image

Contents

1. The shape and position of the switches and indicators may vary from different models but their function are simiar If there is any difference between the sketch map and the substantiality please subject to the substantiality 3 Remote Control The remote control transmits signals to the system ON OFF button f S ransmitting display Used to start and stop operation aa Time setting display Transmits signals to the system c Temperature setting display i 2 TIMER button D A setting temperature adjustment display Used to select TIMER operation W During feel mode uP button TOO COOL button A Used to increase the set room temperature 60 F 88 F and time 0 5 24h DOWN button TOO WARM button V Used to decrease the set room temperature and time SLEEP button J Used to set or cancel sleep operation ee It includes normal SLEEP Jand Comfort Q E e e able SLEEP but Comfortable SLEEP is optional Ct UL gt a en swing SWING control button Used to adjust airflow direction oo MODE a e T A FAN SPEED control button Y Eco lia Used to select the indoor fan motor speed Auto or High Qor Q gt ON OFF e 6 6 Le lt o Mid or and Low or D This function k invalid in sleep A MODE button Used to select the type of operation mode FEELV COOLING ae DRY FAN S AND
2. Krimaire SPLIT AIR CONDITIONER OWNERS MANUAL Thank you for selecting super quality Air Conditioner To ensure satisfactory operation for many years tocome this Owner s Manual should be read carefully be fore using your air conditioner Afterre ading st ore it in a safe place P lease refer to the manual for questions onuseorin the event that any irregularities occur This Air Conditioner should be used for household use CONTENTS Safety PPOCAUUONS escccarsereciainrsersiemacecannarouanmsnesenaades 1 Identification OF Parts scscass tenes scnscdiassstions ines stioaddtnadstiqneveanitozededantnenes 2 Remote Controller Sains cela aaa bat lace adc acetate hae ae 4 Operation INStrUCtIONS ccccccccceeesesssssenneeeeeeeeeesseessnseneeeeeeeeees 7 MaintenanCe asx sssrinin nA E Ekaa 9 PRrotectiomisscinintiniiniontinimin ARE 10 TROUDISSINO OURO csceniscentcecceccssaccnsicatctceteecedeecaleedeccetattetecceteieeateet 11 Installation IMSEUCUOMS sascccgisscticcetincctennsGeancdbeccRencedeeneteensdeaactianess 12 Preparation Before Use Before using the air conditioner be sure to check and pre set the following Remote Controller Pre setting The remote controller is NOT preset as Cooling Only Air Conditioner or Heat Pump by manufacturer Each time after the remote Controller replaces of batteries or is energized the symbol will flash from Cool and HEAT alternatively User can preset the remote controller type
3. 19 Kimairex The Klimaire logo is a registered Trademark of Klimaire Products inc Copyright 2010 Klimaire Products Inc 2190 NW 89 Place Doral FL 33172 USA Tel 305 594 4972 Fax 305 675 2212 www klimaire com sales klimaire com
4. Ineffective control e f strong interference from excessive static electricity discharge power supply voltage abnormality presents operation will be abnormal At this time disconnect from the power supply and connect back 2 3 seconds later Does not operate immediately Changing mode during operation 3 minutes will delay Peculiar odor This odor may come from another source such as furniture cigarette etc which is sucked in the unit and blows out with the air A sound of flowing water Caused by the flow of refrigerant in the air conditioner not a problem Defrosting sound in heating mode Cracking sound is heard The sound may be generated by the expansion or contraction of the front panel due to change of temperature Spray mist from the outlet Mist appears when the room air becomes very cold because of cool air discharged from indoor unit during COOLING or DRY operation mode The compressor indicator red lights on constantly and indoor fan stops e The unit is shifting from heating mode to defrost The indicator will lights go off within ten minutes and returns to heating mode Air will not immediately e The air condotioner is ready to blow out enough warm air please wait 2 5 minutes blow out at the start of HEAT mode Stop discharging airflow for 5 10minutes 3 e The appliance will defrost automatically and mist appears from outdoor After defrosting it co
5. 2 way and 3 way valve e Connect the pipes to the 2 way and 3 way valves separately according to the required torque 4 Outdoor Unit Cable Connection see previous page The air which contains moisture remaining in the refrigeration cycle may cause a malfunction on the compressor After connecting the indoor and outdoor units evacuate air and moisture from refrigerant cycle using a vacuum pump as shown below Vacuum pump 3 way valve diagram connect to indoor unit 6 Open 1 4 turn 7 Turn to fully open the valve 7 Turn to fully open the S vale valve cap as ta 1 Turn O PE ee 1 Turn 8 Tighten 2 Turn Valve ca i p 8 Tighten T needle 8 Tighten Ex Connect to outdoor unit l Valve core service port cap open position spindle Note To protect the environment be sure not to discharge the refrigerant to the air directly 17 Installation Instructions lt interconnection Cable 1 Take off the cover for Interconnection cable of outdoor unit 2 Take off the block for Interconnection cable then put the core of the power wire to the terminal and fix it according to the diagrams pasted to indoor and outdoor unit separately 3 Fix the accessory cable with the Interconnection cable block 4 Confirm the fixing of the accessory cable is ok 5 Fix the cover for Interconnection cable on Diagram for installation of Interconnection cable please see the pasted d
6. HEATING 2 Only for Heat Pump FEEL mode can select the operation mode such as COOL DRY FAN HEAT automatically depending on the room temperature and the feel mode is default setting at starting SUPER button optional 4 Used to start and stop SUPER operation 0 ECO button optional amp Used to start and stop ECONOMY operation This function is invalid in SUPER mode The indoor fan motor speed is AUTO mode fan speed in ECO Mode HEALTHY button optional r Used to start and stop HEALTHY operation DISPLAY button optional Used to start and stop DISPLAY screen operation amp ANTI MILDEW button optional Used to start and stop ANTI MILDEW operation 3D button optional 7 Used to start and stop 3D operation Two direction Airflow the horizontal louver is opened different direction in different mode optional Note Each mode and relevant function will be further specified in following pages SRS Remote Control Remote Control gt Some remote control display Feel Cool Dry Fan Heat AE ES A 6 amp s ge age v LILI hO v OI hO VOSIL LEEDI Auto Low Mid High Sleep Swing Note The above remote controller is only for reference please refer to your own for details When inserting the batteries for the first time or each time the batteries are replaced as they are discharged the remote control mades a short Auto Test all the symbols can be displayed are
7. depending on the air conditioner type you have purchased as follows Press any button when the heating symbol flashes then Heat Pump is set Press any button when the cooling symbol flashes then Cooling Only is set If you dont press any button within 10 seconds the remote controller is pre set as Heat Pump automatically Note If the air conditioner you purchased is a Cooling Only one but you pre set the remote controller as Heat Pump it doesn t bring any matter But if the air conditioner you purchased is a Heat Pump one and you preset the remote control as Cooling Only then you CAN NOT preset the Heating operation with the remote controller Auto restart Pre setting optional the appliance is preset as Auto restart function by manufacturer If Auto restart function is not needed follow the steps below to cancel this function 1 Make sure the air con s power is off 2 Press and hold the Emergency button ON OFF on the indoor unit until then electrify 3 Keep pressing the Emergency button for more than 10 seconds until four short beeps are heard Then Auto restart function is disabled To activate the Auto restart function repeat above procedure until three short beeps are heard This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely Young children should be supervised to ensure that th
8. is invalid in SUPER mode too Switches OFF the appliance automatically after 10 hours in Normal SLEEP mode 2 Normal SLEEP only after the Unit t s start Select the operating mode and then press SLEEP button the indoor fan speed operates at low speed Switches OFF the appliance automatically after 8 hours Cox lt A Note After setting the timer check that TIMER INDICATOR lamp of A NS an Comfortable SLEEP note In this model the temperature will automatically be adjusted with the body tempreature like the english letter V at the first stage of sleep the body tempreature will decrease when our air conditioner s set temperature decrease together and at the last stage of sleep the body tempreature will increase when our air conditioner s set temperature increase together it is very comfortable for people s sleeping Maintenance panel maintenance power supply Air filter maintenance It is necessary to clean the air filter after using it for about 100 hours Clean it as follows Grasp position a and pull outward to remove the front panel Wipe with a soft and dry cloth Use lukewarm water below fag 2522 57 2 85 F to clean if the NS clean it fee appliance is very dirty Stop the appliance and remove the air filter NEN 1 Open the front panel 2 Press the handle of the filter gently from the front 3 Grasp the handle and slide out the filter Never use
9. reaching a vacuum of 10 mm Hg absolutes 5 With vacuum pump still running close the low pressure knob on vacuum pump manifold Then stop vacuum pump 6 Open 2 way valve 1 4 turn then close it after 10 seconds Check tightness of all joints using liquid soap or an electronic leak detector 7 Turn 2 and 3 way valves stem to fully the valves Disconnect vacuum pump flexible hose 8 Replace and tighten all valve caps e Connect to the power source check if the function selection keys on the remote controller are working properly eCheck if the room temperature adjustments and timer settings are working properly eCheck if the drain is smooth eCheck if there is any abnormal noise or vibration during operation eCheck if there is leakage of refrigerant ATTENTION If there is no power plug along with the air conditioner The power cord should be connected to an air switch whose current carrying capacity should be more than 20A and the minimum open circuit distance among the live polar pole the neutral polar pole and the ground polar pole should be more than 3mm If any malfuctions please cut off the supply by the air switch and contact the manufacturer or its service agent The appliance shall be installed in accordance with national wiring regulations If the supply cord is damaged It is better to be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard ort e Please re
10. shown on the screen and keep 2 seconds then the symbol will flash from Cool and HEAT alternatively For cooling only air con please press any button when the cooling symbol is flashing the the remote control has been set as cooling only For cooling and heating air con please press any button when the heating symbol is flashing then the remote controller has been set as cooling and heating If none of the button is pressed within 10 seconds the remote control will be set as cooling and heating automatically Cooling only air con can use the remote control which has cooling and heating function but do not have the function of heating Although the air con is not running remote control still have some display The light of the remote control will be turned on by pressing any button for 1 5 3 seconds and it will be turned off automatically if no button is pressed within 10 seconds Remote Control How to Insert the Batteries Please slide and remove the cover Remove the battery cover according to the arrow direction Insert new batteries making sure that the and of Slide the cover battery are matched correctly ESS upwardly in the irection ol e Re attach the cover by sliding it back into position S arrow Note Exchange the batteries Use 2 LR03 AAA 1 5volt batteries Do not use s rechargeable batteries Replace batteries with new PEA ones of the same type when the display becomes dim Storage and Tips for Usin
11. stop the appliance in the cases listed below Install the air conditioner at a place that Outdoor air temperature is over 75 F can bear its weight in order to operate more quietly HEATING Outdoor air temperature is below 20 F 5 F for inverter models it s optional e Install the outdoor unit at a place where Room temperature is over 80 F the air discharged and the operation noise would not annoy your neighbors Outdoor air temperature is over 110 F COOLING or below Ot for inverter models Do not place any obstacles in front of the Room temperature is below 70 F air outlet of the outdoor unit lest it increases DRY Room temperature is below 65 F the noise level For Tropical T3 Climate condition models the temperature point is 126 F instead of 110 F If the air conditioner runs in COOLING or DRY mode with door or window opened for a long time when relative humidity is above 80 dew may drip down from the outlet Features of protector Inspection 1 The protective device will work as follows After using for long time the air conditioner should be inspected on the following items Restarting the unit at once after operation Overheatofth dani stops or changing mode during operation you per a pene pa al y cole ena Pug need towait a minutes Abnormal operating sound or vibration e Water leakage from indoor unit Connect to power supply and turn on i h as the uni
12. volatile substance such as gasoline or polishing powder to clean the appliance Never sprinkle water onto the indoor unit Clean and re install the air filter If the dirt is conspicuous wash it with a solution of detergent in lukewarm water After cleaning dry well in shade Reinstall and shut the gt front panel Reinstall and shut the front panel by pressing position b downward At the end of the season Set temperature to 86 F for about half a day and perform the Cooling operation to dry well the Unit s inside Dry the inside of the unit a Stop the unit operation and then f turn off the power switch for safety ffon and for saving electric energy Sk Close the front panel again Clean the air filter every two weeks if the air conditioner operates in an extremely dusty environment At the beginning of the season Make sure there are no obstacles blocking the airflow around the air intake and air outlet openings of the Indoor and Outdoor Clean and reinstall the air filters O Clean both Indoor and Outdoor Units Make sure the earth wire is not broken or disconnected O vae sure the air filters are cleaned rerove batteries from the remote controller Quen on the power switch Qrrser batteries into the remote controller Protection Operating condition Noise pollution The protective device maybe trip and
13. Installing Indoor Unit Where there is no obstacle near the air outlet and air can be easily blown to every corner Where piping and wall hole can be easily arranged Keep the required space from the unit to the ceiling and wall e according to the wiring diagram e Where the air filter can be easily removed Keep the unit and remote controller 1m or more apart from e television radio etc e Keep as far as possible away from fluorescent lamps Do not put anything near the air inlet to obstruct it from air absorption Where there is strong enough to bear the weight and is not tend to increase operation noise and vibration Location for Installing Outdoor Unit e Where it is convenient to install and well ventilated avoid installing it where flammable gas could leak Keep the required distance apart from the wall Keep the outdoor unit away from a place of greasy dirt vulcanization gas exit or high salty seashore Avoid installing it at the roadside where there is a risk of e Muddy water e A fixed base so as not to increasing operation noise Where there is no blockage for air outlet Front panel Terminal inside COVER B side after connect A side before connecti Cabinet Installation Diagram Indoor unit Pipe length is 49 feet Max utdoor unit be less than 16 ft Height should Outdoor unit Pipe length is 49 feet Max Height should be less t
14. ad this manual before installing and using it e Do not let air enter the refrigeration system or discharge refrigerant when moving the air conditioner e Testing run the air conditioner after finishing installation and record details of operation e Type of fuse used on indoor unit controller for 9K 12K 18K 24K is 50T with rating 3 15 A 250V Type of fuse used on inverter outdoor unit controller for 7K 9K 12K is 61T with rating 15 A 250V for 18K 24K is 65TS with rating 25A 250V e The fuse for the whole unit is to be provided by the user according to the current at maximum power input or use other over current protective device instead e Accessibility to the plug must be guaranteed even after the installation of the appliance to disconnect it in case of need If not possible connect appliance to a double pole switching device with contact separation of at least 1 8 in placed in an accessible position even after installation Please make replacing with the special assembly purchasing from our factory or our service center if something wrong with Interconnection cable e The security out static air pressure for our products is 0 8 1 05 standard pressure The biggest length for our connection pipe can be 49 ft More 20 g refrigerant is necessary for per miter if the length is over 23 ft The biggest diversity for altitude between indoor and outdoor unit is 16 ft Please do not place valuable things under the unit after installation
15. ature will increase 4 F the indicator will not change When the w button is pushed the temperature will reduce 2 F After temperature reduce 4 F_ the indicator will not change The operation of the AUTO mode canbe performed by only pressing the ON OFF button from the next time There will be a delay when changing mode is made during the operation As there might not be air blown out e If you don t like the content of FEEL mode operation change to HEATING DRY or COOLING than FEEL Operation Instructions It is convenient to set the timer on with TIMER button when you go out in the morning to achieve a comfortable room temperature when you get home You can also set timer off at night to enjoy a good sleep Timer setting ff When the Remote When the Remote Controller is OFF press i Controller is ON press the TIMER button to set the TIMER button to a switch on timer press set a switch on timer again the setting willbe MEE press again the setting cancel will be cancel HEALTHY DISPLAY 3D nr ILDEW Press UP and DOWN button to set time Time setting is 30 minutes swine the indoor unit lights D ECO super 1 Normal SLEEP amp Comfortable SLEEP optional Have press the SLEEP button for 3 seconds SLEEP operation is switched from Normal SLEEP to Comfortable SLEEP alternatively Used to set or cancel sleep operation This function is invalid in fan and dehumidify mode This function
16. drains at COOLING or DRY operation Qutdoor Uni The figures in this manual are based on the external view of a standard model Consequently the shape may differ from that of the air conditioner you have selected Identification of Parts Display of environm ental temperature or setting temperature It lights up when power supply is on Display of environm Display of environm ental temperature or setting temperature ental temperature or setting temperature It lights up when power supply is o It lights up during the setsleep function Itis on during operation Please check your fan coil unit appearance and refer to the Please check your fan coil unit appearance and refer instructions that apply to that unit to the instructions that apply to that unit Used to control the unit when the remote controller is out of work Please check your fan coil unit appearance and refer to the corresponding diagram ON FF 4 Used to control the unit when the remote controller is out of work Please check your fan coil unit POWER SLEEP TIMER RUN appearance and refer to the corresponding diagram Remarks When remote controlleris out ofwork open the paneland you cansee emergency button there see the above pictures The emergency button for 18K and 24K series is at the top right seeON OFF button there
17. ey do not play with the appliance Safety Precautions Symbols in this Use and Care Manual are interpreted as shown below Q Be sure to follow this instruction S Be sure not to do Pay attention to such a situation Grounding is essential A e Remove the power source plug from a socket Warning Incorrect handling could cause a serious hazard such as death serious injury etc A Use correct power supply in accordance with the rating plate requirement Otherwise serious faults or hazard may occur or a fire maybe break out If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Keep the power supply ff circuit breaker or plug from dirt Connect the ON A power supply cord to it firmly and correctly lest SS an electric shock or a fire break out due to insufficient contact may occur Do not use the power supply circuit breaker or pull off the plug to turn it off during operation This may cause a fire due to spark etc A Do not tangle pull or press the power supply cord as this cord will be damaged and an electric shock or fire is probably caused by a broken power supply cord A GN Never insert a stick or similar obstacle to the unit When the fan rotates at high speed this may cause an injury A 39 It is harmful to your health if the cool air reaches you fo
18. g the Remote Control The remote control may be stored mounted on a wall with a holder Note The remote control holder is an optional part Remote control holder d How to Use To operate the room air conditioner aim the remote control to the signal receptor The remote control will operate the air conditioner at a distance of up to 23 ft when pointing at signal receptor of indoor unit Operation Instructions lt GFEEL mode operation procedure gt Operates by selecting automatically the operation mode HEAT DRY FAN COOL depending on the room temperature during start With the remote controller pointing toward the air conditioner Turning on Press button when the appliance receives the signal the RUN indicator of the indoor unit lights up When the unit is not at FEEL mode Selecting FEEL mode Press the MODE select button Move the MODE to the FEEL position Indoor temperature Operation mode Target temperature Less than 68 F HEATING FOR HEAT PUMP TYPE FAN FOR COOL ONLY TYPE TF 68 F 79 F Over 78 F DRY COOL 64 F 73 F Air temperature adjustment is possible even during FEEL operation There are 4 levels of adjustment possible with the A button or the v button Setting temperature Press the A button or the v button When the Abutton is pushed the temperature will increase 2 F After temper
19. han 16 ft me Indoor unit 13 Installation Instructions indoor Unit Installatiom 1 Installing the Mounting Plate e Decide an installing location for the mounting plate according to the indoor unit location and piping direction e Keep the mounting plate horizontally with a horizontal ruler or dropping line e Drill holes of 1 1 4 in depth on the wall for fixing the plate e Insert the plastic plugs to the hole fix the mounting plate with tapping screws e Inspect if the mounting plate is well fixed Then drill a hole for piping Hook the line here Line drops from here holes for fixing Note The s hape of your mounting plate may be different from the one above but installation method is similar 2 Drill a Hole for Piping e Decide the position of hole for piping according to the location of mounting plate e Drill a hole on the wall The hole should tilt a little downward toward outside e Install a sleeve through the wall hole to keep the wall tidy and clean Wall hole sleeve hard polythene tube prepared by user Indoor Outdoor 13 64 in tilt downward i 3 Indoor Unit Piping Installation e Put the piping liquid and gas pipe and cables through the wall hole from outside or put them through from inside after indoor piping and cables connection complete so as to connect to outdoor unit e Decide whether saw the unloading piece off in accordance with the piping d
20. iagram instruction on the body first Circuit Diagram 09K 12K 18K indoor interconnection cable sketch map 24K indoor and outdoor interconnection cable sketch map ndoor Unit Outdoor Unit Indoor Unit Outdoor Unit T23NLE Tht LUE 0 W Connetting Connetting Connetting Connetting Connetting Connetting Cooling Only Cooling amp Heating outdoor unit indoor unit power outdoor unit indoor unit power Cooling amp Heating Cooling Only 09K 12K 18K outdoor interconnection cable sketch map Split frequency conversion air conditioner interconnection cable means Heating and cooling was as same as Cooling Indoor Unit Outdoor Unit V l i j l Cooling Only Cooling amp Heating Connetting outdoor unit Connetting indoor unit Note Some models are designed without the conneting terminal in indoor unit please subject to the connetion diagram of the product 18 Installation Instructions lt _How to Purge Air Tubes gt 1 Unscrew and remove caps from 2 and 3 way valves 2 Unscrew and remove cap from service valve 3 Connect vacuum pump flexible hose to the service valve 4 Start vacuum pump for 10 15 minutes until
21. iping is directed to the right piping power Cord and drain pipe should be thermal insulated and fixed onto the back of the unit with a piping fixer Insert here D CA oi ME I H hose N CTA Base Piping fixer Base Piping fixer Base A Insert the pipe fixer to the slot B Press to hook the pipe fixer onto the base a Piping Connection T a Connect indoor unit pipes with two wrenches Pay special attention to the allowed torque as shown below to prevent the pipes connectors and flare nuts from being deformed and damaged Hook here b Pre tighten them with fingers at first then use the wrenches Model Pipe size Torque Nut width 9 12 18K Liquid Side 6 or 1 4 inch 1 8kg m 21 32 in 24K Liquid Side 10 or 3 8 inch 3 5kg m 7 8 in 9K Gas Side 610 or 3 8 inch 3 5kg m 7 8 in 12 K for R410A Gas Side 10 or 3 8 inch 3 5kg m 7 8 in 12 18K Gas Side 12 or 1 2 inch 5 5kg m 15 16 in 24K Gas Side 16 or 5 8 inch 7 5kg m 1 1 16 in 15 Installation Instructions 4 Connecting of the Cable e Indoor Unit Connect the power connecting cord to the indoor unit by connecting the wires to the terminals on the control board individually in accordance with the outdoor unit connection Front l i pang Terminal inside Note For some models it is necessary to remove the cabinet to connect to indoor unit terminal Indoor un
22. irection as shown below Piping direction trough piece Note When installing the pipe at the directions 1 2 or 4 saw the corresponding unloading piece off the indoor unit base Saw the unloading piece off along the trough e After connecting piping as required install the drain hose Then connect the power cords After connecting wrap the piping cords and drain hose together with thermal insulation materials 14 Nore Installation Instructions Piping Joints Thermal Insulation Gg Wrap the piping joints with thermal a L insulation materials and then wrap Ea with a vinyl tape u wrapped with vinyl type The temperature of refrigerant circuit will be high please keep the Thermal insulation interconnection cable away from the copper tube Piping Thermal Insulation Large pipe Thermal insulation a Place the drain hose under the piping tube b Insulation material uses polythene foam over 6mm in thickness Power cord Note Drain hose is prepared by user Drain pipe should point downward for easy drain flow Do not arrange the drain pipe twisted sticking out or wave Power cord 1 around do not immerse the end of it in water for heat pump If an extension drain hose is connected to the drain pipe make sure to thermal insulated when passing along the indoor unit Drain hose Defrost cable for heat pump prepared by user When the p
23. it Ch ssis e Outdoor Unit 1 Remove the access door from the unit by loosening the screw Connect the wires to the terminals on the control board individually as the following 2 Secure the power connecting cord onto the control board with cable clamp 3 Reinstall the access door to the original position with the screw 4 Use a recognized circuit breaker for 24 K model between the power source and the unit A disconnecting device to adequately disconnect all supply lines must be The figures in this manual are based on the external view of a standard model fitted Consequently the shape may differ from that of the air conditioner you have selected Caution 1 Never fail to have an individual power circuit specifically for the air conditioner As for the method of wiring refer to the circuit diagram posted on the inside of the access door 2 Comfirm that the cable thickness is as specified in the power source specification See the cable specification table below 3 Check the wires and make sure that they are all tightly fastened after cable connection 4 Be sure to install an earth leakage circuit breaker in wet or moist area Cable Specifications Capacity Btu h Power cord Power connecting cord Power connecting cord1 for heat pump Type Normal cross Type Normal cross Type Normal cross sectional area sectional area sectional area 9K HOSVV F _1 0m
24. mX3 HOSRN F _1 0mmX3 HO5RN F 0 75mmk2 1 0mmx3 1 0mmxX3 z 0 75mmxK2 ae 12K HO5VV F 1 5mmX3 HO5RN F 1 5mmX3 HO5RN F F 1 5mmk3 LHOSRN F 4 i 18K HOSVV F HORNF 1 5mmxX3 HO5RN F 0 75mmX2 24K HO7RN F 2 5mmk3 HOSRN F 0 75mmX6 heat pump 0 75mmX4 cool only 28K 30K HO7RN F 4 0mmX3 HOSRN F _0 75mmx4 9K 12K HOSVV F 1 0mmx3 sna 4 0mmxk4 1 5mmx3 1 5mmX4 Inverter 18K HOSVV F 1 5mmX3 Ho7RN F 1 5mmk4 22K HOSVV F 4 5mm3 HO7RN F 1 5mmX4 HO5RN F i 24K HO7RN F 25mMmX3 HO7RN F 2 5mm 4 Note Above cables should be UL approved 16 Installation Instructions lt iutdoor Unit Installation gt 1 Install Drain Port and Drain Hose for heat pump model only The condensate drains from the outdoor unit when the unit operates in heating mode In order to protect the environment install a drain port and a drain hose to direct the condensate water Just install the drain port and rubber washer to the chassis of the outdoor unit then connect a drain hose to the port as the right figure shown Washer o Drain port amp Drain hose 2 Install and Fix Outdoor Unit prepare by user Fix with bolts and nuts tightly on a flat and strong floor If installed on the wall or roof make sure to fix the supporter well to prevent it from shaking due to serious vibration or strong wind 3 Outdoor Unit Piping Connection e Remove the valve caps from the
25. ntinues to run automatically Q during HEATING operation Geita The remote controller does not function correctly e If the distance regulate area and it have obstacled between the remote controller and the unit e Are the batteries exhausted Replace them with new ones and repeat the operation again Installation Instructions Distance from wall should be over 6 in Distance from ceiling Di should be over 6 in Ss Distance from the wall should be over 6 in Distance from floor q G f should be over 79 in j Air intake distance from the wall Air intake distance from should be over 12 in the wall should be over 12 in Above figure is only a simple presentation of the unit it may not match the external appearance of the unit you purchased Installation must be performed in accordance with the national wiring standards by authorized personnel only e Very Important Installation must done by a registered qualified installer Refer warranty section at the back of this manual 12 Installation Instructions Connecting of the Cable gt Wiring between the indoor and outdoor units 1 Remove the PCB cover from the indoor unit 2 Refer to the wiring diagram attached to indoor unit when connecting cords to indoor unit terminals 3 Reinstall the PCB cover Be sure that side B is facing outside lt Select the best location gt Location for
26. r a long period It is advisable to allow the air flow to circulate to all the wholeroom 9 Q Firstly turn off by the appliance remote controller before cutting off power supply if malfunction occurs Do not repair the appliance by yourself If this is done incorrectly it may cause an electric shock etc Prevent the air flow from reaching the gas burners and stoves Do not touch the operation buttons X when your hands are wet e Do not use extension cords and do not connect the air conditioner to a socket to which other electric appliances are connected Make sure to use a fuse of proper electric rating 4 Od Use of steel or copper wire instead of a fuse is strictly prohibited Do not put anything on the unit especially vases which contain water inside S If water gets into the unit the electrical insulation would be deteriorated because it could result in a trouble or fire accident and this could cause electric shocks Do not put any objects on the outdoor unit Check that the plug is not covered withdust and make sure to insert it firmly so that it does not get loosened Fully insert the plug firmly If the plug is coverd with dust or improperly inserted thes may cause electric shock or fire Do not wash the air conditioner with water When operation the system simultaneously with a combustion appara
27. t at once it may start 20 seconds Metal cabinet electrified 2 later Stop the air conditioner if above trouble occurs It is advisable to have a detail inspection after If all operation has stopped press ON OFF using it for 5 years even if none above occurs button again to restart Timer should be set again if it has been canceled Features of HEATING mode Preheat At the beginning of HEATING operation the airflow from indoor unit is discharged 2 5 minutes later Afterheat After the finishing of HEATING operation the airflow from indoor unit is discharged 2 5 minutes Defrost In HEATING operation the appliance will defrost de ice automatically to raise efficiency This procedure usually lasts 2 10 minutes During defrosting fans stop operation After defrosting completes it returns to HEATING mode automatically Note Heating is NOT available for cooling only air conditioner models 10 Troubleshooting The following cases may not always be a malfunction please check it before asking for service Trouble Does not run Analysis e Ifthe plug is not properly plugged e f batteries in the remote controller exhausted e f the protective device works to protect the appliance e Ifthe protector trip or fuse is blown No cooling or heating air e Are the intakes and outlets of the air conditioner blocked e Is the temperature set properly e Is the air filter dirty
28. tus you should air the room frequently Insufficient ventilation could cause an oxygen deficiency accident It is the user s responsibility to ground the appliance according to local codes or ordinances by a licenced technician Pe When not using the system for a long time remove the plug from the socket to ensure safety If the plug is covered with dust it could cause heat generation or fire If abnormal conditions occur such as smell of burning immediately stop the system operation remove the power plug and consult your Dealer Operating the system under abnormal conditions could result in malfunctions eletric shocks fire etc Before cleaning the system stop the operation and remove the Q power plug a Cleaning should never be carried out while the inside fans are running Notes For the purpose of innovation and improvement above products are subject to change without prior notice The air conditioner is not a toy please keep away from children The appliance shall not be installed in the laundry Identification of Parts Air Intake ee Front Panel Emergency Panel Display Panel L Air Outlet Vertical Adjustment Louver Horizontal Adjustment Louver Charcoal Filter optional Electrostatic Filter optional Air Filter Remote Controller Air Intake Pipes and Power Connection Cord Drain Hose Note Condensate water

Download Pdf Manuals

image

Related Search

Related Contents

Brother AX-325 Typewriter User Manual  BETRIEBSANLEITUNG - Flowserve Corporation  snail ex - Akvarista  Quel avenir pour les lentilles intraoculaires phaques ? - LASIK  Resorcell  Frigidaire FGMV153CLW Microwave Oven User Manual  VUBCB33N  Préparation à la maintenance des appareils iOS  Samsung Samsung INNOV8 Bruksanvisning  WX-1711 User Manual  