1. WinClient Remote Manager Version 2 5 swag View Help Add IP Address Range mp starting IP Adress Ending IP Address 1 fg 1 1 1 1 1 1 1 254 Pe IO Lon ll 192 168 1 254 Password Exit 7 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 emote Manager 2 5 For Windows XP Embedded Notice some functions are grey out this is because that particular function can not be used at the moment and It is disabled The sub function will become available again when the function can be executed 4 1 Add IP Address Range Add IP Address Range t To add or change an IP address range IP Address Range Staritng IP Address Ending IF Address o Key in an IP Range where WinClient is located on the network then press OK to submit After IP Range is successfully submitted now is the time to search that IP range to locate WinClients Please refer to section for more detail on the Refresh search command 4 2 Change IP Address Range View Help Change IP Address Range Change IP adress Range 3 3 To add or change an IF address range IP Address Range Staritng IP Address 132 16 Refresh Ending IF Address Delete Password Cancel Exit To make changes on a previously made IP Range first select a range listed under Information Panel then select the Change IP address range under the Action 8 WinClient Remote Manager USER S MANUAL Revision W
2. USER S MANUAL Revision WRM 2 5 2004 11 22 WinClient Remote 1 For flanager 2 5 Windows XP Embedded Client 1 Select a XPe by IP address Go to Function Bar gt Action gt Terminal Properties Setup Login with Administrator Click on Administrative Management tab Select Component Update WEE ey Component Update Dialog A7 Set component update information with this Winclient Component Server Hostname Polling Behavior Allow this dert to poll with others at the same time e Enable C Disable Polling Tima Interval Hau Friday Every 4 ll Hourtz Stary time M e Hostname Server that is running the WinClient Remote Manager and www service 6 If default setting was used then on every Friday at 8AM once every 4 hours WinClient will automatically search the host server for updates 14 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 For Windows XP Embedded 4 6 Download Configuration View Help Action wiew Help IF Address Range LLLI Download Configuration 192 168 1 1 C3 MAT Address s Configuration o TL 600 P E Platform Type E Windows CE Delete i ER Windows De Password E Group E Others Exit z This function is used to download a pre configured configuration file on to multiple WinClients Please follow the steps below for instructions 1 Go to Action and select Download Configur
3. 5 For Windows XP Embedded 1 Introduction WRM WinClient Remote Manager is a system management tool that can be used to manage AXUS WinClient series In order to achieve the ideal goal of simplifying our Computing environment AXUS Microsystems Inc designed WRM to help administrators to serve more users effectively WinClient Remote Manager acts as a central management tool for its WinClient products networking Administrators could help the users to operate his her WinClients remotely effortlessly and centrally Its friendly graphic interface not only enable administrators to learn the course within 10 minutes but also provide its user with comfortable functionalities of IP manager configuration manager F W manager and wakeup on LAN In addition WinClient refresh support helps administrators to offer real time service to all end users 1 1 Features 1 Discover WinClients on the network Easy to manage or control the WinClients on remote site 2 Upgrade firmware of multiple of WinClient Remotely 3 Upgrade Windows components to single multiple WinClients 4 Upload user preference configuration file to WinClients and manually configure preference remotely 5 Download user preference configuration files from WinClients for later use Power on clients remotely Power down clients remotely Configure client s ICA RDP remotely Setup client s domain certificate remotely ee E 1 2 System Requirem
4. 5 2004 11 22 AXUS WinClient Remote Manager 2 5 For Windows XP Embedded 7 This page is used to configure what programs you wish to start when the connection first got connected Placing a check in the box will enable this function Program path and file name ooo Start in the following folder Kee lt Back Cancel 8 This screen will allows administrator to select the type of connection is used on the WinClients Experience Performance S Choose your connection speed to optimize performance a Modem 56 Kbps v LAN OO Mbps or higher Custom R F Menu and window animation Iw Themes Iw Bitmap caching jw Reconnect if connection is dropped lt Back Cancel 9 Congratulation You have successfully setup a RDP connection on the WinClient 25 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 Kor Windows XP Embedded b ICA Connection 1 Double click on the ICA connection and you will see the following window Citirx ICA Chent Server IP Address Edit Remove Exit 2 Click on Add to build a new ICA connection This wizard will help wou set up a new Connection ICA connection Select the type of connection you will use For the new Custom Goolicatian Local Area Webwork 3 Two choices will appear One is Local Area Network and the other one is Wide Area Network Please select one that
5. Embedded 7 Detail Information Panel IP Address MAC Address Model Name Build Version Platform version Platform Mame Group eh 1 1 1 141 OO60 b3 72 e0 0e COEM 04699270K51 TC 800 P 256 Fe 5P 1 0 Pe Windows Pe EN Ae Detailed information on WinClient at a giving IP range will be displayed on this panel The following are information on the Detail Information Panel IP Address MAC Address Terminal Name Model Name Disk Size Build Version Platform type Country Contact Group IP Address A range of IP was used to search to locate this WinClient on the network Many functions of the WinClient Remote Manager require the IP Address to operate MAC Address The MAC Address will locate next to its corresponding IP Address MAC Address is often use with the function wake on LAN Terminal Name Name assigned to the WinClient to be better recognized on the network Model Name The model name of this WinClient assigned by the vendor Disk Size size of DOM installed on this WinClient Build Version Firmware Version Couniry Language used on the XPe Group Group which this XPe joined under for easier management 33 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22
6. File Name Back Net Cancel Just browse to the certificate and click on next to setup the certificate 29 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 ew ows XP Embedded 4 13 Delete View Help Platform Type 200 30 aa8 00 60 7b WOO607B Windows CE 200 30 aa 00 02 b0 OEM SEW2THSVET Windows Pe OEM 9OCHRSE FFC Windows Pe EE WODG238 Windows CE 00 30 OEM 7 MISLI W oL Windows Fe 200 30 4a8 00 46 5b WOCH Windows CE 2 00 0c 76 ae bS 15 OEM Mey2OTFS2D Windows Pe SOO SO aa 005261 OEM Mey2OTFSe2D Windows Pe Delete Password Exit The Delete function can be used to remove an IP Range or MAC address 4 14 Password View Help m AAC Address 200 30 34 00 6560 Zb WU Zb DOO 20 aart D2bt OEM SEWZIHZYKT Op 20 aart bae OEM SOCHRSEFFCI lU 30 ae8 00 62 3b WOO62 36 EAEE OEM XFMISLIWOYL UD 201 aa D d r Eh UU Ze Bou De 2eraebpip OEM MZYZOTFSZD BO0 30 aa00 52 61 OEM MZYZOTFSZDY Wakeup On LAN Delete Password Exit Password function is used to set the default login password to the WinClient Remote Manager Users have the options of enable or disable password check of WinClient Remote Manager at startup 30 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 For Windows XP Embedded 5 Tool Bar Tool Bar has similar f
7. Regional Upload regional settings such as language display date currency sign and etc Internet Option Default page setup system Enable Remote Desktop Connection and Workgroup settings Group List Upload a pre configured group list to the winclient User Account Upload a pre configured user list to the winclient Connection Upload a pre configured connection onto the winclient Such connection may include RDP ICA Power Term optional connections Component Client To set the poling time component update server name VNC Enable or disable VNC for remote monitoring After all the options are carefully selected please choose a unique name to save the file This file can be later used to configure single or multiple WinClients by using Download Configuration command Download Configuration command will be explained into full detail at the next section 4 5 11 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClhi emote Manager 2 5 For Windows XP Em bedded 4 5 Update Component Action wiew Help Platform Type ARES CE Update Component Certificate Setup Password Exit Axus will regularly release Component Updates to fix known security issues new features will be added and drivers updates In order to setup automatically polling we must configure the server side and the client side Please follow the example given below to configure your WinClie
8. AXUS WinClient Remote Manager 2 5 For Windows XP Embedded Windows Remote Manager 2 5 For Windows XP Embedded User Manual WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 For Windows XP Embedded Copyright This manual and any accompanying software and firmware are copyrighted No parts of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopy recording or otherwise without prior written consent except for copies retained by the purchaser for backup purposes Trademarks Product and company names mentioned in this manual are for identification purposes only and may be trademarks of their respective companies Microsoft and Windows are registered trademarks of Microsoft Corporation ICA Client and MetaFrame Server are registered trademarks of Citrix Systems Inc Disclaimer The information described in this manual is intended for instructional purposes only The Vendor reserves the right to revise this manual and all accompany software firmware without obligation to notify any person or organization of the revision or change The Vendor accepts no responsibility or liability for errors or misleading information that may be contained in this manual Notice The changes or modifications not expressly approved by the party responsible for compliance could void the user s autho
9. RM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 For Windows XP Embedded 4 3 Upgrade Firmware View Help Upgrade Firmware LN Set the information For firmware upgrade Upgrade Firmware Configure Upgrade Information Upload Configuration PSE Server IP EE EE Firmware Pathname backup xpe v2 sl Power OT Username administrator Refresh Terminal Properties Setup Password eg Connections Setup eer Uganda LA Sech cel Password E OK Cancel Axus will irregularly release new firmware to patch the previous released To update firmware of your WinClient remotely please use the upgrade firmware function provided by WinClient Remote Manager 2 5 Upgrade function could be used to upgrade one or multiple WinClinents locate on different location Now let s take a look at the Upgrade Firmware image and refer to below for each field s explanation PXE Server IP IP Address of the PXE Server Firmware Pathname Share folder name firmware image name Username authorized user to the shared folder Password Password of the authorize user to the share folder Boot Image Browse to find the boot image normally will be call something ramdisk Note Firmware and ramdisk can be found on the CD comes with your WinClient or can be downloaded from AXUS s FTP site 9 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 Kor Windows XP Embedded 4 4 Upload Co
10. and click on next This application you are connecting to is configured with default display options IF you would like to override these defaults you can do so below Enable Sound Use Default tedium sound quality Window Colors Use Default True Colorfe4 bit Window Size Use Default e40 A 450 lt Back Cancel 8 Enter the name of particular application on the server to run when connected or you will have the option to leave this part blank 9 Congratulation You have successfully setup a ICA connection on the WinClient 28 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient emote Manager 2 5 For Windows XP Embedded 4 12 Certificate Setup View Help Add IF Address Range Change IP Adress Range Upgrade Firmware Upload Configuration Update Component ownload Configuration Wakeup On LAN Power OFF Refresh Terminal Properties Setup Connections Setup Certificate Setup Delete Password Exit MAC Address lag Configuration HIT To enable the Certificate Setup selection first search an IP range to locate all the WinClient units After the search is completed click on the Platform Type and then select Windows XPe to the right Now under Action Certificate Setup will be enabled and ready to be used Certificate Import Wizard File to Import Specify the file wou want to import
11. as able to locate two WinClients within this IP range Please note that before any command can be issued to the WinClient by the WinClient Remote Manager a search must be preformed and WinClient s IP must appear in the Detail Information Panel 17 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 For Windows XP Embedded 4 10 Terminal Properties Setup ID Address Mac Address Terminal Mame View Hel P DO 30 aa 00 62 3b WOO 36 OO 207 aa 00 52 61 OEM Mey20TF Upgrade Firmware Upload Configuration Account Type ug Administrator Administrator BR user Private User Power OFF Refresh Terminal Properties Setup Connections Setup Password Exit Terminal Properties Setup is used to setup single WinClient s properties This function can be used without a pre configured configuration file One downside of this function is only capable of configuring one terminal at atime Follow the procedures below for the proper usage of this function 1 Search for a WinClient from the IP Range 2 Select the IP where the WinClient resides and wish to be configured 3 After IP is selected go to Action and choose Terminal Properties Setup d Login with an Administrative account Key in Administrator s password and notice the Save Password For this account If you want WinClient Remote Manager to memorize this set of password for this particular u
12. ation file 2 Goto Information Panel and select a TC 600XP under Configuration 3 Go to Configuration Name and select a file In this example we are going to use a pre configured file named test d Now go to Action and select Download Configuration again 5 The following screen will appear after download configuration is clicked Configuration s File test Model Mame TC 600 P Build version be bi Platform version be Build Version Terminal Mame IP Address BPE SP1 0 DEM MZYZQTFS 1 1 1 141 kS gt cercel 6 You may select more then one WinClient by using this download configuration function 15 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 For Windows XP Embedded 4 7 Wake on LAN View Help AAC Address Platform Type D00 30 4a 00 60 7b WOO6O7B Windows CE S OO 30 aa 00 02 60 OEM SEWZIHZVET 4 Windows Pe 0030460052 61 OEM 90 ARSE FFE Windows Pe vera Bo0 30 aa 00 62 3b WO0623B Windows CE OU S30 aa 00 62 63 OEM MISLI W YL Windows be SE WOOGCHA Windows CE DD DC 76 ae 65 15 OEM Mey2ZOTFS2D Windows Pe OEM Pe2yY2OTFSZD Windows Pe Delete Password Exit The Wake on LAN function is used to power on WinClient who is at off state Please note that in order for Window Remote Manager to power ona WinClient through network that particular WinClient s MAC address must be in the MAC address fiel
13. best fit your needs and click on next 26 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 Kor Windows XP Embedded d Enter a name for your connection select a network protocol and type in the name or IP of the server to connect and click on next Connection Enter a description For the new ICA Connection Select the network protocol thak your computer will use to communicate with the server Farm rei HTTF Select the MetaFrame Presentation Server computer or published application to which you wank to connect Is Server Published Application lt Back Cancel 5 Select an encryption level and click on next Encryption Select the desired encryption level and whether or not ta use session reliability For this connection Encription Level Basic h Session reliablity W Enable lt Back Cancel 21I WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 Kor Windows XP Embedded 6 Type in user name and domain if available and click on next Logon Information Enter a User name Password and Domain to use with this Connection If you leave these fields blank you will be prompted For this information when you connect User name axus Domain lt Back Cancel 7 Uncheck the use default check box to customize the display settings
14. d If you don t see the WinClient s MAC address in the MAC address field please manually power on the WinClient and search the IP range again for WinClient Once the WinClient has been identified by the search function then you will see that particular WinClient s MAC address in the MAC address field Once you are able to locate the MAC address select the MAC address and click on Wake on LAN 16 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 For Windows XP Embedded 4 8 Power Off view Help Upgrade Firmware Upload Configuration IF Address MAC Address O0 30 aa 00 62 3b ml 11141 O0 30 aa 00 52 61 Power OFF Refresh Terminal Properties Setup Connections Setup Password Exit To Power Off a WinClient through WinClient Remote Manager first by selecting the IP address located on the Detail Information Panel then Click on Action and select Power Off 4 9 Refresh View Help Upgrade Firmware Upload Configuration IP Address MAC Address Terminal Mame Wii 00 30 4a 00 62 3b WOOG2 36 eeitt 11 141 00 30 aa 005261 QEM MZV ZOTFS2D Power OFF Refresh Terminal Properties Setup Connections Setup Password Exit The Refresh command is the same as search To search an IP range for existing WinClient this command will need to be used In the above example we set the IP range as 1 1 1 1 to 1 1 1 254 and WinClient Remote Manager w
15. e Model Name i 00 30 aa 00 62 3b WOO623B TC 600 E Power OFF E 11 120 00 30 aa 00 62 63 OEM MZYZOTFSZDY TC SOND Refresh O0 60 b3 72 e0 0e OEM 04699270K31 TC 6008P Terminal Properties Setup Connections Setup Password Exit Connections setup is used to manage remote WinClient s connection through WinClient Remote Manager The Connection consists of ICA connection and Remote Desktop Connection Follow the steps below to properly manage your WinClients 1 Perform a search on an IP Range 2 After Search WinClient Remote Manager will locate a list of IP addresses Select the IP address of the WinClient needed to be configure then go to the Function Bar gt Action gt Connections setup Account Type ve Administrator Administrator Private User Log On to Remote Client e2 User name Administrator Password ed Save password For this account en 3 Key in Administrator s password and notice the Save Password For this account If you want WinClient Remote Manager to memorize this set of password for this particular user on this WinClient then have this box checked 22 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 For Windows XP Embedded 4 The next popup window will display two types of connections One is RDP and the other one will be ICA connection First let us take a look at RDP connection Connecti
16. ents Recommended OS environment Microsoft Windows 2000 amp 2003 Server series with IIS Applied OS Microsoft Windows XP Profession Microsoft Windows NT Terminal Server 4 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 For Windows XP Embedded 2 How to install WinClient Remote Manager Contact your WinClient vender to acquire WRM software and follow the steps below to complete your installation 1 Copy the WRM zip file to your server hard disk directory for example C WRM 2 Locate the file and double click WRM_V2 5_setup zip file to extract the zipped files 3 Run the Setup program and the installation wizard will pop up Follow the steps to proceed with the installation 4 After finishing installation a shortcut will be created on your desktop and Start menu Notice If you cannot install WRM directly by double clicking the WRM setup file you probably need to use Add Remove Program function in the control panel to install it Using Add Remove Program 1 Installation Follow 1 3 steps above to uncompress the zip file to produce a SETUP executable file Afterwards go to Start Menu gt Control Panel double click on Add Remove Program Add New Programs gt Select From CD ROM or Disk click on Next button click on Browse select the location where SETUP file locate and then go through the setup procedures However if you still have trouble install
17. ing WRM application please contact your vendor to solve this issue 2 If you want to remove this application please also use Add Remove programs function to uninstall it 5 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 For Windows XP Embedded 3 Window Remote Manager Overview elt a WinClient Remote Manager Version 2 5 Action View Help le SCH ro IF Address Range IP Address MAC Address Model Name Disk Size J my 1 1 1 1 4192 168 1 151 0030 aa 005260 MEM 9QCHRSEYFCI TC 600 P Go MAC Address s Configuration Ss Tc 600xF 192 168 1 152 192 168 1 171 192 168 1 50 DO 20 aa 00 02 b OOS sO aa 00 62 65 DO 20 aa 00 60 zb OEM SEWZIHEVET TC 600 P WiOOS26 1 TC 600VE WUUGU 7B TC 80SNE B Platform Type K Windows CE Se Windows Pe Group Others 3 1 Function Bar a WinClient Remote Manager Version 2 5 4ction View Help Function bar is where most functions are located However these functions will also be in the Tool bar which we will go over in the later section 3 2 Tool Bar a E KY Tool Bar has similar functions as the function bar The main differences between these two menu are one is with pictures and one is without pictures Tool Bar can also be explained as a quick lunch bar With easy to see and self explanatory pictures using WinClient Remote Manager is never easier All the function of
18. nfiguration View Help Account Type Upgrade Firmware ead Administrator Administrator Upload Configuration Private User Power OFF Refresh Terminal Properties Setup Connections Setup Password Exit Upload Configuration is used to upload a pre configuration file onto the Window Remote Manager and later to be downloaded to other Winclient s After choosing administrative account you will be prompted to key in password for that particular account Few scripts will run after password has been keyed in and the following will appear on your screen Upload Configuration UserName Administrator ModalName TC 600 P PlatformYersion Pe IF 1 1 1 141 Configuration Item Description Display L keyboard IT Mouse IT Power L volume L Regional 0O InternebOption D1 system lt The upload configuration options are Display Keyboard Mouse Power Volume Regional Internet Option System Group List User Account Connections Component Client VNC 10 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 For Windows XP Embedded 4 4 1 Configuration Options Explained Display Upload configuration on the screen resolution and color KeyBoard Upload Keyboard properties such as Character repeat speed and Cursor blink rate Power Upload power option properties to save energy Volume Upload pre configured volume settings
19. nt network Server 1 First Click on Platform on the Information Panel then on the Detailed Information Panel and select Windows XPe 2 Now select Update Component on the Function Bar under Action 3 The following screen will appear Information 1 i WindClient Remote Manager can t Find the QFE initial File Press OK to select it or Press Cancel to give up configuring component update e 4 Now click on OK to manually locate the file under your wwwroot Note you must copy the unzipped update component file into wwwroot xpeqfe web server directory 12 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 For Windows XP Embedded 5 Now you must tell WinClient Remote Manager which directory your web server is located under 6 Click on OK to continue Browse For Folder Select Web Server Home Directory E LC Inetpub CH AdminScripts i Ftproot mailroot E wart Update Component Configurate Ke Set component update i om Configure Update Information Component Hostname Dal WebServer Home C Vpetoubuawroot EA Directory Component Directory netpub wwmr oot xpeqfe QU002 OK Cancel Note Whenever there is a new update available please repeat steps 1 to 5 to add the component Note The directory name xpeqfe Q000x must be the same as example given 13 WinClient Remote Manager
20. on List Microsoft Citir ICA Remote De Client OK a RDP Connection 1 Double click on the Microsoft Remote Desktop connection and you will see the following window Microsoft Remote Desktop Client Server IP Address 2 23 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 For Windows XP Embedded 3 After Connection Name Computer User Name Domain if needed has been key in then click on next 4 The next screen will be for the display settings Remote desktop size i Choose the size of your remote desktop Drag the sider O all the way to the right to go full screen 640 by 480 pixels Colors C High Cool bit e Note Settings on the remote computer might override the setting l Display the connection ball lt Back Cancel 5 Select the Resolution by moving the cursor to desire location and select the color 16bit recommended and click on next 6 The next screen will be resource page Local Resources Remote Computer Sound P w SE Bring to this computer Saa Keuboadk Apply Windows key combinations for example ALT TAB On the remote computer SS Local Devices GH Connect automatically to these local devices when logged GP on to the remote computer Disk divers Printers Serial ports Smart cards lt Back Cancel 24 WinClient Remote Manager USER S MANUAL Revision WRM 2
21. rity to operate the equipment 2 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 For Windows XP Embedded 1 ge Te E d e Ge 4 UR E UR IM NU a corre erence waar EAEE r aT EETA IEA EEEE 4 2 How to install WinClient Remote Manager scccssssssssscccscccsssssssees 5 3 Window Remote Manager Overview ssssscssscccrsssssssssssscccccscssssssssees 6 MSE nee re EE 6 De MOGI EE 6 De MONO ee PAM Cy E 7 Ore ICT ad MPO ri ae On ANC Ue once sine cease E EE 7 4 Using D Te et E 7 e Add IPF Address EE 8 42 mane Ol Address AIC cdcicadexesestsnctesanconsseasaacnreatdonswesdiantesineonesieeaacnstandoeannoteued 8 GM Be NR GE 9 AA NNO AG e EE e EE 10 4 4 1 Configuration Options Explained ssesssseeeenssssssssoeeeesssssssseeeres 11 d UP EE 12 460 Download C Omit E cee oes cess testo srece EE TEE EE E 15 Ae Wane OnE ME 16 BE OW Ci O GE 17 aE E 17 A10 Terminal Properties SetU P eege 18 AOE el 20 4 10 2 Administrative Management 21 EE Ee 22 GN DE E o e r E E E E AE 29 GN ER 30 GN E FASS Vy E 30 5 Tool Dar caie sce sicet assure T T 31 6 l tormaton Panel sssrinin rane r n 31 6 1 Information Panel Main Categories 31 6 1 1 Paade EE 31 6 1 2 E ele 32 6 1 3 Oon UN AL e a A EEE EAI E AT 32 6 1 4 POr Kon 32 6 1 5 O EE 32 7 Detail Information Panel 33 WinClient Remote We USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2
22. rnet Explore Keyboard properties can be configure and send to the WinClient To control the speed of cursor movement and click speed of the mouse To configure the IP address of the WinClient To remotely configuring the power scheme on the WinClient To localize WinClient to fit the regional settings such as language Keyboard Mapping Etc To Change the default volume level of the WinClient 20 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 bor Windows XP Embedded 4 10 2 Administrative Management Ramdisk A 33 Automatic Logon T System User Accounts Ai Component Update LS N C VIN Set the RamDisk size on the WinClient The storage space on the Ramdisk came from C Configure default logon user Remotely change computer of the WinClient and configure WinClient to allow remote desktop connection Basic system information is also shown here Remotely add and delete user change user s access level and group Remotely change the update server settings and time interval of polling Enable or disable VNC startup by default 21 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 For Windows XP Embedded 4 11 Connections Setup View Help Upgrade Firmware Upload Configuration IP Address MAC ddress Terminal Mam
23. ser on this WinClient then have this box checked Administrator Private User Log On to Remote Client User name Administrator Password Save password for this account Cancel 18 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 Kor Windows XP Embedded 5 Let s look at the Control Panel first then Administrative Management Terminal Properties Control Pannel Administrative Management g S 9 e Date Time Display Internet Keyboard Option e 4 9 Network Power Option Regional and Volume Settings Language Settings Set the date time and time zone information Terminal Properties Control Panne Administrative Management G 3 w 8 g Famdisk Automatic System User Accounts Component Logon Update VD Cc WK Pick a Function 19 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 4 10 1 9 Date Time a d r Display wheats ger Internet Option Keyboard Network Settings f m ba Power Option E A Regional and Language D volume Settings AXUS WinClient Remote Manager 2 5 For Windows XP Embedded Control Panel To configure the date time and time zone of the WinClient Display settings includes color resolution screen refresh rate and screen saver All can be configured To set the default page for WinClient s Inte
24. tegory is used with function Refresh 31 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 For Windows XP Embedded 6 1 2 MAC Address Displays all the MAC addresses of WinClient have ever been found by the WinClient Remote Manager currently connected and currently offline will all be shown Used with most of the function on Function Tool Bar 6 1 3 Configuration This category will display two different types of configuration One is configuration used on WinCe another type of configuration is for Windows XPe This category must be in use with Upload amp Download configuration function 6 1 4 Platform Type This category will display two different types of platform One is platform WinCe another type is Windows XPe This category is used with function Update Component and Certificate Setup 6 1 5 Group This category is very important on the managing the WinClient network For example a network of WinClient consisted of 100 units For easier management administrator would need to group similar clients together This is done by single click on the group others then a list of IP will appear on the right Right mouse click a single IP and two choices will appear One is to move them into a new group or move them into an exiting group 32 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 For Windows XP
25. the tool bar will be explained at later sections 6 WinClient Remote Manager USER S MANUAL Revision WRM 2 5 2004 11 22 AXUS WinClient Remote Manager 2 5 For Windows XP Embedded 3 3 Information Panel mj IF Address Range 1 1 1 1 With the helps of Information Panel administrating sop 192 160 1 1 a complex WinClient network is now painless and Ea MAC Address J Configuration easy to manage All the information needed to Te TC BOOKP administrate is ata glance IP range available to Platform Type oo Se Windows CE search for Winclient Mac address of each 2 Windows be WinClient type of OS used by the WinClient and Group oa BY others group all can be viewed by using this function 3 4 Detail Information Panel IP Address MAZ Address Terminal Name Model Name Disk Size i92 165 1 151 00 30 aa 00 52 60 OEM 9OCHRSEFYFCI T_ 600 P 126 a 192 168 1 152 00 30 33 00 02 b0 OEM GEWeTIHAVET TC 600 P 126 al 192 168 1 171 DU 20 ae 006263 WOO5261 T B00VE 16 a 192 168 1 50 00 30 33 00 60 7b w000 E TC 805NE 16 This panel will display detail information of the Information Panel For example by clicking on the IP range 192 168 1 1 then all the Winclient within that particular IP range will be displayed 4 Using Function Bar Function Bar is made up by the following components Action View and Help Each of these components is made up by sub functions Let s look at component Action for example
26. unctions as the Function Bar The main differences between these two menu are one is with pictures and one is without pictures Tool Bar can also be explained as a quick lunch bar With easy to see and self explanatory pictures using WinClient Remote Manager is never easier For help and explanations of the function on the each item please refer to section 4 6 Information Panel mj IF Address Range i 1 1 1 Sal 192 165 1 1 The Information Panel helps administrators organize Z MAC Address network information by dividing network information into Configuration categories 5 TC 600KF i I Platform Type Most functions from the Function Bar or the Tool Bar must e windows CE e i Be ina cede combine usage with the information panel for proper Group functioning Okhers In another word one could say the Information Panel and the Function Bar are what made WinClient Remote Manager 6 1 Information Panel Main Categories since wide ranges of data are all gather by the Information Panel displaying this information without categories is nearly impossible Axus took the liberty and divided this information into four categories and made WinClient Remote Manager even more powerful The main categories are as follows 1 IP Address Range 2 MAC Address 3 Configuration 4 Platform Type 5 Group 6 1 1 IP Address Range Displays different ranges of IP were added to search the network for existing WinClient This ca