Home
BLooKLED transilluminator
Contents
1. Golden Angle Optimized for use with the nucleic acid and protein fluorescent dyes Blue light source good for 30 000 hours e No risk of UV damage for high quality work experience Smart power saving function Automatic power shut off option at 5 minutes Gel cutting knife Cut out the target from the gel for further experiment P 01 AEHFORTFRA RN IAE JH AMIZAU Specifications Unit dimensions W x Lx H Gel viewing dimensions W x L x H Weight g Emission maxima nm Store temperature Operating temperature Auto shut off min Filter type Amber filter ideal for Novel Juice Novel Green Novel Green Plus OnePCR OnePCR HiFi OnePCR HotStar OnePCR Plus OneMark B OneMARK 100 Nimble Juice Nimble Juice RTYPE Contents A Power Cord Used to connect the BLooK port with the power socket B BLooK LED transilluminator C Gel Cutting Knife Cut out the target from the gel for further experiment D Replacement Blade Used as the new blade P 02 f BLooK LED transilluminator Light source The light source is located below and projects upward from the bottom Please first lower the amber filter in position when in use for preventing the strong light from harming the eyes Amber filter The upper panel is the amber filter used to observe the gel upon being lowe
2. AEBREDIZI_TFEKKKAN IZE NAA MES BLOOK LED transilluminator GeneDireX AEHEDITHKRRA JAE NAAM TSL BLOOK LED transilluminator Catalog number BK001 Serial number BK27888001 Description BLooK is a remarkable blue light LED transilluminator for the detection of nucleic acids or protein under non UV conditions The wavelength of the special blue LED lights is 470 nm fig 1 hence no damage to your nucleic acids or protein Also since UV is not used there is no need for any special personal eye or skin protection The blue LED lights are arranged under the viewing area 200 x 120 mm An amber filter on hinges is lowered into position once your gel is mounted The stained gel is now ready for viewing This instrument has a specially designed ergonomic 4 angle so users can easily sit on a chair to see the experiment results BLooK is designed to view the gel after running electrophoresis on the gel stained with the Novel Juice Novel Green Novel Green Plus Nimble Juice or Nimble Juice RTYPE Further it is perfectly designed for OnePCR OnePCR HiFi OnePCR HotStar OnePCR Plus OneMARK B and OneMARK 100 which contains the fluorescent stain compatible with the blue light wavelength However BLooK is not suitable for ethidium bromide 380 420 460 500 540 580 Wavelength nm Fig 1 Emission spectrum for the BLooK LED transilluminator Features e Ergonomic fusion Patented 4 ergonomic viewing angle
3. stam product which is indicated by the symbol to the left radiation when Class 2 LED product open do not stare into the beam Safety Information The BLooK LED transilluminator is an electrical device Never touch the power cord or outlet with wet hands Do not use this device in damp areas or while standing on damp floors Do not attempt to open the BLooK LED transilluminator The BLooK LED transilluminator should be used with the supplied power cord Only these power cords should be used to power the device Attach the power cord to the BLooK LED transilluminator at the back of the device Plug the other end of the power cord into a properly grounded electrical outlet ensuring the correct plug adaptor is attached Always disconnect the BLooK LED transilluminator from the electrical outlet before cleaning the device The BLooK LED transilluminator does not produce UV light however it does utilize an intense blue light for viewing gels It should be noted that published literature has identified blue light as a possible risk factor for macular degeneration however no clinical studies have been published Therefore the BLooK LED transilluminator amber filter unit provided with this device should be used to protect your eyes while viewing gels The amber filter unit is NOT a safety screen for UV emission and will NOT protect your eyes when viewing gels on UV transilluminators After viewing and documenting the gel or sample a
4. Do not use aggressive cleaning detergents or solvents After use of the transilluminator we recommend to wipe off the frame and the filter glass with a damp cloth Take care that the cloth is not soaked with scrubbing or corrosive detergents as this could damage the filter glass We suggest using alcohol glass cleaners or similar mild detergents Pay attention to wearing appropriate gloves when cleaning areas as the filter plate of the transilluminator switches protection shield which may have been in contact with carcinogenic or toxic reagents The protection shield is made of tempered glass and must only be cleaned with a damp cloth Method of Replacing with the New Blade When replacing with the new blade unscrew the black handling part of the knife counterclockwise from the blue part Push out the blue part s blade holding section Remove the old blade and open the SPARE BLADE for taking out the new replacement blade Insert it into the X shaped blade insertion hole Restore the blue connector back into the original position and then screw tight the blue part with the black handling part clockwise Caution The blade is quite sharp Please act with caution to avoid cuts Replacement of Spare Parts Only original spare parts are allowed Servicing Please contact your local dealer The BLooK LED transilluminator is warranted against defects in materials and workmanship for 1 year If any defects occur in the instrument or acces
5. lways press the unit off Warranty GeneDireX warrants that BLooK LED transilluminator will be free from defects in material and workmanship for a period of one year from date of purchase If a defect is present GeneDireX will at its option repair replace or refund the purchase price of this product at no charge to you provided it is returned during the warranty period This warranty does not apply if the product has been damaged by accident abuse misuse or misapplication or from ordinary wear and tear This warranty shall be limited to the replacement of defective products It is expressly agreed that this warranty will be in lieu of all warranties of fitness and in lieu of the warranty of merchantability P 08 Made in TAIWAN CHINA Patent CN203115668U TAIWAN Patent M449283
6. nator complies with the European Community Safety requirements A CE Marking is a European marking of conformity that indicates a product complies with the essential requirements of the applicable European laws or directives with respect to safety health and environment and consumer protection Generally this conformity to the applicable directives is done through self declaration The CE Marking is required on products in the countries of the European Economic Area EEA to facilitate trade among the member countries The manufacturer or their authorized representative established in the EEA is responsible for affixing the CE Marking to their product The CE Marking provides a means for a manufacturer to demonstrate that a product complies with a common set of laws required by all of the countries in the EEA to allow free movement of trade within the EEA countries Caution Caution risk of danger Consult the User Guide for further safety information Do not dispose of this product in unsorted municipal waste Caution To minimize negative environmental impact from disposal of electronic waste do not dispose of electronic waste in unsorted municipal waste Follow local municipal waste ordinances for proper disposal provision and contact customer service for information about responsible disposal options P 07 AER O R FERRA IZJENTAKIET Caution The BLooK LED transilluminator is classified asa Class 2 LED LED radiation
7. red in position Power inlet is used for connecting the power cord Ventilation holes are located on ihe same side 4 and enable the heat which is generated when power is on to be displaced ON OFF button is used for switching on and off the power Dented holder Along dented holder which is located close to the operator is used to store the gel cutting knife Operating 1 Place the BLooK LED transilluminator on a level bench with enough space around the unit for allowing air circulation and preventing overheating P 03 P 04 AEREDIZITEKKRAN VALE VARA AL 2 Connect the power cord and the socket 3 Place the gel on the transparent glass support area Note It is recommended that gloves be worn to prevent skin contact with gel and staining agents 4 Close the amber lid above the gel 5 Press the ON OFF to ON mode 6 Now the fluorescent samples can be viewed or cut LN EA Note For cutting fluorescent samples out of the gel please lift the lid to access the gel 7 When finished turn the transilluminator off 8 Clean the transilluminator filter and surface by wiping with a wet not scratching cloth AEB DIFEKKRA JAE NZA MTS Troubleshooting Refer to the table below to troubleshoot problems that you may encounter when viewing with the BLooK LED transilluminator Low sensitivity Wavelength may not be right Check the excitation and emission wavelengths of the fluo
8. rescence dye Automatic shut off Automatic power off system Press the power button again to re turn on the light High background Low sample concentration Check the concentration of sample suboptimal or no image Related Ordering Information Cat No Description Size LD003 0500 Novel Green Plus 500 ul MB203 0100 OnePCR 100 Reactions MB205 0100 OnePCR HiFi 100 Reactions MB206 0100 OnePCR HotStar 100 Reactions MB207 0100 OnePCR Plus 100 Reactions DM101 0100 OneMARK 100 600 ul DM110 0100 OneMARK B 600 ul NJ001 0010 Nimble Juice 10 ml 100x NJ002 0500 Nimble Juice RTYPE 500 mL Note Please read the installation instruction carefully before installing the BLooK LED transilluminator This instrument is intended for clinical and research laboratory use and it must be operated only by specialized personnel aware of the potential risks associated with the chemical and biological agents normally used with this unit This instrument is meant for use only by specialized personnel that know the health risks associated with blue light radiation and with reagents that are normally used with this instrument It is designed to shield only the person working in front of the system and to observe the gel fluorescence emission clearly P 05 NEBBORT FERRAN JAE NZA RAWAL Maintenance and Repair Cleaning and Maintenance The transilluminator should be damply wiped off with a soft cotton cloth The cloth should not be too wet
9. sories during this warrant period GeneDireX will repair or replace the defective parts at its discretion without charge The following defects however are specifically excluded 1 Defects caused by improper operation Repair or modification done by anyone other than GeneDireX or an authorized agent Damage caused by substituting alternative parts Use of fittings or spare parts supplied by anyone other than GeneDireX Damage caused by accident or misuse Damage caused by disaster Corrosion caused by improper solvent or sample For any inquiry or request for repair service contact your local GeneDireX office Inform the model and serial number of your instrument NDA W PO P 06 AER FORF EER KA IZE NAA MTS REGULATORY NOTICE IMPORTANT This GeneDireX instrument is designed and certified to meet safety standards Certified products are safe to use when operated in accordance with the instruction manual This instrument should not be modified or altered in any way Alteration of this instrument will 1 Void the manufacturer s warranty 2 Void the safety and EMC certification 3 Create a potential safety hazard GeneDireX is not responsible for any injury or damage caused by the use of this instrument for purposes other than those for which it is intended or by modifications of the instrument not performed by GeneDireX or an authorized agent Appendix Explanation of Symbols and Warnings BLooK LED transillumi