Home

www.pce-industrial-needs.com Manual Thickness meters PCE

image

Contents

1. 3 Press the Sensor 3 7 onto the material surface to measure on the premise that the material code selected is right Be sure that coupling is well and the symbol e is on The reading on display is the measurement value 6 4 The reading is held till a new measurement value is coming The last value is held on the display till the power is off 6 5 2 modes to turn off the power Manual off at any time by pressing the power key or Auto power off after about 1 minutes from last key operation 7 MEASURING BY VELOCITY SETTING 7 1 Press the VEL key 3 13 and the display shows the velocity set last time 7 2 How to measure its thickness by the velocity known The velocity can be changed by pressing the plus key or minus key to the value of known velocity the increment is 10m s every time When pressing the plus or minus key And the increment is 100 ms if depressing the key formore than about 4 seconds 7 3 Drop a little oil into the material to measure and press the Sensor 3 7 onto the surface The reading on the display is the thickness The reading on the display is the thickness if coupling well So if we have known the velocity of a certain material it is easy to measure the thickness by 7 2 info tursdaletechnicalservices co uk 7 4 How to measure the thickness by a sample of known thickness Just get a sample of known thickness Then repeat 7 2 and 7 3 till the measurement value is totally same as the known thickness In suc
2. h a case the set value is the velocity of the material to measure by which you can measure any unknown thickness of same material 7 5 To browse the velocity if only press the VEL key 3 13 To quit browsing if only press the VEL key 3 13 again or wait till the meter automatically show 0 7 6 By use of velocity measurement it is easy to measure the thickness of any hard materials 8 BATTERY REPLACEMENT 8 1 When the battery symbol appears on the display it is time to replace the batteries 8 2 Slide the Battery Cover away from the instrument and remove the batteries 8 3 Install batteries paying careful attention to polarity In this direction will find a vision of the measurement technique http www industrial needs com measuring instruments htm NOTE This instrument doesn t have ATEX protection so it should not be used in potentially explosive atmospheres powder flammable gases
3. lways keep this manual within easy reach info tursdaletechnicalservices co uk 1 FEATURES e Used the exclusive micro computer LSI circuit and crystal time base to offer high accuracy measurement e With high power emission and broad band of receiving sensitivity the gauge can match probe of different frequencies That makes it easy to measure the rough surface even cast iron It is widely used in almost all kinds of industries e Applicable to measure the thickness of many materials e g Steel Cast iron Aluminium Red copper Brass Zinc Quartz glass Polyethylene PVC Gray cast iron Nodular cast iron e Automatic power off to conserve power e Can communicate with PCE computer for statistics an printing by the opcitonal cable and the software for RS 232C interface 2 SPECIFICATIONS Display 4 digits 10 mm LCD Range 1 0 200mm 45 steel Resolution 0 1mm 0 00 linch Accuracy 0 5 n 0 1 Sound velocity 500 9000 m s Power supply 4x1 5v AAA UM 4 battery Operating condition Temp 0 50 C Humidity lt 80 Size 120x62x30mm 4 7 x 2 4 x 1 2 inch Weight about 164g not including batteries Accessory Carrying Case 1 pc Operation manual 1 pc Ultrasonic sensor 1 pc Optional accessories Cable amp software for RS 232C info tursdaletechnicalservices co uk 3 FRONT PANEL DESCRIPTIONS 3 6 3 5 3 3 3 10 3 1 Sensor plug 3 2 Display 3 3 mm inch key 3 4 Po
4. splaying cd11 or pressing the Minus key 3 9 when displaying cd01 The 4 digit number is last sound velocity to define by the user By selecting this velocity you could measure the thickness of the same material as last 4 5 It is unnecessary to select the material code once the material code is confirmed automatically stored to the memory of the meter unless the material to measure is diferrent from that before 4 6 To browse the material code selected if only press the Select key 3 5 again or wait till the code automatically change to 0 after several seconds or the meter will automatically return to measurement state if measuring info tursdaletechnicalservices co uk 5 CALIBRATION 5 1 Drop a little oil on the 5 mm standard block 3 12 5 2 Press the Calibration key 3 8 the CAL be shown on the Display CAL is the short for calibration 5 3 Press the sensor 3 7 on the standard block The coupling symbol is on if coupling well 5mm or 0 197 inch and CAL will be shown on the Display in turn When steady Press CAL key 3 8 to confirm and then the unit return to the state of measurement 5 4 The calibration result will be auto saved to the unit once confirmation It is unnecessary to calibrate often unless you suspect the accuracy measurement 6 MEASURING PROCEDURE 6 1 Press the power key 3 4 to turn on the unit 6 2 Press the mm inch key 3 3 to select the right measurement unit 6
5. wer key 3 5 Material selection key 3 6 Plus key 3 7 Ultrasonic sensor 3 8 Calibration key 3 9 Minus key 3 10 Battery Compartment Cover 3 11 Coupling indicator 3 12 Standard Block 3 13 Velocity key 3 14 RS 232C interface 4 MATERIAL SELECTION 4 1 Press the power key 3 4 to turn on the unit 4 2 Press the Material Selection key 3 5 and the display 3 2 will show the code cdxx or xxxx cd is the abbreviation for code and xx is one number among 01 11 xxxx is a 4 4 info tursdaletechnicalservices co uk digit number which is the sound velocity of material defined by the user The cdxx material relationship is as follow No CODE Material 1 cd01 Steel 2 cd02 Cast iron 3 cd03 Aluminium 4 cd04 Rep copper 5 cd05 Brass 6 cd06 Zinc 7 cd07 Quartz glass 8 cd08 Polyethylene 9 cd09 PVC 10 cd10 Gray cast iron 11 cd11 Nodular cast iron 12 cd12 Sound velocity 4 3 Press the Plus key 3 6 or Minus key 3 9 to select the material code to measure and press the Material Selection key to confirm The display will show O If you select a material code but do no confirm the selection the code will automatically change to O after several seconds In such case the meter will still reserve the material code before exiting 4 4 A 4 digit number will be shown on the Display if pressing the plus key 3 6 when di
6. www pce industrial needs com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co Durham DH6 5PG United Kingdom Phone 44 0 191 377 3398 Fax 44 0 191 377 3357 info tursdaletechnicalservices co uk http www industrial needs com Manual Thickness meters PCE TG 50 info tursdaletechnicalservices co uk Man al Thickness WiC UGS osiiisasdnirninisisinaini ininde iiid aai iai ia ioiii ibadiidid 1 POCE a eseehicic e E EE E Ee E E aS 1 I FREATURES emr T E S 3 2 SPECIFICATION ic eee en aiaa aaa aaa a a a a a a AR EEROR 3 3 FRONT PANEL DESCRIPTIONS occ cc cc cccccccccc cece eeseeceeeceeeeseueeeueeeseeseueceueeesaeesaneeueeeaeees 4 Be IVA TE ale SELEG TION sigur de dees ciaeiela tas eet wi ecieedd Seda Sows a eee 4 5 CALIBRA TION ororena aes aeae E EAEn AEE A EEEO aa EE AEAEE E TOR an ADE EEES 6 6 MEASURING PROCEDURE eccentrics eh cece ridinde deiei edea E aaa i a EE E Aa 6 7 MEASURING BY VELOCITY SETTING wocccccccscccccccceccctccccscccsecessccdadedecsedacesadedndeandadadcandeaeens 6 8 BATTERY REPLACEMENT vocedeeetsceretteectoccseecehic veceesrececceiseeceeas ceeecuaczeee ress ceeseeeceveceeserenunce 7 This thickness meter is small in size light in weight easy to carry Although complex and advanced it is convenient to use and operate Its ruggedness will allow many year of use if proper operating techniques are followed Please read the following instructions carefully and a

Download Pdf Manuals

image

Related Search

Related Contents

Keating Of Chicago 31920 User's Manual  IG550 Integrated Gateway  Kingston Technology ValueRAM 32GB DDR3-1333  Wireless Audio - Soundbar  hi-Energy - DbWeb  documento adjunto  LAVE-VAISSELLE  Operating instructions Funkwerk TR 200 aw/ bw  

Copyright © All rights reserved.
Failed to retrieve file