1. USER S MANUAL amp Warranty Card PURE SINE WAVE HOME UPS gt z lt 4 oz q LI gt N Silicon ower Systems 222 3rd Cross Kullappa Layout N R Colony Airport Road Cross Bangalore 17 Telefax 080 25270544 E mail siliconups rediffmail com Silicon ower Systems Do ower Systems INTRODUCTION Dear Customer Congratulations for entering into the most PRIVILEGED and SATISFIED Customer list of SILICON POWER SYSTEMS by purchasing our product Now you are assured of reliable amp safe power source for your computer systems and other peripheral as well as lighting loads in your building Silicon Sine wave Home UPS System manufactured by Silicon Power Systems undergo stringent quality checks SILICON SINE WAVE HOME UPS is designed and developed using state of art micro controller based technology The product is designed to provide you efficient performance requiring minimal care and maintenance at your end This manual will help you familiarize with its salient features controls and safety instructions along with understanding the basic working of the product and its maintenance and use Any suggestions regarding the product are always welcome we will definitely take into consideration We hopefully expect more repeat order and references above all a long lasting relationship with you Thanking you and assuring you of our best services at
2. Dotted lines indicates UPS connection Arrow lines Indicates Bypass connection The Home UPS Systems can be bypassed by connecting the output plug which connects the load to the Home UPS System directly to the socket on the wall from where the Home UPS System input has been taken Care must be taken to ensure that the ON switch of the HOME UPS SYSTEM has been switched off so that the battery does not discharge To bypass the Home UPS System follow these steps 1 Removes Input Plug from the wall socket 2 Remove output Plug from HOME UPS SYSTEMS S output socket 3 Insert output plug into the wall socket ilicon ower Systems TECHNICAL SPECIFICATIONS INPUT VOLTAGE WINDOW Mains A C Low Cut 105 5V Mains A C Low Cut Recovery 120 5 V Mains A C High Cut 285 5V Mains A C High Cut Recovery 275 5V OUTPUT PARAMETERS Same as input 45Hz 55Hz 90 0Hz 0 1Hz 220V 200V 10V Mains Output Frequency Output Frequency on Inverter Output Voltage with Full Load Waveform Sine Wave Overload Above 110 Short Circuit Protection gt 250 Load Few msec BATTERY CHARGING SMPS based charger with automatic Power Factor Correction 9 0 1 0 Amp 13 9V 0 2V per battery Maximum Charging Current Limit Charging Boost Voltage Charging Float Voltage 13 6V 0 2V per battery 10 0V 0 2V per battery 120AH 180AH Note Specifications subject to change without prior notice B
3. and the output is from Home UPS Battery Backup 3 BATT CHARGING CHARGED This graphical symbol LED shows that the mains line is coming and side by side the charging of batteries is also taking place This graphical symbol glows intermittently Blinking during charging and glows continuously when battery is charged Cm om silicon Zower Systems Silicon ower Systems BACK PANEL KNOWING YOUR HOME UPS BACK PANEL ee The Home UPS has two battery wires Positive and Negative BATT LOW This graphical symbol LED when glows indicates that coming out from the rear side a Fuse Holder an output socket the battery voltage has gone down to the lower limit during and an input mains cable Connect the two battery wires to the discharge After this indication Home UPS will shut down terminals of the battery the red colored to the positive terminal and automatically after few minutes During this the buzzer gives a black colored to the negative terminal The three core input cable continuous beep provided from the UPS is used to connect the Home UPS to the incoming AC Mains Ensure that incoming AC Mains is proper in all OVERLOAD SHORT CIRCUIT This graphic symbol LED when the ways with good earthing After this the output is connected glows indicates that either short circuit has occurred or there is through the output socket at the rear of the Home U
4. PS Overload on the Home UPS The Home UPS resets itself automatically and makes 8 attempts in case overload and 4 Rear View attempts in case of short circuit to turn on again if the overload or short circuit continues even after these attempts it turns off permanently and will turn on only after ON OFF power active switch is turned OFF and then turned ON In the event of unsuccessful attempts it automatically shuts down During overload or short circuit graphical symbol LED lights up and the buzzer gives beep The beep is intermittent in case of overload and short circuit If there is short circuit at the output the Home UPS will turn off permanently after a few attempts It can be reset by removing short circuit and then switching off and on the power active switch 6 D silicon ower Systems ilicon ower Systems OO Oo WW NN Before proceeding further kindly go through the safety instructions carefully General Precautions di SAFETY INSTRUCTIONS MAINS INPUT Wire OUTPUT Socket Fuse Holder Battery Positive Battery Negative FAN IMPORTANT SAFETY INSTRUCTIONS Before using the Home UPS read all instructions and cautionary markings on the Home UPS the Batteries all appropriate section of this instruction manual Do not expose Home UPS to rain liquids of any type The Home UPS is designed for interiors only Do not disassemble t
5. all times By SILICON POWER SYSTEMS BANGALORE 2 Icon ower Systems CONTENTS SALIENT FEATURES KNOWING YOUR HOME UPS FRONT PANEL BACK PANEL IMPORTANT SAFETY INSTRUCTIONS SPECIAL NOTICES TROUBLE SHOOTING TECHNICAL SPECIFICATIONS BYPASSING THE HOME UPS WARRANTY CARD D ilicon Fower Systems ilicon Fower Systems KNOWING YOUR HOME UPS SALIENT FEATURES Now lets begin the journey to explore various aspect of your Silicon Pure Sine Wave Home UPS Welcome aboard Silicon s Home UPS is a truly futuristic concept It works as an offline Stand by UPS and switches over from mains to backup mode or vice versa It ensures continuous supply of power from the battery bank whenever mains supply from utility power is not available amp Pure Sine Wave output to run all the appliances FRONT VIEW ou are D Smart Overload Sense and Short Circuit Protection gt Automatic Low Battery Cutout MAINSON AN sor Ounce Dan De gt Smart SMPS based fast battery charger with automatic On the front panel of the Home UPS there is one ON OFF power active power factor correction peak power output 300 switch and a graphic symbol panel for indications s Wsernlendiy Graphic display Je Wa AI Ke symbol LED is lit when the incoming 2 INV ON This graphical symbol LED is lit when the incoming mains is not available
6. attery Lower Voltage Limit Recommended Battery Capacity Number of Batteries ilicon ower Systems TECHNICAL SPECIFICATIONS ilicon ower Systems WARRANTY CARD MODEL HU600SW HU800SW HU1000SW HU1400SW CAPACITY 600VA 12V 800VA 12V 1000VA 12V 1400VA 24V TECHNOLOGY Micro controller based state of the art technology using MOSFETs SMPS based charger ENVIRONMENT Storage Temp Operating Temp Humidity 0 90 Non Condensing TERMS AND CONDITIONS OF WARRANTY Silicon Power Systems hereby warrants to the original purchaser against any manufacturing defects arising through faulty workmanship and defective materials Except LED s switches and external body for a period of 2 years from the date of original purchase Your sale receipt is the proof of purchase for the product and the warranty period commences from that date The said warranty shall be provided against the presentation of the sale receipt The replaced defective parts components shall be the property of Silicon Power Systems The above warranty shall not be valid O C2 Sl SP Ci ss o If the installation of the Home UPS is improper if not undertaken by Company Engineer or its representative If physical damage has been done at the user s end If the Home UPS has been opened by an un authorized personnel If water any other liquid is found inside the inverter If dama
7. g with a battery A battery can produce a short circuit current high enough to weld a ring or causing severe burns SAFETY INSTRUCTIONS ilicon ilicon ower Systems ower Systems SPECIAL NOTICES TROUBLE SHOOTING IMPORTANT PRECAUTIONS The output side of the Home UPS AC wiring should never be connected to a generator or incoming Symptoms Rectifications utility power This condition is far worse than a short circuit If the a ae ee Main Power is coming NI unit survives this condition it will shut down until correction is Home UPS shows Reduce the load and replace the glass fuse of specified made mains fuse blown on rating given at the rear side of the Home UPS its display panel Note Never disconnect the battery cables while the Home UPS is delivering power or battery charger is operating The Power Active TET Home UPS by power active switch Allow the battery to charge Switch has no effect on the charger it turns off only the power DITO WEE ang Pak d before running the Home UPS on battery again output during backup mode To disconnect the batteries for service a la a turn off the power switch Check if overload short circuit LED is glowing b disconnect all AC power Reduce load and reset the Home UPS by Power Active switch c disconnect all the batteries cables Home UPS does not operate Check the battery connections SPECIAL NOTICES Do no
8. ge caused due to fuse replacement of improper rating For any defects arising in the Home UPS due to battery related failure defects If modification of the product Change in factory settings is done by an un authorized personnel If the product is used improperly and unprofessionally If defects arising in company s opinion by reasons of accident abuse misuse neglect improper installation or through fire flood or other act of God and any other natural calamities The problem of fuse blown will not be included in the warranty of the product The service given for the same will be a paid service The Company will not be responsible for any delay in servicing due to non availability of any components or due to reasons beyond the control of the company The company is in no way are will be held liable for any loss or injury or damage caused to life or property or death and disability caused to any form of life for any reason whatsoever The company expressly denies the right of any person to incur or assure for it any other liability or obligation in connection with the sale of Home UPS Claims if any to this warranty shall be made only before the courts having jurisdiction in Bangalore WARRANTY CARD DEALER STAMP
9. he Home UPS take it to a Silicon Engineering Service Centre when service or repair is required Opening by unqualified personnel entails electric shock or fire hazard To reduce risk of electric shock disconnect all wiring before cleaning Warning Risk of Explosive gases WORKING IN THE VICINITY OF ALEAD ACID BATTERY MAY BE DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL OPERATION Provide ventilation to outdoors from the battery compartment The battery enclosures should be designed to prevent accumulation and concentration of hydrogen gas in pockets at the top of the compartment Vent the battery compartment from the highest point A sloped lid can also be used to direct the flow to the vent opening location To reduce the risk of battery explosion follow all the Instruction of batteries supplier or any equipment you intend to use in the vicinity of batteries Do not cover your Home UPS with any cover or cloth Do not install this Home UPS on or near flammable materials plywood Chemicals gasoline etc Do not install this home UPS near extremely humid places or where there is water it is designed for use in interiors only Be extra cautious when working with metal tools on and around batteries It could short circuit the batteries or other electrical parts producing a spark that could cause explosion Remove conductive jewelry such as rings bracelets necklaces and watches when workin
10. t switch on the heavy load TV Home UPS trips Check if low battery LED is glowing switch OFF the Refrigerators Motor Cooler etc when Home UPS is running on frequently at Reduce the overload and restart the Home UPS through the battery backup and is in UPS mode This may cause rebooting of backup mode power active switch your computer BS Avoid connecting the stabilizer between utility power and Home UPS The AVR of stabilizer may cause your Symptoms computer to reboot i BS We recommend that you have point to point wiring of the Low Battery ee eanet e e SERIE 5 Check water level of the battery periodically amp ensure battery terminals are cleaned and properly fastened amp System shut down Output of Home UPS Check the proper AC input Lubricated with petroleum jelly after 20 sec no display S wired back to its own input and output wiring ed AC output Measuring with the wrong voltmeter h taq GROUNDING INSTRUCTIONS This Home UPS must be ee fe Weak batteries or battery cables too long e er to cable and battery connected to a grounded permanent wiring system Sa a Home UPS oe IS NO Output cose or corroded battery connections Check and clean all connections yilicon ower Systems BYPASSING THE HOME UPS SYSTEM KEB INPUT Sls Wall Socket lhe 3 core INPUT Plug INPUT mi BAT 5 4 Output Plug UPS Back Panel Note

Download Pdf Manuals

image

Related Search

Related Contents

YMC-Triart C18/C8 1.9 μm  AT91SAM7SE-EK Evaluation Board User Guide  Installation and Wire connection manual Manuel d`installation et de  Samsung P1000 User Manual  FREELANDER    prompto  Dyno Technology 9.06 4GB Black tablet  334161A, SaniForce Piston Pump Elevator Packages  Mode d`emploi Balena 6000 43  