge for 90 days from the date of invoice for queries regarding the use of the products in the System configuration f
31. service pack you are using For example Xilinx Foundation or Alliance 3 1i service pack 8 Avenues for support are e EMAIL WWW Support nallatech com www nallatech com and then click on support NT107 0103 2 DIMEScript User Guide NT107 0103 2 39 DIMEScript User Guide In this section e Listing of dimecontrol c Appendices NT107 0103 2 DIMEScript User Guide NT107 0103 2 41 DIMEScript User Guide 9 1 include include include include include int prin return define define int main cha cha int Listing of dimecontrol c lt stdio h gt lt stdarg h gt lt dimesdl h gt lt dimescript h gt stdio h t message const char message printf message PRINTOUT a if print routine print routine a ERROROUT a if error routine error routine a int argc char argv r filename MAX PATH 0 r bustype 4 PCI 0 cardnumber 1 DWORD result DIME HANDLE handle NULL int int pri err whi if type syntax DIME scr 42 print routine const char error routine const char char message 500 nt routine amp print message or routine amp print message le argc gt 0 if targv 0 switch targv 0 case c argc strncpy bustype argv 3 bustype 3 0 break case b argc sscanf argv d amp cardnumber break case q print_routi
32. taining executables only Example shared library for callext function Include files Library files Bitfiles for examples Documentation Adobe Acrobat use xpdf 2 2 Software amp Hardware Requirements DIMEScript is an interpreted scripting language for control and operation of Nallatech DIME and DIME Il boards modules DIMEScript requires that the relevant Nallatech board software be installed for the board s to be used DIMEScript runs under the following operating systems Microsoft Windows 2000 Microsoft Windows Millennium Edition Microsoft Windows NT Service Pack 4 Microsoft Windows 98 Linux kernel 2 2 x 2 4 x Tested under RedHat Linux 7 1 6 2 NT107 0103 2 DIMEScript User Guide 2 3 Software Installation Guide Windows The software is installed as part of the general FUSE installation 2 4 Software Installation Guide Linux The software is installed as part of the general FUSE installation NT107 0103 2 DIMEScript User Guide Getting Started In this section e Software Confidence Test NT107 0103 2 9 DIMEScript User Guide 10 NT107 0103 2 DIMEScript User Guide 3 1 Software Confidence Check 3 1 1 Basic Software Check A simple check that DIMEScript has been successfully loaded is included in the distribution area Change directory to that area and type DOS dimescript confidence dsc Linux gt dimescript confidence dsc The following should be displayed on the
33. the reset to the main card fpgareset e Enable the reset to the onboard FPGA clockset 0 40000 Set all clocks to 40MHz 40000 KHz config 0 0 bitfiles nueyping2_V800 bit Load first device with bitstream pcireset Reset the PCI interface fpgareset d Disable the reset to the onboard FPGA sysreset d Disable the reset to the main card printconfig use variable 0 to store size of transfer test Note this is used in viwrite and viread as well setvar 0 64 Set up local variable as 64 print Testing card transferring 0 values Main testing loop loop 100 randomize input memory random D3 0 Fill data area D3 with random values call viwrite dsc Call external function viwrite dsc call viread dsc Call external function viread dsc compare one with other quiet y compare D3 D1 0 Compare data area D3 with DO quiet n endloop print Board testing completed successfully closecard Close the card Viwrite dsc writing to card via vidime protocol writeaddr 1 writedata 1 0 writeaddr 0 writedata 1 1 writedata 0 D3 Write 64 words from D3 to open card 30 NT107 0103 2 DIMEScript User Guide Viread dsc reading from card via vidime protocol writeaddr 1 writedata 1 0 writeaddr 0 writedata 1 3 readdata 0 D1 Read 64 words from card to D1 writeaddr 0 writedata 1 0 NT107 0103 2 31 DIMEScript User Guide Designing with the DIMEScript In this section e Design Processes e Advanced Topics 32 NT1
34. tion Nallatech Ltd e NT102 0045 Ballynuey Il User s Guide Nallatech Ltd 1 4 Abbreviations e DIME DSP and Image Processing Modules for Enhanced FPGAs e FPGA Field Programmable Gate Array e DLL Dynamically Linked Library e FIFO First In First Out e MDF Module Definition File e GUI Graphical User Interface 4 NT107 0103 2 DIMEScript User Guide Installation Guide In this section e Product Items Checklist e Software amp Hardware Requirements e Software Installation Guide NT107 0103 2 5 DIMEScript User Guide 6 NT107 0103 2 2 1 Product Items Checklist DIMEScript is a pure software product DIMEScript User Guide It comes on a delivery CD marked DIMEScript Vx x where x x is the version of DIMEScript supplied DIMEScript is distributed as a standard windows DLL or a shared library for Linux In addition a console application is provided The software is structured on the CD under subdirectory dimecontrol as follows microsoft linux dimecontrol distribution exampledll include lib bitfiles doc dimecontrol distribution exampledll include lib bitfiles doc Directory Contents Console application using dimescript library MSVC Area containing executables only Example shared library for callext function Include files Library files Bitfiles for examples Documentation Word and Adobe Acrobat Console application using dimescript library Area con
35. will be honoured by the company exactly No other warranty is offered by the company on these products Return of faulty equipment after the warranty period has expired the company may at its discretion make a quotation for repair of the equipment or declare that the equipment is beyond repair PASSING OF RISK AND TITLE The passing of risk for any supply made by the company shall occur at the time of delivery The title however shall not pass to the buyer until payment has been received in full by the company And no other sums whatever shall be due from the customer to Nallatech If the customer who shall in such case act on his own account and not as agent for Nallatech shall sell the goods prior to making payment in full for them the beneficial entitlement of Nallatech therein shall attach to the proceeds of such sale or to the claim for such proceeds The customer shall store any goods owned by Nallatech in such a way that they are clearly identifiable as Nallatech s property and shall maintain records of them identifying them as Nallatech s property The customer will allow Nallatech to inspect these records and the goods themselves upon request In the event of failure by the customer to pay any part of the price of the goods in addition to any other remedies available to Nallatech under these terms and conditions or otherwise Nallatech shall be entitled to repossess the goods The customer will assist and allow Nallatech to rep