Home
Horizontal Inclinometer Probe
Contents
1. HORIZONTAL INCLINOMETER PROBE User Manual Horizontal Inclinometer Probe INDEX Introduction Pag 4 Description Pag 5 Taking measurements Pag 6 Data processing Pag 8 Maintenance Pag 10 Troubleshooting Pag 10 Maintenance service Pag 11 Appendix 1 Pag 12 Appendix 2 Pag 13 Information contained herein are property of SISGEO S r l This document is subject to change without notification and is subject to be returned upon request No part of this User s Manual may be reproduced in any form without SISGEO S S r l written permission SISGEO S r l Horizontal Inclinometer Probe EN 00 12 Pag 2 of 13 Notes on the use of product Symbols Identification SISGEO S r l Horizontal Inclinometer Probe For a safe and efficient use of the instrument please read carefully the following instructions before starting any operation Any use of the instrument other then the one described in this manual shall be considered at user s full responsibility The same applies for any unauthorized modifications In addition to the hereby listed standards the user must comply with the provisions of the current legislation on the matter of personal safety and health of persons in the workplace SISGEO is not responsible for any trouble breakdowns accidents etc due to the lack of knowledge and or confidence or non compliance with with the requirements contained in this manual Check that the instrument has not been
2. Horizontal Inclinometer Probe The data processing is usually made using a dedicated software i e FIELD SISGEO INCLI2 see the reference manual for further details Herewith below are clarified the basic notions for data processing SISGEO inclinometer probes have a constant k of 20000 Different k shall be required at order placing The values digits displayed from SISGEO dataloggers are digits sina x k Example Ch A 698 digits a arcsin 698 20000 2 To calculate the casing inclination at each quote proceed with the following formula D P x sind where D casing displacements at the generic quote P measurement step sina casing inclination angle at the generic quote The inclination value for each measuring step is A1 A3 2 Example G At i quote we have the following values A1 480 A3 506 P 500mm The inclination at the i quote is 12 325mm To calculate the global displacement D of the casing proceed with the following formula Horizontal inclinometer probe EN 00 12 Page 8 of 13 SISGEO S r l Horizontal Inclinometer Probe The global displacement calculation must be done considering that one of the end of the casing is not subject to movements or considering the absolute displacements of the casing taken for example by means of topographic measurements Hints on checksum The checksum is the algebraic half sum of the measurements obtained on the m
3. cable has metal marks every 500mm The first mark is 1m far from the middle of the probe wheel assemblies Every 5m a colored reference tape identifies the distance position see Appendix 2 Yellow cable is suitable for both servo accelerometer and MEMS digital probes It is reinforced with a stainless steel shield in order to avoid torsions and elongations Orange cable designed for the MEMS probe is lighter and easy to handle It has a kevlar stress member in order to avoid elongation wheel assemblies electric connector es inclonometer cable connector cable connector with O Ring Horizontal inclinometer probe EN 00 12 Page 5 of 13 Taking measurements SISGEO S r l Horizontal Inclinometer Probe The inclinometer reading consists in a survey at regular steps of the inclinometer casing tilt compared to the horizontal The step is usually the same of the wheels assembly interaxis or a multiple The first reading called zero reading is the reference reading compared to which all the displacements of the inclinometer casing will be calculated the following readings are called exercise readings The following drawing shows the convention Reference 1 if wheels saut Reference 1 wheels Install the inclinometer casing with the groove 1 and 3 in vertical position compared to the 2 supporting surface To carry out inclinometer measurements proceed as follows Remov
4. damaged during the transport Verify that the package includes all items as well as any requested optional accessories if anything is missing please promptly contact the manufacturer The user must strictly follow all the operations described in this manual Maintenance or repair of the instrument is allowed only to authorized operators These operators must be physically and intellectually suitable For information about instrument or order spare parts request please always specify data written on the identification label When replacing parts always use ORIGINAL SPARE PARTS The manufacturer reserves the right to make changes without prior notice for any technical or commercial requests We ll try anyway to keep the manuals updated in order to reflect product s revisions updates This symbol will be used used to catch reader s attention on the manual Pay special attention to the following instruction Instruments can be identified From a production lot number written on the Compliance Certificate From a serial number s n engraved indelibly on the instrument e From a label on the instrument From a label on the cable Horizontal Inclinometer Probe EN 00 12 Pag 3 of 13 Introduction SISGEO S r l Horizontal Inclinometer Probe The horizontal inclinometer probes are used to measure settlements and vertical deformations They are used mainly in foundations embankments and tanks Inclinometer probe is a par
5. one TT Te BLUE GREEN SHIELD FLYING CABLE MOD ECAVO7V2 Female Connector at the cable pulley Male Connector to Datalogger SISGEO S r l Horizontal inclinometer probe EN 00 12 Page 12 of 13 Horizontal Inclinometer Probe REFERENCE MARKS Appendice 2 WHITE Oo in qT N METERS Page 13 of 13 EN 00 12 Horizontal inclinometer probe SISGEO S r l
6. atched grooves 1 3 It s like an electric and or mechanic offset of the inclinometer probe and as shown in the following example does not affect the final result it is a sign of the well functioning of the inclinometer system and its regular check is important The checksum can be affected by deposits in the grooves by inclinometer casing dents or ovalization from the wheel positioning near the couplings and also by the differences between different models of Dataloggers Checksum value can change in time but if the variation is not sudden usually there is nothing to worry and is not necessary to contact SISGEO for technical assistance Anyway SISGEO suggests a check of the inclinometer system in case of checksum values higher than 25 Example inclination 2 theoretical value 698 digits Al 713 A3 683 checksum A1 A3 2 15 Ai checksum 713 15 698 A3 checksum 698 15 698 Anyway the value obtained by the matching measures at the end of the processing is Am A1 A3 2 713 683 2 698 Horizontal inclinometer probe EN 00 12 Page 9 of 13 Maintainance Troubleshooting SISGEO S r l Horizontal Inclinometer Probe Probe maintainance The inclinometer probe is a precision instrument and has to be handled carefully avoiding accidental shocks both during the transport and the use Use the carrying case during the transport and the storage Clean the probe with water and lubricate the wheels and
7. e the probe from the carrying bag Check the wheels assembly and the wheels functionality Check the O ring Keep the probe in vertical position on the ground and connect the inclinometer cable to the connector 1 paying attention to fit the connector references DON T TURN and DON T STRAIN the connectors in order to avoid any irreparable damages Once the connectors are matched screw manually the nut until is fully locked If well connected the tightness is guaranteed up to 2MPa Connect the steel wire to the steel cap on the connector 2 Put the probe into the inclinometer casing with the reference wheels in the groove no 1 Position the probe at the end of the casing using the steel wire Connect the datalogger to the inclinometer cable with the supplied connector Be careful to respect the connectors polarity Horizontal inclinometer probe EN 00 12 Page 6 of 13 SISGEO S r l Horizontal Inclinometer Probe Switch on the datalogger and wait for 10 15 minutes until the temperature stabilization Pull the probe until the first available mark is at the border of the inclinometer casing Place very carefully the marks since in order to have good results their position must never change Wait until the value stabilization identified as A1 and record this value Pull the probe placing the next mark at the reference point according to the step set Proceed in this way for the whole length of the casing Once end
8. ed pull out the probe from the casing and disconnect the moving wire Disconnect the inclinometer cable from the connector 1 and connect it to the connector 2 Connect the steel wire to the steel cap and screw it on the connector 1 Put the probe into the inclinometer casing with reference wheels in the groove no 1 and position it at the end of the casing using the steel wire Proceed as already explained above In this case the values will be identified as A3 Once ended the reading disconnect the datalogger unscrew the nut and disconnect the probe from the inclinometer cable Check the connectors probe and cable be sure that there is no humidity inside Screw the protection caps Clean and dry the probe carefully Put the probe in its carrying casing Rewind carefully the inclinometer cable on the reel avoiding any torsion Advices Use always the same inclinometer system probe datalogger cable to Survey the casing Pay attention to the reference points marks Wait until the inclinometer system temperature is stable it could be useful in this case to check the values shown by the datalogger When you move from a quote to the next one record the data only when the values are settled In case of wrong positioning put the probe at the previous position Avoid pulls and excessive speed during the probe recovery Horizontal inclinometer probe EN 00 12 Page 7 of 13 Data processing SISGEO S r l
9. ify wheels movement If necessary send back to SISGEO Assistance Excessive movement of the wheels Checksum Verify and insert correctly the values Wheels out of grooves wheels in the grooves unsteady Move the probe more slowly Dirty casing Clean the casing Horizontal inclinometer probe EN 00 12 Page 10 of 13 Maintainance service SISGEO S r l Horizontal Inclinometer Probe After sales assistance on SISGEO products for calibrations maintenance and repairs is performed by SISGEO service department The authorization of shipment shall be activated by RMA Return Manufacturer Authorization Fill in the RMA module clicking on http Www sisgeo com en assistance repairs Send back the instrument equipment with the complete accessories using suitable packaging or even better the original ones The shipping costs shall be covered by the sender Please send the goods to the following address with suitable delivery document SISGEO S r l Via F Serpero 4 F1 20060 MASATE MI On the delivery note is mandatory to indicate the received RMA code Technical assistance e mail assistance sisgeo com Horizontal inclinometer probe EN 00 12 Page 11 of 13 Horizontal Inclinometer Probe Appendix 1 CONNECTION TABLE MEMS DIGITAL PROBE Inclinometer cable orange Conn 6 pins Color Conn 7 pins Female Male Panel O e Vcc A RED RS485 A E Female Male Panel De Tuk S o f w o C a Ce Cu Ce
10. t of a system which includes e Horizontal inclinometer probe e Inclinometer cable e Portable Datalogger for data management e Incli2 data management software Measurements are usually carried out moving the probe inside inclinometer casing aluminum or ABS made The casing follows the deformations of the material where it is installed A pulley is required when one end of the casing is not accessible open in order to pull move the inclinometer probe inside the casing by means of a pulling steel wire reel and inclinometer probe inclinometer casing inclinometer cable wg ICS are DO 7X XK Ve xe rf LE NO ave REN von ae A HET DR Eg Eg PE A VE K X lt ps DK SPAIN XK S S se Zi us x Ce de LT CON Z Ay Z CS a LDS pa X hf OKA vn fan sits Ra steel wire portable datalogger pulling steel wire inclinometer casing PVC pipe Horizontal inclinometer probe EN 00 12 Page 4 of 13 Description electrical connector SISGEO S r l Horizontal Inclinometer Probe The horizontal inclinometer probe consists of a cilinder stainless steel body with digitized uniaxial MEMS tilt sensor Probe is equipped with e Two electrical connectors with O Ring 1 and 2 at each ends e Two wheel assemblies 500mm apart for guiding the probe through the grooves of the inclinometer casing The inclinometer operating cable supplied on reel mounts at one end the probe mating connector The
11. the springs without using grease Clean up the possible mud and dirt on the springs Take away the protection cap from the probe and inclinometer cable clean and eventually dry the connector and the thread Clean the connectors with cotton wads and alcohol Don t use solvents or other products that can cause a damage The probe and the accessories must be stored in a dry place To avoid condensation we advise to store probe and cable without protection caps they have to be put back on in case the instrument has to be moved Clean the inclinometer cable with water and dry it Be careful during the unwind and rewind of the cable in order to avoid stretching and rolling that can damage the cable When they are not in use always protect the connectors with their caps To keep the system in perfect conditions we advise a maintenance check in our laboratories once a year T Wrong choice of the Use the correct reference groove measures reference Check the voltage on the display Low battery voltage and put in charge see the manual Measure the insulation between the pins of the probe connector Low insulation and the steel body If it s less than 50 MQ send it Instable back to SISGEO Assistance measures Dry it Damp in the connector Verify the integrity of the O ring Verify wiring in the Appendix 1 Send back to SISGEO Assistance if any disconnection is found One or more electric wires are disconnected Ver
Download Pdf Manuals
Related Search
Related Contents
KeySonic KSK-3205 RFM 平成 22 年度 - 千葉の県立博物館 ISA96 P7/106 Technical Description Email troubleshooting: disable “Hang up after send universidade tecnológica federal do paraná departamento METROVISION - Visual field user manual florestal de santa catarina Chronique D`UN LEVER DE SOLEIL AVORTÉ ! Nilfisk-ALTO 440-M/B1 User's Manual Samsung 500万 3.0" LCD显示屏 HMX-H400BP 用户手册 Copyright © All rights reserved.