1. For the Bank mode or Cash dispenser function the hard disk must at least have 2 data partitions 03 2009 System requirements 4 2 SISTORE RemoteView client 8 Siemens Building Technologies Fire Safety amp Security Products Operating system Windows XP SP2 or higher or Windows Vista Pentium IV 2 6 GHz or higher max 16 cameras Pentium IV 3 0 GHz or higher up to 36 cameras Min 1 GB RAM max 2 GB RAM with Windows XP Min 1 GB RAM max 4 GB with Windows Vista S VGA graphics card 1024 x 768 or 1280 x 1024 16 bit colour depth graphics memory 64 MB or higher The graphics card driver must fully support Direct X functionality V9 0C or higher CD ROM drive MF2 keyboard mouse Network connection Min 2 USB ports 2 0 Internet Explorer 6 x or higher Monitor with min 17 inch screen Display resolution 1024 x 768 or higher Optional Laser printer or inkjet printer Optional CD DVD burner 03 2009 Software description 5 Software description SISTORE MX NVS consists of a scalable client server architecture The SISTORE MX NVS servers and the SISTORE RemoteView clients are distributed in the network and enable the design and configuration of small to large video monitoring systems 51 SISTORE MX NVS server Each server supports the administration recording and playback of up to 64 LAN cameras For larger systems multi server configurations are supported It is possible to connect LAN ca
2. 1 Start either SISTORE_MX_NVS_280 exe or SISTORE MX amp RemoteView 280 exe 2 Answer Next and or Finish in the subsequent dialogs 3 Confirm that you want to delete the old version 2 The new version will now be installed 4 If necessary delete the old CEVIS or SIEMENS directory manually 5 Select Start gt Programme gt SISTORE MX NVS or Start gt Programs gt SISTORE RemoteView to start the desired program 6 5 2 From version 2 6x and higher to version 2 80 1 Start either SISTORE MX NVS 29380 exe or SISTORE MX amp RemoteView 280 exe 2 Answer Next and or Finish in the subsequent dialogs 2 he new version is now installed 22 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Configuration T Configuration 7 41 Starting the software 1 Double click on the desktop shortcut SISTORE MX NVS SISTORE Mx MYS OR Select the directory SISTORE MX NVS in the Windows start menu 7 2 Login 1 Choose Login from the File menu 2 Click on the Login button in the toolbar 2 The following dialog box will appear 3a SISTORE MX login User name Administrator Password TITiTitititt ib cs 0K 3 Enter the following in the login dialog User name Enter the user name created for you by the administrator The entry is case sensitive Default in the delivery configuration user name Administrator Password Enter the password cr
3. TERLIAILA LA Turis i ey Ji p You can connect up to 16 modules of this type Each module has 16 optocoupler inputs and 16 relay outputs It is not possible to combine USBOPTOS or USBREL8 with USBOPTOREL16 modules 47 03 2009 USB input output modules 11 1 Technical data of the USB input output modules 11 1 1 Technical data of the USB input module System bus Module address can be set between 0 3 using jumpers up to 4 modules of the same type can be connected simultaneously Inputs 8 optically isolated 5 30 V Input current max 10 mA LEDs initialization status of input signals Connections pluggable screw terminals CE yes Operating temperature 0 to 70 C Power supply via USB 11 1 2 Technical data of the USB output module System bus Module address can be set between 0 3 using jumpers up to 4 modules of the same type can be connected simultaneously Outputs 8 DIL relays max 15 W 1 A Switchable voltage 30 V LEDs initialization status of relays Connections pluggable screw terminals CE yes Operating temperature 0 to 70 C Relay switching time 1 ms incl bounce 11 2 Connecting USB input output modules The modules can either be installed in a cabinet or as desk top units on a PC 11 2 1 Connecting USB input module USBOPT08 1 Connect the module via a plug type terminal strip 2 Assign the module address
4. USB input output modules ooociloooooooooooco O O E L C UL 3 Fig 25 USB output module 1 Relay outputs 2 Output status LED 3 Module addressing 4 Configuration status LED 5 USB port i The cables can be connected in any way as the outputs are no voltage connections ZA max 30V USB Output Module Fig 26 Connection of USB output module 11 2 3 Connecting USB input and output module USBOPTOREL16 1 Connect the module via a plug type terminal strip 2 Assign the module address See Section 11 3 Module addressing 3 Connect the module to the USB interface 2 The operating system detects the USB modules and automatically activates the drivers i In case a message is displayed click OK until all dialog boxes are closed gt The new hardware will be displayed as a Quicklnfo gt Each input output is assigned an LED indicating the current status 50 Siemens Building Technologies Fire Safety amp Security Products 03 2009 USB input output modules 1 2 34 5 yi OO a OOo Oo fH L1 OF OHO OH oO Oo Oo OOO Ooo oo LJ LJ LJ o oco 9 8 7 6 Fig 2 7 USB input and output module 2 Relay optocoupler outputs OV 12V JP1 power supply USB external USB port DIP 1 Optocoupler input Connect the input cables as printed on the input output module The output cables can be connected in any way
5. Mark the checkbox Bank mode Terminate the SISTORE MX NVS software and restart it Switch to configuration mode and mark the checkbox Cash dispenser ene oS Sf Configure cash dispenser mode Further information on this can be found in the SISTORE MX NVS Configuration Manual 9 Restart the PC gt The SISTORE MX NVS software will be restarted automatically or using the start icon on the PC desktop The GAA handler module is also started during this process see task bar 03 2009 USB input output modules 11 USB input output modules i i Siemens Building Technologies Fire Safety amp Security Products USB input output modules are available as accessories See Section 3 Details for ordering An additional power supply is not required The modules are supplied over a USB interface USB input output modules e USBOPTOS input module e USBREL8 output module e USBOPTOREL16 input and output module USBOPT08 USBREL8 Se allel uH se Lar GS a ie reget Dad ERE a Ld et Dae Uu SoD DEED oY ER te i i EE z E a You can connect up to four modules of the same type See Section 11 2 Connecting USB input output modules Each module has eight inputs or outputs With four modules a max number of 32 inputs outputs can be achieved When using more than two modules we recommend connecting a USB splitter hub between the PC and the modules USBOPTOREL16
6. Driver For CEA4870 or EA AST i Hardware drivers go CKA4810 CKA4B20 232 00 KB of space required on the C drive b695404 00 KB af space available on the C drive InstallShield Back Cancel Hardware driver Function CKA4810 CKA4820 Activation of a CKA control panel Hardware watchdog Activation of an additional module in the PC type PWDOG1 from Quancom USB IO Activation of inputs and outputs via USB modules WIBU dongle Licence dongle for 4 9 16 32 or 64 LAN cameras 5 Select CKA4810 CKA4820 or Hardware Watchdog 6 Click Next gt The following dialog box opens InstallShield Wizard Complete The InstallShield Wizard has successfully installed SISTORE M HYS Before you can use the program you must restart Your computer f Yes want to restart my computer now C No will restart my computer later Remove any disks from their dives and then click Finish to complete setup Back Cancel T Click Finish 16 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Installation gt The computer will be restarted gt When the computer is restarted the symbol for CKA will appear in the task bar karza 1 1 CkAsymboi 8 Restart SISTORE MX NVS RemoteView 6 3 Installing RemoteView on a client PC Prerequisite The user must be logged in to Windows at least as a main user or rather as an admin user This applies to th
7. Press the Finish button to exit Setup program Contour Design Irc O AANNMNAMBhBo 11 Mark the checkbox Open the Contour Control Panel 12 Click Finish 2 The software has been installed gt The Contour Shuttle Device Configuration dialog box opens see Fig 14 37 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Setup Configuring the Multimedia Control Panel Contour Shuttle Device Configuration E E x ShuttlePRO v2 About Settings management Device events control User action Button 1 Computer response Do Mathing Target application 9e Global Settings Comment m oem Fig 14 Contour Shuttle Device Configuration dialog box 1 Click Options gt The following context menu opens Create new settings Rename settings Change target application Change target device d Revert to Factory settings Remove seins Export es Export settings info Rebuild the whole settings File 2 Select Import settings 38 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Setup gt The following dialog box opens Import settings Look in Cy SISTORE Mx Qr rl Alarm backup My Recent Burn Documents Download Li Map bel 4 upload Desktop SISTORE Mx pref 1 har oh TNR File name SISTORE MX pref Places Files of type Settings fi
8. LG GSA 2164D R i Suitable data media are all standard CD R CD RW DVD R DVD RW The data medium need not be formatted additionally 29 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Setup 10 Setup Examples of system configurations can be found in the following chapters 10 1 SISTORE MX NVS Server PC LAN CEA 4817020 COM 14 Fig 10 SISTORE MX NVS system overview 2 MX NVS server PC 3 CKA4810 20 optional 10 2 SISTORE MX NVS LAN camera CKA4810 20 LAN LAN e Fig 11 SISTORE MX NVS LAN camera CKA4810 20 system overview 1 CKA4810 20 2 MX NVS server 3 Max 64 LAN cameras Prerequisite e The CKA driver is installed see Section 6 2 Subsequently installing a hardware driver 30 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Setup 1 Connect the CKA4810 4820 control panel COM1A port to the MX NVS server COM1 COM2 2 Configure COM1A on the control panel as an RS232 interface For more information please refer to the respective instruction manual for control panel CKA4810 CKA4820 o OFF uM NE 2 co nen Start the SISTORE MX NVS software Switch to configuration mode Mark the checkbox CCTV keyboard on the System tab Click Apply gt The setting will be saved gt The interface for the control panel is now activated Danay
9. See Section 11 3 Module addressing 3 Connect the module to the USB interface 2 The operating system detects the USB modules and automatically activates the drivers i In case a message is displayed click OK until all dialog boxes are closed gt The new hardware will be displayed as a Quicklnfo 2 Each input is assigned an LED indicating the current status 48 Siemens Building Technologies Fire Safety amp Security Products 03 2009 USB input output modules LE 4 Em NE NE ME ME M M EN _ t 4 S oo 0o ooo Oo oO OGSSI IS Fig 23 USB input module 1 Module addressing Configuration status LED USB port Input status LED Inputs 30V NN Fig 24 Connection of USB input module i Connect the cables as shown in Fig 24 11 2 2 Connecting USB output module USBREL8 1 Connect the module via a plug type terminal strip 2 Assign the module address See Section 11 3 Module addressing 3 Connect the module to the USB interface 2 The operating system detects the USB modules and automatically activates the drivers i In case a message is displayed click OK until all dialog boxes are closed 2 The new hardware will be displayed as a Quicklnfo 2 Each output is assigned an LED indicating the current status 49 Siemens Building Technologies Fire Safety amp Security Products 03 2009
10. as the outputs are no voltage connections The jumper JP1 must connect pin 2 to pin 3 USB 30V NN Fig 28 Connection of USB input module m max 30V USB Output Module Fig 29 Connection of USB output module 51 Siemens Building Technologies Fire Safety amp Security Products 03 2009 USB input output modules 11 3 Module addressing 11 3 1 Modules with 8 inputs outputs Addressing is done using the module address 1 Assign the module addresses using the jumpers See Section 11 2 Connecting USB input output modules Module address O Module address 1 Module address 2 Module address 3 OO O O 11 3 2 Modules with 16 inputs outputs Addressing is done using the module address Assign the module addresses using the DIP switches Module address 11 4 Configuring USB input output modules The configuration of input output modules is described in the SISTORE MX NVS Configuration Manual Section Configuring alarm inputs and Configuring alarm outputs i Digital inputs are not available with the current version of SISTORE MX NVS March 2007 52 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Issued by Siemens Building Technologies Fire amp Security Products GmbH amp Co oHG D 76181 Karlsruhe www buildingtechnologies siemens com Document No A6V10072823 Edition 23 03 2009 2009 Copyright b
11. upgrades enhancements carrectians or modifications provided by COL in any Form Back Cancel Lontour Design Inc 7 Mark the checkbox Yes I agree with all the terms of this license agreement 8 Click Next 35 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Setup gt The following dialog box opens Contour Shuttle setup Destination Folder http www contourdesign com Select the destination folder where you want to install Contour Shuttle To install ko a different location click Browse and select another folder Installation folder C Program Files Contour Shuttle Browse Lontour Design Inc 9 Click Next to install the software in the default directory gt The following dialog box opens Contour Shuttle setup Ready to Install the Program http www contourdesign com TOU are now ready to install Contour Shuttle Press the Next button to begin the installation or the Back button to re enter the installation information Contour Design lac Oo i e i a2 24 2 HAY l Cancel 10 Click Next gt The software will be installed 36 Siemens Building Technologies Fire Safety amp Security Products 03 2009 2 After successful installation the following dialog box opens Contour Shuttle setup Installation Complete http www contourdesign com Contour Shuttle has been successtully installed
12. 09 Software description 10 Siemens Building Technologies Fire Safety amp Security Products Mobotix D12 one or two cameras M1 Models M10 Models M10D Night M12 Models M12D Night M22M Panasonic KX HCM 280 WV NF284 WV NM100 G WV NP1000 WV NP244E WV NP472 WV NS202 WV NS320 WV NW470 WV NW960 Pixord 205 Samsung SNC L200 Siemens CCIC1410 CCIS1337 LP CCIX1345 CFVA IP CVVA IP CFMC1315 LP CCID1410 CCMC1315 LP TELSCAN WEB Server Sony Generic HTTP interface SNC CS11 SNC CS3P SNC DF4OP SNC M1 W SNC M3 W SNC P1 SNC P5 SNC RZ25P SNC RZ30P 2 SNC RZ50P SNC Z20P SNT V704 Toshiba IK WB21A VINWP1 2051 Vivotek MJPEG Models PZ6122 VS2402 IP7138 Depending on the functional scope of the LAN camera many operating elements of the LAN cameras tab may be disabled Altogether a maximum of 64 LAN cameras can be connected Access to LAN cameras takes place with significantly greater latency The reason for this is the greater communication load between the SISTORE MX NVS and a LAN camera Besides the LAN cameras the network also has an effect on the latency The operation of the system can be slow if all connections for LAN cameras 64 are used To keep the processor load below 90 96 we recommend setting the resolution of LAN cameras low CIF format The image quality should be set to approximately 70 96 The following rule applies The higher the perform
13. 4810 CKA4820 SISTORE RemoteView 9 pin Sub D connector GND 5 5 RXD 3 2 TXD 2 3 Interface configuration CKA4810 CKA4820 Protocol SIMATRIX RS232 or SIEMENS IVM e Baud rate 9600 e Parity none 03 2009 Setup 10 4 Multimedia Control Panel SISTORE MX NVS server SISTORE RemoteView client Fig 13 SISTORE MX RemoteView Multimedia Control Panel system overview Ma Multimedia Control Panel Client PC with RemoteView 3 MX NVS server The Multimedia Control Panel ShuttlePRO2 is not a product of Siemens Building Technologies Fire amp Security Products GmbH amp Co oHG It can be ordered from Contour Design Ltd i www contourdesign com product name ShuttlePRO2 Siemens Building Technologies Fire amp Security Products GmbH amp Co oHG can not guarantee fault free operation of the Multimedia Control Panels and does not provide any support In case of problems with the product please contact the manufacturer www contourdesign com Installing the Multimedia control panel 1 Connect the Multimedia Control Panel to a USB port 2 Place the CD in the CD DVD drive 3 Ifthe CD does not automatically start double click the file Autorun exe 33 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Setup 34 Siemens Building Technologies Fire Safety amp Security Products gt The following dialog box opens b Main Menu In x Sh
14. Activity Detection Input Alarm y Active High Trigger Active Low Colour E i Active High switching Active Low Temperature Settings Above normal limit Above high limit Above critical limit Set Fig 18 Alarm configuration 9 Mark the checkbox Activity Detection under Mail if you want to be notified when a motion is detected by a LAN camera 10 Mark the checkbox Input Alarm Trigger under Mail if you want to be notified when an alarm is triggered by a LAN camera 11 Click Save gt The settings have been saved 12 Select the menu sequence Basic configuration gt E mail settings 42 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Setup 2 The E mail configuration dialog opens Send Email at Power Lp Login Failure Activity Detection TRIGGERUSPULSE Gs Input Alarm Trigger TRIGGERUSPULSEms Colour B sew switching Mormal Temperature High Temperature Critical Temperature Mail Settings Mail From SBT FSPeEsiemens cc SMTP IP Address 192 166 0 24 SMTP Username oMTP Password Custom Text SMS Settings Email address of Mobile device Set Fig 19 Email configuration 13 Enter an e mail address for each of the events e g alarm triggered you want to be notified of by e mail in the text fields under Send Email at see Fig 18 and Fig 19 MX NVS application software e g TRIGGER XY PULSE c com Further information on this can be found in the SISTORE MX N
15. Activity Condition of the product Operational startup Has working knowledge Puts the product into The product is not yet personnel of computers operation for the first installed and Training on the product time or changes the configured is recommended existing configuration Has working knowledge Performs the The product is not yet of computers procedures for proper installed and Instruction by technical operation of the configured specialists is necessary Product 1 2 Work safety information Read the general safety precautions before installing the software e Keep this document for reference e Always pass this document on together with the device 1 2 1 Handling Damage due to improper handling e Protect the CD from scratching e Toclean the CD use a soft dry cloth 1 2 2 Transport Damage during transport e Always transport the CD in the case it originally came in 1 2 3 Storage Siemens Building Technologies Fire Safety amp Security Products Damage due to improper storage Protect the CD from moisture Protect the CD from direct sunlight Always store the CD in its protective case Do not keep the CD close to sources of magnetic radiation Keep the CD in an environment with a relative humidity of 10 90 96 Keep the CD between 5 and 55 C Do not store the CD in excessively dusty places 03 2009 Package contents 1 2 4 Service and maintenance Data loss after update Make sure to backup
16. Connections Signal MX NVS Server CKA4810 CKA4820 SISTORE RemoteView 9 pin Sub D connector GND 5 5 RXD 3 2 TXD 2 3 Interface configuration CKA4810 CKA4820 Protocol SIMATRIX RS232 or SIEMENS IVM e Baud rate 9600 e Parity none 10 3 SISTORE MX NVS server SISTORE RemoteView client CKA4810 20 Siemens Building Technologies Fire Safety amp Security Products SISTORE MX NVS SISTORE RemoteView CKA4820 system overview Fig 12 1 CKA4810 20 2 Client PC with RemoteView 3 MX NVS server 4 Max 64 LAN cameras Prerequisite e The CKA driver is installed see Section 6 2 Subsequently installing a hardware driver 31 03 2009 Setup 32 Siemens Building Technologies Fire Safety amp Security Products 1 Connect the CKA4810 CKA4820 control panel COM1A port to the client PC COM1 COM2 Configure COM1A on the control panel as an RS232 interface For more information please refer to the respective instruction manual for control panel CKA4810 CKA4820 OFF n J o ge gm amp r Mp gt The setting will be saved gt The interface for the control panel is now activated Connections puce r E M a Start the SISTORE MX NVS RemoteView software owitch to RemoteView configuration mode Mark the checkbox CCTV keyboard on the System tab Click Apply Signal Client PC CKA
17. Network trigger data for Siemens CCIX1345 LAN camera 4 Enter the IP HTTP TCP port and the IP SMTP port of the LAN camera in the LAN trigger group field Siemens Building Technologies Fire Safety amp Security Products 03 2009 Setup 10 5 2 Configuring a LAN camera 1 Open the Internet Explorer 2 Enter the IP address of the Siemens LAN camera in the Address field of the Internet Explorer The IP address of the device can be changed subsequently Please refer to the user manual for the i The default IP address of the Siemens LAN camera can be found on a label on the top of the device camera 3 Press the Enter key 4 Answer Yes in the Security alert which opens gt The following dialog box opens Login Loin Fig 16 Camera login dialog 5 Enter admin in the User Name field 6 Enter admin in the Password field T Click Login gt The device homepage will be opened Ehe Dd m Cute Comb Help Id Quar C xp E fe Oen rnm en E D a dur a rares E E rd az glm EET Fig 17 Device homepage a4 Language selection box Main menus 3 Live image display area 4 Streaming information 41 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Setup 8 Select the menu sequence Basic configuration gt Configure alarm 2 The alarm configuration dialog opens Configure Alarm Output Mail SMS ET Trigger Level Power Lp Login Failure
18. OK 24 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Configuration 7 5 Select language 1 Select the menu sequence Administration gt Configuration gt The Configuration dialog box will appear 2 Select the System tab js SISTORE MX Configuration x x Ma Holidays Cash box fa Map HE User management E Multi monitor E Information m System uH LAN cameras 5 Alam input HA Recording Es Metwark ie E mail and 5M5 FIP hy Alarm connection E Database Recording media 17002 MB 0 MB free 242454 MB 0 MB free 259256 MB 137385 MB free Options Audio signal Extended logbook entries 2 user login Bank mode Cash dispenser View Always in foreground On screen keyboard BS003 MB 61956 MB free 1138435 MB 4553 MB free Application start stap w Auto logout Start with password query v Automatic recording on start Shutdown and exit minute s of allt inactivity Recording status display C Off C Symbol Test and symbol System name SISTORE Mes Recording Memory 25 zi kByframe Enable software trigger I Encrypt video files Warnings Send email SendSWS P Slam call Display Mode Switch camera on video monitor every E second s Use max hard disk storage capacity Show event on videa monitor Far at least 0 second s Switch ca
19. SIEMENS SISTORE MX NVS Application Software For Network Based Video Recording Installation Manual V2 80 Building Technologies Fire Safety amp Security Products Lieferm glichkeiten und technische Anderungen vorbehalten Data and design subject to change without notice Supply subject to availability 2009 Copyright by Siemens Building Technologies Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor Der Empfanger anerkennt diese Rechte und wird dieses Dokument nicht ohne unsere vorgangige schriftliche Erm chtigung ganz oder teilweise Dritten zug nglich machen oder au erhalb des Zweckes verwenden zu dem es ihm bergeben worden ist We reserve all rights in this document and in the subject thereof By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part nor to make them available to any third party without our prior express written authorization nor to use it for any purpose other than for which it was delivered to him About this document This document contains information on the installation configuration and setup of SISTORE MX NVS For more detailed information on configuration please refer to the Configuration Manual For information on operation please refer to the User Manual Trademarks SISTORE is a tradem
20. System User Accounts Windows Wireless Link Wireless Cameras Tasks Center Audio Devices Firewall Network Set set the date time and time zone for your computer Date and Time Properties 5 3 x Date amp Time Time Zone 7 8 9 10 ll 14 15 17 18 21 22 23 24 25 25 17 33 24 Current time zone Ww Europe Standard Time ENETN Fig 8 Open Date Time dialog box from the Start menu 27 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Configuration 7 8 Get time of Client PC from an NTP Server An NTP Server always provides the current time The time of your PC will be updated continuously with the time from the NTP Server This is a periodic synchronization mode i e the time is updated at regular intervals In order to get the time from an NTP Server the IP address of the NTP Server must be specified 1 Open the command prompt of your PC via the Windows Start menu 2 Enter the following command net time setsntp xxx xx xx xxX 3 Enter the IP address of the NTP Server for xxx Xx Xx Xxx Microsoft Windows 2666 Version 5 00 2195 CC Copyright 1985 2000 Microsoft Corp Co NWIMNT S net time setsntpi xxx xxx XMM XXXL Fig 9 Command prompt window 4 Restart your PC or enter the following command in the command prompt of your PC net stop w32time net start w32time The IP address of an appropriate server can be foun
21. VS Configuration Manual XY represents the desired LAN trigger input Enter a figure between 01 and 32 instead of XY d The e mail addresses must contain the text assigned to the alarm input as defined in the SISTORE 14 Enter an e mail address in the Mail From text field 15 Enter the IP address of the SISTORE MX in the SMTP IP Address field 16 Click Save gt The settings have been saved 17 Click Log Out on the device homepage gt The alarm connection is now activated 43 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Setup 10 6 SISTORE MX NVS SISTORE RemoteView multi server mode Fig 20 SISTORE MX NVS SISTORE RemoteView system overview Max 64 LAN cameras IP domes per server Max 16 client PCs per server 3 Max 10 MX NVS servers per client 44 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Setup 10 7 SISTORE MX NVS MX Multi Channel Box RCI 0601 and CDM GAA 1 GAA 2 GAA 3 RS232 RS232 RS232 c c RCIO601 c n RCIOG01 MX NVS Bus Adr 1 Adr 2 Adr 3 RS 485 zo C p fe RS232 A gt Ad COM 1 2 Io m Converter 4855D98R Fig 21 MX NVS Multi Channel Box RCI 0601 and CDM system overview A Cable 9 pin plug plug 2 3 3 2 1 Connect the MX Multi Channel Box to the SISTORE MX NVS server PC COM1 COM2 For this you require the converter 485SD9R B amp B Electronics Plug t
22. all data before updating the system 2 Package contents i 3 Details for ordering e CD with SISTORE MX NVS software e SISTORE MX NVS Configuration Manual and User Manual on CD e SISTORE MX NVS Installation Manual e Supplement Getting Started in six languages e USB dongle for software licence with 4 9 16 32 or 64 LAN cameras Dongle 4 Operation of 4 LAN cameras Dongle 9 Operation of 9 LAN cameras Dongle 16 Operation of 16 LAN cameras Dongle 32 Operation of 32 LAN cameras Dongle 64 Operation of 64 LAN cameras If no USB dongle is installed the software only runs in demo mode In demo mode you can configure and evaluate only one LAN camera Type SISTORE MX NVS 4 SISTORE MX NVS 9 SISTORE MX NVS 16 SISTORE MX NVS 32 SISTORE MX NVS 64 Type USBOPTO8 USBREL8 USBOPTOREL16 CKA4820 MX Multi Channel Box CDM i Siemens Building Technologies POS Data 6 Fire Safety amp Security Products Order No S24245 P5099 A1 S24245 P5099 A2 S24245 P5099 A3 S24245 P5099 A4 S24245 P5099 A5 Designation Open IP software for 4 IP cameras Open IP software for 9 IP cameras Open IP software for 16 IP cameras Open IP software for 32 IP cameras Open IP software for 64 IP cameras Accessories not included in delivery Order No 2GF4811 8CH 2GF4811 8CG 2GF4811 8CJ 2GF2400 8EC Designation USB input module 8 channels with optocoupler function USB output module 8 cha
23. ance of the server PC the higher the image quality and the lower the processor load See Section 4 System requirements Exact specifications for the image quality and the required hard drive capacity are not possible with LAN cameras since each LAN camera has different quality levels and interprets specifications differently 03 2009 Installation 6 Installation 6 1 Installing SISTORE MX NVS Prerequisites e he user must be logged in to Windows at least as a main user or rather as an admin user This applies to the first time installation of the software as well as to a subsequent driver update e For the system requirements please refer to Section 4 System requirements 1 Place the CD in the appropriate drive of your PC 2 Start SISTORE MX NVS 2980 exe The installation program will start automatically when the CD is inserted if your operating system has the appropriate configuration Choose Setup Language X Select the language for the installation from ei the choices below OF Cancel 3 Select a language 4 Click OK 11 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Installation gt The following window will appear Welcome to the InstallShield Wizard for SISTORE Hx NYS The Installs hield Wizard will install SISTORE Mx NYS on your computer To continue click Next 5 Click Next gt The following dialog box opens Choose Destina
24. ark of Fire amp Security Products GmbH amp Co oHG Microsoft is a registered trademark and Windows a trademark of Microsoft Corporation All other product or company names mentioned in this document are trademarks or registered trademarks of their respective owners and are used only for purposes of identification or description Contacting us If you have questions or suggestions regarding the product or this documentation please contact our Customer Support Center Intranet http intranet sbt siemens com fs CSC E Mail fs support sbt siemens com Tel 49 89 9221 8000 Training courses oiemens Fire amp Security Products provides training courses for all products Contents Siemens Building Technologies Fire Safety amp Security Products 1 1 1 2 1 2 1 1 2 2 1 2 3 1 2 4 4 1 4 2 5 1 5 2 5 3 6 1 6 2 6 3 6 4 6 5 6 5 1 6 5 2 7 1 7 2 7 3 1 4 1 4 7 1 4 2 1 5 7 6 1 1 7 8 7 9 Lj 5 Eie Nice 5 Work safety llntOrmatiOn asseris a a aada 5 Fan CHINN Chis secures RETI RE UT LU ET 5 TANS DOM becana ee E eee ieee ees 5 1S 2 0 Seen cee eR ee a aaa 5 Service and maintenance aic ensuite oce es ha cad eru tu qa ETE DE ERI NK ETE 6 gi ie Clo ero a i is i em 6 Details for Ordering 24er tdem rg rebua viai o Evan ied ead vau Few aeu eitis dota u ds 6 System requiremedllts ooroisise ei eric red cu abo rive aod eoa
25. d in the Internet or you can contact your system administrator 7 9 Further information For more information on the SISTORE MX NVS V2 80 software and the WebView version please refer to the online help or to the relevant document on the software CD 28 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Software update 8 Software update Should it be necessary to reinstall or repair the SISTORE MX NVS software please proceed as follows 1 Follow the description in Section 6 2 Subsequently installing a hardware driver 2 Select the option Update gt This will have the effect of re installing every files that have been installed during the first installation It should be noted that existing files may be overwritten in this procedure The files containing the configuration settings the user management data and the recorded sequences will not be overwritten 9 Writing to CD DVD Prerequisite e In order to backup data on CD DVD the burner software Nero V6 x must be installed on the NVS PC e A suitable burner is available i The functions Double Layer and or Light Scribe are available only if the following conditions are met e The burner software Nero Version 6 6 4 x or higher or Version 7 x is installed The software has been tested successfully using the following external USB burners combined CD DVD burners Plextor PX 740UF LiteOn SOHW 1673 SX 02
26. d that vau esit all Windows programs before running this Setup program Click Cancel to quit Setup and close any programs you have running Click Nest to continue with the Setup program WARNING This program is protected by copyright law and international treaties Unauthorized reproduction or distribution of this program or any portion of it may result in severe civil and criminal penalties and will be prosecuted to the maximum extent possible under law Lontour Design Inc 6 Click Next gt The following dialog box opens Contour Shuttle setup 2 X License Agreement http www contourdesign com Please closely read the following license agreement Do you accept all the terms of the following license agreement Software Licensing Agreement By installing copying or otherwise using the ShuttlePRU or Shuttlespress Multimedia Controller software you agree ta be bound by the terms of the following license agreement If WOU do nat agree to the terms of this license you should promptly return the product to its place of purchase and destroy all copies you may have made of iE in any Form Grant of License Contour Design Inc COI grants you this non esclistye license to use the Software subject to the restrictions set forth below Definitions The Software means the ShuttlePRE or Shuttles press Multimedia Controller Software itt components or denvative modules and documentation along with any
27. e first time installation of the software as well as to a subsequent update For the system requirements please refer to Section 4 System requirements 1 You can either use a CD drive or copy the software supplied onto a memory stick 2 Launch the file SISTORE MX RemoteView 280 exe The installation program will start automatically when the CD is inserted if your operating system has the appropriate configuration Choose Setup Language X Select the language for the installation from the choices below OF Cancel Fig 1 Setup language 3 Select a language 4 Click OK 17 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Installation gt The following dialog box opens Welcome to the InstallShield Wizard for SISTORE Hx HemoteView The InstallShield Wizard will install SISTORE M Remoteview on your computer To continue click Next 4 Back Cancel Fig 2 InstallShield Wizard 5 Click Next gt The following dialog box opens Choose Destination Location Select folder where setup will install files Setup will install SISTORE Mx Hemoteview in the following folder To install to this folder click Next To install ta a different folder click Browse and select another tolder Destination Folder Co Demens SIS TORE Mes REMOTEVIEW Browse InstallShield Back Cancel Fig 3 Choose Destination Location dialog 6 Do not chang
28. e the destination folder 7 Click Next 18 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Installation gt The following dialog box opens Setup Type Select the setup type that best suits your needs Click the type of setup you prefer 1 Rermoteview installation Description 2 User defined installation This installs only the revision application Installshield Back Cancel Fig 4 Setup type dialog 8 Select the setup type RemoteView 9 Click Next gt The following dialog box opens Select Program Folder Please select a program folder E Setup will add program icons to the Program Folder listed below You may type a new folder name ar select ane from the existing folders list Click Nest to continue Program Folders SISTORE Met REMOT EVIE Existing Folders Administrative Tools DIH TERM Full5 hot 8 SOL International SOL MuliT erm 7 SISTORE Mx HYS Startup InstallShield Back Cancel Fig 5 Select program folder dialog 10 Do not change the SISTORE MX REMOTEVIEW program folder 11 Click Next 19 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Installation gt The following window will appear AN Please close all running programs before vau start the installation 12 Close all programs and click OK gt The installation will now be carried out gt Wait until the window InstallShield Wi
29. eated for you by the administrator The password is displayed as asterisks The entry is case sensitive Default in the delivery configuration password Administrator 4 Confirm with OK i We advice to change the administrator s password The user name Administrator cannot be deleted 23 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Configuration 7 3 Show last users to log on 1 Click on the arrow in the Login button Ay 2 The last five users to log on will be displayed 7 4 Change password There are two options for changing the password By selecting the menu item New password e By selecting the menu item User management 7 4 1 Changing the password using the menu item New password Select New password in the File menu 2 Enter the current password in the appropriate field for the Old password 3 Enter the new password in the fields New password and Confirm password i The password should be at least eight characters long 4 Confirm with OK 7 4 2 Changing the password using the menu item User management Prerequisite e You need the authorisation Configuration 1 Select Configuration from the Administration menu gt The Configuration dialog appears 2 Select the User management tab 3 Enter the new password in the fields Password and Confirm password i The password should be at least 8 characters long 4 Confirm with
30. enu item New password 24 Changing the password using the menu item User management 24 Select language ico tein nut ret os eo apad ne E ERI DECEM L EM DSC TUE 25 Resolution and file format ccccccsecccceeeeceeeeeceeeeseeeeeseeeeeseneeesaeeesaees 26 Set date and time of client PC seseeeeeeeeeeeeeeeeenrneeee 27 Get time of Client PC from an NTP Server eeeeeeeeereeeeeree 28 FUPIGE ATO nno MR Ln 28 Software Update cscs d waco ie Ee eoe e oie aee see eee uode 29 WHITING To CD DVD iis iti rxbcuie pelas kite suia Maura ka Ur Bees werk DERE Eau da V SiS 29 3 03 2009 4 Siemens Building Technologies Fire Safety amp Security Products 10 10 1 10 2 10 3 10 4 10 5 10 5 1 10 5 2 10 6 10 7 10 8 11 11 1 11 1 1 11 1 2 11 2 11 2 1 11 2 2 11 2 3 11 3 11 3 1 11 3 2 11 4 SIS TORE MX NVS Server PO nde oboe at ERE tad teeta 30 SISTORE MX NVS LAN camera CKAA4810 20 30 SISTORE MX NVS server SISTORE RemoteView client CISAdGT0 20 i ort studeo chatted wobec tet uf cor Pata fue die M E 31 Multimedia Control Panel SISTORE MX NVS server SISTORE RemoteView client lsseeeeesseseseeseee nennen nennen nnn 33 Activating alarm connection from Siemens LAN cameras CCIx1345 40 IgtehinddE POMS rronin lalate PD DERI aC han Dn ded 40 Contiguring a LAN Camel ais e anco Reb ic
31. eo files in the Recording section Recording Date compression 25 E kB frame Enable software tigger Encrypt video files Fig 7 Encrypt video files checkbox AVI files can be handled with the Media Player of Windows provided that the operating system provides an appropriate codec The resolution of the images stored in these files is dependent on the operating characteristics of the individual cameras and the settings made The resolution of the transmitted images can be configured individually for each camera 03 2009 Configuration 7 7 Set date and time of client PC Adjust the time of your PC to the time zone where your PC is run e g GMT 01 00 Amsterdam Berlin Bern Rome Stockholm Vienna You can set these parameters in the dialog box that you open via the Start menu Start gt Settings gt Control Panel gt Date and Time E Control Panel File Edit View Favorites Tools Help Back T g pi pO Search Folders rs E x er FE Address EB Control Panel JE 2 2 amp Accessibility Add Hardware Add or Administrative Automatic Data Sources PRISER Display Folder Options Fonts Options Remov Tools Updates ODBC w 9B gt 9 b 2 9 same Internet Keyboard Mouse Network Network Setup Phone and Power Options Printers and Regional and Controllers Options Connections Wizard Modem Faxes Language D o g 5 a Scanners and Scheduled Security Sounds and Speech
32. he RS232 end of the converter onto the COM port of the SISTORE MX NVS server 2 Connect the cash dispensers to the RCIO601 Information on this can be found in the user manual for the MX Multi Channel Box RCI 0601 3 Startthe SISTORE MX NVS software 4 Switch to configuration mode 5 Select the System tab 6 Mark the checkbox Bank mode T Terminate the SISTORE MX NVS software and restart it 8 Switch to configuration mode and mark the checkbox Cash dispenser 9 Configure cash dispenser mode Further information on this can be found in the SISTORE MX NVS Configuration Manual 10 Restart the PC gt The SISTORE MX NVS software will be restarted automatically or using the start icon on the PC desktop The GAA handler module is also started during this process see task bar 45 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Setup 10 8 SISTORE MX NVS Miniter interface and Miniter reader 46 Siemens Building Technologies Fire Safety amp Security Products Miniter reader Miniter interface MX NVS Bus GOMT COM2 MX NVS Senrver PC Fig 22 Miniter interface and Miniter reader system overview Cable 9 pin plug socket 1 1 1 Connect the Miniter interface to the SISTORE MX NVS server PC COM1 COM2 For this you require a 9 pin 1 1 cable with plug and socket Start the SISTORE MX NVS software Switch to configuration mode Select the System tab
33. i nexe mia cuna una uh ies 41 SISTORE MX NVS SISTORE RemoteView multi server mode 44 SISTORE MX NVS MX Multi Channel Box RCI 0601 and CDM 45 SISTORE MX NVS Miniter interface and Miniter reader 46 USB input output modules ecce encre nnne nnn 47 Technical data of the USB input output modules 48 Technical data of the USB input module 48 Technical data of the USB output module 48 Connecting USB input output modules eeeeeeeeeeeeees 48 Connecting USB input module USBOPTO e eeeesssee 48 Connecting USB output module USBRELS eeeuesssus 49 Connecting USB input and output module USBOPTOREL 16 50 Modlle addressllif ier e decibt ataten C oM uscen linus cde die ntt dae pu dot ds 52 Modules with 8 inputs OUtputs ccccccccseececeeeeeceeeeeeeeseesesseeeesseeeees 52 Modules with 16 inputs OUtpUtS cccccccccecceseeeeceeeeeseeeeeseeeeseeeeesaaeeees 52 Configuring USB input output modules eese 52 03 2009 1 Safety Safety 1 1 Target readers The instructions in this document are designed for the following target readers Target readers Qualification
34. le Cancel E Navigate to the directory where SISTORE MX NVS is installed Open the file SISTORE MX pref or SISTORE MX RemoteView pref Click Apply If you also want to use the Multimedia Control Panel with the SISTORE Player repeat steps 1 to 5 and import the file SISTOREPlayer pref 7 Click OK gt The Multimedia Control Panel is ready for operation 3 4 5 6 39 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Setup 10 5 Activating alarm connection from Siemens LAN cameras CCIx1345 Prerequisites e The Siemens LAN camera is installed Please also refer to the installation manual for the camera e The recording mode for the appropriate LAN trigger input has been configured in SISTORE MX NVS e A registry entry for LAN trigger inputs is available Further information on this can be found in the Configuration Manual 10 5 1 Matching IP ports i 40 SISTORE MX NVS supports up to 32 LAN trigger inputs alarm inputs 101 to 132 in the Alarm input tab These inputs can be addressed via the IP HTTP port 13801 and the IP SMTP port 13802 The IP port of the LAN camera and the IP port of the SISTORE MX NVS application software must be identical 1 Start the SISTORE MX NVS application software See Sections 7 1 Starting the software and 7 2 Login Switch to configuration mode Select the Network tab LAM trigger HTTP TLF feo SMTP 25 Fig 15
35. mera group every 5 second s Operating console CoM F comi gt Release of the PT contral ta 1 E minute s inactivity 1000 E mi PTZ timeout Test options Allow alarm simulation Display frame rate Show motions Key delay Help Apply Cancel OF 3 Select the desired language OR Select Automatic and the application starts in the language set as the regional language in the operating system Click OK 5 Restart SISTORE MX NVS gt The language has been changed e To have the Windows dialogs e g Print Save AS displayed in another language you must i additionally change the language of the operating system in the Control Panel To change the date and time format make the desired settings in the Regional Options in the Control Panel 25 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Configuration 7 6 Resolution and file format 26 Siemens Building Technologies Fire Safety amp Security Products The files stored by SISTORE MX NVS have the extension K26 or AVI depending on the system parameterization These settings are made in the Recording section in the System tab of the Configuration dialog Files with the extension K26 are encrypted image files in AVI similar format They can be evaluated only with the SISTORE Player To create these files select the System tab in the Configuration dialog and tick the checkbox Encrypt vid
36. meras from Siemens as well as from third parties to the server See Section 5 3 General information on LAN cameras 5 2 SISTORE RemoteView client SISTORE RemoteView is a client application which can be installed independent of the other software components In this version SISTORE RemoteView SISTORE Player and the Software Codec are installed SISTORE RemoteView is only used for the evaluation of video data 5 3 General information on LAN cameras Siemens Building Technologies Fire Safety amp Security Products Be aware of the following when using LAN cameras e Multiple users can access LAN cameras simultaneously Simultaneous access by multiple users lowers the frame rate e Settings made by a user on a LAN camera such as modifying the image parameters via a browser have system wide effects SISTORE MX NVS supports the following LAN cameras Arecont Vision 1300 Vision 2100 Vision 3100 Vision 3130 Day Vision 3130 Night Axis 205 206 W 206M 207MW 209FD 210 211 211M 212 PTZ 213 PTZ 215 PTZ 216FD 216MFD 221 223M 225FD 231D 232D 233D 240Q 241Q 2418 Generic HTTP Interface V1 0 VAPIX Interface CBC MP2A MP3DN Day MP3DN Night Convision VISTABOX 6XX Dallmeier DF3000 IP Digilan TV7214 Eneo ENC 1003L IQ invision 1Q501 10510 1Q511 IQ603 IQ 752 10753 1Q755 JVC VN C10U VN C30U VN C625U VN C655U Lumenera LE175C LE275C LE375C 03 20
37. ni ewe ves aa alo rin Ere rug eu ERO Ea 7 SISTORE MX NVS server eeesseeeeseeeee nenne nnne nnne nnn nnns 7 SISTORE RemoteView client cccccssseeeceesseeceeeeeeceeseeessenseesseaeeenes 8 Software description uico io eoe ede ooo Fe ce oor eee poo oe aei tans o esee v core voce 9 SISTORE MX NVS server eeesseeeeseeeee nne nennen nennen nnn nnns 9 SISTORE RemoteView client cccccssscecceeseeeceeseeeceseeeeeasseesseaeeenes 9 General information on LAN cameras esses 9 NYS CANARIO MD eM ec rem E 11 Installing SIS TORE MX NVS seti udaes ht tiae eeu Es cu qr euo do bride ida 11 Subsequently installing a hardware driver ssssesessss 15 Installing RemoteView on a client PC eeeeseeeeeeeeeeeeee 17 Removing SISTORE MX NVS ssssessseesennenenn mener nnns 21 Updating SISTORE MX NVS and RemoteView software 22 From version 2 5x to version 2 80 sseesseesssesseseeneeen nenne 22 From version 2 6x and higher to version 2 80 seeesseuss 22 COTO Ul ATO e M 23 Starting the software cc cccccccssececceeseeeceessecseuseeeseaeeecsegeeesseaseeessaeeess 23 Boe a E E 23 Show last users to OG ON i uada dori tivi c pev ceondauaadenetedentaerteacgebns 24 Change password coenae tede coda ete T ed vio c aaa 24 Changing the password using the m
38. nnels with relay function USB input and output modules with 16 optocoupler inputs and 16 relay outputs PTZ control unit with joystick 24245 F5092 A1 For connection of cash dispensers or cash box systems Further accessories can be found in the Internet www buildingtechnologies siemens com gt Products amp Systems gt Electronic Security gt Catalogue Downloads 03 2009 System requirements 4 System requirements 4 41 SISTORE MX NVS server Eu en Siemens Building Technologies Fire Safety amp Security Products e Operating system Windows XP SP2 or higher or Windows Vista e Pentium IV 2 6 GHz or higher max 16 cameras e Pentium IV 3 0 GHz or higher or rather Core 2 Duo Quattro 2 6 GHz or higher up to 64 cameras e Min 1 GB RAM max 2 GB with Windows XP e Min 1 GB RAM max 4 GB with Windows Vista S VGA graphics card 1024 x 768 16 bit colour depth graphics memory 64 MB or higher The graphics card driver must fully support Direct X functionality V9 0C or higher Hard disk capacity 120 GB or higher System partition 10 GB or more CD DVD burner MF2 keyboard mouse Network connection Min 2 USB ports 2 0 Internet Explorer 6 x or higher Monitor with min 17 inch screen Display resolution 1024 x 768 pixel or higher Optional Laser printer or inkjet printer Some AMD processors do not support the tamper detection function The corresponding buttons will be disabled in the software
39. roducts 03 2009 Installation 6 2 Subsequently installing a hardware driver Prerequisites The user must be logged in to Windows at least as a main user or rather as an admin user This applies to the first time installation of the software as well as to a subsequent driver update For the system requirements please refer to Section 4 System requirements 1 Place the CD in the appropriate drive of your PC 2 Start SISTORE MX NVS 2980 exe The installation program will start automatically when the CD is inserted if your operating system has the appropriate configuration gt The following window will appear Welcome Modify repair ar remove the program Welcome ta the SISTORE Mx NYS Setup Maintenance program This program lets wou modify the current installation Click ane of the options below f Modify Select new program components to add or select currently installed components to remove Tg Reinstall all program components installed by the previous setup C Remove a Remove all installed components Installshield Cancel 3 Select the option Modify 4 Click Next 15 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Installation gt The following dialog box opens Select Components h T Select the components setup will install Select the components vau want to install and deselect the components vou do nat want bo install Description
40. tion Location Select folder where setup will install Files Setup will install SISTORE Mi NYS in the Following folder To install ta this folder click Nest Ta install ta a different folder click Browse and select another tolder Destination Folder C Program Filezsoiemens SIS TORE Mx HYS Browse InstallShield Back Cancel 6 Select a destination folder 7 Click Next 12 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Installation gt The following dialog box opens Setup Type Select the setup type that best suits your needs Click the type of setup vau prefer 1 Network cameras Description 2 User defined installation This installs SISTORE ME N Yv5 and drivers for network cameras For use of this software please plug in the delivered USB Dongle Attention if na LISB Dangle i plugged the software starts in the DEMO mode where 1 IP camera Is supported Installs held Back Cancel 8 Select the desired software component see Section 5 Software description More information on user defined installation can be found in Section 6 2 Subsequently installing a hardware driver 9 Click Next gt The following dialog box opens Select Program Folder Please select 4 program folder Setup will add program icons to the Program Folder listed below fou may type a new folder name or select one fram the existing folders list Click Next
41. to continue Program Folders SISTORE Mx NWS Existing Folders Administrative Tools DIN TERM FullS hot 8 SOL International SOL Mult ern 7 Startup InstallShield Back Cancel 10 Enter the name of the program folder and click Next gt The following window will appear 13 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Installation AN Please close all running programs before vou start Ehe installation 11 Close all programs and click OK 2 The desired components will now be installed 12 Click Next gt The following window will appear 4 a Should SETUP create a link to SISTORE MX in the startup Folder 13 Confirm with Yes gt The following dialog box opens InstallShield Wizard Complete The InstallShield Wizard has successfully installed SISTORE Me NYS Before you can use the program you must restart your computer Yes want to restart my computer now C No will restart my computer later Remove any disks from their dives and then click Finish to complete setup Back Cancel 14 Click Finish gt The computer will be restarted 15 After restarting your PC connect a USB dongle to the USB port See Section 2 Package contents 16 Follow the instructions of the InstallShield Wizard until the dongle driver is installed correctly 17 Restart SISTORE MX NVS 14 Siemens Building Technologies Fire Safety amp Security P
42. uttle Devices Windows Drivers INSTALL DRIVER ABOUT SHUTTLE DEVICES BROWSE CD CONTENTS SUPPORT OTHER PRODUCTS EXIT 4 Click on INSTALL DRIVER gt The following dialog box opens b Install Driver nm x Shuttle Devices IMPORTANT NOTES BEFORE INSTALLING THE DRIVER 98 98 beg pebas am Note Connect your Shuttle device to any available USB part and allow Windows to install its default driver Windows 88 users Windows 88 displays the Add Mew Hardware Wizard which asks you where to lock for drivers Accept the standard search without cptians no floppy drive CD ROM of user specified location In some cases you may be prompted to insert the Windows 88 CD ROM for necessary system files After Windows installs the default USB driver launch Setup Mates for Windows 2000 and XP users a Installing the driver requires system adminstrator security privileges b The Shuttle device driver is nat digitally signed by Microsoft A warning message may appear during the installation Click OK to proceed with the installation CAN AAT H MAIN MENU e F H I ral 5 Click LAUNCH SETUP 03 2009 gt The following dialog box opens Contour Shuttle setup 3 Ea Welcome to the Installation Wizard ONTO AT http www contourdesign com Welcome to the Contour Shuttle Setup program This program will install Contour Shuttle an your computer kis strongly recommende
43. y Siemens Building Technologies Data and design subject to change without notice Supply subject to availability Printed in the Federal Republic of Germany on environment friendly chlorine free paper
44. zard Complete appears InstallShield Wizard Complete Setup has finished installing SISTORE Mx Remateview an Your computer Back Cancel Fig 6 InstallShield Wizard Complete dialog 13 Click Finish 3 SISTORE RemoteView has been installed 20 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Installation 6 4 Removing SISTORE MX NVS 1 Start SISTORE_MX_NVS_280 exe gt The following window will appear Welcome Modify repair ar remove the program Welcome to the SISTORE MX NYS Setup Maintenance program This program lets you modify the current installation Click one of the options below C Modify Select new program components to add ar select currently installed components to remove C Update Ty Reinstall all program components installed by the previous setup Remove E Remove all installed components lt a InstallShield 1 Select the option Remove 2 Click Next 2 This automatically takes you to the end of the program i If the CEVIS or Siemens directory still exists after uninstalling the program it has to be deleted manually 21 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Installation 6 5 Updating SISTORE MX NVS and RemoteView software 6 5 1 From version 2 5x to version 2 80 If you upgrade to a newer version of the program the parameters of the previous version will be saved automatically
Download Pdf Manuals
Related Search
Related Contents
PDF Mode d`emploi C 4/36, C 4/36-ACS (FR) Sony D-NF421 User's Manual TU3-5-07-37-fra - Publications du gouvernement du Canada - German Testing Board BAP1502WO-CN Descale VA1 FT Copyright © All rights reserved.
Failed to retrieve file