Home

user manual - Victron Energy

image

Contents

1. 315 7 9 11 1al15l17 2 17 2 4 6 8 10 12 14 16 18 20 Starter battery positive connection sii Starter battery negative connection Illustration 9 Starter battery con nections screwdriver no 0 potentiometer Nailpolish Illustration 11 Potentiometers My victron energie user manual C 23 24 user manual C My victron energie 5 START UP yo gt 5 1 Operation The switches and LEDs of the inverter are located on the front of the Atlas Combi see illustration 12 inverter description on switched on auto automatic AES load on inverter inverter switched to the output overload overload indication high battery high input voltage low battery low input voltage temperature temperature indication charger description on switched on load on mains load switched at input float charging voltage for checking the battery equalize boost charging voltage once battery are fully charged failure charger not functioning properly INVERTER CHARGER OQ on O on O auto load on inv on O SEH on overload E off Anes B oa ion bar MM 0 equalize ES off low batt temperature failure Illustration 12 Atlas Combi 12 800 frontpanel My victron energie user manual 25 5 2 On position Start the inverter by setting the inverter sw
2. a K x 7 EEE HDR4 HDR5 lt q HDR6 gt E Jumpers connected not connected 4 uur equalize loadingtime 8 uur equalize loadingtime diode splittervoltage traktion loadingvoltage normal loadingsettings temperature compensation HDR 3 pin 1 2 left HDR 3 pin 2 3 right HDR 5 HDR 1 2 3 pin 1 2 4 6 HDR 4 HDR 5 HDR 6 Note HDR 1 and 2 are for test and adjustment purposes only and should always be connected Remove frontplate first Victron Energie Victron Atlas Combi 12 800 jumper settings drawingno ACO4013E date 230694 revisionno 0001 44 user manual My victron energie
3. 230 Vac 47 63 Hz 10 1 x 10 amp slow 5 x 20 mm 0 7 inductive D Nominal charging voltage 12 Vpc Boost charging voltage 14 25 Vpc Float charging voltage 13 5 Vpc Charging characteristic IUoUo according to DIN 41772 Voltage stability 1 Output current 30 amp Trickle charge fuse 15 Amp car fuse 36 user manual C Myy victron energie 7 2 3 Changeover Maximum switching capacity Changeover time Changeover delay Protective device 7 3 General EMC 2300 Watt 0 1 sec ca 10 seconds ceramic fuse 10 amp slow 5 x 20 mm Electro magnetic compatability according Council Directive 89 336 EEC Emission Immunity 74 Mechanical data Noise level Cabinet Protection Colour Dimensions H x W x D Weight Connecting points Output Output input 12 Vac Trickle charger Input Earth Cooling Relative humidity EN 55014 1993 EN 60555 2 1986 EN 50082 1 1991 40 dB A Aluminium resistant to seawater IP21 Blue RAL 5012 epoxy 350 x 250 x 213 mm 16 5 kg 230 Vac terminals 2 5 mm M8 screws 230 Vac terminals 2 5 mm M4 screw Natural cooling 95 maximum My victron energie user manual CE 37 38 user manual C My victron energie 8 DRAWINGS Complete Victron Energy System Atlas Combi 12 800 cabinet dimensions Remote control connections Atlas Combi 12 800 connections Position jumpers Atlas Combi 12 800 3
4. My victron energie 2 PROTECTIVE DEVICES short circuit current current supplied when a short circuit on the out put occurs LED Light Emitting Diode The Atlas Combi is extremely reliable thanks to numerous built in protective devices Descriptions of these devices are given below 2 1 Short circuits With the Atlas Combi 12 800 inverter output which is protected against short circuiting amounts to 2 75 amp In this condition the output voltage approaches O V Once the short circuit has been rectified the inverter immediately resumes normal operation This eliminates the need to fit a fuse in the inverter s output circuit 2 2 Maximum power There is an upper limit to the power which the inverter can deliver This level which is limited electronically can be delivered for 3 seconds continuous power maximum power Atlas Combi 12 800 800 Watt 1500 Watt 2 3 Overload If the inverter is subjected to a high load it may reach the critical limit approx 1000 Watt and the overload protection will be activated The overload protective device fitted to the Atlas Combi 12 800 works as follows A If the critical limit is reached the red overload LED lights up After 3 seconds the inverter limits the power to ca 1000 Watt Oo If the load drops below the critical limit within 3 seconds the inverter continues working normally and the overload LED goes out O When af
5. off The problem has been solved if after this period the 12 V batteries have values of about 14 25 V If the values are lower go to step 4 step 4 Check whether too many pieces of external equipment are connected to the Atlas Combi and check the batteries for Cl defective cell s O a maximum capacity of 300 a h O If the batteries are in proper working order go to step 6 Any battery ies not meeting the specifications must be replaced After replacement go to step 5 step 5 Check the charger again The problem has been solved if the charger works properly If it does not go to step 6 step 6 Contact your Victron dealer to have the Atlas Combi repaired step 7 Check the mains supply or generator supply for the correct voltage drops of voltage in lines excessively long cables etc If necessary consult the manufacturer of the item s concerned 34 user manual C Myy victron energie 7 SPECIFICATIONS 71 Inverter 7 1 1 Input Nominal input voltage Input voltage range Switch on voltage Switch off voltage Voltage ripple Nominal input current Maximum input current No load in auto mode No load in on mode Input fuses 7 1 2 Output Output voltage Frequency Waveform of output voltage Power factor Power at 20 C Power at 30 C Switch on behaviour 12 Vpc 10 17 25 Vpc 11 Vpc 10 Vpc maximum 5 RMS 80 amp 150 amp 2 Watt 7 5 Watt 4 x 30
6. on LED inverter auto LED inverter overload LED inverter high battery LED inverter low battery LED inverter temperature 10 ground 11 switch charger on 12 LED charger on o 13 LED charger equalize boost AR 14 LED charger failure 15 ext current control 1 16 ext current control 2 17 temperature sensor 18 temperature sensor 19 start battery 20 start battery starter battery connections temperature sensor connections current control 22k lin amp on off switch inverter LED s amp on auto off switch J J A charger LEDs gt Victron Energie Victron Atlas Combi 12 800 remote control connections drawing no ACO4012E date 230694 revision no 0001 42 user manual C My victron energie 230 V Output 230 V Input Remote control connection Negative battery connection Positive battery connection Victron Energie Victron Atlas Combi 12 800 connections drawingno AC04014E date 230694 revisionno 0001 My victron energie user manual C 43 HDR3 HDR1 HDR2
7. 5 3 5 4 5 5 Operation On position Auto position Changeover 5 4 1 Engaging 230 V mains 5 4 2 Disengaging 230 V mains Charger Ovo E ANADAN UI My victron energie user manual 5 6 Adjustments 24 5 6 1 Frequency 24 5 6 2 Output voltage 24 5 6 3 Switch on sensitivity on auto 24 5 7 Battery charger 24 5 7 1 Maximum charging current 24 5 7 2 Adjustment of voltage 24 5 7 3 Float 25 5 7 4 Equalize 26 5 8 Maintenance 26 6 FAULT TRACING LIST 27 6 1 General 27 6 2 The inverter fails to start 27 6 3 The AC output voltage is too low 28 6 4 The battery charger does not start 29 6 5 The batteries overcharge 29 6 6 The batteries do not charge fully 30 Te SPECIFICATIONS 33 7 1 Inverter 33 7 1 1 Input 33 7 1 2 Output 33 7 1 3 Automatic Economy Switch AES 33 7 2 Battery charger 34 7 2 1 Input 34 7 2 2 Output 34 7 2 3 Changeover 34 7 3 General 39 7 4 Mechanical data 35 8 DRAWINGS 37 Complete energy system 38 Atlas Combi cabinet dimensions 39 Remote control connections 40 Atlas Combi connections 41 Position jumpers Atlas Combi 42 10 user manual C Myy victron energie 1 DESCRIPTION 1P21 protection against materials larger than 12 mm for example a finger and protection against vertically descending water Watt unit of power Volt unit of voltage Voltrms root mean square effective value of alternating wave Hertz unit of frequency 1 1 General Victron Atl
8. 8 39 40 41 42 My victron energie user manual Mains Manager Y v net e o Fa ch victron energie lt lt bn starter batteries ATLAS COMBI va engine Victron Atlas Combi 1 u Mm v fe CC LR t service batteries gt gt lt lt EEE p 5 I 220 V generator am 12 V dc on board e systeem Victron washing machine micro wave ighting i S e drawingno ACO4010E O victron energie b v complete 12 Volt Victron Energie system with Atlas Combi alate 220098 40 user manual My victron energie 200 205 25 e 25 e lt lt 8 31 gle S 2 3 en N L r 8 0 mm D Ki o 8 lt 230 e drawii ACO4015E victron energie b v Victron Atlas Combi 12 800 dimensions ri date 230694 My victron energie user manual CEE 41 2 4 1 31517 9 11 13 15 17 19 6 8 10 12 14 16 18 20 LO AO UI VIV ground switch inverter on switch inverter auto LED inverter
9. Amp carfuse 230 Vac 5 50 Hz 1 Hz Trapezoidal 0 9 capacitive to 0 4 inductive 800 Watt power factor 1 700 Watt power factor 1 The inverter can start under any load conditions The nominal output voltage is reached in 50 msec 7 1 3 Automatic Economy Switch AES Switch on Adjustable sensitivity Switch off Test voltage on auto Efficiency Dynamic stability 9 5 Watt 2 48 Watt 4 5 Watt 65 Vrms 50 Hz 91 maximum Maximum surges of 10 when switching on and off at 50 nominal load Recovery time is 1 2 period My victron energie user manual CE 35 Overload protection Short circuit protection Ambient temperature protection High low input voltage protection 7 2 Battery charger 7 2 1 Input Nominal input voltage Frequency Input voltage range Input voltage fuse 230 240 V Power factor 7 2 2 Output The delivered power is limited electronically to 185 12 Volt battery of the continuous power at the nominal input voltage The output is short circuit proof The short circuit current is 2 75 Arms Sensors measure the temperature of critical components The sensors switch off the inverter if the temperature on the FETs rises above 75 C and or the transformer temperature rises above 140 C The inverter restarts automatically after the components have cooled down The inverter switches off automatically at values above 17 25 Vpc and below 10 Vpc
10. If it becomes defective again go to step 4 step 4 Contact your Victron Energie dealer to have the Atlas Combi repaired 6 5 The batteries overcharge step 1 Check the battery voltage when the equalize LED lights up Go to step 2 step 2 If the battery voltage is about 14 25 V ona 12 V battery ies contact the manufacturer of the battery because the battery is probably defective If so the battery ies must be replaced If the voltage is higher than the above values go to step 3 step 3 Check the jumpers on the charger PCB They are located to the left on the inside of the door For normal usage jumpers HDR 1 2 4 and 6 are switched on jumper HDR 5 is switched off and HDR 3 is in the left hand position see section 8 drawing number AC04013E on page 42 If this is the case go to step 4 My victron energie user manual 33 step 4 Contact your Victron dealer to have the Atlas Combi repaired 6 6 The batteries do not charge fully step 1 Check whether the cables to the batteries are properly connected to the cable terminals Repair these connections if the contacts are defective If this does not solve the problem go to step 2 step 2 Check the mains voltage at the input of the Atlas Combi If it is higher than 200 VAC go to step 3 If it is lower than 200 Vac go to section 6 3 step 3 Allow the Atlas Combi to charge continuously for about eight hours with the 12 V external equipment switched
11. able for countless situations in the field on ships or other places where a mobile 230 Volt AC power supply is indispensable Victron Energie has the ideal power source for all kinds of electrical appliances used for household technical and administrative purposes including instruments susceptible to interference All of these applications require a high quality power supply in order to function properly Victron Atlas Combi 12 800 This manual contains directions for installing the Atlas Combi model 12 800 It describes the functionality and operation of the Atlas Combi including its protective devices and other technical features My victron energie user manual 7 user manual C Myy victron energie CONTENTS DESCRIPTION General Victron Atlas Combi The battery charging section The inverter section Changeover Charging PROTECTIVE DEVICES Short circuits Maximum power Overload Temperature Low input voltage High input voltage COMPENSATED CHARGING 3 1 32 3 3 3 4 Connection of temperature sensor Battery temperatures of up to 10 C Battery temperatures between 10 C and 50 C High battery temperature INSTALLATION 4 1 4 2 4 3 44 4 5 4 6 4 7 Materials required for 230 V connections Location Battery cables Connections 4 4 1 Earth 44 2 230 Vac output 44 3 230 Vac input 4 4 4 Battery Starter battery Jumpers general Potentiometers general START UP 5 1 5 2
12. arefully the instructions which are given in section 4 3 16 user manual Myy victron energie 3 COMPENSATED CHARGING V T S Victron Temperature Sensor The Atlas Combi has a temperature compensation facility which adjusts the charger voltage to the battery temperature In order to use this facility a temperature sensor V T S must be fitted to the battery This is because a higher charging voltage can be used with a cold battery than with a warm battery The reference charging voltage is 14 25 V at a battery temperature of 20 C see illustration 4 34 Connection of temperature sensor In order to connect the temperature sensor jumper HDR6 must first be switched off position 0 see Drawings section drawing no ACO4013E page 42 The temperature sensor is operating when its yellow LED is lit up for information on jumpers see section 4 6 Jumpers general 3 2 Battery temperatures of up to 10 C At temperatures of up to 10 C the charger supplies a maximum charging voltage of 14 5 V This output voltage is limited because at higher voltages problems might occur in the external equipment see illustration 4 section A 3 3 Battery temperatures between 10 C and 50 C In this temperature range the output voltage is dependent on battery temperature as measured by the sensor As the temperature increases the output voltage of the charger decreases by 30 mV C 5 mV C per ce
13. as Combi 12 800 units are tested to ensure correct functioning before leaving the factory They are packed in shock absorbing polystyrene and packed in sturdy cardboard boxes for secure transportation The Victron Atlas Combi is housed in a robust aluminium cabinet IP21 suitable for floor or wall mounting The AC output terminals the DC battery terminals and the terminals for a remote control panel can be reached by opening the front of the cabinet with a screwdriver 1 2 Victron Atlas Combi The Atlas Combi is a compact combination of an inverter and an automatic battery charger hence the name Atlas Combi The coding of the Combi models is composed as follows example Atlas Combi 12 800 12 12 Volt battery voltage 800 800 Watt continuous power My victron energie user manual 11 The Atlas Combi delivers a trapezoidal alternating current of 230 V 50 Hz Continuous power can be delivered at all times A maximum short duration power can be delivered for about three seconds Almost any electric or electronic device powered by a 230 VAC 50 Hz supply may be connected to the inverter of the Atlas Combi 1 3 The battery charging section The battery charger of the Atlas Combi is suitable for a 230 V 50 Hz mains voltage The charger works automatically and delivers a maximum current of The batteries may remain permanently connected to the charger even during winter storage The A
14. ing either on a wall or on a horizontal surface Ensure that there is adequate ventilation to allow for natural cooling The front of the Atlas Combi is detachable Make sure you will have easy access to the inside of the unit from the front after installation a Keep the distance between the Atlas Combi and the battery ies as short as possible 4 3 Battery cables The wire diameters of the battery cables are suitable for continuous loads and peak loads Distances to the battery ies cable diameter less than 1 5 m 25 mm more than 2 5 m but less than 4 0 m 35 mm more than 4 0 m but less than 6 0 m 50 mm Avoid contact resistances by tightening up all connections My victron energie user manual 19 4 4 Connections 4 4 1 Earth Connect the mains earth wire to the earth terminal of the AC terminal block The circuit is functional only if the cabinet is connected to earth An M4 earth screw is fitted in the bottom of the cabinet Connect the cabinet earth terminal to earth The earth for vessels is the hull or earth plate for motor vehicles it is the chassis 4 4 2 230 VAC output The terminal block is located on the PCB The 230 V external equipment must be connected to the inverter by means of a three wire cable see illustration 7 Use a cable with a flexible core and a wire diameter of 1 5 mm to 2 5 mm The connection arrangement of the output terminal block is Phase Brow
15. itch to the on position The LEDs on and load on inverter light up if an output voltage is present 5 3 Auto position When the inverter is in the auto mode bottom position of the switch the yellow auto LED and the load on inverter LED light up to indicate that the AES has been activated Refer to the fault tracing list if this does not occur The inverter starts as soon as the load at the output exceeds 9 Watt The yellow auto LED goes out and the green on LED lights up The inverter switches back to the auto mode automatically as soon as the load is switched off The yellow auto LED lights up again 5 4 Changeover 5 4 1 Engaging 230 V mains If the inverter is connected to the 230 V mains the following sequence of events will occur 1 After about 10 seconds the load is switched from the inverter to the mains network The yellow load on mains LED lights up 2 The inverter switches off All LEDs go out 3 The battery charger starts to operate 4 The on LED lights up 5 The equalize boost LED lights up 6 The charging capacity of the charger reaches a maximum about 5 seconds after the equalize boost LED lights up 5 4 2 Disengaging 230 V mains If the 230 V mains voltage is switched off the following sequence of events will occur 1 The load is switched to the inverter 2 The inverter starts immediately The load on inverte
16. ll See illustration 4 section B My victron energie user manual 17 3 4 High battery temperature At battery temperatures of 50 C and above the charging voltage drops sharply At values of 55 C and above the charger operates as a rectifier with an output voltage of 12 V see illustrations 4 and 5 sections C and D The plastic bag containing connection materials includes instructions showing where the temperature sensor must be fitted It is also necessary to change jumper HRD6 on the control PCB see section Drawings drawing number AC04013E page 42 12 V qc A gt e B lafe Volt V 20 10 0 10 20 30 40 50 temp C Illustration 4 Temperature com pensation while loading 18 user manual C Myy victron energie 4 INSTALLATION 4 1 Materials required for 230 V connections Two mains leads 1 5 mm maximum length 6 m Screwdriver No 1 to connect the 230 V cables Open end spanner M8 IO 4 2 Location a Install the inverter in a dry area with good ventilation NOTE High ambient temperatures will reduce output power impair efficiency and shorten working life see SPECIFICATIONS a There are holes in the bottom and rear of the cabinet for floor or wall mounting For the dimensions refer to section 8 Drawings drawing number AC04015E page 39 a The Atlas Combi is suitable for mount
17. lustration 13 Location of potentiometers on print My victron energie user manual 29 5 7 4 Equalize The high charging voltage is adjustable by means of potentiometer R3 farthest left Switch on the charger Wait until the batteries are charged to a level where the charging current is below 5 amp The yellow equalize boost LED should now light up Connect a voltmeter with a reading accuracy of at least 0 1 V to the output of the charger Turn potentiometer R3 until the correct voltage is set Seal the adjusting screw of potentiometer R3 with nail polish or Tipp Ex 5 8 Maintenance The Atlas Combi does not require any special maintenance It is advisable to check the electrical connections periodically once a year Keep the converter as dry and clean as possible 30 user manual C My victron energie 6 FAULT TRACING LIST Sa The following tables will facilitate the rapid tracing of the most common types of faults 6 1 General For the checks to be carried out on the charger Oo Connect the mains supply to the charger o Disconnect all 12 V external equipment from the batteries The fault tracing tables assume the following phenomena the inverter does not start the AC output voltage is too low the charger does not start The battery ies overcharge The battery ies do not charge fully 00000 6 2 The inverter fails to start step 1 Set the inverter switch to
18. ly charged or recharged but the inverter does not start step 7 Check whether the plus and minus of the battery ies and the Atlas Combi correspond Go to step 8 step 8 Contact your Victron Energie dealer to have the Atlas Combi repaired 6 3 The AC output voltage is too low step If you have determined with an RMS voltmeter moving iron voltmeter that the AC output voltage is too low go to step 2 step 2 Turn potentiometer P2 see section 5 Adjustments to the right and check whether the voltage returns to the normal value If it does not go to step 3 step 3 Contact your Victron dealer to have the Atlas Combi repaired 32 user manual C Myy victron energie 6 4 The battery charger does not start step 1 Turn on the charger by setting the charger switch to the on position If the on equalize boost and current amps LEDs light up proceed to section 6 6 If the LEDs of the battery charging section fail to light up go to step 2 step 2 Turn off the 230 V mains supply Check the ceramic fuse F7 This is located on the charger PCB in the cabinet In addition use a voltmeter to check whether the input voltage exceeds 200 Volt If the fuse is intact go to step 4 If the fuse is defective proceed to step 3 step 3 Replace the defective fuse Reconnect the 230 V mains supply to the Atlas Combi The problem has been solved if the fuse operates normally
19. n or Black wire to L1 Neutral Blue wire to N Earth Yellow Green wire to PE 4 4 3 230 VAC input A 230 VAC supply is needed if the Atlas Combi s battery charger is used Use a three wire cable with a wire diameter of 1 5 to 2 5 mm2 The connection arrangement of the input terminal block is in the same order as the output terminal block see illustration 8 Underside Atlas Combi Earth connection M4 Illustration 5 H H bes C Wen E N PE Illustration 6 Output vltage con nections alala san ER L Illustration 7 Input voltage connec tions The inverter will be damaged if another alternating current e g from a generator is connected to the 230 V output 20 user manual C Myy victron energie output terminal block output delivery 230 Volt input terminal block input acceptance 230 Volt remote connec tions connections for remote control 4 4 4 Battery The functioning and working life of equipment and batteries depend on the battery connections being made correctly Between the battery and the Atlas Combi there is a circuit with a lll Negative battery connector ol Positive battery connector Illustration 8 Battery connections l
20. ow voltage and high current Resistance decreases accordingly as cables become apen A shorter and thicker The combined resistance of the two cables must not exceed 4 milliohms As previously explained in section 2 6 the inverter is not protected against reversed polarity The following procedure should therefore be used step 1 Unscrew the four screws on the front of the cabinet 1 step 2 Carefully slide the front of the cabinet to one side step 3 Satisfy yourself that the four fuses 30 ampere have been disconnected You will find the fuses with the other connection material Connect up the battery cables the red to the right hand connector and the to the connector on the left If the connections have been made properly the green LED right will light up My victron energie user manual CE 21 step 4 If the red LED wrong lights up this means that the battery cables have been wrongly connected In this event immediately disconnect the battery cables Switch the cables over then reconnect them battery e cee step 5 When the green LED right is lit up the four 30 ampere fuses can be fitted To this end disconnect the M EI plus pole of the battery cable Fit the fuses then Mm reconnect the plus pole again step 6 Check that the connections have been sufficiently tightened Use the M8 o
21. pen end spanner 4 5 Starter battery Connect the starter battery to terminals 19 and 20 of the remote terminal blocks 19 is the and 20 is the of the battery A wire thickness of 1 5 mm is sufficient for double pole connecting up this battery switching switching by means of a relay which has two Ensure that all switching between different 230 Vac GE power supplies e g shore generator takes place and one for the by means of DOUBLE POLE switches Otherwise neutra wie the Atlas Combi may be damaged 4 6 Jumpers general uu Jumpers are small removable connectors Jumper situated on the PCB By placing and removing the jumpers various features can be v enabled or disabled 1 Illustration 10 shows how to set the jumpers Slide jumper over both pins to put jumper ON Slide over only one pin to set jumper OFF Illustration 10 Jumpers 22 user manual C Myy victron energie 4 7 Potentiometers general Potentiometers are adjustable resistors Turning the screw increases or reduces the values associated within the potentiometer These values may concern matters such as voltage frequency or switch on sensitivity The screw must be turned by means of a screwdriver No 0 and sealed with Tipp Ex or nail polish see illustration 11 00000000090 ARAAARAAAAAR 00000000090
22. quipment has switched on 5 7 Battery charger 5 7 1 Maximum charging current The maximum charging current has been set to 30 amp by means of potentiometer P6 the one farthest to the right Measure this with a separate current meter Switch on the charger and apply a load that creates an output voltage of 12 V Turn potentiometer P6 until the correct current has been set Seal the adjusting screw of potentiometer P6 with nail polish or Tipp Ex 5 7 2 Adjustment of voltage The battery charger operates with two charging voltages which must be adjusted separately First set the low charging voltage float and then the high charging voltage equalize 28 user manual C Myy victron energie 5 7 3 Float The low charging voltage is adjustable by means of potentiometer P4 the one on the left Switch on the charger and disconnect all external equipment Wait until recharging has finished and the yellow equalize boost LED has gone out Connect a voltmeter with a reading accuracy of at least 0 1 V to the output of the charger Turn potentiometer R4 until the correct voltage is set Seal the adjusting screw of potentiometer R4 with nail polish or Tipp Ex P5 auto sensitivity P6 charging current _ P4 charger P1 inverter P2 Inverter float voltage frequentie Output voltage d Ex P3 charger gt ME HM x equalize Ez z inverter charger S Il
23. quires more than 30 amp A new boost equalize float cycle is also started if the charger is switched off briefly With the VDL system the battery can remain permanently connected to the battery charger without overcharging gassing My victron energie user manual 27 5 6 Adjustments Open the cabinet by unscrewing the four outer screws on the front which is then removed The adjustment points are on the control PCB of the inverter The PCB has six adjustment points see illustration 13 5 6 1 Frequency The frequency is set to a standard value of 50 Hz although this can be altered by turning potentiometer P1 to the left or to the right This can be measured with a digital frequency meter Please note that analog frequency meters often give incorrect readings 5 6 2 Output voltage The output voltage is set to a standard value of 225 Vrms at a load of continuous power and an input voltage of 12 V The unloaded output voltage is approximately 232 Vrms The output voltage may be adjusted by turning potentiometer P2 top right to the left or to the right 5 6 3 Switch on sensitivity on auto Tf the inverter fails to start when the external equipment requests power the AES sensitivity may be increased by unscrewing the front PCB and turning potentiometer P5 in the centre of the PCB to the right Check whether the inverter returns to auto once the external e
24. r and on LEDs light up 3 The external equipment is reconnected to a 230 V supply within 1 second 4 The load on mains LED goes out and the battery charger is switched off 26 user manual C Myy victron energie V D L Victron trickle charge system float charge mode recharging boost charge mode initial charging 5 5 Charger The charger of the Atlas Combi is switched on by setting the charger switch to the on position The on and equalize boost LEDs then light up The charging current starts to rise a few seconds after the on and equalize boost LEDs light up The voltage rises gradually depending on battery capacity discharge and consumption When the battery reaches a voltage of 14 25 V the charging current drops This high charging current is maintained for four or eight hours producing optimum recharging of the batteries After this period the charger switches to a lower voltage of 13 5 V The equalize boost LED is now off The battery charger works with the VDL 2 step charging system made by Victron Energie It automatically keeps the battery in a perfectly charged condition for extended periods External equipment has immediate access to power If during the float charge cycle the voltage drops below 13 5 V for longer than 30 seconds a new boost charge cycle is started This may occur after the switching on of external equipment which re
25. tage has been switched to the output 1 5 Changeover When a mains voltage Illustration 1 No load output volt is connected to the age during on mode Atlas Combi the inverter is automatically switched to mains after about 10 seconds This changeover is indicated by the yellow load on mains LED the load on inverter LED goes out and the inverter is intermittent immediately switched load off More information alba regnan about this changeover is switched on and E i off automatically given in section 5 4 in equipment such ES MERE or Illustration 2 No load output voltage electric heaters L MU ATC ELE during auto mode My victron energie user manual 13 1 6 Charging The automatic part of the charger starts up about 5 seconds after the charger switch has been set to the on position and 230 VAC is present Charging takes place according to the IUoUo characteristic see illustration 2 12 V battery voltage The charging current reaches a maximum at a battery voltage of 12 V see section 1 3 The standard settings for boost charging voltage and float charging voltage are 14 25 V and 13 5 V respectively 12 Vdc 13 57 gt time T np mi boost equalize float boost equalize time AC Alternating Current DC Direct Current 14 user manual
26. ter 3 seconds the inverter has reached the limit of its capacity and the load then drops below the My victron energie user manual 15 critical limit another 3 seconds must elapse before the inverter again delivers full power O Tf the inverter is overloaded for too long the thermal protection device will switch off the inverter after a few minutes 2 4 Temperature The temperature of the electronics is measured continuously The inverter switches off before the temperature reaches an unacceptably high level due to short circuiting overloading or excessive ambient temperatures The red temperature LED lights up when this situation occurs The inverter restarts automatically once the temperature has dropped to an acceptable level input voltage DC voltage delivered by batteries 2 5 Low input voltage output voltage AC voltage i delivered by the The inverter switches off if the input voltage is too low This Victron Product input voltage limit is 10 V The inverter restarts when this voltage exceeds 11 V 2 6 High input voltage The inverter switches off if the input voltage is too high The inverter switches off if the input voltage rises above 17 3 V and restarts once the input voltage has dropped below 16 3 V The Atlas Combi 12 800 is NOT protected against reversed polarity i e connected to and connected to Accordingly please follow c
27. the on position and check whether the green on LED lights up Go to step 2 step 2 The following may occur The green on LED lights up and the Atlas Combi produces only a buzzing noise go to step 3 O The green on LED lights up and the overload LED lights up after a few seconds go to step 3 O The green on LED lights up and the battery low LED lights up go to step 4 O The green on LED does not light up go to step 8 step 3 Remove the load from the AC output and check whether the overload LED goes out when the inverter is switched on If 1t does not go to step 8 My victron energie user manual 31 step 4 Check the input voltage of the battery ies on the terminals of the Atlas Combi The input voltage of a 12 Volt battery should lie between the following two values min input voltage 11 Volt max input voltage 16 Volt If the input voltage is not between the minimum and maximum values go to step 5 If the input voltage is correct go to step 7 step 5 Check whether the 12 V connecting cables are properly connected and the wires are of a sufficient diameter Rectify the situation if the connecting cables are not properly connected or the wire diameters are not in conformity with the specifications If this action does not solve the problem go to step 6 step 6 The batteries must be charged Go to step 7 if the batteries have been sufficient
28. tlas Combi is suitable for starter batteries and semi traction batteries of the lead acid type in open or sealed designs A starter battery may be connected to the second charger output This charger can charge a starter battery with a maximum current of 4 amp starter battery 1 4 The inverter section a battery used only to start machines such as The inverter converts a direct current of 12 V into an the engine of a alternating current of 230 V 50 Hz With the Atlas Combi SERION d Suitable switched on i e switch set to on the inverter s own currents no load power consumption per model is semitraction battery A full load efficiency of approximately 91 is achieved through the use of FET transistors see illustration 1 The Atlas Combi has a stand by facility as standard It is activated by setting the switch to the auto position This switches the inverter to a lower stand by voltage at times when the external equipment does not require power This limits power consumption to 2 Watt and the inverter operates PCB when a load is detected Substantially reduced power Printed Circuit consumption is achieved when there are intermittent loads Board The sensitivity of the AES Automatic Economy Switch can be adjusted for more information see section 5 Start up 12 user manual C Myy victron energie The inverter is furnished with a Load on inverter LED This indicates that the inverter vol
29. victron energie My g USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas Combi 12 800 My victron energie Subject to change without notice AC04001E 271095 2 user manual C Myy victron energie SECTIONS ENGLISH 1 NEDERLANDS 43 DEUTSCH 87 My victron energie user manual user manual C Myy victron energie ENGLISH USER MANUAL Victron Atlas Combi 12 800 M victron energie user manual 5 user manual C Myy victron energie INTRODUCTION A Victron Energie has established an international reputation as a leading designer and manufacturer of power systems Our R amp D department is the driving force behind this reputation as it is continually seeking new ways of incorporating the latest technology in our products Each step forward results in value adding technical and economical features Our proven philosophy has resulted in a full range of state of the art equipment for the supply of electrical power that meets the most stringent requirements Victron Energie systems provide you with high quality AC supplies in places where there are no permanent sources of 230 Volt AC power An automatic stand alone power system can be created with a configuration comprising a Victron Energie inverter battery charger mains manager if required and last but not least batteries with sufficient capacity Our equipment is suit