1. Soft Keys Scrolls one file list page up Scrolls one file list page down GUY none Delete selected file from non volatile memory Nn D O D C lt Back to main mask Page 12 of 21 ISOBUS VT Basic Masks 2 6 Auxiliary Mask Auxiliary mask contains editor to map input to function LInmapped Unmapped Unmapped Figure 7 Auxiliary mask Soft Keys l Scroll page up 2 Scroll page down 3 none 4 Save mapping configuration none 6 Back to main mask Usage 1 Use rotary to select wanted function 2 Press enter to focus input 3 Select with rotary wanted input 4 Press enter to validate selection Now VT tries to connect input to function If this fails VT shows alarm mask 5 Save configuration User Manual Page 13 of 21 How to change values 3 How to change values 3 1 3 2 3 3 3 3 1 ISO 11783 6 standard has four different kind of input fields for user Field types are Boolean List Number String These fields can be selected with rotary if they are enabled ESC key aborts editing at any time Input Boolean field This field has been implemented as square box Enter key chances value Examples o Enabled false Disabled true Input List field Input list field is invisible container that can contain objects To change value of the input list field object press enter when the object 1s selected Now the object is framed Use ro
2. safety and warning requirements of the application are met The products described herein including without limitation product features specifications designs availability and pricing are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice Offer of Sale The items described in this document are hereby offered for sale by Parker Hannifin Corporation its subsidiaries or its authorized distributors This offer and its acceptance are governed by the provisions stated in the Offer of Sale elsewhere in this document or available at www parker com Page 2 of 21 ISOBUS VT Table of Contents 1 Introduction 5 1 1 Keys and display areas 6 2 Basic Masks T 2 1 Main Mask 7 2 2 Settings Mask 8 2 3 Information Mask 10 2 4 Datelime Mask 11 2 5 Files Mask 12 2 6 Auxiliary Mask 13 3 How to change values 14 3 1 Input Boolean field 14 3 2 Input List field 14 3 3 Number input 14 3 3 1 Edit 14 3 3 2 Number editor 15 3 4 String input 16 Information notes 18 5 Alarms 19 5 1 Alarms that can occur in system pool 19 6 Splash screen 21 6 1 Parker Splash screen 21 User Manual Page 3 of 21 Page 4 of 21 ISOBUS VT Introduction 1 Introduction A virtual terminal VT is an electronic control unit ECU consisting of a graphical display connected to an ISO 11783 network that provides the capability for an ECU implement to interact with operator When Worki
3. MI vawsco ISOBUS VT ISOBUS Virtual Terminal User Manual HY33 4010 IB UK Vansco Electronics Oy Parker Hannifin Corporation Electronic Controls Division PO Box 86 Tiilenly j nkatu 5 FI 30101 Forssa Finland Office 358 3 412 4400 Fax 3583 433 5157 http www parker com ecd ecdinfo parker com Copyright 2009 Parker Hannifin Corporation All rights reserved No part of this work may be reproduced published or distributed in any form or by any means electronically mechanically photocopying recording or otherwise or stored in a database retrieval system without the prior written permission of Parker Hannifin in each instance FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH PERSONAL INJURY AND PROPERTY DAMAGE This document and other information from Parker Hannifin Corporation its subsidiaries and authorized distributors provide product and or system options for further investigation by users having technical expertise It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog Due to the variety of operating conditions and applications for these products or systems the user through its own analysis and testing is solely responsible for making the final selection of the products and systems and assuring that all performance
4. age 21 of 21
5. mask contains information about VT Virtual Terminal Can High a Can Low edo v Supply de ad ds Board Temp 2a E Can address Sta era p al 2 6 0 0 Hw versi an dd ie ie Serial number IB LE JB IR SE ELS pleit Asked El r 009 10 06 Serv Cel THEE Figure 4 Information mask Variable data Can High 2 25V 2 75V Can Low 2 25V 2 75V Supply Voltage Board temperature 30 C 80 C Can address 38 default Static data SW version HW version Serial number Manufactured Service code input field for service code Soft Keys Page 10 of 21 Back to main mask ISOBUS VT Basic Masks 24 DateTime Mask DateTime has input fields to change date time and time format Format Time 12 Hour Mi Boe 2 a sa Vi Oe SEE Figure 5 DateTime Date e Number input fields for date according to Format Format e DD MM YYYY day month year e DD YYYY MM e MM YYYY DD e MM DD YYYY e YYYY MM DD e YYYY DD MM Time e lt Hour gt lt Minute gt 12 Hour Soft Keys t Back to main mask User Manual Page 11 of 21 Basic Masks 2 5 Files Mask Virtual terminal can save pools into VT s non volatile memory Also auxiliary mappings can be stored Use rotary to select file Version IS0 name HMitronD 4OO00DODOZESSSF U oooo0000004000000 1 FONODNNONNANANNNNN SFAOSOSFETEF TEE ooo0000004000000 BEP465r 244656570 O40000002 E696 Fe Figure 6 Files mask
6. ng Set WS detects the VT in ISOBUS network it can send an ObjectPool to the VT or download the saved pool from VT s non volatile memory If the WS is active on the VT screen all soft key and editing button presses are sent to the WS The WS can modify its own pool at the VT at any time Parker s ISOBUS VT is designed for vehicle use only and indoor use with high temperature range Certification of the Parker s ISOBUS VT guarantees that it is compliant with other ISOBUS products on the market ObjectPool is a group of objects that describes user interface seen on the VT screen User Manual Page 5 of 21 1 1 Keys and display areas Soft Key Designator Data Mask area This four directional button can be used instead of rotary encoder to move between different input fields on screen ESC key is used to cancel operation in input fields so the value is not changed Figure 1 Keys and display areas Page 6 of 21 Introduction ACK key is used acknowledge alarm display in case there is no softkey on alarm mask page Rotary encoder is used to move between different input fields on the screen and change values of these fields This has also push button which acts as Enter key Softkeys ase used to select the virtual key on the right hand side of the screen Change working set key is used to change between active implements on the
7. or step backward P Editor cursor step forward A Line step up ISOBUS VT How to change values e Line step down Usage Use editor keyboard with rotary and enter to input value User Manual Page 17 of 21 Information notes 4 Information notes VT informs user with message boxes The box is seen the lower left of the screen certain time even mask or working set is changed 17 40 09 Pool load fai led Jut of Memory 01 10 20095 Figure 10 Message box Page 18 of 21 ISOBUS VT Alarms 5 Alarms Alarm Mask informs operator about problems or failures in the workingset Operator must acknowledge this message with available softkeys or by ACK button If Alarmask is on the screen it is not possible to change workingset with change workingset button 5 1 Alarms that can occur in system pool User Manual N Board temperature Coo lS Ea Display will See lq EG Figure 11 Board temperature alarm mask Auxillary assignment failed Figure 12 Auxiliary assignment error mask Page 19 of 21 Alarms value out af range Press Enter to continue Figure 13 Number Edit error mask Page 20 of 21 ISOBUS VT Splash screen 6 Splash screen 6 1 Parker Splash screen Splash screen is the first visible picture after start up and is shown for 3 seconds ISOBUS Virtual Terminal SO 11783 certified ENGINEERING SUCCESS Figure 14 Splash screen User Manual P
8. screen and to go to VT s home screen ISOBUS VT Basic Masks 2 Basic Masks 2 1 Main Mask Main mask is the first visible mask after start up Figure 2 Main mask Soft Keys l To Settings Mask 2 To Information Mask To Date time Mask To Files Mask 5 To Auxiliary Mask 6 59 09 2U7 No action Shows date amp time U9 User Manual Page 7 of 21 Basic Masks 2 2 Settings Mask Setting mask contains controls to change display audio settings and information that are sent to ECU Electronic Control Unit on request To change values on mask see section 3 Language Decimal Hight Mode Distance Area Wool ume Mass Pressure Force System Figure 3 Main mask Soft Keys Increase volume KA Decrease volume 4 3 Volume test 4 Increase brightness 5 Decrease brightness I 6 1E Back to main mask Units with possible values Language e en this list changes according to connected devices Decimal e point or comma Night Mode e inverts display Page 8 of 21 ISOBUS VT Basic Masks User Manual Distance e Metric e Imperial Area e Metric e Imperial Volume e Metric e Imperial e US Mass e Metric e Imperial e Tons pounds Temperature e Metric e Imperial Pressure e Metric e Imperial Force e Metric e Imperial System e Metric e Imperial e US Page 9 of 21 Basic Masks 2 3 Information Mask Information
9. tary to change new value Press enter to accept new value Examples Parker wT Selected Number input There are two ways to change number input values Edit Press enter when the object is selected The object will become framed and active Use rotary to increase or decrease the value You can use also keys Press enter to accept value Page 14 of 21 ISOBUS VT How to change values Examples e Active re Disabled 3 3 2 Number editor When you double click with enter key selected number input field the VT opens number editor mask Hin Has z0 00 Ems aS OK JESC 5 gt OMe S456 Poot Figure 8 Number editor mask Accept new value Cancel Mask Objects Soft Keys l 2 e Min Displays minimum possible input value e Max Displays maximum possible input value e OK Accept value e ESC Cancel e Editor cursor step backward e gt Editor cursor step forward e 1 9 and Editor keyboard Usage Use editor keyboard with rotary and enter to input value If value is invalid VT will show alarm mask User Manual Page 15 of 21 How to change values 3 4 String input Figure 9 String editor Soft Keys Accept new string string in edit field 3 Clear edit text field 4 Backspace 5 Newline ME 6 Space Edit buttons in string keyboard Page 16 of 21 0E Accept new value ESC Cancel editing Backspace New line Space d Editor curs

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書(PDF)  Notice d'emploi et manuel d'installation Gebruiksaanwijzing en  LEO B CBB 3 230 L02 LEO B CBB 3 230 L04 LEO B CBB 3 120 F02  User Manual - Industrial Network Controls, LLC. Home Page  Sommario  安全データシート  Eurotech Appliances Computer Hardware EmbeddedDNA EuroTech DuraChassis User's Manual  