Home

7 SAVING MEASUREMENT RESULTS - FILE

image

Contents

1. Displays in FILE NAME edition after pressing lt Shift gt and lt lt gt push buttons The edited name is accepted and the file is saved after pressing the lt ENTER gt push button cf the description of the AUTO NAME function The instrument waits then for a reaction of the user any push button should be pressed except the lt Shift gt and lt Alt gt All changes introduced to the file name during the edition are ignored after pressing the lt ESC gt push button This pressing causes the return to the list from which the SAVE SETUP option was entered The AUTO NAME function consists in saving data in the file with the name increased by one in relation to the name displayed in the FILE NAME window Switching on the function is made by selection of NUMBER text in AUTO NAME line The confirmation is made by pressing lt ENTER gt The number can be changed from 0 to N when the only limitation of the N value is the length of the file name which cannot be longer than 8 characters o a SAVE SETUP DEWICE IHTERHAL FILE HAME 5 61 JAHI 5_ 1JAH2 AUTO HAME HUMBER Saved O K PRESS ANY KEY Displays with AUTO NAME function switched on and after saving the file with the increased name The presented below message is displayed after pressing the lt ENTER gt push button in the case when the file with the selected name already exists in the instrument s memory and the REPLACE option is not active path MENU FILE SAVE OPTI
2. LOAD FILE enables one to load to the working space of the instruments memory the measurement results saved in a file LOGGER VIEW enables one to select and present the results stored in the logger s files DELETE enables one to delete a selected file from the instrument s memory DELETE ALL enables one to delete all files from the instrument s memory DEFRAGMENTATION enables one to recover the memory which was used by the deleting files CATALOGUE enables one to overview the catalogue of the files saved in the instrument s memory FREE SPACE informs the user about the capacity of the instrument s memory still available for storing the measurement results SAVE SETUP enables one to set the configuration of the meter SETUP OPTIONS enables one to switch on the saving of user filters coefficients LOAD SETUP enables one to load to the configuration saved in a file Pressing the lt Shift gt and lt A gt or lt Shift gt and lt lt gt results in a movement to the first position of the opened list and pressing the lt Shift gt and lt w gt or lt Shift gt and lt gt gt results in a movement to the last position of the opened list FILE CEFRAGMENMTAT ITOH CATALOGUE SAVE OPTIONS OAD FILE Borers IEW DELETE ALL FILE list In each available position any change is performed by means of the lt lt gt lt gt gt push buttons In order to confirm the selection the lt ENTER gt push button has to be pressed After
3. 23 41 50 5 R SIZE 1346B 5 R RECORDS 5 4 LOGGER VIEW windows with the selection of the logger file to be viewed The results from logger s file coming from different channels are changed after pressing the lt A gt or lt W gt push buttons after each pressing the result from the next channel is displayed 7 10 SVAN 958 USER MANUAL L 12 6 mm s Ti 64 61 Selection of the logger plot from different channels 7 5 Removing a file with the measurement results from memory DELETE The DELETE path MENU FILE DELETE is used to remove a file from memory After pressing the lt ENTER gt push button the instrument checks its current state In the case when the measurements are performed the DELETE position entering is impossible In such case the message with the changing letters is displayed see below and the instrument returns after few seconds to the list from which the DELETE was called FILE list with DELETE text highlighted displayed inversely In the DELETE window there are two elements the RESULT FILES with the measurement results and the SETUP FILES with the saved setups of the instrument In order to enter the selected sub list the user has to select the proper text to display it inversely using the lt A gt lt W gt or lt lt gt lt gt gt push buttons and then press the lt ENTER gt one The DELETE window is closed and the instrument returns to the FILE list after pre
4. oa oa HO RESULTS TO Bl SAVE ALREADY EXISTS Displays after SAVE operation when there is no results to save a and the file with the selected name already exists in the instrument s memory b The data are saved in the file with the name increased by one in relation to the name displayed after switching on of the AUTO NAME option and after pressing the lt ENTER gt push button if the instrument is not measuring and there are the results to be stored The following message containing the name of the file and the operation performed is displayed after the saving of the file Bi MAR Saved D K Display after the execution of SAVE operation 7 4 SVAN 958 USER MANUAL Another message is displayed after successful saving of the file in the memory and then the instrument waits for the reaction of the user any push button should be pressed except the lt Shift gt and lt Alt gt and after pressing a push button it returns to the FILE list The assumptive file s name is displayed after repeated enter to the SAVE position of the FILE list after pressing the lt ENTER gt push button oa oa SAVE SAVE DEWICE INTERNAL FILE NAME 82 7ANe B2JAH1 FILE NAME 82 JAH1 AUTO HAME HUMBER Saved D K AUTO HAME HUMBER a SAVE window AUTO NAME option selected a after saving the file with the increased name b and after repeated enter to SAVE window c It is not possible to store the data in the file which already e
5. pressing the lt lt gt lt gt gt push buttons This position was also established in order not to waste too much memory of the instruments when the self saving is not necessary ao a SAVE OPTIONS SAVE OPTIONS RAM FILE SAUE STATISTICS IH SPECTRUM c c z c IH c MA SPECTRUM L E AUTO SAVE AUTO SAVE SAVE OPTIONS windows with the selection of AUTO SAVE parameters The window for the edition of the base name for the self saved files is opened the AUTO FILE NAME after pressing the lt ENTER gt push button in the case when the AUTO SAVE position is activated The name of the AUTO SAVE files is up to eight characters long starting with the special character a a a AUTO FILE NAME AUTO FILE NAME AUTO FILE NAME aoES1 GRES1239 123456 SH Delete SH i Insert J SH Delete SH gt Insert PSH Delete SH Insert Displays after entering FILE NAME edition mode for the files saved with AUTO SAVE option active after pressing lt ENTER gt push button in SAVE OPTIONS window AUTO SAVE switched on When the AUTO SAVE option is not active OFF after pressing the lt ENTER gt push button the instrument returns to the FILE list 7 2 7 Direct access to SAVE AUTO NAME function DIRECT SAVE The DIRECT SAVE enables one to save measurement results by the simultaneous pressing of the lt ENTER gt and lt Alt gt push buttons after measurement If this option is not active after pressing these push buttons the SA
6. saved in the internal memory of the instrument In order to open the window the user has to press the lt ENTER gt push button when the LOGGER VIEW text is displayed inversely LOAD FILE DELETE DELETE ALL FILE list with LOGGER VIEW text highlighted The storage type INTERNAL is displayed in the first line The current number of the logger file the total number of the saved files and the name of the file are displayed in the second line After pressing the lt lt gt with lt Shift gt push button the first file is available and after pressing the lt gt gt with lt Shift gt push button the last one is displayed Date and time of the SAVE operation is displayed in the third and fourth line The size of the file is displayed in the fifth line The number of records one record is saved after each period equal to logger step is displayed in the last line The change of the current file with the unit step can be done after pressing the lt lt gt lt gt gt push buttons In the right corner in the brackets the number of saved logger results in each channel is displayed e g 5 rvR in the first line means that from the first channel all five available logger results are stored in memory and additionally rpm vector and spectrum RMS are also saved in the selected logger file o o a LOGGER VIEW LOGGER WIEW LOGGER VIEW STORAGE INTERMAL STORAGE INTERHAL STORAGE ie Butfer_i miter 3 a 7 N B 1 JAN 2007 C SryR
7. special message is displayed with the name of the selected file during the execution of the operation see below a a LOAD SETUP PLEASE WAIT S_ 1JAH S_41JAN Loaded O K Loading FILE SIZE 12756 REESS AMY KEY Display during and after the execution of LOAD SETUP operation The next message is displayed after successful end of loading operation The instrument waits for the reaction of the user any push button should be pressed except the lt Shift gt one and after pressing a push button it returns to the FILE list 7 20
8. the name which already exists in the memory depends on the setting of the REPLACE It is possible to erase the old file and to save the new one with the same name if the position is active V The message is displayed that such operation is not available in the case when this position is not active cf the description of the SAVE The activation or deactivation of the REPLACE is done by pressing the lt lt gt lt gt gt push buttons ao a SAVE OPTIONS SAVE OPTIONS RAM FILE SAVE STATISTICS REPLACE AUTO SAVE DIRECT SAVE SAVE OPTIONS windows with the selection of REPLACE After pressing the lt ENTER gt push button the selections made in any position of the window in particular also in the REPLACE position are confirmed and the sub list is closed In the case when the AUTO SAVE option was active V after pressing the lt ENTER gt push button the FILE NAME window is opened for editing the names for AUTO SAVE files The SAVE OPTION window is closed ignoring all settings made in it after pressing the lt ESC gt push button The next position from the SAVE OPTIONS window becomes available after pressing the lt v gt push button 7 7 SVAN 958 USER MANUAL 7 2 6 Controlling of the measurement results savings AUTO SAVE Using the AUTO SAVE one can set the self saving of the measurement results V or to switch off this possibility The activation or deactivation of the AUTO SAVE position is done by
9. ON in which all files are moved to the continuous space In order to illustrate it let us consider the result file named O2JANS5 file which is 746 bytes long The TOTAL AVAILABLE is increased after the DELETE operation but the LOGGER FREE rests unchanged o o o FREE SPACE DELETE FREE SPACE FILES FREE 99 STORAGE THTERNAL FILES FREE 99 16695384 bytes Err 92 0ANS 16895284 bytes TOTAL AVAILABLE LEWEL METER TOTAL AVAILABLE 16696658 bytes 16696796 bytes LOGGER FREE 39 BS LOGGER FREE 39 13717594 bytes 15717594 bytes SVAN 958 USER MANUAL 7 6 Removing all files with measurement results from memory DELETE ALL The DELETE ALL path MENU FILE DELETE ALL is used to remove all files from memory In order to enter the position the user has to select the DELETE ALL text in the FILE list using the lt A gt lt V gt or lt lt gt lt gt gt push buttons and press the lt ENTER gt FILE list with DELETE ALL text highlighted displayed inversely It is possible to select RESULT SETUP and LOGGER files to be deleted The selection is made with lt lt gt lt gt gt push buttons The confirmation is made with pressing lt ENTER gt o o o o DELETE ALL DELETE ALL DELETE ALL DELETE ALL RESULT FILES RESULT FILES RESULT FILES RESULT FILES vf SETUP FILES SETUP FILES DEAL SETUP FILES DEBI SETUP FILES Ex LOGGER FILES LOGGER FILES LOGGER FILES LOGGER FILES Cw DELETE ALL windows and the selection of t
10. ONS REPLACE The instrument then waits for the reaction of the user any push button should be pressed except the lt Shift gt and lt Alt gt and after pressing a push button it returns to the FILE list In such case the user can edit a new start number of a file and then save it using AUTO NAME option o 5_81JAN2 ALREADY EXISTS Displays after SAVE operation when the file with the selected name already exists in the instrument s memory with the message if REPLACE is not active 7 18 SVAN 958 USER MANUAL 7 11 Enabling of saving user filter option SETUP OPTIONS The SETUP OPTIONS path MENU FILE SETUP OPTIONS is used for disabling or enabling the SAVE USER FILTER option In order to enter the position the user has to select the SETUP OPTIONS text in the FILE list using the lt A gt lt v gt push buttons After the selection the lt ENTER gt push button must be pressed The return to the FILE sub list is possible after pressing the lt ESC gt push button oa FILE DEFRAGMENTAT IOW CATALOGUE FREE SPACE SAUE SETUP FILE list with SETUP OPTIONS text highlighted The activation or deactivation of the option is done by pressing the lt lt gt lt gt gt push buttons The confirmation is made by pressing the lt ENTER gt one o o SETUP OPTIONS SETUP OPTIONS SAVE USER FILTER SAWE USER FILTER SETUP OPTIONS window with SAVE USER FILTER selection 7 12 Loading the files with the configura
11. SVAN 958 USER MANUAL 7 SAVING MEASUREMENT RESULTS FILE The registration of the measurement results is an essential task for the efficient use of the instrument All available measurement results can be stored in the FLASH type memory of the instrument There are two main ways for storing the measurement data in the instrument 1 Saving files in the FLASH DISC using the FILE list 2 Logging data in the files of the logger A Notice The instrument s logger memory is independent from the FLASH DISC memory The capacity of available memory is equal to 32 MB Saving files In the case of the SVAN 958 instrument there are few different types of files containing data e from Sound Level Meter mode e from Vibration Level Meter mode e from 1 1 OCTAVE analysis e from 1 3 OCTAVE analysis e from FFT analysis e from RT60 measurements e stored in the instrument s logger A Notice The logger files are created automatically the usage of the SAVE position is not required Each file consists of some elements which are the same for all kind of files e a file header e the unit and software specification e the user s text stored together with the measurement data e the parameters and global settings e the special settings for channels e the marker of the end of the file The other elements of the file structure depend on the type of the file SLM VLM 1 1 OCTAVE or 1 3 OCTAVE analysis logger and on the set
12. TICS position valid only for sound measurements and to save automatically the results of the measurements the AUTO SAVE position The position of the sub list is changed after pressing the lt A gt lt W gt push buttons In order to confirm the selection the lt ENTER gt push button has to be pressed Such pressing closes also the opened window 7 5 SVAN 958 USER MANUAL 7 2 1 Saving files in RAM memory RAM FILE The RAM FILE enables the user to save the results of the measurement in the special file in RAM memory the name of the file is defined as a RAMfile The activation or deactivation of the RAM FILE is done by pressing the lt lt gt lt gt gt push buttons This option is useful when remote reading is necessary available values V or ao ao SAVE OPTIONS SAVE OPTIONS RAM FILE RAM FILE wf SAVE STATISTICS SAVE STATISTICS c c OF c UTO SAVE I UTO SAVE DIRECT SAVE DIRECT SAVE SAVE OPTIONS windows with the selection of RAM FILE parameters 7 2 2 Controlling of the measurement statistics savings SAVE STATISTICS The SAVE STATISTICS is used to set self saving together with the sound measurement results the statistics of the measurements V or to switch off this possibility Together with the sound measurements 100 class statistics is performed the values named from L01 to L99 The statistics are not calculated for the vibration measurements The activation or deactivation of the SA
13. UM saving F 7 6 SVAN 958 USER MANUAL To see the MINIMUM values on the display during the real time 1 1 OCTAVE or 1 3 OCTAVE analysis the user has to activate the option in the DISPLAY list path MENU DISPLAY DISPLAY SETUP CHANNEL x SPECTRUM VIEW MINIMUM 7 2 4 Saving maximum values in the spectrum MAX SPECTRUM The MAX SPECTRUM appears on the display in the case of 1 1 OCTAVE and 1 3 OCTAVE mode and it enables the user to save the highest values of the instantaneous spectrum calculated with 100 milliseconds time step which occurred during the INT PERIOD set in the INPUT list path MENU INPUT MEASUREMENT SETUP INT PERIOD The activation or deactivation of the MAX SPECTRUM is done by pressing the lt lt gt lt gt gt push buttons After pressing the lt ENTER gt push button the activation is confirmed The SAVE OPTION window is closed ignoring all settings made in it after pressing the lt ESC gt push button a a SAVE OPTION SAVE OPTIONS C c c o i AUTO SALUE F SAVE OPTIONS windows with the selection of MAX SPECTRUM saving F To see the MAXIMUM values on the display during the real time 1 1 OCTAVE or 1 3 OCTAVE analysis the user has to activate the option in the DISPLAY list path MENU DISPLAY DISPLAY SETUP CHANNEL x SPECTRUM VIEW MAXIMUM 7 2 5 Replacement of the existing files by the new ones REPLACE The result of the attempt to save the file with
14. VE STATISTICS is done by pressing the lt lt gt lt gt gt push buttons A Notice This position was created to save the memory of the instrument in the case when the knowledge of the statistics is not necessary Each registration of the statistics requires 600 bytes of the memory a ao SAVE OPTIONS SAVE OPTIONS RAM FILE SAVE STATISTICS REPLACE AUTO SAVE DIRECT SAVE DIRECT SAVE SAVE OPTIONS windows with the selection of SAVE STATISTICS After pressing the lt ENTER gt push button the selections made in any position of the list in particular also in the SAVE STATISTIC are confirmed and the window is closed 7 2 3 Saving minimum values in the spectrum MIN SPECTRUM The MIN SPECTRUM appears on the display in the case of 1 1 OCTAVE and 1 3 OCTAVE mode and it enables the user to save the lowest values of the instantaneous spectrum calculated with 100 milliseconds time step which occurred during the INT PERIOD set in the INPUT list path MENU INPUT MEASUREMENT SETUP INT PERIOD The activation or deactivation of the MIN SPECTRUM is done by pressing the lt lt gt lt gt gt push buttons After pressing the lt ENTER gt push button the activation is confirmed The SAVE OPTION window is closed ignoring all settings made in it after pressing the lt ESC gt push button a a SAVE OPTION SAVE OPTIONS F c c c o AUTO SAVE SAVE OPTIONS windows with the selection of MIN SPECTR
15. VE window is accessed if the measurements are not performed If the option is active V after pressing the lt ENTER gt and lt Alt gt push buttons the results are saved in the file with the automatically incremented name and the proper message is displayed for a few seconds The proper setting of the DIRECT SAVE is done by pressing the lt lt gt lt gt gt push buttons a SAVE OPTIONS ao SAVE OPTIONS RAM FILE RAM FILE J SAVE STATISTICS lt gt gt SAVE STATISTICS 1 REFLACE c el UTO SAVE g OF DIRECT SAVE cv UTO SAVE DIRECT SAVE SAVE OPTIONS windows with the selection of DIRECT SAVE 7 3 Loading the files with the measurement results LOAD FILE The LOAD path MENU FILE LOAD is used for loading data file from the FLASH DISC e g for the verification or comparison The position is opened after pressing the lt ENTER gt push button when the LOAD text in the FILE list is displayed inversely selected using the lt A gt lt W gt or lt lt gt lt gt gt push buttons The return to the FILE list is possible after pressing the lt ESC gt push button 7 8 SVAN 958 USER MANUAL LOGGER IJIEW DELETE DELETE ALL FILE list with LOAD FILE text highlighted displayed inversely A Notice It is not possible to load the file during the execution of the measurements On such attempt the message measurement in progress MEASUREMENT IN PROGRESS is displayed for about 2 seconds Afte
16. aved file s name in the case of the next entering It is possible to edit this name in two ways full and with AUTO NAME option The SAVE window with FILE NAME edition is presented on the Figure below The displayed inversely character is currently edited The lt A gt lt W gt lt lt gt lt gt gt and lt Shift gt push buttons are used for editing the name which cannot exceed 8 characters Displays during the file s name edition The user can select the proper position of the character in the edited text using the lt lt gt lt gt gt push buttons The available ASCII characters can be changed using the lt A gt lt v gt push buttons The subsequent big letters digits space and underline appear on the display in the inversely displayed position after each pressing of the mentioned above push buttons The empty space is created for the introduction of a new character in the edited name the Insert operation is executed when the lt Shift gt push button is pressed together with the lt gt gt AUTO HAME OFF f AUTO HAME Displays in FILE NAME edition after pressing lt Shift gt and lt gt gt push buttons 7 3 SVAN 958 USER MANUAL The character which is highlighted displayed inversely is deleted from the edited name the Delete operation is executed when the lt Shift gt and lt lt gt push buttons are pressed oa SAVE DEWICE IHTEFHAL JJ CEWICE FILE HAME 4i8MAR AUTO HAME Di
17. ed The change of the current file with the unit step can be done pressing the lt lt gt lt gt gt push buttons After pressing the lt lt gt with lt Shift gt push button the first file is available and after pressing the lt gt gt with lt Shift gt push button the last one is displayed The return to the FILE list is possible after pressing the lt ESC gt push button 3 2 2 FILE SIZE 7466 FILE SIZE 7466 FILE SIZE 7466 DELETE windows with the selection of the file to be deleted The name of the file is accepted and the file is deleted after pressing the lt ENTER gt push button The message is displayed after the successful end of the operation The instrument waits for the reaction of the user any push button should be pressed except the lt Shift gt one and after pressing a push button it returns to the FILE list o i234571 DELETED 0 K Execution of DELETE operation After the execution of the result files removing from the memory usually the FILES FREE memory path MENU FILE FREE SPACE rests the same as before the deletion but TOTAL AVAILABLE memory is increased It is because erased file was located somewhere inside the file s space The file is no longer accessible but the recuperated memory is still unused for the next saving All new files are stored starting at the end of the last saved file The memory becomes available after the defragmentation process path MENU FILE DEFRAGMENTATI
18. he files to be deleted The instrument requests the confirmation of the operation after entering this position after pressing the lt ENTER gt push button The next pressing of the lt ENTER gt push button when the NO option is selected causes the closing of the position and the return to the FILE list The selection of the NO or YES option is possible using the lt lt gt lt gt gt push buttons The return to the FILE list is possible after pressing the lt ESC gt push button a a DELETE ALL DELETE ALL P Are you sure gri Are you sure YES Hol PES Ho Displays during the execution of DELETE ALL operation After pressing the lt ENTER gt push button the instrument checks its current state In the case when the measurements are performed the execution of the DELETE ALL operation is not possible In such case the message with the changing letters is displayed see below and the instrument returns after few seconds to the list from which the DELETE ALL was called ao a o DELETE ALL DELETE ALL P Are you sure Are you sure YES Ho WES HO Displays with the not possible confirmation of DELETE ALL order during the measurement The lt ENTER gt push button pressing when the YES option is selected and the instrument is not performing the measurements deletes all existing files In this case the text displayed below is presented In this time the instrument recovers and clears the memory which was used by sa
19. on is displayed in the fifth line The size of the loaded file is given in the sixth line The change of the current file with the unit step can be done after pressing the lt lt gt lt gt gt push buttons After pressing the lt lt gt with lt Shift gt push button the first file is available and after pressing the lt gt gt with lt Shift gt push button the last one is displayed m m o LOAD FILE LOAD FILE LOAD FILE FILE SIZE 7466 FILE SIZE 8826 FILE SIZE 46266 Displays during the overview of the file list 7 9 SVAN 958 USER MANUAL The name of the file is accepted and the file is loaded after pressing the lt ENTER gt push button After successful end of loading operation instrument waits for the reaction of the user any push button should be pressed except the lt Shift gt and lt Alt gt and after pressing a push button it returns to the FILE list ao oa LOAD FILE INTERHAL 1234571 mi234571 CUULIS f Loaded O E FFT LOGGER NAME Buffe_i4 83 JAH 2007 1 45 36 FILE SIZE 46266 Execution of the LOAD FILE operation The next message is displayed after successful end of loading operation The instrument waits for the reaction of the user any push button should be pressed except the lt Shift gt one and after pressing a push button it returns to the FILE list 7 4 Checking the contents of the loaded file LOGGER VIEW The LOGGER enables the user to examine the contents of the logger files
20. r pressing the lt ENTER gt push button the instrument checks its current state In the case when the measurements are performed the file loading is impossible In such case the message with the changing letters is displayed see below and the instrument returns after few seconds to the list from which the LOAD was called ao g o y T MEASUREMENT IH T measurement in H PROGRESS H Progress Displays with the message stating the reason for unfeasibility of the required operation In the case when the instrument memory is empty no file is stored the NO FILES text is displayed after entering LOAD and the instrument waits for the reaction of the user The user should press then the lt ESC gt lt ENTER gt or lt Start Stop gt push button ao LOAD FILE STORAGE LBB NO FILES FILE SIZE r366 Displays during the execution of LOAD FILE operation The text informing the user that file was loaded from the internal memory of the instrument is given in the first line The current number of the file and the total number of the saved files is displayed inversely in the second line together with the name of the file The type of the current file LEVEL METER 1 1 OCTAVE 1 3 OCTAVE etc and measure mode in each of four channels Sound or Vibration are given in the third line If the file contains the results from the logger the name of the logger file is displayed at the right end of the fourth line Date and time of the SAVE operati
21. sh button o o DEFRAGNHENTATION DEFRAGNENTATION gri Are you sure P Are you sure YES m i HO Displays before the execution of DEFRAGMENTATION operation The lt ENTER gt push button pressing when the YES option is selected and the instrument is not performing the measurements merges the memory The presented below message is displayed in the case when the operation is not required The instrument waits for the reaction of the user any push button should be pressed except the lt Shift gt and lt Alt gt and after pressing a push button it returns to the FILE list The operation is not executed in a case when FREE SPACE is equal to TOTAL AVAILABLE o DEFRAGNENTATION P Are you sure PES Ho Display in the case when DEFRAGMENTATION operation is not required 7 14 SVAN 958 USER MANUAL In the case when the DEFRAGMENTATION operation is performed the following texts are displayed see below ao oa PLEASE WAIT x DEFRAGMENT ING DEFRAGMENTATION I HTERHAL FILE finished STORAGE Displays during the execution of DEFRAGMENTATION operation In this time the instrument recovers clears and merges in one block the memory which was used by the deleted files The presented below message is displayed after successful memory merging see Fig c The instrument waits for the reaction of the user any push button should be pressed except the lt Shift gt and lt Alt gt and after pressing a push button it returns
22. splays in FILE NAME edition after pressing lt Shift gt and lt lt gt push buttons The edited name is accepted and the file is saved after pressing the lt ENTER gt push button cf the description of the AUTO NAME function The instrument waits then for a reaction of the user any push button should be pressed except the lt Shift gt and lt Alt gt All changes introduced to the file name during the edition are ignored after pressing the lt ESC gt push button This pressing causes the return to the list from which the SAVE option was entered The simplified edition consists in the addition at the end of the file name the natural number increased by one after each saving This option is available after selecting the AUTO NAME text with lt A gt lt w gt push buttons and switching it on using lt gt gt one oa SAVE INTERNAL J CEWICE INTERNAL FILE NAME amp iMAR AUTO HAME HUMBER SAVE window with AUTO NAME function selection The presented below message Fig a is displayed after pressing the lt ENTER gt push button in the case when no measurements were performed and there are no results to be saved The operation cannot be done also in a case when the file of the selected name already exists in the instrument s memory Fig b The instrument then waits for the reaction of the user any push button should be pressed except the lt Shift gt one and after pressing a push button it returns to the SAVE position
23. ssing the lt ESC gt one oa DELETE FE SU 5 RESULT FILES SETUP FILES SETUP FILES DELETE windows opened with RESULT FILES and SETUP FILES selected After pressing the lt ENTER gt push button the instrument checks its current state In the case when the measurements are performed the RESULT FILES or SETUP FILES entering is impossible In such case the message is displayed and the instrument returns after few seconds to the DELETE window ao g o y T MEASUREMENT IH T measurement in Li PROGRESS Progress Displays with the message stating the reason for unfeasibility of the required operation In the case when the instrument memory is empty no file is stored the NO FILES text is displayed after entering DELETE and the instrument waits for the reaction of the user The user should press then the lt ESC gt lt ENTER gt or lt Start Stop gt push button SVAN 958 USER MANUAL o DELETE STORAGE IHTERHAL Can a C art NO FILES DELETE window when the memory of the instrument is empty The same data about the existing in the instrument files as in the LOAD window are displayed on the display after successful opening the DELETE window pressing the lt ENTER gt push button In the consecutive lines of the display the memory in which the results are saved in INTERNAL the current file number the total number of the files the file name the file type date and period of registration and the file size are present
24. t In order to enter the position the user has to select the FREE SPACE text in the FILE list using the lt A gt lt w gt or lt lt gt lt gt gt push buttons and press the lt ENTER gt The return to the FILE list is possible after pressing the lt ESC gt or lt ENTER gt push button CATALOGUE FILE list with FREE SPACE text highlighted displayed inversely The memory of the instrument is divided into two separate parts One part is dedicated for saving the result and setup files and its size is equal to 16121360 bytes The second part is used for saving the logger files and its size is equal to 15728156 bytes The FREE SPACE window in the instrument after the execution of the DELETE ALL operation is presented below oa FREE SPACE FILES FREE ise 16121368 bytes TOTAL AVAILABLE 16121366 bytes LOGGER FREE 100 15726156 bytes FREE SPACE window after the execution of the DELETE ALL operation The FREE SPACE window contains three numbers First two named FILES FREE and TOTAL AVAILABLE characterise the result and setup files memory The files are always saved starting from the beginning of the continuous memory space The size in bytes of this space is given in the FILES FREE window If the result and setup files were not deleted from the memory the number of bytes displayed in the TOTAL AVAILABLE window is the same as in the FILES FREE SPACE However if some of them were deleted assuming that they were no
25. t the last saved the memory used by them is empty but it does not increase the continuous space 7 16 SVAN 958 USER MANUAL In such case the number given in the TOTAL AVAILABLE window is greater than that in the FILES FREE The DEFRAGMENTATION operation which merges files should be used to increase the FILES FREE space oa FREE SPACE FILES FREE 99 6116328 bytes TOTAL AVAILABLE 16116326 bytes LOGGER FREE 39 15643384 bytes FREE SPACE window with the number depending on the measurements and operations performed 7 10 Saving setup in the instrument s memory SAVE SETUP The SAVE SETUP path MENU FILE SAVE SETUP is used for storing data in the FLASH DISC memory of the instrument as a file see Appendix B for the file formats In order to enter the position the user has to select the SAVE SETUP text in the FILE list using the lt A gt or lt lt gt push button After the selection the lt ENTER gt push button must be pressed The additional function for results saving the AUTO NAME save a file with the name automatically increased by one is available after selection of the NUMBER text in AUTO NAME line The return to the FILE sub list is possible after pressing the lt ESC gt push button FILE list with SAVE SETUP text highlighted displayed inversely a ao SAVE SETUP FILE MAME 5_61JAH 5 81 JAH H OFF Saved D K AUTO HAME SAVE SETUP window The name of the file in which the config
26. this confirmation the opened window or list is closed In order to ignore any changes made in the opened window or list the user has to press the lt ESC gt push button 7 2 SVAN 958 USER MANUAL 7 1 Saving files in the instrument s memory SAVE and AUTO NAME The SAVE path MENU FILE SAVE is used for storing data in the internal non volatile FLASH DISC memory as a file see Appendix B for the file formats In order to enter the position the user has to select the SAVE text in the FILE list using the lt A gt or lt lt gt push button the window is opened also by pressing lt Alt gt together with lt ENTER gt after the measurement After the selection the lt ENTER gt push button must be pressed DELETE ALL FILE list with SAVE text highlighted displayed inversely The additional function for results saving AUTO NAME save a file with the name increased by one is available after selecting the AUTO NAME text with lt A gt lt v gt push buttons and switching it on using lt gt gt push button The return to the FILE list is possible after pressing the lt ESC gt push button oa SAUVE FILE NAME 5 7AH AUTO HAME OFF SAVE window opened The name of the file in which the measurements or the analysis results are to be saved is displayed in the second line FILE NAME The default name for a file is displayed in the case of the first entering to this position after power on and the last s
27. ting of SAVE STATISTIC path MENU FILE SAVE OPTIONS SAVE STATISTIC These elements are as follows e the main results e the results coming from 1 1 OCTAVE analysis e the results coming from 1 3 OCTAVE analysis e the results from FFT analysis e the results from RT60 mode e the statistics header e the results of statistical analysis e the header of the statistical analysis performed in 1 1 OCTAVE or 1 3 OCTAVE analysis e the results of the statistical analysis performed in 1 1 OCTAVE or 1 3 OCTAVE analysis e the header of the logger s file 7 1 SVAN 958 USER MANUAL e the data stored during the measurements in the files of the logger A Notice The detailed description of all types of file structures is given in the Appendix B Storing the measurement results as files in the instrument s FLASH DISC can be done by means of the FILE list In order to open this list the user has to e press the lt Menu gt push button e select from the main list using the lt A gt lt w gt or lt lt gt lt gt gt push buttons the FILE text highlight it inversely e press the lt ENTER gt push button SETUP AUXILIARY FUNCTIONS Main list with FILE text highlighted displayed inversely The FILE list contains the following items SAVE enables one to save the measurement results as a file in the instrument memory SAVE OPTIONS enables one to set the options of the measurement result savings
28. tion LOAD SETUP The LOAD SETUP path MENU FILE LOAD SETUP is used for loading data file from the FLASH DISC The position is opened after pressing the lt ENTER gt push button when the LOAD SETUP text in the FILE list is displayed inversely selected using the lt A gt lt W gt or lt lt gt lt gt gt push buttons The return to the FILE list is possible after pressing the lt ESC gt push button a FILE DEFRFAGMEHTATIOH CATALOGUE FREE SPACE SAVE SETUP SETUP OPTIONS FILE list with LOAD SETUP text highlighted displayed inversely A Notice It is not possible to load the file during the execution of the measurements On such attempt the message measurement in progress MEASUREMENT IN PROGRESS is displayed for about 2 seconds After pressing the lt ENTER gt push button the instrument checks its current state In the case when the measurements are performed the file loading is impossible In such case the message with the changing letters is displayed see below and the instrument returns after few seconds to the list from which the LOAD was called 7 19 SVAN 958 USER MANUAL ao g o y T MEASUREMENT IH T measurement in H PROGRESS H Progress Displays with the message stating the reason for unfeasibility of the required operation In the case when the instrument memory is empty no file is stored the NO FILES text is displayed after entering the LOAD SETUP window and the instr
29. to the FILE list The result of the DEFRAGMENTATION operation is visible below in Fig d FILES FREE space is increased while the state of the memory before the execution of this operation is given in Fig b and before DELETE operation in Fig a ao a oa a FREE SPACE FREE SPACE ___ FREE SPACE FILES FREE 99 FILES FREE 99 FILES FREE 99 16692342 bytes 16692342 bytes DEFRAGMENTAT IOH 16895384 bytes TOTAL AVAILABLE TOTAL AVAILABLE finished TOTAL AVAILABLE 16692342 bytes 16695364 bytes 16695384 bytes LOGGER FREE 39 LOGGER FREE 39 LOGGER FREE 99 a 13717594 bytes b 15717594 bytes i 15717594 bytes Displays with the state of the file s memory before DELETE operation a after DELETE operation b after the execution of DEFRAGMENTATION operation c and the state of the memory after the execution of the operation d 7 8 Checking the contents of the memory CATALOGUE The CATALOGUE is used for checking the contents of the memory the list of the files In order to enter the window the user has to select the CATALOGUE text in the FILE list using the lt A gt lt v gt or lt lt gt lt gt gt push buttons and press the lt ENTER gt a FILE LOAD FILE LOGGER WIEW DELETE DELETE ALL DEFRAGMENTATION FILE list with CATALOGUE text highlighted In the case when the instrument memory is empty no file is stored or after DELETE ALL operation the NO FILES text is displayed after entering the CATALOGUE
30. ument waits for the reaction of the user The user should press then the lt ESC gt lt ENTER gt or lt Start Stop gt push button a a LOAD SETUP LOAD SETUP STORAGE LC Arh ETUP i JAN 2007 03 01 20 HO FILES FILE SIZE 12786 Displays during the execution of LOAD SETUP operation The text informing the user that file was loaded from the internal memory of the instrument is given in the first line The current number of the file and the total number of the saved files are displayed inversely in the second line together with the name of the file The SETUP type of the current file is given in the third line Date and time of the SAVE operation is displayed in the fourth line The file size is given in the fifth line The change of the current file with the unit step can be done after pressing the lt lt gt lt gt gt push buttons After pressing the lt lt gt with lt Shift gt push button the first file is available and after pressing the lt gt gt with lt Shift gt push button the last one is displayed oa oa a LOAD SETUP LOAD SETUP LOAD SETUP THTERHAL STORAGE THTERHAL IHTERHAL 5_81JAH 24 S_81JANS Sd 5 61JAH1 eN 5 F ee ETU ETU 61 JAH 2687 83 81 28 61 JAH 2687 83 81 54 61 JAH 2687 83 82 82 FILE SIZE 12756 FILE SIZE 12756 FILE SIZE 12756 Displays during the overview of the file list The name of the file is accepted and the file is loaded after pressing the lt ENTER gt push button The
31. uration of meter is saved is displayed in the second line The default name for a file is displayed in the case of the first entering to this position after power on and the last saved file s name in the case of the next entering It is possible to edit this name or to save a file using AUTO NAME option save a file with the name automatically increased by one The edition of the FILE NAME is made using the lt A gt lt v gt push buttons pressed together with lt Shift gt One can select the character to be edited using the lt lt gt lt gt gt push buttons a a SAVE SETUP SAVE SETUP Displays during the process of setting the character in the edited name SVAN 958 USER MANUAL The empty space is created for the introduction of a new character in the edited name the Insert operation is executed when the lt Shift gt push button is pressed together with the lt gt gt a a a SAVE SETUP SAVE SETUP SAVE SETUP THTERMAL JJ CEWICE THTERNAL JJ CEWICE AUTO HAME HUMBER f AUTO HAME HUMBER f AUTO HAME Displays in FILE NAME edition after pressing lt Shift gt and lt gt gt push buttons The character which is displayed inversely is deleted from the edited name the Delete operation is executed when the lt Shift gt and lt lt gt push buttons are pressed a a a SAVE SETUP SAVE SETUP SAVE SETUP IHTERHAL J CEWICE IHTERHAL J CEWICE AUTO HAME HUMBER f AUTO HAME HUMBER f AUTO HAME
32. ved files 7 13 SVAN 958 USER MANUAL a ao DELETE ALL PLEASE WAIT x CLEARING FILES DELETED O K gri Are you sure IHTERHAL FILES STORAGE FESI HO z Displays during the execution of DELETE ALL operation and after this execution The message is displayed after the successful execution of the operation The instrument waits for the reaction of the user any push button should be pressed except the lt Shift gt and lt Alt gt and after pressing a push button it returns to the FILE list 7 7 Memory merging DEFRAGMENTATION The DEFRAGMENTATION path MENU FILE DEFRAGMENTATION is used to merge the blocks of the memory which were released after the delete operation In order to enter the position the user has to select the DEFRAGMENTATION text in the FILE list using the lt A gt lt v gt or lt lt gt lt gt gt push buttons and press the lt ENTER gt FILE SAVE OPTIONS OAD FILE LOGGER IEW DELETE DELETE ALL FILE list with DEFRAGMENTATION text highlighted The instrument requests the confirmation of the operation after entering this position after pressing the lt ENTER gt push button The next pressing of the lt ENTER gt push button when the NO option is selected causes the closing of the window and the return to the FILE list The selection of the NO or YES option is possible using the lt lt gt lt gt gt push buttons The return to the FILE list is possible after pressing the lt ESC gt pu
33. window and the instrument waits for the reaction of the user The user should press then the lt ESC gt lt ENTER gt or lt Start Stop gt push button The same data about the existing in the instrument files as in the LOAD FILE window are displayed on the display after opening CATALOGUE In the consecutive lines of the display the memory in which the results are saved the current file number the total number of the files the file name the file type date and time of registration are presented The change of the current file with the unit step can be done pressing the lt lt gt lt gt gt push buttons After pressing the lt lt gt with lt Shift gt push button the first file is available and after pressing the lt gt gt with lt Shift gt push button the last one is displayed The return to the FILE list is possible after pressing the lt ESC gt or lt ENTER gt push button 7 15 SVAN 958 USER MANUAL Oo CATALOGUE STORAGE IHTERHAL Can C art MO FILES Displays with the contest of CATALOGUE operation when the memory is empty ol ol ol CATALOGUE CATALOGUE CATALOGUE seer STORAGE STORAGE THTERHAL C iio E 1 1 OCTAVE AN 2007_00 41 FILE SIZE 7466 FILE SIZE 7466 FILE SIZE 8826 Exemplary contents of CATALOGUE window 7 9 Checking the free space in the memory FREE SPACE The FREE SPACE path MENU FILE FREE SPACE is used to read out the free space in the FLASH DISC memory of the instrumen
34. xists when the REPLACE position is not active The presented below message is displayed after pressing the lt ENTER gt push button in the case when during the name edition process the user selected the name which was used before The instrument then waits for the reaction of the user any push button should be pressed except the lt Shift gt and lt Alt gt and after pressing a push button it returns to the FILE list oa SAVE DEWICE INTERNAL FILE NAME amp 1JAH 81 JANG AUTO HAME HUMBER ALREADY EXISTS a Displays after the file s name selection a and with the message if REPLACE option is not active b 7 2 Controlling the data storing in the instrument s memory SAVE OPTIONS The SAVE OPTIONS path MENU FILE SAVE OPTIONS is used for the selection of the options of data storing in the FLASH DISC memory of the instrument The window is opened after pressing the lt ENTER gt push button when the SAVE OPTIONS text in the FILE list is displayed inversely selected using the lt A gt lt W gt or lt lt gt lt gt gt push buttons The return to the FILE list is possible after pressing the lt ESC gt push button LOAD FILE LOGGER VIEW DELETE ALL FILE list with SAVE OPTIONS text highlighted displayed inversely It is possible to replace the existing in the memory file by the new one with the same name the REPLACE position to add to the results the statistics of the measurements the SAVE STATIS

Download Pdf Manuals

image

Related Search

Related Contents

Targus THZ20002EU  V7 Lightweight Stereo Headset  Samsung CT-15K2F User Manual  テクニカル インフォメーション  "取扱説明書"  Samsung 11,6 tommer ATIV Smart PC Pro XE700T1C User Manual (Windows 8)  release_note_2010_updated.txt Release notes for SAFNWC  Le livret de la JDC 2012  User Manual    

Copyright © All rights reserved.
Failed to retrieve file