1. power to start the machine 3 5 2 Turn on the master power switch on the backboard 3 5 3 Turn on the emergency switch clockwise turn in the front side of the mainframe 3 6 Operation Enter operation condition after debugging and no abnormalities found 3 6 2 Treatment Program Selecting Interface UX I A Tratamiento de Pigmentaci n There are 6 treatment programs that could be selected a Hair removal b Skin rejuvenation c Pigmentation Therapy d Vascular Therapy e Acne Therapy f RE Wrinkles Therapy Select different treatment programs by clicking
2. professional treatment room take effective eye protecting measure 3 7 Treatment Advice 3 7 1 Hair Removal Strong pain follicular orifice will become a little reddish with a burning smell Caution for arms lips and legs hair removal avoid pigmentation bv over high energv According to the growing period of hairs growing period maturation period rest period 3 times of treatment will remove the hair completely Parameter control Long pulse width long interval suitable energy 3 7 2 Skin rejuvenation Strong pain under the patient limit reddish redness disappear in 10 minutes No suggesting repeat operation Parameter control Long pulse width long interval high energy 3 7 3 Acne scar Patient would have a strong pain under the limit of patient Pigmentation will decline in 3 7 days Parameter control Long pulse width short interval high energy 3 7 4 Vascular redness Using high pulse width on the basis of easing the skin Parameter control Long pulse width long interval suitable energy 3 7 5 Freckle pigmentation strong pricking for the first treatment under the tolerance of the patient One minute after receiving emitting there will be slight reddish which will fade away in 10 minutes for someone special maybe 30 minutes Punctuate pigment will appear on the surface of skin and will be metabolized in 3 7 days Parameter control Long pulse width short interval medium energy Special Attentio
3. 50J cm2 Pulse Amount 1 6 Pulse Width 1 10 ms Pulse Delay 1 100 ms Repeat frequency 1 4s RF working time 50 2500 ms Spot size 8x40mm Filters 530nm 560nm 640nm 2 pcs 690nm N W 50kg Voltage 230V 10 50 60Hz l For the sensitive and dark skin there might be delayed reaction in 3 Equipment Structure 24 48 hours therefore do not raise the energy casually Adjust the parameter value according to the whiteness of skin The whither the higher endurance of the skin is For dark skin please pay more touch screen attention to use long interval and suitable energy of parameter value V Safety Notice 4 1 Safety of E light The equipment takes maximum consideration of the safety of both operator and operatee in the designing the following are some safe measures of it emergency stop Circuit self checking after machine starting Using filter light guide crystal strong pulse light comes out only se ia Designed with independent safety circuit electricity could be shut down automatically when the IPL power is to high Emergency stop switch shut down the power in emergency Key switch to avoid starting the machine by any people Use high quality engineering plastic frame preventing electricity creepage Alarm All strong pulsed light device may cause hurt by improper handling Operators should keep vigilant and take necessary protection measures according to the manual Patient Carry out the treatment in the
4. E light Svstem Model No LT S205 MANUAL Index I BRIEF INTRODUCTION LAT CIO aaa 2 Application 3 System Self checking 222222 2 4 Equipment Clossificalion 2 5 Equipment Consist Specification amp Accessory Lisl 7 II STANDARD TREATMENT PROCESS III OPERATION INSTRUCTION V SAFTEY NOTICE 4 1 Safety of E light 17 4 2Safety of Electricity amp Machinery T_T 18 VI TABOO INSTRUCTION Vi ATTENTIONS AFTER TREATMENT Vi WARRANTY POLICV 20 3 No stimulating food or pigmentarv food as chocolate coffee no smocking no drinking 5 No scratch in case of scabbing 6 Make a water replenishing care in 10 days Vil Warranty Policy The warranty of equipment 1s one year from the date of supply During the warranty period we undertake to repair free for the equipment supplied against all manufacturing and workmanship defects The standard of operation and environment should comply with the product specification and user manual The warranty does not extend to any equipment that a Malfunctions caused by abused operation b Malfunctions caused by other artificial factors like move or tear down in proper motion or collision etc c Malfunction caused by uncontrollable natural force d Energy reduce caused by wet environment and dust e Consumable parts of the equipme
5. e skin 2 8 5 Observing the reaction of skin while operating 2 9 Cold compress Keep gel coating for 20 minutes after operation ending carry out cold compress in obvious slight reddish reaction till reddish fading away 2 10 Cleaning Clean the gel with cold water coat corresponding cosmetics 2 11 Treatment Course Skin Rejuvenation Program 30 45 davs time 4 times course Hair Removal Program 2 3months time 3times course 2 12 Special reminding 2 12 1 Ask the client before treatment is there a allergic or not 1s there a bad reaction before for similar operation fill the Client File concretelv Adjust the parameters on the basis of full acquaintance concretelv Adjust the parameters on the basis of full acquaintance of the condition of patient Inform the patient the possible reaction in operation before operating 2 12 2 In large area treatment or long time continuous operating the water inside the equipment will warm up and the handpiece will be hot interrupt the operation to refresh the water or leave the water cool down to continue operating 2 12 3 Refresh the circulating water in one month use purified water or medical distilled water 8 RF T RF energy adjusting e r i AB i E 1 i 770007 cooling degree adjusting Pulse 2 Pulse 3 Delay 1 Delay 2 Pulsel working time ofthe first pulse 1 10ms adjustable Pulse 2 and Pulse 3 sub pulse width 1 10ms adjustable Delay1 1st pulse delay interval b
6. etween the 15 pulse and 2 pulse Delay 2 and Delay 3 interval between two pulses RF working time 50 2500ms adjustable Pulse amounts ll interval between two spots l 4s adjustable back L water circulating status 3 6 3 Treatment Program Operation Interface III Operation Instruction 3 1 Before starting the machine 3 1 Accessories connecting 3 1 1 Connect the handle and filters 3 1 1 1 Put the E light handle on the hanger 3 1 1 2 Connect the E light handle to the connecting port on the back board of the machine tightly GRF 7 e A te A TA BS IPL energy display Click ES and ed to increase or decrease IPL energy 3 1 2 Check the water holes of the backboard make sure the water outlet hole is plugged well 3 2 Water infusing 3 2 1 pull out the plug of the water inlet hole insert the water funnel 3 2 2 infuse water till water spill out from the spillway hole 3 3 Checking 3 3 1 Make sure there 1s no water leaking 3 3 2 Make sure there is no moisture or wet for electricity connecting parts 3 3 3 Make sure the key switch is in the off position 3 3 4 Make sure the emergency stop switch is in the on position 3 4 Starting the equipment 3 4 1 Connect the power cord turn on the key switch 3 4 2 Double confirm there is no leaking of water circulation fold the protective cover by turning it right 3 5 Debugging 3 5 1 Make sure water and electric circuit is correct connected then turn on the
7. f the two polars two parts on the probe must cling the skin together when operating c When the operation finishes release the blue button first then move the probe out of the skin 3 6 4 System Setting interface HR 000000 RF 000000 Seleccionar seen Idioma Sonido Calibracion Pantalla a charging status 5 simmering indicator 00000 counter of shots for the current treatment standby click standby the lamp will be lightened off Click standby when treatment finish to turn off the handle Pesto ready click ready the lamp of the handle will be lightened up and light will be simmered by press the button on the handle 3 6 4 RF Operation Interface 2 7 Allergic test Emit 2 or 3 light spots in the bottom of ears in safe parameter observe for 3 minutes Effect do not continue to operate if there is an allergic phenomenon 2 8 Operation Carry on the operation with a suitable parameter to the patient ATTENTION 2 8 1 Inform the patient that there will be a slight pricking in operation before operating to avoid panic 2 8 2 Start the operation with a low energy grade adjust the parameters in operating while asking the feeling of the patient 2 8 3 Move the light spot by one spot overlapping the upper 1 3 part of the previous spot No emitting one area repeatedly otherwise may cause inflaming or burns 2 8 4 The handpiece should touch the skin vertically no over pressing or leaving th
8. han the skin VI Attentions After Treatment 1 Not using irritative makeups 2 No hot water face wash or sauna in 7 days 3 No stimulatin J JO od or pigmentary food as chocolate coffee no smoking no drinking Operator wearing protective glasses Treatment room marked the treatment room clearly with in B Reflector and filter operating of IPL To ensure to the safe use of the equipment please read the following Instructions carefully gt No one except technician authorized by the manufacture could gt dismantle or repair the equipment especially for the power source handle high voltage electricity inside Voltage rating 220V Maintaining the equipment after disconnecting the power cord Keep the handle clean all the time do not let the gel leaking into the handle In case leaking of the handle do not start the equipment already started turning off immediately No emitting light to one area repeatedly otherwise may cause inflaming or burns and may leave pigmentation Alarms of Strong IPL gt IPL may hurt the eye or cause burns or fire take all necessary prevention measures before operating Emitting too much light to one part may burn the skin which may cause pigmentation Do not watch the IPL light directly from the handle even wearing protective glasses C Sapphire wave guide 2 Technique Specification IPL Power 1000W RF Intense Electric Energy 5MHz Light Energy 15
9. machine carrv on the self checking for 5 10 seconds then continue the operation 4 Svstem Classification Electric shock protection Gradel BF Grade Corrosion prevention liquid ordinarv Do not use the machine in the environment mixed of flammable narcotic and air or nitrogen oxide mixture 5 Equipment Consist Specification amp Accessory List 1 Equipment Consist 1 1 Mainframe A Power supply system B Microcomputer system C Monitor D Cooling System 1 2 E light Handpiece A 14 RVI ANOR OAR a oll Ar RAO AMA atv A MILCIISC DUISCO 118 Mt SOUTCC ACNON Lamp A 4 2 Elect ricity amp Machinery Safety O Keep all the boards closed open the board may bring danger O There is high voltage electricity inside some parts still carry electricity even after turn off the power therefore do not dismantle the backboard without under supervising by our technicians O Do not move the equipment by pulling the handpiece Oo Do not use the equipment in inflammable and explosive environment O Do not use alcohol or acetone before treatment O Do not start operating before the handpiece dry enough after clean the handpiece or other parts of the equipment VI TABOO The following people are not suitable to be operated by the machine 1 pregnant high blood pressure heart attack diabetic 2 allergic to IPL 3 open wound parts 4 people who could not avoid strong sun light 5 scar birthmark or mole higher t
10. n water inlet handle connector 4 Accessory List RF Handpiece 6 KeySwitch pe 2 inthe filterbox 8 Goggles for Patient pair 1 lin the lateral foam box I 10 Water funnel pc l in the lateral foam box l User Manual in the lateral foam box II Standard Treatment Process 2 1 Form filling Fill in the blanks of the Client File confirm the treatment program and remind the client pav attention to some points before and after treatment 2 2 Face cleaning Clean the face with gentle face cream for 3 minutes Remind clean the hands of operator and the handpiece with bromogeramine 2 3 Preheating Start the equipment after face cleaning preheat for not less than 3 minutes without lighting the xenon lamp 2 4 Shaving Shave the unwanted hair of the treatment area 2 minutes 2 5 Gel coating Coating the gel evenly 2 3mm on the skin Effect light guide cooling anaesthetisin Attention no coating on eyes eyebrows lips 2 6 Eye protection Operator wear the safety goggles Patient close the eyes wear professional safety goggles or cover the eyes with eye patch RF working time repeat frequency 3 6 4 1 Usage of RF handle a Coating the gel evenly 1mm on the treatment area b Chose different probes for different treatment area 15mm eyes 20mm forehead face 30mm face body c cling the probe to the skin rightly Attention a Do not press the blue button before the probe clinging the skin b Both o
11. nt handpieces I Brief Introduction E light applies three core technology IPL RE and epidermis cooling It combines the advantage of IPL and RF in one hand the skin absorbs IPL energy selectively and the skin also absorbs RF energy on the other hand the RF surface touch cooling technology removing the discomfort and complications by high heat of IPL Therefore the effect and safety of E light makes a breakthrough 1 Principle Applying the technique of IPL and Bi polar Radio Frequency the equipment acts on the entire skin corium and connective tissue stimulates the collagens of different depth to realign and grow then gets treatment effect Bio polar RF release energy at the same time with the selective absorption for the skin to light energy various pathological tissues of corrum and epidermis creates Photothermolysis effect Since light energy is far below conventional IPL the pigment tissue and vascular pathological tissue of the corium and epidermis would absorb more energy without injuring the epidermis and then remove these pathological tissues better and get the effect 2 Application 1 Hair removal including dark skin 2 Skin rejuvenation 3 Acne treatment 4 Removing freckle age spots sun spots pigmentation troubles etc 5 Removing red face red capillarv and bottle nose 3 Svstem Self checking The circuit of svstem entering the self checking situation when the machine starts leave the