Home

User Manual - Weighing Scales

image

Contents

1. e Do not exceed the maximum capacity of the Scale e Clean and protect your scale after use 8 Page Adam Eguipment Company 2008 3 2 BATTERY OPERATION e The battery will operate continuously for 150 hours before requiring recharging The scale will alert you when the battery is within 10 hours of reguiring recharging by the indicator lamp above the low battery symbol to indicate that the battery is low voltage e When the battery requires charging the scale will turn off to prevent battery damage If the button is depressed at this point the indicator lamp will reappear and then the scale will again deactivate automatically e Charging time for a completely discharged battery is approximately 16 hours A full battery pack is recommended to keep the scale continuously operational Note More frequent charging of the battery prolongs its life 9 Page Adam Eguipment Company 2008 3 3 CHARGING BATTERY e Plug the power supply into the mains power then into the back of the IHS scale e The red indicator lamp will illuminate to indicate that the battery charger is functioning properly e The green indicator lamp will illuminate to indicate that the battery fully charged 3 4 BASIC OPERATIONS Power on and off Press ON OFF key to turn on the scale Then the display on the scale will show 88888 Press again to turn off the scale Zero the scale Depress the Zero to re zero the reading Change division you can use t
2. 000 0 is the number you have entered using the keys as above e Add the calibrated mass that is the same as the value displaved on the hook it the best that the mass is close to the capacity where possible e When the scale is stable press the ZERO The display shows HOLD e After a few seconds the calibration is complete When using slings chains or other material to support the calibration mass these items should be hung from the scale before setting the zero point so that when the calibration mass is added only the weight of the calibration mass is measured by the scale 12 Page Adam Eguipment Company 2008 5 0 PARAMETER 5 1 ENTER SETTING MODE Turn off the power of the scale and then turn the power on again Press the CHANGE key during self checking display shows Bee0 indicating the scale has entered the setting mode press the HOLD or CHANGE key to shift the parameter items Use ZERO key confirm and escape from setting the current item 5 2 PARAMETER SETTING TABLE FUNCTION DESCRIPTION DEFAULT Sets buzzer 0 0 Disable 1 Enable BEE Sets hold function 0 HoD 0 Disable 1 Enable Sets zero function 0 STDO zeroing allowed when unstable STD1 zeroing not allowed when unstable STD Sets auto backlight Only applies when the scale has 0 AUT an LCD display AUTO manual AUT auto Sets units 0 0 kg 1 lb CHT Sets save 0 0 not saved 1 sa
3. CAL SPECIFICATIONS Model No Capacity Division IHS 1 1000kg 0 2kg 0 5kg IHS 3 3000kg 0 5kg 1kg IHS 5 5000kg 1kg 2kg IHS 10 10000kg 2kg 5kg 2 3 SAFETY NOTICE The limit stated below is the Ultimate Overload Limits of the scales Adam Equipment Co Ltd Its directors owners and affiliated companies and organisations cannot be held liable for any resulting damage or injury sustained as a result of the machines being used in excess of their stated capacities or ultimate overload limits Model NO IHS 1 IHS 3 IHS 5 IHS 10 Max 1000kg 3000kg 5000kg 10 000kg capacity 1T 3T 5T 10T Overload 1500kg 4500kg 7500kg 15 000kg capacity 1 5T 4 5T 7 5T 15T NOTICE Do not use the scales if any parts are bent or loose or show signs of damage or wear Refer to the user manual 5 Page Adam Eguipment Company 2008 2 4 KEY DESCRIPTION Lea s Max 5000kg d 1kg 2kg gt a EMHZADAM ee Kg O O O O Power Charge t Hold Zero CE On Off Change Hold Zero 1 ON OFF Power switch use this key to turn on and turn off the scale CHANGE Division change key use this key to change division When in setting mode use this key to change parameter HOLD Hold function use this key to lo
4. ER ADAM Adam Equipment IHS SERIES P N 9520 Revision B2 October 2008 1 Page Adam Eguipment Company 2008 Easy Reference Model name of the scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and place 2 Page Adam Eguipment Company 2008 1 0 CONTENTS 1 0 CONTENTS terasse tentent asser eege ste A 3 2 0 INTRODUCTION tirisetes lon na iisa 4 2 1 Ra Rennel 4 2 2 TECHNICAL SPECIFICATIONS od d nd od on polda rov ka pool k a 5 2 5 SAFETY NOTICE EE 5 ZAKET DESCRIPTION od koto b 6 2 5 DISPLAY EE 7 3 0 OPERATION sn on 8 3 1 SAFETY INSTRUCTIONS ne ano io o po danse t titan a nt 8 32 BATTERY OPERATION spor rn 9 3 3 CHARGING BATTER eege 10 3 4 BASIC OPERATIONS gegen A r EE T E 10 4 0 CALIBRATION sind Ness tr s A na 12 S OPARAMETER usine etaient VEKA etat tiens 13 3 Page Adam Eguipment Company 2008 2 0 INTRODUCTION 2 1 INTRODUCTION IHS Series is a range of heavy duty crane scales used to weigh very large 4 Page masses The main features include Easy Operation amp Rugged construction 22mm super big amp bright red LED display with view angle 360 degree rotary safety hook design easy to use Overload safety up to 200 One charge can last 150 hours Aluminum die casting housing Large remote control handset Adam Equipment Company 2008 2 2 TECHNI
5. ck the display There is a LED indication light on the bottom of the display Press the HOLD key again to cancel HOLD function ZERO Re zero key use this key to return to zero reading 6 Page Adam Eguipment Company 2008 2 5 DISPLAY POWER Power on mode CHARGE Charging mode 4 Low battery HOLD Hold mode ZERO Zero indicator 7 Page Adam Eguipment Company 2008 3 0 OPERATION 3 1 SAFETY INSTRUCTIONS Read this manual carefully before you operate the IHS Crane Scale e Unpack the Crane Scale carefully from the packing e Attach it to your hoist or equivalent existing equipment securely at the ground level in the upright position Make sure that the eguipment to which the scale is attached is in proper condition The operator should be trained for its safe operation e Carry out regular visual inspection for any damage or wear and teat on parts Particularly the split pins at the book and eyebolts and the inner wall of the hook and all joints should be checked regularly If any damage or wear has taken place replace the parts e Do all inspection and maintenance work when the scale is not in use e Do not expose the scale to extreme temperatures The operating temperature range is 0 C to 40 C e Secure the sample to be weighed in the hook of the scale Ensure that the sprung Safety Lever returns to its resting position which prevents the sample from slipping out of the hook
6. he CHANGE key to change division HOLD when required such as when the reading is not stable or you cannot pause to record a reading vou can use the HOLD key to lock the reading so that you can read it easily later after vou finish reading press HOLD again to return to normal weighing mode Note The HOLD key has no affect if the Hold parameter has been disabled See section 5 1 10 Page Adam Eguipment Company 2008 Overload Warning please do not add any item that exceeds the maximum capacity of the scale When the buzzer is sounded and the display shows remove the item to avoid damage to the load cell and scale 3 5 REMOTE CONTROLLER 11 Page A Determine increments in which the weight display B Hold the settled values C Zero the scale D Backlight only used on scales with LCD display Adam Eguipment Company 2008 4 0 CALIBRATION e Pressing ZERO when scale is power on e The display on the scale will show SPAN Make sure the hook is empty e Depress the ZERO button The display on the scale will show 00000 after stable After few seconds zero calibration is now complete e After zero calibration display shows a value of mass for span calibration you can change the weight by using the CHANGE key to move the active digit flashing and the HOLD key to increment a digit e Press the CHANGE to confirm For example the display on the IHS will display 8000 0 3
7. products visit our website at www adameguipment com 16 Page Adam Eguipment Company 2008
8. ve YES 13 Page Adam Equipment Company 2008 14 Page Adam Equipment Company 2008 CE Manufacturer s Declaration of Conformity This product has been manufactured in accordance with the harmonised European standards following the provisions of the below stated directives Electro Magnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC Adam Eguipment Co Ltd Bond Avenue Denbigh East Milton Keynes MK1 1SW United Kingdom FCC COMPLIANCE This eguipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the eguipment is operated in a commercial environment The eguipment generates uses and can radiate radio freguency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be reguired to correct the interference at his own expense Shielded interconnect cables must be employed with this eguipment to insure compliance with the pertinent RF emission limits governing this device Changes or modifications not expressly approved by Adam Eguipment could void the user s authority to operate the eguipment WEEE COMPLIANCE SE a
9. y Sealed Lead Acid m Battery i 3 ue Must be recycled Properly Any Electrical or Electronic Equipment EEE component or assembly of parts intended to be incorporated into EEE devices as defined by European Directive 2002 95 EEC must be recycled or disposed using techniques that do not introduce hazardous substances harmful to our health or the environment as listed in Directive 2002 95 EC or amending legislation Battery disposal in Landfill Sites is more regulated since July 2002 by regulation 9 of the Landfill England and Wales Regulations 2002 and Hazardous Waste Regulations 2005 Battery recycling has become topical and the Waste Electrical and Electronic Equipment WEEE Regulations are set to impose targets for recycling 15 Page Adam Equipment Company 2008 ADAM EQUIPMENT is an ISO 9001 2000 certified global company with more than 35 years experience in the production and sale of electronic weighing eguipment Adam products are predominantly designed for the Laboratory Educational Medical retail and Industrial Segments The product range can be described as follows Analytical and Precision Balances Compact and Portable Balances High Capacity Balances Moisture analysers balances Mechanical Scales Counting Scales Digital Weighing Check weighing Scales High performance Platform Scales Crane scales Medical Scales Retail Scales for Price computing For a complete listing of all Adam