Home

5204SE-MNET-PDPMV1Datasheet

image

Contents

1. ProSoft Ra a OA INL HM ONL TOTGEN DATASHEET Modbus TCP IP to PROFIBUS DPV1 Master SE Gateway 5204SE MNET PDPMV1 Automating integration for Schneider Electric Modicon processors and maximizing ease of use are i a the hallmark design criteria behind the new ProLinx SE line of communication gateways The first SE 7 _ it gateway the 5204SE MNET PDPMV1 Modbus TCP IP to PROFIBUS DP V1 Master gateway easily Fi turns a Modicon M340 or Quantum Programmable Automation Controllers PAC into a PROFIBUS DP V1 Master The new Application Communication Logic functions built into ProSoft Configuration Builder PCB automatically generate all the Unity Pro data types variables and logic required for the M340 or Quantum to perform PROFIBUS DP V1 cyclic and acyclic communication PCB automatically generates customized export files based on the gateway s PROFIBUS DP network configuration These files import into Unity Pro version 4 software without modification eliminating the need to write additional communications message logic Automatically generated Derived Function Block logic also provides advanced PROFIBUS DP V1 acyclic message pass through capability Acyclic messaging allows access to extended slave data and diagnostics as well as access to slave specific special functions Whenever the PROFIBUS DP network configuration changes new logic files can be automatically created exported and imported into an existing Unity
2. Error codes counters and port status available through automatically created Application Communication Logic DFBs and variables General Specifications PDPMV1 The module supports Master specifications according to IEC 61158 Cyclic I O data and acyclic message parameter data can be transferred with PROFIBUS DP V1 Class 1 or Class 2 services allowing processors to easily communicate with slave devices supporting PROFIBUS DP V0O or DP V1 protocol trt PCB Ethernet Configuration amp FDT DTM Ethernet Communication Modicon M340 PAC Ethernet Switch Modbus TCP IP Ethernet Modicon Quantum PAC PCB RS 232 Serial Diagnostic Communication B csr ProLinx 5204SE MNET PDPMV1 PROFIBUS DP an ae T DP PA third party coupler or link module PROFIBUS PA Functional Specifications Modbus TCP IP Modbus Commands 1 Read Coils Status 6 Preset Write Single Supported 2 Read Input Status Holding Register Client and Server 3 Read Holding Registers 15 Force Write Multiple Coils 4 Read Input Registers 16 Preset Write Multiple F W 5 Force Write Single Coi Holding Redisters Configurable Gateway IP Address Parameters Modbus data type starting address offsets Client and Server Floating point start address and database offset Configurable Minimum Command Delay Parameters Response Timeout Client Only Retry Count Command Error Pointer Command List Up to 100 fully c
3. only Supports Sync and Freeze commands Hardware Specifications Specification Power Supply Current Load Operating Temperature Storage Temperature Relative Humidity Dimensions LED Indicators Configuration Serial Port Ethernet Port Ethernet protocol gateways only Application Serial Port s Serial protocol gateways only Serial Port Isolation Shipped with Each Unit Description 24 VDC nominal 18 to 32 VDC allowed Positive Negative GND Terminals 2 5 mm screwdriver blade 500 mA max 32 VDC max 20 to 50 C 4 to 122 F 40 to 85 C 40 to 185 F 5 to 95 non condensing Standard 5 20 H x 2 07 W x 4 52 D inches 13 2 cm H x 5 25 cm W x 11 48cm D Extended 5 20 H x 2 73 W x 4 52 D inches 13 2 cm H x 6 934 cm W x 11 48cm D Power and Module Status Application Status Serial Port Activity LED Serial Activity and Error LED Status DB 9M RS 232 only No hardware handshaking 10Base T half duplex RJ45 Connector Link and Activity LED indicators Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s applied as specified in section 5 3 2 of IEC 60950 1991 Ethernet Broadcast Storm Resiliency less than or equal to 5000 ARP frames per second and less than or equal to 5 minutes duration RS 232 422 485 RS 232 handshaking configurable RS 422 485 DB 9 to Screw Terminal Adaptor Note The number of serial application ports depends on the module type and the combination of
4. Pro project reducing engineering demands and cutting deployment time Changes to the gateway s configuration can be password protected CO New Application Communication Designed specifically to enable a Modicon M340 or Quantum PAC using Modbus TCP IP to Logic functions for use with act as a PROFIBUS DP V1 Master ao M340 and Quantum Generates Unity Pro version 4 0 DFB logic and variable files from gateway configuration Automates the creation of application communication logic Ease of use means faster deployment less engineering effort fewer programming errors gt gt Acyclic Pass Through Capability Automatically generated DFBs enable advanced PROFIBUS DP V1 acyclic messaging with minimal engineering and programming effort Acyclic messaging allows a M340 or Quantum PAC to communicate directly with PROFIBUS DP slaves to access special slave features and to get extended slave diagnostics and process data Backed by ProSoft Technology 20 year history of delivering high quality reliable solutions designed with you in mind Free unlimited worldwide Technical Support by phone for pre sale set up or troubleshooting support helps you get going sooner and stay running longer Three Year Warranty ensures reliability and protects against equipment failures Free ProSoft Software tools tightly integrate with our hardware a simple and quick total solution to help you make our products fit your applications Conf
5. iguration ProSoft Configuration Builder PCB with new Application Communication Logic functions provides a PC based software configuration solution for managing gateway a configuration files viewing communication status and monitoring network diagnostics C 2 as well as password protected configuration downloads The 5204SE MNET PDPMV1 User Manual provides step by step instructions on how to move data from one network P L to the other rO Inx General Specifications ProLinx Gateways ProLinx Communication Gateways provide connectivity for two or more dissimilar network types The gateways encased in sturdy extruded aluminum are stand alone DIN rail mounted solutions that provide data transfer between many of today s most widely used industrial automation protocols General Specifications SE Modbus TCP IP The ProSoft Technology special SE Modicon Modbus TCP IP implementation uses the gateway s shared internal memory database for data transfer Sharing the memory database with another protocol driver allows the gateway to transfer data between Modbus TCP IP devices and devices on other networks This special version of the protocol the first of its kind has been developed to add PROFIBUS DP V1 Master capability to Modicon PACs using their native Modbus TCP IP communications capabilities and Unity Pro version 4 0 programming software Modbus TCP IP Server Slave The Modbus TCP IP MNET server driver
6. in the 5204SE MNET PDPMV1 is a special adaptation of the standard ProSoft Technology MNET driver enhanced with Application Communication Logic functions for Unity Pro version 4 This special driver accepts incoming connections on Service Port 502 for Clients using Modbus TCP IP MBAP messages and from Clients on Service Port 2000 or other Service Ports for Clients using Encapsulated Modbus messages e Supports a total Modbus TCP IP data transfer capacity of up to 4000 registers or up to 64 000 bits in any combination of data types throughout the 4000 register memory database for read requests from remote Modbus TCP IP Clients e The special version of the MNET server accepts write requests from remote Modbus TCP IP Clients only when those requests write to register memory database addresses in the range specified for PROFIBUS Output data to be sent to slave devices on the PROFIBUS DP network e Supports five independent server connections for Service Port 502 MBAP e Supports five independent server connections for Service Port 2000 Encapsulated e Modbus data types overlap in the gateway s memory database so the same data can be conveniently read or written as bit level or register level data Modbus TCP IP Client Master e Actively reads data from and writes data to Modbus TCP IP devices using MBAP or Encapsulated Modbus message formats e Offers one Client connection with up to 100 commands to talk to multiple servers Status Data
7. onfigurable Client commands Status Data Error codes reported individually for each command Command List Polling Each command can be individually enabled or disabled write only on data change Is available Functional Specifications SE PROFIBUS DP V1 Master Application Communication Logic functions in PCB automatically generate Unity Pro v4 0 DFB communication logic and variables for Modicon M340 and Quantum PAC systems from the PROFIBUS DP V1 Master configuration Easy to use drag and drop Master Busview configuration interface via ProSoft Configuration Builder software Project unique GSD file import library Automatic Bus Parameter calculation Online slave diagnostics through PCB Supports all standardized baud rates up to 12 Mbps Supports extended diagnostic data DP V1 only Auto baud detection at all valid PROFIBUS DP V1 rates CRC checksum determination of slave to processor configuration consistency LED indicators for network Communication Status Master Status Token Hold status and Database Configuration Status FDT DTM PROFIBUS DP Master transport communication DTM software included see PSW CDTM PDPM Up to 125 total slaves can be connected when using repeaters up to 32 total nodes per network segment between repeaters Up to 1536 cyclic bytes input and 1536 bytes output data Optically isolated PROFIBUS DP interface with on board DC DC converter Modbus TCP IP pass through of acyclic read and write messages DP V1
8. protocols 2500V RMS port signal isolation per UL 1577 3000V DC min isolation port to ground and port to logic Mini DIN to DB 9M serial cables 4 ft RS 232 configuration cable 2 5mm screwdriver CD docs and Configuration utility RS 422 485 DB 9 to Screw Terminal Adaptor for each serial application port serial protocols only Agency Approval amp Certification UL cUL ISA 12 12 01 Class Div 2 Groups A B C D cUL C22 2 No 213 M1987 243333 CE We 183151