RT-500-M Manpack User Manual

image

Contents

1. Page 16 of 16
2. DCU holder Dimensions w d h 330 x 370 x 340mm without DCU Weight 1 260 g without DCU Carrying frame Dimensions w d h 335 x 210x550 without AU Weight 2 60g without AU and battery pack DCU and AU For technical data of the DCU and the AU please refer to the RHOTHETA User Manual Installation and Operating RT 500 M Heference Page 15 of 16 RHOTHETA User Manual Manpack for RHOTHETA RT 500 M 7 Appendix T 1 List of abbreviation Meanin AU Antenna Unit CP SS Cospas Sarsat DCU Display amp Control Unit DF Direction finder Deg Degree 60 ELT Emergency Locator Transmitter GND Ground GPS 92 Global Positoning System RENE ID dentification Ingress Protection rating 1 67 LAN LocalArea Network LCD Liquid Crystal Display LED Light Emitting Diode MOB Man Over Board MSSI 1 Maritime Mobile Service Identit Ships en No Audio Frequency 0183 National Marine Electronics Association Interface and data telegram standard PLB Personal Locator Beacon PS RAM Averaging Random Access Memory PTT SBS Push To Talk Self Bearing Suppression RAM Random Access Memory Rx Receiver S N Signal to Noise SAR Search And Rescue Signal to Noise Ratio SQL Squelch TFT Thin Film Transistor see also LCD Tx Transmitter VDC Volts of Direct Current VTS Vessel Traffic Service
3. 14 TECHNICAL Dala een 15 7 aet 16 7A 16 List of figures Fig 1 Overview Of COMPONENTS E e E He EN eisai eid 6 Page 3 of 16 RHOTHETA User Manual Manpack for RHOTHETA RT 500 M 1 Designated Use Warnings and Precautions 1 1 Designated Use The Manpack is an accessory for the RHOTHETA RT 500 M Wideband Precision Direction Finder System The Manpack is designed for mounting the RHOTHETA RT 500 M Wideband Precision Direction Finder System on a portable carrying frame allowing to use the system on search and Rescue Operations which are conducted by foot 1 2 Warnings and Precautions The product contains a rechargeable battery The battery is recyclable At the end of its life under various state and local laws it may be illegal to dispose of N this battery into the municipal waste stream Dispose of the battery pack only at approved disposal sites AN Do not dispose of batteries in a fire They may explode Danger of explosion or fire if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer to avoid the risk of fire or explosion resulting in personal injury Do not use the battery pack combination with other types of battery packs battery packs with different capacities or brands Do not use or leave the battery pack near
4. ER Page 5 of 16 RHOTHETA User Manual Manpack for RHOTHETA RT 500 M 2 Overview Fig 1 Overview of components Page 6 of 16 RHOTHETA User Manual Manpack for RHOTHETA RT 500 M Description of Components Position 10 17 12 13 14 15 16 17 Description Carrying frame DCU holder Battery pack AU holder Locking lever Quickpin for locking lever Speaker Tilting axis Bag for battery pack Connector for battery pack Fuse holder AU connector DCU connector for Power Supply and Audio DCU connector for AU Jack socket for headohones Lock pin for DCU Screw driver for fastening the DCU connectors Page 7 of 16 RHOTHETA User Manual Manpack for RHOTHETA RT 500 M 3 Set up and operation of the Manpack Slide the battery pack into the bag for the battery pack The connector of the battery pack should be located at the side with the opening of the bag Pull the strap to close the bag Connect the battery pack with the connector for the battery pack Note When the Manpack is not in use the battery pack should be disconnected to avoid discharge Remove the dust cap from the AU connector Fix the dust cap at the side of the AU foot Page 8 of 16 RHOTHETA User Manual Manpack for RHOTHETA RT 500 M slide the AU into the AU holder under the tilting axis A Click is heard when the AU foot is fully engaged under the tilting axis Rotate the AU vertical Close the locking lev
5. User Manual Installation and Operating Manpack For RHOTHETA RT 500 M Wideband Precision Direction Finder RHOTHETA Elektronik GmbH RHOTHETA User Manual Manpack for RHOTHETA RT 500 M Edited by RHOTHETA Elektronik GmbH Kemmelpark Dr Ingeborg Haeckel Str 2 82418 Murnau Germany Tel 49 8841 4879 0 Fax 49 8841 4879 15 Internet www rhotheta de E Mail email rhotheta de Issue 2013 09 19 Rev 1 01 Document ID 12 9 1 0007 3 1 61 Copyright RHOTHETA Elektronik GmbH All rights reserved Note The manufacturer reserves the right to make modifications at any time and without previous information of the here described product Page 2 of 16 RHOTHETA User Manual Manpack for RHOTHETA RT 500 M Content 1 Designated Use Warnings and Precautions eene eee 4 1 1 Designated Use e RHP S 4 1 2 Marnings angdulreecaultlor15 5 60 hacobssidunens eu usas adeo react Dus v Pec epu opea oa du 4 2 Weeps dees Sums deania ance aE 6 3 Set up and operation of the nnne 8 A CHANGING ri eet 13 5 Cnarging Ine gt teda nx caue Dua rusa
6. ed at the 3 Way Outlet Shape of the connecting cable The Manpack ready to use Page 12 of 16 RHOTHETA User Manual Manpack for RHOTHETA RT 500 M 4 Changing the fuse Open screw on the fuse holder in the DCU power cable Replace the 1 6 A slow micro fuse and close the fuse holder Take care of the O Ring Page 13 of 16 RHOTHETA User Manual Manpack for RHOTHETA RT 500 M 5 Charging the Battery pack Read the documentation supplied with the battery charger This document provides information about charging and precautions for use Use only the charger that came with your Manpack to recharge the batteries Charging with a different battery charger could result in extremely high current and voltage abnormal chemical reactions may occur possibly leading the battery pack to leak overheat emit smoke burst and or ignite Do not recharge the battery pack near a heat source or in extremely hot weather Hot temperatures can inhibit recharging or can damage the battery pack Heat can possibly lead to leakage overheating smoking bursting and or igniting Page 14 of 16 RHOTHETA User Manual Manpack for RHOTHETA RT 500 M 6 Technical Data Battery pack Battery type NiMH Sub C Akku Powerpack 24V 4200mAh Battery life gt 4 hours typical Operating temperature 20 C to 40 C Charging temperature 10 C to 30 C ambient temperature Dimensions w d h 250 x 50 x 50 mm Weight 1 360 g
7. er and secure the locking lever with the quickpin Connect the AU connector with the AU Fasten the locking screw of the connector to prevent loosening and to secure water tightness Page 9 of 16 RHOTHETA User Manual Manpack for RHOTHETA RT 500 M Put on the carrying frame together with the mounted AU Adjust the shoulder straps and the waist belt so that the weight of the carrying frame and the AU is uniformly distributed When set up properly the AU should stand upright and there should not be a lot of movement of the AU when walking or hiking Hook up the DCU holder on the hooks located on the shoulder straps Connect the buckles of the DCU holder and the waist belt Adjust the straps of the DCU holder Page 10 of 16 RHOTHETA User Manual Manpack for RHOTHETA RT 500 M Slide the DCU into the DCU holder directed with the display to the chest Pull the Lock pin to arrest the DCU Connect the D SUB DCU connector for AU with the DCU Fasten the locking screws of the D SUB connector with the enclosed screw driver to prevent loosening and to secure watertightness of the connector Page 11 of 16 RHOTHETA User Manual Manpack for RHOTHETA RT 500 M Connect the D SUB DCU connector for Power Supply and Audio with the DCU Fasten the locking screws of the D SUB connector to prevent loosening and to secure watertightness of the connector Optional Connect headphones with the jack socket locat
8. heat source Heat can melt the N insulation and damage other components of the battery pack possibly leading it to leak overheat emit smoke burst and or ignite Do not immerse the battery pack in water or other liquids It can be damaged short circuited possibly leading it to leak overheat emit smoke burst and or ignite Do not disassemble or modify the battery pack If disassembled or modified the battery pack could leak overheat emit smoke burst and or ignite Do not connect the positive and negative terminals with a metal object AN such as wire Short circuiting may occur leading the battery pack to leak 7 overheat emit smoke burst and or ignite Page 4 of 16 RHOTHETA User Manual Manpack for RHOTHETA RT 500 M Do not pierce the battery pack with a sharp object mechanically deform it step on it or throw it These actions could damage or deform it internal short circuiting can occur possibly leading it to leak overheat emit smoke burst and or ignite Do not use a deformed or damaged battery pack It may leak overheat emit smoke burst and or ignite lf the battery pack leaks gives off a bad odor generates heat becomes N discolored or deformed or in any way appears abnormal during use recharging or storage immediately remove it from the Manpack or charger and stop using it N Battery electrolytes are corrosive CAN CAUSE DAMAGE TO THE EYES AND SKIN AND MAY BE TOXIC IF SWALLOWED DANG

Download Pdf Manuals

image

Related Search

Related Contents

Smart TT-4130  Tandberg Data SLR75 Internal XE Kit  Kenroy Home 10013BRL Use and Care Manual  Manuale - Gesint Srl  Modem Hotwire ReachDSL 6350 Instructions d`installation  Sharp LC-32PD5X Car Video System User Manual  Haier HWM6802 User's Manual  Dale Tiffany TA10897 Instructions / Assembly  CH-463E    