Page 1 USER MANUAL PROTON POWER CONTROL PVT. LTD

image

Contents

1. mm 4 Terminal Screw ON Terminals KEY S e SET This key is used to change the controller from RUN mode to FUNCTION mode for Parameter setting amp to save the modified setting in Function mode INC Up scroll the parameter amp parameter value DEC Down scroll the parameter amp parameter value LED S 1 UV RED Under Voltage Fault 2 OV RED Over Voltage Fault 3 SPP UB RP RED SPP Voltage Unbalance amp Reverse Phase Fault 4 UL CUB RED Under Load amp Current Unbalance Fault 5 OL RED Over Load Fault 6 Relay Green Supply Healthy No fault WORKING Run Mode At Power On under normal working condition Relay indication led will blink and glow steady after power on delays Steady glow of Relay led indicates Relay on condition Unit will enter Run Mode and will have a scrolling parameter display consisting of R Y Voltage Y B Voltage B R Voltage amp R Y B current drawn by each phase In Run mode Relay may turn OFF depending on the occurrence of fault ALARM indications for the particular fault will blink on the front panel of unit Faults such as over under load will turn off relay and faults such as over under voltage will turn off voltage relay Manual control for restart after occurrence clearance of fault has been programmed therefore user has to press decrement key to restart the unit The unit will resume Run mode if fault disappears after delay The Front panel p
2. NOTE 3 numbers can be stored in the phonebook Syntax REG lt space gt NUM lt space gt represents 10 digit mobile number Eg 1 If user sends USER MANUAL PROTON POWER CONTROL PVT LTD PUNE REG NUM1 9191919191 To the controller the controller writes the mobile number 9191919191 to the 1 location of phonebook Eg 2 If user sends REG NUM2 9191919191 To the controller the controller writes the mobile number 9191919191 to the 2 location of phonebook NOTE 3 numbers can be stored in the phonebook Eg 3 If user sends REG NUM3 9191919191 To the controller the controller writes the mobile number 9191919191 to the 3 location of phonebook NOTE 3 numbers can be stored in the phonebook NOTE 1 If any fault occurs to the motor controller will send sms only to the 3 numbers registered in the phonebook 2 Motor can be Started Stopped by sending START STOP sms through any number 3 If STATUS Sms is sent to the controller the controller will reply the motor status only to the number from which STATUS sms was received Thus any number can inquire the controller status Function Mode Function key is used to enter Function mode to view change settings When function key is pressed for 2 3 seconds then pwrd message is displayed and then 0000 user can change the password by pressing increment and decrement keys to enter the
3. USER MANUAL PROTON POWER CONTROL PVT LTD PUNE GSM BASED MOTOR PROTECTION UNIT Salient Features Fully programmable No auxiliary power supply required for controller operation SMS controlled start stop and remote monitoring Complete protection from electrical unhealthy condition All parameters are password protected All parameters are settable through front key LED indications for alarm fault Scrolling display of parameters one by one in scroll mode Onsite Voltage and current Calibration 0 Four bright 7 segment display on unit 1 Inverse Time trip curve for over load fault Ry O00 SON Oe Ph The Motor protection unit continuously scans the faults like Under Voltage Over Voltage SPP Reverse Phase Voltage Unbalance Under Load Over Load Current unbalance Technical Specification Input Supply 3 Phase 415 V 50 HZ AC 3 Phase 4 wire Input Current 0 18 A per phase Accuracy 1 Voltage 0 25 1 dgts 2 Current 0 25 1 dgts Output contact Rating 3 Pole 415V 18Amp Contactor 7 A at 250 volt Auxiliary Power No External power is required Draws power from the voltage signal Inputs GSM MODEM Quad Band 850 900 1800 1900 MHz Environmental 1 Working Temp 0 to 55 C 2 Storage Temp 10 to 70 C 3 Relative humidity 0 95 non condensive 4 Warmup time 30 Sec Enclosure 1 Mounting Panel mounting 2 Position Panel 3 Enclosure 125 W X 275 L X 210 H
4. password press enter If user enters correct password the controller enters Function mode after entering Function mode settings can be viewed by going on pressing the Function key The default password for the unit is 5 Note Over Load fault trip time is applicable as per Inverse trip time curve Sr Parameter Disp Def Min Max Unit No Name msg value Limit Limit 1 Under Uu 330 0 380 Vv Voltage 2 Over ou 460 410 550 V Voltage 5 Voltage Ub 60 0 100 V Unbalance 4 Current Cub 50 0 100 OL Unbalance 5 Reverse rP yes no yes NA Phase 6 Under Load UL 4 00 0 00 10 0 A 7 Over Load oL 12 00 5 0 25 0 A 8 Under Uutr 4 1 10 Sec Voltage trip time 9 Over outr 2 1 5 Sec Voltage trip time 10 SPP Trip SPtr 2 1 5 Sec Time 11 Unbalance Ubtr 2 1 5 Sec trip time 12 Under Load ULtr 60 1 90 Sec trip time 13 It Iter yes No yes NA characteristi c 14 Relay ON rLon 10 5 300 Sec time 15 Auto Reset rSt yes No yes NA selection 16 GSM Enable Gsm no no yes NA Terminal Layout 3P 415V 50Hz AC SUPPLY PROTON POWER CONTROL PVT LTD S NO 28 JAGTAP DAIRY PIMPLE NILAKH PUNE 411027 TEL 020 2727 0800 27276777 TEL FAX 020 2727 0100 MOBILE 9764885010 9422009655 E MAIL rdpawar protonpowercontrol com accounts protonpowercontrol com
5. rovides fault indication by blinking red led s for over under voltage over under load single phasing unbalance amp phase reverse User can view the parameters in Run mode display and can Hold any Run mode parameter by pressing increment key in RUN mode In Overload condition when Iter is selected as NO then it will take 2sec settable to trip Relay amp if selected as yes then the relay will Trip as following condition of set point Trip time sec 110 40 120 20 130 15 140 10 150 8 200 3 300 2 400 1 E g If Overload set point is 8A amp actual current is 9 6A then it will take 20sec 120 to trip Relay NOTE The under load and Over load faults will not sense until the feedback input is received i e contact gets closed GSM Control The GSM control can be enabled or disabled using the programming menu If the GSM control is enabled the motor will start if START sms is received by the controller The motor stops if any fault occurs or STOP sms is received by the controller If any fault occurs the controller will send an sms which contains current fault status to 3 mobile numbers stored in the controller The control sms are as explained below Sr SMS Function No START Starts the motor STOP Stops the motor STATUS Replies the present status of the controller to the sender REG Registers the number inside the controller NUMI1 phonebook wet ELE