1. PBI PLUS MAR 12 PBI PLUS PIRJOIF Mk JOE SES ee USER MANUAL USB INTERFACE FOR PROFIBUS PA HOED JOE PBIPLUSME smar www smar com Specifications and information are subject to change without notice Up to date address information is available on our website web www smar com contactus asp INDEX SECTION fs INSTALATION snie ee GR GR OE Ee Ek ae GR GE EG Ge ee 1 1 CIN ME RE N N EE OK RR RI O 1 1 NETWORK WIRING sod sd ee 1 2 WIFING IN BENE Fles ee GR Ge ins 1 3 PBEPLUS DRIVER INSTALLATION na 1 4 SECTION 2 CONFIGURATION is ete aa ana Re Ee Ge Ee Eaa NEZ 2 1 CONFIGURATION USING ProfibusView ss 2 1 CONFIGURATION USING AssetView STANDALONE sense 2 1 SECTION 3 TECHNICAL CHARACTERISTICS nnnnnnnnnnnenennneneensenreneenenennnneennnnnnnnnnnnnnnnnnnnnnnenennnennnenns 3 1 Il User Manual IV Section 1 General INSTALATION PBI PLUS is an advanced communication converter between PROFIBUS PA devices and USB ports It is intended to interface PROFIBUS PA devices such as transmitters controllers sensors actuators converters with devices such as PCs notebooks netbook or others using their USB ports PBI PLUS enable PCs and notebooks to implement high level HMI supplanting dedicated PDA programmers It allows device monitoring parameterization and configuration PROFIBUS PA network management can be implemented by using any FDT frame application Super
2. AssetView STANDALONE software 2 8 Configuration A fdtOfflineParameterize E el Eg Profibus PA Interface PBI PLUS smar 2 Off line Parameterize ih Master Settings Configure Serial Port EE DTM Slave Address 3 Serial Port Interface Us Disconnected Figure 2 13 Configuration of AssetView STANDALONE software Finally set device to online mode just right clicking on Go to online option See Figure 2 14 Then check if both interface and device TAGs become bold and Italic formatted See Figure 2 15 If affirmative it indicates that device and AssetView communication is operational and ready to be started just right click again on device to select the desired online function For more details about AssetView please consult its official manual 2 9 PBI PLUS EI MAR TEST ja E MyNetwork ce Smar Profibus Gateway PBL SMAR TEST Profibus Channel lt 126 gt LD293 LD 77 5 Add DTMIBIGER Remove OTM Block Edit TAG Go Online Go Orting Upload Parameter Download Parameter Offline Parameter nline Parameter Gompare E ontiguration Observe Additional Functions Print Description Properties Save Close Help i Figure 2 14 Configuration of AssetView STANDALONE software 2 10 Configuration ES SMAR TEST M El MyNetwork 71 58 Sma Profibus Gafewap PRI SMA FEST RES fProfibos Channel lt 126 gt 10233 10293 SHAR FES Figure 2 15 C
3. cionar novo hardware Escolha as op es de pesquisa e Instala o Procurar o melhor driver nestes locals Use as caixas de sele o abaixo para limitar ou expandir a pesquisa padr o que inclu caminhos locais e midia remov vel Ser instalado o melhor driver encontrado _ Pesquisar m dia removivel disquete CO ROM Incluir este local na pesquisa LE PET Driver N o pesquisar Escolherei o driver a ser instalado Escolha esta op o para selecionar o driver de dispositivo na lista Windows n o garante que o driver selecionado ser a melhor escolha para 0 hardware Figure 1 6 Step by step driver installation Part 2 3 step after selecting the right directory the driver will be installed and a conclusion message will be displayed See figure 1 8 Assistente para adicionar novo hardware Concluindo o Assistente para adicionar novo hardware UO assistente terminou de instalar o software para SMARA USE Controller Clique em Conclur para fechar o assistente g Voltar Concluir Cancela Figure 1 7 Step by step driver installation Part 3 1 5 PBI PLUS 1 6 After finishing this step and in order to proceed with installation the initial installation message will be prompted again No directory will need to be chosen once the right folder path will be displayed in the prompted window The created virtual serial port wi
4. ice shall have an attributed TAG See Figure 2 10 Then click OK The device will appear just below the PBI See Figure 2 11 EE TAG Biel E TAG Description ad Advanced OF Cancel Help Figure 2 10 Configuration of AssetView STANDALONE software 2 6 8 Configuration ad SMAR_TEST Io 2 MyNetwork 71 50 Smar Profibus Gateway PEL MAR TEST REEN Profibus Channel lt 126 gt LD 243 LD293 SMAR TEST Save Close Help E Figure 2 11 Configuration of AssetView STANDALONE software Then an offline parameterization in PBI shall be done Right click on PBI and choose Offline Parameterization option See Figure 2 12 Click on Master Settings option It will be prompt a interface to configured the communication port Serial Port option to be used It also be prompt the communication type Interface option that it should be set to local LOCAL option or to network NETWORK option depending on the application See Figure 2 13 2 7 PBI PLUS ESMAR TEST H MypNetwork CE Smar Profibus Gateway PEI SMAR TES ES Profibus Channel lt 126 gt LD293 L Add DTMYBlork Remove DTM Black Edit TAG o Online laine Offline Parameter Online Parameter Compare Confiquration Observe Additional Functions K Channel Functions Print Description Properties Save Close Help A Figure 2 12 Configuration of
5. ior performance and features can be achieved with PROFIBUSView and AssetView the PROFIBUS configurator and asset management system from Smar respectively This interface was designed to be lightweight and rugged at the same time thus facilitates its use PBI PLUS dimensions can be seen in the Figure 1 1 Figure 1 1 Dimensional Drawing mm 1 1 PBI PLUS Network Wiring 1 2 The interface is connected to the computer through its USB cable and then connected to the PROFIBUS PA network through pinch connector Refer to Figure 1 2 For this case the side switch must be in the NETWORK position NOTE NETWORK option disables the power supplied by the interface since the PROFIBUS channel is expected to be running and properly powered by the main control system Figure 1 2 PBI PLUS Interface Wiring in Bench Installation USB Cable Connect the dl In PC to PA PBI Plus network P 9 PROFIBUS DP 3 DP Pa ga Coupler PROFIBUS PA Figure 1 3 Wiring diagram showing the PBl interface and PA network connection e g system using DF73 PROFIBUS DP Controller IMPORTANT NOTE RELATED WITH DF95 AND DF97 CONTROLLERS FROM SMAR Due the fact these controllers have both DP and PA channels embedded and also due the fact they already have the PBI PLUS communication features is NOT possible to connect this interface in any of PA channels of these controllers For this case the side swi
6. is screen can be seen in Figure 2 2 2 1 PBI PLUS NOTE Refer to AssetView s manual for software installation details mar Asset iew FDT 1 2 0 42 File Tools Window Help ig Topology Manager Topology Diagnostics Maintenances e Reports Er Topology Open Delete Close Help Figure 2 2 Configuration of AssetView STANDALONE software 2 Insert a topology name and click OK See Figure 2 3 ad Topology Type the M ame of the Topology Pe Cancel Help Figure 2 3 Configuration of AssetView STANDALONE software 3 In the previous prompt window shows the topology name given SMAR TESTE See Figure 2 4 2 2 4 Configuration ESISMAR TEST Miel Save Close Help A Figura 2 4 Configuration of AssetView STANDALONE software Right click in the My network icon choose Add DTM and insert the PBI CommDTM It will work as a communication gateway between AssetView and the device Refer to figure 2 5 and figure 2 6 for detailed procedure 2 3 PBI PLUS EIISMAR TESTE ol xl srs a Add OTM Properties Save Close Help 4 ee Figure 2 5 Configuration of AssetView STANDALONE software Tipo de Device vers o o Fabricante 1 0 2010 12 08 Smar Profibus Gateway Ve 0 0 62 ACT 2010 11 30 Figure 2 6 Configuration of AssetView STANDALONE software 2 4 Configuration 5 Selecting PBI op
7. ll be same to be selected within the software application e g AssetView ProfibusView to allow the communication with PBI PLUS Section 2 CONFIGURATION Configuration using PROFIBUSView 1 After initializing PROFIBUSView software choose Settings option In Device combo box select the equipment to be configured Insert the real device address In the Profibus Interface option PBI PLUS USB item should be set Choose the communication port the installed virtual serial port and then choose the communication scheme LOCAL option for bench use or NETWORK option for powered PA channels Details about those communication types can be seen in the Chapter 1 Figure 2 1 shows the screen s configuration detail Settings Device Prada Address 4 Profibus Interface C DFr3 DFas DFar TCE IP PBI fsa f PEI Plus 438 Port E C Local te Network Load Device Figure 2 1 Configuration of PROFIBUS View software 2 After the initial setup done the PROFIBUSView s communication between hardware and software is established The device can be configured For more details about the PROFIBUSView software please consult its manual Configuration using AssetView STANDALONE 1 After initializing AssetView SA choose Topology option step 1 to start the setup The Topology Management will be prompted the user shall select in New option step 2 to create a topology Th
8. m A complementary list of approved operational systems is listed below Requirement Windows 7 64 bits Professional running in 32 bits compatibility mode Windows 7 64 bits Ultimate running in 32 bits compatibility mode Windows 7 64 bits Enterprise running in 32 bits compatibility mode Windows Server2008 64 bits SP2 running in 32bits compatibility mode Windows XP 32 bits SP3 Windows Server2003 32 bits SP2 Performance Specifications Electromagnetic Interference Effect Compatible with IEC61326 1 EMI immunity standard Physical Specifications Cinsuletion Galvanic insulation between Profibus and USB por S S SOS Material Injected ABS pastioendosure O O OCO OOO OSOS Dimensions 229 2 68 ma S 3 1 PBI PLUS 3 2
9. onfiguration of AssetView STANDALONE software 2 11 PBI PLUS 2 12 Section 3 TECHNICAL CHARACTERISTICS Functional Specifications Via USB 5 Vdc port Compativelible with USB 1 1 and USB 2 0 Voltage with 12 mA output 14 9 Vdc USB current 5 Vdc x 35 mA Open Voltage 15 15 Vdc Voltage with 36 mA 13 2 Vdc USB current 5 x 80 mA Output current 96 mA USB short current 142 mA Communication Standard IEC 1158 2 31 25 kbits s for Fieldbus Foundation Fieldbus and PROFIBUS PA ON Led indicates the interface is connected to USB port COMM Led indicates the interface started the communication with the device FAIL Led light when the interface is in local mode and a short circuit occurs in the device power terminals Certifications in ei lt is not certified to be used in potentially explosive atmospheres a Operation 0 a 50 C 10 a 90 RH noncondensing Storage 30 a 70 C 5 a 90 RH noncondensing PBI PLUS is a device used to interface the communication between Profibus PA devices and configuration software The software used for configuration of the devices is ProfibusView or AssetView from Smar or any software based on FDT DTM technology Licenses necessary Writing license for ProfibusView or 4 Devices fully operational Demo license for AssetView SA or and free comm DTM for any other FDT DTM based software Processor de 1 GHz 2 GB RAM 5 GB of free disk space Windows XP 32 bits SP3 Configuration Minimum Syste
10. tch must be in LOCAL position NOTE The local option enables not only the power through the interface as well as the necessary impedance control for communication with the PROFIBUS PA PBI PLUS PROFIBUS PA Device USB cable I PBI PLUS connection Figure 1 4 Interface wiring diagram for workstation to the PA device connection PBI PLUS Driver Installation When the PBI PLUS is connected to the computer s USB port a screen driver installation screen will be prompted For this installation follow the next steps 1 step in the first installation screen select the Install from a list or specific location advanced and click in Advance See Figure 1 6 Assistente para adicionar novo hardware Bem vindo ao Assistente para adicionar novo hardware Este assistente 0 ajudar a Instalar 0 software para USB lt gt Serial Ee Se o hardware tiver sido fornecido com um CD EP ou disquete de instala o insira o agora D que voc deseja que o assistente fa a Instalar o software automaticamente recomend vel Instalar de uma lista ou local espec fico avan ado Clique em Avantar para continuar altar Avan ar Cancelar Figure 1 5 Step by step Driver Installation Part 1 22 step in the next screen the user shall point the driver s folder After finding it click in Next as in Figure 1 7 1 4 Installation Assistente para adi
11. tion and then clicking OK it will be prompt a screen where the PBI tag shall be attributed EE TAG TAG See Figure 2 7 Description PBI_SMAR_TEST Address 125 Advanced OF Cancel Figure 2 7 Configuration of AssetView STANDALONE software Help LE 6 After setting the PBl s TAG it will appear just below MyNetwork The next step is adding the device to be configured To do so just right click on PBI PLUS and choose Add DTM Block option See Figure 2 8 Finalize de procedure clicking OK See Figure 2 9 ad SMAR TEST ad Mu etw amar Profibus Gateway PBL SMA Save Add OTMBlock Remove DTM Block Edit TAG o Online Go Offline Offline Parameter Online Parameter Compare E Configuration Observe Additional Functions b Channel Funckions Print Description Properties Close Figure 2 8 Configuration of AssetView STANDALONE software Help Pil ES 2 5 PBI PLUS Add x Version Vendor DT 303 2 00 2008 05 01 Simar FI303 2 00 2008 06 01 Sm r FRA 2 00 2005 05 01 Simar Frans 2 00 2008 05 01 Smar IF303 2 00 2006 05 01 Smar 2 O 2008 05 01 LD303 2 00 2008 05 01 Smar TP303 2 00 2008 05 01 Simar TT 305 2 00 2008 05 01 Simar TT423 2 00 2005 05 01 Sm r u DK Cancel ma z Figure 2 9 Configuration of AssetView STANDALONE software 7 Once created the dev