CE EMC TEST REPORT
Contents
1. CP0630 6V 3A CP0620 6V 2A CP0610 6V 1A CP0540 5V 4A CP0530 5V 3A CP0520 5V 2A CP0510 5V 1A CP050085 5V 0 85A Brand Coming Data Coming Data Co Ltd 5F 1 No13 WU CHUNG 1 RD HSIN CHUNG CITY TAIPEI HSIEN TAIWAN R O C Coming Data Co Ltd 5F 1 No13 WU CHUNG 1 RD HSIN CHUNG CITY TAIPEI HSIEN TAIWAN R O C Tested August 21 22 2009 Test Voltage 230VAC 50Hz Model Applicant Manufacturer EN 55024 1998 A1 2001 A2 2003 IEC 61000 4 2 1995 A1 1998 A2 2000 IEC 61000 4 3 2006 IEC 61000 4 4 2004 IEC 61000 4 5 2005 IEC 61000 4 6 2003 A1 2004 A2 2006 IEC 61000 4 8 1993 A1 2000 IEC 61000 4 11 2004 Deviation from Applicable Standard The radiated emissions test items was tested at Compliance Certification Services Inc Linkou Lab EN 55022 2006 A1 2007 Class B EN 61000 3 2 2006 Class A EN 61000 3 3 2008 Applicable Standards The test equipments were listed in page 20 and the test data please refer page 23 24 The above equipment has been tested by Compliance Certification Services Inc and found compliance with the requirements set forth in the technical standards mentioned above The results of testing in this report apply only to the product system which was tested Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties Approved by Rev
2. 230 230 1000 Note 1 The lower limit shall apply at the transition frequencies 2 Emission level dBuV m 20 log Emission level uV m 7 3 2 TEST INSTRUMENTS Name of Equipment Manufacturer Model Serial Number Calibration Due EMI Test Receiver 03 03 2010 Pre Amplifier 04 02 2010 Bilog Antenna 06 20 2010 Turn Table 2081 1 21 N A Note 1 The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML ROC and NIST USA 2 N C R No Calibration Request Page 21 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 7 3 3 TEST PROCEDURE please refer to measurement standard or CCS SOP PA 031 Procedure of Preliminary Test The equipment was set up as per the test configuration to simulate typical usage per the user s manual When the EUT is a tabletop system a wooden turntable with a height of 0 8 meters is used which is placed on the ground plane When the EUT is a floor standing equipment it is placed on the ground plane which has a 3 12 mm non conductive covering to insulate the EUT from the ground plane Support equipment if needed was placed as per EN 55022 All I O cables were positioned to simulate typical usage as per EN 55022 The EUT received AC power source from the outlet socket under the turntable All
3. 5kHz Impulse Wave shape 5 50 ns Burst Duration 15 ms Burst Period 3 Hz Test Duration Not less than 1 min 8 5 2 TEST INSTRUMENT Immunity Shield Room Name of Equipment Manufacturer Mode e Serial Number Calibration Due ECAT Control Center KeyTek E Class Series 100 9502325 04 10 2010 Capacitor Clamp KeyTek CCL 4 9503290 Test S W E400 Burstware V4 19 c Note 1 The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML ROC and NIST USA 2 N C R No Calibration required 8 5 3 TEST PROCEDURE please refer to measurement standard or CCS SOP PA 024 a Both positive and negative polarity discharges were applied b The length of the hot wire from the coaxial output of the EFT generator to the terminals on the EUT should not exceed 1 meter c The duration time of each test sequential was 1 minute d The transient burst waveform was in accordance with IEC 61000 4 4 5 50ns Page 44 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 5 4 TEST SETUP 10cm AC Line Support EFT Burst Units Surge Generator Comm Line 3m 10cm AC Line Burst Generator Po Injection Clamp e For the actual test configuration please refer to the related item Photographs of the Test Configuratio
4. support equipment power received from another socket under the turntable The antenna was placed at 10 meter away from the EUT as stated in EN 55022 The antenna connected to the Spectrum Analyzer via a cable and at times a pre amplifier would be used The Analyzer Receiver quickly scanned from 30MHz to 1000MHz The EUT test program was started Emissions were scanned and measured rotating the EUT to 360 degrees and positioning the antenna 1 to 4 meters above the ground plane in both the vertical and the horizontal polarization to maximize the emission reading level The test mode s described in Item 3 1 were scanned during the preliminary test After the preliminary scan we found the test mode described in Item 3 1 producing the highest emission level The worst configuration of EUT and cable antenna position polarization and turntable position of the above highest emission levels were recorded for the final test Procedure of Final Test EUT and support equipment were set up on the turntable as per the configuration with highest emission level in the preliminary test The Analyzer Receiver scanned from 30MHz to 1000MHz Emissions were scanned and measured rotating the EUT to 360 degrees varying cable placement and positioning the antenna 1 to 4 meters above the ground plane in both the vertical and the horizontal polarization to maximize the emission reading level Recording at least the six highest emissions Emission fre
5. without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 4 3 TEST PROCEDURE please refer to measurement standard or CCS SOP PA 023 The test procedure was in accordance with IEC 61000 4 3 a The testing was performed in a fully anechoic chamber The transmit antenna was located at a distance of 3 meters from the EUT b The frequency range is swept from 80 MHz to 1000 MHz with the signal 80 amplitude modulated with a 1kHz sine wave The rate of sweep did not exceed 1 5 x 10 decade s where the frequency range is swept incrementally the step size was 1 of preceding frequency value C The dwell time at each frequency shall be not less than the time necessary for the EUT to be able to respond e The test was performed with the EUT exposed to both vertically and horizontally polarized fields on each of the four sides Page 41 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 4 4 TEST SETUP lt _ 3 meter 7X3x3 EUT amp Support Units 1 5 meter 0 8m pn n SS Power Amp e i EUT Monitoring by ea using a camera PC Controller to control S G amp PAas well as forward power Control Room e For the actual test configuration please refer to the related item Photographs of the Test Configur
6. 7 2 CONDUCTED EMISSION MEASUREMENT AT TELECOMMUNICATION PORTS 18 7 3 RADIATED EMISSION MEASUREMENT essesesseeeee nennen ener enne nnne nnns nennen rena 21 7 4 HARMONICS CURRENT MEASUREMENT sess eene enne nnne nennen nennen nnns nennen 26 7 5 VOLTAGE FLUCTUATION AND FLICKS MEASUREMENT sess 29 8 IMMUNITY TEST icri ede ra e i edat idet id ec dd ue td a ida dde lide 33 8 4 GENERALE DESCRIPTION Bhai ele Res ea ha i e cud a Cua S 33 8 2 GENERAL PERFORMANCE CRITERIA DESCRIPTION sse nennen nnns 34 8 3 ELECTROSTATIC DISCHARGE ESD ssssssssssssseee eene ener nnne nnne nns 35 8 4 RADIATED RADIO FREQUENCY ELECTROMAGNETIC FIELD RS ssesessssss 39 8 5 ELECTRICAL FAST TRANSIENT EFT eene nennen nnne nnne nns 44 8 6 SURGE IMMUNITY TES iie iere ene deed eie buie ua vede ordi ee edle EU e aer iUad 47 8 7 CONDUCTED RADIO FREQUENCY DISTURBANCES CS sss 50 8 8 POWER FREQUENCY MAGNETIC FIELD arnee EAE NE 55 8 9 VOLTAGE DIP amp VOLTAGE INTERRUPTIONS sse ennemis 58 Page 3 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 1 TEST CERTIFICATION Product AC DC Switching Adapter CP1220 12V 2A CP1215 12V 1 5A CP1210 12V 1A CP0920 9V 2A CP0910 9V 1A
7. DC Switching Adapter CP1220 Eddy Chung Remarks Temp 25 C Humidity 45 RH U 10096 0 04 1 0004 U 100 2 0004 Harmonic Emission IEC 61000 3 2 EN 61000 3 2 EN60555 2 2008 98 22 AM 5 17 1 Urme 299 V P 2960 W THC 022 A Rage 24 Ime 02601 A pf 0 494 V nom 230 V TestTime 5 min 100 CPIZ2 Test completed Result PASSED Temp 25 C Hometity 45 RH BAR IDEG DAC Re me Full Bar Actual Values Empty Bar Maximum Values Blue Current Green Voltage Red Failed Note According to clause 7 of IEC 61000 3 2 equipment with a rated power of 75W or less no limits apply Page 28 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 7 5 VOLTAGE FLUCTUATION AND FLICKS MEASUREMENT 7 5 1 LIMITS OF VOLTAGE FLUCTUATION AND FLICKS MEASUREMENT Testitom Limit Remak Oo Pa w R means short term flicker indicator B 065 a means long term flicker indicator Tams 590 a means maximum time that dt exceeds 3 96 dmax 96 4 MN means maximum relative voltage change dc 96 33 kc means relative steady state voltage change 7 5 2 TEST INSTRUMENTS Name of Equipment Manufacturer Model Serial Number Calibration Due P d EMC Partner HAR1000 1P 05 20 2010 Test S W HARCS Ver 4 16 NOTE The calibration interval of the a
8. Standard EC 61000 4 5 Combination Wave Wave Shape 1 2 50 us Open Circuit Voltage 8 20 us Short Circuit Current x AC Power Port line to line 1kV line to earth ground 2kV Test Voltage DC Power Port line to earth 0 5kV Signal Ports and Telecommunication Ports line to ground 1kV X AC Power Port L N L PE N PE DC Power Port L PE Signal Ports and Telecommunication Ports T to Ground R to Ground 2 ohm between networks 12 ohm between network and ground Polarity Positive Negative Phase Angle 0 90 180 270 Surge Input Output Generator Source Impedance Pulse Repetition Rate 1 time min maximum Number of Tests 5 positive and 5 negative at selected points 8 6 2 TEST INSTRUMENT Immunity Shield Room Name of Equipment Manufacturer Model Serial Number Calibration Due ECAT Control Center KeyTek E Class Series 100 9502325 04 10 2010 ExeimalcouplerrBMesdpler ae act CM TELCD 0104399 N CR For Telecom Lines YO Signal Line Coupler KeyTek CM I OCD 0103234 N CR Decoupler Test S W E500 Surgeware V4 19cc Note 1 The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML ROC and NIST USA 2 N C R No Calibration required Page 47 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 8082
9. during the setting process and with a disturbance signal of 80 amplitude The signal was modulated with a 1 kHz sine wave pausing to adjust the RF signal level or the switch coupling devices as necessary The sweep rate was 1 5 x 10 decades s Where the frequency range is swept incrementally the step size was 1 of preceding frequency value from 150 kHz to 80 MHz The dwell time at each frequency was less than the time necessary for the EUT to be exercised and able to respond Sensitive frequencies such as clock frequency ies and harmonics or frequencies of dominant interest was analyzed separately Attempts was made to fully exercise the EUT during testing and to fully interrogate all exercise modes selected for susceptibility Page 52 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 7 4 TEST SETUP 0 5 m 01m L 03M Balanced pair Mains Mains re CDN M2 M3 T 112 5 Boro x 1 ana LI Unscreened multi wire cable Um SUIS KRISS i 1 Insulation is EM Injection Clamp m optional p Qe I I t ee ow eed i I I Ground Reference Plane 1 1 J E i Test generator I NOTE T2 Fixed attenuator 6 db Note 1 The EUT is setup 0 1m above Ground Reference Pla
10. y reading reading factor result result limit limit margin margin Remark dBuV dBuV dB dBuV dBuV dBuV dBuV dB dB 1 0 1550 58 80 46 80 0 20 59 00 47 00 65 73 55 73 6 73 8 73 Pass 2 0 2400 50 66 42 56 0 14 50 80 42 70 62 10 52 10 11 30 9 40 Pass 3 0 3000 28 08 12 38 0 12 28 20 12 50 60 24 50 24 32 04 37 74 Pass 4 0 3900 33 82 19 02 0 08 33 90 19 10 58 06 48 06 24 16 28 96 Pass 5 0 8000 35 37 31 17 0 03 35 40 31 20 56 00 46 00 20 60 14 80 Pass 6 1 7550 37 27 28 07 0 03 37 30 28 10 56 00 46 00 18 70 17 90 Pass REMARKS L1 Line One Live Line Page 16 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E Job No 80820002 Date 2009 8 21 Company Coming Data Co Ltd Time F 07 32 45 Standard EN55022 Class B Conduction QP Temp C Hum 22 C 45 Test item Conduction test Test By Jerry Lin Line L2 Test Voltage AC 230V 50Hz Model CP1220 Test Mode Mode 1 80 0 dBuV QP AVG 1 amp 0 150 0 5 MHz 5 30 000 F QuasiPeak Average Correction QuasiPeak Average QuasiPeak Average QuasiPeak Average requency D RP h No MHz reading reading factor result result limit limit margin margin Remark dBuV dBuV dB dBuV dBuV dB
11. 0002 E 8 6 3 TEST PROCEDURE please refer to measurement standard or CCS SOP PA 025 a For EUT power supply The surge is applied to the EUT power supply terminals via the capacitive coupling network Decoupling networks are required in order to avoid possible adverse effects on equipment not under test that may be powered by the same lines and to provide sufficient decoupling impedance to the surge wave The power cord between the EUT and the coupling decoupling networks was shorter than 2 meters in length b For test applied to unshielded un symmetrically operated interconnection lines of EUT The surge was applied to the lines via the capacitive coupling The coupling decoupling networks didn t influence the specified functional conditions of the EUT The interconnection line between the EUT and the coupling decoupling networks was shorter than 2 meters in length C For test applied to unshielded symmetrically operated interconnection telecommunication lines of EUT The surge was applied to the lines via gas arrestors coupling Test levels below the ignition point of the coupling arrestor were not specified The interconnection line between the EUT and the coupling decoupling networks was shorter than 2 meters in length 8 6 4 TEST SETUP To AC Source Surge Immunity EUT amp Support Units Controller Computer e For the actual test configuration please refer to the related item Photographs of the Test Configu
12. 5 DATA SAMPLE F QuasiPeak Average Correctrion QuasiPeak Average QuasiPeak Average QuasiPeak Average hid di di fact It It limit limit reading reading actor resu resu imi imi margin margin dBuV dBuV dB dBuV dBuV dBuV dBuV dB dB 43 95 95 33 00 00 1000 43 00 56 00 00 46 00 00 2 205 Frequency MHz Emission frequency in MHz Reading dBuV Uncorrected Analyzer Receiver reading Insertion loss of LISN if it gt 0 5 dB Correction Factor dB LISN Factor Cable loss Result dBuV Raw reading converted to dBuV and CF added Limit dBuV Limit stated in standard Margin dB Result dBuV Limit dBuV Page 15 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc 7 1 6 TEST RESULTS Report No 80820002 E Job No 80820002 Date 2009 8 21 Company Coming Data Co Ltd Time PM 07 25 43 Standard EN55022 Class B Conduction QP Temp C Hum 22 C 45 Test item Conduction test Test By Jerry Lin Line L1 Test Voltage AC 230V 50Hz Model CP1220 Test Mode Mode 1 80 0 dBuV QP AVG 4 amp 5 i 0 150 0 5 MHz 5 30 000 Fregiene QuasiPeak Average Correction QuasiPeak Average QuasiPeak Average QuasiPeak Average No MHZ
13. Compliance Certification Services Inc Report No 80820002 E CE EMC TEST REPORT for AC DC Switching Adapter MODEL CP1220 CP1215 CP1210 CP0920 CP0910 CP0630 CP0620 CP0610 CP0540 CP0530 CP0520 CP0510 CP050085 Test Report Number 80820002 E Issued for Coming Data Co Ltd 5F 1 No13 WU CHUNG 1 RD HSIN CHUNG CITY TAIPEI HSIEN TAIWAN R O C Issued By Compliance Certification Services Inc Wugu Laboratory No 11 Wu Gong 6 Rd Wugu Industrial Park Taipei Hsien 248 Taiwan R O C TEL 886 2 2299 9720 FAX 886 2 2299 9721 E Mail service tw ccsemc com Issued Date August 26 2009 TAF wha S AN K NM A et e ign ACCREDITED Lali aW Voting Lenny TESTING CERT 0824 01 1309 Note This report shall not be reproduced except in full without the written approval of Compliance Certification Services Inc This document may be altered or revised by Compliance Certification Services Inc personnel only and shall be noted in the revision section of the document The client should not use it to claim product endorsement by TAF A2LA NIST or any government agencies The test results in the report only apply to the tested sample Page 1 69 Compliance Certification Services Inc Report No 80820002 E Revision History Issue aH RI EI o7 mee oo August 26 2009 nitia Initial Issue Angel Cheng Cheng Page 2 This report shall not be reproduced exc
14. No 80820002 E Job No 80820002 Ant Polar Ver Standard EN 55022 Class B Tested Distance 10m Test Item Radiated Emission Date 2009 8 22 Temp C Hum RH 25 C 56 RH Time PM 07 42 Company Coming Data Co Ltd Tested By Stan Lin Model CP1220 dBuV m 70 0 60 0 50 0 S 400 ed LLLA ca D LLL a wl t Tl x x dl 1 i T 0 0 1 i i i 1 i i i aR DPE 30 50 100 200 300 400 500 600 700 800 1000 Frequency MHz No Frequency Reading Correction Result Limit Margin Degree Height Remark MHz dBuV Factor dB m dBuV m dBuV m dB cm 1 38 46 11 58 15 02 26 60 30 00 3 40 339 60 100 00 QP 2 47 79 16 79 10 01 26 80 30 00 3 20 0 00 100 00 QP 3 58 41 15 52 7 68 23 20 30 00 6 80 351 00 100 00 QP 4 69 27 16 00 7 60 23 60 30 00 6 40 84 00 100 00 QP 5 86 83 16 76 10 24 27 00 30 00 3 00 296 40 100 00 QP 6 120 68 10 00 15 00 25 00 30 00 5 00 1 10 100 00 QP 7 151 13 7 94 13 46 21 40 30 00 8 60 1 90 100 00 QP Note The other emission levels were very low against the limit Page 24 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc CCS Radiated Test OATS 1 Report No 80820002 E Job No 80820002 Ant Polar Hor Standard EN 55022 Class B Tested Distance 10m Test Item Radiated Em
15. O Controller Computer e For the actual test configuration please refer to the related item Photographs of the Test Configuration 8 9 5 TEST RESULTS Temperature 2 C Humidity 42 RH Pressure 1010mbar Tested by Eddy Cheng Required Passing Criterion B gt 95 reduction 0 5 period Performance Criterion C 30 reduction 25 period amp gt 95 reduction 250 period Test Power 230Vac 50Hz ra Note 1 There was no change compared with initial operation during and after the test No unintentional response was found during the test Page 59 This report shall not be reproduced except in full without the written approval of Compliance Certification Services
16. Support 0 5 mm Thick EUT lat units Naap 470KQ L5 NN Po O 7 Wooden Table 470 kQ B e For the actual test configuration please refer to the related item Photographs of the Test Configuration Ground Reference Plane NOTE TABLE TOP EQUIPMENT The configuration consisted of a wooden table 0 8 meters high standing on the Ground Reference Plane The GRP consisted of a sheet of aluminum at least 0 25mm thick and 2 5 meters square connected to the protective grounding system A Horizontal Coupling Plane 1 6m x 0 8m was placed on the table and attached to the GRP by means of a cable with 940k total impedance The equipment under test was installed in a representative system as described in section 7 of IEC 61000 4 2 and its cables were placed on the HCP and isolated by an insulating support of 0 5mm thickness A distance of 1 meter minimum was provided between the EUT and the walls of the laboratory and any other metallic structure FLOOR STANDING EQUIPMENT The equipment under test was installed in a representative system as described in section 7 of IEC 61000 4 2 and its cables were isolated from the Ground Reference Plane by an insulating support of 0 1 meter thickness The GRP consisted of a sheet of aluminum that is at least 0 25mm thick and 2 5 meters square connected to the protective grounding system and extended at least 0 5 meters from the EUT on all sides Page 37 This report shall not be reproduced except
17. V 1A 6V 1A CP0540 5V 4A 5V 4A CP0530 5V 3A 5V 3A CP0520 5V 2A 5V 2A CP0510 5V 1A 5V 1A CP050085 5V 0 85A 5V 0 85A Page 6 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E I O PORT I O PORT TYPES Q TY TESTED WITH N A Page 7 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 4 TEST METHODOLOGY 4 1 DECISION OF FINAL TEST MODE 1 The following test mode was scanned during the preliminary test Pre Test Mode Mode 1 CP1220 Full Load Mode 2 CP0920_Full Load Mode 3 CP0540_Full Load 2 After the preliminary scan the following test mode was found to produce the highest emission level Final Test Mode Conducted Emission Mode 1 Emission Radiated Emission Mode 1 Immunity Mode 1 Then the above highest emission mode of the configuration of the EUT and cable was chosen for all final test items 4 2 EUT SYSTEM OPERATION 1 EUT Power on 2 Connection load The definite output voltage electric current is whether normal 3 Start the test Note Test program is self repeating throughout the test Page 8 This report shall not be reproduced excep
18. alibration interval of the above test instruments is 12 months and the calibrations are traceable to NML ROC and NIST USA Page 13 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 7 1 3 TEST PROCEDURES please refer to measurement standard or CCS SOP PA 031 Procedure of Preliminary Test The EUT and support equipment if needed were set up as per the test configuration to simulate typical usage per the user s manual When the EUT is a tabletop system a wooden table with a height of 0 8 meters is used and is placed on the ground plane as per EN 55022 see Test Facility for the dimensions of the ground plane used When the EUT is a floor standing equipment it is placed on the ground plane which has a 3 12 mm non conductive covering to insulate the EUT from the ground plane All I O cables were positioned to simulate typical actual usage as per EN 55022 The EUT installed by AC main power through a Line Impedance Stabilization Network LISN which was supplied power source and was grounded to the ground plane All support equipment power by a second LISN The test program of the EUT was started Emissions were measured on each current carrying line of the EUT using an EMI Test Receiver connected to the LISN powering the EUT The Receiver scanned from 150kHz to 30MHz for emissions in each of the
19. and coupling planes The EUT shall be exposed to at least 200 discharges 100 each at negative and positive polarity at a minimum of four test points One of the test points shall be subjected to at least 50 indirect discharges to the center of the front edge of the Horizontal Coupling Plane HCP The remaining three test points shall each receive at least 50 direct contact discharges If no direct contact test points are available then at least 200 indirect discharges shall be applied in the indirect mode Test shall be performed at a maximum repetition rate of one discharge per second Air discharges at slots and apertures and insulating surfaces On those parts of the EUT where it is not possible to perform contact discharge testing the equipment should be investigated to identify user accessible points where breakdown may occur Such points are tested using the air discharge method This investigation should be restricted to those area normally handled by the user A minimum of 10 single air discharges shall be applied to the selected test point for each such area The basic test procedure was in accordance with IEC 61000 4 2 a b ao 2 Q The EUT was located 0 1 m minimum from all side of the HCP dimensions 1 6m x 0 8m The support units were located another table 30 cm away from the EUT but direct support unit was were located at same location as EUT on the HCP and keep at a distance of 10 cm with EUT T
20. ation NOTE TABLETOP EQUIPMENT The EUT installed in a representative system as described in section 7 of IEC 61000 4 3 was placed ona non conductive table 0 8 meters in height The system under test was connected to the power and signal wire according to relevant installation instructions FLOOR STANDING EQUIPMENT The EUT installed in a representative system as described in section 7 of IEC 61000 4 3 was placed ona non conductive wood support 0 1 meters in height The system under test was connected to the power and signal wire according to relevant installation instructions Page 42 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 4 5 TEST RESULTS Temperature 24 C Humidity 48 RH Tested by Eddy Chung Required Passing Performance MEC REC a ELI Note 1 There was no change compared with the initial operation during the test Page 43 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 5 ELECTRICAL FAST TRANSIENT EFT 8 5 1 TEST SPECIFICATION Basic Standard EC 61000 4 4 X AC Power Port 1kV Test Voltage DC Power Port 0 5kV Signal Ports and Telecommunication Ports 0 5kV Polarity Positive amp Negative Impulse Frequency
21. bove test instruments is 12 months and the calibrations are traceable to NML ROC and NIST USA Page 29 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 7 5 3 TEST PROCEDURE please refer to measurement standard or CCS SOP PA 030 e The EUT was placed on the top of a wooden table 0 8 meters above the ground and operated to produce the most unfavorable sequence of voltage changes under normal operating conditions e During the flick measurement the measure time shall include that part of whole operation cycle in which the EUT produce the most unfavorable sequence of voltage changes The observation period for short term flicker indicator is 10 minutes and the observation period for long term flicker indicator is 2 hours 7 5 4 TEST SETUP Harmonics amp Flicker Analyzer Power Source Power Cord e For the actual test configuration please refer to the related item Photographs of the Test Configuration Page 30 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 7 5 5 TEST RESULTS Environmental Conditions 25deg C 55 RH Tested by Eddy Cheng Test Parameter Measurement Value Limit Remark Ta ms 0 500 PASS dc 0 110 3 3 PASS Note dma
22. ction is allowed below a performance level specified by the manufacturer when the equipment is used as intended The performance level may be replaced by a permissible loss of performance If the manufacturer does not specify the minimum performance level or the permissible performance loss then either of these may be derived from the product description and documentation and by what the user may reasonably expect from the equipment if used as intended After test the equipment shell continues to operate as intended without operator intervention No degradation of performance or loss of function is allowed after the application of the phenomenon below a performance level specified by the manufacturer when the equipment is used as intended The performance level may be replaced by a permissible loss of performance During the test degradation of performance is however allowed However no change of operating state if stored data is allowed to persist after the test If the minimum performance level or the permissible performance loss is not specified by the manufacturer then either of these may be derived from the product description and documentation and by what the user may reasonably expect from the equipment if used as intended Loss of function is allowed provided the functions is self recoverable or can be restored by the operation of controls by the user in accordance with the manufacturer instructions Functions and or infor
23. current n A n A Odd harmonics Odd Harmonics only 3 2 30 3 3 4 2 30 5 1 14 5 1 9 1 14 7 0 77 7 1 0 0 77 9 0 40 9 0 5 0 40 11 0 33 11 0 35 0 33 13 0 21 13 0 30 0 21 15 lt n lt 39 0 15x15 n 15 lt n lt 39 3 85 n 0 15x15 n Even harmonics 2 1 08 4 0 43 6 0 30 8 lt n lt 40 0 23x8 n Note 1 Class A and Class D are classified according to item 7 4 3 2 According to section 7 of EN 61000 3 2 the above limits for all equipment except for lighting equipment having an active input power gt 75 W and no limits apply for equipment with an active input power up to and including 75 W 7 4 2 TEST INSTRUMENTS Name of Equipment Manufacturer Model Serial Number Calibration Due dL EMC Partner HAR1000 1P 05 20 2010 TetS W O TetS W O HARCS Ver 4 16 NOTE The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML ROC and NIST USA Page 26 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 7 4 3 TEST PROCEDURE please refer to measurement standard or CCS SOP PA 029 The EUT was placed on the top of a wooden table 0 8 meters above the ground and operated to produce the maximum harmonic components under normal operating conditions for each successive harmonic component in turn The classification of EUT is according t
24. ept in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E TABLE OF CONTENTS 1 unscukeizisdaleem 4 2 TEST RESULT SUMMARY sssssssssssseeeee nennen enne nnne innen eren teer sientes nente DAAE ARE AE AAEN AAR nnns 5 3 EUT DESCRIPTION mr dies 6 4 TEST METHODOLOGY pikiren ted m pee tar o Reeves pede ua Ane a ddan en oer de Eo eacus 8 4 1 DECISION OF FINAL TEST MODE sessssseeeseeerenen eene enne nennen nennen nennen nennen nr nens 8 4 2 EUT SYSTEM OPERATION tt ente ea een i e E De ga o zi aide anaes 8 5 SETUP OF EQUIPMENT UNDER TEST tenete dese deo ed dad Le Fides nea ae d d ei d 9 5 1 DESCRIPTION OF SUPPORT UNITS sese nn nnne 9 5 2 CONFIGURATION OF SYSTEM UNDER TEST sees ener enne nnns en nnns 10 6 FACILITIES AND ACCREDITATIONS esses enne nn nere nnne enne 11 61 FACILITIES 2i tete et a ed e edd een ed d a qn dd a Pan led 11 6 2 ACCREDITATIONS esiisa aE eectese d ee e trae deer d eee ord eu e appe e Meere ee up e cee pe see excu ped AEAEE 11 6 3 MEASUREMENT UNCERTAINTY 5 hatt eret ce kc e ac d e t i a eg d devote 12 7 EMISSION TEST eite eret eene kae aka me neu aen n ne mana mul ex nsn re rera bu 13 7 1 CONDUCTED EMISSION MEASUREMENT sssesseseeeeneeee nennen enne nennen rennes 13
25. es Inc Report No 80820002 E 8 9 VOLTAGE DIP amp VOLTAGE INTERRUPTIONS 8 9 1 TEST SPECIFICATION Basic Standard EC 61000 4 11 Test duration time Minimum three test events in sequence Interval between event Minimum 10 seconds Angle 0 360 degree Step 45 degree 8 9 2 TEST INSTRUMENT Immunity shielded room Name of Equipment of Name of Equipment Manufacturer Manufacturer Mode Serial Number Calibration Due TestSwW O S W WinPATS V 3 26 a The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML ROC and NIST USA Dips Interruption and Variations Simulator Haefely Trench PLINE 1610 081568 06 08 05 2010 8 9 3 TEST PROCEDURE please refer to measurement standard or CCS SOP PA 028 a The EUT and support units were located on a wooden table 0 8 m away from ground floor b Setting the parameter of tests and then perform the test software of test simulator c Conditions changes to occur at 0 degree crossover point of the voltage waveform d Recording the test result in test record form e Removes the AC DC Switching Adapter to test if any Page 58 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 9 4 TEST SETUP SS Dips Interruption EUT and Variations amp i Simulator Support Units Pe
26. he time interval between two successive single discharges was at least 1 second Contact discharges were applied to the non insulating coating with the pointed tip of the generator penetrating the coating and contacting the conducting substrate Air discharges were applied with the round discharge tip of the discharge electrode approaching the EUT as fast as possible without causing mechanical damage to touch the EUT After each discharge the ESD generator was removed from the EUT and re triggered for a new single discharge The test was repeated until all discharges were complete At least ten single discharges in the most sensitive polarity were applied at the front edge of each HCP opposite the center point of each unit of the EUT and 0 1 meters from the front of the EUT The long axis of the discharge electrode was in the plane of the HCP and perpendicular to its front edge during the discharge At least ten single discharges in the most sensitive polarity were applied to the center of one vertical edge of the Vertical Coupling Plane VCP in sufficiently different positions that the four faces of the EUT were completely illuminated The VCP dimensions 0 5m x 0 5m was placed vertically to and 0 1 meters from the EUT Page 36 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 3 4 TEST SETUP
27. iewed by p P f Fi Ging lo Jy eX Loc Rex Lai Amanda Wu Section Manager Section Manager Page 4 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 2 TEST RESULT SUMMARY EMISSION Standard Item Result Remarks Conducted Main Port PASS Meet Class B limit EN 55022 2006 A1 2007 Conducted Telecom port Meet Class B limit Radiated Meet Class B limit EN 61000 3 2 2006 Harmonic current emissions Meet Class A limit EN 61000 3 3 2008 Voltage fluctuations amp flicker Meets the requirements IMMUNITY EN 55024 1998 A1 2001 A2 2003 Standard Item Result Remarks IEC 61000 4 2 1995 A1 1998 A2 2000 IEC 61000 4 3 2006 ESD PASS Meets the requirements of Performance Criterion B PASS eets the requirements of Performance Criterion A R IEC 61000 4 4 2004 PASS Meets the requirements of Performance Criterion B S F IEC 61000 4 5 2005 PASS Meets the requirements of Performance Criterion B IEC 61000 4 6 2006 PASS Meets the requirements of Performance Criterion A IEC 61000 4 8 1993 A1 2000 PFMF PASS Meets the requirements of Performance Criterion A variations oltage Interruptions 1 gt 95 reduction Performance Criterion C Note 1 The test result judgment is decided by the limit of test standard 2 The information of measurement uncertainty
28. in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No B0820002 E 8 3 5 TEST RESULTS Air Discharge Test Levels Performance Performance Performance CIB KIA Test Levels Performance Performance Criterion Criterion T please refer to attached page Blue arrow mark for Contact Discharge and red arrow mark for Air c For the tested points to E Discharge Discharge To Horizontal Coupling Plane 2kV 4kV 8kV Pass Fail Performance Criterion Observation Front D g 0o K 0O XA UB Notei Back xX xX L1 xX L1 KIA LIB Note 1 left Dx x Oo mW D Ka LB j Nt i LH Ka LiB Noti Note 1 There was no change compared with initial operation during the test 2 NDP Means that no discharge point had been occurred during that particular coupling method Page 38 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 4 RADIATED RADIO FREQUENCY ELECTROMAGNETIC FIELD RS 8 4 1 TEST SPECIFICATION Basic Standard Frequency Range Field Strength Modulation Frequency Step Polarity of Antenna Test Distance Antenna Height IEC 61000 4 3 80 MHz 1000 MHz 3 V m 1kHz Sine Wave 80 AM Modulation 1 of preceding frequency value Horizontal and Vertical 3m 1 5
29. is available upon the customer s request Meets the requirements of Voltage oltage Dips dips amp 1 gt 95 reduction Performance Criterion B EG 51000 4711 2004 voltage PASS 2 30 reduction Performance Criterion C Page 5 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 3 EUT DESCRIPTION Product AC DC Switching Adapter Brand Name Coming Data CP1220 12V 2A CP1215 12V 1 5A CP1210 12V 1A CP0920 9V 2A CP0910 9V 1A Model CP0630 6V 3A CP0620 6V 2A CP0610 6V 1A CP0540 5V 4A CP0530 5V 3A CP0520 5V 2A CP0510 5V 1A CP050085 5V 0 85A Applicant Coming Data Co Ltd Housing material Plastic Serial Number 80820002 Received Date August 20 2009 I P 230 50Hz EUT Power Raung O P List as below AC Power Cord Type N A Wall mounted Remark 1 All the above models are identical except for the designation of model numbers and ampere 2 Client consigns only one sample to test model number CP1220 12V 2A Therefore the testing Lab just guarantees the unit which has been tested Model Voltage Ampere CP1220 12V 2A 12V 2A CP1215 12V 1 5A 12V 1 5A CP1210 12V 1A 12V 1A CP0920 9V 2A 9V 2A CP0910 9V 1A 9V 1A CP0630 6V 3A 6V 3A CP0620 6V 2A 6V 2A CP0610 6
30. ission Date 2009 8 22 Temp C Hum RH 25 C 56 RH Time PM 07 47 Company Coming Data Co Ltd Tested By Stan Lin Model CP1220 dBuV m 70 0 60 0 50 0 S 40 0 tala sss Ey 30 0 P N E E E 20 0 w 1 LL a T Tf 0 0 1 1 1 1 1 1 1 1 1 TI 30 50 100 200 300 400 500 600 700800 1000 Frequency MHz No Frequency Reading Correction Result Limit Margin Degree Height Remark MHz dBuV Factor dB m dBuV m dBuV m dB cm 1 39 00 8 12 14 68 22 80 30 00 7 20 339 80 400 00 QP 2 68 60 15 82 7 58 23 40 30 00 6 60 308 70 400 00 QP 3 80 69 13 36 8 84 22 20 30 00 7 80 145 40 400 00 QP 4 137 47 7 03 13 97 21 00 30 00 9 00 225 90 400 00 QP 5 175 89 6 30 12 70 19 00 30 00 11 00 165 40 400 00 QP 6 208 09 6 15 12 85 19 00 30 00 11 00 202 90 400 00 QP Note The other emission levels were very low against the limit Page 25 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 7 4 HARMONICS CURRENT MEASUREMENT 7 4 1 LIMITS OF HARMONICS CURRENT MEASUREMENT Limits for Class A equipment Limits for Class D equipment Harmonics Max permissible Harmonics Max permissible harmonics Max permissible Order harmonics current Order current per watt mA W harmonics
31. m Page 39 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 4 2 TEST INSTRUMENT RS Chamber Name of Equipment Manufacturer Modea Serial Number Calibration Due Pulse Generator Agilent 81101A DE41B01423 06 11 2010 Signal Generator 250kHz 40GHz Agilent E8257C US42340383 07 18 2010 500 Watt 10kHz Amplifier 500A100A 300299 N C R Amplifier Research 500 Watts 80 1 000MHz Amplifier 500W 1000A 320994 N C R Amplifier Research 250 Watts 1 2 5GHz Amplifier 250T1G3M1 320245 N C R Amplifier Research 300 Watts 2 5 7 5GHz Amplifier 300T2G8M1 320255 N C R Amplifier Research 250 Watts 7 5 18GHz Amplifier 250T8G18M1 320246 N C R Amplifier Research RF Test System Controller Amplifier SC1000M3 306666 Research Power Meter Boonton 4232A 01 02 09 15 2010 Bi log Antenna SCHWAZBECK VULB9166 9166 1093 N C R Log Periodic Antenna tbid AT1080 306709 Horn SCHWAZBECK BBHA 9120D 530 N C R Field Probe 3M 18GHz EE FP7018 311430 05 21 2010 P4 ooon Resear OC8HE04 DA paaa Reach POTMA Antenna Tower Amplifier TP2000 N A N C R Research cee rm S106 Note 1 The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML ROC and NIST USA 2 N C R No Calibration required Page 40 This report shall not be reproduced except in full
32. mation stored in non volatile memory or protected by a battery backup shall not be lost Page 34 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 3 ELECTROSTATIC DISCHARGE ESD 8 3 1 TEST SPECIFICATION Basic Standard IEC 61000 4 2 Discharge Impedance 330 ohm 150 pF Air Discharge 2 4 8 kV Direct Contact Discharge 2 4 kV Direct Indirect Polarity Positive amp Negative Air Discharge min 10 times at single test point for Number of Discharge each negative and positive polarity Contact Discharge min 200 times in total Single Discharge 1 second minimum Discharge Voltage Discharge Mode 8 3 2 TEST INSTRUMENT IMMUNITY SHIELDED ROOM Name of Equipment Manufacturer Mode Serial Number Calibration Due ESD Simulator ESS 2002 ESS0463036 07 25 2010 Note The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML ROC and NIST USA Page 35 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 3 3 TEST PROCEDURE please refer to measurement standard or CCS SOP PA 022 The discharges shall be applied in two ways a o Contact discharges to the conductive surfaces
33. n NOTE TABLETOP EQUIPMENT The configuration consisted of a wooden table 0 8m high standing on the Ground Reference Plane The GRP consisted of a sheet of aluminum at least 0 25mm thick and 2 5m square connected to the protective grounding system A minimum distance of 0 5m was provided between the EUT and the walls of the laboratory or any other metallic structure FLOOR STANDING EQUIPMENT The EUT installed in a representative system as described in section 7 of IEC 61000 4 4 and its cables were isolated from the Ground Reference Plane by an insulating support that is 0 1 meter thick The GRP consisted of a sheet of aluminum at least 0 25mm thick and 2 5m square connected to the protective grounding system Page 45 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 5 5 TEST RESULTS Pressure f1011mbar Tested by Eddy Chung Test Level Performance Test Point Polarity kV Criterion Observation Result L 1 XA LIB Note 1 PASS L N 1 XA LIB Note 1 PASS Note 1 There was no change compared with initial operation during the test Page 46 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 6 SURGE IMMUNITY TEST 8 6 1 TEST SPECIFICATION Basic
34. ne 2 The CDNs and or EM clamp used for real test depends on ports and cables configuration of EUT e For the actual test configuration please refer to the related item Photographs of the Test Configuration NOTE TABLE TOP AND FLOOR STANDING EQUIPMENT The equipment to be tested was placed on an insulating support of 0 1 meters height above a ground reference plane All relevant cables shall be provided with the appropriate coupling and decoupling devices at a distance between 0 1 meters and 0 3 meters from the projected geometry of the EUT on the ground reference plane Page 53 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 7 5 TEST RESULTS Pressure 1010mbar ested by Eddy Chung Frequency Band Field Strength Cable Injection Performance MHz Vrms Method Criterion 0 15 80 3 Power Line CDN M3 XA B Note 1 PASS Note 1 There was no change compared with initial operation during the test Observation Result Page 54 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 8 POWER FREQUENCY MAGNETIC FIELD 8 8 1 TEST SPECIFICATION Basic Standard IEC 61000 4 8 Frequency Range 50Hz Field Strength 1A m Observation Time 1 minute Induc
35. ng Network Communications Inc vigi e Sane o FE sana FCC 801 T4 03017 09 21 2010 Decoupling Network Communications Inc Fischer Custom EM Injection Clamp F 203l 28mm 09 21 2010 Passive Impedance Fischer Custom FCC 801 150 50 CDN 03053803054 09 21 2010 Adapters Communications Inc Calibration Fixture Fischer Custom F 203l CF 23mm 408 09 21 2010 Communications Inc Sana ne Coupling Peur E om FCC 801 T8 RJ45 04024 09 21 2010 Decoupling Network Communications Inc Attenuator Amplifier Research HFP 575 3 6 NM NF201875106 N C R Amplifier Research DC2600A 306621 Test S W SW1005 Release 1 4 Note 1 The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML ROC and NIST USA 2 N C R No Calibration required Page 51 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 7 3 TEST PROCEDURE please refer to measurement standard or CCS SOP PA 026 The EUT shall be tested within its intended operating and climatic conditions The test shell performed with the test generator connected to each of the coupling and decoupling devices in turn while the other non excited RF input ports of the coupling devices are terminated by a 50 ohm load resistor The frequency range was swept from 150 kHz to 80 MHz using the signal level established
36. o Frequency Electromagnetic Field Susceptibility Test RS EG 00 86 4000 MHz 3V m 80 AM 1kHz Performance Criterion A Electrical Fast Transient Burst EFT AC Power Port 1kV me Power Port 0 5kV Signal Ports and Telecommunication Ports 0 5kV Performance Criterion B Surge Immunity Test 1 2 50 us Open Circuit Voltage 8 20 us Short Circuit Current Basic Standard EC 61000 4 5 ipd Port line to line 1kV line to earth ground iion and DC Power Port line to earth 0 5kV b e MU Mes Signal Ports and Telecommunication Ports line to ground 1kV Criterion required Performance Criterion B Product Standard Conducted Radio Frequency Disturbances Test IEC 61000 4 6 CS 0 15 80 MHz 3Vrms 80 AM 1kHz Performance Criterion A Power frequency magnetic field immunity test Performance Criterion A oltage Dips i gt 95 reduction for 0 5 period Performance Criterion B ii 3096 reduction for 25 period ee E Eel nA Genn oltage Interruptions gt 95 reduction for 250 period Performance Criterion C Page 33 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 2 GENERAL PERFORMANCE CRITERIA DESCRIPTION Criteria A Criteria B Criteria C The equipment shell continues to operate as intended without operator intervention No degradation of performance or loss of fun
37. o section 5 of EN 61000 3 2 The EUT is classified as follows Class A Balanced three phase equipment Household appliances excluding equipment as Class D Tools excluding portable tools Dimmers for incandescent lamps audio equipment equipment not specified in one of the three other classes Class B Portable tools Arc welding equipment which is not professional equipment Class C Lighting equipment Class D Equipment having a specified power less than or equal to 600 W of the following types Personal computers and personal computer monitors and television receivers The correspondent test program of test instrument to measure the current harmonics emanated from EUT is chosen The measure time shall be not less than the time necessary for the EUT to be exercised 7 4 4 TEST SETUP Harmonics amp Flicker Analyzer Power Power Cord For the actual test configuration please refer to the related item Photographs of the Test Configuration Page 27 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 7 4 5 TEST RESULTS Power Consumption 2960N fest Results PASS Environmental Conditions 23deg C 4596 RH Limits Class RAOBoOCOD Test Mode Mode1 fested by Eddy Chung Harmonic Emission IEC 61000 3 2 EN 61000 3 2 EN60555 2 Comply IEC 61000 3 2 Ed 3 0 IEC 61000 4 7 Ed 2 0 AC
38. of the Test Configuration NOTE TABLETOP EQUIPMENT The equipment shall be subjected to the test magnetic field by using the induction coil of standard dimension 1m x 1 m The induction coil shall then be rotated by 90 degrees in order to expose the EUT to the test field with different orientations FLOOR STANDING EQUIPMENT The equipment shall be subjected to the test magnetic field by using induction coils of suitable dimensions The test shall be repeated by moving and shifting the induction coils in order to test the whole volume of the EUT for each orthogonal direction The test shall be repeated with the coil shifted to different positions along the side of the EUT in steps corresponding to 50 96 of the shortest side of the coil The induction coil shall then be rotated by 90 degrees in order to expose the EUT to the test field with different orientations Page 56 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 8 5 TEST RESULTS Field Strength Performance Obsen ation Results Alm Criterion X 1 KIA CIB Note 1 Pass MA OB Z 1 KA CIB Note 1 Pass Note 1 There was no change compared with the initial operation during the test Page 57 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Servic
39. quency amplitude antenna position polarization and turntable position were recorded into a computer in which correction factors were used to calculate the emission level and compare reading to the applicable limit and only Q P reading is presented The test data of the worst case condition s was recorded Page 22 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 7 3 4 TEST SETUP Test table amp Turntable 1m 4m f Coaxial Cabld Power Cable Ground Plane EMI Receiver e For the actual test configuration please refer to the related item Photographs of the Test Configuration 7 3 5 DATA SAMPLE Correction Frequency Reading Factor Result Limit Margin ES Height Reman MHz dBuV dB m EN dBuV m dB cm Frequency MHz Emission frequency in MHz Reading dBuV Uncorrected Analyzer Receiver reading Correction Factor dB m Antenna factor Cable loss Amplifier gain Result dBuV m Reading dBuV Corr Factor dB m Limit dBuV m Limit stated in standard Margin dB Result dBuV m Limit dBuV m Q P Quasi Peak Page 23 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc 7 3 6 TEST RESULTS CCS Radiated Test OATS 1 Report
40. ration Page 48 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 6 5 TEST RESULTS Pressure f010mbar ested by Eddy Cheng Required Passing Performance Criterion B Test Point B cu b EROR Result Page 49 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 7 CONDUCTED RADIO FREQUENCY DISTURBANCES CS 8 7 1 TEST SPECIFICATION Basic Standard Frequency Range Field Strength Modulation Frequency Step Coupled cable Coupling device IEC 61000 4 6 0 15 MHz 80 MHz 3 Vrms 1kHz Sine Wave 80 AM Modulation 1 of preceding frequency value Power Mains Unshielded gt lt CDN M2 2 wires L CDN M3 3 wires L CDN T2 for Line LC CDN TA T8 for LAN Page 50 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 7 2 TEST INSTRUMENT Immunity Shield Room Name of Equipment Manufacturer Model Serial Number Calibration Due eae tec Power Line Coupling Fischer Custom FCC 801 M3 16A 09 21 2010 Decoupling Network Communications Inc Stave COUP Fischer ueram FCC 801 T2 03016 09 21 2010 Decoupli
41. structed in conformance with the requirements of ANSI C63 4 and CISPR Publication 22 All receiving equipment conforms to CISPR 16 1 1 CISPR 16 1 2 CISPR 16 1 3 CISPR 16 1 4 CISPR 16 1 5 6 2 ACCREDITATIONS Our laboratories are accredited and approved by the following approval agencies according to ISO IEC 17025 USA FCC A2LA Canada INDUSTRY CANADA Taiwan TAF NCC Copies of granted accreditation certificates are available for downloading from our web site http www ccsemc com Page 11 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 6 3 MEASUREMENT UNCERTAINTY Where relevant the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16 4 2 Conducted emissions 9kHz 30MHz 2 81dB 30 200MHz 3 88 dB Radiated emissions 1 200 1000MHz 3 87 dB This uncertainty represents an expanded uncertainty expressed at approximately the 95 confidence level using a coverage factor of k 2 Consistent with industry standard e g CISPR 22 2006 clause 11 Measurement Uncertainty determining compliance with the limits shall be base on the results of the compliance measurement Consequently the measure emissions being less than the maximum allowed emission result in this be a compliant test or passing test The acceptable measuremen
42. t in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 5 SETUP OF EQUIPMENT UNDER TEST 5 1 DESCRIPTION OF SUPPORT UNITS The EUT has been tested as an independent unit together with other necessary accessories or support units The following support units or accessories were used to form a representative test configuration during the tests De eminere Serato recio Won oom N A N A N A N A Unshielded 1 8m N A Multimeter DHA DH 370B N A N A Unshielded 1m 2 Note Grounding was established in accordance with the manufacturer s requirements and conditions for the intended use Page 9 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 5 2 CONFIGURATION OF SYSTEM UNDER TEST AC DC Switching Adapter EUT 2 Multimeter Page 10 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 6 FACILITIES AND ACCREDITATIONS 6 1 FACILITIES All measurement facilities used to collect the measurement data are located at X No 81 1 Lane 210 Pa De 2nd Rd Luchu Hsiang Taoyuan Shien Taiwan x No 11 Wugong 6th Rd Wugu Industrial Park Taipei Hsien 248 Taiwan The sites are con
43. t uncertainty value without requiring revision of the compliance statement is base on conducted and radiated emissions being less than UCISPR which is 3 6dB and 5 2dB respectively CCS values called ULab in CISPR 16 4 2 is less than UCISPR as shown in the table above Therefore MU need not be considered for compliance Page 12 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 7 EMISSION TEST 7 1 CONDUCTED EMISSION MEASUREMENT 7 1 1 LIMITS Class B Frequency dBuV MH e 0 15 0 5 79 66 66 56 56 46 ows ee 5 0 30 0 73 60 60 50 Note 1 The lower limit shall apply at the transition frequencies 2 The limit decreases in line with the logarithm of the frequency in the range 0 15 to 0 50 MHz 3 All emanations from a class A B digital device or system including any network of conductors and apparatus connected thereto shall not exceed the level of field strengths specified above 7 1 2 TEST INSTRUMENTS Conducted Emission Room Name of Equipment Manufacturer Model Serial Number Calibration Due EMI Test Receiver 9kHz 30MHz Rohde amp Schwarz ESHS30 828144 003 11 18 2010 Two Line V Network 9kHz 30MHz Schaffner 03 10013 06 11 2010 LISN 10kHz 100MHz EMCO 3825 2 9106 1809 04 09 2010 ISN 9kHz 30MHz FCC TLISN T4 09 14 2010 Test S W LABVIEW V 6 1 Note The c
44. tance Coil Rectangular type 1mx1m 8 8 2 TEST INSTRUMENT Name of Equipment Manufacturer Modei Seal Number Calibration Due Digital Multimeter CM 312A ET93C 06 208 01 05 30 2010 EMF Testar TES 1390 020401598 05 15 2010 Electromagnetic Field Note 1 The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML ROC and NIST USA 2 N C R No Calibration required 8 8 3 TEST PROCEDURE please refer to measurement standard or CCS SOP PA 027 a The equipment was configured and connected to satisfy its functional requirements It shall be placed on the GRP with the interposition of a 0 1m thick insulating support b The equipment cabinets shall be connected to the safety earth directly on the GRP via the earth terminal of the EUT c The power supply input and output circuits shall be connected to the sources of power supply control and signal d The cables supplied or recommended by the equipment manufacturer shall be used 1 meter of all cables used shall be exposed to the magnetic field Page 55 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 8 4 TEST SETUP Induction Coil 1 2 Dimension of EUT Generator To Earth Ground e For the actual test configuration please refer to the related item Photographs
45. test modes During the above scans the emissions were maximized by cable manipulation The test mode s described in Item 3 1 were scanned during the preliminary test After the preliminary scan we found the test mode described in Item 3 1 producing the highest emission level The worst configuration of EUT and cable of the above highest emission level were recorded for reference of the final test Procedure of Final Test EUT and support equipment were set up on the test bench as per the configuration with highest emission level in the preliminary test A scan was taken on both power lines Line 1 and Line 2 recording at least the six highest emissions Emission frequency and amplitude were recorded into a computer in which correction factors were used to calculate the emission level and compare reading to the applicable limit The test data of the worst case condition s was recorded Page 14 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 7 1 4 TEST SETUP Vert reference plane 4 EMI receiver ey O 40cm EUT aa O g 80cm e o LIS Reference ground plane e For the actual test configuration please refer to the related item Photographs of the Test Configuration 7 1
46. thout the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 7 2 4 TEST SETUP x Test Receiver r 30 cm to 80 cm gt 1 Distance to the ground reference plane vertical or horizontal 2 Distance to the ground reference plane is not critical e For the actual test configuration please refer to the related item Photographs of the Test Configuration 7 2 5 DATA SAMPLE Ereduen QuasiPeak Average Correctrion QuasiPeak Average QuasiPeak Average QuasiPeak Average MHz y reading reading factor result result limit limit margin margin dBuV dBuV dB dBuV dBuV dBuV dBuV dB dB 43 95 33 00 53 95 43 00 64 00 20 05 21 00 Pass Frequency MHz Emission frequency in MHz Reading dBuV Uncorrected Analyzer Receiver reading Insertion loss of LISN if it gt 0 5 dB Correction Factor dB ISN Factor Cable loss Result dBuV Raw reading converted to dBuV and CF added Limit dBuV Limit stated in standard Margin dB Result dBuV Limit dBuV 7 2 6 TEST RESULTS No applicable the EUT don t have LAN Port or Modem port Page 20 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 7 3 RADIATED EMISSION MEASUREMENT 7 3 1 LIMITS dBuV m Frequency At 10m MHz 30
47. uV dBuV dB dB 1 0 1600 56 61 45 91 0 19 56 80 46 10 65 46 55 46 8 66 9 36 Pass 2 0 2400 49 77 41 77 0 13 49 90 41 90 62 10 52 10 12 20 10 20 Pass 3 0 6300 37 37 28 07 0 03 37 40 28 10 56 00 46 00 18 60 17 90 Pass 4 1 2700 36 97 26 77 0 03 37 00 26 80 56 00 46 00 19 00 19 20 Pass 5 3 3350 39 98 27 58 0 12 40 10 27 70 56 00 46 00 15 90 18 30 Pass 6 4 4700 32 40 20 20 0 20 32 60 20 40 56 00 46 00 23 40 25 60 Pass REMARKS L2 Line Two Neutral Line Page 17 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 7 2 CONDUCTED EMISSION MEASUREMENT AT TELECOMMUNICATION PORTS 7 2 1 LIMITS For Class A Equipment Voltage Limit Current Limit Bird dBuV dBuA ME 0 15 0 5 97 87 84 74 53 43 40 30 NOTE The limits decrease linearly with the logarithm of the frequency in the range 0 15 MHz to 0 5 MHz For Class B Equipment Voltage Limit Current Limit I dBuV dBuA MEZ Quasi peak Average Quasi peak Average 0 15 0 5 84 74 74 64 40 30 30 20 Note The limits decrease linearly with the logarithm of the frequency in the range 0 15 MHz to 0 5 MHz 7 2 2 TEST INSTRUMENTS Conducted Emission Room Name of Equipment Manufacturer Model e Serial Number Calibration Due EMI Test Receiver Rohde amp 9kH7 30MHz ESHS30 828144 003 11 18 2010 Two Line V Net
48. work 9kHz 30MHz Schaffner 03 10013 06 11 2010 LISN 10kHz 100MHz EMCO 3825 2 9106 1809 04 09 2010 ISN 9kHz 30MHz FCC TLISN T4 09 14 2010 Test S W LABVIEW V 6 1 NOTE The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML ROC and NIST USA Page 18 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 7 2 3 TEST PROCEDURE please refer to measurement standard or CCS SOP PA 031 Selecting ISN for unscreened cable or a current probe for screened cable to take measurement The port of the EUT was connected to the remote side support equipment through the ISN Current Probe and communication in normal condition Making a overall range scan by using the test receiver controlled by controller and record at least six highest emissions for showing in the test report Emission frequency and amplitude were recorded into a computer in which correction factors were used to calculate the emission level and compare reading to the applicable limit In case of measuring on the screened cable the current limit shall be applied otherwise the voltage limit should be applied The following test mode was scanned during the preliminary test No applicable the EUT don t have LAN Port or Modem port Page 19 This report shall not be reproduced except in full wi
49. x limit classified 1 6 for equipment which is switched manually or switched automatically more frequently than twice per day 2 796 for equipment which is attended whilst use or switched on automatically no more than twice per day Page 31 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E Measurement Date 2009 8 22 AM 09 18 40 V4 16 File AC DC Switching Adapter CP1220 Eddy Chung Remarks Temp 25 C Humidity 55 RH Urms 229 9V Freq 49 961 Range 50A Irms 0 011A Ipk 0 004A cf 4 091 P 1 276W S 2470VA pf 0 517 Test Time 1x10min 10min 100 LIN Line Impedance Network L 0 24ohm j0 150hm N 0 160hm j0 100hm Limits Plt 0 65 Pst 1 00 dmax 4 00 dc 3 30 dtLim 3 30 dt gt Lim 500ms Test completed Result PASSED Plt 0 289 Pst P50s P10s P3s Pis PO 1s Fli dmax dc dt gt Lim ms 1 0 281 0 010 0 010 0 010 0 010 2 363 0 000 1 600 0 110 0 000 Page 32 This report shall not be reproduced except in full without the written approval of Compliance Certification Services Compliance Certification Services Inc Report No 80820002 E 8 IMMUNITY TEST 8 1 GENERAL DESCRIPTION EN 55024 1998 A1 2001 A2 2003 ec e104 bi are Discharge ESD IEC 61000 4 2 8kV air discharge 4kV Contact discharge Performance Criterion B Radi
Download Pdf Manuals
Related Search
Related Contents
PC HP Pro 3515 Microtorre MANUAL DEL USUARIO DESTORNILLADOR DE 2,4 CurrencyXchanger User Guide Samsung 21” CL21A550ML Modelos 2009 Slim Fit TV Manual de Usuario DSS ADMINISTRATIVE LETTER - NC DHHS Online Publications RipEX-HS - Radata Systems 製品概要 - 医療機器開発支援ネットワーク ポータルサイト User's manual - Université Sorbonne Nouvelle Intel Edison Compute Module (IoT) Copyright © All rights reserved.