Honeywell Analytics Impact Pro User Manual
Contents
1. See manual Sensor overrange Switch instrument on and off 53 Calibration required Flammable sensor has been exposed to more than 100ppm H2S Recalibrate 54 Low O2 flam inaccurate Insufficient oxygen for the flammable sensor to operate accurately Recalibrate or fit new cartridge Impact Impact Pro Impact Pro IR Operating Instructions 76 Number Message Action or Reason 56 Switch on off to reset Faulty sensor or poor cartridge contact Remove and refit cartridge Replace suspect sensor serviceable cartridge Replace cartridge 57 Switch on off to reset Software Algorithm Error Switch instrument off and back on to clear the fault 58 Switch on off to reset Failure of the ADC has been detected Switch instrument off and back on to clear the fault If fault persists contact supplier 104 Switch on off to reset Oxygen cell fault Recalibrate or fit new cartridge 105 Switch on off to reset Flammable cell fault Possible flammable fuse broken Recalibrate or fit new cartridge 106 Switch on off to reset Toxic 1 cell fault Recalibrate or fit new cartridge 107 Switch on off to reset Toxic 2 cell fault Recalibrate or fit new cartridge 200 Switch on off to reset A generic software fault has occurred 1 Switch instrument off and back on to clear the 2 fault If fault persists contact supplier 3 Find out more www honeywellanaly
2. 3 is pressed the user should hear the distinctive click of the Enforcer gas delivery solenoid valve After about 90 seconds the instrument will display either a pass or fail 6 or OK Press to continue Enforcer Calibration Fail Press to continue Enforcer Calibration If the instrument reports a failure then check that the gas cylinder has 7 sufficient pressure Then repeat once more Note that the instrument drawer must be opened and then closed to reactivate the Enforcer If a subsequent failure should occur please have the instrument serviced and calibrated as it may be due to blocked or dirty filters or the sensor s has failed When completed and successful remove the instrument by pressing 8 downwards on the rear locking catch and lifting the instrument out The instrument will activate all its gas alarms as it detects the gas from the cylinder thereby also performing a bump test Rear Locking catch Button The cylinder should be removed after use The instrument automatically switches to a flammable gas setting of methane while in use with the Enforcer On completion it will revert to the flammable gas that the instrument is set to measure No intervention by the user is required 5 Fault Finding and Procedures There are two levels of fault within the instrument The first level is a warning from which the user may be able to recover e g a low battery The user must press the 3 button to confi
3. Impact Series Operating Instructions and Maintenance Manual Manual excerpt regarding Honeywell Enforcer use with Appendix of fault codes Impact Impact Pro Impact Pro IR Operating Instructions 45 494 Enforcer Calibration This is designed for oxygen flammable catalytic or IR LEL sensor carbon monoxide and hydrogen sulfide using a special to type gas cylinder It offers quick simple and safe operation by any user due to the use of a patented low pressure low flow rate system Note that the Enforcer cylinder contains dangerous gases Performing a Calibration Check with Enforcer To perform a calibration check of your Impact unit using the Enforcer power the unit on and place it into the Enforcer and follow the on screen instructions see Section 4 9 4 1 Enforcer On Screen Instructions Then review the peak readings as shown in Section 4 1 1 Peak Screen Performing a Bump Test with Enforcer To perform a bump test of your Impact unit using the Enforcer power the unit on then place it into the Enforcer and follow the on screen instructions See Section 4 9 4 1 Enforcer On Screen Instructions A bump test is a check of basic functionality not a calibration check so the Impact unit need not remain in the Enforcer for the full ninety seconds 30 seconds is usually sufficient Remove the Impact and check that all the fitted sensor channels are showing alarms and that the visual red flashing lights and audible alarms ar
4. e active If there is any doubt about the bump test result carry out a calibration check as described above or a full calibration as described below Performing full Calibration with Enforcer Power up the instrument and perform a hard zero using the zero on the calibration menu see Section 4 9 2 1 Zero then follow the steps in Section 4 9 4 1 If the Enforcer calibration is successful the unit will automatically update the next calibration required by date by the predefined calibration interval value default 180 days Note If the Hard Zero is omitted then the calibration is retained only for the current session and the calibration date will not be updated 4 9 4 1 Enforcer On Screen Instructions If it is not already fitted screw the Honeywell Analytics cylinder in tightly 1 multi gas mix for Enforcer check that the pressure gauge shows gas pressure is present and pull back the instrument drawer Insert the instrument by tilting at a slight angle so that the instrument 3 front cover locks under the cover lip in the Enforcer as indicated Then return the instrument to the vertical The rear locking mechanism 4 of the Enforcer will retain the instrument Now close the drawer firmly Impact Impact Pro Impact Pro IR Operating Instructions 46 The instrument will recognize the Enforcer and display an instruction to 5 press the 4 button to continue Press to continue Enforcer Calibration When
5. of the same type 13 Battery empty Check batteries Battery too low to operate instrument Recharge battery or fit new battery pack 14 Battery low Recharge battery or fit new battery pack 15 Switch on off to reset Memory error 16 Pump fault The pump is expected but not fitted The pump calibration has failed 17 Pump blocked Check and remove the blockage Check for water or dust in the sampling tube Once the above has been checked press the 3 button to restart the pump 18 See manual Memory error Incorrect firmware 19 Passed install by date Cartridge has exceeded its storage life Fitting cartridge will reduce lifetime of cartridge and affect warranty 20 See manual Cartridge not being activated Contact Service Center 21 Contact service center Memory error An instrument parameter is out of the permitted range 22 Contact service center Memory error A cartridge parameter is out of the permitted range Impact Impact Pro Impact Pro IR Operating Instructions 75 Number Message Action or Reason 23 Switch on off to reset Caused by an unexpected switch off e g poor or intermittent battery contacts Switch off instrument and switch on again 24 Please recharge or replace batteries Insufficient battery voltage to operate the Enforcer Recharge battery or replace the battery pack 25 Calibration required Recalibrate or fit new cartridge 26 See man
6. rm the warning has been seen The second level is usually non recoverable by the user and in some cases the only action available is to switch the instrument off In both cases a warning fault code number is given with a brief description of the fault and a contact name telephone number to enable the user to further assistance if required Details of the warning and fault codes are given in Appendix A Impact Impact Pro Impact Pro IR Operating Instructions 74 Appendix A A1 Fault Warning Codes Number Message Action or Reason 1 Clear log to reset Log memory error Clear the event log 2 Clear log to reset Log memory error Clear the gas log 3 See manual Memory fault 4 Insert valid cartridge Insert a valid cartridge If one is fitted remove and refit 5 Insert valid cartridge Memory error Replace cartridge 6 Insert valid cartridge An Impact instrument does not support serviceable cartridges 7 Insert valid cartridge Sensor mix incorrect Replace cartridge for the required type This is only generated if the user declines to accept the cartridge s alarm settings 8 Replace batteries Battery unchargeable Replace the battery pack 9 Cartridge expired Fit new cartridge 10 Cartridge expires in nn days Fit new cartridge 11 Calibration due Calibration is due soon Recalibrate or fit new cartridge 12 Check batteries Mixed battery types i e one dry cell one rechargeable Fit two
7. tics com Contact Honeywell Analytics Americas Honeywell Analytics 405 Barclay Boulevard Lincolnshire IL 60069 USA Tel 1 847 955 8200 Toll free 1 800 538 0363 Fax 1 847 955 8208 detectgas honeywell com Europe Middle East Africa Life Safety Distribution AG Wilstrasse 11 U11 CH 8610 Uster Switzerland Tel 41 0 44 943 4300 Fax 41 0 44 943 4398 gasdetection honeywell com Technical Services ha global service honeywell com www honeywell com Asia Pacific Honeywell Analytics Asia Pacific 508 Kolon Science Valley 1 187 10 Guro Dong Guro Gu Seoul 152 050 Korea Tel 82 0 2 2025 0307 Fax 82 0 2 2025 0329 analytics ap honeywell com 2302M5030 Rev 11 March 2008 2008 Honeywell Analytics Please Note While every effort has been made to ensure accuracy in this publication no responsibility can be accepted for errors or omissions Data may change as well as legislation and you are strongly advised to obtain copies of the most recently issued regulations standards and guidelines This publication is not intended to form the basis of a contract
8. ual Operating temperature specification exceeded Operate instrument within its specification 27 See manual Operating temperature specification exceeded Operate instrument within its specification 28 Insert valid cartridge Cartridge has been removed while instrument is still switched on Switch off and fit cartridge 29 Communications error Check connections to Base Station 30 Time date not set Set clock using PC software 31 Event log nearly full Clear log to reset 20 or less remaining When full the instrument will start overwriting the oldest data Download the log to retain oldest data 32 Gas log nearly full Clear log to reset 20 or less remaining When full the instrument will start overwriting the oldest data Download the log to retain oldest data 33 Cal log nearly full Clear log to reset 20 or less remaining When full the instrument will start overwriting the oldest data Download the log to retain oldest data 34 See manual Memory error A sensor parameter is out of the permitted range 35 Insert valid cartridge Memory fault Incorrect format 36 See manual Memory error in alternative language Instrument will revert to English 50 Switch on off to reset An electronics fault has occurred One of the sensors has detected a gas that has caused a large negative cross sensitivity 51 Calibration required Cell is producing an excessive negative reading Recalibrate 52
Download Pdf Manuals
Related Search
Related Contents
Samsung E1170 manual de utilizador SUBSOLADOR TERRUS SMC (SMC7724FMSC) Expansion Module RCA NCJ11 User's Manual Vita-Mix Blender PROFESSIONAL SERIES 300 User's Manual ANSI® Programmer`s Reference Manual Installation Manual Sony WM-EX362 User's Manual 平成22年度富谷町立成田中学校校舎増築工事 Copyright © All rights reserved.