PEony-12 Installation Guide (Version 1.5.0)

image

Contents

1. PEony 12 Installation Guide 2010 2011 SemiPXI www semipxi com Rev 1 5 0 PEony 12 Installation Guide subject to change without notice Page 1 of 13 PEony 12 Change History Revision Date Author Remarks 1 0 0 16 July 2010 Ivan Chen First Release 1 1 0 9 December 2010 Michael Xu Updated pictures 1 5 0 26 January 2011 Michael Xu Minor corrections Pictures update For release together with V150 driver release 2010 2011 SemiPXI PEony 12 Installation Guide subject to change without notice www semipxi com Rev 1 5 0 Page 2 of 13 PEony 12 Table of Contents 1 Hardware Installation erororrnnnnrrrrrrrroonnnnnnnrrrrnnrrnnnnnnnnnnrnnnnrssnnnnnnnnrvnnnsssnnnnnn 1 1 Install FlexRIO and PEN saadan aebadkudkundosinkae 1 2 Power On SCQUENCE siisii nna ea rin rainei 2 Software Installaatio Nsei arirn ie ot cones eects xh gk EREE EEE EE AE ER E ia 2 1 Install Software Components uuuumumnemumiiusrivsv vinene 2 2 FlexRIO Resource Name srrrrnnsnnrrnnssnnnvnnnsnnnnvenesnnnvnnssnnnnvnnssnnnrnnsssnnnvesssnns J Calibrati n Data usanne 4 Devloping Applications uumuoesmassmsrdmjsunsnmiidnnnsrinejaisaisa List of Figures Figure 1 Insert FlexRIO Modul Lunumemnanrdvunnunvelsv paien Figure 2 Fasten FIexRIO Scr ws uummuuunsomumnasbettumn tau Figure 3 Insert Lily Module Lav messamemie tene a Figure 4 Fasten Lily Samtec Cable uyunrumusememreramepemnnvkmmvoime Figure 5 Connector NO
2. ation LabVIEW Run Time 9 0 Measurement amp Automation Explorer File Edit View Tools Help Cont iguration Q My System a TR a lell Data Neighborhood oe osb Aint g a AN PEARU R PIE f 9 0 0 LabYIEW Run Time Engine amp 4 Scales 1 Software IVI Compliance Package 4 0 LabVIEW Run Time 7 1 F LabVIEW Run Time 8 0 1 J Labview Run Time 8 2 1 F LabvIEW Run Time 8 5 1 J LabVIEW Run Time 8 6 1 EP 31 sbyIEW Run Time 9 0 LabVIEW SignalExpress 2009 LabWindows CVI Run Time 9 0 1 QI Measurement amp Automation Explorer 4 6 amp 9 Measurement Studio for V52005 h NI Spy 2 7 F n1 488 22 71 Eg NI DAQmx 8 9 5 NIPAL 2 4 1 Figure 10 Verify Software Version 2010 2011 SemiPXI www semipxi com Rev 1 5 0 PEony 12 Installation Guide subject to change without notice Page 10 of 13 PEony 12 2 2 FlexRIO Resource Name After installing all the software components please take note of the FlexRIO resource name in NI Measurement amp Automation as shown in Figure 11 below Alias names are NOT supported More than one FlexRIO cards can be inside the same system to support multiple PEony cards and they will be identified by their resource names e g RIOO RIO1 RIO2 etc amp RIGO Measurement amp Automation Explorer Mel File Edit View Tools Help Configuration K Refresh hp Save fA Reve 2 Show Help g Q My System Pr all Data Neighborhood Status a Fy D
3. auto deeedadleieiude edda adddduaedd Figure 5 Cable Female Se secaed iasoassiesisaanticddsisnastiasitanaend tana Geadwasieveapuunddnaidionnstd Figure 7 Fasten PEony Samtec Cable rssnrrnnaannnvrnnnnnnnvenesnnnvvnnsnnnnvenssrnnvrnsssnnnee Figure 8 12V Power Input Connector rnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnenene Figure 9 Complete UP lnkedskrdadauedijen Figure 10 Verify Software Version mrrrrrrarnnrrvrerrnnvvnernnnrvevssnnnvvessrsnnrenssennreessee Figure 11 FlexRIO Resource Name siccmatsiiceswuccsacesnadsidernceindivastsaptanserieersassieecersanes 2010 2011 SemiPXI www semipxi com PEony 12 Installation Guide subject to change without notice Rev 1 5 0 Page 3 of 13 PEony 12 1 Hardware Installation Follow the steps below to complete the hardware installation 1 1 Install FlexRIO and PEony 1 Power off the PXI chassis before installing the module 2 Remove the packaging material on the FlexRIO PXI connector and screws 3 Slide the FlexRIO module into an empty PXI slot as shown in Figure 1 below Figure 1 Insert FlexRIO Module BS As at the release time of this document only FlexRIO PXI 7952R and PXI 7954R are supported 2010 2011 SemiPXI www semipxi com Rev 1 5 0 PEony 12 Installation Guide subject to change without notice Page 4 of 13 EF ah PEony 12 a 4 Slide the module completely into the chassis and latch it by fastening the screws which are highl
4. description of all the available DLL funtions and LabVIEW 2009 VI funtional driver refer to PEony 12 DLL Functional Driver User Manual or PEony 12 LabVIEW VI Functional Driver User Manual 2010 2011 SemiPXI www semipxi com Rev 1 5 0 PEony 12 Installation Guide subject to change without notice Page 13 of 13
5. evices and Interfaces amp gg NI DAQmx Devices PX PXI System Unidentified a EE RIO Devices 2 E Serial amp Parallel H Scales Identification a 61 Software Resource a f IVI Drivers g Remote Systems A This device is working properly RIO Alias on My System Product Information Vendor National Instruments Product NI PXI 7952R Serial Number 014423D2 Location Chassis Slot Bus Device PF General Figure 11 FlexRIO Resource Name 2010 2011 SemiPXI www semipxi com Rev 1 5 0 PEony 12 Installation Guide subject to change without notice Page 11 of 13 PEony 12 3 Calibration Data Calibration data is stored in the EEPROM onboard PEony The first time you run Initialization on a new system remote PC connected to the PXI system or PXI embedded controller it will take a couple of minutes for the software driver to load the calibration data from the EEPROM Subsequently software driver will load the data from a calibration file thus speed up the loading of calibration data 2010 2011 SemiPXI www semipxi com Rev 1 5 0 PEony 12 Installation Guide subject to change without notice Page 12 of 13 PEony 12 4 Devloping Applications Custom applications can be developed using PEony s 32 bit DLL funtional driver or LabVIEW 2009 VI funtional driver The following driver APIs are provided e PeonyDriver dll amp PeonyDriver h e LabVIEW VI funtional driver zip For detailed
6. ighted by the red circle in the following picture Figure 2 Fasten FlexRIO Screws 5 Now take the Lily adapter module for FlexRIO and plug it into the NI FlexRIO s front panel slot Fasten the screws that are highlighted by the red circles in Figure 3 Figure 3 Insert Lily Module 2010 2011 SemiPXI Rev 1 5 0 PEony 12 Installation Guide subject to change without notice Page 5 of 13 6 Plug the Samtec cable connector onto the Lily adapter module and fasten the screws which are highlighted by the red circle in Figure 4 Take note to align the connector notch areas at the corners as highlighted by the red circles in Figure 5 TR RR So esau lei Figure 5 Connector Notch 2010 2011 SemiPXI www semipxi com Rev 1 5 0 PEony 12 Installation Guide subject to change without notice Page 6 of 13 PEony 12 7 Plug the Samtec cable s female side to PEony card s back end connector Again take note of the notch area highlighted by red circles in Figure 6 Fasten the screws that are highlighted by the red circles in Figure 7 Do NOT over tighten the screws Figure 6 Cable Female Side Figure 7 Fasten PEony Samtec Cable 2010 2011 SemiPXI www semipxi com Rev 1 5 0 PEony 12 Installation Guide subject to change without notice Page 7 of 13 PEony 12 8 Supply 12 V to PEony 12 power input connector using a desktop power supply as shown in Figure 8 Middle 2 pins of the connector are 12V input and the 2 side
7. pins are ground signals Figure 8 12V Power Input Connector 2010 2011 SemiPXI www semipxi com Rev 1 5 0 PEony 12 Installation Guide subject to change without notice Page 8 of 13 PEony 12 1 2 Power On Sequence 1 If you re using the PC Laptop MXI Express card to control the PXI chassis please remember to power on the PXI chassis first before turning on PC Laptop computer 2 If you are using PXI embedded controller power on the controller Turn on PEony 12V power supply 4 Figure 9 below shows the complete set up PEony 12 digital pin card is inside the right hand side box This chassis can be customized to suit different applications as well as to accommodate more PEony cards a D urs LOWPOWEH PAE Figure 9 Complete Set up 2010 2011 SemiPXI www semipxi com Rev 1 5 0 PEony 12 Installation Guide subject to change without notice Page 9 of 13 PEony 12 2 Software Installation 2 1 Install Software Components The following software components must be installed prior to the use of PEony 12 Use Measurement amp Automation Explorer to verify the software version see Figure 10 below e NI LabVIEW Run Time Engine 9 0 http joule ni com nidu cds view p id 1383 lang en e NI RIO 3 2 1 http joule ni com nidu cds view p id 1386 lang en e NI PXI Platform Services 2 5 1 http joule ni com nidu cds view p id 1381 lang en This driver is typically included with NI RIO hardware driver install