AxiCat User Manual

image

Contents

1. The I O interface K2 has the capability to work at two different voltage levels 3 3 V and 5 V The setting of the jumper JP1 determines the voltage level The picture above shows the jumper setting for 5 V operation If you remove the jumper the USB function will enumerate when you plug in the AxiCat but the I O interface will be non operational IMPORTANT Always check the position of the jumper JP1 before you power up the AxiCat Be sure the selected voltage matches the voltage level of the hardware that s attached to the I O interface The jumper must be set into position only when the AxiCat is powered off If you change the jumper while the AxiCat is powered on the result will be unpredictable and you may destroy hardware that s connected to the board When attaching hardware to the AxiCat it s important to understand how the power lanes are routed between the board s various pins The picture above uses colored squares to denote the wiring of the pins Ground gray All ground pins are wired together including the ground line of the USB cable 5 V red The 5 V comes from the USB cable and is distributed to all 5 V pins 3 3 V orange This voltage is derived from the 5 V supply and distributed to all 3 3 V pins I O V yellow The I O voltage lane is wired to either the 3 3 V or 5 V by means of the jumper JP1 All I O pins K2 and the reset input operate at this
2. IOD OB O Set SPU GPIO11 as output IOW OB 1 Set SPU GPIO11 high OME Enable the 1 Wire master Since there s only one 1 Wire slave present on the bus we can use the Skip ROM command Let s check the power mode of the DS18B20 Command OMR 1 Wire reset Response OMR1 Presence of 1 Wire slave detected Command OMT CC B4 Skip ROM Read Power Supply Response 4 Command OMB 1 Read a bit DS18B20 reports a zero bit parasite Response 0 P power mode The DS18B20 reports parasite power mode That s correct since we ve wired the User Manual 25 AxiCat DS18B20 s power line to ground Start a temperature conversion and enable strong pull up Command OMR 1 Wire reset Response OMR1 Presence of 1 Wire slave detected Skip ROM gt Convert Temperature mman 44 S ios ang enable strong pull up Response OMTCC44 The LED will light up The DS18B20 needs about 750 ms to convert the temperature After that we can read the results from the tempearature sensor Command OMR 1 Wire reset Response OMR1 Presence of 1 Wire slave detected Command CC BE FFFFFFFFFFFFFFFFFF Skip ROM Read Scratchpad Response OMTCCBEFF074B467FFF01102F Scratchpad data 8 bytes and CRC The DS18B20 returns 9 bytes the last data byte being the CRC The first two bytes are the 16 bit temperature register LSB first The register s val
3. AxiCat 1 Features Multipurpose I O card with USB interface Powerful 12 MHz ATmegal64A 324A 6444 1284 microcontroller Selectable 3 3 V and 5 V I O voltage levels 17 bidirectional general purpose I O pins with programmable pull up 2 fully independent serial ports SPI bus master function 4 slave select lines 2 bus with pull up resistors master and slave function support for repeated start arbitration clock stretching device probing 1 Wire bus master function strong pull up control accelerated enumeration and probing of 1 Wire slaves Truly asynchronous design enables all interfaces to operate concurrently while executing I O commands back to back avoiding inter command delays USB bus powered Support for USB remote wake up Can be used as general purpose development board for Atmega164A 324A 644A 1284 microcontrollers Integrated bootloader and accompany ing software for Linux and Windows enable easy upgrading of firmware and development of own software Four mounting holes Prototyping of I2C slave functions Educational platform for learning and teaching I2C Allows you to connect AbioCard AbioWire and other boards to a PC AxiCat server program enables network and local access using an easy protocol Use Python PHP C or other languages to program the 4 User Manual AxiCat 2 Technical Specific
4. Slave Disabled Function Disabled Address 0000000b Baud rate 115200 Data bits General call Disabled SPI Stop bits Function Disabled Rx timeout Pin Groups Speed DQ SPU GPIO11 1 Wire pins ground ground TXDO e RXDO UARTO pins TXD1 RXD1 UART1 pins User Manual 750000 Hz 5 5 ground ground ground Power supply SDA SCL TWI pins Speed GPIO8 GPIO9 GPIO10 GPIO11 GPIO12 GPIO13 GPIO14 GPIO15 GPIO16 Standard EH HEN Bee SS3 GPIO2 SS2 GPIO5 SS0 SS1 GPIO7 AxiCat Microcontroller AxiCat s design incorporates a microcontroller from the ATMEL 164 324 644A 1284 family These chips are pin compatible and offer different sizes in Flash memory EPPROM and SRAM The microcontroller is clocked at 12 MHz A standard AxiCat is issued with ATmega164A microcontroller This processor is more than capable of providing all functionality offered in the standard version It s possible to develop and deploy your own software for the AxiCat Whe
5. abiocardserver axicat dev ttyUSBO p 5678 amp abiocardserver axicat dev ttyUSBl p 5679 amp Running the equivalent server instances in Windows may look like this gt abiocardserver exe axicat COM4 p 5678 gt abiocardserver exe axicat COM5 p 5679 1 Wire Automation Server The 1 Wire Automation Server supports special functions 1 Wire UARTO UART1 and TWI You can connect 1 Wire slaves directly to the 1 Wire bus You can hook up a variety of 1 Wire adapters with an I2C or serial interface Its possible to connect multiple 1 Wire adapters to a single AxiCat For example you could connect HA7S to UARTO another HA7S to UART set of DS2482 chips to the I2C bus and a couple of DS18B20 temperature sensors to the 1 Wire bus Just make sure that all connected components operate at the same voltage level 16 User Manual AxiCat 5 Application Examples Connecting Things The AxiCat is very well suited for connected and exploring an endless variety of hardware ranging from simple I O to a complex synergy of all special functions This section contains a number of examples to start with Each example highlights a specific subset of the functionality You can combine the various special functions and features to create powerful solutions GPIO Each GPIO pin can be set as output or input Each output buffer has symmetrical drive characteristics with both high sink output low and source output high
6. axicatserver s dev ttyUSB1 p 4001 crlf 6 Likewise in Windows axicatserver s COM10 p 4000 crlf 4 axicatserver s COM11 p 4001 crlf 4 First things first Let s set up the I2C function in master and slave The I2C slave is assigned address 20h AxiCat 1 Master Command IMS S 50000 Set bus speed to 50000 Hz Command Enable I2C master Enable I2C master Enable slave address 20h no GCA general call address Let s starts off with a simple example The slave is programmed to return four characters ABCD when the I2C master reads from SLA R the slave AxiCat 2 Slave The L is important If says the entire payload is specified AxiCat 1 Master Command IMT 41 0004 Read 4 bytes from address 20h Response IMT41A41424344 Response The master reads four bytes from the slave The response tells us that the slave acknowledged address 20h and four characters ABCD were transmitted At this point the I2C slave Tx transfer completes 22 User Manual AxiCat AxiCat 2 Slave This response indicates four bytes were transferred and the master signaled NACK after the last byte was transmitted This is correct What if the master reads a different amount of data bytes In case the master reads less bytes the slave will get a response like ISWOO002A only 2 bytes were transmitted If the master reads more bytes the slave will pad the payload with FFh bytes the
7. microcontroller The bootloader offers several features You can upgrade to the latest version of the main application As a maker you can develop your own main application and use the bootloader to download and run your software in the AxiCat It provides information about your AxiCat It works together with the free aximcubldr software 10 User Manual AxiCat The bootloader is the first piece of software that s executed when the AxiCat is powered up As soon as the bootloader is started it checks the connection of the pads labeled JP2 BOOTLDR When the pads are open the bootloader hands over control to the main application which offers the main features of the AxiCat This is the normal intended operation of the board When the pads are closed the bootloader remains active It takes over the USB interface and as such the associated serial port in your operating system communicates with the bootloader instead of the main application To activate the bootloader follow these steps 1 Close the pads labeled JP2 BOOTLDR You can use a male male jumper wire or similar 2 If the board is powered up reset the firmware else connect the board to the USB bus to power it up Once the bootloader is activated you can use the aximcubldr program to communicate with the bootloader from the computer the AxiCat is plugged into The program can examine the bootloader write HEX object files into flash memory and EEPROM of th
8. system Linux Serial ports are accessible in the device directory structure A serial path starts with dev A serial path is case sensitive The following table summarizes serial paths that are commonly found on Linux systems Serial Path Serial Port dev ttySO The computer s 15 on board serial port dev ttyS1 The computer s 274 on board serial port dev ttyS2 The computer s 3 on board serial port dev ttyS3 The computer s 4 on board serial port dev ttyUSBO 15 USB serial adapter dev ttyUSB1 274 USB serial adapter dev serial by id This directory contains symbolic links to serial devices Each symbolic link name identifies a specific device dev serial by path This directory contains symbolic links to serial devices Each symbolic link name represents a hardware path to the device like a specific USB port on your computer Here are some useful commands you can run to get information about present serial devices and their corresponding serial path The following commands were run on a Linux system with one on board UART and one connected USB serial adapter Filter information from the kernel message buffer 5 dmesg grep tty 000000 console tty0 enabled 516785 serial8250 ttySO at I O 0x3f8 irq 4 is a 16550A 517463 00 0b ttySO at I O Ox3f8 irq 4 is a 16550 559097 tty tty55 hash matches 076326 usb 2 1 FTDI USB Serial Device converter now attached to ttyUS
9. 1 Wire slaves offer parasite power mode and need an external 5 V power supply instead You can use the 5V line of the AxiCat If you connect many 1 Wire slaves you ll hit the power limit of the AxiCat at some point In that case you can resort to deploying a 1 Wire power injector Here s how to enumerate the 1 Wire slave device s connected to the HA7S Command 905 D 8 Set 8 data bits Command 0908 S 1 Set 1 stop bit Command UOS B 9600 Set 9600 baud Command UOE Enable UART UOW 53 Transmit SEARCH ROM command to HA7S Tx data S Command UOR 0020 Read data from UART UARTO received 17 10h 1 data bytes Command U0R42313030303830324134 Response 3941313731300D Rx data B1000802A49A1710 CR HA7S reports ROM code 10 000802A49A17 B1 Transmit NEXT SEARCH ROM command to mman UOW 7 Co a d 0 3 HA7S Tx data Command UOR 0020 Read data from UART UARTO received 1 00h 1 data byte Rx data CR empty string Response UOROD The table shows an enumeration of one 1 Wire slave If your setup includes additional 1 Wire slaves then you can repeat the s command to retrieve the ROM codes of all 1 Wire slaves Here s another enumeration with two 1 Wire slave devices connected to the HA7S This time unsolicited responses are enabled meaning the server automatically sends UART Rx data to the client Command 908 D 8 Set 8 data bits Comma
10. capability Each input has a selectable pull up resistor with a supply voltage invariant resistance An input without active pull up resistor behaves as tri state All GPIO pins have protection diodes to ground and Vcc Please refer to the Atmega164A 324A 644A 1284 datasheet for more information The following example demonstrates the capabilities of the GPIO pins It s assumed that program axicatserver is connected to the AxiCat in the example setup The setup uses GPIOS5 as a sinking output GPIO6 as a sourcing output and GPIO7 as input with active pull up First you ve to initialize the GPIO pins Send the following commands to the server IOD 05 O Set 5 as output IOD 06 O Set GPIO6 as output IOD 07 1 Set GPIO7 as input IOW 07 1 Activate pull up on GPIO7 Let s drive GPIO5 Set the output low logic 0 to sink current and turn on the LED Set high logic 1 to turn off the LED User Manual 17 AxiCat Command IOW 05 0 Turn LED on GPIO5 Command 10 05 1 Turn off LED on 5 GPIO6 is used as sourcing output Set the output high logic 1 to source current and turn on the LED Set the output low logic 0 to turn off the LED Command IOW 06 0 Turn off LED on GPIO6 Command IOW 06 1 Turn on LED on GPIO6 A switch controls the input state of GPIO7 When the switch is closed the input is pulled to ground When left open the active pull up pulled the input to Vcc Com
11. present the response would be IMTDOOOOON None of the registers are in a defined state after the DS1307 has powered up Initialization is required The following 2 SLA W transfer programs a time and date sets 24 hour mode and instructs the real time clock to start running CH 0 20 User Manual AxiCat Transmit 9 data bytes register OOh followed by eight bytes 0 00 seconds 00 minutes 00 hours 24 hour mode day 1 date 01 month 01 year 00 RS 1 0 00b 5 0 OUT 0 All data bytes were transmitted IMT DO 00 00 00 00 O1 01 01 00 00 Response IMTD00009A In order to read out the time and date you ve to write SLA W the index of the first register to access and read SLA R the time and date registers IMT DO 00 IMTD00001A IMT D1 0007 IMTD1A56160001010100 Command Write index of register to access Response One byte written to the slave Command Read seven bytes Response The master received seven data bytes The last response contains the time and date These values will be different each time you read them out You can send the two I2C transfers at once Add R to the first command doing so also ensures the second I2C transfer starts with a REPEATED START signal Command IMT DO 00 R Write index of register to access Command IMT D1 0007 Read seven bytes Response IMTD00001A One byte written to the slave Response IMTD1
12. response will be ISWOOO4A Anyway the response to the slave Tx transfer will contain which indicates the master read a different number of bytes than the slave provided Now let s pull SCL low Proceed as follows AxiCat 1 Master The LED lights up The reason is that the I2C slave has been addressed successfully SLA R but there s no data available to transmit hence the slave pulls SCL low 2 bus is now totally locked up AxiCat 2 Slave Command ISW 41 42 43 44 L Data bytes to write full payload Response ISW0004N Four data bytes transmitted AxiCat 1 Master Response IMT41A41424344 Response As soon as we send the I2C slave Tx command the I2C bus transfer between master and slave continues the LED darkens and responses come back The I2C bus becomes idle again User Manual 23 AxiCat SPI Master The following example shows how to use the SPI master function with an EEPROM chip We ve picked the Microchip 25LCO20A as the SPI slave This EEPROM chip has a memory space of 256 bytes AxiCat The circuit operates at 3 3 V a Vcc range of 2 5 5 5 V You can also make it work at 5 V the SPI EEPROM chip has Its assumed that program axicatserver is connected to the AxiCat in the example setup Initialization for this circuit requires setting up SS2 GPIO5 and enabling the SPI master IOD 05 O Set SS2 GPIO5 as output IOW 05 1 Set SS2 GPIO5 high Yo
13. voltage User Manual 7 AxiCat I O Interface The I O interface K2 consists of 26 pins The pin numbering is shown in the left picture Pin number one is marked as a reference in various illustrations 3 3 V GPIO8 GPIO9 GPIO10 ground GPIO 11 GPIO12 GPIO13 3 3V GPIO14 GPIO15 GPIO16 ground 5V 3 3V 5V 5V SDA 5V ground SCL ground GPIOO DQ TXDO GPIO1 ground RXDO GPIO2 SPU GPIO11 SS3 GPIO2 ground GPIO12 ground GPIO3 GPIO13 TXD1 GPIO4 3 3 V RXD1 ground MOSI ground 5 MISO SS2 GPIO5 GPIO6 SCLK SS0 GPIO7 ground SS1 GPIO7 JERR LOE All special functions disabled All special functions enabled Seventeen pins are digital general purpose input output GPIO pins Each GPIO pin can be individually programmed as input or output A pull up resistor can be enabled and disabled for each input pin All GPIO pins operate at the voltage level selected on JP1 Note that GPIO8 and 9 are hardwired to 4 7 KQ pull up resistors on the AxiCat board These pins are part of the I2C bus which requires pull up resistors Besides the GPIO pins the I O interface offers four special functions UARTO UART1 TWI and SPI Each special function can be individually enabled and disabled When a special function is enable
14. who are used to working with similar third party Python modules AxiCat Command Line Tool This program talks directly with the AxiCat at the level of the serial interface This is the lowest level of communication possible and is defined as the AxiCat serial protocol The program applies the serial protocol in a very simple and minimalistic way It takes user commands and translates them into command packets that are sent to the AxiCat A number of user commands read back data bytes from the AxiCat Other user commands provide features such as reading data bytes from the AxiCat and waiting for a certain amount of milliseconds For more information please read the AxiCat Command Line Tool user manual The manual is available for download on the Axiris website 14 User Manual AxiCat AxiCat Application Layer The AxiCat Application Layer AL logically sits on top of the AxiCat serial protocol It s a software module that implements the complete serial protocol and offers a non blocking API to the upper layer Thanks to its non blocking design the module offers high performance for all available I O You can easily schedule multiple transfers for GPIO 2 SPI 1 Wire and UARTs concurrently the module will efficiently handle all transfers with the AxiCat and report completion when ready The AxiCat AL is available as C source code so you can incorporate the module into your own software that uses the AxiCat The source of pro
15. A56160001010100 The master received seven data bytes TWI Slave The slave functionality is quite elaborate The following example explores the basics of TWI slave function We ve chosen a second AxiCat to act as the I2C master You can use another I2C master instead as long as it is able to detect clock stretching and act accordingly AxiCat 1 Master User Manual AxiCat 2 21 AxiCat An I2C slave has the ability to pull SCL low The slave literally freezes the I2C bus as no activity will occur as long as SCL is pulled low This mechanism allows the 2 slave to buy some time when it can t respond to a master immediately For this example we ve wired a LED to the clock line The LED will light up when SCL is low During normal I2C bus activity you may see the LED flicker briefly When the slave pulls down SCL for a long period the LED lights up clearly Normally one doesn t connect a LED to the SCL line The capacitance of the LED may bring down the maximum bus speed so we use a speed setting of 50 kHz to be on the safe side It s assumed that an instance of program axicatserver is connected to each AxiCat in the example setup Each instance has to use a different port number Here s how to set up two servers in network mode for use with a terminal program parameter crlf is usually specified for use with terminal programs Example in Linux axicatserver s dev ttyUSBO 4000 crlf 6
16. AxiCat Multipurpose I O Card User Manual December 2014 AxiCat Table of Contents 1 Features 4 2 Technical Specifications 5 3 AxiCat 6 Board Overview 6 USB Interface 6 Power Configuration 7 I O Interface 8 Initial Values 9 Pin Groups 9 Microcontroller 10 Firmware Reset 10 Main Application 10 Bootloader 10 4 Software Support 12 The Big Picture 12 AxiCat Server 13 AxiCat Client for Python 14 AxiCat Command Line Tool 14 AxiCat Application Layer 15 MCU Bootloader Tool 15 AbioCard GUI 15 AbioCard Server 15 1 Wire Automation Server 16 5 Application Examples 17 Connecting Things 17 GPIO 17 UART 18 TWI Master 20 TWI Slave 21 SPI Master 24 1 Wire Master 25 Deploying as Development Board 27 Connecting an AbioCard to any Supported Computer 28 Connecting an AbioWire to any Supported Computer 29 2 Multi Master Arbitration Test Setup 30 6 Serial Paths 32 Linux 32 2 User Manual AxiCat Windows 7 Legal Information Disclaimer Trademarks 8 Contact Information Revision History Date Authors 34 34 34 34 Description 2014 07 11 Peter S heeren Initial release 2014 09 05 Peter S heeren Updated software section Updated application examples for use with AxiCat server Second release 2014 09 17 Peter S heeren Added 1 Wire Third release 2014 09 28 Peter S heeren Fourth release 2014 12 12 User Manual Peter S heeren Fifth release
17. BO Use the setserial command to produce a list of serial paths setserial g dev ttyS dev ttyUSB dev ttyS0 UART 16550A Port 0 03 8 IRQ 4 dev ttyS1 UART unknown Port 0x02f8 IRQ 3 dev ttyS2 UART unknown Port 0x03e8 IRQ 4 dev ttyS3 UART unknown Port 0x02e8 IRQ 3 dev ttyUSBO UART unknown Port 0 0000 IRQ 0 Flags low latency 32 User Manual AxiCat List serial devices in the device directory 5 15 1 dev ttyS dev ttyUSB crw rw 1 root dialout 64 2012 02 22 19 dev ttySO crw rw 1 root dialout 65 2012 02 22 19 dev ttyS1 crw rw 1 root dialout 66 2012 02 22 19 dev ttyS2 crw rw 1 root dialout 67 2012 02 22 19 dev ttyS3 crw rw 1 root dialout 188 0 2012 02 22 20 dev ttyUSBO Windows Serial ports are accessible through the Win32 device namespace which is part of the NT namespace As such a serial path starts with followed by the device name of the serial port A serial path is case insensitive A serial port is typically named COM lt x gt where x is a number between 1 and 256 Other naming schemes may apply and aliases may exist depending on the serial driver that controls the serial port You can obtain a list of available serial ports 01 x in the device manager Open the device Acton wew manager and view devices by type The 7 8 amp 2 25 section named Ports COM amp LPT contains all 8 99 Monit
18. Manual 27 AxiCat Connecting an AbioCard to any Supported Computer With the help of the AxiCat you can connect an AbioCard model A or B to any computer that s capable of running the AbioCard software Make sure the jumper JP1 is set to 3 3 V operation as shown in the picture above The following is an example of the abiocardgui program running in Linux and talking with an AbioCard model B mounted on an AxiCat Linux has assigned serial path dev ttyUSBO to the board Axiris AbioCard v1 4 0 4 AxiCat dev ttyUSBO Connect Connected to AbioCard PWM PWM2 Prescaler 20 290 6 Hz DIRECTION 8 1 00000 1 I 0 Ro o READ 8 1 5 12 0 1000 ot WRITE 8 1 Ti 1000 1400 01 FJ 2400 2800 o 2014 06 03 22 07 40 C 1000 ot 2014 06 03 22 07 40 Auto 154 3100 1600 o Battery low 111610 2310 O hes 60 o 4 1225 1050 ot 4 1330 1155 01 1 1065 2835 ot 7 3780 3780 o 10 p ot FJ 700 2695 o LT me 265 28 User Manual AxiCat Connecting AbioWire to any Supported Computer Thanks to the AxiCat you can attach an AbioWire board to any computer that s gt capable of running the 1 Wire Automation Server software dedicated enclosure for the AxiCat with AbioWire combo is available The acrylic enclosur
19. and responses allows for very simple processing in your language of choice The following example shows how to use the AxiCat from a Python program User Manual 13 AxiCat import axicatclient Connect to the AxiCat Server client axicatclient AxicatClient localhost 4000 Set GPIO 1 as input high state meaning pull up activated client gpioSetDir 1 client GPIO DIR INPUT client gpioWrite 1 1 Read input state of GPIO 1 state client gpioRead 1 print GPIO 1 input state i state Save this file as client py for example You can run the program in Linux as follows python client py GPIO 1 input state 1 The output shows that the Python program successfully connected to the server sent the GPIO read command and received the response containing the state of GPIO pin 1 For more information please read the AxiCat Server user manual The manual is available for download on the Axiris website AxiCat Client for Python This module is written in Python It enables Python programs to communicate with the AxiCat Server as a network client The previous section contains an example Python program that uses the module The module offers a blocking API Since the AxiCat Server defines an asynchronous communications protocol the Python module can t offer the full functionality of the server On the other hand the blocking API of the Python module is very easy to use and looks familiar to programmers
20. ations Weight 12g Dimensions 56 mm x 40 mm x 12 mm WxDxH User Manual AxiCat 3 AxiCat Board Overview lt l on 1006 c 12 oe 9 Dy epe ot f SIN Label Description BOOTLDR Close pads to activate bootloader on reset power up JP2 K1 USB Mini B receptacle JP1 Jumper for selecting between 3 3 V and 5 V on K2 RESET Close pins to force a firmware reset K2 Header that exposes the various I O interfaces USB Interface The AxiCat incorporates an FTDI FT245 USB to FIFO chip Once enumerated the USB function will appear as a serial port in your operating system The operating system assigns a serial path to the serial port The board is USB bus powered The maximum current provided by a USB port is 500 mA The AxiCat has a polyfuse that limits the current usage to 350 mA The AxiCat supports USB remote wake up This means the device can wake the USB function and possibly the entire system when certain events occur on the I O interface like the arrival of data on one of the UARTs 6 User Manual AxiCat Power Configuration 3 3 V ground ground 1 3 3 V I O V I O V I O V ground 5V 5V ground V V ground V ground V V V BI I e BE 5 e IS E DIDO N
21. d it overrides a group of GPIO pins Most GPIO pins share a special function All special functions operate at the voltage level selected on JP1 UARTO and UART1 provide a serial bus with full duplex operation The UARTs operate completely independent Supported features include 5 9 data bits 1 2 stop bits standard baud rates up to 115200 baud and raw speed setting The Two Wire Interface TWI implements a full fledged I2C bus Master and slave operations are possible Features include repeated start clock stretching multi master arbitration standard speeds of 100 kHz and 400 kHz and raw speed setting The Serial Peripheral Interface SPI implements a three wire synchronous serial bus with master operation and four slave select lines Note that three of the SPI slave select lines SS1 SS2 and SS3 do not override the functionality of the GPIO pins You can use any of these lines as GPIO as long as you don t specify them in an SPI command If you plan to use one or more of these slave select line for SPI you have to initialize the corresponding GPIO pins to output and logic one before sending SPI commands 1 Wire interface provides a 1 Wire bus with master operation and optional control for an external strong pull up 8 User Manual AxiCat Initial Values GPIO O 16 TWI Direction Input Function Disabled Function Disabled State Pull up active logic 1 UART O 1 Speed 100 kHz
22. e microcontroller and run the firmware application right away User Manual 11 AxiCat 4 Software Support The Big Picture Software support for AxiCat is quite elaborate The versatile nature of the AxiCat has lead to the creation of various software components The following picture gives an overview of the relationship between the software components Bootloader Tool Supporting software Network stdio 1 Wire Automation Websites Programming Server languages Interactive PHP Automation Python C C All software runs on Linux and Windows operating systems This way the end user is given a great deal of flexibility and choice of computer systems and configurations when deploying the AxiCat Source code of the parts marked in yellow is available 12 User Manual AxiCat AxiCat Server This program is an important tool for working with the AxiCat It s usually run as a server process hence the name It offers the functionality of the AxiCat Application Layer as a server The server offers two modes of communication with the AxiCat Network mode a socket interface enables communication over the network Standard input and output mode another process communicates with the AxiCat by means of redirecting its input and output to the AxiCat server The server uses a simple communications protocol that is both human readable and easy to format and parse programmatically Com
23. e allows you to set up the hardware for ease of use The AbioWire is a 3 3 V device Make sure the jumper JP1 on the AxiCat is set to 3 3 V operation Suppose your AxiCat with AbioWire combo is plugged into a computer running Windows and the AxiCat is enumerated as serial port COM4 Feed the following commands to the 1 Wire Automation Server in order to use the AbioWire adapter aw add serial COM4 axicat twi abiowire adapter aw enable Execute the dump dn command to query the device node structure for the enabled adapter dump dn Device Nodes ROOT SERIAL COM4 open AXICAT open 1 I2CBUS twi open 3 OWS DRV DS2482 ad 18h open gt adapter awl OWS DRV DS2482 ad 19h open gt adapter awl OWS DRV DS2482 ad open gt adapter awl Likewise you can add multiple AbioWire adapters to the 1 Wire Automation Server Suppose you connect two combos to a computer with Linux and the serial ports are enumerated as ttyUSBO and ttyUSB1 The following commands will add and enable the AbioWire adapters in the 1 Wire Automation Server awl add serial dev ttyUSBO axicat twi abiowire aw2 add serial dev ttyUSB1 axicat twi abiowire awl enable aw2 enable User Manual 29 AxiCat I2C Multi Master Arbitration Test Setup Multi master arbitration is a powerful feature of the I2C bus It allows multiple masters to negotiate access to a single I2C bus It s an i
24. gram axicatserver is a good starting point for learning to develop with the module MCU Bootloader Tool Program aximcubldr vi 0 1 or later adds support for the AxiCat bootloader This tool allows you can upgrade the AxiCat with the latest version of the main application The tool also enables you to deploy the AxiCat as a general purpose development board for the family of ATmega164A 324A 644A 1284 microcontrollers AbioCard GUI The abiocardgui program starting from v1 4 0 XO adds support for the AxiCat 4 AxiCat WACOM8 With the addition of the AxiCat interface it s now Disconnected possible to interactively work with an AbioCard MINI model A or B on any computer that s supported by the AbioCard GUI program DIRECTION 8 1 O 0 READ 8 1 5 WRITE 8 1 AbioCard Server Program abiocardserver has been extended with support for AxiCat It now runs on Linux as well as Windows This means the possibilities to deploy the AbioCard with the server program have been significantly increased You can run the server to control an AxiCat with AbioCard combo on any supported Linux system like this abiocardserver axicat dev ttyUSBO p 5678 Likewise in Windows gt abiocardserver exe axicat COM4 p 5678 User Manual 15 AxiCat You can run multiple instances of the server on a single computer each server instance controlling an AxiCat with AbioCard combo For example
25. jury death property damage or environmental damage Axiris accepts no liability for inclusion or use of Axiris products in such applications and such inclusion or use is at the customer s own risk Should the customer use Axiris products for such application the customer shall indemnify and hold Axiris harmless against all claims and damages Trademarks Atmel is a registered trademark or trademark of Atmel Corporation or its subsidiaries in the US and or other countries Microchip is a registered trademark of Microchip Technology Incorporated in the U S A and other countries All product names brands and trademarks mentioned in this document are the property of their respective owners 8 Contact Information Official website http www axiris eu 34 User Manual
26. loader use the aximcubldr software to download and run your HEX object file in the AxiCat In Windows gt aximcubldr exe serial COM4 flash myimage hex run Likewise in Linux 5 aximcubldr serial dev ttyUSBO flash myimage hex run If you run the command without the flash option the bootloader jumps to the main application The image shows an example setup for developing a program that controls a HA7S 1 Wire adapter connected to UARTO on the AxiCat The entire setup works at 5 V You probably want close the pads JP2 BOOTLDR for the duration of the development of your own software You can use a male male jumper wire for this purpose It s the looped wire in the image We ve wired a push button to the reset pins Since JP2 is closed pressing the reset button will bring the AxiCat in bootloader mode This behavior is convenient for development where you usually repeat this sequence a lot reset flash run The AxiCat features two UARTs You can hook up one UART to a 3 3 V or 5 V level serial port that is connected to a computer With this setup you can transmit debug information from your own software over the serial line to the computer and print the debug information in terminal program like Putty The image shows a USB to serial adapter with 3 3 V and 5 V selectable interface wired to UART1 on the AxiCat Note that you can always put back the original AxiCat main application User
27. mand 10807 Read state of GPIO7 Input sensed state is high meaning the switch is open Command 07 Read state of GPIO7 Response 10807111 Input sensed state is low meaning 10807011 5 the switch is closed UART This section explains how to connect things to the UARTs We ve chosen a practical example that features a simple 1 Wire network It s assumed that program axicatserver is connected to the AxiCat in the example setup AxiCat 0518520 image shows 75 1 Wire adapter attached to UARTO of the AxiCat The HA7S is the small PCB sticking out of the breadboard The 1 Wire adapter uses a serial interface The serial settings are 9600 baud 8 data bits 1 stop bit The communications protocol employs a simple synchronous command response model using ASCII characters A DS18S20 1 Wire temperature sensor is wired to the HA7S The temperature sensor comes TO 92 package that resembles a transistor In this example the 0518520 is wired for parasite power mode which means it taps power from the DQ line rather than the Vcc line Parasite power mode allows one to limit the 1 Wire bus to merely two wires 18 User Manual AxiCat DQ and ground The entire setup operates at 5 V The AxiCat powers the 1 Wire adapter and temperature sensor The dotted area in the schematic indicates you can connect additional 1 Wire slaves to the 1 Wire adapter Note that not all
28. mands and responses are composed of ASCII characters Commands can be padded with spaces to enhance readability Empty lines and comments are permitted as well The latter features come in handy when you create script files You can manually send commands using a terminal program like PuTTY For example ici x Category Session Logging Terminal Keyboard Bell Features E Window Appearance Connection Date Basic options for your PUTTY session Specify the destination you want to connect to Host IP address 192 168 1 110 Connection type 6 Raw Telnet C Rlogin C SSH Seral Load save or delete a stored session Saved Sessions Default Settings Load Save Delete Close window on exit Always Never Only on clean exit About Open Cancel In the above example the server is connected to from a remote computer All it takes is the IP address and port of the server Next a number of commands are typed in to which the server responds For the curious the SPI transfer actually reads out the first 8 bytes from a Microchip 251 020 EEPROM chip The CS pin of the EEPROM is connected to 552 on the AxiCat The first four bytes had been programmed as ABCD earlier Network mode is great for controlling the AxiCat from a programming language Every popular language has built in support for programming with network sockets The format of commands
29. n the application exceeds the memory limits of the 164 AxiCat can be equipped with a more powerful microcontroller Note Axiris may deliver an AxiCat with a more powerful microcontroller at its own discretion Firmware Reset You can reset the firmware in a powered AxiCat by shorting the pins of the RESET K3 header The firmware will restart as soon as the pins are released There are several instances where you may want to reset the firmware Activate the bootloader Quickly revert the I O interface and main application to their initial state Main Application The main application implements the core functionality of the AxiCat The AxiCat is shipped with the main application preprogrammed in the flash memory of the microcontroller The main application accepts incoming command packets and issues response packets over the USB interface Command packets are translated to activities on the I O interface or other actions like setting parameters Response packets are sent when the I O interface has completed activities or status must be reported Command and response packets and their behavior are part of the AxiCat serial protocol The serial protocol is specified in a separate document For more information please read AxiCat Technical Note 001 Serial Protocol This document is available for download on the Axiris website Bootloader The AxiCat comes with a bootloader preprogrammed in the flash memory of the
30. nd U0S S 1 Set 1 stop bit Command U0S B 9600 Set 9600 baud Command U0E Enable UART 0 Command 005 0 0020 Enable unsolicited responses 32 data bytes Command UOW 53 ec eem ROM command to 75 Response 00842313030303830324134 received 17 10h 1 data bytes 3941313731300D Rx data B1000802A49A1710 CR User Manual 19 AxiCat HA7S reports ROM code 10 000802A49A17 B1 Transmit NEXT SEARCH ROM command to HA7S Tx data s UARTO received 17 10h 1 data bytes Command UOW 73 U0R43343030303030343043 4242423232380D Rx data C40000040CBBB228 CR Response HA7S reports ROM code 28 0000040CBBB2 C4 Transmit NEXT SEARCH ROM command to HA7S Tx data s Command U0W 73 UARTO received 1 00h 1 data byte Rx data CR empty string Response UOROD TWI Master The AxiCat offers an elaborate I2C master function The example presented in this section introduces the reader to the basic operations of the master We ve attached a DS1307 real time clock to an AxiCat It s assumed that program axicatserver is connected to the AxiCat in the example setup AxiCat The slave address of the DS1307 is 1101000b Let s check whether the DS1307 reacts to the slave address Command IMT DO SLA W address 68h no data bytes Response IMTD00000A The slave acknowledged SLA W The response affirms the DS1307 is present on the I2C bus Note that if the DS1307 weren t
31. nteresting subject to take a closer look at The hard part of multi master arbitration is that it may be hard to reproduce with the tools you have at hand We ve devised a test setup that allows you to easily recreate various arbitration situations The setup uses two AxiCat boards a DS1307 slave a breadboard and a bunch of jumper wires AxiCat 1 AxiCat 2 The two AxiCat devices act as I2C masters They ll try to access the DS1307 slave device while honoring the rules of arbitration GPIOO does the magic Its function is to hold low SCL to prevent the I2C masters from accessing the bus This state is also known as clock stretching While SCL is held low the masters are instructed to start a transfer They won t access the bus though When GPIOO releases SCL both masters will access the bus at the same time GPIOO must be used in a specific way First initialize to logic zero Next manipulate the direction to control the SCL line When GPIOO is set as output it holds SCL low When GPIOO is set as input the pin becomes tri state thus releasing SCL Remember that SDA and SCL are pulled upon the board hence the state of a released SCL is logic one Now run an instance of program axicatcl with each AxiCat and enter the following commands 30 User Manual AxiCat AxiCat 1 Command Protocol bytes Description io 0 0 05h 00h Set GPIOO to logic zero io 0 out 04h 80h Set GPIOO to output SCL held low twi ena Enable TWI twi star
32. ors il bl T E Network adapters available serial and parallel ports 9 Ports amp LPT Communications Port COM 1 The device name of a serial port is shown ECP Printer Port LPT 7 USB Serial Port COM3 Processors SCSI and RAID controllers Sound video and game controllers System devices Universal Serial Bus controllers between parentheses In the picture to the right you can see two serial ports 1 is the PC s on board serial port COM3 represents a USB serial adapter H A t The serial paths to the serial ports in the picture are Serial Path Serial Port COM1 Communications Port COM1 COM3 USB Serial Port COM3 Serial paths like COM1 that s without the prefix will work because COM1 to COM9 are reserved names in the NT namespace COM10 to COM256 aren t reserved names and you ll have to specify the prefix with these device names By comparison serial path COM100 will work but serial path COM100 won t work User Manual 33 AxiCat 7 Legal Information Disclaimer Axiris products are not designed authorized or warranted to be suitable for use in space nautical space military medical life critical or safety critical devices or equipment Axiris products are not designed authorized or warranted to be suitable for use in applications where failure or malfunction of an Axiris product can result in personal in
33. t 68h w DOh SLA W address 68h 2 03h twi mtx 0000 00h 00h oon 4 data bytes twi stop STOP rx No data due to SCL held low AxiCat 2 Command Protocol bytes Description twi ena 22h Enable TWI twi start 68h w 24h DOh SLA W address 68h 26h 03h twi mtx 0100 00h Olh 00h Transmit 4 data bytes twi stop 25h STOP rx No data due to SCL held low Now we re going to release the SCL line and see how the I2C master will proceed AxiCat 1 Command Protocol bytes Description io 0 in Tx 04h 00h Set GPIOO to input release SCL 24h DOh SLA W address 68h received ACK response 26h 03h 03h Transmitted all 4 data bytes 25h STOP signal generated AxiCat 2 Command Protocol bytes Description 24h DOh SLA W address 68h received ACK response 23h Arbitration lost during following command 26h 03h 01 Transmitted 2 of 4 data bytes A5h Skipped STOP The results indicate that AxiCat 1 has won the arbitration during the transmission of the second data byte Once you get the hang of it you can try out other combinations of SLA W SLA R slave address and data bytes to see how arbitration behaves User Manual 31 AxiCat 6 Serial Paths You need to specify a serial path in order to communicate with a serial port The next sections explain in more detail how you specify serial paths in each supported operating
34. u can now start working with the EEPROM chip SME containing EEPROM commands Command SMT 2 05 00 Enable the SPI master Here are some example SPI transfers RDSR read status register Response SMT2FF00 Status register is 00000000b Command SMT 2 06 WREN enable write operation Response SMT2FF Command SMT 2 05 00 RDSR read status register Response 5 2 02 Status register is 000000106 Command SMT 2 02 20 45 46 47 48 WRITE write 4 bytes at offset 20h Response SMT2FFFFFFFFFFFF Command SMT 2 03 20 FFFFFFFFFFFFFFFF READ read 8 bytes at offset 20h Response 24 SMT2FFFF45464748FFFFFFFF User Manual AxiCat 1 Wire Master The following example demonstrates the 1 Wire master function in combination with a DS18B20 temperature sensor AxiCat SPU GPIO11 DQ GPIO10 GND The temperature sensor comes in a TO 92 package that resembles a transistor The DS18B20 is wired for parasite power mode which means it taps power from the DQ line rather than the Vcc line We re going to demonstrate the strong pull up control mechanism as well Rather than implementing a real pull up circuit we ve hooked up a LED that lights up when SPU is active The circuit operates at 5 V It s assumed that program axicatserver is connected to the AxiCat in the example setup First we set up SPU GPIO11 and enable the 1 Wire master
35. ue is O7FFh This value is out of range and indicates that our particular DS18B20 couldn t convert the temperature properly The reason is the lack of an actual strong pull up circuit AxiCat SPU GPIO11 DS18B20 This is an example of a circuit with strong pull up The value of Rey be 1800 The 1 Wire master incorporates a powerful enumeration command Let s enumerate the DS18B20 sensor Search first slave OMN28 0000040CBBB2 C4 ROM code of the DS18B20 OMNN Search next slave OMN No next slave found ROM code of the DS18B20 sensor is 28 O000040CBBB2 C4 26 User Manual AxiCat Deploying as Development Board You can deploy your AxiCat as a general purpose development board for the family of ATmegal64A 324A 644A 1284 microcontrollers You can write your own software that runs on the AxiCat In doing so you effectively replace the main application with your own creation You don t need a third party programmer the preprogrammed bootloader and the aximcubldr software are all you need The avr gcc tool chain is good choice for developing software for the AxiCat With this tool chain which is available for Windows Linux and other operating systems you can write software in C C source code The output after building your source code is a HEX object file With the help of the bootloader you can run your newly created software in the AxiCat After you ve activated the boot