1. loop wires do not short to the reed switch or antenna The contact loop must use closed circuit devices The loop response time is a nominal 100mSec NOTE If the contact loop is not to be used no connection is needed across the loop terminals BATTERY INSTALLATION REPLACEMENT SPECIFICATIONS 1 Remove the transmitter s cover if it is not already Dimensions 1 1 2 W x 3 H x 7 8 D off as described in MOUNTING Step 1 88mm x 76mm x 22mm 2 Observe correct polarity and insert the battery Battery 3V Lithium see Note in step 2 of BATTERY provided into the battery holder see Fig 2 Take INSTALLATION REPLACEMENT care not to bend the antenna ease nthe nena A NOTE Replace battery only with BATTERY CAUTION Risk of fire Panasonic CR123A Duracell DL123A or explosion and burns Do not recharge disas ADEMCO 466 i semble heat above 212 F 100 C or in 3 To replace the cover engage the hooks along one cinerate DISpose pr Used Batteries promptly Keep away from children edge and snap shut eS Cae a etc ee TO THE INSTALLER Regular maintenance and inspection at least annually by the installer and frequent testing by the user are vital to continuous satisfactory operation of any alarm system The installer should assume the responsibility of developing and offering a regular maintenance program to the user as well as acquainting the user with the proper operation and limitations of the alarm system and its compon
2. 1 and pressing it against the locking tab also shown in Figure 1 while sliding the mounting plate upward along the case back until free 3 Install the mounting plate with its two case holding posts pointing up in this example in the location selected as described in the control panel s installation instructions Use the flat head screws supplied Note lf a wired contact loop is to be used with concealed wiring the wire exit hole in the wall must be located under the wire entry hole in the case as shown in Figure 2 and no more than 1 4 in diameter 4 lf a wired contact loop is to be used feed concealed wiring through the slot in the case back but do not connect to the terminal block yet For surface wiring entry two thin breakout areas are provided in the case wall See Figure 1 5 Attach the case back to the mounting plate by sliding the keyhole slots in the case back down onto the mounting plate s case holding posts The locking tab will click as the case back locks in place 6 If a reed switch is to be used mount a No 5899 Magnet obtained separately adjacent to the reed switch or adjacent to the top of the case see Figure 2 In either case the magnet must be mounted within one half inch of the reed switch LOOP WIRING CONNECTIONS lf used With the battery still not inserted connect the contact loop wires to the unit s loop terminals see Figure 2 Caution Make sure that the bared sections of the
3. Honeywell LOCKING TAB WIRE A ISauIM je J POST 2 U MOUNTING A K5503V2 4 08 Rev B ADEMCO 5815 DOOR WINDOW TRANSMITTER COVER PRY OFF SLOT LOCKING TAB RELEASE WINDOW COVER RETAINING HOOKS HOLES 2 3 5815 01 VO MOUNTING PLATE CASE Figure 1 Mounting Plate and Case GENERAL INFORMATION The Honeywell Ademco 5815 is a two zone Door Window Transmitter that has its own unique serial number The control unit is required to enroll the serial number prior to its usage in the alarm system Refer to the control unit s installation instructions for further details Note During programming of the control unit 5815 transmitters should be treated as RF i e supervised RF Type mandatory for UL installations The 5815 provides two input loops zones the first for a wired closed circuit contact loop and the second for its built in reed switch used in conjunction with a magnet as described below One or both inputs may be used For UL installations a contact may not be more than 3 feet from the transmitter The 5815 includes a built in cover tamper which is activated when the cover is removed MOUNTING For proper orientation of the unit in relation to the mounting plate loop wiring and or magnet read all of this section before installing the unit The description that follows assumes that the unit will be mounted as shown in the d
4. ent parts Recommendations must be included for a specific program of frequent testing at least weekly to insure the system s operation at all times REFER TO THE INSTALLATION INSTRUCTIONS FOR THE RECEIVER CONTROL WITH WHICH THIS DEVICE IS USED FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM FCC IC STATEMENT This device complies with Part 15 of the FCC Rules and RSS210 of Industry Canada Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FEDERAL COMMYNICATIONS COMMISSION STATEMENT The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User s Manual Unauthorized changes or modifications could void the user s authority to operate the equipment For the latest warranty information please go to http www security honeywell com hsc resources wa index html Honeywell 2 Corporate Center Drive Suite 100 P O Box 9040 Melville NY 11747 Copyright 2008 Honeywell International Inc http www honeywell com security K5503V2 4 08 Rev B
5. iagrams with the magnet if used located in one of the positions shown in Figure 2 The unit may however be installed in any direction as long as the relationship of the unit to its mounting plate and if used magnet is maintained Although the unit can be mounted directly to a surface we recommend that the mounting plate be used for ease in removing the unit for servicing should it become necessary Before mounting the transmitter permanently conduct Go No Go tests see control s instructions to verify adequate signal strength and reorient or relocate the transmitter if necessary 1 Remove the transmitter s top cover by inserting the flat blade of a small screwdriver into the pry off slot at one end of the unit see Fig 1 for location and slightly twisting the blade until the cover disengages IMPORTANT DO NOT REMOVE the circuit board from the back case plastic INSTALLATION INSTRUCTIONS ALTERNATE POSITION COVER FOR MAGNET REED PRY OFF LO STH ais i LOOP 2 WIRE ENTRY _ HOLE S LOOP TERMINALS GA LOOP 1 TAMPER SWITCH ANNTENNA av MAGNET gt OBTAIN i SEPARATELY z IC 5 o E Ja oO REED 2 CRYSTAL SWITCH LOOP 2 HOOKS 3 MAGNET MUST BE WITHIN 1 2 OF REED SWITCH 5815 002 VO Figure 2 5815 shown without cover 2 Disengage the attached mounting plate from the case by inserting the blade of a small screwdriver into the locking tab release window see Figure
Download Pdf Manuals
Related Search
Related Contents
LG 55LH55 55" Full HD Black LCD TV Wiko 304285 4GB Black smartphone 96-Well Ras Activation ELISA Kit (Chemiluminescent) Thule TBC411G Nokia 3710 fold User Guide Roadstar HRA-1100 Copyright © All rights reserved.
Failed to retrieve file