Installation & User Manual V2.04

image

Contents

1. Setting the GSD controller address Phase 1 Setting up the GSD Controller Stepes OOOO a Install the main GSD Controller and power up Default the controller immediately via the dip switch settings See instructions on page 11 Important Once powered up and the controller has completed the default the process reset the dip switches to the correct address positions See instructions on page 11 Connect the PC lead to the Contoller and configure the PC Comms A lf using a Serial to USB converter Follow USB converter instructions B Establish the Com Port no Follow instructions on the CD provided to install the GSD PC application To download the latest drivers enter the following link in your web browser http www globalsecurity ie download GSDW in Access en US zip Open the application with the PC connected to the controller Log in to the application as the Engineer not the administrator with the password 6666 Go to the settings tab and set the Com port number for the Controller as established above The Controller icon will change colour to show that the Controller is on ine Open the Doors tab in the main menu to add the required number of new doors to be part of this network 1 door will already be added by default Click on the button to add new doors to remove doors M ake sure all doors are Enabled and then click Save Open the Settings Tab and do a Full Download to the
2. NO Inputs 3V Lithium dl J Fire Alarm Panel NOTE Common OV from the Fire Alarm Panel and the OV from the Controller to avoid any ground loop issues Direct Connect All Dip Switches OFF W hen the fire alarm is activated ie OV removed from IP3 the local door will be opened L Network Diagrams 12V RS485 Converter A a EEECoC T Controller 1 S 42V 4 E oV 2 Connect using RS232 RS485 g l 38 cable to serial port on PC Daisy Chain Set Baud Rate to 19200 ert Paice PC Network Connections when using more ON B than one GSD Controller Daisy chain the PC network A B OV to each controller Set an individual address for each controller between 1 amp 3 using the dip switches see below Controller 2 U 9 Controller 1 Controller 2 i 19911q Od Controller 3 Address 1 Set SW 1 ON Address 2 Set SW2 ON Address 3 Set SW 3 ON Network Diagrams Direct Connect All OFF Address 1 Set SW1 ON Address 2 Set SW2 ON Note Address 3 Set SW 3 ON only To restore the factory default setting Set ALL Dip Swithces 1 2 3 amp 4 to the ON position and then power up the GSD Controller Example All Dip Swithces are set to the ON position Note Factory Default settings will be restored after powering up the controller with All dip swithces ON The dip Switchess should then be set to the controller address as shown above in section
3. networks and Door Controls in the same building on a different network becoming part of this new network Note For Wired 485 Door Controls right click on the Controller on the right hand side of the application and select Manually Assign Address from the drop down menu Once all new Door Controls are found by the Controller they will all beep with the number of the next available address door position on the Controller e g if door 2 is the next available address then all Door Controls will beep at the same time with 2 beeps This is basically saying that any door can be assigned to this address it s up to the installer to decide which one Also you will notice that the Key back light of the keypad Door Controls will be illuminated with the next available address as well i e Key 2 will be illuminated for this example Go to the Door control that you want to make door 2 on the network system it should be beeping 2 times Press any key on this keypad and the system will automatically assign this door control to door 2 location on the system Present a card if the Door Control is Prox Only Note All other Door Controls will now start beeping with the next available address i e 3 beeps in this instance and so on every time you enrol a new Door Control The Key back light will also correspond to each address as the system fills up Phase 3 Enrolling Door Controls Step Description S La a A Once all Doo
4. Controller this gives the Controller a clean set of instructions before beginning to enrol doors onto the network This will take approximately 1 minute ARNING A New Network should only be created on first installation Creating a new network will overwrite any existing network information and any enrolled Door Controls will be un enrolled All Door Controls will have to be defaulted and re enrolled on the new network that has just been created A new network is now ready to be created Go to the Controllers tab and Click on the Create a New Network button Click Yes on the Hit yes if you want to proceed pop up Note The red LED on the Controller PCB will remain ON during the process It will take about 20 60 seconds to complete The red LED will Start to flash again when the Network is created Phase 3 Enrolling Door Controls Step Description O E All Door Controls should be installed at this point and powered up All Door Controls must be defaulted before joining a network Note Door Controls will be shipped with their factory default settings Enter Engineer mode on each Keypad Door Control in the following way Press X followed by 6666 Enter 55 to default Press the tick to confirm the keypad will now go through the process of defaulting itself W hen this process has complete hit the X button to leave engineer mode and to put the keypad control in the Scan Mode the Red Led on the Door Control
5. Other products from GSD Stand alone products global security devices GSO also offers fully functional standalone door controls for less complex door management This attractive design with modem aesthetics will complement any building 65D Digital Keypad GSO Proximity Switch OSD Biometric switth Acess control Door monitoring Manager user fire and intruder alarm interface Backlighting Tamper resistant 5 Amp relays indoor or outdoor use Robust polycarbonate housing with stainless steel keys Multi format RRO reader eei Installation Instructions ED PIN ACCeSS f FngerPrnt T Installation Diagrams ED ACCESS IP Rating P67 IP67 IP67 P65 No of doors controlled 2 door 1 door 1 door 1 door Mounts onto a standard electrical Be i back bax Power 12v to 24v 12v to 24v 12 to 2A 12v OC only re ee ee cee Wiring Diagrams ED System Overview iy Network Diagrams ED Operating Instructions Ry Fingerprint Enrollment FED global security devices Wi Plus Controller Technical Specs GSD Wi Plus Controller Current consumption with load max W 135mm D 46mm H 200mm Technical Specs Wi Plus Door Controls Dimensions Flush Mount Features 16 16 16 Doors controlled 10 Us Reporting Facility Yes Challenge Facility Yes Logging Unlimited Input Output M apping CCTV amp Lift control Supports Wireless amp RS485 Networks A
6. instead of All Day Every day UserGroups are created by combining pairs of DoorGroups with Timezones Each UserGroup can have up to 6 pairs of DoorGroups and Timezones Select DoorGroups and Timezones from the drop down menus to add to the current UserGroup Timezones are the periods of time for each day of the week that access will be granted Select times and tick the days of the week this time is valid 4 time periods can be created for each timezone Select Holiday Access to grant access for holiday periods Double click on the Holiday Access to add days to the holiday periods Use the calender to select these days DoorGroups are created by grouping doors together e g all the entry and exit doors could be grouped together as Peremiter Doors Select a Door from the All availble Doors window and drag it to the Doors in Current Door Group to add it to the Door Group Repeat for adding each door Phase 6 Downloading Configuration Step Description O After all users access levels and door control settings have been finalised a full download to the controller should be carried out Go to the Settings tab and click on Download Configuration A pop up window will appear tracking the status of the download All settings will be downloaded to the Controller and Door Controls Enrolling User FingerPrints Step Description W Note M ake sure the USB Fingerprint reader is attached to
7. ot store the finger EL UL OA print It uses an algorithm to generate a es binary representation using sample points from the fingerprint It uses this information to then validate each users fingerprint wy Py Finger Placement Wi BIO Finger Placement Wi BIO FEJ Correct Finger Placement Incorrect Finger Placement Correct Incorrect Note Ensure that the finger is centered and Note Incorrect placement finger does not placed flat to the surface and fully covers the fully cover the sensor window sensor window The door control will not respond and the red light will not turn off if the sensor window Note Finger must remain on the sensor is not fully covered by the finger window until the door control acknowledges that the finger has been scanned by sounding a beep and turning off the red light This will take approximately 1 second
8. r Controls are enrolled onto the network go back to the Controller application and click the Secure Network button this safeguards the systems if you select another tab on the aplication this will happen automatically Enable a User by ticking the Enabled box for each User Assign a Name to the User Assign a UserGroup from the drop down menu The Usergroup will determine the access levels for this User Refer to section below on Configuring Access Levels for information on User Groups Select each Door on the application and configure individual settings such as Timed Actions Relay Times Ajar Times Door Option and Alarm Options etc Assign a Card PIN number and enrol FingerPrints for the User Refer to section FingerPrint Enrolment on page 19 Click Save to transmit these changes to the Controller IMPORTANT A timezone must be selcted in Timed Actions for one of the options Card and PIN Any Card Card or PIN or PIN only lf all of these are set to inactive then access will be denied for all cards and PINs on that Door Control Example Disabling cards fobs Enabling PIN codes only on a WI PINGProx Set the Timed Action Card or PIN to Inactive and setting the Timed Action PIN Only to All day Every Day This will grant access for PIN codes and deny access for cards and fobs To enable or disable Timed Actions at specific times select a timezone from the drop down list
9. rol in the chain Door Control Door Control 3 4 10 Note If using a single Controller RS485 Network to Controllers an RS232 cable may be used Max number of Controllers 3 Max cable length 10 meters Max Cable Length 1 4 km Controller 2 3 50 meters Controller 1 50 meters 50 meters Door Control 50 meters 4 Door Control 1 Door Control 3 50 meters 5 0 meters 50 meters Door Control 2 Note Door Controls can be installed within 50 meters of the Controller or within 50 meters of any other Door Control as each Door Control will function as a repeater Each repeater Door Control transmits data to from the Controller 5 10 41 Wiring Diagrams Wiring Diagrams with Local Door Connections Network Diagrams ED Network Diagrams for Single Controller Sounder DB9 Female Serial Cable a O PC Network Connection k uputs AO can be used for multiple Wie AG controllers See page 2 7 A sono SS 10 for wiring z BERS Use PC Direct i e COM Connect DB9 cable Connections if using j f to serial port on PC a single controller 1 ud See page 9 for wiring J Maximum cable P z length 10 meters 3 P S I Wired 485 Networ e P 12V Linear z Connections a7 Power supply 2 AC al PC Direct Connection can be used when B Q a using ONLY one GSD Controller S ye Set the Direct address to 7 ALL dip switches OFF see below Ele Ne SP Zdi vVEckh
10. the PC Select the User for fingerprint enrollment Click on the Fingerprints button Click on Enrol tick box and place finger on the enrolment reader An image of the fingerprint will appear on the screen Ensure that the image quality is good and a value of at least 90 is achieved Refer to section Finger Placement for correct finger placement and example of good quality image Repeat this process if this is not achieved on first attempt Click Save using a good quality template only Poor Quality templates can lead to false rejections later when trying to gain access L Finger Placement Wi BIO Finger Placement Wi BIO P25 Correct Finger Placement Incorrect Finger Placement Note Incorrect placement finger does not fully cover the sensor window YS coos Quality Image Note Ensure that the core of finger is ro centered on the sensor window during Enrol succeeded Q 98 v m x the enrollment process This will increase the quality of the fingerprint template AUAN Note Poor Quality image No Fingerprint y Linn core on sensor window M 6 j AN X Poor Quality Image l Enrol succeeded Q 76 Z m X This can result in poor template quality that Note Good Quality image Fingerprint core at NN 7 P f SSAIM EEUNA a a n is center of sensor window f We jJj HANS can lead to false rejection issues later when ee jj the user is trying to gain access 4 Note The System does n
11. utomatic Backup Facility Database Encryption Installation Steps Step Description i Page Install the Controller using the Installation Diagrams W ire the Controller using the W iring Diagrams 8 Install and wire each Door Control Refer to the Door Control E Manual for instructions 4 Connect the Controller to the PC using Network Diagrams 9 11 Restoring Factory Defaults Phase 1 Setting up the GSD Ccontroller 6 ee J Installation Diagrams Installation Diagrams p 1 To open front cover of GSD Controller remove screw cap using screwdriver then loosen screw 3 screw the rear enclosure to the wall as shown below 2 Remove door from unit see inset before screwing the rear enclosure to the wall To remove front cover lift tab up and unhook door 4 Re attach the front cover To re attach front cover hook door over top pip and rotate into position and push tab down to secure Use for retaining cables Note If using a single Controller an RS232 cable may be used M ax cable length 10 meters Place a120ohm Termination Resistor across A amp B onthe Controller RS485 Network to Controllers M ax number of Controllers 3 M ax Cable Length 1 4 km BS x Controller 2 3 Controller 1 RS485 Network to Door Controls Max Cable Length 1 4 km Daisy Chain Configuration Only Door Control Door Control Place a 1200hm Termination Resistor across A amp B on the last Door Cont
12. will now be in flicker mode as an indication Repeat the process for all keypad Door Controls Enter Engineer mode on each Wi Bio Door Control in the following way Enter 6666 Enter 55 to default Scan Finger to confirm the Door Control will now go through the process of defaulting itself W hen this process has complete Scan Finger again to leave engineer mode and to put the Door Control in the Scan Mode the Red Led on the Door Control will now be in flicker mode as an indication Repeat the process for all W i Bio Door Controls Enter Engineer mode on each Prox Only Door Control in the following way A Addaprogramming card to the Door Control by presenting a card twice on power up The security wing must be removed first Present this new programming card to enter Engineer mode Present the programming card again to select Default mode Present any other card once to default the Door Control W hen this process has complete the Door Control will be in the Scan M ode the Red Led on the Door Control will now be in flicker mode as an indication Phase 3 Enrolling Door Controls Step Description O S The controller is now ready to allow Door Controls to enrol onto the Network click the Allow Doors to join this Controllers Network on the Controllers tab to start the controller scanning for new doors that do not already have an address only DoorControls without an address can enrol this will avoid other