Home

Asema S3 User Manual

image

Contents

1. the mode is off by default and may cause delays in response time in installations where the input power to the Asema S is cut regularly Settings for Asema S series con trollers ASTMA 9 11 4 Troubleshooting This section lists a few common problems you may encounter into while using your controller and common remedies to them For a more complete list of howto s and up to date answers to problems visit the FAQ section on our support website at support asema com Cannot detect a controller If a controller cannot be found when detecting a controller the problem can be the cause of four basic reasons 1 the controller is not connected to mains power 2 the radio reception is poor 3 the controller is already paired or 4 the device is broken First make sure the controller is properly connected On Asema S1 the LED light will blink to indicate a proper mains connection On Asema S3 when power on pressing the foot switch will cause a tick sound when the relay switches on After making sure you have power make sure there are no interfering obstacles between the con troller and an Asema E and the distance between the two does not exceed 30 meters Make sure that the controller is not already paired A paired controller no longer sends a beacon and cannot therefore be detected To have the controller send beacon again reset it either from the Asema E in case of a controller paired to that Asema E or from the reset button
2. Cannot pair a controller Pairing a controller requires a good radio connection between the controller and Asema E Make sure you have no interfering elements between the devices and the distance is short enough For troubleshooting purposes you may want to move your Asema E closer to the controller to see how distance affects the radio connection Use the bar indicators to check the field strength if necessary Slow response to commands If your controller works but the operation seems sluggish this is most likely due to poor radio cover age The commands are slow because they need to be resent many times before a valid command can be pushed through To improve the response you may want to place the devices differently to avoid radio disturbance Placing another controller in between the devices may also help as a repeater Note also that radio antennas are always directional to some directions and reflections from walls and other structures will affect the way radios work Try to move or rotate your Asema E a bit this may help the radio connection considerably Troubleshooting ASEMA 10 11 Recycling At the end of its serviceable life this product should not be treated as household or general waste It should be handed over to the applicable collection point for recycling of electrical and electronic equipment or returned to the supplier for disposal You are liable to dispose of all your electronic or electrical waste equipment by
3. Unwrap the Scuko cables if wrapped and detach the wall mount Attach the Asema S3 wall mount to the desired location with screws Make sure that the cable can reach the distance to the socket 2 Snap the controller onto its lock on the mounting rail Installation ASEMA 2 11 Installation 3 Connect the power cable of the appliance to the Asema 53 4 Connect the Asema S3 to the wall socket The unit also functions as a power switch Push on the unit to switch the power on or off 1 3 Socket installation 1 Attach the Asema S3 mounting rail to the controller see 1 1 Wrapping and unwrapping the cable 2 Wrap the power cord around the mounting rail and slide the cablehead to its slot see see 1 1 Wrapping and unwrapping the cable 3 Connect the power cable of the appliance to the Asema S3 and connect the Asema S3 to a power socket The unit also functions as a power switch Push on the unit to switch the power on or off 1 4 Floor installation 1 Unwrap the cables of the Asema 53 and remove the wall mount see 1 1 Wrapping and unwrapping the cable 2 Connect the appliance power cable to the Asema S3 socket 3 Connect the Asema S3 cable to the power socket and place the Asema S3 on the floor 4 The unit also functions as a floor switch Push the top cover of Asema S3 to switch the appliance on or off Installation ASEMA 3 11 Installation 1 5 Connecting an a
4. To perform the manual reset you must have the controller connected to mains power Then simply press the reset button The controller will beep as an indication of reset You can find the reset button as follows On an Asema S1 the reset button is the transparent button with blinking red LED light On an Asema 52 the reset button is the gray button in front marked with RESET On an Asema S3 the reset button is the transparent button with blinking red LED light found under the top cover of the device Mesh networking and repeaters Mesh networking means that controllers with a radio can relay messages automatically between them and this way extend the range of communication or go around obstacles Thus they work automatically as repeaters of messages for each other Asema S series controllers and Asema M series meters can automatically form a mesh network You do not have to do anything to enable mesh networking the devices will do this automatically However you may benefit from knowing the topology of the mesh network as placing a controller between two controllers that have trouble communicating with each other may improve the situation To get most out of mesh networking take a look at the radio quality signals of the controllers Read 2 3 Radio quality measurement to see how this is done The Hop count measure tells you how many repeaters are between the Asema E and the controller you are analyzing If you see a low hop count
5. is closer The message then hops from one controller to another and the same way back In this way the distance a radio message is increased significantly The maximum number of hops is four You should try to get reading under three for optimal performance See also Section 3 6 Mesh Networking 2 4 Removing the controller To remove or unpair a controller follow the following steps 2 4 1 Removing the controller on the device 1 Go to Main Setup gt Appliances gt Appliances This will list all the connected appliances and their controllers Click on the gear icon of the appliance you want to remove This will open up a form with all the settings for this controller Click on Delete It will give you a pop up asking if you are sure that you want to remove this appli ance Click on OK You will then get a second pop up asking if you would also like to remove the controller Click OK You will then see the device processing the data You will be notified when the appliance has been removed and when the controller has been reset The controller is now removed from the system reset and can be paired again with any Asema E system When you click on Detect it will immediately detect the unpaired controller 2 4 2 Removing the controller in WebView 1 Go to WebView and click on Appliances This will list all the connected appliances 2 Click on the gear icon of the appliance you want to remove This
6. relocating over to the specified collection point for recycling of such hazardous waste Isolated collection and proper recovery of your electronic and electrical waste equipment at the time of disposal will allow us to help conserving natural resources Moreover proper recycling of the electronic and electrical waste equipment will ensure safety of human health and environment RoHS compliance This product is in compliance with Directive 2002 95 EC of the European Parliament and of the Council of 27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment ROHS and its amendments For full compliance statements please visit www asema com Recycling ASEMA 11711
7. you will be returned to the list of controllers including the unpaired ones Repeat step 4 5 for all unpaired controllers until all controllers are paired You re done The controllers will now also automatically be added to the ON OFF Power Consump tion History and Power Meter screenlets of an Asema E and appear there when you run these Radio quality measurement The Asema controller communicates with the Asema E device through radio signals on 434 MHz fre quency If your system is having problems such as the buttons not switching ON or OFF appliances when you click on them it might be that there are some problems with the radio signal In certain in stallations or buildings the radio signal gets interference either from other signals or due to the nature of the building such as for example thick steel walls The Asema E can diagnose the radio quality 2 3 1 Radio quality measurement on the device 1 Go to Main Setup gt Appliances gt Controllers This will list all the controllers you have paired with the device At the end of each Asema controller listed you will see the test icon below ed Tap on it 1 This will send a test message to all controllers which will test the radio quality It will return 4 values Device identifier This is simply the ID of the controller in your system Signal quality This shows a value between 1 and 100 On average a good working connection should show between 50 and 70 Pa
8. English Asema S3 User Manual Asema Electronics Ltd Copyright 2011 2013 No part of this publication may be reproduced published stored in an electronic database or transmitted in any form or by any means electronic mechanical recording or otherwise for any purpose without the prior written permission from Asema Electronics Ltd Asema E is a registered trademark of Asema Electronics Ltd ASEMA Table of Contents Safety alle 1 T Instaliationi srl 2 1 1 Wrapping and unwrapping the cable nen 2 1 2 Wall Installationi 2 en 2 1 3 Socket installation en ea ei a 3 VA FIGOP installation ass eh chen a 3 1 5 Connecting an appliance nennen 4 2 Pairing and communicating with Asema E _ nennen rn nnrnen re 5 2 1 Detecting pairing and naming controllers on the device en 5 2 2 Detecting pairing and naming controllers using the WebView 5 2 3 Radio quality Measurement ul i aa 6 2 3 1 Radio quality measurement on the device i 6 2 3 2 Radio quality measurement in the WebView nenn 7 24 Removingrthe Controller aan 7 2 4 1 Removing the controller on the device i 7 2 4 2 Removing the controller in WebView ii 7 2 5 Resetting the controller cece eeeeceeeeeceeecceaeeceeeeeeeeeseaeeeceeseeegeeseeeeceeeesseseeeeeees 8 2 6 Mesh networking and repeate
9. but a bad radio quality this means that the radio is suffering from disturbance due to distance or obstacles Placing another controller in a location that is between the two devices possibly so that it allows to bypass an obstacle will improve your installation Pairing and communicating with Asema E ASEMA 8 11 3 Settings for Asema S series controllers 3 1 3 2 3 3 In addition to automation features that work when connected to the Asema E Asema S series con trollers support a set of independent safety and control settings that can be modifies with the Asema E but work after that independent of the radio connection to the Asema E Default relay mode When an Asema S series is in factory settings after the controller gets power it will be in OFF mode Consequently it will not feed power to the appliance it controls unless the controller is switched on by using the controls of Asema E The reason for having power switched OFF by default is fire safety and electrical safety If for some reason during a blackout easily flammable material is placed on top of an appliance turning power back on will not cause a fire hazard In some cases it is however desirable to have the power switched ON by default This is especially true if the Asema S series controller controls a refrigerator or digital recorder If the default mode has not been changed from its factory setting the appliance will not receive power even after a very shor
10. cket loss the percentage of data packages that is lost in transmission This value should not be more than 10 Pairing and communicating with AsemaE ASCMA 6 11 Pairing and communi cating with Asema E Hop count the Asema E system can send messages to one controller that is far away using another controller that is closer The message then hops from one controller to another and the same way back In this way the distance a radio message is increased significantly The maximum number of hops is four For optimal performance you should try to get a hop count below three See also Section 3 6 Mesh Networking 2 3 2 Radio quality measurement in the WebView 1 Go to WebView gt Appliances gt Controllers This will list all the controllers you have paired with the device Atthe end of each Asema controller listed you will see an icon labeled QA Tap on it 2 This will send a test message to all controllers which will test the radio quality It will return 4 values which you will see in the pop up Device identifier This is simply the ID of the controller in your system Signal quality This shows a value between 1 and 100 On average a good working connection should show between 50 and 70 Packet loss the percentage of data packages that it lost during transmission This should not be more than 10 Hop count the Asema E system can send messages to one controller that is far away using another controller that
11. his lt Controls Appliances 0000 0000 0000 1003 m 1002 wm 1001 The controllers don t have a name yet just acode on the top which corresponds with the sticker that you received with your controller To distinguish which controller is which you can either compare the displayed code to the sticker or click on the sound icon top button The controller will beep which will help you in recognizing which controller you are currently adding Click on the gear icon middle button to edit the controller Fill in a name for the controller that will help you distinguish it We recommend naming it after the appliance you will connect to it From the drop down menu choose an appliance type 5 Click OK The controller will now be saved and you will be returned to the list of controllers including the unpaired ones Repeat step 4 5 for all unpaired controllers until all controllers are paired 6 You re done The controller will now also automatically be added to the ON OFF Power Consumption History and Power Meter screenlets of an Asema E and appear there when you run these 2 2 Detecting pairing and naming controllers using the WebView 1 Go the the WebView You do this by typing in the IP address of your device into a browser on your computer You can find the IP address either in Main Setup or by clicking on the black status bar at the top in the E view Once the application is loaded in your browser click on Appliances This
12. ppliance Connecting an appliance to the Asema S3 is very easy Just connect the Schuko power cable of the appliance to the female Schuko cable of Asema S3 Asema S3 supports appliances with a total power consumption up to 3680 Watts This is the largest amount of power that can be extracted from a single phase in a household so connecting a standard appliance or even many of them to an Asema S3 is safe Note however the maximum limit when connecting non standard or industrial equipment Do not exceed the 230V 1 6A limit Failing to do so will cause overheating which will eventually break the device Asema S3 has a safety fuse which will cut of power in case of overloading An overloaded Asema S3 can only be repaired by an authorized repair shop Installation ASEMA 4 11 2 Pairing and communicating with Asema E In order for the Asema E to communicate with the Asema controllers they need to be paired first After pairing the Asema E can send ON OFF messages to the controllers and read real time information on the electricity use Pairing can be done either using the device or in the WebView 2 1 Detecting pairing and naming controllers on the device 1 On the Asema E go to Main Setup gt Appliances gt Appliances 2 Click Detect The Asema E will now scan all Asema controllers which are not yet paired and list them on the screen This can take a few seconds 3 The result will be list of controllers looking like t
13. qualified electrician immediately Slots and openings in the product are provided for ventilation These openings must not be blocked or covered Loss of ventilation may cause the product to overheat If you notice anything unusual about the product such as loose wires exposed cabling burn marks holes in the insulating materials or damage to the product stop immediately When a power supply unit is included with the product only use the designated power supply unit Other usage may be dangerous and will invalidate any approval given to this product Unless specifically indicated otherwise the product is designed to operate in room temperature under dry conditions Keep the device dry and away from excessive moisture water or any liquid as it may cause a short circuit Keep the device away from extreme temperatures If this product is equipped with a USB port for connecting to a power or a computer note that connecting to improperly grounded equipment can result in an electric shock to your device Be sure your computer is properly grounded earthed before connecting this product to a computer Do not use this product in gas stations fuel depots chemical plants or where blasting operations are in progress or in potentially explosive atmospheres such as fueling areas fuel storehouses below deck on boats chemical plants fuel or chemical transfer or storage facilities and areas where the air contains chemi cals or particles such as g
14. rain dust or metal powders Please be aware that sparks in such areas could cause an explosion or fire resulting in bodily injury or even death This product may cause medical equipment to malfunction The use of this device is forbidden in most hos pitals and medical clinics There is no need to open the product YOUR WARRANTY IS INVALIDATED IF YOU DISASSEMBLE OR AT TEMPT TO DISASSEMBLE THE DEVICE ASEMA 1 Installation 1 1 Wrapping and unwrapping the cable The Asema S3 is designed so that the cables can be both wrapped around the switch and form a very compact unit to be inserted into a wall socket or the cables can be unwrapped to release the structure and make the device a floor switch See the image below To wrap the cable first attach the wall mount into the base of the Asema S3 Then bend the male mains cable slightly down and wrap it along the long edge of the wall mount Push the cable to the curved shape at the narrow edge and again back along the other long edge Finally push the male Schuko head into the slot in the middle of the wall mount Important If the Asema S3 is used to measure or control an appliance that needs electrical supply after a purposeful or accidental blackout such as a refrigerator or freezer the default power supply mode should be switched from its factory setting OFF to ON For more information please see chapter 3 1 Default relay mode 1 2 Wall installation 1
15. rs i 8 3 Settings for Asema S series controllers eee ce eeeeceeeeeeeeecaeeeeaeeeeseeeeaaeeeeeeeseeeeaees 9 3 1 Default relay Mode iis Aerei 9 3 2 Safety LIMON son LO a 9 3 3 5Added radio Security clara nia ona 9 4 TFOUDIESMOQUMG una nee en i a 10 Asema 53 ASCMA ii 11 Safety Please read this before proceeding and follow the safety precautions below when installing and operating the system Retain and follow all product safety and operating instructions Observe all warnings in the operating instructions on the product Operate your appliances responsibly especially when controlling them with remote controls or over the Inter net Remote control of appliances in an Asema system is disabled by default to prevent accidental damage Enable remote control only on devices where you can be certain damage cannot occur due to for instance heat fire smoke or water you do not notice while not present Always use an authorized and qualified electrician when installing products that involve rewiring electrical connections changes to the distribution box or opening wall sockets or other components embedded into walls floors or ceilings Live cables can only be accessed by a qualified electrician Do not force or bend the cables at any point during installation Do not drop throw or try to bend the product If you are worried or have any concerns about the installation please contact a
16. t blackout When the default mode is ON the power will be automatically switched on when power returns to the controller To change the default mode enter the settings of the appliance in case and tick the box marking that the default mode is ON Safety timer The safety timer switches the relay OFF automatically after the configured number of seconds has passed since the last ON switch Every time the controller is put to ON state the timer starts counting again Once the counter reaches zero the relay switches OFF The safety timer is a convenient and secure method to implement for instance automatic switch off of such home appliances as an electric stove If you are worried that the stove if easily left accidentally on the Asema S will turn it off e g after one hour of use In case the appliance uses three phase power connect the Asema S series controller to a contactor and let the contactor cut the actual power Added radio security In added security mode the Asema S series controller will add and require a specific random security token in each radio message With the added token it is virtually impossible for a malicious person to try to interfere with the network by recording and replaying radio traffic Using the security token is recommended if you operate in an environment where extra protection is needed Because setting up this security while establishing a communication link takes slightly longer than in standard radio traffic
17. will open up the Appliances page If this is the first time you add a controller the page will be almost empty If you have added controllers before they will be listed here 2 Click Detect The Asema E will now scan all Asema controllers which are not yet paired and list them on the screen This can take a few seconds 3 The result will be list of controllers looking like this Pairing and communicating with Asema E ASEMA 5 11 Pairing and communi cating with Asema E 2 3 Il Asema E Mozilla Firefox we w Eile Edit View History Bookmarks Tools Help E lAsemaE Appliances To control lances with Asema E add them to the list of inces Click tap Detect to find them automatically RAR enter tar norman merce biro Di The controllers don t have a name yet just a code on the top which corresponds with the sticker that you received with your controller To distinguish which controller is which you can either compare the displayed code to the sticker on the controller or click on the sound icon top button The controller will beep which will help you in recognizing which controller you are currently adding Click on the gear icon middle button of the controller you want to pair This will open up a form Fillin a name for the controller that will help you distinguish it We recommend naming it after the appliance you will connect to it Click OK The controllers will now be saved and
18. will open up a form with all the settings for this controller Pairing and communicating with AsemaE ASCMA 7 11 Pairing and communi cating with Asema E 2 5 2 6 3 Click on Delete It will give you a pop up asking if you are sure that you want to remove this appli ance Click on OK You will then get a second pop up asking if you would also like to remove the controller Click OK 4 You will then see the browser processing the data You will be notified when the appliance has been removed and when the controller has been reset 5 The controller is now removed from the system reset and can be paired again with any Asema E system When you click on Detect it will immediately detect the unpaired controller Resetting the controller Each Asema S series device has a dedicated reset button for removing pairing data from the controller itself manually You should always try to reset a control from the Asema E first before doing a manual reset A manual reset will simply remove the pairing from the controller without telling about this to an Asema E It will therefore result in a ghost controller on the Asema E that can no longer be reached You can however remove the ghost controller with a forced delete on the Asema E Please refer to Asema E manual for more information The manual reset is needed if you have lost pairing data on your Asema E due to replaced equipment accidental deletion or other similar reason

Download Pdf Manuals

image

Related Search

Related Contents

Progettare ed installare un impianto fotovoltaico  PowrTwin 3500™  Guia del usuario Bona Create color parquet  Clarion Report 2011  Istruzioni per l'uso Operating Instructions Mode d'emploi  RNAscope® Fluorescent Multiplex Kit Guide luorescent Multiplex Kit    Liebherr IC 2966 Premium  LAN ボード    

Copyright © All rights reserved.
Failed to retrieve file