Home

EK20-IDJ3 USER MANUAL

image

Contents

1. SPOSTA GIU ESCI CONFIGURAZIONI SPOSTA SU SPOSTA GIU RESET STRINGA 12 DI 31 INVIA o E LETTORE ESCI activate on the READER the SCAN STATE 0 Read one or more TAG LED Y EDG Press LOG DOWNLOAD A window show the transfer advance LOG TRANSFERRED r E READ LOG Activate on the READER the RADIO STATE LOG SCARICATI 1 SCARICA LOG ESCI Now the first install is complete You can create new projects following the procedure in 4 0 4 0 HOW TO CREATE A NEW PROJECT Open the window COMMUNICATION PARAMETERS Select the SETTINGS MODE Mark ENABLE COMMUNICATION AT START UP r PARAMETRI DI COMUNICAZIONE PORTA sa COM1 Porta di comunicazione m 18200 M MUDALITA LOG RICARICA LISTA PORTE T Jefe worcerroni SUM M DALITA IMPOSTAZIONI CONNESSIONE 0 gt LETTORE DI CONFIGURAZIONE 7 ATTIVA COMUNICAZIONE ALL AVVIO ARCHIVE OF CONFIGURATIONS Open the window PROGRAM Choose the CURRENT LANGUAGE IDONE R permits to create an ARCHIVE of your PROJECTS Sy PROGRAMMA DATABASE CONFIGURAZIONI c ProgramD ataXIDONE SIDONE R D atabase Filess amp MRA Cassonetti mdb CREA NUOVO DATABASE APRI FILE CARTELLA SALVATAGGIO LOG CALI serssgi
2. The tipical reading distance depends from the TAG type and size EPC GEN2 Tip 800 mm 2 0 HOW TO OPERATE WITH IDJ3 READER The READER operates in 3 different states STANDBY STATE SCANNER STATE RADIO STATE STANDBY STATE The LED YELLOW and GREEN are turned off The current absorption is reduced at a minimun value SCANNER STATE From the STAND BY STATE pressing the key the READER enters the SCANNER STATE The YELLOW LED turn on The READER exec the UHF scan for the set TIME SCAN from 1 sec to 3600sec When a TAG is detected the LED YELLOW flash At any TAG detected the READER verify if was just read in this session If it was never read so will be saved in the LOG memory The buzzer emit a sound and the TIME SCAN is retriggered If the TIME SCAN is expired the READER enters the RADIO STATE The pass in RADIO STATE can be made also pressing the key The LED YELLOW turn off RADIO STATE Entering the RADIO STATE the LED GREEN turn on The RADIO became active for the period set in RADIO TIME 1 sec to 200 sec They are four possible situations 1 No LOG has to be transmitted and the READER is out the RF field After the RADIO TIME the READER enters the STANDBY MODE 2 No LOG has to be transmitted and the READER is in the RF field After the RADIO TIME the READER enters the STANDBY MODE 3 Some LOGs has to be transmitted and the READER is out the RF field The LED GREEN flashes The buzzer emits a sound After the RA
3. TECHNOLOGY DOC 435 R04 EK20 IDJ3 USER MANUAL IDJ3 here named READER is an UHF RFID reader oriented to applications of TRACEABILITY Features Operates with the most popular TAGs UHF EPC Gen2 18000 6B 18000 6C Long range reading tip 80cm Operates with only one key Three LED EB canner running Greens RADIO connection BB Battery Low Records 2500 LOGs in CODE TEXT mode Connectable wireless by RADIO UHF Standard or BLUETOOTH Can create an User Database using IDONE_R sofware Rechargeable LIPO battery IP65 box shock resistant Complete of the IDONE R software freely downloadable from www zetanetweb com download zetanet htm Compatible with our mobile readers IDTRCM IDGIANO and fixed IDTRCF DONER ATTIVITA PROGRAMMAZIONE TAG UNIQUE QS TK5557 amp HIT CLIENTE INDUT RFID PROGETTO ATTIVITA R E IDONE R APPLICAZIONE INFO SU IDONE R ESCI Bj cows LETTORI 8 09 29 1 feb205 INDEX HOW TO READ A TAG HOW TO OPERATE WITH IDTRCM READER IDONE R FIRST INSTALL HOW TO CREATE A NEW PROJECT LOG MANAGEMENT HOW TO CREATE AN USER DATABASE SET CURRENT DATE ON A READER SET A DEVICE NUMBER ON A READER HOW TO REDUCE IDONE R BATTERY AVAILABLE MODELS TECHNICAL SPEC HOW TO UPGRADE THE FIRMWARE AND THE LANGUAGE ON IDTRCM 1 0 HOW TO READ
4. x Fk 20 upLoader Comm Part Hom Upload Language Upload Program Baud 19200 n 8 1 x UpLoad Program Device Address fo v Echo Suppress UpLoading 2 28 10 2014 1338 Idle _ Pt 4 14 IDONE_CLOUD Another solution is to collect the LOG by RADIQ in real time and transmit them by INTERNET CLOUD LOG transmitted to the SERVICE CENTER in bur Personal Area Offer a full protected access by a personal P sword This operation need an Internet Access Point ili your location and a Microserver to collect the Logs from the READERS INOUT RFID s r l Via Milano 14 H 20064 Gorgonzola ITALY Phone 39 02 95138 139 Fax 39 02 95 158 694 Email info inoutsrl it Web www inoutsrl it 15
5. 22 10 13 35 DATA INOUT RFID INOUT RFID INOUT RFID INOUT RFID INQUT RFID INOUT RFID INOUT RFID N DISPOSITIVO OPERATORE ivi TUTTI DISMESSO INIZIO FINE INIZIO ICODE ICODE ICODE ICODE ICODE ICODE ICODE 0009C41966 0009041 95F 0009041958 0009041935 0009041935 0009C4193C 0009C4193C RECORD IN LISTA 8 OSCILLOS TESTER F SALDATO ACNE SRL ACNE SRL RAMA SRL FINE RAMA SRL RIFIUTI 10 02 2015 10 14 15 INOUT RFID UHF EPC GEN2 0000000000 C Documents and Settings amp dminDocumentiNIDONE R Log Filess amp TTIVITA LOG mdb Take SALVA LOG PER EXCEL AGGIORNA LEGGI LOG APRI FILE DI LOG SELEZIONE CAMPI desde ESCI CONFIGURATION CONFIGURATION associated to the received LOG DATE TIME DAY MONTH YEAR HOUR MINUTES SECONDS of the READ TAG operation COMPANY CUSTOMER associated READER DEVICE NUMBER TAG TYPE The read TAG type TAG DATA A 16 characters field for EPC UHF FILTERS Filters the Logs in function of Configuration Date from to Reader number SAVE LOG IN CSV OR XLS FORMAT Press SAVE LOG CSV FORMAT to archive the Logs for use with EXCEL OPEN LOG FILE Press OPEN LOG FILE to visualize previous recorded Logs FIELDS SELECTION Press FIELDS SELECTION to choose the items to be viewn in the Log area 2 SELEZIONE CAMPI CI CONFIGURAZIONE DATA ORARIO SOCIETA OPERATORE LETTORE DIREZIONE TIPO TAG UID CAMPO DATI CARA
6. EENT TESTO TESTO 15 ESPORTA FILE CS I TESTO TESTO 16 ES TESTO TESTO 17 Sesto SY TESTO 9 TESTO 18 SALVA ESCI 10 Press NEW Insert the data into the fields Connect the READER to read the UID CODE to be associated Press READ UID the read EPC CODE appear in the window Press SAVE The User Data are viewn in the riepilogative window Repeat the operation for all the USER to be inserted into the DATABASE r r 2 Hem Oo amoun c e PROGETTO a PROGETTO a CONFIGURAZIONI ICODE X 0 Ie LETTORE CONFIGURAZIONI ICODE LETTORE CODICE UID D0 09 CA 2F 8C LEGGI UID ICODE 150 15693 v LETTURA DATI OK SALVA CODICE UID 00 00 00 00 00 LEGGIUID ICODE 150 15693 v LETTURA DATI OK 5 ANNULLA s ANNULLA NOME PISDLI FRANCO NOME NUDVO Nuovo CELLULARE 333333333333 NEES CELLULARE ELIMINA ELIMINA MODIFICA MODIFICA NOMI CAMPI NOMI CAMPI ESPORTA FILE CSV ESPORTAIRLE UID CAMPO 1 CAMPO 2 OOOSCA2FIC ABCD ROSS LUIGI 0009 2 AMRA PISOLI FRANCO 0009041958 BBCC NERI GIUSEPPE 0009 2 2 CIMOLI FABIO Open the window LOG MANAGEMENT Press FIELD SELECTION Mark the new fields generated by the CUSTOMER DATABASE you want to visu
7. charging a RED LED is lighted When is charged the RED LED is off In case of LOW BATTERY the RED LED flash The READER turn off 11 0 AVAILABLE MODELS EK20 IDJ3 R Model with antenna UHF and RADIO UHF Suffix B BLUETOOTH interface Optional RADIO UHF PEN a i S The RADIO PEN UHF is quoted a part 13 12 0 TECHNICAL SPEC RFID FREQUENCY POWER LOG MEMORY circular buffer LOG MEMORY circular buffer ACOUSTIC WARNING LED BATTERY CHARGER DATA TRANSMISSION 19200 8 N 1 OPERATING TEMPERATURE DIMENSIONS WEIGHT 13 0 To upgrade the FIRMWARE Launch the program EK20 UPLOADER UHF 868 Mhz EPC GEN2 Max 24 dbm 2500 records in LOG FORMAT CODE TEXT 32 chars YELLOW SCAN STATE GREEN RADIO STATE RED CHARGE STATE Buzzer YELLOW SCANNER GREEN RADIO BB BATTERY CHARGE Main Adapter 12VDC 1A time to full charge max 5 hours RADIO UHF max 200mt in free air BLUETOOTH OPTIONAL 20 C to 60 C LIPO 7 4V 1000mah rechargeable 125mm x 70mm x 23mm 170g HOW TO UPGRADE THE FIRMWARE ON IDJ3 that you find in the IDJ3 CD folder Set the RADIO COM PORT and the bit rate 19200 Press UPLOAD PROGRAM Will appear the window RISORSE DEL PC Select the file IDJ3xxxx BIN Set the address of the connected READER Activate on the READER the RADIO STATE LED Y EDG Press START and wait the end of programming On the READER will appear
8. DIO TIME the READER enters the STANDBY MODE 4 Some LOGs has to be transmitted and the READER is in the RF field The LED GREEN flashes and the LOGs are transferred to the HOST At any transferred LOG the RADIO TIME is retriggered The LED GREEN become fixed At the end of LOG transfer after the RADIO TIME the READER enters the STANDBY MODE The passage in STANDBY STATE can be made also pressing the key DEFAULT VALUES obtained by pressing the key for 12 seconds DEVICE NUMBER 00 BAUD RATE 19200 N 8 1 TIME SCAN 60 sec TEMPO RADIO ON 60 sec TIME CANCEL FILTERS imin RADIO SID 1 RADIO CHANNEL 7 O LED Y 3 LED G D LED Y 3 LED G LED Y LED G LED Y LED G LED Y LEDG 3 0 IDONE R FIRST INSTALL The first install is very important because creates the correct environment need by the system So we have made a simplified procedure to start the first install INSTALL IDONE R ON PC Connect to the web site www zetanetweb com download zetanet htm Download the file IDONE R_5xx_Setup exe Exec the file and follow the instructions to the end of install An icon will appear on your Pc d RADIO COM PORT INSTALL Insert the RADIO PEN UHF into an USB connector on your PC The PC begin to install the new device Wait for the completion of the install of the assigned COM PORT rz Click on the icon to launch IDONE R Will appear a request Press OK IMPOSSIBLE TO LOAD THE MAIN DA
9. IONA TUTTI SELEZIONA TUTTI DISSELEZIONA TUTTI POSIZIONE CONFIGURAZI D Unique 11 Mifare 12 UHF SPOSTA SU SPOSTA GIU RESET 0 Ie LETTORE 5 0 LOG MANAGEMENT The Log transfer can be set in two mode 1 SETTINGS MODE 2 LOG MODE PARAMETRI DI COMUNICAZIONE PORTA COM13 USB Serial Port iv MODALITA LOG RICARICA LISTA PORTE Ja gt N DI LETTORI Tus MODALITA IMPOSTAZIONI CONNESSIONE gt LETTORE DI CONFIGURAZIONE ATTIVA COMUNICAZIONE ALL AVVIO ESCI 1 SETTINGS MODE This mode is normally used for the CONFIGURATION activities and for the LOG TRANSFER on a single READER at time Select the READER device number to connect Press LOG DOWNLOAD and wait for the end of log tranfer r 5 READ LOG LOG SCARICATI 1 SCARICA LOG ESCI To visualize the received LOGs select LOG MANAGEMENT The current LOG FILE is displayed in red 1J GESTIONE LOG FILTRI CONFIGURAZIONE TUTTE INVENTARIO INVENTARIO INVENTARIO MANUT CALDAIE MANLIT CALDAIE MANUT CALDAIE MANUT CALDAIE 10 02 2015 10 02 2015 10 02 2015 10 02 2015 10 02 2015 10 02 2015 10 02 2015 DATA DA ianovzoto 10 02 2015 TUTTI CONFIGURAZIO DATA ORARIO SOCIETA LETTORE DIREAONE mePor a amp up cawopan sd 10 11 40 10 12 27 10 12 41 10 12 58 10 13 12 10 13
10. POSTA SU SPOSTA GIU CONFIGURAZIONE INVIA LETTORE ESCI CONFIGURATION SETTINGS Here are descipted the admitted parameters by the READER In the window CONFIGURATION MANAGEMENT press CONFIGURATIONS e CONFIGURAZIONE Unique CONFIGURAZIONE TAGS amp MODI OPERATIVI V UNIQUE 05 TK5557 EM4102 TITAN HITAG 1 5 SRIX SLI UHF EPCGEN2 MIFARE 1K MODO DI LETTURA e CODICE TESTO DIREZIONE DISABILITATO ABILITATO LISTA CAUSALI DISABILITATO O ABILITATO TESTI DA DB DISABILITATO ABILITATO RISERVATO 1 DISABILITATO ABILITATO RISERYATO 2 9 DISABILITATO ABILITATO RISERYATO 3 DISABILITATO O ABILITATO RISERYATO 4 DISABILITATO ABILITATO RISERYATO 5 DISABILITATO O ABILITATO RISERYATO 6 DISABILITATO ABILITATO RISERYATO 7 DISABILITATO ABILITATO INDIETRO AVANTI gt TAG CHOICE Select the TAG type UHF EPC GEN2 READ MODE Select TEXT Press SAVE SEND CONFIGURATIONS TO THE READER Press SEND TO READER Appears the window CONFIGURATION SEND Mark the CONFIGURATION you want send to the READER Activate on the READER the RADIO STATE Press SEND and wait for the end transfer BLUE BAR Now the READER is ready to operate r 3 74 SEND CONFIGURATION mm CONFIGURAZIONI GESTIONE DATABASE SELEZIONA TUTTI DISSELEZ
11. TABASE A DEFAULT ONE WILL BE CREATED mam Compile the fields as in this example and choose the Tag UHF to be read Press OK DATABASE Per creare un nuovo database compilare i campi qui sotto NOME DATABASE TEST NOME CLIENTE TEST NOME PROGETTO TEST NOME CONFIGURAZIONE TEST TIPO TAG Open the window COMMUNICATION PARAMETERS Set SETTINGS MODE Set the CONFIGURATION READER Select the RADIO COM PORT Press CONNECTION r Q PARAMETRI DI COMUNICAZIONE mm PORTA Q COM4 USB Serial Port 18200 x MODALITA LOG RICARICA LISTA PORTE MODALITA IMPOSTAZIONI 0 LETTORE DI CONFIGURAZIONE DISCONNESSIONE ESCI V ATTIVA COMUNICAZIONE ALL AVVIO Open the CONFIGURATIONS window Press SEND TO READER In the window CONFIGURATION SEND mark the Configuration to send TEST Activate on the READER the RADIO STATE Press SEND and wait for the end transfer BLUE BAR r r 95 GESTIONE CONFIGURAZIONI 23 INVIO CONFIGURAZIONE PROGETTO TEST CONFIGURAZIONI NOME SALVA SELEZIONA TUTTI DISSELEZIONA TUTTI P CONFIGURAZIONE _ ANNULLA POSIZIONE CONFIGURAZI 0 TEST 0 TEST NUOVA ELIMINA MODIFICA NOME SPOSTA SU
12. TTERE SEPARATORE SALVA ESCI CHAR SEPARATOR serve to export the logs in csv format 2 LOG MODE IDONE R via the RADIO PEN UHF start a continuous scanning of the READERS Don t serve any command by the operator the LOGs will be transferred from the READERS present in the RF field Mark LOG MODE Set the N of readers to be interrogated from 1 to 99 Start the connection A mimic panel show the current state of any READER GREY DISCONNECTED OR NOT IN RF FIELD CONNECTED LOG transfer running The N of received LOGs is also shown 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 6 0 HOW TO CREATE AN USER DATABASE In the window LIST press USERS to open the window USERS MANAGEMENT Choose the CONFIGURATION on which to be create the USER DATABASE Press DB FIELDS NAME to open he window USER FIELDS TEXT Insert a name the fields will be used by the DATABASE Ex COMPANY NAME CELL Press before SAVE and next EXIT r GESTIONE UTENTI p r TESTI CAMPI UTENTE PROGETTO a 55 CONFIGURAZIONI ICODE X 0 Ie LETTORE PROGETTO a oe CONFIGURAZIONI 1 CODICE UID 00 00 00 00 00 LEGGI UID ICODE ISO 15633 v ANNULLA TESTO D DITTA TESTO 10 Nuova TESTO 1 Nome sm ELIMINA TESTO 2 CELLULARE TESTO 12 MODIFICA TESTO 3 TESTO 13 TESTO 4 TESTO 14
13. alize in the LOG area Press SAVE sumo NE Rm CONFIGURAZIONE DATA ORARIO CELLULARE SOCIETA _ OPERATORE V LETTORE DIREZIONE V TIPO TAG UID CAMPO DATI CARATTERE SEPARATORE 9 GESTIONE LOG FILTRI CONFIGURAZIONI DATA DA DATA A N DISPOSITIVO ICODE gt 29 07 2015 0500872015 TUTTI RECORD IN LISTA 1 20 conriguns DATA onama terrone Teo tas wo ICODE 05 08 2015 11 03 55 ICODE 0009 2 2 DDEE CIMOLIFABIO 888888888888 ICODE 05 08 2015 11 09 25 ICODE 0009 1958 NERIGIUSEP 555555555555 ICODE 05 08 2015 11 09 33 ODDSCAZFIC ABCD f ROSSILUIGI 4444444444444 CAL sersNgiancarloNDocumentsNDO NE RSLog Filessa Log 2015 08 mdb LOG SCARICATI AGGIORNA APRIFILEDILOG 9 LV LOG Jets SELEZIONE CAMPI 11 7 0 SET CURRENT DATE ON A READER Set the READER number and press SEND DATA amp ORA LETTORE DATA OFA 8 0 SET DEVICE NUMBER INTO A READER Insert the ACTUAL ADDRESS and the NEW ADDRESS to be set in the READER Press SEND ch N DISPOSITIVO INDIRIZZO ATTUALE INDIRIZ20 NUOVO TESTO GISPOSITIMVO 9 0 HOW TO REDUCE IDONE R Normally the end user application don t use all the functions available on IDONE R The user can reduce them activating only those really needed Digit the Reserved Code Will appear a windo
14. ancarloNDocumentsNDONE R Log Files SELEZIONA CARTELLA IMPOSTAZIONE FILE DI LOG O PER ANNO PER MESE gt 1 ITALIANO INGLESE FRANCESE LINGUA CORRENTE ITALIANO CREATE YOUR PROJECT Press CREATE NEW DATABASE Insert the DATABASE We do suggest to detail this name so that during a next search will be easily reknown as the CLIENT as th PROJECT Insert the CLIENT NAME and the PROJECT NAME J DATABASE gt Per creare un nuovo database compilare i campi qui sotto NOME DATABASE TEST NOME CLIENTE ITEST NOME PROGETTO TEST NOME CONFIGURAZIONE TEST TIPO TAG LOG FOLDER SETTINGS Appear the DEFAULT of the LOG FILE folder Users MYNAME Documents IDONE R Log Files If you want to assign a new root press CHOOSE FOLDER and insert the new root Select in LOG FILE SETTINGS the log saving mode any MONTH or any YEAR The logs will be automatically saved in a folder so defined DATABASE NAME_YEAR_MONTH Es AMRA_CASSONETTI_2015_3 Any LOG will be inserted in the folder in function of the recorded date also for month deferred transfer CARTELLA SALVATAGGIO LOG C Users CAD Documents IDONE F Files SELEZIONA CARTELLA IMPOSTAZIONE FILE DI LOG D PER ANNO PER MESE ATTENTION Incase of CREATE NEW DATABASE as here descripted the correct LOG FILE will be created a
15. fter the first received log CUSTOMER SETTINGS Select CUSTOMER in the CUSTOMERS amp PROJECT S windows Insert the Customer data and press SAVE r GESTIONE CLIENTE SOCIETA INDIRIZZO Via Perino 14 CITTA Vergola PROVINCIA Milano NAZIONE TELEFOND FAX EMAIL CONTATTO NOTE PROJECT SETTINGS Select PROJECT in the CUSTOMERS amp PROJECTS windows r GESTIONE PROGETTO CLIENTE AMRA CODICE PROGETTO 7892 NOME FORMATO LOG CODICE e CODICE TESTO LOG FORMAT CODE TEXT Into the LOG string will be recorded in TAG DATA the full EPC 12 or 16 byte The PROJECT CODE is sent to all the READERS configured with this Project Grants that only the log comprise into this project will be recorded We suggest don t modify this CODE CREATE YOUR CONFIGURATION For any PROJECT on IDJ3 you can create one CONFIGURATION Select CONFIGURATIONS Press NEW Insert a name in the NAME window and press SAVE The name appears in the list To delete modify or move a name in the list select the name and exec the appropriate commands Press SAVE 09 GESTIONE CONFIGURAZIONI PROGETTO Cassonetti rifiuti Zona Indust NOME Pj CONFIGURAZIONE ANNULLA NUOVA ELIMINA MODIFICANOME S
16. w CLIENT SETTINGS where you can select the functions to be active Any reduction is associated to one PROJECT 9 IMPOSTAZIONI CLIENT BARRA LATERALE PAGINA LOG _ PANNELLO TAG 7 SELEZIONE CAMPI PANNELLO CONFIGURAZIONI SALVA LOG PER EXCEL E IMPOSTAZIONE DIVISIONI CAMPO DATI 7 APRI FILE DI LOG STAMPA PANNELLO DATABASE LISTA UTENTI ILISTA LETTORI V PANNELLO IMPOSTAZIONI 4 DATA amp ORARIO a e pni SELEZIONA REPORT DI STAMPA PANNELLO LOG _ CANCELLA LOG DA LETTORE OPZIONI V GESTIONE LOG V INVERTI CODICE UID UNIQUE ABILITA GESTIONE UTENTI ILISTA UTENTI UNICA PER TUTTE LE CONFIGURAZIONI LISTA LETTORI UNICA PER TUTTE LE CONFIGURAZIONI 4 VISUALIZZA STATO LETTORI PANNELLO OPZIONI PROGRAMMA V COMUNICAZIONE V4 VISUALIZZA MODALIT IMPOSTAZIONI Close the program IDONE R and restart it to visualize the new one 12 d IDONER a a Ug 9 s ere IMPOSTAZIONI DATA amp ORA ES _ 8 44 SCARICA LOG B GESTIONE LOG E NN PROGRAMMA Q PARAMETRI DI COMUNICAZIONE APPLICAZIONE INFO SU IDONE R 17 35 04 2015 10 0 BATTERY The READER operates from a rechargeable LIPO battery 1000mah The recharge is made through the connector positioned in the bottom side The 12VDC power supply to charge the battery is comprised in the furniture When the battery is