1. FOOT Tip The device supports 1 to 9 digit user IDs by default If you need to e Card extend the length of current user ID numbers please consult our gt Role User commercial representatives or sales technical support personnel 16 BIOCAM Series Products User Manual 5 3 Enrolling Card 1 On the Add User screen press W key on the Remote Control to move the cursor on the Card button and then press OK key to access the Enroll Card screen as shown in Figure 7 2 It prompts Punch Card on the Enroll Card screen Swipe your ID card properly on the Card Reader 3 If the card passes the verification the device displays a prompt kkkkkkkkkk message Read Successfully Card No as shown in Figure 8 and returns to the Add User screen The ID card number will display on the Card button as shown in Figure 9 5 4 Modify User Rights 1 On the Add User screen press V key on the Remote Control to move the cursor on the Role User button as shown in Figure 10 Note There are two types of roles respectively granted to two types of users the User and Administrator Users are only granted the roles of facial verification while Administrators are granted the access to the main menu for various operations apart from having all the privileges granted to User 2 Press OK key to change User roles Change as User or Administrator as shown in Figure 11 ES Notice Enroll Card
2. 3 Connect wires with power off If the camera does not function normally D t t wh er 1 during operation please cut off the power before investigating problem uiid ic tica BS o l DC12V 1 5A Note Wiring with power on may seriously damage the camera which i will void warranty I 4 Use the power supply included 12VDC and no lower than 1 5 amp for NE S the camera POE is also an optional power supply mode Too high or low voltage or using AC power supply may cause abnormal operation or damage to the camera and system 5 Use a standard power cord when the power supply is too far away from Please use repeater the camera and consider the voltage drop caused by long distance Contact when exceeding 80m a licensed electrician to verify proper cord length size and type 6 Read the instructions for connecting terminals and wires Any damage to the camera due to improper operation will void the warranty 7 Mount the relay equipment in the middle to avoid signal attenuation when the straight communication distance from the camera to the incoming equipment exceeds 176 feet 80m Remarks Under the POE mode if transmission distance is greater than 140 feet 60 m please use a repeater 8 Use the camera in the following conditions Ambient temperature 14F 122F 10 50 C Ambient relative humidity 10 80 RH 9 Keep the double glass clean If dirty clean with soft fabric
3. User admin Manually enter Channel Number 1 LAN Search 6 Select a device by clicking the device icon on the View Video screen the selected device is highlighted in blue see Figure 5 The software checks and shows the number of channels on the device automatically 7 Select a channel number see Figure 5 which is highlighted in blue The View Video screen shows the surveillance video of the channel in real time see Figure 6 To close the video click the corresponding channel number in blue 28 13 Accessing the Device BS Note 1 The operating system of the mobile device must be Android iOS or BlackBerry 2 Viewing videos will generate traffic For details about charges consult your network service provider 3 For details about how to use a mobile device for video surveillance see the ZKiVision User Manual Mobile Phone which is available on the disk delivered with the camera 13 3 Using the Network Video Surveillance Software The disk delivered with the camera contains the network video surveillance software ZKiVision provided by our company free of charge You can use this software to manage and monitor in real time multiple devices simultaneously You can install the ZKiVision start the ZKiVision add the devices to the system and then start real time video surveillance For details about how to use the ZKiVision see the ZKiVision Client Software User Manual which is available on the dis
4. 3 Power on the device 4 Add users to the device This function registers the faces and cards of people for whom the doors can be opened and sets user rights For details about how to add users see 5 Add User 5 Users open doors by using their faces or cards The device opens doors or generates alarms based on the user authentication results eo How to implement the video surveillance function 1 Install and power on the device For installation details see the BIOCAM Series Installation Guide 2 Use the Search tool configured for the BIOCAM Series to search the device and modify the IP address and port number of the device 3 Use a web browser mobile devices or network video surveillance software to access the device For details about the operation method see 13 Accessing the Device Appendix 3 How to change IP Address for device 1 Access the camera by using a web browser For detail please see 13 1 Using a Web Browser 2 Click System Config gt Net Setting to enter the Net Setting screen as shown as the following figure Channel EY cam 1 Speed 1 8 Zoom Focus gt Iris Value 1 255 11 Preset Auto Tour AutoPan Auto Scan Pattern PTZ Config Aux On Aux Off Local Color Adjust Remote Color Adjust Others Record Query Alarm Config Contig M S Control Panel E e System Info 2 Version Info Storage Info Ud Log A system Setting 4 Common Setting Enc
5. Month Day Y ros Setting EE Encode Setting Date Split s amp Record Setting i Snapshot Setting Time Format 24Hours y Speed 1 8 Net Setting On Storage Full Over Write 4 Mail Setting Zoom DDNS Setting ee English UPNP Setting Local Number le PPPoE Setting yi ideo Format Pap ve amp IP Privilege Setting PAL 25P iris ga NTP Setting Display Mode HDMI v FTP Setting Resolution m j RTSP Setting Value 1 255 4 i gt E PTZ Setting save Refresh Preset Auto Tour Video Capture Config Default AutoPan Auto Scan Auto Register Phone Param Set E aq Alarm Function Aux On Aux Of Alarm Input i 4 Video Detect Local Color Adjust Alarm Out Exception Deal E Advance Option Pattern PTZ Config Remote Color Adjust Others 32 Appendix Appendix 4 Statement on Human Rights and Privacy Dear Customers Thank you for choosing the hybrid biometric products designed and manufactured by us As a world renowned provider of biometric technologies and services we pay great attention to the compliance of the laws related to human rights and privacy in every country while continuing to perform research and development We hereby make the following statements 1 All of our multi bio recognition devices are for civil use only Collection of characteristic points of multi bio instead of the multi bio
6. Punch Card Add User Enroll Card H Role User Add User A po i Role User Add User 1 After entering User ID Enroll Face Enroll ID Card and Set Role press ESC key on the Remote Control to save user information and then return to Main Menu screen 2 You must enroll Face or Card or user information will not be saved 17 6 User Management 6 User Management Browse the user information including the user ID ID card FC face role Edit or delete the basic information of users On the Main Menu screen press the gt key on the Remote Control to move the cursor on the User Mgt submenu and then press OK key to enter the User Management screen shown as Figure 1 Om In User List Area users are listed in alphabetical order by User ID Press A or V key to select user and then press OK key to access the editing screen for this user and edit or delete user information 6 1 Edit User On the User Management screen press A or V key to move the cursor and select user or query user by User ID please see 6 3 Query User for The operation of Query User Next press OK key to enter the Edit User screen shown as Figure 2 The User ID cannot be modified and the other operations are similar to those performed to Add User You can re enroll your Face change ID card number and modify the Role 6 2 Delete User On the Edit User screen user information c
7. follow instructions displayed on the ActiveX download window to download install the ActiveX plugin For details about how to use a browser for video surveillance see the Web Server User Manual which is available on the disk delivered with the device 13 2 Using a Mobile Device To use a mobile device for video surveillance you must ensure that the device can be accessed from the Internet For details about setup for access to the Internet see the section How to Configure Domain Name in the Web Server User Manual which is available on the disk delivered with the camera 1 Install the surveillance software to the mobile device The software is available on the disk delivered with the camera 2 Click the icon ZKiVision on the mobile device to start the video player Figure 1 shows the initial screen of the software 3 Click The Select Add Way dialog box see Figure 2 Select an option in the dialog box The Add Device screen will display see Figure 3 4 Enter login information including Name device name Address IP address of the device Port HTTP port of the device which is port 80 by default User admin by default and Password 123456 by default 5 Click Sure button to save the configuration and return to the View Video screen which displays the added device and its channels see Figure 4 Detailed UID Sure Name 1 Select Add way Address 192 168 1 216 Two dimensional code Part B scanning
8. images does not violate privacy regulations 2 The characteristic points of multi bio collected by our products cannot be used to restore the original multi bio images and therefore no privacy issues are involved 3 We as the equipment provider shall not be held legally accountable directly or indirectly for any consequences arising due to the use of our products 4 Forany dispute involving the human rights or privacy rights when using our products please contact your employer directly Our multi bio products for police use or development tools support the collection of the original multi bio images As for whether such a type of multi bio collection constitutes an infringement of your privacy please contact the government or the final equipment provider We as the original equipment manufacturer shall not be held legally accountable for any infringement arising thereof The law of the People s Republic of China has the following regulations regarding personal freedom 1 Unlawful arrest detention or search of citizens of the People s Republic of China is prohibited infringement of individual privacy is prohibited 2 The personal dignity of citizens of the People s Republic of China is inviolable 3 The home of citizens of the People s Republic of China is inviolable 4 The freedom and privacy of correspondence of citizens of the People s Republic of China are protected by law At last we stress once again th
9. o Installation procedure for BIOCAM Series Products Mounting Paper Wall E D gt Wall Mounting ESA 1 Attach the installation template to the wall where you want to mount the camera and drill holes The Mounting Paper is 6 5 8 feet 2 2 5 m off the ground The building maintenance department or licensed building WG z uz contractor should be contacted to avoid damage to interior wall systems 12 BIOCAM Series Products User Manual and for proper mounting procedures and methods 2 Fix the camera on the wall using four screws The device can be rotated left to right so that screws can be conveniently fastened gt Top Mounting 1 Connect the steeve to the device 2 Attach the mounting paper onto the wall or ceiling where the device will be installed Drill holes according to marks on the mounting paper The building maintenance department or licensed building contractor should be contacted to avoid damage to interior wall systems and for proper mounting procedures and methods 3 Use screws to mount the steeve 4 Adjust the length of the steeve to ensure that the face recognition camera is at least6 5 8 feet 2 2 5 m off the ground note The steeve is not included The device supports three types of sleeves 15in 23in 40 cm to 60 cm 23in 31in 60 cm to 80 cm 31in 47 in 80 cm to 120 cm gt Adjust the camera to the best angle After successful installation of the device adjust the camera
10. the image area of face recognition the image area of face recognition 2 Overview Operating System Embedded Linux Video Compression l l H 264 main profile level 3 Algorithm Primary Code Stream 720P 1536 10240kbps D1 768 4096kbps adjustable Secondary Code Stream D1 768 4096kbps CIF 192 1024kbps QCIF 48 256kbps Primary Code Stream 20P 1280x720 D1 704 576 Video Resolution Secondary Code Stream D1 704 576 CIF 352 288 QCIF 176 144 PAL 1 25 frames optional Video Frame Rate NTSC 1 30 frames optional Brightness Saturation Contrast Chroma Gain Exposure Image Up Down Image Video Parameters l Left Right and Night Vision Mode adjustable Supporting local storage by using TF cards video recording and photo shooting The maximum storage capacity is 32 GB 10Base T 100Base TX Ethernet screen Supported Network TCP IP HTTP TCP UDP ARP SMTP FTP DHCP DNS DDNS NTP UPNP RTSP ONVIF and so on Function LO Working Environment DC 12V 21 5A Maximum Power 13W Consumption Working Temperature 14F 122F 10 50 C Working Humidity 10 8096 RH Installation Mode Wall mounted and Ceiling mounted Video Compression Code Rate BIOCAM Series Products User Manual 2 4 Product Appearance gt Main View e 850nm Large power infrared lamps e IPC camera Maximum Resolution e 850nm Large power infrared lamps Dedicated camera for face recognition e 7inch LCD o Infrared receiver Receives
11. 1 lists the maximum and minimum pulse width a consecutive pulse and pulse jump time time between pulses allowed by the F series fingerprint access control terminal Symbol Typical Value of Reader Pulse Width 100 us Pulse Interval Table 1 Pulse Time Data 1 Signal e White Wire won 7 7 Data O Signal Green Wire won Figure 1 Sequence Diagram Appendix 2 How to achieve Attendance Access and IPC Surveillance function e How to implement the staff attendance function 1 Install and power on the device For details about how to install the device see the B OCAM Series Installation Guide 2 Add users to the device This function will register the faces and cards of people whose attendance should be managed and set user rights For details about how to add users see 5 Add User 3 Users sign in by using their faces or cards 4 Use the ZKiVision software to download and take statistics on the staff attendance data and analyze or view the attendance reports For details about the operation methods see the ZKiVision Client Software User Manual 30 Appendix o How to implement the access control function 1 Install the function without powering on the device For details see the BIOCAM Series Installation Guide 2 Install door locks and connect the door locks to the device by using the correct connection cables For details about how to install door locks see the installation manual for door locks
12. 3 2006 x Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials for this part is above the limit requirement in SJ T11363 2006 Note 80 of the parts in this product are manufactured with non hazardous environment friendly materials The hazardous substances or elements contained cannot be replaced with environment friendly materials at present due to technical or economical constraints 34
13. 8 P S QUERY US CF ees iii a 18 T Date Time A o 19 S ACCESS Control Setting iii A eee 20 9 COMMUNICATION SEMI oo aeo o e o eee o eet dran eri aai d Lade oto esito t euet 21 AME AMEJAna FOMA dci NORRIS 22 191 Wiegand plo eH 22 10 2 Wiegand OUD UT apes m 22 10 3 Wiegand ZO DITS Describir 23 3B PICO NSS MARRE 24 Contents DR eiae rc a a 25 121 Face SUMING NT m bea 25 AZZ System Bauer eorr T ida 26 122 e cords AMONIO o nete 26 12 2 2 Device Information occcoccocncocncconcocncocnconnnonnnonononononnoncnonnnonnnnnnonanonnnnnnnnnnnnonnnns 26 IS ACCESSING Mhe DEVICES e ita 21 1351 Using a Web BrTOWSe Na calle een 2f MSZ USUI a MODDING DD iUe M L 28 13 3 Using the Network Video Surveillance Software occcocccocnconncccncconconncocnconncononononos 29 O dm E I nc te anne deen x 30 Appendix 1 Introduction to Wiegand ai iii eit ete ec ee 30 Appendix 2 How to setup Attendance Access and IPC Surveillance function 30 Appendix 3 How to change IP Address for device coooccocccocccocncoccconiconcconocooncnnnnononononanos 31 Appendix 4 How to Sync time for IPC lOevice cooccoocccocccocccocncococoncconcocncnnncncncnnncnnnnononanos 32 Appendix 4 Statement on Human Rights and Privacy cccocccoccccccnccncncnnccnncnconcnoncncnncnnnnnnnos 33 Appendix 5 Environmental Use Description oocooccoccconcoccconconnonnconcncncnnconoonnnancnnonancncnos 34 II BIOCAM
14. BIOCAM Series Product User Manual Version V1 0 Date March 2014 About This Manual This document introduces the user screen and menu operations of the BIOCAM series products For installation of the device see BIOCAM Series Product Installation Guide Important Claim Important Claim First thank you for purchasing this ID card and fingerprint hybrid terminal Before use please read this manual carefully to avoid damage to the equipment With proper use the user can improve the ease and use of the product Zkivision does not allow anyone to excerpt or copy the content of this manual in part or in full in any form The product described in the manual could include software where copyrights are shared by the licensors including our company Except for the permission of the relevant holder no one is allowed to distribute revise modify extract decompile disassemble decrypt reverse engineer lease transfer sub license the software including any other acts of copyright infringement other than the limitations by law To learn more please visit our company s website www zkivision com or the local office rn I 2 2 mm om e Due to the constant development of products the company does not guarantee the actual product to be consistent with all of the information in the document Any dispute caused by the difference between the actu
15. CAM Series Products User Manual 4 Main Menu There are two types of rights respectively granted to two types of users the Ordinary Users and Administrators Ordinary Users are only granted the rights of facial verification while Administrators are granted the access to the main menu for various operations apart from having all the privileges granted to ordinary users Press the OK key on the Remote Control to enter the Main Menu screen shown below C n 10 Es Add User User Mat Date Time Access Bn mE Wiegand Auto Test System I Any user can access the Main Menu screen by pressing the OK button on the Remote l Control if the system has no administrators After administrators are configured on the I terminal the terminal needs to verify the administrators identity before granting them access to the Main Menu To ensure terminal security it is recommended to set an administrator when I using the terminal for the first time For detailed operations see 5 4 Modify User Rights eee e u u e e e o e e e e o e o o o o o o o o o o o o o o e o o o o o e o o o e e o o e o o o o o o o o o o o oA o o o o o oA oA e m e n e e s m e n e e e e e m e e e e o eS o The Main Menu includes eight submenus B Add User Adds users for device B User Mgt Through this submenu the user information is stored on the terminal including the User ID Face and Role It will allow administrators to m
16. P ARP SMTP FTP DHCP DNS DDNS NTP ONVIF and UPNP etc e The aluminum alloy die cast design is dust proof waterproof and has anti corrosion properties e Double glass front cover for better optical isolation and mist prevention for better night viewing e Three layer shield and magnetic ring design to eliminate signal interference e The dual filter design supports the automatic night day switching to achieve a better surveillance effect O Self recovery from abnormal function with auto reconnection after network interruption e Automatically captures images during an alarm with designated email notification e Motion detection support Several alarm times are available and it is capable of remote alarm linkage Network time synchronization NTP e The HD camera supports up to 12 users browsing at the same time with four users per code stream e The dual CPUs support three cameras B One camera for surveillance B The other two cameras for face recognition e The BIOCAM series has four embedded 850 nm large power infrared lamps B Two lamps are equipped with 60 lamp cups for surveillance The radiation distance is 26 32 feet 8 m to 10 m B The other two lamps are equipped with 300 lamp cups for face recognition e The BIOCAM series supports infrared remote control The maximum operation range of the remote controller is 16 feet 5 m and the angle is 45 e The 7 inch color LCD is used to display the user screen and fa
17. Series Product User Manual 1 Instructions for Use 1 1 Distance Facial Expression and Stand Pose 1 The recommended distance Recommended horizontal distance from the user to the Face Recognition Camera is about 9 feet 3 m This is applied to height range of 5 6 feet 1 5 1 9m Facial recognition can only take place in the specified ranges left to right distance is about 1 15 feet 0 35 m and the front to rear distance is about 3 2 feet 1 m The location of the face can be adjusted based on the effect of the face image captured by the device When the face image is in the upper part of the video area move the face forward When the face image is in the lower part of the video area move the face backward Enrollment Pose lun lus During the enrollment and verification process please maintain normal facial expression and standing posture 1 Instruction for Use 1 2 Enrollment Pose During the enrollment phase display the face in the center of screen as best you can According to the prompts appearing on the device s screen focus eyes in box During face registration you many need to move from back to front to adjust the position of the eyes The enrollment poses are as follows BIOCAM Series Product User Manual 1 3 Verification Modes o 1 N Facial Verification The terminal compares the current face image collected by the camera with all face data stored in the terminal 1 Place the face in the area where the c
18. al technical parameters and the information in this document should be directed to the manufacturer A A e e m We regret any inconvenience this may cause you e e eee ee eee ee o o o o E e O E E O E O o O O O O O eB O ou eB eB eB eB eB eB eB eB O o O O E O eB O O BIOCAM Series Product User Manual Contents la td alie tuto e m De Medie Seaside Reim E UE RE EU LU LE 1 1 1 Distance Facial Expression and Stand Pose ocooccocccoccoccconcocconncononnonanonnnonncnnoncnonnonnonons 1 12 ss aue Yao se ccd De AA NUT 2 UC needs 3 1 4 Keys on the Remote COoDnLlFol icdis See Rat oe di 4 ASA A c RM AM M LULA MEE 5 2 sitos UB 0 joo Pt m 5 2 2 Product Pedes Niels o ia 5 poses val B gta ere A mzitziiiizii ifc O A IA T 24 Product ApDearaliCe uite al id i LE er eU uiui 9 AS A A E ELE I TED S A 10 2 5 EDrelmteht ote ems a dri uuo dera te A di Mo e a M ed nun 11 24 Basic PrOCedules uuo cote pareri vor scu A tae 11 3 Installation and Network ConfiguratiON oocccoccccccccccnccocncocnconcnonnnnnncnonnnononnnonnnnnnnnnnnnnnnnonnnnss 12 oT TIardware InstallatlOrtzs A da dE rendu aa 12 2 2 Network GONMECHONS a Uto d ee cecus 13 A 15 o M ile ON BIS o CEMENTERIO RECEN A A 16 E RR Nm 16 52 Enter USE Di tl a ats Metro ed 16 So EME AS o 17 9 4 MadiITy User ISIghils dudo cto aac elec adde 17 D User Management tala 18 A A eee 18 ADA US A A UR A A A A EUN ORT 1
19. amera can capture images The device automatically distinguishes face verification 2 Compare the facial image properly For details see 1 1 The Distance Facial Expression and Stand Pose The device displays the current image collected by the camera An screen as shown in Figure 1 will display 3 If the verification is successful the accepted screen will appear as shown in Figure 2 16 56 Sun Name Adam User ID 10000 o 1 1 Facial Verification Using the ID Card When face recognition of a user is difficult the user can place the ID card on the card reader to access the 1 1 face image authentication mode The system will compare the face image captured by the camera with the face image associated with the ID card 1 Place a registered ID card on the card reader 2 After card authentication is passed the system enters the 1 1 face image authentication mode At this time the face image on the screen is highlighted and a prompt 1 1 is displayed as shown in Figure 3 3 Compare the facial images For details see 1 1 The Distance Facial Expression and Stand Pose The device displays the current image collected by the camera If accepted a new screen will be displayed as shown in Figure 4 User 1D 10000 Name Adam 1 Instruction for Use 1 4 Remote Control Functions A UP WV Down lt Left F8 key Press to enter the Auto Test screen Shortcut key for Add User gt Rig
20. an be deleted 1 On the Edit User screen press the gt key on the Remote Control to move the cursor to the Delete key as shown as Figure 3 2 Press the OK key on the Remote Control then the confirm box will pop up shown as Figure 4 Press OK key to confirm and delete current user or press ESC key to cancel 6 3 Query User To flocate a user quickly from a large number of enrolled users the device enables user query by his her User ID 1 On the User Management screen press any key on the Remote Control to access the Enter User ID screen shown as Figure 5 2 Press the numeric key on the Remote Control to enter ID and press OK key to move the cursor to the desired user shown as Figure 6 18 Edit User Delete Edit User Delete RR Ce Are you sure Yes 5 Please input user ID User Management UserID Face Card BIOCAM Series Product User Manual 7 Date Time Setting Set Date Time for device On the Main Menu screen press the gt key on the Remote Control to move the cursor on the Date Time submenu and then press OK key to enter the Date Time Setting screen shown as Figure 1 02 1 Press d or gt key to select setting item Press A to go forward or V 03 to go backward and set the date and time 04 YYYY MM ODD Or press OK key to enter the Date Time input screen shown as Figure 2 Press the numeric keys on the Remote Control to en
21. at biometrics as an advanced recognition technology will be applied in many sectors including e commerce banking insurance and legal affairs Every year people around the globe have to deal with the lack of password security The biometric products actually provide adequate protection for your identity under a high security environment 33 PE Appendix 5 Environment Friendly Use Description The Environment Friendly Use Period EFUP marked on this product refers to the safety period of time in which the product is used under the conditions specified in the product instructions without leakage of noxious and harmful substances The EFUP of this product does not cover the consumable parts that need to be replaced on a regular basis such as batteries and so on The EFUP of batteries is 5 years Names and Concentration of Toxic and Hazardous Substances or Elements Toxic and Hazardous Substances or Elements NENNEN EMBNBNMNBMBMSSN o e mo cs oo re rae Chipresistor o o o o poo 5 Chipcspacitor_ x o o o o poo Pho Chipinduetor_ x e o o o po Chipdiode x o o o o poo o 2 2 EsDcomponents x o o o o 8 Sue x Jo o 1 9 peo Adapter x Jojo oe peto Sww o o oy eoe e 2 o Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ T1136
22. ce recognition results The operations are BIOCAM Series Products User Manual convenient and the screen is simple e The BIOCAM series supports TF cards e The BIOCAM series can generate voice notification to alert users of the face recognition and registration process as well as face recognition results e The maximum face capability is 400 e The BIOCAM series supports face based video recording and photo shooting Recorded videos or photos are uploaded to the PC as events 2 3 Technical Parameters des M12 Do Mi28men mm 6mm _ eem Lux IR lamp off Minimum Illumination O Lux IR lamp On IRLamp IRLamp 2 2 built in 42 mil dot matrix infra red lamps in 42 mil dot matrix infra red 2 built in 42 mil dot matrix infra red lamps Effective Projection 26 32 feet 8 10m o Loudspeaker Su o TO Effective Projection Angle Motion Detection Detection Detecting area that can be set to anyshape si area Detecting area that can be set to any shape can be set to any shape Face Recognition Image Resolution Support 640x480 Face Recognition ZKFace VX7 0 Algorithm Camera High resolution infrared and color camera si High resolution infrared and color camera si infrared and color camera Two large power infrared lamps that can be dd turned on during face IHE hice mami Displayer 7 inch LCD that is used to Znen LCD that is used to display
23. e of the after sales service personnel from our company 25 BIOCAM 44177 APM 12 2 System Information You can check the storage status as well as version information of the device through the Information option On the System Settings screen press the W key on the Remote Control to move the cursor to the Information submenu and then press OK key to enter the Information screen or display the Records Information in default 12 2 1 Records Information The number of enrolled users will be displayed on the Records screen The total face capacity used capacity total record capacity and used S i Face 400 capacity are graphically displayed as shown in Figure 1 7 Used 45 Free 355 Record 100000 Used 18 Free 99982 12 2 2 Device Information Menu Information On the Information Screen press the V key to move the cursor on the E22 Device Name BIOCAM 300 NS Device Serial Number 0316140300113 Device item and then display the Device Name Serial Number MAC ane a VIAL e55 E a Cd Address Face Algorithm Firmware Vendor and Manufacture of device Face Algorithm ZKFace VX7 0 As shown as Figure 2 Firmware Ver 8 0 0 build 427 Vendor ZKSoftware Inc Manufacture 2014 01 21 18 04 19 26 13 Accessing the Device 13 Accessing the Device You can access the camera by using a web browser mobile device or our company s network video surveillance software BS Note Before acces
24. e suspended It is easy to install and convenient to operate It is suitable for indoor use It can be used for all weather monitoring and face recognition in for example offices or banks where the video surveillance attendance and access control systems are integrated The following describes how the attendance access control and video surveillance functions of the BIOCAM series are implemented Please see Appendix 2 How to achieving Attendance Access and IPC Surveillance function 2 2 Product Features e The mixed facial recognition algorithm features a large capacity and fast recognition speed e The product integrates two high resolution infrared and color cameras 2 Overview e The product adopts an ergonomic industrial design e The infrared optical system is highly adaptive to the environment and can identify faces even at night e The BIOCAM series in standard configuration is equipped with simple access control functions including the door sensor door switch lock control and Wiegand input e The BIOCAM series in standard configuration supports TCP IP based communication and connection across different network segments or gateways e The web server management mode is integrated with the PC software management mode to make management highly flexible e The BIOCAM series supports the H 264 Main Profile e Dual code stream suitable for various networks e Supports many protocols such as TCP IP HTTP TCP UD
25. he Door Sensor does not apply NO The door can be set as a passage mode in a normal condition NC Means that the door is closed in the normal working condition Alarm Delay s Detection to the abnormal door sensor state The door sensor will generate an alarm signal after a period of time this time is the door sensor alarm delay The functioning value is 1799s 20 BIOCAM Series Product User Manual 9 Internet Connection Settings On the Main Menu screen press the W key on the Remote Control to move the cursor on the Comm submenu and then press OK key to enter the Communication Settings screen When the terminal communicates with the PC over Ethernet you need to check the following settings Menu Communication IP Address 192 168 1 88 Subnet 299 299 299 0 Gateway 0 0 0 0 Device ID l Comm Key 0 IP Address Displays the current IP address The IP address is 192 168 1 88 by default Subnet Displays the current Subnet Mask The subnet mask is 255 255 255 0 by default Gateway Displays the current Gateway The gateway is 0 0 0 0 by default Device ID This parameter is used to set the ID of device from 1 to 254 If the RS232 RS485 communication is adopted enter the device ID on the software communication screen Comm Key To enhance the security of attendance data a password for the connection between the terminal and PC can be set Once the password is set the PC with the termi
26. ht OK Save and Confirm key Backspace and Delete key Return and Cancel key Janc 3DEF T9 Input Keypad dum e Guso Numeric Keys 0 1 2 t PURS an L o AVS 3 4 5 6 f 8 9 0 JA ZKT key Input switch T9 input type key Press to create space Oins If the device is in an inactive state you can press any key on the remote control to wake up the device BIOCAM Series Products User Manual 2 Overview 2 1 Product Description The BIOCAM series integrates the attendance system access system and IP camera IPC It also offers attendance access and video surveillance functions This series of products is configured with a LCD remote controller to facilitate man machine interaction and offline management external peripheral Wiegand input lock control door sensor and display design to ensure that the device can independently complete all operations in offline status including extraction of human faces comparing and identifying human faces and registering information Attendance Function The BIOCAM series is a day night embedded IPC that provides facial recognition based attendance function This IPC is embedded with the high speed face recognition algorithm It can extract compare and identify the face of whoever enters the video area of the camera in real time The video area is 8 11 feet 2 5 m to 3 5 m away from the camera and is 6 Y 8 feet 2 m
27. ile Administrators are granted the access to the main menu for various operations apart from having all the privileges granted to Ordinary Users 5 1 Enrolling Face Focus eyes in box 1 On the Add User screen press OK key to enter the Face Enrollment screen as shown in Figure 2 2 On the displayed face enrollment screen as shown in Figure 3 eyes show in the box according to the voice prompts See 1 2 Enrollment Pose 3 If the facial image is enrolled successfully the system will display a prompt Focus eyes in box message and automatically return to the Add User screen as shown in Figure 4 Add User 5 2 Enter User ID UserID 1 The device automatically allocates an ID starting from 1 for every user in lt Card sequence If you use the ID allocated by the device you may skip this gt Role User section 1 On the Add User screen press W key on the Remote Control to move Please input user ID the cursor on the User ID button and then press OK key on the Remote e Control to access the Enter user ID screen shown as Figure 5 2 3 Tip The user ID can be modified during initial enrollment but once enrolled it cannot be modified 2 Press the Numeric Keys on the Remote Control to enter user ID and press OK key to confirm lf a prompt message User ID exist is displayed Add User enter another ID Press ESC key to cancel and return to Add User screen shown as Figure 6
28. ing is not successful The valid value scope is 70 120 The higher the threshold the lower the FAR while the opposite is true if the FRR is higher 1 N Threshold This parameter is used to set the threshold of matching between current face and the facial template enrolled in the FFR terminal in the 1 N verification mode If the similarity between current face and the facial template enrolled in the FFR terminal is larger than this threshold the matching is successful otherwise the matching is not successful The valid value scope is 80 120 The higher the threshold the lower the FAR and the higher the FRR and vice versa The recommended thresholds are as follows Threshold FRR 1 N 1 1 Medium Medium 82 75 Low High 80 70 Exposure This parameter is used to set the exposure value of the camera The default value is 300 Quality This parameter is used to set a quality threshold for the facial images obtained The FFR terminal accepts the facial images and processes them by adopting the facial algorithm when their quality is higher than the threshold Otherwise it filters these facial images mis 1 After setting press the gt key on the Remote Control to move the cursor on the Save button and then press OK key to save the settings 2 NOTE Improper adjustment of the Exposure and Quality parameters may severely affect the performance of the FFR terminal Please adjust the Exposure parameter only under the guidanc
29. k delivered with the camera F Pu m ALLES 45 EL i 00 44 48 29 BIOCAM Series Product User Manual Appendix Appendix 1 Introduction to Wiegand Wiegand26 is an access control standard protocol established by the Access Control Standard Subcommittee affiliated to the Security Industry Association SIA It is a non contact IC card reader screen and output protocol Wiegand26 defines the screen between the card reader and controller used in the access control security and other related industrial fields Wiegand26 helps standardize the work of the card reader designers and controller manufacturers The access control products manufactured by our company are also designed by following this protocol Digital Signals Figure 1 is a sequence diagram in which the card reader sends digital signals in bit format to the access controller In this sequence diagram Wiegand follows the SIA s access control standard protocol for the 26 bit Wiegand card reader one pulse time ranges between 20us and 100us and the pulse jump time ranges between 200us and 20ms Data1 and DataO are high level larger than Voh signals until the card reader prepares to send a data stream The asynchronous low level pulse smaller than Vol generated by the card reader is sent to the access control panel indicated by the saw tooth wave as shown in Figure 1 through Data1 or DataO Data1 and DataO pulses will neither overlap nor be generated synchronously Table
30. nal access can obtain the attendance data provided an additional password is entered The default password is O that is no password Once a password is set enter this password before connecting the PC software with the terminal otherwise the connection is unsuccessful 1 to 6 digit passwords are supported Orn 1 On the precondition that the device is connected to the network you can use a browser to log in to the device and modify the IP address of the device For details please see Appendix 3 How to change IP Address for device 2 After setting press the gt key on the Remote Control to move the cursor to the Save button and then press OK key to save Communication Settings 21 10 Wiegand Format 10 Wiegand Format On the Main Menu screen press the gt key on the Remote Control to move the cursor to the Wiegand Format submenu and then press OK key to enter the Wiegand Input screen Menu Wiegand Input Standard Wiegand 26 bits WG Output Bit Counts 26 Pulse Width 100 e rn Pulse Interval 1000 Input P Card No 10 1 Wiegand Input Wiegand Input Format The system has a built in Wiegand 26 bits format Bit Counts Display the length of the current Wiegand input format Pulse width Refers to the width of the Wiegand pulse in microseconds The default value scope of the pulse width is 1 1000 Pulse interval Refers to the interval of the Wiegand pulse in mic
31. ng items 2 Before installing the device connect the camera to computer by means of a patch cable Modify the IP address of IPC For detail please see Appendix 3 How to change IP Address for device If your PC IP address is in a network section different from an IPC address please set it to the same network section as IPC such as 192 168 1 87 3 Log in the device through client software or browser to check that the video functions normally In initial state the User name is admin and Password is 123456 For detail please see 13 1 Using a Web Browser 4 Adjust the code stream and other video parameters 5 Modify the network parameters of the camera and reboot the device 6 Repeat Step 2 T Revisit the camera through client software or browser to verify that the video functions normally 8 Install the camera and adjust the camera angle to the appropriate area 9 Use the remote control to register users on the device including registering human faces cards and setting user rights and implement user management 10 Compare and authenticate users 11 Visit the camera through client software or browse for video monitoring 11 3 Installation and Network Configuration 3 Installation and Network Configuration 3 1 Hardware Installation o Installation Notes 1 Read the installation guide prior to installation 2 Check for any missing items against the packing list If missing items please contact your supplier
32. ode Setting E Mail Setting DDNS Setting UPNP Setting J PPPoE Setting IP Privilege Setting 4 NTP Setting FTP Setting RTSP Setting 0 PTZ Setting g Video Capture 4 Config Default ga Auto Register Phone Param Set E a Alarm Function Alarm Input 4 Video Detect 4 Alarm Out Exception Deal E Adwance Option System Config Face Recog Logout Net Setting r 1 Net Setting f IP Address 1 Subnet Mask Gateway j ONS Device Name rcp Port I HTTP Port Max Co current 3 Modify the IP Address as needed and then press Save button to save settings 3 BIOCAM Series Product User Manual Appendix 4 How to Sync time for IPC device 1 Access the camera by using a web browser For detail please see 13 1 Using a Web Browser 2 Click System Config gt System Setting gt Common Setting to enter the Common Setting window 3 Click SyncPC button to synchronization time 4 Click Save button to save and then the system will pop up the Save successful prompt box Click the OK button to close the prompt box Record Query Alarm Config System Config Face Recog About Logout Channel EY cam 1 Control Panel Common Setting E e System Info 2 Version Info i 03 Si mui 9 Storage Info System Time 2014 03 06 v 10 51 51 Save Time SyncPC Y d Log Common Setting Date Format vear
33. odify or delete the user information B Date Through this submenu the date can be set B Access Through this submenu the parameters of the electronic locks and related access devices can be set B Comm Through this submenu related parameters for communication between the terminal and PC including the IP address Gateway Subnet Mask Device ID and Comm Key and so on can be set B Wiegand Type Through this submenu Wiegand Input and Output format for device can be set B Auto Test The device automatically tests the image collection effect of a camera It tests whether a camera can capture face images properly by displaying a face image in both color and black white modes B System Face Settings including the 1 1 Threshold 1 N Threshold Exposure and Quality Adjust the cameras on the device to the optimal collection status View the system information including the device capacity and device information 15 5 Add User 5 Add User Press the OK key on the Remote Control to enter the Main Menu Press Add User the OK key again to enter the Add User screen shown as Figure 1 zu UserID 1 User ID Enter a user ID 1 to 9 digit user IDs are supported by default mm Face Enroll a user s face ID card Enroll a user card Role Set the rights of a user A user is set to Ordinary User by default and can also be set to Administrator Ordinary Users are only granted the rights of facial verification wh
34. roseconds The default value scope of the pulse width is 1 10000 Input content Refers to the content input upon successful verification You can select the User ID or Card No as the input 10 2 Wiegand Output Menu Wiegand Output Save WG Input Standard Wiegand 26 bits JUL Failed ID 0 Site Code Pulse Width Pulse Interval 1000 Output P Card No Wiegand Format The system has two built in formats Wiegand 26 bits Failed ID Refers to the value output by the system upon verification failure The output format is subject to the setting of Wiegand Format The default value scope of Failed ID is 0 65535 Site Code The site code is used for customized Wiegand format The site code is similar to the device ID but the site code is customizable and can be duplicated among different devices The default value scope of the site code is 0 255 Pulse Width Refers to the width of the Wiegand pulse in microseconds The default value scope of the pulse width is 1 1000 Pulse Interval Refers to the interval of the Wiegand pulse in microseconds The default value scope of the pulse width is 1 10000 22 BIOCAM Series Product User Manual Output Refers to the content output upon successful verification You can select the User ID or Card Number as the output 10 3 Wiegand 26 bits Description The system has a built in Wiegand 26 bits format The composition of the Wiegand 26 bit
35. s format contains 2 parity bits and 24 bits for output contents User ID or Card Number The binary code of 24 bits represent up to 16 777 216 0 16 777 215 different values 1 2 25 26 Even parity bit User ID Card Number Odd parity bit Definition of Fields Even parity bit Judged from bit 2 to bit 13 The even parity bit is 1 if the character has an even number of 1 bits otherwise the even parity bit is O User ID Card Number User ID Card Number Card Code 0 16777215 bit 2 bit 25 Bit 2 is the Most Significant Bit MSB Odd parity bit Judged from bit 14 to bit 25 The odd parity bit is 1 if the character has an even number of 1 bits otherwise the odd parity bit is O For example for a user with user ID of 12345 the enrolled card number is 0013378512 and the failed ID is set to 1 1 When the output is set to User ID the Wiegand output is as follows upon successful verification 00000000000110000001110011 Even parity bit User ID Binary code of 12345 Odd parity bit 2 When the output is set to Card Number the Wiegand output is as follows upon successful verification 11100110000100011110100000 Even parity bit User ID Binary code of 0013378512 Odd parity bit 3 he Wiegand output is as follows upon verification failure 00000000000000000000000010 Even parity bit Failed ID Binary code of 1 Odd parity bit uote If the output content exceeds the scope allowed for the Wiegand format the las
36. signals from the Remote Control gt Side View Fixed Support 2 Overview 2 5 Terminal Connections IB IL aNd LOSMNI lt 009MNI Power screen Connected to the power adapter The voltage of the power supply for the device is 12VDC and the current is not less than 1 5 amp POE is also an optional power supply mode Do not use other power supplies otherwise the camera may be damaged Network screen 10 100M self sensing Ethernet screen through which the device can be connected to various network devices such as switches routers or hubs Audio output Connects with external play devices such as a loudspeaker Reset button Press this button for more than 5 seconds with power on then the camera will recover to default configuration After the device is powered on for 40 seconds default IP address is 192 168 1 88 user name admin and password 123456 10 BIOCAM Series Products User Manual 2 6 Screen Set Up Time Week User Photo 4 Current image captured by the camera Date Time Current time will display Both the 12 hour and 24 hour time systems are supported Week Current week date is displayed User Photo Display the photo that is automatically taken by the device after user authentication is accepted Current image captured by the camera Human face or image captured by other cameras Date Current date will display 2 7 Basic Procedure 1 Unpack and check for missi
37. sing the device connect the camera to the network and power supply Then check whether the network screen indicator is in normal status to ensure that the network connection is normal 13 1 Using a Web Browser 1 Start the browser Enter the dynamic domain name or IP address for example http 192 168 1 88 in the address bar and press Enter The following login screen is displayed User Name Password Language Ed save Password Login 2 Enter the User name and Password The first time you use the device the User name is admin and Password is 123456 Click Login button to enter the preview screen where you can start video surveillance Web Server Windows Internet Explorer Ge je e 192 168 1 88 Ga Live Search e Web Server ur d P n mi Ae Ww E Record Query Alarm Config System Config Face Recog Logout Channel EY cam 1 Default Grade Speed 1 8 Zoom Focus 17 Iris Value 1 255 114 mi Preset Auto Tour ON Auto Pan Auto Scan Pattern PTZ Config Aux On Aux Off Local Color Adjust 1192 168 18 75 1 2791Kbps 51 Remote Color Adjust Others LS Note If you use a browser to access the device for the first time you need to download and install the ActiveX ActiveXPlugin ocx Enter the device s IP address in the Address Bar and press Enter key and the ActiveX download 21 BIOCAM Series Products User Manual window will popup Then
38. t several bits will be adopted and first several bits are automatically discarded For example the user ID 888 888 888 is 110 100 111 110 110 101 111 000 111 000 in binary format Wiegand26 only supports 24 bits that is it only outputs the last 24 bits and first 6 bits 110 100 are automatically discarded 23 BIOCAM Series Product User Manual 11 Auto Test On the Main Menu screen press the gt key on the Remote Control to move the cursor to the Auto Test submenu and then press OK key to enter the Auto Test screen Auto Test The camera automatically captures the existing human face then uses the black white and color display modes to automatically test whether the camera collection function is available and whether the collection effect is good 24 BIOCAM 44177 APM 12 System Settings On the Main Menu screen press the gt key on the Remote Control to move the cursor onto the System submenu and then press OK key to enter the System Settings screen Menu Settings PP amenos 99m 1 N Threshold 8 Exposure EE NN ao Quality Information 12 1 Face Setting 1 1 Threshold This parameter is used to set the matching between current face and the facial template enrolled in the FFR terminal in the 1 1 verification mode If the similarity between current face and the facial template enrolled in the FFR terminal is larger than this threshold the matching is successful otherwise the match
39. ter Date Time and press OK key to save and then return to the Date Time Setting screen 2014 03 03 16 04 01 2 After setting press gt key to move the cursor to the Save button and 02 02 15 press OK key to save and then return to the Main Menu screen 03 03 Or press ESC key to cancel operation and return to the Main Menu a screen DO ES Note After the date and time of the device are changed the setting will be synchronized to the IPC If the date and time are not synchronized in time you can log in to the device using a browser and then manually synchronize the time For detail please see Appendix 4 How to Sync time for IPC device 19 BIOCAM Series Product User Manual 8 Access Control Settings Set Up Through the Access menu you can set the parameters of the electronic locks and related access control devices On the Main Menu screen press the gt key on the Remote Control to move the cursor on the Access submenu and then press the OK key to enter the Access Setting screen Menu Lock Delay s Door Sensor Lock Delay s The device controls the time to open electronic locks Functioning value for 1 10s Door Sensor This allows time to be designated after which time an alarm will sound The functioning value is 1 99s Door Sensor Mode There are three options none NONE normal open NO normal close NC Press W key to select Door Sensor Mode NONE Means t
40. to 2 5m high Access Function The BIOCAM series integrates the security surveillance system with the intelligent video analysis system at the bottom layer With the intelligent analysis technology the BIOCAM series screens out key information from massive video information and provides the information to the administrators for further analysis and judgment The embedded system mode not only improves the stability of the device but also substantially reduces the cost for implementing intelligent analysis The front end high speed recognition algorithm can analyze and process video streams on the device which greatly reduces the system delay and enhances usability After the BIOCAM series is connected to a control access device it can extract and compare human faces to determine whether the door should be opened or closed and whether an alarm should be generated The video surveillance function is linked with the access control function to implement the lock control operations Video Surveillance Function The BIOCAM series uses the mega pixel CMOS sensor The projection angle of the infrared lamp is wide which delivers outstanding night vision capability The optimized H 264 coding algorithm ensures a clearer and smoother video transmission effect The embedded web server allows users to implement real time monitoring and remote control on the front end camera by using an internet browser The BIOCAM series can be mounted on a wall or can b
41. to the best angle to implement face recognition and video surveillance Detailed adjustment methods are as follows 1 Press the F8 key on the Remote Control until the Auto Test screen appears 2 Designate a person about 5 5 feet 1 7 m tall to stand at a predetermined spot approximately 9 feet horizontal distance to the Face Recognition Camera 3 Rotate the device up down left and right to ensure that the facial image displays inside the green box on the Auto Test page as shown in the figure on the right to adjust the camera to the best angle 3 2 Network Connection Connect by Ethernet Cable 1 Use Ethernet cables to connect the device to network or directly to a computer 2 Connect the power supply to the device 3 In the Start menu select All Programs gt Accessories gt Command Prompt and input the ping command to 13 3 Installation and Network Configuration the device address e g type in ping 192 168 1 88 f Request timed out does not pop up the device is successfully connected to network LZS Notice 1 The default IP address is 192 168 1 88 and the default HTTP port is 80 If a change to the IP address or port is needed refer to Network Setting in WEB Server User Manual 2 If the device is in a network section different from the computer refer to How to Configure Domain Name in WEB Server User Manual for the connection using different network sections 14 BIO