Home
RUSH Strobe 1 5x5 - User Manual
Contents
1. 0 100 individually dimmable pixels Effects orientation Standard or inverted 180 Optics and Photometric Data Light source ii 25 x 5 W cool white LEDs Color temperature ii 6000 6500 K Control and Programming OMI dojke An DMX stand alone DMA ee AN EE 4 25 or 29 Stand alone trigger options Music trig auto trig Stand alone sequences 8 pre programmed shows or random show Stand alone Memory ne 20 scenes Setting and addressing Control panel with LCD display DMX Complance USITT DMX512 1990 RUSH STROBE 1 5x5 user manual 37 Construction A Black Je een A raid NONE EOR ANNO Steel Protection ratiNg ii IP 20 Installation Location Indoor use only must be fastened to surface or structure Mounting points Integral hanging brackets side by side mounting locks Orientation einen ei Any Connections AC power mmh Neutrik PowerCon DMX data in thru 3 pin amp 5 pin locking XLR Electrical PO DOWEL an 100 240 V nominal 50 60 Hz Typical total power consumption i 148 W A A T6 3A Power consumption figures are typical not maximum Allow for 10 variation Typical power and current TOV OO A An 148 W 2 0A ZO SU HZ eeneg 146 W 1 2 A Thermal COIN ee Forced air Max
2. nena 19 DMX GAUGES SING na naeh 19 DMX Channel Modos msn een a es 20 Show mode AUTO IG ee esse 20 Manual Scuderia aa teva nia 21 Sound activation Music Md elle 21 P o ee eRe me 21 bED GiSpia Vonorace 22 EED OISPIAY e eri 22 A le 22 A A EEA EO EOM 23 FIrMWare EE 23 A ee Rn Be PE ONE TI ME RE 24 Line number or letter efec ini en 24 StObe eliecis O VE ee ee A 24 ETS CUO IG CINTIA a ee innen a 24 Maitena O relais 25 A gusiari tee et eee ee ee 25 SERVICE and Topal Sn dsd 26 Bs E 27 4 Channel Mode 27 25 channel Mode nina 30 PC KAMRE MOJO slice lille A ore ea 31 CONTO TIME TS rasa ois cess aac illa FFOUDIESNOGING ds ae SDE CIC A ON Ss taa Safety information WARNING Read the safety precautions in this manual before installing operating or servicing this product The following symbols are used to identify important safety information on the product and in this manual AAA AA Warning Warning Warning Warning Warning Safety hazard Powerful light See user Hazardous Hot surfaces Risk of severe emission Risk manual for voltage Risk and fire injury or of eye injury important of lethal or hazard death safety severe electric information shock Warning Risk Group 1 product according to EN 62471 Do not stare directly into the beam Do not view the light output with optical instruments or any device that may concentrate the beam A This lighting fixture is for professional use only
3. RUSH STROBE 1 5x5 user manual 35 Fixture does not respond to DMX control 36 Potential cause Fault in the DMX network due to connector or cable damaged or incorrect DMX addressing or potential interference from proximity to a high voltage installation Remedies Check that the fixture DMX LED is on and if not check all DMX cables and connections to ensure the integrity of the physical network Ensure that the DMX network is terminated Check that the components in the DMX network all use standard DMX polarity Ensure that the fixture is set to the correct DMX address one that matches that set on the DMX control device Check the pins on the connectors from the previous fixture in the DMX network Attempt to control the fixture with another DMX control device Move the fixture if it is being operated very close to an unshielded high voltage installation RUSH STROBE 1 5x5 user manual Specifications Physical len e oi E UE ESA 9 5 kg 20 9 lbs Dimensions WxHxD 500 x 538 x 101 mm 19 7 x 21 2 x 4 in ot O12 404 _ 79 7 30 Dynamic Effects Strobe effect Electronic regular and random pulse burst strobe effects Pre programmed effects Effect letter and number display macros Electronic dimming
4. RUSH STROBE 1 5x5 user manual 33 Control menus To access the control menus press the MENU button until the required one is shown on the display Select the required menu using the ENTER button For more information see Using the control menus on page 19 ER Option setting Explanation I HE Fixture DMX address setting 4 channel DMX mode Se UI n 29 channel DMX mode Show mode 0 random and shows 1 8 Manual setting dim Manual setting strobe No sound activation Ko Too nm mode fa eee in use time Normal display Invert display uae test counter firmware version 34 RUSH STROBE 1 5x5 user manual Troubleshooting This section describes a few common problems that may occur during operation and provides some suggestions for easy troubleshooting Potential cause Remedies No light from fixture Power supply issue Ensure that the mains or fans not working such as blown fuse supply is connected and faulty connector or supplying power to the damaged cable fixture Ensure that the fixture s power on LED is lit Check all power connections and cables The fixture does not Sound activation Ensure that the fixture is react to the beat of disabled or not working not connected to a DMX music correctly signal Tap the microphone to check that it is functioning The fixture should react when in sound activation mode Install the fixture closer to the music source
5. it is not for household use The fixture must be installed by a qualified technician The safety of the installation is the responsibility of the installer The fixture presents risks of severe injury or death due to fire hazards electric shock and falls It produces a powerful concentrated beam of light that can create a fire hazard or a risk of eye injury if the safety precautions below are not followed If you have any questions about how to install operate or service the fixture safely please contact your Martin distributor see www martin com distributors for details or call the Martin 24 hour service hotline on 45 8740 0000 or in the USA on 1 888 tech 180 RUSH STROBE 1 5x5 user manual 5 Respect all locally applicable laws codes and regulations when installing operating or servicing the fixture There are no user serviceable parts inside the fixture Do not open it Refer any service or repair operation not described in this manual to an authorized Martin service technician Do not try to carry out any such operation yourself as doing so may present a health or safety risk It may also cause damage or malfunction and it may void your product warranty Install operate and service RUSH by Martin products only as directed in their user manuals or you may create a safety hazard or cause damage that is not covered by product warranties Follow the safety precautions listed below and observe all warnings in
6. 1 Select ur and press the ENTER button The display will show the version of software installed on the fixture 2 To return to a higher level of the menu structure press the MENU button RUSH STROBE 1 5x5 user manual 23 Effects This section describes DMX controllable effects that require particular explanation See DMX protocol on page 27 for a full list of the DMX channels and values required to control the different effects Line number or letter effects Line effects 30 variable speed pre programmed effects numbers O 9 count up or countdown or letters A Z can be used in 4 and 29 channel DMX modes Strobe effects The strobe effects in 4 and 29 channel DMX modes provide instant open variable speed and sound activated strobe effects Electronic dimming Overall intensity of all pixels can be adjusted in 4 and 29 channel DMX modes Individual pixels can be dimmed in 25 and 29 channel DMX modes During individual pixel dimming pixels are controlled with reference to the numbering system shown below 24 RUSH STROBE 1 5x5 user manual Maintenance Read Safety information on page 5 before servicing the fixture Refer any service operation not described in this user manual to a qualified service technician Disconnect mains power before cleaning or servicing the fixture Service fixtures in an area where there is no risk of injury from failing parts tools or other materials Installation on
7. RUSH Software Uploader 77 P N 91611399 Ordering Information RUSH Strobe 1 5x5 in cardboard box P N 90480020 Specifications are subject to change without notice For the latest product specifications see www martin com Disposing of this product RUSH by Martin products are supplied in compliance with Directive 2002 96 EC of the European Parliament and of the Council of the European Union on WEEE Waste Electrical and Electronic Equipment as amended by Directive 2003 108 EC where applicable Help preserve the environment Ensure that this product is recycled at the end of its life Your supplier can give details of local arrangements for the disposal of RUSH by Martin products RUSH STROBE 1 5x5 user manual 39 40 RUSH STROBE 1 5x5 user manual RUSH STROBE 1 5x5 user manual 41 Rest by Martin Innovation Quality Performance
8. installations The fixture can be controlled using any DMX compliant controller It can also function without DMX control as a standalone device running one of the eight pre programmed shows with the option of sound activated scene triggering We recommend the use of haze or fog to enhance STROBE 1 5x5 effects Before using the product 1 Read Safety information on page 5 before installing powering operating or servicing the fixture 2 Unpack and ensure that there is no transportation damage before using the fixture Never attempt to operate a damaged fixture 3 If the fixture is not going to be hard wired to a mains supply attach a local power plug not supplied to the end of the supplied power cable 4 Before operating ensure that the voltage and frequency of the power supply match the power requirements of the fixture See Specifications on page 37 5 Check the Martin Professional website at www martin com for the most recent user documentation and technical information about the fixture RUSH by Martin user manual revisions are identified by the revision letter at the bottom of the inside cover 10 RUSH STROBE 1 5x5 user manual Physical installation Read Safety information on page 5 before installing the fixture This fixture may only be installed by qualified and experienced professionals The fixture is designed for indoor use only and must be used in a dry location with adequate ventilation Ensure that n
9. your RUSH by Martin dealer about a suitable maintenance schedule Use gentle pressure only when cleaning and work in a clean well lit area Do not use any product that contains solvents or abrasives as these can cause surface damage RUSH STROBE 1 5x5 user manual 25 To clean the fixture 1 Disconnect the fixture from power and allow it to cool for at least 10 minutes 2 Vacuum or gently blow away dust and loose particles from the outside of the fixture and the air vents with low pressure compressed air 3 Clean the LED lenses by wiping gently with a soft clean lint free cloth moistened with a weak detergent solution Do not rub the surface hard lift particles off with a soft repeated press Dry with a soft clean lint free cloth or low pressure compressed air Remove stuck particles with an unscented tissue or cotton swab moistened with mild glass cleaner or distilled water 4 Check that the fixture is dry before reapplying power Service and repairs There are no user serviceable parts inside the fixture Do not open the housing Never try to repair the fixture by yourself as this may result in damage malfunction and it may potentially void your product warranty The equipment must only be serviced or repaired by an authorized RUSH by Martin service technician Installation on site service and maintenance can be provided worldwide by the Martin Professional Global Service organization and its approved agents givin
10. 5x5 fixtures in total at 200 240 V The voltage and frequency at the MAINS OUT socket are the same as the voltage and frequency applied to the MAINS IN socket Only connect devices to the MAINS OUT socket that accept this voltage and frequency RUSH STROBE 1 5x5 user manual 7 Protection from burns and fire Do not operate the fixture if the ambient temperature T exceeds 40 C 104 F The surface of the product casing can reach up to 65 C 149 F during operation Avoid contact by persons and materials Allow the fixture to cool for at least 10 minutes before handling Keep flammable materials well away from the fixture Keep all combustible materials e g fabric wood paper at least 100 mm 4 in away Ensure that there is free and unobstructed airflow around the fixture Provide a minimum clearance of 100 mm 4 in around fans and air vents Do not illuminate surfaces within 200 mm 7 9 ins of the fixture Do not attempt to bypass thermostatic switches or fuses Connect only other fixtures of the same type to the power throughput sockets Do not connect any other type of device to these sockets Do not stick filters masks or other materials onto any optical component Protection from eye injury Do not look continuously at LEDs from a distance of less than 8 3 meters 27 ft 3 inches from the front surface of the fixture without protective eyewear such as shade 4 5 welding goggles At less than this dis
11. STROBE 1 5x5 Gi D VW m S AAA CALAMA MAA o o e e e e MMMM gt MMMM AA A AY MAN User Manual Rest by Martin Professional Entertainment Technology 2013 Martin Professional ApS Information subject to change without notice Martin Professional and all affiliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual The Martin logo the RUSH by Martin logo the RUSH by Martin name the Martin name and all other trademarks in this document pertaining to services or products by Martin Professional or its affiliates and subsidiaries are trademarks owned or licensed by Martin Professional or its affiliates or subsidiaries Manual Revision B Table of contents Safety INIOFMATON star llas 5 INrodUcionisa Giai 10 Before using the product iii a iaia 10 Physical Install dai ads 11 eil Le Bt wn le aida 11 Mounting ON a EE 12 Ale EE 13 Linking fixtures to power in a chain 14 Fixture overview iii ia 15 Contrordala Incisione 17 Tips for reliable data transmission nennen 17 Connecting the DMX dataimk nennen nennen ennennnnnnn 18 FI UTESELUD adores A ds 19 Using the control MENUS
12. body such as TUV as a safety attachment for the weight that it secures The safety cable must comply with EN 60598 2 17 Section 17 6 6 and be capable of bearing a static suspended load that is ten times the weight of the fixture and all installed accessories Check that all external covers and rigging hardware are securely fastened Block access below the work area and work from a stable platform whenever installing servicing or moving the fixture Do not operate the fixture with missing or damaged covers shields or any optical component In the event of an operating problem stop using the fixture immediately and disconnect it from power Never attempt to use a fixture that is obviously damaged Do not modify the fixture or install other than genuine RUSH by Martin parts Refer any service operation not described in this manual to a qualified technician RUSH STROBE 1 5x5 user manual 9 Introduction The STROBE 1 5x5 is designed to provide blinder or pixel matrix chase effects This fixture has variable speed strobe effects built in light chases and provides the ability to create user defined chases as well as alphabetic and numeric characters in light via DMX The STROBE 1 5x5 is powered by twenty five flicker free 5 watt cool white LEDs laid out in a 5 x 5 pixel array Multiple STROBE 1 5x5s can be coupled together into a larger array The device is rugged lightweight and compact and is ideal for touring or small fixed
13. es three control modes enabling varying degrees of DMX control and enabling the efficient use of DMX channel bandwidth Each of these modes is documented in detail in DMX protocol on page 27 and they are summarized briefly here DMX channel Description mode 4 channels Sound activated stand alone line number or letter effects full range dimming and strobe effects 25 channels Dimming control of individual LED pixels 29 channels Dimming control of individual LED pixels Sound activated stand alone line number or letter effects full range dimming and strobe effects To set the fixture s DMX channel mode 1 Select LH 1d and press the ENTER button 2 Use the DOWN and UP buttons to select the i H S ZL Hi or SCH DMX channel mode 3 Once the mode has been selected press the ENTER button to set it or to return to a higher level of the menu structure without any change press the MENU button Show mode auto trig In the absence of a DMX control signal show mode provides standalone pre programmed light shows Show mode can be combined with sound activation to provide a music synchronized light show To set a fixture s show mode 1 Select Shite and press the ENTER button 2 Use the DOWN and UP buttons to select show 0 8 Shows 1 8 are pre programmed shows Show 0 executes a random show 20 RUSH STROBE 1 5x5 user manual 3 Once the mode has been selected press the ENTER button to set or to re
14. ey Place the two fixtures to be attached side by side and extend the hooks to connect them Mounting on a truss An individual fixture or array can be clamped to a truss or similar rigging structure When clamping to a truss 1 Check that the rigging structure can support at least 10 times the weight of all fixtures and equipment to be installed on it 2 Block access under the work area 3 Rig the fixture or array using clamps and hardware suitable for the purpose Fasten them to the screw holes in the fixture bracket Working from a stable platform hang the fixture on the truss Tighten the rigging clamps and hardware 4 Secure each and every fixture against clamp failure with a secondary attachment such as a safety cable that is passed through the safety cable mounting point on the rear of the fixture Secondary attachments must be approved for the weight of the fixture and fastened to the load bearing structure not to an adjacent fixture 12 RUSH STROBE 1 5x5 user manual AC power Read Safety information on page 5 before connecting the fixture to AC mains power Warning The mains power input cable supplied with the fixture is rated 6 A and can supply only one fixture with mains power Do not connect any device to the fixture s MAINS OUT power throughput socket when using this input cable If you want to connect other fixtures to the MAINS OUT socket see Linking fixtures to power in a chain on page 14 Fo
15. g owners access to Martin s expertise and product knowledge in a partnership that will ensure the highest level of performance throughout the product s lifetime Please contact your RUSH by Martin supplier for details 26 RUSH STROBE 1 5x5 user manual DMX protocol 4 channel mode SIE Value Function A E RUSH STROBE 1 5x5 user manual 27 Channel Value Function 224 231 Effect 28 slow to fast 232 239 Effect 29 slow to fast 248 255 Random line effect 2 2 Number mode see channel 1 16 35 56 75 76 95 116 135 136 155 240 247 Effect 30 slow to fast 36 55 96 115 156 175 176 195 196 215 216 235 Count up 0 9 slow to fast 236 255 Count down 9 0 slow to fast 2 3 Letter T 28 RUSH STROBE 1 5x5 user manual Chamnel Value Function A 8 137 Strobe slow to fast 132 139 RUSH STROBE 1 5x5 user manual 29 25 channel mode Channel Value Function 6 0 255 DimmerLED6 0 100 _______ 8 0 255 DimmerLED8 0 100 _________ 9 0 255 DimmerLED9 0 100 Dimmer LED 25 0 100 30 RUSH STROBE 1 5x5 user manual 29 channel mode Channel Value Function 4 5 12 13 14 15 16 17 Dimmer LED 21 0 100 26 E 1 Mode 27 1 RUSH STROBE 1 5x5 user manual 31 Channel Value Function 27 2 216 235 Count up 0 9 slow to fast 236 255 Count down 9 0 slow to fast 32 RUSH STROBE 1 5x5 user manual Chamnel Value Function 27 3 ET
16. he MENU button this will occur automatically after an interval where there has been no user input DMX addressing CI 11 TI I I The DMX address also known as the start channel is the first channel used to receive instructions from a DMX controller The fixture can be controlled using signals sent by a DMX controller on a number of channels 4 25 or 29 depending on the DMX mode that has been set Each DMX controlled fixture must have a DMX address set For example if a fixture has a DMX address of 10 and it is in 4 channel DMX mode then it uses channels 10 11 12 and 13 The following fixture in the DMX chain could then be set to a DMX address of 14 For independent control each fixture must be assigned its own control channels Two fixtures of the same type may share the same address if identical behavior is desired Address sharing can be useful for diagnostic purposes and symmetric control particularly when combined with the inverse pan and tilt options The DMX address is configured using the Htc menu in the control panel To set the fixture s DMX address 1 Select Add and press the ENTER button 2 Use the UP and DOWN buttons to select the address 1 to 512 3 Once the address has been selected press the ENTER button to set it or to return to a higher level of the menu structure without any change press the MENU button RUSH STROBE 1 5x5 user manual 19 DMX channel modes rir Lu The fixture provid
17. hite 16 RUSH STROBE 1 5x5 user manual Control data link A DMX 512 data link is required in order to control the fixture via DMX We recommend the use of a controller that has pixel mapping functionality The fixture has 3 pin and 5 pin XLR connectors for DMX data input and output The number of daisy chained fixtures is limited by the number of DMX channels required by the fixtures in relation to the maximum 512 channels available in one DMX universe Note that if independent control of a fixture is required it must have its own DMX channels Fixtures that are required to behave identically can share the same DMX address and channels To add more fixtures or groups of fixtures when the above limit is reached add a DMX universe and another daisy chained link Tips for reliable data transmission Use shielded twisted pair cable designed for RS 485 devices standard microphone cable cannot transmit control data reliably over long runs 24 AWG cable is suitable for runs up to 300 meters 1000 ft Heavier gauge cable and or an amplifier is recommended for longer runs The pin out on all connectors is pin 1 shield pin 2 cold and pin 3 hot Pins 4 and 5 in the 5 pin XLR connectors are not used in the fixture but are available for possible additional data signals as required by the DMX512 A standard Standard pin out is pin 4 data 2 cold and pin 5 data 2 hot To split the link into branches use a splitter such a
18. imum ambient temperature Ta Max 40 C 104 F Minimum ambient temperature Ta mm 5 C 41 F Total heat dissipation calculated 10 510 BTU hr Approvals EU safety EN 60598 2 17 EN 60598 1 EN 62471 EN 62493 EUEMO ee EN 55015 EN 55103 1 EN 55103 2 A EN 61000 3 2 EN 61000 3 3 EN 61547 IE esoo lei FCC Part 15 Class A Canadian EMG aaa ICES 003 Class A AustalalN KEE C TICK N4241 38 RUSH STROBE 1 5x5 user manual Included Items 1 5 m 5 ft power cable without power plug Mounting brackets including screws Accessories Cables 16 A for connection to power in chains Power input cable 14 AWG SJT 1 5 mm HO5VV F with PowerCon input connector 3 m 9 8 ft P N 11541508 Power relay cable 14 AWG SJT 1 5 mm HO5VV F with PowerCon connectors 1 4 m 4 6 ft P N 11541509 Power relay cable 14 AWG SJT 1 5 mm2 HO5VV F with PowerCon connectors 2 25 m 7 4 ft P N 11541510 Power relay cable 14 AWG SJT 1 5 mm HO5VV F with PowerCon connectors 3 25 m 10 7 ft P N 11541511 Power connectors Neutrik PowerCon NAC3FCA power input connector cable mount blue P N 05342804 Neutrik PowerCon NAC3FCB power output connector cable mount light grey P N 05342805 Related Items
19. one of the fixture s ventilation slots are blocked Fasten the fixture securely Do not stand it on a surface or leave it where it can be moved or can fall over Attach a securely anchored safety cable to the fixture if it is installed in any location where it may fall and cause injury or damage if the primary attachment fails If installing an array of multiple STROBE 1 5x5s ensure that each of then has a safety cable that is attached to the load bearing structure and not to an adjacent fixture Martin can supply suitable safety cables and rigging clamps for use with the fixture See Accessories on page 39 The fixture can be oriented at any angle Ensure that the mounting surfaces and hardware can support at least 10 times the weight of all fixtures and equipment to be installed on them Joining fixtures Multiple STROBE 1 5x5s can be joined together into an array Note that a single STROBE 1 5x5 fixture must never bear the weight of more than four other STROBE 1 5x5s that are hung beneath it and must never bear the weight of horizontally adjacent fixtures 1 When hanging one STROBE 1 5x5 beneath another remove the brackets at the top of the fixture 2 Each fixture has four built in attachment hooks age a two on the bottom and two on one side for IH o connecting fixtures These can be retracted OD a or extended using a 4 mm L shaped hex RUSH STROBE 1 5x5 user manual 11 wrench Allen k
20. r protection from electric shock the fixture must be grounded earthed The power distribution circuit must be equipped with a fuse or circuit breaker and ground fault earth fault protection Socket outlets or external power switches used to supply the fixture with power must be located near the fixture and easily accessible so that the fixtures can easily be disconnected from power Do not insert or remove live power connectors to apply or cut power as this may cause arcing at the terminals that will damage the connectors Do not use an external dimming system to supply power to the fixture as this may cause damage to the fixture that is not covered by the product warranty The fixture can be hard wired to a building electrical installation if you want to install it permanently or a power plug that is suitable for the local power outlets can be installed on the power cable If you install a power plug on the power cable install a grounding type earthed plug with integral cable grip that is rated minimum 250 V 6 A Follow the plug manufacturer s instructions and connect the wires in the power cable as shown in this table Live or L Neutral or N Earth Ground or US system Black White Green EU system Brown Blue Yellow green The fixture has an auto ranging power supply that accepts AC mains power at 100 240V 50 60 Hz Do not apply AC mains power at any other voltage or frequency to the fixture RUSH STROBE 1 5x5 user man
21. s the Martin 4 Channel Opto Isolated RS 485 Splitter Amplifier Terminate the link by installing a DMX termination plug in the output socket of the last fixture The termination plug which is a male XLR plug with a 120 Ohm 0 25 Watt resistor soldered between pins 2 and 3 soaks up the control signal so it does not reflect and cause interference If a splitter is used terminate each branch of the link RUSH STROBE 1 5x5 user manual 17 Connecting the DMX data link To connect fixtures to data 1 2 18 Connect the DMX data output from the controller to the first fixture s male XLR DMX input connector Connect this fixture s DMX output to the DMX input of the next fixture and continue connecting fixtures output to input Terminate the last fixture on the link as described above RUSH STROBE 1 5x5 user manual Fixture setup This section explains the fixture characteristics that can be set that determine how it can be controlled and will behave These settings are made using the menus available from the control panel and are retained even when the fixture is powered off Using the control menus See the map of the control menu structure in Control menus on page 34 To access the control menus press the MENU button Navigate the menu structure using the MENU ENTER DOWN and UP buttons Select any required menu option using the ENTER button To return to a higher level in the menu structure without any change press t
22. site service and maintenance can be provided worldwide by the Martin Professional Global Service organization and its approved agents giving owners access to Martin s expertise and product knowledge in a partnership that will ensure the highest level of performance throughout the product s lifetime Please contact Martin for details Cleaning Excessive dust smoke fluid and particle buildup degrades performance causes overheating and will damage the fixture Damage caused by inadequate cleaning or maintenance is not covered by the product warranty The cleaning of external optical lenses must be carried out periodically to optimize light output Cleaning schedules for lighting fixtures vary greatly depending on the operating environment It is therefore impossible to specify precise cleaning intervals for the fixture Environmental factors that may result in a need for frequent cleaning include e Use of smoke or fog machines e High airflow rates near air conditioning vents for example e Presence of cigarette smoke e Airborne dust from stage effects building structures and fittings or the natural environment at outdoor events for example If one or more of these factors is present inspect fixtures within their first 100 hours of operation to see whether cleaning is necessary Check again at frequent intervals This procedure will allow you to assess cleaning requirements in your particular situation If in doubt consult
23. tance the LED emission can cause eye injury or irritation At distances of 8 3 meters 27 ft 3 inches and above light output is harmless to the naked eye provided that the eye s natural aversion response is not overcome Do not look at LEDs with magnifiers telescopes binoculars or similar optical instruments that may concentrate the light output Ensure that persons are not looking at the LEDs from within 8 3 meters 27 ft 3 inches when the product lights up suddenly This can happen when power is applied when the product receives a DMX signal or when certain control menu items are selected RUSH STROBE 1 5x5 user manual To minimize the risk of eye irritation or injury disconnect the fixture from power at all times when the fixture is not in use and provide well lit conditions to reduce the pupil diameter of anyone working on or near the fixture Protection from injury Fasten the fixture securely to a fixed surface or structure when in use The fixture is not portable when installed Ensure that any supporting structure and or hardware used can hold at least 10 times the weight of all the devices they support If suspending from a rigging structure fasten the fixture to a rigging clamp Do not use safety cables as the primary means of support If the fixture is installed in a location where it may cause injury or damage if it falls install a secondary attachment such as a safety cable that is approved by an official
24. this manual and printed on the product Keep this user manual for future use For the latest user documentation and other information for this and all Martin products please visit the Martin website at http www martin com Protection from electric shock Do not expose the fixture to rain or moisture Disconnect the fixture from AC power before carrying out any installation or maintenance work and when the fixture is not in use Ensure that the fixture is electrically connected to ground earth Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault earth fault protection Socket outlets or external power switches used to supply the fixture with power must be located near the fixture and easily accessible so that the fixture can easily be disconnected from power Replace defective fuses with ones of the specified type and rating only Isolate the fixture from power immediately if the power plug or RUSH STROBE 1 5x5 user manual any seal cover cable or other component is damaged defective deformed wet or showing signs of overheating Do not reapply power until repairs have been completed Before using the fixture check that all power distribution equipment and cables are in perfect condition and rated for the electrical requirements of all connected devices Use only Neutrik PowerCon cable connectors to connect to the fixture s power socke
25. ton to set or to return to a higher level of the menu structure without any change press the MENU button LED display on off To set the LED display to be on all the time or to automatically switch off when not in use 1 Select Leo menu and press the ENTER button 2 Use the DOWN and UP buttons to select the ON LED on or OFF LED off when not in use Press the ENTER button to set or to return to a higher level of the menu structure without any change press the MENU button LED display inversion To invert the LED display Select d OF menu and press the ENTER button 2 Use the DOWN and UP buttons to select the dt SP normal display orientation or do iP invert display Press the ENTER button to set or to return to a higher level of the menu structure without any change press the MENU button sech Auto test To perform a complete test of all of the fixture functions 1 Select Ee St and press the ENTER button The fixture will run a self test routine 2 To return to a higher level of the menu structure press the MENU button 22 RUSH STROBE 1 5x5 user manual Fixture time To display the fixture s operating hours counter 1 Select bur Sl and press the ENTER button The display will show the number hours the unit has been run 2 To return to a higher level of the menu structure press the MENU button Firmware version To display the fixture s installed firmware version number
26. ts Do not connect devices to power in a chain that will exceed the electrical ratings of any cable or connector used in the chain The supplied power input cable is rated 6 A and can safely supply only one fixture with mains power Do not connect any device to the fixture s MAINS OUT connector when using this cable If you replace this cable and also use the replacement cable to supply only one fixture with mains power the replacement cable must also be rated 6 A minimum have three conductors 18 AWG or 0 75 mm minimum conductor size have an outer cable diameter of 6 15 mm 0 2 0 6 in and be temperature rated to suit the application In the USA and Canada the cable must be UL listed type SJT or equivalent In the EU the cable must be type HO5VV F or equivalent To connect fixtures to mains power in a chain you must first obtain 14 AWG or 1 5 mm power input and throughput cables that are 16 A rated and temperature rated to suit the application In the USA and Canada the cables must be UL listed type SJT or equivalent In the EU the cables must be type HOSVV F or equivalent Suitable cables with Neutrik PowerCon connectors are available from Martin see Accessories on page 39 If you use these cables you can connect fixtures to power in a linked chain MAINS OUT throughput socket to MAINS IN input socket but do not link more than e Two 2 RUSH Strobe 1 5x5 fixtures in total at 100 120 V or e Four 4 RUSH Strobe 1
27. turn to a higher level of the menu structure without any change press the MENU button Manual settings To dl sel individual dimmer or strobe settings 1 Select jul nul and press the ENTER button 2 Use the DOWN and UP buttons to choose d H dimmer or Sk ro strobe Press the ENTER button to select or to return to the higher level of the menu structure without any change press the MENU button 3 Use the DOWN and UP buttons to specify a value for the chosen effect from O to 255 4 To return to a higher level of the menu structure press the MENU button Sound activation music trig Sola The fixture has a built in microphone that can be used to synchronize its behavior to the beat of music When the fixture is not connected to a DMX controller and is running in Show Mode it can be set to trigger effect changes in synch with music To turn on sound activation 1 Select Sol inland press the ENTER button 2 Use the DOWN and UP buttons to select Lan ii sound activation on or off sound activation off 3 Once the mode has been selected press the ENTER button to set it or to return to a higher level of the menu structure without any change press the MENU button Blackout You can blackout the fixture using the control menu 1 Select bi ir and press the ENTER button RUSH STROBE 1 5x5 user manual 21 2 Use the DOWN and UP buttons to select YES blackout or NO do not blackout Press the ENTER but
28. ual 13 Linking fixtures to power in a chain If you obtain a 14 AWG 1 5 mm power input cable and 14 AWG 1 5 mm throughput cables from Martin see Accessories on page 39 you can relay mains power from one fixture to another by connecting fixtures to power in a linked daisy chain MAINS OUT throughput socket to MAINS IN input socket Using 14 AWG or 1 5 mm cables from Martin you can link e Maximum two 2 RUSH Strobe 1 5x5 fixtures in total at 100 120 V or e Maximum four 4 RUSH Strobe 1 5x5 fixtures in total at 200 240 V If you install a power plug on the 14 AWG 1 5 mm power input cable available from Martin install a grounding type earthed plug with integral cable grip that is rated minimum 16 A 250 V 14 RUSH STROBE 1 5x5 user manual Fixture overview caa gt H 1 3 8 5 pin XLR DMX inputs and outputs 2 Control panel and display The fixture has two LEDs next to the display on the rear of the fixture DMX on DMX input present Flashing Sound activation Activate the menu mode functions or Return to the previous level of the menu structure or Press and hold to exit the menus DOWN Go down a menu branch Go up a menu branch ENTER Confirm the selected function 3 Microphone for sound activation in music trig operation RUSH STROBE 1 5x5 user manual 15 4 Safety cable attachment point 5 Mains power input PowerCon blue and throughput PowerCon w
Download Pdf Manuals
Related Search
Related Contents
OmniMount OC80FM flat panel wall mount Kicker ZX460 Amplifier Owner's Manual Le gonflage des bouteilles New Bigfoot GAP User guide - V-Data 取扱説明書 Jex Professionnel Crème à Récurer LED 電源取扱説明書 - Shindengen di macchine - International Labour Organization en otra ventana Cables Direct Round Floppy Drive Cable Copyright © All rights reserved.