Home
PMX400 Four Digit Programmable Display with Outputs
Contents
1. Output Analogue output a Curent AO option only 5 Voltage 6 Security Link Link to allow access to PPE the set up mode nor 7 Security Link mally not connected 8 9 CJC Board white mark alligns with terminal 11 10 Thermocouple inputs 11 12 Not used 8 Not used 9 10 B RTD inputs 1 1 Bsense 12 A 8 Not used 9 10 mV input Millivolt inputs lta mV input 12 Not used 13 Normally Closed Alarm Channel One 14 Common 4RO option only 15 Normally Open 16 Normally Closed 17 Common Alarm Channel Two 4RO option only 18 Normally Open 19 Normally Closed 10 Common Alarm Channel Three 4RO option only 21 Normally Open 22 Normally Closed Alarm Channel Four 2 Gommon 4RO option only 24 Normally Open Subject to technical alterations without notice Printed in Australia e 7940015660 05 05 2009 PMX400 Series Displays PMX400HZX e Measures frequency of signals from industrial sensors e Provides power for active input devices e Two alarm channels e Debounce for contact closure inputs Options The basic software will control the optional analogue outputs and alarm channels without modification So to retrofit an option you can simply add a card calibrate and setup for your installation from the front panel Technical Data Display Scaling Inputs Type Range Sensor power output Input voltage range Power supply Type AC selectable DC Power us
2. Data Sheet e Mann Series Four Digit Programmable Displays with Alarms and Analogue Output PMX400TMP Temperature Display PMX400HZX Frequency Display Tachometer Mann Series PMX Weidmiller gt e Bright four digit LED display in engineering units e Up to 4 alarm channels e Optional analogue output e AC or DC powered e Fully Isolated e LED alarm status indication e 1 8 DIN standard front with IP65 rating e Integral power supply for active input devices e Indicate and change setpoints in engineering units e Full on site programming from the front panel keypad CE We LISTED Australia Weidm ller Pty Ltd 43 Huntingwood Drive Huntingwood NSW 2148 Phone 61 0 2 9671 9999 Fax 61 0 2 9671 9900 Info weidmuller com au www mannseries com United Kingdom Other countries Weidm ller Ltd Weidm ller Interface GmbH amp Co 1 Abbey Wood Road Kings Hill Postfach 3030 West Malling Kent ME19 4YT 32720 Detmold Phone 44 1732 877032 Phone 495231 14 0 Fax 44 1732 873873 Fax 495231 14 2083 Info weidmuller co uk info weidmueller com Ly www weidmueller com www weidmueller com el m y er PMX400 Series Displays PMX400 Series The PMxX400 series consists of two models e Temperature display e Frequency display Tachometer Each model supports a wide variety of input signal types and ranges The analogue and alarm outputs are optional except for the HZX which comes with two open collector
3. See individual units alue alue 1 to 99 Enable disable Value Value Direct or reversed Enable disable Enable disable On the fly changes or locked Manual or Automatic Normally Energised or De energised High Low and Siren Group for channel our only According to display range From 1 count to display range 0 4200s default Os E Subject to technical alterations without notice Printed in Australia e 7940015660 05 05 2009 PMX400 Series Displays PMX400TMP e Accepts thermocouple RTD or mV inputs e Total sensor diagnostics e Indicates temperature in C or F e Configure without the need to calibrate Indicates setpoints in C or F Automatic CJC for thermocouple inputs Automatic lead length compensation for RTD inputs Technical Data Display Scaling Inputs Type Standard ranges J Type Thermocouple K Type Thermocouple Type Thermocouple ype Thermocoup oO lype Thermocoup D lype Thermocoup D lype Thermocoupl o N T E B S R lype Thermocoup D mV signals RTD Pt100 Cold junction compensation for thermocouple inputs Lead length compensation for RTD inputs Power supply Type AC selectable DC Power usage Alarm ouputs all channels Type Rating Isolation General Sampling rate Options AO 4RO Notes Ordering Information Page 3 Weidmiiller 2 Universal Temperature Indicator O
4. age Alarm ouputs channels one and two Type Operation Rating isolation Alarm ouputs channels three and four Type Rating isolation General Response time Options AO RO FPS Ordering Information Page 4 Weidmiiller 2 Universal Frequency Indicator Tachometer Inputs Inputs can be taken from many sources including e NAMUR sensors e 3 wire PNP NPN sensors e PNP NPN open collector outputs e TTL logic e Solid State Switches e Low and high voltage pulses e Volt free contacts To display in engineering units Programmable frequency Any range within the limits shown Span range Zero range Resolution 0 to 9 999Hz 0 to 9 998Hz 0 001Hz 0 to 99 99Hz 0 to 99 98Hz 0 01Hz 0 to 999 9Hz 0 to 999 8Hz 0 1Hz 0 to 9999Hz 0 to 9998Hz 1Hz Nominally 12Vdc to 25 mA others on request FPS option 50mVac to 250Vac or 3Vdc to 250Vdc AC or DC powered 100 132 Vac 47 63Hz or 200 264 Vac 47 63Hz 24Vdc 10 others on request AC 6VA or 6W at 24Vdc NPN open collector transistor type Switched to OV when on to 200mA on state current or 50Vdc off state voltage Note back emf protection must be used for inductive loads Common negative rail SPDT relay contacts 3A at 240Vac resistive 3A at 24Vdc resistive 1kV between channels 220mS 10 90mS df 1 With analogue output fitted With alar
5. alarms as standard Units can be ordered with two or four SPDT relay channels Alarm channel four can be set up as a group siren alarm which operates according to the state of the other three alarms Note if your process measurement is represented by a current or voltage signal you may be interested in the PMX420 Series displays General Technical Data Display Type Scaling Display range Status indicators Analogue output optional Type Scaling Range Current drive Voltage drive Output ripple Output action Input filtering Type Damping factor General Accuracy Linearity Repeatability Temperature drift Long term drift Frequency response Response time Insulation Co ordination Ports Rated Insulation Voltage Overvoltage Category Impulse Withstand Environmental Conditions Operating temperature Storage temperature Pollution Degree Relative humidity Housing Type Front bezel Approvals Mark DC Powered Units only con E205105 DC Powered Units only d LV Directive EMC Page 2 Weidm ller 2 p 137 00mm 143 5mm k sen gt 2 Z E E E 5 s 2 w GASKET _ 18 0mm PANEL THICKNESS Max 18 0mm E E id B e CUTOUT g E 5 5 g g E K E 8 2 a i 4 Full 4 digit red 14 2 mm LED To display in or engineering units 9999 to 9999 Alarm ch 1 4 and key status Analogue current voltage To represent any portion of the input range Any range inside the limit
6. m channels three and four fitted Custom input sensor supply voltage State voltage e g PMX400HZ FPS 24Vdc Type Cat No Model Supply Options PMX400HZX 24Vdc 7940015595 PMX400HZX 24Vdc RO AO 7940011979 For other ranges please specify PMX400HZX 1 2 where 1 Supply and 2 Options CE Os LISTED Connections Terminal Signal 1 Neutral Power supply 2 Live 3 Output Analogue output 4 Ouput AO option only 5 Common Alarm Channel One 6 Channel 1 and Alarm Channel Two 7 Channel 2 8 Security Link 9 Pull up down Inputs Security link 10 Signal OV Link 12 amp 8 for set up mode otherwise leave 11 Signal disconnected 12 12Vdc out See user manual for full explanation of input connections 13 Normally Closed 14 Common Alarm Channel Three RO option only 15 Normally Open 16 Normally Closed 17 Common Alarm Channel Four RO option only 18 Normally Open EET Subject to technical alterations without notice Printed in Australia e 7940015660 05 05 2009
7. ptions The basic software will control the optional analogue outputs and alarm channels without modification So to retrofit an option you can simply add a card calibrate and setup for your installation from the front panel To display in C F or mV Thermocouple PT100 RTD or mV Any range inside limits shown no recalibration required 50 C 58 F to 870 C 1598 F 50 C 58 F to 1372 C 2502 F 50 C 58 F to 1300 C 2372 F 50 C 58 F to 400 C 752 F P P P 50 C 58 F to 700 C 1292 F 0 C 32 F to 1820 C 3308 F 50 C 58 F to 1768 C 3214 F 50 C 58 F to 1768 C 3214 F 200 00mV to 200 00mV 220 0 C 364 0 F to 820 0 C 1508 0 F Automatic Automatic AC or DC powered 100 132 Vac 47 63Hz or 200 264 Vac 47 63Hz 20 28Vdc others on request AC 6VA or 6W at 24Vdc SPDT relay contacts 3A at 240Vac resistive 3A at 24Vdc resistive 1kV between channels 5 samples per second With analogue output fitted With all alarm channels fitted Type Cat No Model Supply Options PMX400TMP 24Vdc 7940017862 PMX400TMP 24Vdc 4RO AO 7940012968 For other ranges please specify PMX400TMP 1 2 where 1 Supply and 2 Options Mann Series PMX CE x LISTED Connections Terminal Signal 1 Neutral Power supply 2 Live 3
8. s 0 22 mA or 0 11 V Up to 850Q load at 20mA True voltage source up to 20mA Less than 20mV P P Direct reverse Digital filter programmable 1 to 99 default 2 Typically 0 1 of span Better than 0 05 0 02 of span Less than 0 02 span C 0 1 per 10 000 hours 3dB point 5Hz 300 mS for 10 90 output change digital filtering 1 Input Output Case 300Veff lll AKV 1 2 50 0 to 60 C 25 to 70 C 2 10 90 non condensing Panel mount 1 8 DIN format with IP65 rating Standard CAN CSA C22 2 No 142 M1987 1st Edition UL508 17th Edition EN50178 1998 BS EN 61326 1998 A2 5 0mm 0 6 0 0mm General set up menu options Display H ir Display brightness df Display Decimal Point Loz Display low dH lz Display high Inputs iP Input type iP Input range low IPH Input range high dF 2 Input filtering Analogue output AGPY Analogue Output OPL Output low GPH Output high GP d Output sense Alarms 1 4 general options Alley Alarms 1 amp 2 AJ4yY Alarms 3 amp 4 SETY Setpoint security n r Alarm reset mode Alarm options set for each channel A InE A IzH a ca wA mu Goo oo Ga an ca oO La E aag co Output Coil energisation Alarm Type Setpoint e g 50 00 units Introduces deadband e g 10 00 units Alarm Timer Delay e g 20 seconds High or Low 0 000 to 0000 alue alue