Home
Operation Manual cub II
Contents
1. conditions When used properly it can withstand 300 cycles amp The new battery can provided 50 hours work after fully charged The charge time normally is 15 hours if the battery is discharged fully The charge time will be shorter if the battery is not discharge fully lt is commended to charge the battery every day Don Not short the positive pole and negative pole when replace the battery Charge the battery at least every 3 months to keep battery in good condition The work hours of the battery is shorter than normally if the battery is not used for a long time e g more than 2 months At this time please cycle battery at least 3 times by charging it and using it until fully discharged to make the battery recover to normal condition Put back the rubber plug after charge is finished to protect the power connector The battery is not warranted due to its service time is greatly influenced by individual The work hour will become shorter many months later It is not a problem of the battery it is the feature of the rechargeable battery ces ee Operating Instructions 2 CUB Il Operating Instructions Introduction The Cub Il scale is a compact scale with many features All our equipment is assembled tested and packed with great care should you find any item incorrect please contact the supplier immediately The Cub ll scale is a high precision weighing instrument which has to be approved and stamped
2. by Weights and Measures This scale is stamped in our production plant or by your local Weights amp Measures office Please check the official stamping stickers are on the scale before use Please read this instruction manual carefully Properly used and maintained this scale will provide years of accurate weighing Please handle it as you would any piece of fine electronic equipment Metrological instructions Important note Contents on legal for trade scales in EEC countries Factory verified scales carry this identification on the label applied on the package Scales identified by the green M label applied on the identification plate can be operated immediately Power up sequence and Turn Off the Scale Bookmark not defined Scales calibrated in two stages carry the corresponding identification on the label applied on the package Straight weighing Re zero function These scales have already been verified in the first Tare Function step declaration of conformity according to EN 45501 8 2 and should receive the second step at their working place This second step must be performed by the certified METTLER TOLEDO after sales service Setting mode Key Function Set over and under vaulue Operation Please contact your local METTLER TOLEDO agency Access to setting mode Function of the key Retail scales used for legal trade must be submitted Parameter list for calibration and verification Pea So mode nr
3. current metrological directives in your Rechargeable jeda acid baffary This is only for some European Countries Ha ee De OT Operating Instructions Installation Precautions This chapter gives detailed instructions and important information to install the Cub Il scale successfully Environment Before you install the scale identify the best location for the equipment The proper environment enhances its operation and longevity Keep in mind the following factors which might have a negative influence on the scale s operation Vibration Vibration diminishes the scale s ability to measure accurately Electrical machinery such as conveyors and drill presses can cause inaccurate and non repeatable readings The scale may also read inaccurately if it is not leveled properly Air current Moving air can cause the scale to read an additional force add weight and have the same effect as vibration Friction A scale cannot measure accurately if an object is rubbing or pressing against the plate Unpacking and inspection Please inspectthe package asit is delivered by the carrier Ifthe shipping container is damaged checkfor internal damage and file a freight claim with the carrier if necessary If the container is undamaged open the box remove the scale and place it on a solid flat surface Please keep the packing material and shipping insert in case you need to return the scale to METTLER TOLEDO The Cub Il is a precision in
4. Cub Il Operation manual Operating Instructions 2230 gt i 180 230 310 READ this manual BEFORE operating or servicing this equipment FOLLOW these instructions carefully SAVE this manual for future reference Daily Maintenance DO NOT allow untrained personnel to operate clean inspect maintain service or tamper with this equipment DO NOT attempt to remove the cover or perform service or maintenance on the internal parts of the scale ALWAYS DISCONNECT this equipment from the power source before cleaning or performing maintenance KEEP the scale clean Wrong Right DO NOT put the scale in the water but you may use watery cloth to clean the scale DO NOT put the scale upside down or remove the scale by holding the spider as left x DO NOT turn the 2 feet on the back tightly to let the air flowing between inside and outside I of the scale smoothly But please turn these 2 feet tightly until seal the gap between the foot and base to void water to get into the scale if you want to wash down the scale with water PLUG the rubber plug in the hole with power connector DC tightly to protect the power connector as left Hole DC p E E Battery Notice A How to move scale 4 The battery 6V 5Ah rechargeable lead acid battery service life will be affected by the charge and discharge
5. age O P 9VDC 500mA Power consumption LCD version 20mA LED version normally 60mA Charging current 500mA 10 CUB Il Specifications are subject to change without notice Operating Instructions METTL DECLARATION OF CONFORMITY We Wir Nous METTLER TOLEDO CHANGZHOU SCALE amp SYSTEM LTD Noi 111 Changxi Rd Changzhou Jiangsu Nosotros People s Republic of China 213001 Wij Nos declare under our sole responsibility that the product erkl ren in alleiniger Verantwortung dass das Produkt d clarons sous notre seule responsabilit que le produit dichiariamo sotto nostra unica responsabilit che il prodotto declaramos bajo nuestra sola responsabilidad que el producto verklaren er volledig verantwoordelijk voor te zijn dat het produkt declaramos de nossa nica respondabilidade que o producto Model Type Cub II RWXX to which this declaration relates is in conformity with the following standards and normative document s auf das sich diese Erkl rung bezieht mit den folgenden EG Richtlinien und Normen iibereinstimmt auquel se rapporte cette d claration est conforme aux Directives du Conseil europ en et aux normes suivantes a cui si riferisce questa dichiarazione amp conforme alle seguenti Direttiva del Consiglio e norme al cual se refiere esta declaraci n conforme a las siguientes directivas y normas waarop deze verklaring betrekking heeft overeenkomt met de volgende EG richtlijnen en n
6. e critical voltage point e LCD o be lit when weight is less than the under value Notice Some model has back display Please check with dealer if the model you purchase has back display 6 CUB II METTLER TOLEDO GB Operations Straight weighing Place the item to be weighed on the platter Remove the item from the platter display will return to O Re zero function There are two ways to re zero the scale 1 Power up Zero 2 Push button Zero Power up Zero The scale will automatically capture zero when it is turned on The power up zero capture range is 10 of the scale capacity When the scale is turned on with a weight on the platter of more than 10 of the capacity the scale will not capture zero the weight display will show and the scale will not be ready for use After removing the weight the scale will capture zero Pushbutton Zero 09 The ZERO key re zeros the scale over a range of 2 of the scale capacity To use this function the scale must be in the gross weighing mode NET cursor must be off and in a no motion condition When the weight on the platter is more then 2 of the scale capacity the depression of the zero key will not be accepted Tare Function The Tare key subtracts the weight of the wrapping material Place the empty container or wrapping material on the platter e g 50g Press E13 key it show net weight Og meanwhile net weight cursor light Place th
7. e item to be weighed in the container or on the wrapping material and then onto the platter Remove the weighed item as well as the container or wrapping material from the platter the displays will show all the negative net weight of the container e g 50g Press e key to return the scale back to gross weighing mode Power Save and automatically turning off scale Power saving feature is used to save battery power These functions can be enabled or disabled through setting When using the battery and the scale is idle for 2 minutes the weight display will only display one decimal on the right and the battery in use cursor is lit This indicates that the scale is in the power saving cycle When weight is placed on the platter or a key is pressed the scale will wake up automatically If there is still no key operation and weight change 15 minutes after power saving status occurred the scale will be turned off automatically Backlight Press key and hold 209 until to hear 2 continuous beeps to turn on the backlight Using the same way or justturning off the scale turn off backlight When power is battery the backlight can be turned off temporarily as there is no weight change or no key touching for 15 seconds while in this case ifweight changes or any key is pressed backlight will be turned on automatically This function is only available in LCD with backlight version CUB Il 7 Operating Instructions Over Under Setting mode P
8. nnect the output end of the adapter to the power connector to initiate charging no matter the scale is turned on or not 3 put the rubber plug back to seal the hole to avoid erosion of the power connector when the scale is in the wet environment Note please charge battery in the dry environment There are two battery cursors one is 3 and the other is 2 to indication the battery situation Please referto section Cursor for detail If the unit is plugged into the wall outlet when battery power is used the power source will automatically switch to the wall transformer And when the AC power is off power source will automatically switch to battery Error Messages The scale will display an error message if a scale problem or incorrect keyboard entry is sensed The error codes are E 11 RAM error E 16 ROM error METTLER TOLEDO Service E 18 EEPROM error E 48 Alarm setup error ERROR software running error Unsteadily or can t find zero nnnnn in weight window Weight is more than full capacity plus 9e Remove items from platter uuuuu in weight display can not capture zero Remove temia mar Baer OF calibrate the scale Specification Feature Description Capacity 1 5kg 3kg 6kg 15kg Division 0 5g lg 2g 5g Weight display 6 digits Operating temperature 10 C 40 C Storage temperature 25 C 50 C Plug in adapter I P local AC volt
9. ormen qual faz refer ncia a presente Declarac o responde s directivas do Conselho Europeu e ds seguintes normas EC marking EC Directive Applicable Standards C 73 23 EEC EN61010 1 Low Voltage ENG 1326 1 1997 A1 98 CLASS B ni EN61326 1 1997 A1 98 Minimal C requirements 90 384 EEC dn Non automatic Weighing M Instruments EN45501 1 0103 1 T6356 EC Type approval certificate Changzhou May 2003 METTLER TOLEDO CHANGZHOU SCALE amp SYSTEM LTD David Zheng Chu Jinlan President Quality Assurance Manager 12 CUB Il Operating Instructions Mettler Toledo Printed in China 01 2004 14 CUB Il
10. ress E key to access to setting mode The display will show default 0 000 the digits on the both sides of decimal point vary with the capacity and its resolution E g 0 000 3kg scale or exiting value Notice All value will be zero after resolution or weight unit is changes Cursor over will light when setting over values and the under will light when setting under value Key Function In over and under setting mode the functions of the keys will be as follows key Description gt 0 lt End setting mode and return the scale to weighing mode S19 Chose value in a circle from 0 to 9 F Chose digit in a circle from left to right Confirm the choice and step forward to next step in a circle of over and under value Set over and under value In setting mode if the cursor over is lit the over value can be set Press key E some times to chose digit you want the chosen digit will blink then press key E13 to change to value of this digit to what you want use the same way to set all digits and get the right over value finally press to confirm the over value and step forwards to under value setting The way to set under value is same as over value When setting is finish press gt scale to the weighing mode For example 3kg scale the over value is 505g under value is 500g key to return the The procedures display show Lit cursor 1 Press p 1o access to set
11. s follows e Light all segments of the display characters This verifies operation of all segments e Display the software part number revision number GEO value and battery type one by one e Capture zero and be ready for normal operation Note Before switching on the Cub Il scale always make sure there is nothing on the platter Press the power key CD until OFF is shown to turn off the scale Spider Insert for shipping protection 3 total 4 CUB Il Operating Instructions Operating Instructions Display and keyboard Operator display METTLER TOLEDO Weight UNDEROVER Max 3 kg Min 20 g e 1 g o return the scale to gross zero if drifting occurs o enter over under setting mode o be lit when power is battery it blinks to indicate the voltage of battery is lower than the required be lit when power is AC or battery is fully charged inking means the voltage is being charged o be lit when left capacity is 2 3 of the full capacity linking means the voltage is being charged o be lit when left capacity is 1 3 of the full capacity linking means the voltage is being charged charging mode blinking means the voltage is being charged In discharging mode To be lit when voltage is almost used up Begin blinking when the power i ofthe battery is less than the requirement The scale will be turned off automatically when voltage j s less than th
12. strument and may be permanently damaged if not shipped in factory approved packaging Package contents for all Cub Il units include Screw for shipping rotection 3 total Cub Il scale platter AC DC power adapter operation manual Setup Open the box and pull up the scale Remove the packing material from each side of the scale Set the unit on a sturdy Remove 3 shipping protection screws on the spider then remove the 3 plastic column inserts under the spider O Level the scale by turning the adjustable feet lt is leveled correctly when the bubble indicator is in the centre of the circle Bubble indicator Good e Wrong All four feet must touch the surface to make sure that Cub II does not rock Then Put the platter on top of Cub Il If no battery is in the scale unpack the power adapter and plug it into the bottom of the scale Plug the line cord into a properly grounded AC power outlet Notice Don t turn the 2 feet on the back tightly to let the air flowing between inside and outside of the scale smoothly But please turn these 2 feet tightly until seal the gap between the foot and base to void water to get into the scale if you want to wash down the scale with water Power up sequence and Turn off the Scale Press the power key CD to turn on the Cub II It goes through a series of self tests when it is turned on The scale performs diagnoses on its ROM and RAM and proceeds to normal operating mode The sequence is a
13. this function 0 no beep i 1 Beepwhen weight is between over and under value Beep range _ 1 normal 2 strong 3 very strong Filter strength Weight unit normal 1 dimmer than 0 2 dimmer than 1 3 dimmer than 2 Off rapidly update Display WP8 on welch hold b is not available on the scales to Europe LED brightness Exit setting mode Press finish key 03 to finish setting SAVE is display to save all changes Press E13 to toggle between SAVE save changes and Abort abort all changes Press to return the scale to weighing mode CUB Il Operating Instructions Appendix Replace battery 1 Put the scale on the side as left 2 Open the holder of the battery by screw driver to unscrew the screws on the battery holder cover on back of the scale 3 Remove the fixing plate by screw diver 4 Disconnect the wire from the battery power poles and remove the battery 5 Connect wire with power poles of new battery Notice that red wire with positive pole black wire with negative pole 6 Putthe fixing board back 7 Putthe cover back with more care about the sealing ring be sure the ring is in the free mode and right place to assure d good sealing result Charge the Rechargeable lead acid battery The scale can charge the lead acid battery 6V 5Ah as follow 1 remove the rubber plug which is to seal the hole where the power connector is 2 co
14. ting mode 0 000 Over 2 Press E then press 19 5 times 0 500 over 3 Press E twice then press er 5 times 0 500 Over 4 Press to set under value 0 000 under 5 Press E then press T9 4 times 0 000 under 6 Press to set over value 0 505 over 7 Press 09 10 back to weighing mode 0 000 The digit in grey shadow mean this digit is blinking Operation When over and under value exists beep will be available as a sound indication and the possible mode will be as follows Weight S3 is O S3 is 1 S3 is 2 Lit cursor gt over value No beep No beep beep over lt under value No beep No beep beep Under lt over value and gt under value No beep beep No beep Over and under Over value under value 0 No beep No beep No beep When both over and under values are O over and under indication function is disabled 8 CUB Il METTLER TOLEDO GB Several parameters in the scale can be changed to enable you to set up the scale to your individual needs Access to setting mode Press and hold 209 until S1 OFF is displayed when turn on the scale Function of the key Key Name Function 209 Finish key Finish setting S19 Toggle key Chose parameter F Back key Step backwards to last step Accept key Confirm choice and step forwards to next step Available parameter On Enable this function Sleeping function ff disable