1. Addr is displayed Scroll through using the UP or DOWN buttons until FLSH is displayed Press ENTER The Display will now show FL_ _ number Using the UP or DOWN buttons choose between FLOO FL51 FLOO Slowest FL51 Fastest strobe speed Blackout Mode Blackout mode lets you turn off ALL light output regardless of what op erating mode it is set in 1 Press MENU until Addr is displayed 2 Scroll through using the UP and DOWN buttons until BLND is displayed 3 Press ENTER 4 The Display will now show YES or NO 5 Choose YES for Blackout Choose NO for LED s on 6 Press ENTER to Confirm your choice Display Settings If you mount the fixture upside down it will make it awkward to set the modes so this feature lets you turn the display upside down too 1 Press MENU until Addr is displayed 2 Scroll through using the UP or DOWN buttons until dISP is displayed 3 Press ENTER 4 The Display will now show YES or NO 5 Choose YES for upside down NO for normal view 6 Press ENTER to confirm your choice NOTE when the display is upside down the MODE button be comes the ENTER button and the ENTER BUTTON becomes the MODE button DMX Mode Channels Addressing The icon can be set to operate with 2 DMX Channels or 8 DMX Chan nels 1 Press MENU until Addr is displayed 2 Scroll through using the UP or DOWN buttons until CHnd is di
2. Lex Lighting Safety Instructions LI GHTI N G 1 Please keep this User Manual for future reference and be sure to pass this manual on to anyone using the fixture 2 Always make sure that you are connecting to the proper voltage as stated on the decal or rear panel of the fixture 3 This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rain or moisture 4 Make sure there are no flammable materials close to the unit while operating 5 The unit must be installed in a location with adequate ventilation atleast 20inches 50 cm from adjacent surfaces Be sure that no ventilation slots are blocked 6 Always disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse rating 7 Secure fixture to fastening device using a safety chain 8 Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this 9 In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction and will void your warranty Please contact the nearest authorized technical assistance center 10 Never connect the device to a dimmer pack 11 Make sure the power cord is never crimped or damaged 12 Never disconnect the power cord by pulling or tugging on the cord 13 Never carry the fixture directly from th
3. con will now go through each steps of the selected Pattern at the choosen speed QUICK TIP The Digital Display of your ICON will turn off after 30 seconds To change the speed again simply press any button The display will turn back on showing SP__ Speed you chose before simply press the UP and DOWN buttons to alter the speed Static Mode Color Select amp Strobe modes Static mode is where the LED s are Static whcih creates a floodlight type effect You can choose what colours or a combination of col ours Follow the steps below d 2 Press MENU until Addr is displayed Scroll through using the UP and DOWN buttons until COLO is displayed Press ENTER The Display will now show CO_ _ number Using the UP and DOWN buttons choose between C001 C015 Press ENTER Your icon will now display you choosen colour or combination of col ours ina STATIC flood effect Below are the values of each colour effect C001 WHITE C002 BLUE C003 BLUE WHITE C004 GREEN C005 GREEN WHITE C006 GREEN BLUE C007 GREEN BLUE WHITE C008 RED C009 RED WHITE C010 RED BLUE C011 RED WHITE BLUE C012 RED GREEN CO13 RED GREEN WHITE C014 RED GREEN BLUE C015 RED GREEN BLUE WHITE ALL LEDS ON When you have selected your desired colour s you can either leave it static as shown above or you can have them flash strobe 1 2 3 4 5 6 Put the fixture in Static as shown above Press MENU until
4. e cord Always use the hanging mounting bracket 14 Avoid direct eye exposure to the light source while it is on Lexicon USER MANUAL Please read through the manual before operating this product Keep in a safe place for future reference pon www lexlighting co uk Congratulations on purchasing your new lighting effect from Lexlighting Reading through this manual will ensure trouble free and long life operation of the unit Features 256 LED s Red Green Blue amp White Sound To Light Inbuilt Microphone Full DMX 2 or 8 Channels selectable Master Slave Mode Digital Settings Display Contents Light Unit Lexicon IEC Mains Cable UK Plug User Manual MODE UP DOWN ENTER MENU Configuration Chart Digital Display A001 A512 Sets the fixture DMX Address SPEE SP00 SP99 Sets the speed of the Auto Run Patterns SP00 Slow SP99 Fast COLO C001 C015 Sets the LED Colours FLSH FLOO FL51 Sets the Flash Strobe Speed FLOO Slow FL51 Fast CHND 2CH or 8CH Sets the fixture to have 2 DMX channels or 8 DMX Channels AUTO SHOO SH12 Selects 1 of the Auto Run Patterns pre programmed to the fixture SOUN none This simply puts the unit into Sound Light Mode using the inbuilt Microphone BLND YES or NO Turns off all LED s YES All Off NO ON dISP YES or NO Allows you to alter which way the Digital Display is displayed NO Normal Yes Upside down Simply makes y
5. our ICON a slave Sound to Light Sound Active Mode To put your icon into sound active mode simply follow the steps below 1 Press MENU 2 Scroll through using UP and DOWN buttons until SOUN is displayed 3 Press ENTER 4 Adjust the Sensitivity Dial as required Your fixture is now in Sound Active mode and will go through all of its internal patterns one by one activated by the sound from its in built microphone Auto Run Mode amp Pattern Selection amp Speed Auto mode is where the unit will go through it s pre programmed pat terns one by one regardless of any sound input The user can choose the pattern and the Pattern speed First lets get your fixture into AUTO Play mode 1 2 Press MENU Scroll through using UP and DOWN buttons until AUTO is displayed Press ENTER The display will now show SH_ _ number Using the UP and DOWN buttons choose between SHOO SH12 these are different program pattern modes Press ENTER You Icon will now go each steps of the selected Pattern It is possible to adjust the SPEED of the pattern steps Follow the steps below 1 Put the fixture in AUTO as shown above 2 3 Scroll through using the UP or DOWN buttons until SPEE is Press MENU until Addr is displayed displayed Press ENTER The Display will now show SP_ _ number Using the UP and DOWN buttons choose between SP00 SP99 SP00 slowest SP99 fastest Your I
6. port 2 Press MENU until Addr is displayed 3 Scroll through until SLA is displayed 4 Press ENTER Simply add another slave by copying above Up to 24 Slaves can be used per one master
7. splayed 3 Press ENTER 4 Choose between 8CH or 2CH 5 Press ENTER to confirm your choice DMX Mode DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions from the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures The ICON is a DMX enabled fixture and the DMX mode and DMX address settings are controlled via the Digital control panel It also carries the standard 3 pin XLR connections for DMX use To set your fixture for use with a universal DMX controller 1 Press MENU until Addr is displayed 2 Press ENTER 3 Display will show A__ _ number 4 Choose between A001 A512 5 Press ENTER to confirm your choice Your icon is now set at the DMX value you chose on the DMX uni verse Please consult the manual of your DMX controller for more informa tion on addressing fixtures See Channel Config table at the rear of the manual Master Slave Mode Master Slave is where one ICON will be set to the master and any other ICONS will copy it This is achieved by linking each ICON to gether using 3 PIN XLR cables and the DMX ports found at the rear MASTER ICON 1 Put master into Sound Auto Static Strobe Mode 2 Connect XLR to the DMX OUT port SLAVE ICON 1 Connect XLR cable to the DMX IN
Download Pdf Manuals
Related Search
Related Contents
Prova - Calcule Mais Installation/Care/Use Manual Manual de Instalación/Cuidado D Herzlichen Glückwunsch zu Ihrem XXL-Match-Lighter! DeLOCK 1.0m SATA M/M Broan-NuTone 680FL Combination Light Fan Exhaust Fan Coopération documentaire régionale, faits et chiffres Android User manual Bosch PS50-2BL Use and Care Manual Copyright © All rights reserved.