Home

SLIDING GATE OPENER CONTROL BOARD SL1800 USER MANUAL

image

Contents

1. 4 5 Motor running time adjustment Motor running time is adjustable from 5s to 100s Press S4 button to close the door when the door opens at the openning limit position and the door stops when meets closing limit It is the closing running time of motor Press S4 button to open the door when the door is closed at the closing limit position and the door stops when meets openning limit It is the openning running time of motor It is only needed to select one process between these two DL3 keeps blinking during the process and will be off after motor stops at the limit position Running time adjustment is finished Note Cannot set up running time when Deadman model Press the time set up button continue pressing for 8s until time set up light turns off Release the button LED will be on about 1s and then off the time deleting process is successful 4 6 Soft stop speed adjustment Adjust potentiometer PT3 SoftSpeed to adjust the speed of soft stop Speed goes down when adjust it CCW Soft stop speed adjustment only work when time of soft stop is effective and PT3 is adjusted to max when delivery 4 7 Flash lamp It keeps lighting when open or close the door After door is fully closed it will keep lighting for 90 seconds 4 8 DIP switch S5 logic function DIP1 DIP2 Auto close time DIP3 DIP4 Soft stop time DIP5 Soft start function OFF OFF No auto close OFF OFF No soft stop ON Turn on soft start function OFF ON 5S OFF ON is OFF Disable
2. SLIDING GATE OPENER CONTROL BOARD SL1800 USER MANUAL I Safety Instruction 1 1 For security please read instructions carefully before initial operation making sure that the power is off before connectio Ret 1 2 Please clear the memory before initial operation Erasing ALL learned memorized Transmitter 1 3 Do not learn the remote control when motor is operating in order to avoid mis operation 1 3 The received signal may be interfered by other communication devices e g the wireless control system with the same frequency range 1 4 It is used only for the manual remote control and wireless control equipment system which must not endanger life or property during running failure or its security risks have been eliminated 1 5 It should be applied in dry indoor place or in the electric appliance place II Technical Index 2 1 Working voltage 220VAC 110VAC 50Hz 60Hz 2 2 Temperature range 20 C to 60 C 2 3 Loading capacity 1 HP 220VAC 0 5 HP 110VAC 2 4 Built in fuse electric circuit 0 5A Motor 10A Please exchange appropriate fuse accoding to loading capacity 2 5 Time of soft start 1S soft stop 18 2S 3S are optional 2 6 Running time Adjustable from 5s to 100s S4 is to set up 2 7 Frequency 433 92MHz 2 8 Transmitter stored 30PCS 2 9 Output voltage AC24V 2 11 Output with flash lamp AC220V AC110V 2 12 External switch open stop close in a loop 2 13 External limit DIP8 to select NO an
3. VAC 433 92Mhz
4. d NC 2 14 External infrared NC contact 2 15 Auto close time is adjustable 5S 10S 30S are optional by using DIP1 DIP2 2 16 Soft start function is optional by DIPS 2 17 Installation at left or right side is optional by DIP6 2 18 Single three button control is optional by DIP7 2 10 Output with electric lock normally closed contact 2 19 Size 155 77 38mm III Wire connection 0 5A fuse 5 eae Pe om aan gt TO Q o Learning light External antenna idl e Learning button H i I an g Time set up light Dea ma Power light o u 010A fuse A a o 124V lt Time set up button Lr Soft stop speed adjusment SLISXXVI potentiometer a aie M A AutoClase D J Sof Speed g 4 dab oj je D pa sin le loo oe DIP switch S5 wo e Io Su ruga D H SFE SLOT a i F F D i Right Instoul D gt j LKey Renster a F i s i F r D Sf NC Limit Switch D 2 D T 6 an DP 2 z Bc 2 al F N L 3 0 O a 2 2 0 A k a L Ta External control Limit Photocel 22V AG Lock Lamp switch switch output output output Motor AC input IV Set up 4 1 Learning and erasing transmitters by receiver Press the learning button S3 in the board LED DL2 is on enters into the learning process Press the same button twice LED blinks for several times then off The learning process is successful Press the learning button continue pressing for 8s until LED turn
5. s off Release learning button LED will be on about 1s and then off the erasing process is successful Ignore this step if transmitter already matches the opener before delivery The board can learn 30pcs transmitters max self learning function Use the transmitter that already has been learned as old transmitter press button 1 and button 2 at the same time and then press button 2 to let it enters into the learning process Press the same button on the new transmitter twice The learning process done In this way new transmitter can be learned without pressing the learning button on the control board m 4 3 Opening closing limit adjustment Remote control the door or move the door manually adjust the position of limit device to make sure the door would touch the limit switch when open or close the door LED LD6 DL5 in the controller will be off when limit device touches limit switch Limit switch is NC 4 4 External infrared switch Photocell connector connects the NC contact of photocell switch DL4 LED turn on after the connection And DL4 LED turn off when blocking out the transmit or receive signal of photocell artificially Infrared sensor doesn t react when door openning and the door will reverse to limit point if photocell signal disconnect when door closing If no need of using photocell protection make the connector of photocell short circuit with terminated line the connector is short circuit when leave factory
6. soft start funtion ON OFF 10S ON OFF 20 ON ON 20S ON ON 35 DIP6 tight left side installation DJP7 DIPS ON ON or OFF can change the ON Single button control ON External limit NC switch current operating OFF direction of motor OFF Three button control OFF External limit NO switch V Operation Instruction 5 1 Three button control process DIP 7 at OFF position STOP Press transmitter button 1 o e a Press transmitter button 3 Press transmitter Photocell protection Max running Press transmitte r button 2 running time button 2 time eel 5 2 Single button control process DIP 7 at ON position Description Single button control press open press stop press stop Only the learned button is effective in the transmitter original button is not effective any more when a new button has been learned in the same transmitter For example button 1 was learned firstly button 2 or 3 has been learned of the same transmitter afterwards then button 1 was not effective any more Press transmitte r button 1 running time VI Notes 6 1 Photocell protection switch shall be examined regularly Photocell protection Press transmitter button 1 running time VII Model difference Transmitter stored pcs SL1800 220VAC 433 92Mhz SL1820 LLOVAC Oo 0 433 92Mhz 921 SL1801 220VAC 433 92Mhz 30 1921 SL1821 LLO