Home
Manual - ETS
Contents
1. 1 Press the Off button located on the EMCenter screen EMPower 7002 001 os Ed EMSwitch 7001 001 NC NC EMSwitch 7001 021 Switch off system EMSense 7007 001 EMControl 7006 00 EMSense 7007 002 Standby Press to start 30 000 000 MHz 2 Press OK to switch off the system The standby light located on the front panel of the EMCenter will flash and then will illuminate steadily Note When the EMCenter is in standby mode touch the screen anywhere to reboot 3 Turn the power switch located on the back panel of the EMCenter to the off position Remove the power cord from the power connector on the back panel of the EMCenter 5 Remove the interlock jack from the interlock connector on the back panel of the EMCenter ets lindgren com Operation 21 Using the EMField Generator Once the EMCenter is switched on the Model 7008 Series EMField Generator can be activated from the main screen CO By pressing the status button proceeded by the Ack button the start up procedure of the EMField will begin Once this procedure has been completed successfully the amplifiers in the EMField will be powered The system is now heating up to its final temperature of 75 It will be ready to be switched to operate once it has reached a temperature above 50 22 Operation ets lindgren com Forward power Reflected power A Home 4 4 dBm 7 4 dBm Model ETS L
2. e Coaxial N Type Cable A coaxial cable is used to connect the plug in card with the EMField The coaxial cable needs to be fitted with an N type connector on both sides The maximum allowed attenuation of the cable for proper system operation is 10 dB at 6 GHz The selected cable also needs to be able to handle a DC current of 8 amps Service Procedures CoNTACTING ETS LINDGREN Note Please see www ets lindgren com for a list of ETS Lindgren offices including phone and email contact information SENDING A COMPONENT FOR SERVICE 1 Contact ETS Lindgren Customer Service to obtain a Service Request Order SRO 2 Briefly describe the problem in writing Give details regarding the observed symptom s or error codes and whether the problem is constant or intermittent in nature Please include the date s the service representative you spoke with and the nature of the conversation Include the serial number of the item being returned 3 Package the system or component carefully If possible use the original packing materials or carrying case to return a system or system component to ETS Lindgren 10 Introduction ets lindgren com CALIBRATION SERVICES e Annual Calibration For reliable and repeatable long term performance annual recalibration of your measuring device by an ETS Lindgren experienced technician is recommended The ETS Lindgren calibration team will calibrate most any type or brand of measuring device Additional i
3. System Benefits i AI do c uada t 8 System Safely hem harena ae Ert e e M Ene t e e Eu gd 8 Standard Configurations Caveat erit a e D dece ail e exe deve 9 EMCenter Modular RF Platform Required seen 9 Optional Items 1e I Leg Pe teret f E pede ft beret e 10 Service Procedures 1 aci egi Par teta ees iode ar eraty te Ee ge het 10 Gontacting odere eds 10 Sending a Component for Service 10 Calibration Services enne 11 2 0 nuu LY NENN NN ARWR AUAN DNA NY ARENNAU LLM A dAn 13 Power Specifications iun oce ER ede ERR ENA YDY Fn e FEE Y RO 13 Performance 13 Safety Specifications 14 Physical Specifications e eode eed eroi e hut 14 Environmental Specifications sssssssssssssss seen nnne nennen 14 3 0 Is LL Le CEFNDY occid bibo da bn DN Y EC RERO FER ENDO RN RR FF das 15 Plug In Card Installation 2 cerei iiir edicit taedet dec a 15 Hardware 16 Field Polarization and Reference 17 4 0
4. LTE Band 1 3 4 25 UMTS 60601 1 2 medical 2400 2570 MHz Bluetooth WLAN 28 802 11 b g n 2450 MHz 2m Vim Pulse 217 Hz RFID 2450 LTE band 7 5240 MHz 5100 5800 MHz 5500 MHz 3m 9 V m Pulse 217 Hz 5785 MHz GSM 1 W 1800 MHz WIMAX 3G 1W 2600 MHz WiMAX 1 26W 3500 MHz Wi Fi 1W 5000 MHz g00 2000 MHz 1300 MHz Pulse 577 us 4600 us 13309 machines with 8004 2000 MHz lm 24 V m Pulse 577 us 600 us internal power supply ETSI 301 489 1 T FE 400 2700 MHz 3m owm AM 80 1 kHz or A00 Hz 3 The distance between the transmitting antenna and the ME equipment or ME system may be reduced to 1 m For compliance to EN61000 4 3 and required field amplitude it is necessary to test at a distance of 2 m EMField support measurements starting at 1000 MHz ets lindgren com Standards 35 This page intentionally left blank 36 Standards ets lindgren com Appendix B Warranty Scope and Duration of Warranties Seller warrants to Buyer that the Products to be delivered hereunder will be 1 free from defects in material manufacturing workmanship and title and 2 conform to the Seller s applicable product descriptions and specifications if any contained in or attached to Seller s quotation If no product descriptions or specifications are contained in or attached to the quotation Seller s applicable product descriptions and specifications in
5. e EMCenter Integration Allows for easy touchscreen operation and several control interfaces such as GPIB Ethernet and USB For more information about the EMCenter see page 9 System Safety The EMField will only be able to power on if all connections are properly made In addition the EMField will shut down immediately if the interlock of the EMCenter is triggered The start up procedure consists of three phases that ensure the safe use of the EMField If the EMField is not connected correctly or if there is any other irregularities the safety measures of this startup procedure will be triggered In each phase the supply power is increased building up to the DC power needed for normal usage 1 Probing Stage When the startup command is given to the EMField a safe probe signal is sent through the coaxial cable to the EMField If the EMField does not respond correctly to the probe signal the startup procedure is aborted This probe signal is harmless to other eguipment and will therefore not cause defects to other instruments in case of an incorrect connection 2 Communication Stage After a successful probing phase the plug in card will attempt to communicate with the intelligent backplane of the EMField If the intelligent backplane does not respond the startup procedure is aborted 8 Introduction ets lindgren com 3 Final Startup When communication is established the final DC power will be applied on the coaxial c
6. mec 19 Operations Warnings amp Precautions ssssssssssssssseeseeeeeen eene 19 Powering On and Off EMCenter sssssssssssssesesee LLY LL LL HEL ener nnne nennen 20 Power Oni n 20 Power Off en SD E GT YG ED cbe dedu vast Ee 21 Using the EMField Generator cccccccecececeeeeeceeeeeeeee scence eeaeeecaaeeseaeeseeeeeseaeeesaeeseeeseeeeess 22 Remote Control of the EMField sss nnns 23 5 0 EMField Command Set eere WYW WYW WN ri rum ecrire 25 Gomimands s top Xa cce 25 General GommandSu ieu nad dera rdi nee e daas 25 ets lindgren com iii Power Meter Commands 0ccccccccccceeeeeececeeeseceaueeseceseeseuaueeeeseeeeseuseauaaseeeeeeeeeaneneees 28 Error C OdOS xot n b c uL i et tuit tato ELE 29 Generic Error Codes eiae a eee Hed terae c E eerie ded 29 Module Specific Error Codes Amplifier 29 Module Specific Error Codes Backplane sse 31 Module Specific Error Codes Plug In Card ssssssseeeeees 31 Appendix A Standards eni ni dece aio aid o aacra QU E RU Eno 33 Appendix B Warranty 5 rore er ne iore nice ni du mic inc de 37 Scope and Duration of Warranties 37 Wariranty EXCIUSIOTnS 2 6i adio euo dia dim 38 Buyer s Remedies tet re ro
7. Buyer s direction 4 any design specification or instruction furnished by Buyer its employees agents or contractors 5 any alteration of the product by persons other than Seller 6 combining Seller s product with any product furnished by others 7 combining incompatible products of Seller 8 interference with the radio frequency fields due to conditions or causes outside the product as furnished by Seller 9 improper or extraordinary use of the product or failure to comply with any applicable instructions or recommendations of Seller including maintenance calibration and cleaning procedures and intervals or 10 acts of God acts of civil or military authority fires floods strikes or other labor disturbances war riot or any other causes beyond the reasonable control of Seller This warranty does not include 1 batteries 2 cables 3 gasket 4 fingerstock or any item that is designed to be consumable Seller does not warranty products of others which are not included in Seller s published price lists Buyer s Remedies 38 If Seller determines that any product fails to meet any warranty during the applicable warranty period Seller shall correct any such failure by either at its option repairing adjusting or replacing without charge to Buyer any defective or nonconforming product or part or parts of the product Seller shall have the option to furnish either new or exchange replacement parts or assemblies W
8. No error e 1 3 3V error e 2 5V error e 4 10V error e 8 10V error e 16 50V error e 32 current driver error 64 current final error e 128 temperature error e 256 power error e 512 driver fet adjustment error e 1024 final fet adjustment error e 2048 Oven too cold e 4096 Oven too hot 8192 memory error e 16384 driver vGate min limit e 32768 driver vGate max limit e 65536 driver adjustment timed out e 131072 final vGate min limit e 262144 final vGate max limit e 524288 final adjustment timed out Some numbers represent multiple of the previously mentioned errors occurring at ones For example reply e 3 error 1 and 2 3 3V and 5V error e 5 zerror 1 and 4 3 3V and 10V error e 6 error 2 and 4 5V and 10V error e Etc ets lindgren com EMField Command Set 27 PowER METER COMMANDS Command Description Response POW value Get measure power level in dBm value FWD or RFL Reply for example 12 34 FREOUENCY MIN Get the minimal freguency in Hz Reply for example 1000000000 FREOUENCY MAX Get the maximum freguency in Hz Reply for example 6000000000 Setthef FREQUENCY lt space gt itd MU wane lt value gt frequency in Hz for example 500000000 STER Reply OK
9. effect on the date of shipment shall apply The criteria for all testing shall be Seller s applicable product specifications utilizing factory specified calibration and test procedures and instruments All product warranties except the warranty of title and all remedies for warranty failures are limited to three years Product Warranted Duration of Warranty Period Model 7008 Series EMField Generator Three Year s Model 7008 Series EMField Plug in Card Three Year s Any product or part furnished to Buyer during the warranty period to correct a warranty failure shall be warranted to the extent of the unexpired term of the warranty applicable to the repaired or replaced product The warranty period shall commence on the date the product is delivered to Buyer however if Seller assembles the product or provides technical direction of such assembly the warranty period for such product shall commence on the date the assembly of the product is complete Notwithstanding the foregoing in the event that the assembly is delayed for a total of thirty 30 days or more from the date of delivery for any reason or reasons for which Seller is not responsible the warranty period for such product may at Seller s options commence on the thirtieth 30th day from the date such product is delivered to Buyer Buyer shall promptly inspect all products upon delivery No claims for shortages will be allowed unless shortages are reported t
10. EL ne y i Bee oe P PL I t d 38 Appendix C EC Declaration of 41 iv ets lindgren com This page intentionally left blank ets lindgren com Notes Cautions and Warnings oeo Note Denotes helpful information intended to provide tips for better use of the product CAUTION Denotes a hazard Failure to follow instructions could result in minor personal injury and or property damage Included text gives proper procedures WARNING Denotes a hazard Failure to follow instructions could result in SEVERE personal injury and or property damage Included text gives proper procedures Safety Information Owe gt a O i Refer to Manual When product is marked with this symbol see the instruction manual for additional information If the instruction manual has been misplaced download it from www ets lindgren com or contact ETS Lindgren Customer Service High Voltage Indicates presence of hazardous voltage Unsafe practice could result in severe personal injury or death Protective Earth Ground Safety Ground Indicates protective earth terminal You should provide uninterruptible safety earth ground from the main power source to the product input wiring terminals power cord or supplied power cord set Waste Electrical and Electronic Equipment WEEE Directive European Union At end of useful life this product should be deposit
11. Model 7008 Series EMField Generator User Manual SWETS LINDGREN An ESCO Technologies Company ETS Lindgren Inc reserves the right to make changes to any products herein to improve functioning or design Although the information in this document has been carefully reviewed and is believed to be reliable ETS Lindgren does not assume any liability arising out of the application or use of any product or circuit described herein nor does it convey any license under its patent rights nor the rights of others All trademarks are the property of their respective owners Copyright 2015 by ETS Lindgren Inc All Rights Reserved No part of this document may be copied by any means without written permission from ETS Lindgren Inc Trademarks used in this document The ETS Lindgren logo is a registered trademark of ETS Lindgren Inc and EMField TILE EMCenter EMQuest Calibration Services Plus and EMPower are trademarks of ETS Lindgren Inc Revision Record MANUAL EMFIELD GENERATOR Part 399396 Rev A Revision Description Date A Initial Release September 2015 ii ets lindgren com Table of Contents Notes Cautions and vi Safety InTOFmatlODi aiio c nd a DO I D Rd Rub sa PUE XE VIEN ROVS ADLER RUD SEES Cun ad vi 1 0 IntroductiOn s sisien YY nex ei Y YW rii uu c vina 7 EMField Pl g in Gard 3 1 bp e Dtm Rena DD DG 7
12. able to power the EMField The amplifiers in the EMField can now be switched on and are ready to operate Standard Configuration e EMField Generator e EMField Plug in Card EMCenter Modular RF Platform Required The EMCenter Modular RF Platform is required for operation and is sold separately SNETS LINDGREN EMCenter Front Panel Back Panel The EMCenter may be controlled from a computer using these software products e ETS Lindgren TILE Totally Integrated Laboratory Environment e ETS Lindgren EMQuest Data Acquisition and Analysis Software e Other test automation software Contact ETS Lindgren for ordering information ets lindgren com Introduction Optional Items e Transport Case Designed for on site and facility transports The EMField must be stored in the transport case when it is shipped between locations If the transport case is not used the customer must provide an alternative and equal or better method of protection for the EMField transportation It does not provide sufficient protection for air travel or other long distance shipping Additional or different protective packaging is needed in those situations The EMField might be damaged if the transport case is handled in a rough manner Q WARNING The transport case is designed for short distance e Antenna Stinger Mount Boom A custom made antenna boom can be mounted on the back It is 50 cm long and has a diameter of 40 mm
13. arranty service shall be performed at the Seller s factory or the Buyer s site at the sole discretion of the Seller Within the warranty period the Buyer shall be responsible for all transportation to the Seller s factory and the Seller shall be responsible for transportation of goods to the Buyer s site Warranty ets lindgren com Within the contiguous 48 United States warranty service performed during the applicable warranty period will be performed without charge to Buyer during Seller s normal business hours After the warranty period service will be performed at Seller s prevailing service rates Subject to the availability of personnel after hours service is available upon request at an additional charge Outside the contiguous 48 United States travel and per diem expenses when required shall be the responsibility of the Buyer or End User whichever is applicable regardless of the warranty period The remedies set forth herein are conditioned upon Buyer promptly notifying Seller within the applicable warranty period of any defect or non conformance and making the product available for correction The preceding paragraphs set forth Buyer s exclusive remedies and Seller s sole liability for claims based on failure of the products to meet any warranty whether the claim is in contract warranty tort including negligence and strict liability or otherwise and however instituted and upon the expiration of the applicable warranty pe
14. d the mains inlet of the plug in card Switch the main power switches on both mains inlets to the ON position Touch the touchscreen on the front panel of the EMCenter to activate the EMField The system is now ready to be used Installation ets lindgren com Field Polarization and Reference Point In order to perform radiated immunity measurements standards require a certain distance from the field generating antenna to the Equipment Under Test EUT In most immunity setups the tip of the transmitting antenna is used to determine the distance to the EUT Since the actual antenna of the EMField is not visible a small hole in the nose of the is used as a reference point to determine this distance For most test setups it is also necessary to know the polarization of the field generated by the antenna FIELD POLARIZATION ets lindgren com Installation 17 This page intentionally left blank 18 Installation ets lindgren com 4 0 Operation CAUTION Before placing into operation follow the information provided in Safety Information on page vi Operations Warnings amp Precautions CAUTION Never use the EMField without a protective earth connection CAUTION Please make sure that the airflow through the in and outlets of the EMField are not restricted to maintain a constant temperature The cooling system is designed to operate in the specified operating temperature range the equipment CAUTION To maxi
15. ed at an appropriate waste disposal facility for recycling and disposal Do not dispose of with household waste Note For warnings and precautions while operating the EMField see page 19 ets lindgren com 1 0 Introduction The ETS Lindgren Model 7008 Series EMField Generator is a unique integrated solution for Radiated Immunity testing including IEC EN 61000 4 3 It combines an amplifier directional couplers and an antenna array into one remarkable simplified design Almost all of the generated power is converted into useable field strength The supporting instrumentation signal generator laser probe controller and EMField power supply are plug and play card modules that insert into the back of the EMCenter Modular RF Platform which is typically placed in the control room The EMField is available in a variety of models e Model 7008 001 6 GHz 10 V M e Model 7008 002 6 GHz 3 V M e Model 7008 003 3 GHz 10 V M e Model 7008 004 3 GHz 3 V M The EMField is air cooled Air is drawn in at the back and blown out along the external cooling ribs through the side air outlets and then out of the openings in the foam cones The cooling system keeps the internal amplifiers at a constant operating temperature Failure to meet the specified environmental temperature range might result in a too high or too low amplifier temperature The power RF input and communication connection run through one coaxial cable T
16. eld Command Set 29 Error Code Description 512 Not for customer Null pointer 513 First send the startup command 514 Already started 515 Regulating FET 516 3V3 out of range 517 5V out of range 518 10V out of range 519 10V out of range 520 50V out of range 521 Driver current out of range 522 Final current out of range 523 Temperature out of range 524 Power out of range 525 Driver fet adjustment error 526 Final fet adjustment error 527 Going to standby 528 Going to operate 529 Going to off 530 Oven too cold 531 Oven too hot 532 Calibrating busy 533 Power not updated 30 EMField Command Set ets lindgren com MODULE SPECIFIC ERROR CODES BACKPLANE Error Code Description 551 Communication busy 552 Amplifier error 553 Amplifier wrong IDN 554 Amplifier wrong answer 555 Amplifier time out 556 Amplifier wrong mode 557 No amplifier connected 558 Received command length are no digits 559 Received command length incorrect MODULE SPECIFIC ERROR CODES PLUG IN CARD Error Code Description 504 Hardware failure 575 Communication busy 576 Communication time out 577 Power supply already on 578 Power supply off 579 Incorrect impedance 580 Impedance short 581 Impedance open 582 External unit is not connected 583 Unknown error 584 SW update 50V back
17. his cable is connected at the back to an N type connector The EMField has a standard 1 4 20 UNC 1B thread on the bottom This can be used to mount on a tripod antenna tower or boom mount EMField Plug in Card The EMField includes a two slot plug in card Model 7008 100 for the EMCenter It combines power RF input and communication within the coaxial cable to the EMField The plug in card has a separate mains input connection to power the EMField An SMA connector is used for the RF input and an N type connector for the connection to the EMField ets lindgren com Introduction 7 System Benefits e Eliminate Power Loss HF power loss is at a minimum reducing energy consumption and eliminating the need for expensive high power amplifiers e Integrated Power Meters Eliminates the need for separate external coupler and power meters e Easy to Use By using only one coaxial cable for the transport of the RF signal the communication signals and DC power supply are easy to set up this saves time and costs as well as reduces the risk of eguipment damage due to incorrect eguipment connections e Fully Compliant Fully compliant with the international EMC immunity standards These standards describe aspects such as the freguency field strength and homogeneity e High Value for Money With the integrated coupler and power meters is a complete EMC immunity testing setup in addition calibrations costs are reduced
18. indgren EMField 7008 001 1 0 AAA voltage 49 880V AAA temperature 5 72 20 AAA current 25 64 Status Power meter Frequency 3 000 000 000 GHz In the EMField control screen the parameters of the system can be read In order to generate an EM field the system must be switched to operate It is important to enter the frequency of the generator driving the EMField to read the correct power meter level Entering the actual frequency will automatically correct for the frequency dependent coupler and power meter response inside the amplifiers Normal operating parameters are e Amplifier temperature 75 C 59C e EMField DC voltage 50Vdc lt lt EMField current 5 to 8 A max Remote Control of the EMField The EMField can be controlled remotely through the interfaces of the EMCenter The exact communication protocol can be found in the EMCenter Modular Test System User Manual The specific commands for the EMField begin on page 25 ets lindgren com Operation 23 This page intentionally left blank 24 Operation ets lindgren com 5 0 EMField Command Set Commands GENERAL COMMANDS Command Description Response ID NUMBER Returns unique identifier number Reply for example 1 58 95 146 21 0 0 124 LOCAL Return to local mode the local display is used to set items Reply OK VERSION HW Returns the hardware version Reply for example 2 IDN Return
19. mize safety the EMField will only power on when all connections are properly made In addition the EMField will shut down if the interlock of the EMCenter is triggered CAUTION Please use a suitable coaxial cable to connect the PSU plug in card with the EMField fitted with an N type connector on both sides maximum allowed attenuation of 10dB at 6GHz and able to handle a DC current of 8 amps ww CAUTION Verify that your mains voltage is within the operating range of ets lindgren com Operation 19 Powering and Off EMCenter Note For information on using the EMCenter touchscreen see the EMCenter Modular Test System User Manual POWER ON Note Verify all cards are installed correctly in the EMCenter 1 Plug the power cord from the mains inlet on the back panel of the EMCenter Modular RF Platform into a power outlet 2 Plug the interlock jack into the interlock connector on the back panel of the EMCenter 3 Turn the power switch located on the back panel of the EMCenter to the on position 4 Touch anywhere on the EMCenter screen It will take approximately 20 seconds to boot The Information screen will flash and then the Home screen will display EMSwitch 7001 001 NC NC DL Y EMSense 7007 001 No probe EMControl 7006 001 358 9 100 0 cm EMSense 7007 002 Standby Press to start 30 000 000 MHz Sample EMCenter Home Screen 20 Operation ets lindgren com
20. n Cable Dis connect Intrinsically safe Voltage 50 VDC Safe Voltage Interlock Hardware interlock Physical Specifications Connections Tripod mount 1 4 20 UNC Thread Length 860 mm 33 8 in Width 250 mm 9 8 in Height 250 mm 9 8 in e 7008 001 11 kg 24 2 Ib e 7008 002 10 kg 22 0 Ib e 7008 003 10 kg 22 0 Ib e 7008 004 9 kg 19 8 Ib Weight Environmental Specifications Temperature Range 10 C 40 C 50 F 104 F Relative Humidity 1096 9095 non condensing 14 Specifications ets lindgren com 3 0 Installation Plug In CAUTION Before connecting any components follow the information provided in Safety Information on page vi Card Installation Oe CAUTION The EMField plug in card reguires a protective earth connection The mains power source for the eguipment must supply an uninterrupted safety ground to the IEC input connector Note Due to the width of the EMField plug in card two consecutive empty slots are reguired for installation Determine in which empty slot s in the EMCenter Modular RF Platform you want to install the EMField Plug in Card Looking at the back of the EMCenter the slots are numbered 1 through 7 from left to right Remove the blank panel from the slot by removing the two screws at the top of the blank panel and the two screws at the bottom Carefully insert the EMField card in
21. nformation is available at www ets lindgren com e Calibration Services Plus Calibration Services Plus is a customized optional program to help you expertly maintain your test and measurement assets It is designed to address the challenges of managing the calibration and repair of test and measurement components including scheduling and planning to ensure peak performance Additional information is available at www ets lindgren com ets lindgren com Introduction 11 This page intentionally left blank 12 Introduction ets lindgren com 2 0 Specifications Power Specifications Supply Voltage 115 VAC 230 VAC Max Power Consumption 7008 001 400 W 7008 002 300 W 7008 003 300 W 7008 004 200 W Performance Specifications 7008 001 7008 002 7008 003 7008 004 Freguency Range 1GHz 6 GHz 1GHz 6 GHz 1GHz 3 GHz 1 GHz 3 GHz TME Field 10 V m 3V m 10 V m 3V m Input Connector N Type Max Input Power to Reach TME Field 0 dBm Number of Internal Power Meters 2 Forward amp Reflected Power Meter Type Integrated EMPower Directional Coupler Integrated Three Meter Equivalent TME Field 1 5m x 1 5m homogeneous field 3m according to IEC 61000 4 3 ets lindgren com Specifications 13 Safety Specifications Safety Circuit Safe start amp shutdow
22. o Seller in writing within ten 10 days after delivery No other claims against Seller will be allowed unless asserted in writing within thirty 30 days after delivery or assembly if the products are to be assembled by Seller or in the case of alleged breach of warranty within the applicable warranty period ets lindgren com Warranty 37 Warranty Exclusions Except as set forth in any applicable patent indemnity the foregoing warranties are exclusive and in lieu of all other warranties whether written oral express implied or statutory EXCEPT AS EXPRESSLY STATED ABOVE SELLER MAKES NO WARRANTY EXPRESS OR IMPLIED BY STATUTE OR OTHERWISE WHETHER OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE OR USE OR OTHERWISE ON THE PRODUCTS OR ON ANY PARTS OR LABOR FURNISHED DURING THE SALE DELIVERY OR SERVICING OF THE PRODUCTS THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF Warranty coverage does not include any defect or performance deficiency including failure to conform to product descriptions or specifications which results in whole or in part from 1 negligent storage or handling of the product by Buyer its employees agents or contractors 2 failure of Buyer to prepare the site or provide an operating environmental condition in compliance with any applicable instructions or recommendations of Seller 3 absence of any product component or accessory recommended by Seller but omitted at
23. or ERROR FREQUENCY Get the frequency in Hz Reply for example 500000000 FILTER MIN Get the minimal meter filter Reply for example O FILTER MAX Get the maximum meter filter Reply for example 7 Set filter to automatic FILTER AUTO Reply OK FILTER lt space gt lt value gt Set the filter lt value gt 1 2 3 4 5 6 or 7 Reply OK or ERROR FILTER Get the current filter Reply for example 1 28 EMField Command Set ets lindgren com Error Codes The following tables show the generic error codes and the product specific error codes for the Model 7008 Series EMField Generator This includes the error codes for the amplifier backplane and plug in card that are part of the EMField system GENERIC ERROR CODES Error Code Description 1 Wrong command 2 Parameter too high 3 Parameter too low 4 Invalid parameter 5 Buffer overflow 6 Already in progress 7 Parity error MODULE SPECIFIC ERROR CODES AMPLIFIER Error Code Description 500 Already in standby 501 Already in operate 502 Already in off 503 Not in standby 504 Hardware failure 506 Out of specification 507 Power measurement frequency not set 508 Power measurement over range 509 Power measurement under range 510 Power measurement no calibration data 511 No error logs available ets lindgren com EMFi
24. plane not off 585 SW update 50V backplane not on ets lindgren com EMField Command Set 31 Error Code Description 586 SW update software download not started 587 SW update sync retries failed 588 SW update reboot unit failed 589 SW update amplifier to off mode error 590 SW update transparent mode on error 591 SW update transparent mode off error 592 SW update binary frame error 593 SW update binary frame header error 594 SW update binary frame header size error 595 Illegal backplane command length 596 Length error received command length are no digits 597 Length error received command length incorrect 598 Mains on sequence error BPL 50V switch error 599 Mains on sequence error AMP startup error 32 EMField Command Set ets lindgren com Appendix A Standards The Model 7008 001 EMField Generator is a 10 V m TME system In other words a field generator capable of generating 10 V m at 3 meter with headroom for 80 AM The peak field strength at 3 meter is therefore 18 V m resulting in 54 V m at 1 meter distance The tables on the following pages provide an overview of the standards for which the 10V m TME system can be used laboratory AM 80 1 kHz 3m 10 V m AM 80 1 kHz 3m 3m 3m DNV SFC 24 1000 2000 MHz maritime Germanische Lloyd part 1 1000 2000 MHz maritime Lloyd s Registe
25. r TSNI maritime 1000 2000 MHz Veritas Section 6 maritime 1000 2000 MHz IEC 60945 m lt AM 80 1 kHz 400 Hz AM 80 1 kHz or 400 Hz IEC 60533 maritime electric 1000 2000 MHz installations on ships ets lindgren com Standards 33 80 1 kHz RUN 80 1 kHz Pulse 1 Hz aos ovm 200 Hz Pulse 50 1428 1516 MHz 1710 1785 MHz EN 12016 lifts escalators 1840 2170 MHz 2300 2655 MHz EN 50130 4 alarm systems 1000 2700 MHz EN 50293 road traffic 1889 1891 MHz signal systems EN 61000 6 1 1400 2000 MHz generic AM 80 1 kHz domestic 2000 2700 MHz AM 80 1 kHz AM 80 1 kHz EN 61000 6 2 1400 2000 MHz generic industrial 2000 2700 MHz EN 61000 6 7 1400 2000 MHz EVS EN safety related systems 2000 2700 MHz EN 60335 1 ENG9951 1400 2000 M pte AM 80 1 kHz EN 50121 3 2 1400 weo 2100 Mie MHz railway rolling owaj 80 1 kHz SS 2100 2500 MHz ah 21 4 1400 2100MHz 2100 MHz V m railway signalling amp 80 1 kHz telecom 2100 2500 MHz 5 V m 34 Standards ets lindgren com a a EN 50121 5 1400 2100 MHz railway fixed AM 80 1 kHz power supply installations 2100 2500 00 2500 MHz 5 swm swm 1700 1990 MHz GSM 1800 CDMA 1900 1720 MHz 28 GSM 1900 1845 MHz 2m V m Pulse 217 Hz DECT 1970 MHz i
26. riod all such liability shall terminate IN NO EVENT SHALL SELLER BE LIABLE TO BUYER FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND ARISING OUT OF OR AS A RESULT OF THE SALE DELIVERY NON DELIVERY SERVICING ASSEMBLING USE OR LOSS OF USE OF THE PRODUCTS OR ANY PART THEREOF OR FOR ANY CHARGES OR EXPENSES OF ANY NATURE INCURRED WITHOUT SELLER S WRITTEN CONSENT DESPITE ANY NEGLIGENCE ON BEHALF OF THE SELLER IN NO EVENT SHALL SELLER S LIABILITIES UNDER ANY CLAIM MADE BY BUYER EXCEED THE PURCHASE PRICE OF THE PRODUCT IN RESPECT OF WHICH DAMAGES ARE CLAIMED This agreement shall be construed in accordance with laws of the State of Texas In the event that any provision hereof shall violate any applicable statute ordinance or rule of law such provision shall be ineffective to the extent of such violation without invalidating any other provision hereof Any controversy or claim arising out of or relating to the sale delivery non delivery Servicing assembling use or loss of use of the products or any part thereof or for any charges or expenses in connection therewith shall be settled in Austin Texas by arbitration in accordance with the Rules of the American Arbitration Association and judgment upon the award rendered by the Arbitrator may be entered in either the Federal District Court for the Western District of Texas or the State District Court in Austin Texas all of the parties hereto consenting to personal juri
27. s the ID of the system Reply for example ETS Lindgren EMField 7008 100 X X X RESET Reset the module This will e Clear all errors e Clear all occurred crowbars e Reset the filter to filter 1 e Reset the frequency to 3 GHz e Setthe amplifier to standby mode if this fails an error is replied Reply OK or error code CLEAR All errors are cleared and crowbars are reset Reply OK MAINS Get the state of the mains Reply 1 ON Reply 0 OFF MAINS lt space gt lt value gt Turn the main power ON or OFF lt value gt ON or OFF Reply OK or error code STANDBY Set the EMField in the standby mode FETs are biased Reply OK or error code ets lindgren com EMField Command Set 25 Description Response Set the EMField in the operate mode RF path opened OPERATE Reply OK or error code Returns in which mode the EMField is MODE Reply for example Operate Returns the current measured by the plug in card in CURRENT ampere Reply for example 1 2 Returns the temperature in degrees Celsius TEMP Reply for example 23 6 26 EMField Command Set ets lindgren com Description Response STATUS Returns a number which indicates what kind of error is occurred This includes the following replies e O
28. sdiction of the venue of such court and hereby waive the right to demand a jury trial under any of these actions ets lindgren com Warranty 39 This page intentionally left blank 40 Warranty ets lindgren com Appendix EC Declaration of Conformity ETS Lindgren Inc declares these products to be in conformity with the following standards following the provisions of EMC Directive 2004 108 EC and Low Voltage Directive 2006 95 EC Model 7008 Series EMField Generator Emission EN 61326 1 2006 Class A Electrical equipment for measurement control and laboratory use Immunity EN 61326 1 2006 Industrial level performance criteria A Electrical equipment for measurement control and laboratory use Safety EN 61010 1 2010 Safety requirements for electrical equipment for measurement control and laboratory use Technical Construction Files are available upon request ets lindgren com EC Declaration of Conformity 41
29. to the slot s of the EMCenter Tighten the four Screws Turn on the EMCenter The EMCenter will automatically detect the newly installed EMField card Depending on the test setup requirements connect coaxial cables to the relay connections on the back panel of the EMCenter Connect the EMCenter to a personal computer using USB RS 232 Ethernet or IEEE optional Plug the interlock into the connector on the back of the EMCenter The card installation is complete You can control EMField through the EMCenter touchscreen with ETS Lindgren TILE Totally Integrated Laboratory Environment ETS Lindgren EMQuest Data Acquisition and Analysis Software and other test automation software packages Contact ETS Lindgren for additional information ets lindgren com Installation 15 Hardware Configuration 16 The hardware configuration is carried out in the following steps Make sure that all connections to the plug in card are made Connect a suitable N type coaxial cable from the plug in card to the Model 7008 Series EMField Generator and connect a coaxial cable from a RF signal generator to the RF input of the plug in card Please note that the maximum field is reached at an input power between 10 dBm and 0 dBm depending on the freguency response and attenuation of the N type cable used Make sure that the remote interlock connection of the EMCenter is closed Plug the mains cords into the mains inlet of the EMCenter an
Download Pdf Manuals
Related Search
Related Contents
LA SIESTA ALABAMA Descargar PDF American Standard 2742.428 User's Manual Operating Instructions - Manuals, Specs & Warranty DENIER DU CULTE - La Pastourelle Télécharger le Dossier de Presse Le leader mondial du rire thérapeutique Le leader mondial du rire Manuel d`utilisation Copyright © All rights reserved.