1. NEUTRAL AU NC1 LIVE NO1 S1 S2 INTRODUCTION The in wall MicroModule Motor Controller is designed to switch rise lower roller shutter connected to its terminals using radio waves controllers and a push button directly connected to this Roller Controller This in wall MicroModule Motor Controller is a transceiver which is a Z WaveTM enabled device and is fully compatible with any Z WaveTM enabled network Slim design let the Controller can easily hide itself into the wall box and that will be good for the house decoration The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of Roller Shutter This in wall MicroModule Motor Controller is able to detect position of the Shutter by using the patterned power measuring method so it can be remote controlled not only fully up or down but also can be adjusted to ex 30 or 50 And when manual controlled by push button the controller also can memorize the position and send the new shutter position to its controller ex IP Gateway www zipato com FEATURES Adopt newest Z wave 400series chip support multichannel operation and higher data rate 9 6 40 100kbps Adopt Z Wave protocol to secure the success of wireless two way communication Higher RF output power 2 5dBm output power as compared to 2 5dBm 300 series Z wave module to enhance the communication range With zero crossing te
2. VACA everything under control MICROMODULE MOTOR CONTROLLER QUICK re a GUIDE v1 TRADEMARKS Zipato and the Zipato logo are registered Trademarks All other product names mentioned herein may be trademarks or registered trademarks of their respective companies NOTICE Although Zipato has attempted to ensure the accuracy of the content of this manual it is possible that this document may contain technical inaccuracies typographical or other errors Zipato assumes no liability for any error in this publication and for damages whether direct indirect incidental and consequential or otherwise that may result from such error including but not limited to loss of data or profits Zipato provides this publication as is without warranty of any kind either express or implied including but not limited to implied warranties of merchantability or fitness for a particular purpose The published information in the manual is subject to change without notice Zipato reserves the right to make changes in the product design layout and driver revisions without notification to its users This version of the Installation guide supersedes all previous versions ELECTROMAGNETIC COMPATIBILITY In proper state and when operated properly the product complies with all the requirements in respect of interference radiation according to EN 301 489 17 EN 301 489 1 and EN 300 328 The connections conducting HF signals must ne
3. 0x00 W make your home smart Precision 1 Scale 0x02 W Meter Value 2 0x00 W Size 4 Bytes Meter Value Meter Value 3 0x03 W Meter Value 1 W MSB Meter Value 4 OxEA W Meter Value 2 W Meter W Meter Value 3 256 Meter Value 3 W Meter Value 4 100 2W Meter Value 4 WJLSB Accumulated Power Consumption KW h When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x00 Meter Report Command Command Class Meter0Meter Report scale bit 2 Rate Type Meter Type Precision Scale bit 1 0 Size Meter Value 1 Meter Value 2 Meter Value 3 Meter Value 4 Rate Type 0x01 Example Meter Type 0x01 Scale 0x00 KWh Precision 2 Precision 2 Scale 0x00 KWh Size 4 Bytes KW h Size 4 bytes Meter Value Meter Value 1 0x00 KWh Meter Value 1 KWh MSB Meter Value 2 0x01 KWh Meter Value 2 KWh Meter Value 3 0x38 KWh Meter Value 3 KWh Meter Value 4 0xA3 KWh Meter Value 4 KWh LSB Accumulated power consumption KW h Meter Value 2 65536 Meter Value 3 256 Meter Value 4 800 35 KW h AC load Voltage V When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x04 V Meter Report Command Command Class Meter Meter Report scale bit 2 Rate Type
4. MICROMODULE MOTOR CONTROLLER QUICK re a GUIDE v1 TECHNICAL SUPPORT Having trouble installing your new product Zipato s website contains the latest user documentation and software updates for Zipato products and services www zipato com CONTACT SUPPORT E MAIL support azipato com Mon Fri 9 00am 05 00pm CET MODELS AND FREQUENCIES MODELS EUROPEAN UNION EU version ph pan08 eu UNITED STATES US version ph pan08 us RUSSIA RU version ph pan08 ru ISRAEL IS version ph pan08 is AUSTRALIA AU version ph pan08 au INDIA IN version ph pan08 in FREQUENCIES EUROPEAN UNION EU 868 42 MHz UNITED STATES US 908 42MHz RUSSIA RU 869 02MHz ISRAEL IS 916 02MHz AUSTRALIA AU 921 42MHz INDIA IN 865 20MHz LIMITED PRODUCT WARRANTY GENERAL TERMS Nothing in this Limited Product Warranty affects your statutory rights as a consumer The Limited Product Warranty set forth below is given by Tri plus grupa d o o Europe herein referred to as ZIPATO This Limited Product Warranty is only effective upon presentation of the proof of purchase Upon further request by ZIPATO this warranty card has to be presented too EXCEPT AS EXPRESSLY SET FORTH IN THIS LIMITED WARRANTY ZIPATO MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ZIPATO EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED
5. Meter Type Precision Scale bit 1 0 Size Meter Value 1 Meter Value 2 Rate Type 0x01 Example Meter Type 0x01 Scale 0x04 V Precision 1 Precision 1 Scale 0x04 V Size 2 2 Bytes of V Size 2 Bytes Meter Value Meter Value 1 0x09 V Meter Value 1 High Byte V Meter Value 2 0x01 V Meter Value 2 Low Byte V AC load Voltage Meter Value 1 256 Meter Value 2 230 5 V AC load current 1 When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x05 1 Meter Report Command Command Class Meter Meter Report scale bit 2 Rate Type Meter Type Precision Scale bit 1 0 Size Meter Value 1 Meter Value 2 Rate Type 0x01 Example Meter Type 0x01 Scale 0x05 I Precision 2 Precision 2 Scale 0x05 1 Size 2 2 Bytes of Size 2 Bytes Meter Value Meter Value 1 0x01 I Meter Value 1 High Byte I Meter Value 2 0x21 I Meter Value 2 Low Byte I AC load current Meter Value 1 256 Meter Value 2 2 89 A www zipato com Load power factor PF When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter Report scale bit 2 Rate Type Meter Type Precision Scale bit 1 0 Size Meter Value 1 Rate Type 0x01
6. Example Meter Type 0x01 Scale 0x06 PF Precision 2 Precision 2 Scale 0x06 PF Size 1 1 Byte of PF Size 1 Bytes Meter Value 1 0x63 PF Meter Value 1 Load power factor PF Meter Value 1 0 99 Reset Accumulated Power Consumption KWh This command is to reset the Accumulated Power Consumption KWh to 0 Meter Reset Command Command Class Meter Meter Reset Alarm Report Command When MM Motor Controller detect Overload it will send Alarm_Report to Group1 Alarm Type 0x08 Alarm Level 0xFF When receive Alarm_Get command and the MM Motor Controller not in overload status it will send Alarm_Report Alarm Type 0x08 Alarm Level 0x00 Alarm Report When in Two Push Button switch type S1 or S2 close to L and not been release and MM Motor Controller receive some control moving command from Z Wave RF Ex BASIC_SET BINARY_SWITCH_SET MULTILEVEL_ SWITCH_SET MULTILEVEL_SWITCH_START_LEVEL CHANGE or MULTILEVEL_SWITCH_STOP_LEVEL_CHANGE MM Motor Controller won t do any movement change but report alarm to Group this indicate that the S1 or S2 not been released When MM Motor Controller detect a overload power it will report alarm to Group1 Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level OxFF Overload Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0x00 Normal When in Two Push Button switch type S1 or S2 are closed and not released to open and MM M
7. IN THIS LIMITED WARRANTY ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED IN DURATION TO THE LIMITED WARRANTY PERIOD TO THE EXTENT ALLOWED BY LOCAL LAW THE REMEDIES IN THIS WARRANTY STATEMENT ARE CUSTOMER S SOLE AND EXCLUSIVE REMEDIES AGAINST ZIPATO THEY DO NOT HOWEVER AFFECT OR RESTRICT THE RIGHTS YOU HAVE AGAINST THE BUSINESS YOU BOUGHT A ZIPATO PRODUCT FROM IN NO EVENT WILL ZIPATO BE LIABLE FOR LOSS OF DATA OR FOR make your home smart INDIRECT SPECIAL INCIDENTAL CONSEQUENTIAL INCLUDING LOST PROFIT OR DATA OR OTHER DAMAGE WHETHER BASED IN CONTRACT TORT OR OTHERWISE HOWEVER NOTHING IN THIS AGREEMENT LIMITS ZIPATO S LIABILITY TO YOU I IN THE EVENT OF DEATH OR PERSONAL INJURY TO THE EXTENT RESULTING FROM ZIPATO S NEGLIGENCE OR II TO THE EXTENT RESULTING FROM ANY FRAUDULENT MISREPRESENTATION ON THE PART OF ZIPATO OR III TO THE EXTENT ARISING UNDER PART 1 OF THE CONSUMER PROTECTION ACT 1987 OF THE UNITED KINGDOM SOME STATES OR COUNTRIES DO NOT ALLOW 1 A DISCLAIMER OF IMPLIED WARRANTIES 2 A LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR 3 LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR CONSUMER PRODUCTS IN SUCH STATES OR COUNTRIES SOME EXCLUSIONS OR LIMITATIONS OF THIS LIMITED WARRANTY MAY NOT APPLY TO YOU THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS THAT MAY VARY FROM STATE TO STATE OR FROM COUNTRY TO COUNTRY YOU ARE ADVIS
8. Basic Basic Set Value 0x63 or OxFF top or down to the bottom the execution of auto inclusion is free from pressing the Include control the shutter to the top OxFF button on the MM Motor Controller CHOOSING A SUITABLE LOCATION E E ee A ee Command Class Multilevel Switch Multilevel Switch Start Level Change Up Down Value The table below lists an operation summary of basic Z Wave shutter to the bottom 0x00 functions Please refer to the instructions for your Z Wave Certificated Primary Controller to access the Setup function and Do not locate the MM Motor Controller facing direct sunlight Command Class Basic Basic Set Value 0x01 0x62 control Up Down Bit to include exclude associate devices humid or dusty place the shutter to the position between bottom and top If Up Down Bit 0x00 Shutter move up The suitable ambient temperature for the MM Motor Controller is If Up Down Bit 0x01 Shutter move down 0 C 40 C BINARY SWITCH COMMAND CLASS If Up Down Bit 0x03 no move Function Description The Z Wave Controller does No node ID not allocate a node ID to the MM Motor Controller Have Z Wave Controller entered inclusion mode Inelueion Pressing Include button three times within 1 5 seconds will enter inclusion mode Have Z Wave Controller entered exclusion mode Pressing Include button three Exclusion times within 1 5 seconds will enter exclusion mode Node ID has been excluded
9. ED TO CONSULT APPLICABLE STATE OR COUNTRY LAWS FOR A FULL DETERMINATION OF YOUR RIGHTS This Limited Product Warranty applies to ZIPATO branded hardware products collectively referred to as ZIPATO Hardware Products sold by ZIPATO Europe its European subsidiaries affiliates authorized resellers or country distributors collectively referred to as ZIPATO Resellers with this Limited Product Warranty The term ZIPATO Hardware Product is limited to the hardware components and all its internal components including firmware The term ZIPATO Hardware Product DOES NOT include any software applications or programs GEOGRAPHICAL SCOPE OF THE LIMITED PRODUCT WARRANTY This Limited Product Warranty is applicable to Hardware Products sold by Zipato Resellers in all countries listed at the beginning of this document under the heading Countries in which this ZIPATO Limited Product Warranty applies The Limited Product Warranty will be honored in any country where ZIPATO or its authorized service providers offer warranty service subject to the terms and conditions set forth in this Limited Product Warranty However warranty service availability and response times may vary from country to country and may also be subject to registration requirements LIMITATION OF PRODUCT WARRANTY ZIPATO warrants that the products described below under normal use are free from material defects in materials and workmanship during the L
10. Pressing Include button three times within 1 5 seconds will enter inclusion mode Within 1 second press Include EEE button again for 5 seconds until LED is off IDs are excluded Have Z Wave Controller entered association mode OR Association Pressing Include button three times within 1 5 seconds will enter association mode LED Indication 2 second on 2 second off One press one flash One press one flash 2 second on 2 second off One press one flash 2 second on 2 second off One press one flash make your home smart Do not locate the MM Motor Controller where exists combustible substances or any source of heat e g fires radiators boiler etc After putting it into use the body of MM Motor Controller will become a little bit hot of which phenomenon is normal INSTALLATION AND OPERATION Put the in wall MM Motor Controller into a wall box and connect the AC power wire L N to MM Motor Controller connector L N Connect the wall switch to the MM Motor Controller as shown in picture above It is important to carry out a shutter calibration process before you control the shutter to move Press inclusion button over 3 seconds and release before the 6th second the roller shutter controller will start the shutter calibration process The process is composed of three continue stages The shutter move to the TOP in first stage and move to the BOTTOM in second stage and move to the TOP again in third sta
11. S GROUPS INTRODUCTION ASSOCIATION COMMAND CLASS VERSION 1 There is only one group called Group1 there is only one node for Group1 which support MULTILEVEL_SWITCH_REPORT METER_ REPORT_COMMAND_V3 ALARM_REPORT Report the shutter position Every time when user press S1 or S2 and let shutter to move MM Motor Controller will report the position status to controller and at the moving process when change over 10 MM Motor Controller will send Multilevel Switch Report to Group 1 also Multilevel Switch Report Ex Report position at 30 Command Class Multilevel Switch Multilevel Switch Report Value 30 Meter Command Class The Switch will report its 1 instant Power Consumption Watt or 2 accumulated power consumption KWH or 3 AC load Voltage V or 4 AC load current 1 5 load power factor PF to Z Wave Controller after receive the Meter Get Command from Z Wave Controller When the power consumption of load vary over 5 it will send Meter report to the nodes of Group as well Instant Power Consumption Watt of Switch When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x02 W Meter Report Command Command Class Meter Meter Report scale bit 2 Rate Type Meter Type Precision Scale bit 1 0 Size Meter Value 1 Meter Value 2 Meter Value 3 Meter Value 4 Rate Type 0x01 Example Meter Type 0x01 Meter Value 1
12. ch Report Value OxERIMOP BINARY_SWITCH_SET MM Motor Controller can only accept Binary Switch Set Command which value is either 0x00 Bottom or Top OxFF other value is not acceptable Command Class Binary Switch Binary Switch Set Value OxFF 255 control the shutter to the top OxFF But if the shutter is on the way down this command will stop the shutter Command Class Binary Switch Binary Switch Set Value 0x00 0 control the shutter to the bottom 0x00 But if the shutter is on the way up this command will stop the shutter MULTILEVEL SWITCH COMMAND CLASS VERSION 3 MULTILEVEL SWITCH SET MM Motor Controller can accept Multilevel Switch Set make your home smart Command Class Multilevel Switch Multilevel Switch Start eee Up Down 0x00 control the shutter to the top OxFF Command Class Multilevel Switch Multilevel Switch Start Level Change Up Down 0x01 control the shutter to the bottom 0x00 Command Class Multilevel Switch Multilevel Switch Start Level Change Up Down 0x03 Don t move the shutter or stop the moving shutter ATT Ignore_Start_Level Start_Level Dimming Duration Inc Dec Step_size can not be used MM Motor Controller can not control the speed of motor It may have some distance error caused by motor start up time If user found the error become significant you may using S1 or S2 move shutter to the end or remote move shutter to 0 and 100 and that will au
13. chnology to extend the number of switching Slim design easy install Max load up to 1100W After calibration the controller can feedback the roller shutter position Overload protection Z Wave V6 02 Very low Electricity consumption meet Europe year 2012 energy related products requirement directive 2009 125 EC no 1275 2008 Z Wave Certificated No ZC08 13070030 ZC08 13080002 LVD EN 60669 2 1 2004 A1 2009 A12 2010 EN 60669 2 2 2006 EN 60669 1 1999 A1 2002 A2 2008 1S1 2009 R amp TTE EN 301489 EN 300200 make your home smart APPLICATION IN WALL SWITCH 2 RELAY 1A AND 1C TYPE L 251 al i Relay 1C type COM Relay 1A type SPECIFICATION POWER NO LOAD STANDBY POWER 0 48W 230V 0 35W 120V INPUT VOLTAGE 110 230VAC RF REGULATION FCC part15 249 EN300 220 1 DISTANCE min 40m indoor min 100m outdoor MECHANICAL WEIGHT DIMENSION W x Hx D 30g 47 9x39x15 6 mm ENVIRONMENT OPERATION TEMPERATURE HUMIDITY 0 40 C 85 RH max LOAD RESISTIVE LOAD 1100W 230V 600W 120V OVERLOAD 1200W 230V 700W 120V www zipato com 01 There are 1 group Group 1 for using Z Wave command class user can set a threshold watt to Command which value is either 0x00 Bottom or Top 0x63 or the MM Motor Controller get the warning caused by abnormal operation OxFF or 0x01 0x62 the position between TOP and Bottom e eats bialleesed ay
14. d No part of this manual may be reproduced or transmitted in any form without the expressed written permission of Tri plus grupa d o o www zipato com 04
15. d the user s authority to operate the equipment Ke THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence Lexploitation est autoris e aux deux conditions suivantes 1 Uappareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lec trique subi m me si le brouillage est susceptible d en comprom ettre le fonctionnement NOTE Changes or modifications not expressly approved by Zipato for compliance could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio o
16. eplaced part or product The replacement product need not be new or of an identical make model or part ZIPATO may in its discretion replace the defective product or any part thereof with any reconditioned equivalent or superior product in all material respects to the defective product WARRANTOR Tri plus grupa d o o Banjavciceva 11 10 000 Zagreb CROATIA TEL 385 0 1 4004 404 FAX 385 0 1 4004 405 DECLARATION OF CONFORMITY The Manufacturer Tri plus grupa d o o hereby declares that the product Zipabox Smart home controller 1 d In accordance with the following Directivels 2006 95 EC The Low Voltage Directive 89 336 EEC The Electromagnetic Compatibility Directive and 1999 5 EC R amp TT EC Directive is in conformity with the e applicable requirements of the following documents EN 61326 EN 61000 3 3 EN 61000 4 4 EN 61000 4 11 IEC EN 55011 EN 61000 6 2 EN 61000 4 5 EN 301 489 1 3 EN 300 220 2 EN 61000 4 2 EN 61000 4 6 AS NZS IEC 60335 2 97 EN 61000 3 2 EN 61000 4 3 EN 61000 4 8 EN 60335 1 hereby declare that the equipment named above has been designed to comply with the relevant sections of the above referenced specifications The unit complies with all applicable Essential Requirements of the Directives make your home smart Person responsible for this declaration Dean Janacek Certification Manager 01 09 2012 Changes or modifications not expressly approved Tri plus grupa d o o for compliance could voi
17. ewe eanmaller meen MM Motor Controller have overload protection function and can Other value 0x64 0xFE is not acceptable inclusion Excluding a node ID allocated by Z Wave Controller help to prevent short circuit caused by load everything under control means exclusion Command Class Multilevel Switch Multilevel Switch Set Failed or success in including excluding the node ID can be Value 0x63 or OxFF 255 control the shutter to the top OxFF viewed from the Z Wave Controller PROGRAM M N G Command Class Multilevel Switch Multilevel Switch Set M C R O M O D U L E Value 0x00 0 control the shutter to the bottom 0x00 MOTO R CO NTRO LER LED INDICATION BASIC COMMAND CLASS Command Class Multilevel Switch Multilevel Switch Set The MM Motor Controller will respond to BASIC and BINARY Value 0x01 0x62 control the shutter to the position between commands that are part of the Z Wave system Borom anei op QUICK INSTALLATION GUIDE BASIC_GET v1 3 State Type LED Indication When MM Motor Controller receive Basic Get MULTILEVEL SWITCH GET Command it will send Basic Report Command to report the When MM Motor Controller receive Multilevel Switch No matter up or down close or open Led will ADDING TO Z WAVE NETWORK flash every second while Motor activate When S1 or S2 close to L the LED will flash even when the motor stop by itself this is to let user know Motor activa
18. ge Then MM Motor Controller will know the total range of UP and DOWN During the shutter calibration process any emergencies happen you can press and release the include button to stop the process If user found the direction is reverse this may cause by the wrong connection of NC and NO to the motor please change NC and NO connection and execute calibration process again For safe issue please select the motor which can stop by itself when go to bottom end or top end To manually switch up and down of the shutter simply press the external switch S1 or S2 The detail is described in Z Wave configuration section External switch type of this manual MM Motor Controller built in meter function and can read the Watt KWh V Voltage I Current PF Power Factor of the load by www zipato com BINARY_SWITCH_GET When MM Motor Controller receive Binary Switch Get Command it will send Binary Switch Report Command to report the position of the shutter When the report value is 0x00 that mean the Shutter is bottom down if the report value is OxFF that mean the Shutter is at the top But if report value is OxFE means the position is unknown Binary Switch Get Command Command Class Binary Switch Binary Switch Get Binary Switch Report Command Command Class Binary Switch Binary Switch Report Value 0x00 BOTTOM Command Class Binary Switch Binary Switch Report Value OxFE UNKNOWN Command Class Binary Switch Binary Swit
19. imited Product Warranty Period set forth below Limited Product Warranty Period if the product is used and serviced in accordance with the user manual and other documentation provided to the purchaser at the time of purchase or as amended from time to time ZIPATO does not warrant that the products will operate uninterrupted or error free or that all deficiencies errors defects or non conformities will be corrected This warranty shall not apply to problems resulting from a unauthorized alterations or attachments b negligence abuse or misuse including failure to operate the product in accordance with specifications or interface requirements c improper handling d failure of goods or services not obtained from ZIPATO or not subject to a then effective ZIPATO warranty or maintenance agreement e improper use or storage or f fire water acts of God or other catastrophic events This warranty shall also not apply to any particular product if any ZIPATO serial number has been removed or defaced in any way ZIPATO IS NOT RESPONSIBLE FOR DAMAGE THAT OCCURS AS A RESULT OF YOUR FAILURE TO FOLLOW THE INSTRUCTIONS FOR THE ZIPATO HARDWARE PRODUCT LIMITED PRODUCT WARRANTY PERIOD The Limited Product Warranty Period starts on the date of purchase from ZIPATO Your dated sales or delivery receipt www zipato com showing the date of purchase of the product is your proof of the purchase date You may be required to pr
20. ither be manipulated nor damaged TAKE CARE OF YOUR SAFETY Display extreme caution when using ladders or steps please follow manufacturer s instructions Be careful when using hand and power tools and follow the manufacturer s guidelines when using them Take care that the correct tools are used Wear goggles or protective clothing where required DANGER RISK OF ELECTROCUTION All work on the device should only be carried out by trained and skilled electricians Observe the country specific regulations CAUTION The connected devices and the flush mounted receiver can become damaged if devices are operated that do not correspond to the technical specifications see technical data DANGER RISK OF FATAL INJURY FROM ELECTRIC CURRENT The device has no basic insulation and must therefore be installed in a way that protects against accidental contact DANGER RISK OF FATAL INJURY FROM ELECTRIC CURRENT When installing a wall plate the distance between the cover s fixing brackets or screws and the connections of the flush mounted MicroModule Motor Controller must be at least 4 mm once installed If the distance is less than 4 mm a deeper installation box must be used The fixing brackets or screws of the cover must not press against the housing Only insulated tools may be used for operation on the device e g an insulated phase tester make your home smart FIGURE 1 Dimensions unit mm INCLUDE_BUTTON
21. node of correspond Group The maximum interval to report its Accumulated Power Consumption KW h is 227 55 days 10min 32767 1440 227 55 days Default value 1 hour Threshold of Watt for Load Caution This is a warning when the wattage of load over the preset threshold value If the setting value is 1100 when the load wattage over this value MM Motor Controller will send Watt Meter Report command to the node of correspond Group Default value 1100W Threshold of KWh for Load Caution This is a warning when the KWh of load over the preset threshold value If the setting value is 10000 when the Accumulated Power Consumption of Relay1 or Relay2 over this value MM Motor Controller will send KWh Meter Report command to the node of correspond Group minimum value is 1KWh and default value is 10000 kWh Level Report mode Mode 1 In 5 seconds period after controlled by a moving command it will report the destination level when received request command Out of the 5 seconds period it will report the actual level of the shutter when received Mode 2 Whenever the shutter move pass a 10 percent level it will auto report the level to Group 1 node Unit Default Description os 720 9 720s 3600s 1 hour 10min 6 6 10min 1 hour 1watt 1100 1KWh 10000 1 1 One Push button 2 Two Push button 1 1 Report destination level in 5s 2 Report 10 percent level while running www zipato com 03 L zipato everything under control
22. otor Controller receive any control moving command from Z Wave RF it will report alarm to Group1 Command_Class_Alarm Alarm_Report Alarm Type 0x01 Alarm Level OxFF S1 or S2 close to L Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0x00 Normal Configuration Size Parameter oon Bytes 1 Watt Meter Report Period 2 0x01 0x7FFF 2 KWH Meter Report Period 2 0x01 0x7FFF 3 Threshold of Watt for Load Caution 2 10 1100 4 Threshold of KWH for Load Caution 2 1 10000 5 External switch type 1 1 2 6 Level report mode 1 1 2 make your home smart Value COMMAND CLASSES COMMAND_CLASS_SWITCH_BINARY COMMAND_CLASS_ BASIC COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_VERSION COMMAND_CLASS_ ASSOCIATION COMMAND_CLASS_METER_V3 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_SWITCH_MULTILEVEL_V3 COMMAND_CLASS_ALARM COMMAND_CLASS_SCENE_ACTIVATION COMMAND_CLASS_SCENE_ACTUATOR_CONF Z WAVE S CONFIGURATION Watt Meter Report Period If the setting is configured for 1hour set value 720 the MM Motor Controller will report its instant power consumption every 1 hour to the node of correspond Group The maximum interval to report its instant power consumption Is 45 hours 5s 32767 3600 45hr Default value is 1 hour KWH Meter Report Period If the setting is configured for 1hour set value 6 the MM Motor Controller will report its Accumulated Power Consumption KW h every 1 hour to the
23. ovide proof of purchase as a condition of receiving warranty service You are entitled to warranty service according to the terms and conditions of this document if a repair to your ZIPATO branded hardware is required within the Limited Product Warranty Period Other than in respect of products for domestic use in particular those listed in the first and last boxes in the table below this Limited Product Warranty extends only to the original end user purchaser of this ZIPATO Hardware Product and is not transferable to anyone who obtains ownership of the ZIPATO Hardware Product from the original end user purchaser PRODUCT WARRANTY PERIOD TABLE PRODUCT TYPE Micromodule Motor Controller PRODUCT WARRANTY E PERIOD y IMPORTANT The content of Product Type listed above is subject to change please refer to the www zipato com for latest update PERFORMANCE OF THE LIMITED PRODUCT WARRANTY If a product defect occurs ZIPATO s sole obligation shall be to repair or replace any defective Zipato Hardware Product free of charge provided it is returned to an Authorized ZIPATO Service Centre during the Limited Warranty Period Such repair or replacement will be rendered by ZIPATO at an Authorized ZIPATO Service Centre All component parts or hardware products that are replaced under this Limited Product Warranty become the property of ZIPATO The replacement part or product takes on the remaining Limited Warranty Period of the r
24. r television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help DISPOSING AND RECYCLING YOUR PRODUCT A E This symbol on the product or packaging means that according to local laws and regulations needs to be disposed of separately from household waste and sent to recycling because it contains electronic components and a battery Once this product has reached the end of its life please take it to a collection point recycle facilites designated by your local authorities some will accept your product for free or simply drop it off at your Zipato re seller store By recycling the product and its packaging in this manner you help to conserve the environment and protect human health At Zipato we understand and are committed to reducing any impact our operations and products may have on the environment To minimize this impact Zipato designs and builds its products to be as environmentally friendly as possible by using recyclable low toxic materials in both products and packaging COPYRIGHT 2014 Tri plus grupa d o o All Rights Reserve
25. ssigned a node ID and cannot work with Z Wave Bere e Aina on and off Between BOTTOM and TOP Multilevel Switch Report Commandll enabled devices ea Class Basic Basic Report Value 0x63 0xFF Command Class Multilevel Switch Multilevel Switch Report a When overload state occurs the MM Motor Value 0x00 BOTTOM Controller is disabled and LED flashes on and Command Class Multilevel Switch Multilevel Switch Report AUTO INCLUSION off alternately at 0 5 second intervals MM Motor PAIC Sel Value 0x01 0x62 Between BOTTOM and TOP The function of auto inclusion will be executed as long as the MM Controller will send Command Class Multilevel Switch Multilevel Switch Report MM Motor Controller can accept Basic Set Command Motor Controller does not have Node ID and just connect the MM ovanor alarm_type 8 alarm_Level 0xFF to Group1 which value is either 0x00 Bottom or Top 0x63 0xFF or 0x01 Value 0x63 0xFF TOP Motor Controller to main power Overload state can be cleared by disconnect 0x62 the position between TOP and Bottom Other value 0x64 Note Auto inclusion timeout is 4 minute during which the node ce a re oror Conio ter uo ake OxFE is not acceptable MULTILEVEL SWITCH START LEVEL CHANGE information of explorer frame will be emitted once every 5 This is the command which user can move the shutter up to the seconds Unlike inclusion function as shown in the table below Command Class
26. te the S1 or S2 still close and not been release yet position of the shutter When the report value is 0x00 that mean the shutter is at the Bottom if the report value is 0x63 or OxFF that mean the shutter is at the Top any other value between 0x01 0x62 imply Shutter at the position between top and bottom Get Command it will send Multilevel Switch Report Command to report the position of the shutter When the report value is 0x00 that mean the shutter is at the Bottom if the report value is 0x63 or OxFF that mean the shutter is at the top any other Under normal operation when the MM Motor In the front casing there is an include button with LED indicator Controller has not been allocated a node ID the below which is used to carry out inclusion exclusion reset or association When first power is applied its LED flashes on and off alternately and repeatedly at 2 second intervals It implies that value between 0x01 0x62 imply shutter at the position between top and bottom Basic Get Command Command Class Basic Basic Get LED flashes on and off alternately at 2 second No nade lB intervals By pressing 51 S2 or Include button Basic Report Command Sarea MNE E CE ee ee OE ey ee eictel Command Class Basic Basic Report Value 0x00 BOTTOM Command Class Multilevel Switch Multilevel Switch Get Isconnect and reconnect the power o Command Class Basic Basic Report Value 0x01 0x62 it has not been a
27. tomatically calibrate this error Multilevel switch stop level change When receive Multilevel Switch Stop Level change Command MM Motor Controller will stop the motor SCENE ACTIVATION COMMAND CLASS Scene Activation Set Command When MM Motor Controller receive Scene Activation Set command it will read the level of the pre configured Scene ID from EEPROM And it will be controlled as a Multilevel Switch Set command The Dimming Duration of the command will be ignored because MM Motor Controller can not control the speed of motor www zipato com 02 everything under control MICROMODULE MOTOR CONTROLLER QUICK re a GUIDE v1 SCENE ACTUATOR CONFIGURATION COMMAND CLASS Command Class Scene Actuator Configuration Scene Actuator Configuration Set Scene ID 1 255 Override bit 0 Level 0 99 or 255 The current setting of MM Motor Controller will not be override Command Class Scene Actuator Configuration Scene Actuator Configuration Set Scene ID 1 255 Override bit 1 Level 0 99 or 255 The Level value in this Command is associated to the Scene ID Scene Actuator Configuration Set Command Command Class Scene Actuator Configuration Scene Actuator Configuration Get Scene ID 1 255 Command Class Scene Actuator Configuration Scene Actuator Configuration Report Scene ID 1 255 Level 0 99 or 255 Dimming Duration 0 OxFE Report the Pre configured Scene ID of MM Motor Controller Z WAVE