Home

Datasheet

image

Contents

1. mm in Height 229 9 0 Width 439 17 3 Depth 147 5 8 kg Ib Net 5 11 Shipping 10 7 23 6 5U 2 in 51 mm required on left side and rear of instrument EMC environment and safety Temperature Operating Nonoperating Humidity Operating Nonoperating Altitude Operating Nonoperating Regulatory Electromagnetic compatibility Safety 0 C to 50 C 32 F to 122 F 20 C to 60 C 4 F to 140 F High 40 C to 50 C 10 to 60 relative humidity Low 0 C to 40 C 10 to 90 relative humidity High 40 C to 60 C 5 to 60 relative humidity Low 0 C to 40 C 5 to 90 relative humidity 3 000 meters 9 843 feet 9 144 meters 30 000 feet EC Council Directive 2004 108 EC UL61010 1 2004 CAN CSA C22 2 No 61010 1 2004 Low Voltage Directive 2006 95 EC and EN61010 1 2001 IEC 61010 1 2001 ANSI 61010 1 2004 ISA 82 02 01 Ordering information MSO DPO4000B family DPO4014B DP04034B DP04054B DPO4102B L DP04102B 100 MHz 2 5 2 5 2 5 GS s on 1 2 4 channels 20M record length 4 channel digital phosphor oscilloscope 350 MHz 2 5 2 5 2 5 GS s on 1 2 4 channels 20M record length 4 channel digital phosphor oscilloscope 500 MHz 2 5 2 5 2 5 GS s on 1 2 4 channels 20M record length 4 channel digital phosphor oscilloscope 1 GHz 5 2 5 GS s on 1 2 channels 5M record length 2 channel digital phosphor oscilloscope 1 GHz 5 5 GS s on 1 2 channels 20M record length 2 cha
2. Mixed Signal Oscilloscopes MSO4000B DPO4000B Series Datasheet Key features Wave Inspector controls provide easy navigation and automated search of waveform data 41 automated measurements and FFT analysis for simplified waveform analysis 16 digital channels MSO series Mixed signal design and analysis MSO series Automated triggering decode and search on parallel buses Per channel threshold settings Multichannel setup and hold triggering MagniVu High speed acquisition provides 60 6 ps fine timing resolution on digital channels Optional serial triggering and analysis automated serial triggering With the MSO DPO4000B Mixed Signal Oscilloscope Series you can decode and search options for I2C SPI USB Ethernet CAN LIN analyze up to 20 analog and digital signals with a single instrument to FlexRay RS 232 422 485 UART MIL STD 1553 and 2S LJ RJ TDM quickly find and diagnose problems in complex designs Bandwidths up to oe 1 GHz and up to 5X oversampling on all channels ensure you have the TekVPI probe interlace supports active differential and current performance you need to see fast changing signal details To capture long probes for automatic scaling and units windows of signal activity while maintaining fine timing resolution the MSO 10 4 in 264 mm bright XGA color display DPO4000B Series offers deep record length of up to 20M points standard on all channels And with Wa
3. 50 Hz Australia power plug 240 V 50 Hz Switzerland power plug 220 V 50 Hz Japan power plug 100 V 110 120 V 60 Hz China power plug 50 Hz India power plug 50 Hz Brazil power plug 60 Hz No power cord English manual French manual Italian manual German manual Spanish manual Japanese manual Portuguese manual Simplified Chinese manual Traditional Chinese manual Korean manual 8 USB high speed supported only on models with 1 GHz analog channel bandwidth 9 2350 MHz bandwidth models are recommended for mask testing on telecomm standards gt 55 Mb s 1 GHz bandwidth models are recommended for mask testing on high speed HS USB 22 Wwww tektronix com Mixed Signal Oscilloscopes MSO4000B DPO4000B Series Opt L10 Russian manual Opt L99 No manual Language options include translated front panel overlay for the selected language s Service options Opt C3 Calibration Service 3 Years Opt C5 Calibration Service 5 Years Opt D1 Calibration Data Report Opt D3 Calibration Data Report 3 Years with Opt C3 Opt D5 Calibration Data Report 5 Years with Opt C5 Opt R5 Repair Service 5 Years including warranty Opt SILV600 Standard warranty extended to 5 years Probes and accessories are not covered by the oscilloscope warranty and service offerings Refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms Recommended accessories Probes Tektronix
4. and actions upon violations test failure and test complete Whether specifying a mask from a known good signal or from a custom or standard mask conducting pass fail tests in search of waveform anomalies such as glitches has never been easier 8 www tektronix com Show Results Show Results Limit Mask Test Results Current Totals Test Statu Failed Total yee e E 39 669k Violatio 1 Total Tests Failed Tests Elapsed Time Total Hits Limit Mas Test On Limit Test Limit Test showing a mask created from a golden waveform and compared against a live signal Results showing statistical information about the test are displayed Video design and development Many video engineers have remained loyal to analog oscilloscopes believing the intensity gradations on an analog display are the only way to see certain video waveform details The fast waveform capture rate coupled with its intensity graded view of the signal provides the same information rich display as an analog oscilloscope but with much more detail and all the benefits of digital scopes Standard features such as IRE and mV graticules holdoff by fields video polarity and an Autoset smart enough to detect video signals make these the easiest to use oscilloscopes on the market for video applications And with high bandwidth and four analog inputs the oscilloscope provides ample performance for analog and digital video use The video functionality is further ex
5. 5 V div 100 V 5 V 5 05 V div to 10 V div 50 V NA www tektronix com 11 Datasheet Vertical system digital channels Input channels 16 digital D15 to DO Thresholds Per channel thresholds Threshold selections TTL CMOS ECL PECL User defined User defined threshold range 40 V Threshold accuracy 100 mV 3 of threshold setting Maximum input voltage 42 Voeak Input dynamic range 30 Vp p 200 MHz 10 Vp p gt 200 MHz Minimum voltage swing 400 mV Probe loading 100 KQ in parallel with 3 pF Vertical resolution 1 bit Horizontal system analog channels Time base range 1 GHz models 400 ps to 1000 s lt 500 MHz models 1 ns to 1000 s Time base delay time range 10 divisions to 5000 s Channel to channel deskew range 125ns Time base accuracy 5 ppm over any 21 ms interval Horizontal system digital channels Maximum sample rate Main 500 MS s 2 ns resolution Maximum record length Main 20M points 5M points on L models Maximum sample rate MagniVu 16 5 GS s 60 6 ps resolution Maximum record length MagniVu 10k points centered around the trigger Minimum detectable pulse width 1 ns typical Channel to channel skew typical 200 ps Maximum input toggle rate 500 MHz Maximum frequency sine wave that can accurately be reproduced as a logic square wave Requires the use of a short ground extender on each channel This is the maximum frequency at the minimum swing amplitude Higher toggle rates can be achieved wi
6. USA 1 800 833 9200 European toll free number If not accessible call 41 52 675 3777 Updated 10 April 2013 For Further Information Tektronix maintains a comprehensive constantly expanding collection of application notes technical briefs and other resources to help engineers working on the cutting edge of technology Please visit www tektronix com Copyright Tektronix Inc All rights reserved Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specification and price LEX change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc All other trade names referenced are the service marks trademarks or registered trademarks of their respective companies n a 16 Apr 2013 3GW 20156 17 www tektronix com Tektronix S
7. You can set threshold values for each channel enabling support for up to 16 different logic families f 2 44V S ie Once a group is formed you can position all the channels contained in that group collectively This greatly reduces the normal setup time associated with positioning channels individually rc www tektronix com 5 Datasheet MagniVu high speed acquisition The main digital acquisition mode on the MSO4000B Series will capture up to 20M points at 500 MS s 2 ns resolution In addition to the main record the oscilloscope provides an ultra high resolution record called MagniVu which acquires 10 000 points at up to 16 5 GS s 60 6 ps resolution Both main and MagniVu waveforms are acquired on every trigger and can be switched between in the display at any time running or stopped MagniVu provides significantly finer timing resolution than comparable MSOs on the market instilling confidence when making critical timing measurements on digital waveforms Zoom Factor 20 X AL PSs ji 10k points J T varai Gee Timing Resolution 60 6ps _ The MagniVu high resolution record provides 60 6 ps timing resolution enabling you to make critical timing measurements on your digital waveforms P6616 MSO probe This unique probe design offers two eight channel pods Each channel ends with a probe tip featuring a recessed ground for simplified connection to the device under test The coax
8. blue Jlixed Signal Oscilloscopes MSO4000B DPO4000B Ww ON eries The multiple transition detection hardware shows you a white edge on the display when the system detects multiple transitions White edges indicate that more information is available by zooming in or acquiring at faster sampling rates In most cases zooming in will reveal the pulse that was not viewable with the previous settings If the white edge is still present after zooming in as far as possible this indicates that increasing the sample rate on the next acquisition will reveal higher frequency information than the previous settings could acquire Stop he White edges indicate additional information is available by zooming in As shown here zooming in on the white edge reveals a hidden glitch You can group digital waveforms and enter waveform labels by using a USB keyboard By simply placing digital waveforms next to each other they form a group f Digital Channel Vertical Position 3 44 div Select 1 60 V T pisov Apply Preset 1 40 V Lime EE e e e 1 40 V 1 60 1 80 V 2 00 V 2 20 V 2 40 V y BEBE REREE ez various 250MS s__ 10k points sat Timinda Resoluti D15 D0 Edit MagniVu On Off Thresholds Labels On Off With color coded digital waveform display groups are created by simply placing digital channels together on the screen allowing digital channels to be moved as a group
9. offers over 100 different probes to meet your application needs For a comprehensive listing of available probes please visit www tektronix com probes TPP0500 500 MHz 10X TekVPI passive voltage probe with 3 9 pF input capacitance TPP0502 500 MHz 2X TekVPI passive voltage probe with 12 7 pF input capacitance TPP0850 2 5 kV 800 MHz 50X TekVPI passive high voltage probe TPP1000 1 GHz 10X TekVPI passive voltage probe with 3 9 pF input capacitance TAP1500 1 5 GHz TekVPI active single ended voltage probe TCP0030 120 MHz TekVPI 30 Ampere AC DC current probe TCP0150 20 MHz TekVPI 150 Ampere AC DC current probe TDP0500 500 MHz TekVPI differential voltage probe with 42 V differential input voltage TDP1000 1 GHz TekVPI differential voltage probe with 42 V differential input voltage TDP1500 1 5 GHz TekVPI differential voltage probe with 8 5 V differential input voltage THDP0200 1 5 kV 200 MHz TekVPI high voltage differential probe THDP0100 6 kV 100 MHz TekVPI high voltage differential probe TMDP0200 750 V 200 MHz TekVPI high voltage differential probe P5100A 2 5 kV 500 MHz 100X high voltage passive probe P5200A 1 3 kV 50 MHz high voltage differential probe www tektronix com 23 Datasheet Accessories 077 0512 xx Service manual English only TPA BNC TekVPI to TekProbe BNC adapter TEK DPG TekVPI Deskew pulse generator signal source 067 1686 xx Power measurement deskew and calibration fixture SIGEXPTE N
10. on the first channel of each pod is colored blue making it easy to identify The common ground uses an automotive style connector making it easy to create custom grounds for connecting to the device under test When connecting to square pins the P6616 has an adapter that attaches to the probe head extending the probe ground flush with the probe tip so you can attach to a header The P6616 offers outstanding electrical characteristics having only 3 pF of capacitive loading a 100 kQ input resistance and is capable of acquiring toggle rates gt 500 MHz and pulses as short as 1 ns in duration 6 www tektronix com The P6616 MSO probe offers two eight channel pods to simplify connecting to your device Serial triggering and analysis optional On a serial bus a single signal often includes address control data and clock information This can make isolating events of interest difficult Automatic trigger decode and search on bus events and conditions gives you a robust set of tools for debugging serial buses aT HD ES s H ME Ao Rn a aa n e AA a AN pA t O A AAA i a A k A A a LLL a h A a a a a D ad a a A EL LE Token Address Packet Sync H Out HAd 2H 2H 01 Sync H Datal 20 Z 1 00us 2 50GS s_ EN LIIM points L J D15 Do J gt Timing Resolution 2 00ns__ Token Packet Source Bus f Trigger On Token Type USB Token Packet Triggering on a specific OUT Token packet on a USB full sp
11. the oscilloscope www tektronix com 9 Datasheet Extended analysis Exporting data and measurements is as simple as connecting a USB cable from the oscilloscope to your PC Key software applications NI LabVIEW SignalExpress Tektronix Edition LE OpenChoice Desktop and Microsoft Excel and Word toolbars are included standard with each oscilloscope to enable fast and easy direct communication with your Windows PC NI LabVIEW SignalExpress Tektronix Edition LE enables you to instantly acquire generate analyze compare import and save measurement data and signals using an intuitive drag and drop user interface that does not require any programming The optional Professional Version offers over 200 built in functions that provide additional signal processing advanced analysis sweeping limit testing and user defined step capabilities For simple tasks the included OpenChoice Desktop enables fast and easy communication between the oscilloscope and your PC through USB or LAN for transferring settings waveforms and screen images p m Get amp Send Settings Preferences Screen Waveform Capture 227 07 15I DI s KOTT OLUK Select Instrument E MS04104B Select Channels KA Get Data Save As ral ess aS MS04104B Crosstalk on data lines Modify Note Tektronix OpenChoice Desktop software enables seamless connection between the oscilloscope and your PC 10 www tektronix com The MSO DPO
12. 00 events Pulse Width Trigger on width of positive or negative pulses that are gt lt or inside outside a specified period of time Timeout Trigger on an event which remains high low or either for a specified time period 4 ns to 8 s Runt Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again Logic Trigger when any logical pattern of channels goes false or stays true for specified period of time Any input can be used as a clock to look for the pattern on a clock edge Pattern AND OR NAND NOR specified for all input channels defined as High Low or Don t Care Setup and Hold Trigger on violations of both setup time and hold time between clock and data present on any of the analog and digital input channels Rise Fall Time Trigger on pulse edge rates that are faster or slower than specified Slope may be positive negative or either Video Trigger on all lines odd even or all fields on NTSC PAL and SECAM video signals Extended Video optional Trigger on 480p 60 576p 50 720p 30 720p 50 720p 60 8751 60 1080i 50 1080i 60 1080p 24 1080p 24sF 1080p 25 1080p 30 1080p 50 1080p 60 and custom bi level and tri level sync video standards I2C optional Trigger on Start Repeated Start Stop Missing ACK Address 7 or 10 bit Data or Address and Data on 2C buses up to 10 Mb s SPI optional Trigger on SS active Start of Frame MOSI MISO or MOSI and M
13. 3 5 NS 1ns 700 ps 350 ps 350 ps 350 ps 350 ps Sample rate 1 ch 2 0 GS s 2 0 GS s 2 5 GS s 5 GS s 5 GS s 5 GS s 5 GS s Sample rate 2 ch 2 0 GS s 2 0 GS s 2 5 GS s 2 0 GS s 5 GS s 5 GS s 5 GS s Sample rate 4 ch 2 0 GS s 2 0 GS s 2 0 GS s 2 5 GS s 5 GS s Record length 1 ch 20M 20M 20M 5M 20M 5M 20M Record length 2 ch 20M 20M 20M 5M 20M 5M 20M Record length 4 ch 20M 20M 20M 5M 20M Duration at highest sample rate 8 ms 8 ms 8 ms 1 ms 4ms 1 ms 4ms Digital channels MSO models add 16 digital channels to the corresponding DPO model Vertical system analog channels Hardware bandwidth limits 2350 MHz models 100 MHz models Input coupling Input impedance Input sensitivity range 1 MQ 50 Q Vertical resolution Maximum input voltage 1 MQ 50 Q DC gain accuracy Channel to channel isolation Offset range 20 MHz or 250 MHz 20 MHz AC DC 1 MQ 41 50 Q 1 1 mV div to 10 V div 1 mV div to 1 V div 8 bits 11 bits with Hi Res 300 Vays CAT II with peaks lt 425 V 5 VRMS with peaks lt 20 V 1 5 derated at 0 10 C above 30 C Any two channels at equal vertical scale 2100 1 at lt 100 MHz and 230 1 at gt 100 MHz up to the rated bandwidth Volts div setting Offset range 1 MQ input 50 Q 1 mV div to 50 mV div 1 V 1 V 50 5 mV div to 99 5 mV div 0 5 V 0 5 V 100 mV div to 500 mV div 10 V 10V 505 mV div to 995 mV div 5 V 5 V 1 V div to
14. 4000B Series can also be connected to your network using the LAN port The included LXI web interface provides information about the current configuration of your MSO DPO4000B Series oscilloscope including network configuration The LXI web interface also provides remote instrument control through the popular e Scope web based instrument control capability You can make changes to the network configuration control instrument settings save screen images and instrument data and save load instrument setups of your oscilloscope directly from the web interface through a password protected web page re th Wew Favotes Toos Ne WO Bevo taser PONN peeide0s20N 154 T D we ohm Ore Qie so Tektronix Pree E EE E o tome Welcome MS04104B Web Enabled User r tata A ee ee AE it tae ee _ ee a aaaga LXI 4 02 70 174 UE Clats Duara Sju rami 00 The LXI web interface provides access to network settings enables remote instrument control and is accessible from any standard web browser Specifications All specifications apply to all models unless noted otherwise Model overview Mixed Signal Oscilloscopes MSO4000B DPO4000B Series DPO4014B DPO4034B DPO4054B DPO4102B L DPO4102B DPO4104B L DPO4104B MS04014B MS04034B MS04054B MS04102B L MS04102B MSO4104B L MS0O4104B Analog channels 4 4 4 2 2 4 4 Bandwidth 100 MHz 350 MHz 500 MHz 1 GHz 1 GHz 1 GHz 1 GHz Rise time
15. ISO on SPI buses up to 50 0 Mb s RS 232 422 485 UART Trigger on Tx Start Bit Rx Start Bit Tx End of Packet Rx End of Packet Tx Data Rx Data Tx Parity Error and Rx Parity Error up optional to 10 Mb s www tektronix com 13 Datasheet USB Low speed optional USB Full speed optional USB High speed optional Trigger on Sync Active Start of Frame Reset Suspend Resume End of Packet Token Address Packet Data Packet Handshake Packet Special Packet Error Token packet trigger Any token type SOF OUT IN SETUP Address can be specified for Any Token OUT IN and SETUP token types Address can be further specified to trigger on lt lt gt 2 a particular value or inside or outside of a range Frame number can be specified for SOF token using binary hex unsigned decimal and don t care digits Data packet trigger Any data type DATAO DATA1 Data can be further specified to trigger on lt lt gt 2 a particular data value or inside or outside of a range Handshake packet trigger Any handshake type ACK NAK STALL Special packet trigger Any special type Reserved Error trigger PID Check CRC5 or CRC 16 Bit Stuffing Trigger on Sync Reset Suspend Resume End of Packet Token Address Packet Data Packet Handshake Packet Special Packet Error Token packet trigger Any token type SOF OUT IN SETUP Address can be specified for Any Token OUT IN and SETUP toke
16. T DPO4VID Instrument options USB Serial Triggering and Analysis Module Enables triggering on packet level content for low speed full speed and high speed USB serial buses Also enables analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information for low speed full speed and high speed USB serial buses 8 Signal Inputs Low speed and Full speed Any Ch1 Ch4 and any DO D15 on MSO models Low speed Full speed and High speed Any Ch1 Ch4 Math Ref1 Ref4 Recommended Probing Low speed and Full speed Single ended or differential High speed Differential Power Analysis Application Module Enables quick and accurate analysis of power quality switching loss harmonics safe operating area SOA modulation ripple and slew rate dl dt dV dt Limit and Mask Testing Application Module Enables testing against limit templates generated from golden waveforms and mask testing using custom or standard telecommunications or computer masks HDTV and Custom nonstandard Video Triggering Module Power cord and plug options Opt A0 Opt A1 Opt A2 Opt A3 Opt A5 Opt A6 Opt A10 Opt A11 Opt A12 Opt A99 Language options Opt LO Opt L1 Opt L2 Opt L3 Opt L4 Opt L5 Opt L6 Opt L7 Opt L8 Opt L9 North America power plug 115 V 60 Hz Universal Euro power plug 220 V 50 Hz United Kingdom power plug 240 V
17. The TPP Series passive voltage probes offer all the benefits of general purpose probes like high dynamic range flexible connection options and robust mechanical design while providing the performance of active probes In addition a low attenuation 2X version of the TPP probes is available for measuring low voltages Unlike other low attenuation passive probes the TPP0502 has high bandwidth 500 MHz as well as low capacitive loading 12 7 pF Mixed signal design and analysis MSO series The MSO models provide 16 digital channels which are tightly integrated into the oscilloscope s user interface This simplifies operation and makes it possible to solve mixed signal issues easily 11 20MH2_CLOCK Afton lahis joy para Ilo tabas ahai dan taha balan oe gt COUNT4 Ey COUNTS 3 collar COUNT fy COUNTO 0 CLOCK Parallel 5 00 V 5 00GS s Data 1M points D15 D0 Timing Resolution 2 00ns_ gt The MSO Series provides 16 integrated digital channels enabling you to view and analyze time correlated analog and digital signals Color coded digital waveform display This oscilloscope has redefined the way you view digital waveforms One common problem shared by both logic analyzers and mixed signal oscilloscopes is determining if data is a one or a zero when zoomed in far enough that the digital trace stays flat all the way across the display Color coded digital traces display ones in green and zeros in
18. analysis limit testing data logging and customizable reports DPO4000B Series Mixed Signal Oscilloscopes MSO4000B f 398 90ns i 403 60ns 3 74 V A4 7000Nns A120MY 3 62 V 1 00 V Value Mean Min Max Std Dev 10 0ns 5 00GS s s 160v 10k points Peak Peak 4 28V 4 39 4 24 4 64 103m T2 ENa EIEEE E NE 2 174 2 990 686 3m J Analyze Waveform histogram of a falling edge showing the distribution of edge position jitter over time Included are numeric measurements made on the waveform histogram data A comprehensive set of integrated analysis tools speeds verification of your design s performance Mixed domain analysis Working with RF signals Be sure to check out the MDO4000 Series the world s first Mixed Domain Oscilloscope Built on the MSO4000B oscilloscope platform the MDO4000 Series offers a built in spectrum analyzer up to 6 GHz This combination offers you the ability to capture time correlated analog digital and RF signals in a single instrument For more information on the MDO4000 Series please visit Wave Inspector navigation and search With long record lengths a single acquisition can include thousands of screens of waveform data Wave Inspector the industry s best tool for navigation and search enables you to find events of interest in seconds oon EN la apee no M Wave Inspector controls provide unprecedented efficiency in viewing naviga
19. ational Instruments LabVIEW Signal Express Tektronix Edition software full version FPGAView A MSO Support for Altera FPGAs TEK USB 488 GPIB to USB adapter ACD4000B Soft transit case HCTEK54 Hard transit case requires ACD4000B RMD5000 Rackmount kit Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar GPIB Product s complies with IEEE Standard 488 1 1987 RS 232 C and with Tektronix Standard Codes and Formats IEEE 488 ASEAN Australasia 65 6356 3900 Austria 00800 2255 4835 Balkans Israel South Africa and other ISE Countries 41 52 675 3777 Belgium 00800 2255 4835 Brazil 55 11 3759 7627 Canada 1 800 833 9200 Central East Europe and the Baltics 41 52 675 3777 Central Europe amp Greece 41 52 675 3777 Denmark 45 80 88 1401 Finland 41 52 675 3777 France 00800 2255 4835 Germany 00800 2255 4835 Hong Kong 400 820 5835 India 000 800 650 1835 Italy 00800 2255 4835 Japan 81 3 6714 3010 Luxembourg 41 52 675 3777 Mexico Central South America amp Caribbean 52 55 56 04 50 90 Middle East Asia and North Africa 41 52 675 3777 The Netherlands 00800 2255 4835 Norway 800 16098 People s Republic of China 400 820 5835 Poland 41 52 675 3777 Portugal 80 08 12370 Republic of Korea 001 800 8255 2835 Russia amp CIS 7 495 6647564 South Africa 41 52 675 3777 Spain 00800 2255 4835 Sweden 00800 2255 4835 Switzerland 00800 2255 4835 Taiwan 886 2 2722 9622 United Kingdom amp Ireland 00800 2255 4835
20. c array of values that can be measured Sources Channel 1 Channel 2 Channel 3 Channel 4 Ref 1 Ref 2 Ref 3 Ref 4 Math Types Vertical Horizontal Waveform Count Hits in Box Peak Hits Median Max Min Peak to Peak Mean Standard Deviation Sigma 1 Sigma 2 Sigma 3 Add subtract multiply and divide waveforms Integrate Differentiate FFT Spectral magnitude Set FFT Vertical Scale to Linear RMS or dBV RMS and FFT Window to Rectangular Hamming Hanning or Blackman Harris Define extensive algebraic expressions including waveforms reference waveforms math functions FFT Intg Diff Log Exp Sart Abs Sine Cosine Tangent Rad Deg scalars up to two user adjustable variables and results of parametric measurements Period Freq Delay Rise Fall PosWidth NegWidth BurstWidth Phase PosDutyCycle NegDutyCycle PosOverShoot NegOverShoot PeakPeak Amplitude RMS CycleRMS High Low Max Min Mean CycleMean Area CycleArea and trend plots e g Intg Ch1 Mean Ch1 x 1 414 x VAR Power measurements optional Vems Vcrest Factor Frequency lps Icrest Factor True Power Apparent Power Reactive Power Power Factor Phase Angle Ton To Conduction Total Ton To Conduction Total THD F THD R RMS measurements Graphical and table displays of harmonics Test to IEC61000 3 2 Class A and MIL STD 1399 Section 300A VRipple and lRipple Graphical display of Pulse Width Pulse Width Period Fre
21. ce SRQ Test status total waveforms number of violations violation rate total tests failed tests test failure rate elapsed time total hits for each mask segment A fully interactive measurement software environment optimized for your Tektronix oscilloscope enables you to instantly acquire generate analyze compare import and save measurement data and signals using an intuitive drag and drop user interface that does not require any programming Standard support for acquiring controlling viewing and exporting your live analog channel signal data is permanently available through the software The full version SIGEXPTE adds additional signal processing advanced analysis mixed signal sweeping limit testing and user defined step capabilities and is available for a 30 day trial period standard with each instrument Enables fast and easy communication between a Windows PC and your oscilloscope using USB or LAN Transfer and save settings waveforms measurements and screen images Included Word and Excel toolbars automate the transfer of acquisition data and screen images from the oscilloscope into Word and Excel for quick reporting or further analysis Provides a standard instrument programming interface for common applications such as LabVIEW LabWindows CVI Microsoft NET and MATLAB Enables control of the oscilloscope over a network connection through a standard web browser Simply enter the IP address or network name of the osci
22. com 15 Datasheet Waveform measurements Cursors Automatic measurements time domain Measurement statistics Reference levels Gating Waveform histogram Waveform histogram measurements Waveform math Arithmetic Math functions FFT Advanced math Power Quality Measurements Switching loss measurements Power loss Energy loss Harmonics Ripple measurements Modulation Analysis Safe operating area dV dt and di dt measurements 16 www tektronix com Waveform and Screen 29 of which up to eight can be displayed on screen at any one time Measurements include Period Frequency Delay Rise Time Fall Time Positive Duty Cycle Negative Duty Cycle Positive Pulse Width Negative Pulse Width Burst Width Phase Positive Overshoot Negative Overshoot Peak to Peak Amplitude High Low Max Min Mean Cycle Mean RMS Cycle RMS Positive Pulse Count Negative Pulse Count Rising Edge Count Falling Edge Count Area and Cycle Area Mean Min Max Standard Deviation User definable reference levels for automatic measurements can be specified in either percent or units Isolate the specific occurrence within an acquisition to take measurements on using either the screen or waveform cursors A waveform histogram provides an array of data values representing the total number of hits inside of a user defined region of the display A waveform histogram is both a visual graph of the hit distribution as well as a numeri
23. cumentation CD Accessory bag User manual Power cord OpenChoice Desktop Software NI LabVIEW SignalExpress Tektronix Edition Software Calibration certificate documenting traceability to National Metrology Institute s and ISO9001 quality system registration Three year warranty covering all parts and labor excluding probes 20 www tektronix com Application Modules Mixed Signal Oscilloscopes MSO4000B DPO4000B Series Application modules have licenses which can be transferred between an application module and an oscilloscope The license may be contained in the module allowing the module to be moved from one instrument to another Or the license can be contained in the oscilloscope allowing the module to be removed and stored for safekeeping Transferring the license to an oscilloscope and removing the module permits the use of more than 4 applications simultaneously DPO4AERO DPO4AUDIO DPO4AUTO DPO4AUTOMAX DPO4COMP DPO4EMBD DPO4ENET Aerospace Serial Triggering and Analysis Module Enables triggering on packet level information on MIL STD 1553 buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Signal Inputs Any Ch1 Ch4 Math Ref1 Ref4 Recommended Probing Differential or single ended only one single ended signal required Audio Serial Triggering and Analysis Module Enables tri
24. e Let the oscilloscope do it for you Once you ve set up a bus the MSO DPO4000B Series will decode each packet on the bus and display the value in hex binary decimal USB Ethernet MIL STD 1553 LIN and FlexRay only signed decimal I S LJ RJ TDM only or ASCII USB Ethernet and RS 232 422 485 UART only in the bus waveform Event table In addition to seeing decoded packet data on the bus waveform itself you can view all captured packets in a tabular view much like you would see in a software listing Packets are time stamped and listed consecutively with columns for each component Address Data etc You can save the event table data in csv format Zoom Factor 50 X_ Time Identifier DLC 1 818ms 100 101 M_1 00ms Data f Vertical 00 div 0103 10000001 1122 334455 12345678 1122 3344 5566 7788 1597EEB2 FFFF 0000 EEEE 1111 4269 6C6C 1597EEB2 527DE32 140014 160016 18181818 0 757 TASSAASS 1597EEA3 13 AARNDAOSCHNUWI MRA WUNS AE4F FFF1 0272 DF6B 11 ni22 32 ee 1122 334455 FIF2 F3F4 FSF6 F7 0000 0000 0000 0000 Remote Frame Remote Frame 4568 6C65 7273 DESS CBFA 5D45 ADSC 1122 1122 3344 1122 3344 5566 SDF C1C2 C3C4 B7B6 B4B4 g 20 0us PE i ILIM points J f oy Event table showing decoded identifier DLC DATA and CRC for every CAN packet in a long acquisition Search serial tr
25. e selectable from 2 us to 100 us maximum time selectable from 2 us to 100 us trigger on lt minimum gt maximum inside range outside range RT Address can be further specified to trigger on lt gt lt 2 a particular value or inside or outside of a range Trigger on Word Select Frame Sync or Data Data can be further specified to trigger on lt lt gt 2 a specific data value or inside or outside of a range Maximum data rate for I S LJ RJ is 12 5 Mb s Maximum data rate for TDM is 25 Mb s Trigger on a parallel bus data value Parallel bus can be from 1 to 16 bits from the digital channels plus 2 or 4 bits from the analog channels in size Binary and Hex radices are supported Sample Acquire sampled values Peak Detect Captures glitches as narrow as 800 ps 1 GHz models or 1 6 ns 500 MHz models at all sweep speeds Averaging From 2 to 512 waveforms included in average Envelope Min max envelope reflecting Peak Detect data over multiple acquisitions Hi Res Real time boxcar averaging reduces random noise and increases vertical resolution Roll Scrolls waveforms right to left across the screen at sweep speeds slower than or equal to 40 ms div 2 2350 MHz bandwidth models are recommended for 100BASE TX 3 Trigger selection of Command Word will trigger on Command and ambiguous Command Status words Trigger selection of Status Word will trigger on Status and ambiguous Command Status words www tektronix
26. eed serial bus The yellow waveform is the D and the blue waveform is the D A bus waveform provides decoded packet content including Start Sync PID Address End Point CRC Data values and Stop Capabilities of the serial triggering application modules Mixed Signal Oscilloscopes MSO4000B DPO4000B Series Technology Trigger Bus decode Event table Search Order product Embedded I2C E E E E DPO3EMBD SPI E E E E DPO3EMBD Computer RS232 422 485 UART m m m m DPO3COMP Automotive CAN E E E E DPO3AUTO LIN E E E E DPO3AUTO FlexRay E E E E DPO3FLEX Military and aerospace MIL STD 1553 E E E E DPO3AERO Audio IS m E 7 DPO3AUDIO LJ RJ Bi m m a DPO3AUDIO TDM E m E E DPO3AUDIO Serial triggering Trigger on packet content such as start of packet specific addresses specific data content unique identifiers etc on popular serial interfaces such as IC SPI USB Ethernet CAN LIN FlexRay RS 232 422 485 UART MIL STD 1553 and 2S LJ RJ TDM Bus display Provides a higher level combined view of the individual signals clock data chip enable etc that make up your bus making it easy to identify where packets begin and end and identifying sub packet components such as address data identifier CRC etc Bus decoding Tired of having to visually inspect the waveform to count clocks determine if each bit is a 1 or a0 combine bits into bytes and determine the hex valu
27. g on packet level information on RS 232 422 485 UART buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Signal Inputs Any Ch1 Ch4 and any DO D15 on MSO models Recommended Probing RS 232 UART Single ended RS 422 485 Differential Embedded Serial Triggering and Analysis Module Enables triggering on packet level information on 1 C and SPI buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Signal Inputs IC Any Ch1 Ch4 and any DO D15 on MSO models SPI Any Ch1 Ch4 and any DO D15 on MSO models Recommended Probing Single ended Ethernet Serial Triggering and Analysis Module Enables triggering on packet level information on 10BASE T and 100BASE TX buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Signal Inputs Any Ch1 Ch4 Math Ref1 Ref4 Recommended Probing 10BASE T Single ended or differential 100BASE TX Differential 5 Not available on DPO4102B or DPO4102B L models 6 Only 2 wire SPI is supported on DPO4102B and DPO4102B L models 7 2350 MHz bandwidth models are recommended for 1O0OBASE TX www tektronix com 21 Datasheet DPO4USB DPO4PWR DPO4LM
28. ggering on packet level information on I2S LJ RJ and TDM audio buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Signal Inputs Any Ch1 Ch4 and any DO D15 on MSO models Recommended Probing Single ended Automotive Serial Triggering and Analysis Module Enables triggering on packet level information on CAN and LIN buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Signal Inputs LIN Any Ch1 Ch4 and any DO D15 on MSO models CAN Any Ch1 Ch4 and any DO D15 on MSO models Recommended Probing LIN Single ended CAN Single ended or differential Extended Automotive Serial Triggering and Analysis Module Enables triggering on packet level information on CAN LIN and FlexRay buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools packet decode tables with time stamp information and eye diagram analysis software Signal Inputs LIN Any Ch1 Ch4 and any DO D15 on MSO models CAN Any Ch1 Ch4 and any DO D15 on MSO models FlexRay Any Ch Ch4 and any DO D15 on MSO models Recommended Probing LIN Single ended CAN FlexRay Single ended or differential Computer Serial Triggering and Analysis Module Enables triggerin
29. hannels enables you to acquire fine signal detail up to 60 6 ps resolution around the trigger point for precision timing measurements MagniVu is essential for making accurate timing measurements for setup and hold clock delay signal skew and glitch characterization Trigger On 4 00ms 25 0MS s_ wit LIIM points er ere ere J ips Tx Data D0 Timing Resolution 40 0ns es Fi ET ni Bus f RS 232 A sah Normal Capture Triggering on a specific transmit data packet going across an RS 232 bus A complete set of triggers including triggers for specific serial packet content ensures you quickly capture your event of interest Search Finding your event of interest in a long waveform record can be time consuming without the right search tools With today s record lengths pushing beyond a million data points locating your event can mean scrolling through thousands of screens of signal activity The innovative Wave Inspector controls give you the industry s most comprehensive search and waveform navigation capability These controls Speed panning and zooming through your record With a unique force feedback system you can move from one end of your record to the other in just seconds User marks allow you to mark any location that you may want to reference later for further investigation Or automatically search your record for criteria you define Wave Inspector will instantly search your entire reco
30. iggering Serial triggering is very useful for isolating the event of interest but once you ve captured it and need to analyze the surrounding data what do you do In the past users had to manually scroll through the waveform counting and converting bits and looking for what caused the event You can have the oscilloscope automatically search through the acquired data for user defined criteria including serial packet content Each occurrence is highlighted by a search mark Rapid navigation between marks is as simple as pressing the Previous lt and Next buttons on the front panel www tektronix com 7 Datasheet Power analysis optional Ever increasing consumer demand for longer battery life devices and for green solutions that consume less power require power supply designers to characterize and minimize switching losses to improve efficiency In addition the supply s power levels output purity and harmonic feedback into the power line must be characterized to comply with national and regional power quality standards Historically making these and many other power measurements on an oscilloscope has been a long manual and tedious process The optional power analysis tools greatly simplify these tasks enabling quick and accurate analysis of power quality switching loss harmonics safe operating area SOA modulation ripple and slew rate di dt dv dt Completely integrated into the oscilloscope the power analysi
31. l connector allows for communication control of oscilloscope through USBTMC or GPIB with a TEK USB 488 and direct printing to all PictBridge compatible printers RJ 45 connector supports 10 100 1000 Mb s DB 15 female connector connect to show the oscilloscope display on an external monitor or projector XGA resolution Front panel BNC connector Input Impedance 1 MQ Max input 300 Vays CAT II with peaks lt 425 V Front panel pins 0to2 5V 1 kHz Rear panel BNC connector Vout Hi 22 5 V open circuit 21 0 V 50 Q to ground Vout Lo 0 7 V into a load of lt 4 mA 0 25 V 50 Q to ground Output can be configured to provide a pulse out signal when the oscilloscope triggers the internal oscilloscope reference clock out or an event out for limit mask testing Time base system can phase lock to an external 10 MHz reference 10 MHz 1 Rear panel security slot connects to standard Kensington style lock Standard MIS D 100 100 mm VESA mounting points on rear of instrument LAN eXtensions for Instrumentation LXI Class Version 18 www tektronix com LXI Class C V1 3 Power source Power source voltage Power source frequency Power consumption Physical characteristics Dimensions Weight Rackmount configuration Cooling clearance Mixed Signal Oscilloscopes MSO4000B DPO4000B Series 100 to 240 V 10 50 to 60 Hz 10 at 100 to 240 V 10 400 Hz 10 at 115 V 13 225 W maximum
32. lloscope and a web page will be served to the browser Connect to the oscilloscope through a standard Web browser by simply entering the oscilloscope s IP address or network name in the address bar of the browser The Web interface enables viewing of instrument status and configuration status and modification of network settings and instrument control through the e Scope Web based remote control All Web interaction conforms to LXI Class C specification version 1 3 2350 MHz bandwidth models are recommended for mask testing on telecomm standards gt 55 Mb s 1 GHz bandwidth models are recommended for mask testing on high speed HS USB www tektronix com 17 Datasheet Display system Display type Display resolution Interpolation Waveform styles Graticules Format Maximum waveform capture rate Input output ports USB 2 0 high speed host port USB 2 0 device port LAN port Video out port Auxiliary input Probe compensator output voltage and frequency Amplitude Frequency Auxiliary out External reference input Kensington style lock VESA mount 10 4 in 264 mm liquid crystal TFT color display 1 024 horizontal x 768 vertical pixels XGA Sin x x Vectors Dots Variable Persistence Infinite Persistence Full Grid Cross Hair Frame IRE and mV YT and simultaneous XY YT gt 50 000 wfm s Supports USB mass storage devices printers and keyboard Two ports on front and two ports on rear of instrument Rear pane
33. lude Hub Address Start Complete Don t Care Start SSPLIT Complete CSPLIT Port Address Start and End bits Don t Care Control Bulk Interrupt Full speed Device Low speed Device Isochronous Data is Middle Data is End Data is Start Data is All Endpoint Type Don t Care Control Isochronous Bulk Interrupt Error trigger PID Check CRC5 or CRC16 1 High speed support only available on models with 1 GHz analog channel bandwidth 14 www tektronix com Ethernet optional CAN optional LIN optional FlexRay optional MIL STD 1553 optional I2S LJ RJ TDM optional Parallel available on MSO models only Acquisition system Acquisition Modes Mixed Signal Oscilloscopes MSO4000B DPO4000B Series 10BASE T and 100BASE TX Trigger on Start Frame Delimiter MAC Addresses MAC Q Tag Control Information MAC Length Type IP Header TCP Header TCP IPv4 MAC Client Data End of Packet and FCS CRC Error 100BASE TX Idle MAC Addresses Trigger on Source and Destination 48 bit address values MAC Q Tag Control Information Trigger on Q Tag 32 bit value MAC Length Type Trigger on lt lt gt 2 a particular 16 bit value or inside or outside of a range IP Header Trigger on IP Protocol 8 bit value Source Address Destination Address TCP Header Trigger on Source Port Destination Port Sequence Number and Ack Number TCP IPv4 MAC Client Data Trigger on lt l
34. n types Address can be further specified to trigger on lt lt gt 2 a particular value or inside or outside of a range Frame number can be specified for SOF token using binary hex unsigned decimal and don t care digits Data packet trigger Any data type DATAO DATA1 Data can be further specified to trigger on lt lt gt 2 a particular data value or inside or outside of a range Handshake packet trigger Any handshake type ACK NAK STALL Special packet trigger Any special type PRE Reserved Error trigger PID Check CRC5 or CRC16 Bit Stuffing Trigger on Sync Reset Suspend Resume End of Packet Token Address Packet Data Packet Handshake Packet Special Packet Error Token packet trigger Any token type SOF OUT IN SETUP Address can be specified for Any Token OUT IN and SETUP token types Address can be further specified to trigger on lt lt gt 2 a particular value or inside or outside of a range Frame number can be specified for SOF token using binary hex unsigned decimal and don t care digits Data packet trigger Any data type DATAO DATA1 DATA2 MDATA Data can be further specified to trigger on lt lt gt 2 a particular data value or inside or outside of a range Handshake packet trigger Any handshake type ACK NAK STALL NYET Special packet trigger Any special type ERR SPLIT PING Reserved SPLIT packet components that can be specified inc
35. nnection to networks and a Video Out port allows the oscilloscope display to be exported to an external monitor or projector The instrument can mount external network drives for easy storage of screen images setup files or data files Setup or data files can then be directly recalled and loaded into the oscilloscope from the network drive location The MSO DPO4000B Series is LXI Class C compliant Compact form factor With the compact portable form factor you can easily move the oscilloscope between labs And with a depth of just 5 8 inches 147 mm it saves you valuable space on your test bench Mixed Signal Oscilloscopes MSO4000B DPO4000B Series The MSO DPO4000B Series compact form factor frees up valuable space on your bench or desktop TekVPI probe interface The TekVPI probe interface sets the standard for ease of use in probing In addition to the secure reliable connection that the interface provides TekVPI probes feature status indicators and controls as well as a probe menu button right on the comp box itself This button brings up a probe menu on the oscilloscope display with all relevant settings and controls for the probe The TekVPI interface enables direct attachment of current probes without requiring a separate power supply TekVPI probes can be controlled remotely through USB GPIB or LAN enabling more versatile solutions in ATE environments TekVPI probe interface simplifies connecting your probes to
36. nnel These industry first high impedance passive voltage probes have less than 4 pF of capacitive loading to minimize the affect of the probe on your circuit s operation offering the performance of an active probe with the flexibility of a passive probe A complete set of triggers including runt timeout logic pulse width glitch setup hold violation serial packet and parallel data help you quickly find your event With up to a 20M point record length you can capture many events of interest even thousands of serial packets in a single acquisition for further analysis while maintaining high resolution to zoom in on fine signal details From triggering on specific packet content to automatic decode in multiple data formats the oscilloscope provides integrated support for the industry s broadest range of serial buses IC SPI USB Ethernet CAN LIN FlexRay RS 232 422 485 UART MIL STD 1553 and 2S LJ RJ TDM The ability to decode up to four serial and or parallel buses simultaneously means you gain insight into system level problems quickly To further help troubleshoot system level interactions in complex embedded systems the oscilloscope offers 16 digital channels in addition to its analog channels Since the digital channels are fully integrated into the oscilloscope you can trigger across all input channels automatically time correlating all analog digital and serial signals The MagniVu high speed acquisition on these c
37. nnel digital phosphor oscilloscope www tektronix com 19 Datasheet DPO4104B L DP04104B MS04014B MS04034B MS04054B MS04102B L MS04102B MS0O4104B L MS04104B Standard accessories Probes lt 500 MHz models 1 GHz models MSO models also include Accessories 200 5130 xx 063 4300 xx 016 2030 xx Warranty 1 GHz 5 5 2 5 GS s on 1 2 4 channels 5M record length 4 channel digital phosphor oscilloscope 1 GHz 5 5 5 GS s on 1 2 4 channels 20M record length 4 channel digital phosphor oscilloscope 100 MHz 2 5 2 5 2 5 GS s on 1 2 4 channels 20M record length 4 16 channel mixed signal oscilloscope 350 MHz 2 5 2 5 2 5 GS s on 1 2 4 channels 20M record length 4 16 channel mixed signal oscilloscope 500 MHz 2 5 2 5 2 5 GS s on 1 2 4 channels 20M record length 4 16 channel mixed signal oscilloscope 1 GHz 5 2 5 GS s on 1 2 channels 5M record length 2 16 channel mixed signal oscilloscope 1 GHz 5 5 GS s on 1 2 channels 20M record length 2 16 channel mixed signal oscilloscope 1 GHz 5 5 2 5 GS s on 1 2 4 channels 5M record length 4 16 channel mixed signal oscilloscope 1 GHz 5 5 5 GS s on 1 2 4 channels 20M record length 4 16 channel mixed signal oscilloscope TPP0500 500 MHz bandwidth 10X 3 9 pF One passive voltage probe per analog channel TPP1000 1 GHz bandwidth 10X 3 9 pF One passive voltage probe per analog channel One P6616 16 channel logic probe and a logic probe accessory kit 020 2662 xx Front cover Do
38. quency Duty Cycle and Duty Cycle modulation types Graphical display and mask testing of switching device safe operating area measurements Cursor measurements of slew rate Limit Mask testing optional Included standard masks Test source Mask creation Mask scaling Test criteria run until Violation threshold Actions on test failure Actions on test complete Results display Software NI LabVIEW SignalExpress Tektronix Edition OpenChoice Desktop IVI driver e Scope Web based remote control LXI Class C Web interface Mixed Signal Oscilloscopes MSO4000B DPO4000B Series ITU T ANSI T1 102 USB Limit test Any Ch1 Ch4 or any R1 R4 Mask test Any Ch1 Ch4 Limit test vertical tolerance from 0 to 1 division in 1 m division increments Limit test horizontal tolerance from 0 to 500 m division in 1 m division increments Load standard mask from internal memory Load custom mask from text file with up to 8 segments Lock to Source ON mask automatically re scales with source channel settings changes Lock to Source OFF mask does not re scale with source channel settings changes Minimum number of waveforms from 1 to 1 000 000 Infinity Minimum elapsed time from 1 second to 48 hours Infinity From 1 to 1 000 000 Stop acquisition save screen image to file save waveform to file print screen image trigger out pulse set remote interface SRQ Trigger out pulse set remote interfa
39. r way User marks Press the Set Mark front panel button to place one or more marks on the waveform Navigating between marks is as simple as pressing the Previous lt and Next buttons on the front panel Search marks The Search button allows you to automatically search through your long acquisition looking for user defined events All occurrences of the event are highlighted with search marks and are easily navigated to using the front panel Previous lt and Next buttons Search types include edge pulse width glitch timeout runt logic setup and hold rise fall time parallel bus and I C SPI USB Ethernet CAN LIN FlexRay RS 232 422 485 UART MIL STD 1553 and 2S LU RJ TDM packet content Tek__ Number of Bytes 1 Binary Hex 0001 0001 11 Data a 11h b Id 1818 1818 doa sow N Z 40 0 10 0MS s F 3 01V Bus Search events found 33 1M points Data 11h Search Search Type Source Bus Search For On Bus Identifier BR CAN Id amp Data OXXh Search step 1 You define what you would like to find i ANANAT traniv 4 www tektronix com ED Dat CES ECCONE 101s ep sow Z 20 0ys 10 0MS s f 301v Bus Search events found 33 1M points Search step 2 Wave Inspector automatically searches through the record and marks each event with a hollow white triangle You can then use the Previous and Next buttons to jump from one event to the next Digi
40. rd including analog digital and serial bus data Along the way it will automatically mark every occurrence of your defined event so you can quickly move between events Serre tert A WW Wee Need a Seg p ee al A le f Timing Resolution 100n a Mode Type Source Bus Trigger On Address Data Direction Normal Mark Bus BP 12C iE 50h 2th Read amp Holdo Fea scr cne oe Search IC decode showing results from a Wave Inspector search for Address value 50 Wave Inspector controls provide unprecedented efficiency in viewing and navigating waveform data Analyze Verifying that your prototype s performance matches simulations and meets the project s design goals requires analyzing its behavior Tasks can range from simple checks of rise times and pulse widths to sophisticated power loss analysis and investigation of noise sources The oscilloscope offers a comprehensive set of integrated analysis tools including waveform and screen based cursors automated measurements advanced waveform math including arbitrary equation editing FFT analysis and trend plots for visually determining how a measurement is changing over time Specialized application support for serial bus analysis power supply design and video design and development is also available For extended analysis National Instrument s LabVIEW SignalExpress Tektronix Edition provides over 200 built in functions including time and frequency domain
41. ry stage of debugging your design from quickly discovering an anomaly and capturing it to searching your waveform record for the event and analyzing its characteristics and your device s behavior Discover To debug a design problem first you must know it exists Every design engineer spends time looking for problems in their design a time consuming and frustrating task without the right debug tools The industry s most complete visualization of signals provides fast insight into the real operation of your device A fast waveform capture rate greater than 50 000 waveforms per second enables you to see glitches and other infrequent transients within seconds revealing the true nature of device faults A digital phosphor display with intensity grading shows the history of a signal s activity by intensifying areas of the signal that occur more frequently providing a visual display of just how often anomalies occur 2 50GS s 1000 points ER Ons F tsy Discover Fast waveform capture rate over 50 000 wfm s maximizes the probability of capturing elusive glitches and other infrequent events 2 www tektronix com Capture Discovering a device fault is only the first step Next you must capture the event of interest to identify root cause Accurately capturing any signal of interest begins with proper probing Low capacitance probes are included with the oscilloscope one for each analog cha
42. s tools provide automated repeatable power measurements with a touch of a button no external PC or complex software setup is required s00mvV 106mA XXY 78 Lith d 95 0mW SOA Mask Test Passed Waveforms Acquired 131 Failing Samples 0 a FERA s 1M points _ Safe aca area measurement Automated power measurements enable quick and accurate analysis of common power parameters 2 Beate 4 00ms Wane Limit Mask testing A common task during the development process is characterizing the behavior of certain signals in a system One method called limit testing is to compare a tested signal to a known good or golden version of the same signal with user defined vertical and horizontal tolerances Another common method called mask testing is to compare a tested signal to a mask looking for where a signal under test violates the mask The MSO DPO4000B Series offers both limit and mask testing capability useful for long term signal monitoring characterizing signals during design or testing on a production line A robust set of telecommunications and computer standards are provided to test for compliance to a standard Additionally custom masks can be created and used for characterizing signals Tailor a test to your specific requirements by defining test duration in number of waveforms or time a violation threshold that must be met before considering a test a failure counting hits along with statistical information
43. t gt 2 a particular data value or inside or outside of a range Selectable number of bytes to trigger on from 1 16 Byte offset options of Don t Care 0 1499 Trigger on Start of Frame Frame Type data remote error overload Identifier standard or extended Data Identifier and Data End of Frame Missing ACK or Bit Stuffing Error on CAN signals up to 1 Mb s Data can be further specified to trigger on lt gt 2 or a specific data value User adjustable sample point is set to 50 by default Trigger on Sync Identifier Data Identifier and Data Wakeup Frame Sleep Frame Errors such as Sync Parity or Checksum Errors up to 100 kb s by LIN definition 20 kb s Trigger on Start of Frame Type of Frame Normal Payload Null Sync Startup Identifier Cycle Count Complete Header Field Data Identifier and Data End of Frame or Errors such as Header CRC Trailer CRC Null Frame Sync Frame or Startup Frame Errors up to 100 Mb s Trigger on Sync Word Type Command Status Data Command Word set RT Address T R Sub address Mode Data Word Count Mode Code and Parity individually Status Word set RT Address Message Error Instrumentation Service Request Bit Broadcast Command Received Busy Subsystem Flag Dynamic Bus Control Acceptance DBCA Terminal Flag and Parity individually Data Word user specified 16 bit data value Error Sync Parity Manchester Non contiguous data Idle Time minimum tim
44. tal phosphor technology Digital phosphor technology provides you with fast insight into the real operation of your device Its fast waveform capture rate greater than 50 000 wfm s gives you a high probability of quickly seeing the infrequent problems common in digital systems runt pulses glitches timing issues and more Waveforms are superimposed with one another and waveform points that occur more frequently are intensified This quickly highlights the events that over time occur more often or in the case of infrequent anomalies occur less often You can choose infinite persistence or variable persistence determining how long the previous waveform acquisitions stay on screen This allows you to determine how often an anomaly is occurring Tek Tr SSS U eS 500mvV 3 BT 4 00ns 5 00GS s In 10k points Digital phosphor technology enables greater than 50 000 wfms s waveform capture rate and real time intensity grading Accurate high speed probing The TPP Series probes included standard with every MSO DPO4000B Series oscilloscope provide up to 1 GHz of analog bandwidth and less than 4 pF of capacitive loading The extremely low capacitive loading minimizes adverse affects on your circuits and is more forgiving of longer ground leads And since the probe bandwidth matches or exceeds your oscilloscope bandwidth you can see the high frequency components in your signal which is critical for high speed applications
45. tended with an optional video application module which provides the industry s most complete suite of HDTV and custom nonstandard video triggers Designed to make your work easier See me i te A ke BE 2 ctkak 2 EELDE o DOODLE C agaaaa g u I om The MSO DPO4000B Series is designed to make your work easier The large high resolution display shows intricate signal details Dedicated front panel controls simplify operation Two USB host ports on the front panel allow you to easily transfer screen shots instrument settings and waveform data to a USB mass storage device OOO Large high resolution display The MSO DPO4000B Series features a 10 4 in 264 mm bright LED backlit XGA color display for seeing intricate signal details Dedicated front panel controls Per channel vertical controls provide simple and intuitive operation No longer do you need to share one set of vertical controls across all four channels Connectivity Two USB host ports on the front panel enable easy transfer of screenshots instrument settings and waveform data to a USB mass storage device The rear panel contains two additional USB host ports and a USB device port for controlling the oscilloscope remotely from a PC or for connecting a USB keyboard The USB device port can also be used to print directly to a PictBridge compatible printer An integrated 10 100 1000BASE T Ethernet port enables easy co
46. th higher amplitudes 12 www tektronix com Mixed Signal Oscilloscopes MSO4000B DPO4000B Series Trigger system Trigger modes Auto Normal and Single Trigger coupling DC AC HF reject attenuates gt 50 kHz LF reject attenuates lt 50 kHz noise reject reduces sensitivity Trigger holdoff range 20 ns to 8 s Trigger sensitivity Internal DC coupled Trigger source Sensitivity External Trigger level ranges Any input channel Aux Input external trigger Line Trigger frequency readout 1 MQ path all models For 1 mV div to 4 98 mV div 0 75 div from DC to 50 MHz increasing to 1 3 div at rated bandwidth For 25 mV div 0 4 div from DC to 50 MHz increasing to 1 div at rated bandwidth 0 4 div from DC to 50 MHz increasing to 1 div at rated bandwidth 50 Q path 500 MHz models 50 Q path 1 GHz models Auxiliary Input 200 mV from DC to 50 MHz increasing to 500 mV at rated bandwidth 8 divisions from center of screen 8 divisions from 0 V when vertical LF reject trigger coupling is selected 8 V The line trigger level is fixed at about 50 of the line voltage Provides 6 digit frequency readout of triggerable events Trigger types Edge Positive or negative slope on any channel or front panel auxiliary input Coupling includes DC AC HF reject LF reject and noise reject Sequence B trigger Trigger Delay by Time 4 ns to 8 s Or Trigger Delay by Events 1 to 4 000 0
47. ting and analyzing waveform data Zip through your long record by turning the outer pan control 1 Get details from the beginning to end in seconds See something of interest and want to see more details Just turn the inner zoom control 2 www tektronix com 3 Cg A r q D jaiari Zoom and pan A dedicated two tier front panel control provides intuitive control of both zooming and panning The inner control adjusts the zoom factor or zoom scale turning it clockwise activates zoom and goes to progressively higher zoom factors while turning it counterclockwise results in lower zoom factors and eventually turning zoom off No longer do you need to navigate through multiple menus to adjust your zoom view The outer control pans the zoom box across the waveform to quickly get to the portion of waveform you are interested in The outer control also utilizes force feedback to determine how fast to pan on the waveform The farther you turn the outer control the faster the zoom box moves Pan direction is changed by simply turning the control the other way Play Pause A dedicated Play Pause front panel button scrolls the waveform across the display automatically while you look for anomalies or an event of interest Playback speed and direction are controlled using the intuitive pan control Once again turning the control further makes the waveform scroll faster and changing direction is as simple as turning the control the othe
48. ve Inspector controls for rapid waveform Small footprint and lightweight Only 5 8 in 147 mm deep and 11 Ib navigation automated serial and parallel bus analysis limit and mask 5 kg testing and automated power analysis your Tektronix oscilloscope provides the feature rich tools you need to simplify and speed debug of your Connectivity complex design P 9 Two USB 2 0 host ports on the front panel and two on the rear panel for ee quick and easy data storage printing and connecting a USB keyboard Key performance specifications USB 2 0 device port on the rear panel for easy connection to a PC or 1 GHz 500 MHz 350 MHz and 100 MHz bandwidth models direct printing to a PictBridge compatible printer 2 and 4 analog channel models Integrated 10 100 1000BASE T Ethernet port for network connection Upto 5 GS s sample rate on all channels and video out port to export the oscilloscope display to a monitor or projector Up to 20 mega point record length on all channels gt 90 000 wim s maximum waveform capture rate Standard passive voltage probes with less than 4 pF capacitive loading and 500 MHz or 1 GHz analog bandwidth Suite of advanced triggers Tektronix Datasheet Optional application support Power analysis Limit and mask testing HDTV and custom video analysis Comprehensive features speed every stage of debug These oscilloscopes offer a robust set of features to speed eve

Download Pdf Manuals

image

Related Search

Datasheet datasheet datasheet 360 datasheet pdf datasheet archive datasheet catalog datasheet view datasheet or data sheet datasheet esp32 datasheets360 datasheet4u datasheet lm35 datasheet5 datasheet template datasheet meaning datasheet esp8266 datasheet led datasheet lm358 datasheet search datasheet ne555 datasheet 2n3904 datasheet lm741 datasheet atmega328p datasheet bc547 datasheet view access datasheet arduino nano

Related Contents

TAREAS 5º Grado PRIMARIA Sede Primavera  Máquina perforadora de barrenas    Samsung Wireless Audio-Multiroom WAM250 User Manual  DeLonghi PAC600T Air Conditioner User Manual  Cables Unlimited USB-1870  [fr] Mode d`emploi .............2 [it] Istruzioni per l`uso ........8 [nl  Sony MDR-IF125RK User's Manual  Bedienungsanleitung - ROMMELSBACHER ElektroHausgeräte  Harbor Freight Tools 66995 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file