Home
SW6 VGA Audio
Contents
1. 1 2 Chapter Two Installation and Operation 2 1 Mounting the Unit sess 2 2 Tabletop placement 0 nnnnnn0annnnnonnnnnnnnnrnnnnnnrnnnnennennnrreennne 2 2 Rack moun AA EE 2 2 UL requirements nennen nnne 2 2 Mounting mstructons nnne 2 3 Under furniture mounting esssneneneneeneererrrrreerrreeeereeee 2 4 COnnectionS SNR RR 2 5 Audio connections sseeeeseenneeeeeeeerrrrt rtr rrrreereer rrr rnrrrnenene n 2 7 Oper d e EE 2 8 Controls and indicators A 2 8 Switch MOUEN NTC 2 10 Determining the switch mode 2 10 Selecting a switch mode sssseneeeeeeen nennen rn rrrreeennnnnenrn enn 2 10 Audio level control cccccecceeeeeeseeeeeeeeeaeeeeeeeesananeeeesens 2 11 Adjusting the audio level 2 11 Resetting all audio levels nnnnnsnonnnneeeeenen nnne nenen neereeeen 2 12 Chapter Three eRemote Control 3 1 Simple Instruction Set Control 3 2 Host to switcher communication 3 2 Switcher initiated unsolicited messages 3 3 Error Ce let EE 3 3 Ie de T azir ei ka ekta ja e kk ie kikit bin 3 3 Using the command response table 3 4 Symbol definitions 000aaeaeeaneaeneeeeneeeeeeeeenererrrrrrrrrrreee 3 4 Command response table for SIS commands 3 5 Windows Based
2. In 6 Input 6 oo Joo bk oh C 2 a Figure 2 5 Remote connector See chapter 3 Remote Control for definitions of the SIS commands serial commands to control the switcher via this connector and for details on how to install and use the control software To select an input using contact closure control momentarily tie an input s selection pin to ground Jeu Contact closure input selection cannot be performed when the auto switch mode is on SW6 VGA Audio Installation and Operation Audio connections See figure 2 6 to wire a connector for the appropriate input or output type and impedance level High impedance is generally over 800 ohms Tip eek O Ring CH O Sleeve s HQ Tip EH O Ring CN Q fe X Unbalanced Stereo Input Balanced Stereo Input 5 he high impedance high impedance Tip O g Ring CH Q St Sleeve s d Q Sa Tip QJ g D Ring aza Cl gi Unbalanced Stereo Output Balanced Stereo Output T m mwen li S D Do not tin the wires Figure 2 6 Captive screw connector wiring for audio The length of the exposed stripped portion of the copper wires is important The ideal length is 3 16 5 mm Longer bare wires can short together Shorter bare wires are not as secure in the captive screw connectors and could be pulled out CAUTION The input audio connectors can easily be inadvertently plugged partially into one receptacle and partially into
3. uondia sop jeuonippy osuodsay puewwo IDSV puewwuoj spueuuulo SIS 10 9 qe3 asuodsa ypuewuwoj S m oO om n S Sao 9G P zzo an 9 iv BYE 3 QATPT xaT V Q Q BL 89098 a2 48 8 3 e A og o D v lt a YO T coc LL LI 40 6 2K o E E A ees EE EE Q 2 SG Z a m x D Se AL c o gg S B8 N VE EE ao A x I os S 8e D ei d LSN o dz AS ED an i SZESEZO Se TE SS s eg e Deg gu Ge O an Ze E B5 Q O OA DOG MA ep o E B Bo Oo Saketead QD 2 568 Bs 5 Ki w E Hee sc E ein GS e o Soc 5 e S nu of uu sS GREEN o N OTS sa 2 TEREKE 5 E E E CECR a I 5 L gag tT Uugu CAE E EE Yo GR Gd B D o c ou 5 e o Q2 D o OU iS be Ou oo o E OG Q D TOU SE gt le O FY wee y 5 go c D Q o O E sa s a 3E af 10 G vsawase m Es oC 6S z X E Sp ELES Be she Se F EF FHo to ee EU S AO HK EIQ OoOzrzzyziuwg amp oo0m g22 Q i n mW I TNT l I J OosgESESS Z d c DA ou vo t YPESSESEs EL HH EE E E o E c OU un Vi 3 5 SW6 VGA Audio Remote Control SW6 VGA Audio e Remote Control 3 4 Remote Control cont d Windows Based Program Control The Windows based Extron Universal Switcher Control Program which communicates with the switcher via the Remote port provides an easy way to configure and operate the S W6 VGA Audio switcher The program is compatible with Windows 2000 and Windows XP or higher versions Installing the software The program
4. 100 VAC to 240 VAC 50 60 Hz 30 watts internal Temperature humidity Storage 40 to 158 F 40 to 70 C 10 to 90 noncondensing Operating 32 to 122 F 0 to 50 C 10 to 90 noncondensing EE eebe Convection unvented RACK TOUTAN esans ki ata asi a ina aaa Yes with optional 9 5 deep rack shelf part 60 190 01 RSU 129 or 60 604 01 RSB 129 Furniture mountable with optional under desk mounting kit part 70 219 01 MBU 129 Enclos re type gate seen Metal Enclosure dimensions 1 75 H x 17 1 W x 9 4 D IU high full rack wide 4 4 cm H x 43 4 cm W x 239 cm D Depth excludes connectors Product WON TI geed 4 5 Ibs 2 0 kg Shipping Wehi EE 7 lbs 4 kg VIDE UI ON EE ISTA 1A in carton International Safe Transit Association En ru T T sos tsat UL CUT CONTAC CS E CE FCC Class A RR kes 30 000 hours V T VAN Yo etale 3 years parts and labor NOTE All nominal levels are at 10 NOTE Specifications are subject to change without notice A 4 SW6 VGA Audio Reference Information Part Numbers Included parts These items are included in each order for an SW6 VGA Audio Included parts SW6 VGA Audio switcher 60 260 01 IEC power cord Tweeker small screwdriver SW6 VGA Audio User s Guide Captive screw 5 pole connectors 10 457 12 qty 7 Extron Software Products CD Universal Switcher Control Program Cables VGA M
5. IR 102 Kit Universal Remote Control OR to a remote contact closure device Remote coontrol of the switcher is via Extron s Simple Instruction Set SIS Extron s Windows based control rogram the IR 102 Kit or a contact closure device Contact PIN RS 232 Closure Function 1 In 1 Input 1 TX Transmit data REMOTE RX Receive data In 2 Input 2 Gnd Gnd Ground In 3 Input 3 In 4 Input 4 In 5 Input 5 In 6 Input 6 ED OMAN OA BW rn Figure 3 1 Remote connector pinout The RS 232 protocol of the rear panel Remote connector is 9600 baud 1 stop bit no parity and no flow control The connector has the pin assignments shown in figure 3 1 For RS 232 and IR control use a control cable with only pins 2 3 and 5 connected To accomplish this either cut the wires to the other pins in hard shelled connectors or remove the unneeded pins from molded plugs For contact closure use a control cable with pins 2 and 3 NOT connected To accomplish this either cut the wires to these pins in hard shelled connectors or remove these pins from molded plugs Switcher initiated unsolicited messages When a local event such as a front panel operation or error condition occurs the switcher responds by sending a message to the host The switcher initiated messages are listed below C COPYRIGHT 1998 EXTRON ELECTRONICS SW6VGA AUDIO Vx xx The switcher issues the copyright message
6. The command operation is aborted with no other indication 3 2 SW6 VGA Audio e Remote Control SW6 VGA Audio e Remote Control 3 3 Remote Control cont d TER UOISISA 91e Mull Aan r gt 107097 09N 1oquunu red 1sonbay 3onpoud sty 107 9 sAemye syndut jo requnu 101 au SI JA epou pue uonem3ruoo Wa sAs MOUS r 9IN e ox THAO e sxH el Oe e LXJA jsenba uoneurioju sjsonboJ uon euuojul Uorenusye 10 UES jo px s 2Ao orpne p andug r ex Pnv el lu Clan 2A9 orpne ndur moys uonenuoge JO gp px oi P491 orpne rx yndut jas gt PX Pnvy e rxur SEX Jo uonenuaye mdu yas ules JO qp 9 03 aA9 orpne q yndut jas p 9 pnveu Ge a duvxq ures jo gp px o1 2 9 orpne rx andui yas r X p nv e LX UI Cell ure3 jndur jas 201 18u25 ISVI FOU SI puvuinuoo BAS orpne MOUS IYJ 201j18u3s asuo adv spuvWWoOD 8 uorunuajjv Jas pwo 5 uws jas ayi EMN 9 9 Olpne 3nduJj uornoeres ndut 7 E7 Sy eued mot 0 spuodsaz 19q931Mg rcd TH opoui qojrAs penueu jag pex o q are uon2e es yndut ZEZ SY pue poued zuorg yuasaid euis e ur andui porequnu jsaysry ay sjoo es Afpeogyewojne 19q21T1Mg r id opou YD IMs ome Joe opoui u 3IMS Aemexes1q orpne mdyo se orpne rx andui p s r Xv jndur orpne 129 as Aemexes1q orpne mdyo se oopra rx andur p s XA jndur Oapta yeas 3nd3no se 9 3ndur p s ajduvxq yndut 3ndino se ry andur p s XID j orpne pue oaprA 129 2g spuewwo Buiy2 1M4S soy 03 yun zun 03 1sou
7. die nicht isoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen Bevor Sie das Ger t zum ersten Mal verwenden sollten Sie alle Sicherheits und Bedienungsanleitungen genau durchlesen und verstehen Aufbewahren der Anleitungen Die Hinweise zur elektrischen Sicherheit des Produktes sollten Sie aufbewahren damit Sie im Bedarfsfall darauf zur ckgreifen k nnen Befolgen der Warnhinweise Befolgen Sie alle Warnhinweise und Anleitungen auf dem Ger t oder in der Benutzerdokumentation Keine Zusatzgerate e Verwenden Sie keine Werkzeuge oder Zusatzgerate die nicht ausdr cklich vom Hersteller empfohlen wurden da diese eine Gefahrenquelle darstellen k nnen Instrucciones de seguridad Espanol Este s mbolo se utiliza para advertir al usuario sobre instrucciones importantes de operaci n y mantenimiento o cambio de partes que se desean destacar en el contenido de la documentaci n suministrada con los equipos Este s mbolo se utiliza para advertir al usuario sobre la presencia de elementos con voltaje peligroso sin protecci n aislante que puedan encontrarse dentro dela caja o alojamiento del producto y que puedan representar riesgo de electrocuci n Precaucion Leer las instrucciones Leer y analizar todas las instrucciones de operaci n y seguridad antes de usar el equipo Conservar las instrucciones Conservar las instrucciones de seguridad para futura con
8. FH BE AE 2 TABA A A an MAL e PEENE Log et CAK REHAR FLOREZ S BUT B DU REE MARRIR ARE AAS ML n eem e CN AA AAA LANS DFES eH PAN MA ONA SPEEA AA HG b BRA e mat AYEN SLEDS FE bl AJE ABELLA PATHE PLT Fo ps DURE AER FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation The Class A limits are designed to provide reasonable protection against harmful interference when the equipment is operated in acommercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense VIe This unit was tested with shielded cables on the peripheral devices Shielded cables must be used with the unit to ensure compliance with FCC emissions limits Chapter One IntroductiON 1 1 About the SW6 VGA Audio SWitchefr
9. about program features you can access the help program in any of the following ways e Click Start gt Programs gt Extron Electronics gt Universal Switcher Help e From within the switcher control program select Help gt Contents on the task bar e From within the switcher control program press the F1 key SW6 VGA Audio e Remote Control 3 7 Remote Control cont d Contact Closure Remote Control IR 102 Infrared Remote Control E S s 3 amp The Remote connector also provides a way to select an input euro to the switcher using a remote contact closure device Contact closure control uses pins on the Remote connector that are not used by the RS 232 interface Figure 3 5 shows the contact closure pin assignments Contact PIN RS 232 Closure Function 1 REMOTE OG Ze OO OO Jo Om BW rnm TX RX Gnd In 1 In 2 Gnd In 3 In 4 In 5 In 6 Input 1 Transmit data Receive data Input 2 Ground Input 3 Input 4 Input 5 Input 6 Figure 3 5 Remote connector pinout To select a different input number using a contact closure device momentarily short the pin for the desired input number to logic ground pin 5 To force one of the inputs to be always selected leave the short to logic ground in place The short overrides front panel input selections The optional Extron IR 102 kit consists of the following components e IR102 handheld remote control unit e VersaTools IR 102 rem
10. alimentaci n Los cables de alimentaci n el ctrica se deben instalar en lugares donde no sean pisados ni apretados por objetos que se puedan apoyar sobre ellos Reparaciones mantenimiento Solicitar siempre los servicios t cnicos de personal calificado En el interior no hay partes a las que el usuario deba acceder Para evitar riesgo de electrocuci n no intentar personalmente la reparaci n mantenimiento de este equipo ya que al abrir o extraer las tapas puede quedar expuesto a voltajes peligrosos u otros riesgos Ranuras y aberturas e Si el equipo posee ranuras o orificios en su caja alojamiento es para evitar el sobrecalientamiento de componentes internos sensibles Estas aberturas nunca se deben obstruir con otros objetos Bater a de litio Existe riesgo de explosi n si esta bater a se coloca en la posici n incorrecta Cambiar esta bater a nicamente con el mismo tipo o su equivalente recomendado por el fabricante Desachar las bater as usadas siguiendo las instrucciones del fabricante Extron s Warranty Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase In the event of malfunction during the warranty period attributable directly to faulty workmanship and or materials Extron Electronics will at its option repair or replace said products or components to whatever extent it shall deem necessary to restore said product to proper o
11. and no input is selected Meniz Front panel input selection cannot be performed when the auto switch mode is on G Mode button Use this button with either the Auto or the Normal button to manually turn auto switch mode on or off This button is a secondary function of the Input 1 button 4 Normal button Use this button with the Mode button to manually turn auto switch mode off This button is a secondary function of the Input 2 button 2 8 SW6 VGA Audio Installation and Operation SW6 VGA Audio Installation and Operation 2 9 Installation and Operartion cont d Switch modes The SW6 VGA Audio switcher operates in manual or auto switch mode e Manual switch mode Input selection is done using Input buttons 1 through 6 on the front panel or through the rear panel Remote connector contact closure or R5 232 e Auto switch mode The switcher automatically selects the highest number input that has sync pulses available Input selection by the front panel switches or through the Remote connector is blocked Determining the switch mode To determine which mode is active press and release an unselected input button Normal switch mode That input becomes the selected input Auto switch mode The switcher does not select the input associated with the button that you pushed Selecting a switch mode Switch between modes by pressing and holding the Mode Input 1 button and either the Normal Input 2 or
12. battery There is a danger of explosion if battery is incorrectly replaced Replace it only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Avertissement Alimentationse Ne faire fonctionner ce mat riel qu avec la source d alimentation indiqu e sur l appareil Ce mat riel doit tre utilis avec une alimentation principale comportant un fil de terre neutre Le troisi me contact de mise la terre constitue un dispositif de s curit n essayez pas de la contourner ni de la d sactiver D connexion de l alimentation Pour mettre le mat riel hors tension sans danger d connectez tous les cordons d alimentation de l arri re de l appareil ou du module d alimentation de bureau s il est amovible ou encore de la prise secteur Protection du cordon d alimentation Acheminer les cordons d alimentation de mani re ce que personne ne risque de marcher dessus et ce qu ils ne soient pas cras s ou pinc s par des objets R paration maintenance Faire ex cuter toutes les interventions de r paration maintenance par un technicien qualifi Aucun des l ments internes ne peut tre r par par l utilisateur Afin d viter tout danger d lectrocution l utilisateur ne doit pas essayer de proc der lui m me ces op rations car l ouverture ou le retrait des couvercles risquent de l exposer de hautes tensions et autres dangers Fe
13. female 15 pin HD 1 0 Vp p for Y of component video 0 7 Vp p for RGB and for R Y and B Y of component video Analog 0 3 V to 1 5 Vp p with no offset 75 ohms 15 kHz to 145 kHz 30 Hz to 170 Hz lt 42 dB 5 MHz 1 VGA OXGA RGBHV RGBS RGsB RsGsBs HDTV component video 1 female 15 pin HD 1 0 Vp p for Y of component video 0 7 Vp p for RGB and for R Y and B Y of component video Analog 0 3 V to 1 5 Vp p follows input 75 ohms lt 43 dB 5 MHz 5 mV maximum with input at 0 offset RGBHV RGBS RGsB RsGsBs bi level and tri level sync RGBHV RGBS RGsB RsGsBs bi level and tri level sync follows input 1V to 5 Vp p TTL 5 Vp p unterminated 510 ohms 75 ohms Positive or negative A 2 SW6 VGA Audio Reference Information Audio ei egi pens paka bon es T antan Unbalanced output 0 dB balanced output 6 dB Frequency response eessen 20 Hz to 20 kHz 0 05 dB THD EE 0 03 1 kHz 0 3 20 KHz at nominal level Bandwidth E 100 KHz at 3 dB DU IN in tk ep ki rek eet a ME D IL en gt 90 dB balanced at maximum output unweighted Crosstalk uertit oke sone ape ass knsessek lt 65 dB 20 kHz lt 80 dB 1 kHz and below 60 Hz fully loaded Stereo channel separation gt 80 dB 1 kHz gt 60 dB 20 kHz Gs E E gt 75 dB 20 Hz to 20 kHz Audio input Nu umber signal Ty PO sesura 6 stereo balanced unbalanced CCONDPGEIO TS eegene 6 3 5 mm captive screw connectors 5 pole
14. is contained on the Extron Software Products CD ROM disk B Install the software as follows 1 Insert the CD ROM into the drive The installation program should start automatically If it does not self start run Launch exe from the CD The Extron software CD window appears figure 3 2 Com UI SC CLCESELIFLISECIGLELECCR LTIISIH ZLOLITTILHTRC AILUUGLOLCLLCELEIULEILELE L LU amp Extron Software CD Microsoft Internet Explorer BAX File Edit view Favorites Tools Help w rad ix a Le Search S Favorites g gr 2 2 M Lj a ki Address EI D index html SC vl Be Links 7 Extron Software Products Extron Electronics e Disc B Issue 2007 1 800 633 9876 m DEA EN we L G q Home y extron com 4 Contact Us Extron Software Products Disc B Issue 2007 1 For more than 20 years Extron Electronics has manufactured professional A system products including computer video interfaces switchers matri switchers distribution amplifiers signal processing devices Ethernet control interfaces and high resolution cable Extron offers For vis ipio prague solutions for integration of video and audio into presentation systems for a variety of E environments such as boardrooms classrooms and training centers lecture halls command www extron com and control centers and more Products a Cl Software Find a product and view P ch Install control and ava
15. 1 12 13 eo0oooooosoeoosovesoegoddoooooooooooco O O Olo o olo o oloocoolooolole eoe ooo oo 0o l 106 o 0 0 O O O O O O O a e O O OJO dB dB 4 Press and hold the Audio Configuration Save button until the Audio Configuration Save LED goes out Release the button Nozi There is one audio gain or attenuation setting per input The setting is shared by the left and right audio inputs e The input audio gain or attenuation settings are stored in non volatile memory When power is removed and restored the audio level settings are retained SW6 VGA Audio Installation and Operation 2 11 Installation and Operartion cont d S s e Resetting all audio levels 5 Si To reset the audio level to 0 dB for all inputs press and hold the G f SW6 VGA Audic VGA Aud IO Switcher Audio Configuration Save button The Audio Configuration Save LED begins to blink after approximately 1 second Continue to hold the button for approximately 10 seconds until the LED turns off All input audio levels are reset to 0 dB Chapter Three Remote Control Simple Instruction Set Control Windows Based Program Control Contact Closure Control IR 102 Infrared Remote Control 2 12 SW6 VGA Audio Installation and Operation Remote Control The SW6 VGA Audio switcher s rear panel Remote connector figure 3 1 can be connected to the serial port output of a host device such as a computer or control system to an Extron
16. Auto Input 3 button until either the Normal or Auto LED blinks figure 2 10 Press and HOLD 1 2 3 e sec e MODE NORM AUTO A The blinking LED D indicates the mode Release the buttons Figure 2 10 Selecting a switch mode 2 10 SW6 VGA Audio Installation and Operation Audio level control AJ UP Loan The audio level setting for the 210 oo e ee selected input can be viewed soote ooo and changed within a range of 00 Pg 15 dB to 9 dB to ensure that oo we there is no noticeable volume wl SE co difference among sources 5 O E o Adjusting the audio level 4 Seen eRe View or change the audio input m 2 didis level as follows 2 eee 1 8 e o 1 Select an input 2 Press and hold the Audio Configuration Save button until the Audio Configuration Save LED blinks Release the button The Input LEDs indicate the audio level The dB and dB LEDs display the polarity gain or attenuation e Each Input LED shows a range of 3 dB Slow blink 1 dB Fastblink 2 dB Lit 3dB m e The dB LED lit A5 indicates a positive 1 2 gain level The off r blinking slowly dB LED lit XE blinking fast O on indicates a negative attenuation level Both LEDs lit indicate 0 dB 3 Press and release the A Input 5 or v Input 6 buttons to increase or decrease the audio level by 1 dB 1 1 1 1 1 1 1 1 oO CO N eo Wu Ja Co N 10 1
17. M MD 3 3 0 9 m 26 238 14 VGA M M MD 6 6 1 8m 26 238 01 VGA M M MD 10 10 3 0m 26 238 07 VGA M M MD 25 25 7 6 m 26 238 03 VGA M M MD 50 50 15 2m 26 238 18 Accessories RSU 129 1U Universal rack shelf 60 190 01 RSB 129 1U Basic rack shelf 60 604 01 MBU 129 Under desk mounting bracket 70 219 01 Mac HV VGA adapter 26 340 02 SY VGA XGA 26 173 01 KP 6 remote control keypad 60 111 20 IR 102 remote control kit 70 224 01 SW6 VGA Audio Reference Information A 5 Reference Information cont d A 6 SW6 VGA Audio Reference Information
18. Program Control 3 6 Installing the software nnnneennnnnnnnneeennernerrrereereeeeeseeeene 3 6 Using the software 3 7 Using the help system 3 7 Contact Closure Remote Control 3 8 IR 102 Infrared Remote Control 3 8 SW6 VGA Audio Table of Contents i Table of Contents cont d Appendix A e Reference InformatiON A 1 SCC ANIONS kot vii tis sayita e w ii A 2 Part Vtt A 5 included E EE A 5 i7 A 5 Accessories EE A 5 68 377 01 Rev E 03 08 AII trademarks mentioned in this manual are the properties of their respective owners SW6 VGA Audio Table of Contents na AN P amp HM af 7 SW6 VGA Audio Switcher turo Chapter One Introduction About the SW6 VGA Audio Switcher Introduction About the SW6 VGA Audio Switcher 3 The SW6 VGA Audio SW6 VGA A figure 1 is a 6 input une 1 output audio video switcher housed in a rack mountable 1U high full width metal enclosure with internal universal 100 240 VAC 50 60 Hz power supply Ze SW6 VGA Audio Switcher HM o2 A SE S PC wii Extron AUDIO SW6 VGA Audio INPUTS i Switcher Chapter Two oY 2 i Figure 1 Typical SW6 VGA Audio application Installation and Ope ration Mounting the Unit Connections Operation 1 2 SW6 VGA Audio Introduction Installation and Operartion Mounting the Uni
19. VUA Extron Electronics USA Extron Electronics Europe Extron Electronics Asia Extron Electronics Japan Pi S 1230 South Lewis Street Beeldschermweg 6C 135 Joo Seng Rd 404 01 Kyodo Building 16 Ichibancho D Anaheim CA 92805 3821 AH Amersfoort The Netherlands PM Industrial Bldg Singapore 368363 Chiyoda ku Tokyo 102 0082 ocu ot 800 633 9876 714 491 1500 800 3987 6673 31 33 453 4040 800 7339 8766 65 6383 4400 Japan www extron com FAX 714 491 1517 FAX 31 33 453 4050 FAX 65 6383 4664 81 3 3511 7655 FAX 81 3 3511 7656 2008 Extron Electronics All rights reserved o De Ee Ext Elect A Di WM XTTON EACCTTONICS oi INTERFACING SWITCHING AND DISTRIBUTION ocu o User s Manual Extron SW6 VGA Audio 6 input 1 output VGA QXGA and Stereo Audio Switcher 68 377 01 Rev E 03 08 Precautions Safety Instructions e English Thissymbolisintended to alertthe userof important operating and maintenance servicing instructions in the literature provided with the equipment This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product s enclosure that may present a risk of electric shock Caution Read Instructions Read and understand all safety and operating instructions before using the equipment Retain Instructions The safety instructions should be kept for future reference Follow Warnings Follow all warnings and instructions marked on the e
20. an adjacent receptacle Ensure that the connector is plugged fully and only into the desired input or output Tip Ring LI zm zg Sleeve RCA Connector 3 5 mm Stereo Plug Connector balanced Figure 2 7 Typical audio connectors SW6 VGA Audio Installation and Operation 2 7 Installation and Operartion cont d Operation 6 Auto button Use this button with the Mode button to manually turn auto switch mode on Controls and indicators y Auto is a secondary function of the Input 3 button 6 A and V buttons Use these buttons to increase or decrease the selected input s audio gain or attenuation These buttons are secondary functions of the Input 5 and Input 6 buttons a Audio Configuration Save button and LED Selects the audio mode in which you can set the input audio gain and attenuation level for each input Figure 2 8 SW6 VGA Audio front panel features dB and dB LEDs Indicate polarity gain or attenuation of input audio level setting Power LED Indicates that AC power is applied also on the rear panel figure 2 9 o3 Figure 2 9 Rear panel power connector 2 Input Buttons and LEDs When the auto switch mode is off these buttons select the input The LED for the selected input lights The LEDs continue to indicate the selected input when the auto switch mode is on If no input LED is lit no input has active sync pulses
21. ed when addressing this concern Reliable earthing grounding Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit such as the use of power strips 2 2 SW6 VGA Audio Installation and Operation Mounting instructions For optional rack mounting mount the 1U high full rack width switcher on either of the following rack shelves e RSU 129 9 IU universal rack shelf kit part 60 190 01 figure 2 1 e RSB129 9 IU basic rack shelf part 60 604 01 1U Universal Rack Shelf 2 4 40 x 3 Screws 6 Use 2 mounting holes on opposite corners Figure 2 1 Mounting the unit on a standard rack shelf If installed remove the feet from the bottom of the unit 2 Mount the unit on the shelf using two 4 40 x 3 16 screws in opposite diagonal corners to secure the unit to the shelf 3 Insert the shelf into the rack aligning the holes in the shelf with those of the rack 4 Secure the shelf to the rack using the supplied machine screws SW6 VGA Audio Installation and Operation 2 3 Installation and Operartion cont d Under furniture mounting If desired mount the S W6 VGA Audio under a desk or other furniture figure 2 2 with the optional MBU 129 under desk mounting bracket part 70 219 01 as follows 6 Insert 8 wood screws into the four pilot holes Tigh
22. ilable files a configuration software X My Computer Figure 3 2 Software CD window 2 Clickthe Software tab figure 3 2 3 Scroll to the desired program and click Install figure 3 3 Universal Switcher 29 031 02 3 7 Oct 6 2006 5 3 ME kinftall Control software for I the MAY 62 MME Switchers CS Swe Ma SW 4h6 Ma SW Component Model 8 10 Plus and AV Switchers Figure 3 3 Software installation 3 6 SW6 VGA Audio e Remote Control 4 Follow the on screen instructions By default the installation of the Universal Switchers Control Program creates a C Program FilesNExtronNUnivSW and it places four icons into a group folder named Extron Electronics Universal Switcher The four installed icons are e Check for Universal Switcher Updates e Uninstall Universal Switcher e Universal Switcher Control Program e Universal Switcher Help Using the software Run the program as follows 1 Click Start gt Programs gt Extron Electronics gt Universal Switcher Control Pgm 2 Click the comm port that is connected to the switcher s RS 232 port 3 The Extron Universal Switcher Control Program window figure 3 4 displays the selected video and audio input File Configure INPLITS e 6 o0 a amp 6 4 5 el gl o e o o 9 o M Video lw Audio MODE Ze Front Panel C Auto Switch Figure 3 4 Universal Switcher Control program window Using the help system For information
23. le or other furniture Mark the location of the brackets slotted screw holes on the mounting surface 5 Drill 3 32 2 mm diameter pilot holes 1 4 6 3 mm deep in the mounting surface at the marked screw locations 2 4 SW6 VGA Audio Installation and Operation SW6 VGA Audio Installation and Operation 2 5 Installation and Operartion cont d REMOTE OUTPUT Ee L 1 R HCH CEET TE Figure 2 4 SW6 VGA A rear panel right haif 4 Audio Input connectors Connect balanced or unbalanced stereo or mono audio inputs to HARE these 3 5 mm 5 pole captive screw connectors L t Connectors are included with each switcher but you must supply the audio cable See Audio connections on the next page to wire the connectors 6 Audio Output connector Connect a balanced or unbalanced stereo or mono audio device to JETT this 3 5 mm 5 pole captive screw connector EE Connectors are included with each switcher but you must supply the audio cable See Audio connections on the next page to wire the connectors 6 Remote connector Connect a host device such as a computer touch panel control or RS 232 capable PDA to the switcher via this 9 pin D connector for serial RS 232 control figure 2 5 Contact PIN RS 232 Closure Function 1 In 1 Input 1 TX Transmit data REMOTE RX Receive data In 2 Input 2 Gnd Ground In 3 Input 3 In 4 Input 4 In 5 Input 5
24. lied with respect to the product and its quality performance merchantability or fitness for any particular use In no event will Extron Electronics be liable for direct indirect or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage Please note that laws vary from state to state and country to country and that some provisions of this warranty may not apply to you EMA e AR a SI RR ik amp Rae A m KARA AY RA A EZAYI CHWA ea BI ARAB AS FH Ak BR neg e uae Ach Vcnus VER LIN SA SSH m an HA SURI ALA RETRETT HL ACA UAR Bie fest VURARUMP HMR RARA REVNE te HEP e AAAA A SET BAA ABBE VERA ANN NAN AAA BERGE PE IER B iEWLRH B e JH Ak FA 12 We AN 2 p 192
25. luni PEN AN GE kan atrap DEDERE 12k ohms unbalanced 25k ohms unbalanced DC coupled Nominal level sce p pise kanta a 10 dBV 316 mV Maximum level ess ecco cose toye de pass 18 dBu balanced or unbalanced at 1 THD N Input gain adjustment 15 0 dB to 9 0 dB adjustable per input NOTE 0 dBu 0 775 Vrms 0 dBV 1 Vrms 0 dBV 2 dBu Audio output Number signal type ea 1 stereo balanced unbalanced CCODTIGCEOTS esssecncecenzecieczastecanancentins 1 3 5 mm captive screw connector 5 pole TANDE AE s oce mediados 50 ohms unbalanced 100 ohms balanced Gali CITE asse sosisy do pise k k se sansa ase 0 1 dB channel to channel Nominal level esse rasis im aoi 4 dBV 63 1 mV Maximum level Hi Z 74 26 dBu balanced gt 21 dBu unbalanced at 1 THD N Maximum level 600 ohm gt 21 dBm balanced gt 15 dBm unbalanced at 1 THD N SW6 VGA Audio Reference Information A 3 Reference Information cont d Control remote switcher Serial control DOLE eser tis RS 232 9 pin female D connector Baud rate and protocol 9600 baud 8 data bits 1 stop bit no parity Serial control pin configurations 2 TX 3 RX 5 GND COTA CE CT OSUTE seggt egtegrteegeebg 9 pin female D connector Program controles ei son soi pasyan Extron s control configuration program for Windows Extron s Simple Instruction Set SIS General POWE zione t k eti sis kd veni cite dad
26. ntes et orifices Si le boitier de l appareil comporte des fentes ou des orifices ceux ci servent emp cher les composants internes sensibles de surchauffer Ces ouvertures ne doivent jamais tre bloqu es par des objets Lithium Batterie Il a danger d explosion s ll y a remplacment incorrect de la batterie Remplacer uniquement avec une batterie du meme type ou d un ype equivalent recommande par le constructeur Mettre au reut les batteries usagees conformement aux instructions du fabricant Vorsicht Stromquellen Dieses Gerat sollte nur ber die auf dem Produkt angegebene Stromquelle betrieben werden Dieses Ger t wurde f r eine Verwendung mit einer Hauptstromleitung mit einem geerdeten neutralen Leiter konzipiert Der dritte Kontakt ist f r einen Erdanschlu amp und stellt eine Sicherheitsfunktion dar Diese sollte nicht umgangen oder aufer Betrieb gesetzt werden Stromunterbrechung Um das Ger t auf sichere Weise vom Netz zu trennen sollten Sie alle Netzkabel aus der R ckseite des Ger tes aus der externen Stomversorgung falls dies m glich ist oder aus der Wandsteckdose ziehen Schutz des Netzkabels e Netzkabel sollten stets so verlegt werden dafs sie nicht im Weg liegen und niemand darauf treten kann oder Objekte darauf oder unmittelbar dagegengestellt werden k nnen Wartung e Alle Wartungsmafnahmen sollten nur von qualifiziertem Servicepersonal durchgef hrt werden Die internen Komponenten des Ger tes sind war
27. ote receiver with 3 cable and RS 232 connector e IR detector with 6 cable and captive screw connector e External 12 VDC power supply Install and operate the remote control in accordance with the IR 102 User s Guide included with the remote REMOTE Tromm IR 102 Remote Control IR Detector Supply D 3 Cable RS 232 Control Extron IR 102 Remote Control Receiver Figure 3 6 IR 102 Remote application SW6 VGA Audio e Remote Control Appendix A Reference Information Specifications Part Numbers Reference Information Specifications Video Bandwidth E ke FOSE LA cst pon piston dent bat esse a ae Video input Number signal type Connectors eegenarteg deeg Nominal level Minimum maximum levels EE ecciesia emen Horizontal frequency E UE taps IER Video output Number signal type esce Connectors s sross ason sa stnedesosense seate Nominal level seen teme Minimum maximum levels Ila t PEUT akote kaw ekta NUN UNDE Return 1088 cotra no isat netos X OBS eee ane an ata apik sito daki Sync Input DY DO sensisse todas KEE Input I vel E utpat evel ioci etit pieds Input AAA osc Eege Output impedance suce ierra leegen Unity 350 MHz 3 dB lt 68 dB 10 MHz 39 dB 100 MHz 6 VGA OXGA RGBHV RGBS RGsB RsGsBs HDTV component video 6
28. perating condition provided that it is returned within the warranty period with proof of purchase and description of malfunction to USA Canada South America and Central America Europe Africa and the Middle East Extron Electronics Europe Extron Electronics Beeldschermweg 6C 1001 East Ball Road 3821 AH Amersfoort Anaheim CA 92805 USA The Netherlands Asia Japan Extron Electronics Asia Extron Electronics Japan 135 Joo Seng Road 04 01 Kyodo Building PM Industrial Bldg 16 Ichibancho Singapore 368363 Chiyoda ku Tokyo 102 0082 Japan This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or non Extron authorized modification to the product If it has been determined that the product is defective please call Extron and ask for an Applications Engineer at 714 491 1500 USA 31 33 453 4040 Europe 65 6383 4400 Asia or 81 3 3511 7655 Japan to receive an RA Return Authorization number This will begin the repair process as quickly as possible Units must be returned insured with shipping charges prepaid If not insured you assume the risk of loss or damage during shipment Returned units must include the serial number and a description of the problem as well as the name of the person to contact in case there are any questions Extron Electronics makes no further warranties either expressed or imp
29. quipment or in the user information Avoid Attachments Do not use tools or attachments that are not recommended by the equipment manufacturer because they may be hazardous Consignes de S curit Francais Ce symbole sert avertir l utilisateur que la documentation fournie avecle mat riel contient des instructions importantes concernantl exploitation et la maintenance r paration Ce symbole sert avertir l utilisateur de la pr sence dansle boitier del appareil de tensions dangereuses non isol es posant des risques d lectrocution Attention Lire les instructions Prendre connaissance de toutes les consignes de s curit et d exploitation avant d utiliser le mat riel Conserver les instructionse Ranger les consignes de s curit afin de pouvoir les consulter l avenir Respecter les avertissements e Observer tous les avertissements et consignes marqu s sur le mat riel ou pr sent s dans la documentation utilisateur Eviter les pi ces de fixation Ne pas utiliser de pi ces de fixation ni d outils non recommand s par le fabricant du mat riel car cela risquerait de poser certains dangers Sicherheitsanleitungen Deutsch Dieses Symbol soll dem Benutzer in der im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung Instandhaltung geben DiesesSymbolsollden Benutzer darauf aufmerksam machen da im Inneren des Geh uses dieses Produktes gef hrliche Spannungen
30. sulta Obedecer las advertencias Todas las advertencias e instrucciones marcadas en el equipo o en la documentaci n del usuario deben ser obedecidas Evitar el uso de accesorios No usar herramientas o accesorios que no sean especificamente recomendados por el fabricante ya que podrian implicar riesgos Warning Power sources This equipment should be operated only from the power source indicated on the product This equipment is intended to be used with a main power system with a grounded neutral conductor The third grounding pin is a safety feature do not attempt to bypass or disable it Power disconnection To remove power from the equipment safely remove all power cords from the rear of the equipment or the desktop power module if detachable or from the power source receptacle wall plug Power cord protection e Power cords should be routed so that they are not likely to be stepped on or pinched by items placed upon or against them Servicing Refer all servicing to qualified service personnel There are no user serviceable parts inside To prevent the risk of shock do not attempt to service this equipment yourself because opening or removing covers may expose you to dangerous voltage or other hazards Slots and openings If the equipment has slots or holes in the enclosure these are provided to prevent overheating of sensitive components inside These openings must never be blocked by other objects Lithium
31. t CAUTION Installation and service must be performed by authorized personnel only The 1U high full rack width unit can be placed on a tabletop mounted on a rack shelf or mounted under a desk or other furniture Tabletop placement Affix the four included rubber feet to the bottom of the unit and place it in any convenient location Rack mounting UL guidelines The following Underwriters Laboratories UL guidelines pertain to the installation of as SW6 VGA Audio into a rack figure 2 1 1 Elevated operating ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consider installing the equipment in an environment compatible with the maximum ambient temperature Tma of 122 F 50 C specified by Extron Reduced air flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised Mechanical loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading Circuit overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Appropriate consideration of equipment nameplate ratings should be us
32. ten each screw into the mounting surface until just less than 1 4 of the screw protrudes 7 Align the mounting screws with the slots in the brackets and place the switcher against the surface with the screws through the bracket slots 8 Slide the switcher slightly forward or back then tighten all four screws to secure the switcher in place Connections OUTPUT vss ojo SE SEN m Remove and discard 4 screws from top Figure 2 3 SW6 VGA A rear panel left half Replace with supplied SE AC power connector Plug a standard IEC power cord into this connector to connect the switcher to a 100 VAC to Under Desk 240 VAC 50 or 60 Hz power source Mounting Bracket Video Input connectors Connect up to six RGBHV computer video VGA QXGA to these 15 pin HD connectors Nolia The switcher can also accept RGBS RGsB RsGsBs and HDTV component video B 4 Screws Gi Video Output connector Connect an RGBHV VGA QXGA video display to this female 15 pin HD connector Figure 2 2 Mounting the unit under a desk 1 If installed remove the feet from the bottom of the unit 2 Remove and discard the four screws in the top of the switcher 3 Using the screws supplied in the mounting bracket kit secure the mounting brackets to the top of the switcher with the slotted holes on the outside 4 Hold the switcher with the attached brackets against the underside of the tab
33. tungsfrei Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall dieses Ger t selbst ffnen da beim Entfernen der Abdeckungen die Gefahr eines elektrischen Schlags und oder andere Gefahren bestehen Schlitze und ffnungen e Wenn das Ger t Schlitze oder L cher im Geh use aufweist dienen diese zur Vermeidung einer Uberhitzung der empfindlichen Teile im Inneren Diese Offnungen d rfen niemals von anderen Objekten blockiert werden Litium Batterie e Explosionsgefahr falls die Batterie nicht richtig ersetzt wird Ersetzen Sie verbrauchte Batterien nur durch den gleichen oder einen vergleichbaren Batterietyp der auch vom Hersteller empfohlen wird Entsorgen Sie verbrauchte Batterien bitte gem t den Herstelleranweisungen Advertencia Alimentaci n el ctrica e Este equipo debe conectarse nicamente a la fuente tipo de alimentaci n el ctrica indicada en el mismo La alimentaci n el ctrica de este equipo debe provenir de un sistema de distribuci n general con conductor neutro a tierra La tercera pata puesta a tierra es una medida de seguridad no puentearia ni eliminaria Desconexi n de alimentaci n el ctrica e Para desconectar con seguridad la acometida de alimentaci n el ctrica al equipo desenchufar todos los cables de alimentaci n en el panel trasero del equipo o desenchufar el m dulo de alimentaci n si fuera independiente o desenchufar el cable del recept culo de la pared Protecci n del cables de
34. when it first powers on Vx xx is the firmware version number Cnet The switcher issues the Cn message when a front panel input selection operation occurs and immediately following the copyright message n is the input number Reconfig lt 4 The switcher initiates this message when there is a change in an audio gain setting Error responses When the switcher receives a valid SIS command it executes the command and sends a response to the host device If the switcher is unable to execute the command because the command is invalid or it contains invalid parameters the switcher returns an error response to the host The error response codes are E01 Invalid input channel number out of range E06 Invalid input channel change auto switch mode active E09 Invalid function mode parameter E10 Invalid command Simple Instruction Set Control E13 Invalid value out of range Host to switcher communications SIS commands consist of one or more characters per field No special characters are required to begin or end a command character sequence When a command is valid the switcher executes the command and sends a response to the host device All responses from the switcher to the host end with a carriage return and a line feed CR LF lt 4 which signals the end of the response character string A string is one or more characters Timeout Pauses of 10 seconds or longer between command ASCII characters result in a timeout