Home
Kings Fund Bed User guide
Contents
1. KINGS FUND BED Nursing care bed User Instructions Thank you for choosing a Kings Fund 2101 Bed This user manual should be read carefully before you use your bed as it contains important information regarding safe operation and maintenance in order to provide long lasting and reliable service Please ensure that you understand all the instructions if you have any questions concerning the operation and maintenance of the bed please contact your supplier who will provide you with expert professional advice In line with our policy of continuous improvement we welcome any suggestions that could lead to product improvement Contents Section Title Page Introduction Parts Identification Specifications Operating the Bed Do s amp Don ts Cleaning Procedure Maintenance Accessories Warranty ee ae St ee Te 10 0 ON KRW ND 1 Introduction Your Kings Fund Bed is a traditional hospital bed for general ward use It has a manually adjustable variable height mattress platform two way tilt system gas assisted rising backrest bed extension and a full width bed stripper The bed is designed to support a maximum user weight of up to 80kg 28 stone The light oak laminate head and foot ends are fire retardant and easy to remove J ee oa e o Parts Identification Head Board Protective Buffer Mattress Platform Backrest Operating Lever Height Adjustment Pedal Base Chassis Central Locking Castor Brake
2. Pedal Tilt Handle Bed Stripper Tilt Handle Foot Board Bed Extension Handwheel Rising Backrest 3 Specification Overall Length 2210 mm Overall Width 1000 mm Maximum Mattress Platform Height somm to the top of the mattress platform Minimum Mattress Platform Height ior to the top of the mattress platform Maximum Overall Height 1590 mm 62 5 Minimum Overall Height 1220 mm 48 Castor Size 125 mm 5 Maximum User Weight 180kgs 28 stone Minimum Under Bed Clearance 155 mm 6 Mattress Extension 185 mm 7 4 Operating the Bed Height Adjustment Raising the bed Using the height adjustment pedal situated half way along the base chassis labelled raise depress the pedal with a pumping action This will raise the bed to the desired height Lowering the bed Pressing the opposite end of the height adjustment pedal labelled lower will lower the bed Mattress Platform Tilt Head Down Tilt Firmly support the bed and raise the right hand tilt handle situated at the foot end of the mattress platform While holding the handle lift the mattress frame up to a maximum of 2 in 2 increments to the desired level of tilt Releasing the handle will lock the bed in the required position Foot Down Tilt Firmly support the bed and raise both tilt handles situated at the footend of the mattress platform While holding both handles lower the footend to a maximum
3. both handwheels situated at the footend of the mattress frame and pull out the extension with both hands Re tighten the handwheels to lock the extension in place To return to standard length Unscrew both handwheels and push Handwheel the extension back into the normal position Secure in place by tightening the handwheels 5 Do s amp Don ts Do ensure you read these instructions and fully understand them before setting up or using the bed Do ensure the bed is cleaned on a regular basis Do ensure the bed Is inspected on a regular basis minimum once yearly service Do ensure the lock pin has re engaged after tilting the mattress platform Do Not exceed the beds safe working load of 8Okg 28 stone Do Not use the rising backrest feature to lift the occupant Do Not store any items under the bed Do Not allow children to play with or under the bed Do Not allow any part of the bed or mattress to come into contact with any naked flame or excessive heat sources 6 Cleaning Procedure Biocote Your bed comes with an antibacterial additive Incorporated into the powder coated metalwork Biocote inhibits the growth of bacteria on the surface of the bed frame It is effective against a wide range of both gram positive and negative bacteria as well as fungi Examples of bacteria that Biocote is resistant to include Bacillus Subtilis Staphylococcus Aureus MRSA Escerichia Coli 0157 Streptococcus Faecalis S
4. almonella Enteritides Listeria Monocytogenes Biocote is an aid to keeping your bed infection free but it does not substitute the need for the bed to be cleaned at regular intervals Cleaning All surfaces to be wiped down with a soft cloth moistened with a mild detergent or the hospital s recommended cleaning solution and diluted in hot water Extra care should be taken around areas where excess dirt or dust may gather Rinse down with clean water and dry off with a paper towel If any infectious material s have been in contact with the bed or it has been used by a patient with a known infection the above procedure should be followed by an additional clean with NaDCC Presept Actichlor at 10 000 PPM of Chlorine or instructions as prescribed by manufacturer Rinse and dry again Always ensure that cleaned parts are allowed to dry before putting the mattress back In place 7 Maintenance The Kings Fund Bed Is designed to require very little maintenance however if there are any signs of damage or the bed is not performing as it should then please contact your supplier for further assistance Any maintenance should only be carried out by suitably qualified personnel Periodically check to ensure that all fixings including nuts and bolts are tight and that none are missing Check that all cables are in good condition and not excessively kinked Sidhil recommends these checks be carried out annually If the bed does not op
5. erate e Check that the bed is free of any obstacles e Check that the maximum load has not been exceeded e Check that the bed has not reached it s minimum or maximum height e Check that the pedal used to raise and lower the bed is free of any obsatcles 8 Accessories Code Description 2100 T PEDAL Dual sided pedal 292 6 LP Lifting pole strap and handle 21Q0 DP Transfusion pole with clamp For the full range of side rails side rail pads and mattresses please speak to the Sidhil Customer Service Team Contact details can be found on the back of this booklet 9 Warranty Sidhil Ltd guarantees this product is free from defects in material and workmanship under normal use for 3 years year full parts and labour 2 further years parts only from the date of purchase from Sidhil Ltd and its subsidiary companies or its authorised dealers All implied warranties including but not limited to those implied warranties of fitness and merchantability are limited in the total duration of three years from date of purchase Proof of purchase must be presented with any claim Except as provided herein Sidhil Ltd product warranty does not cover damage caused by misuse or abuse accident the attachment of any unauthorised accessory alteration to the product or any other conditions whatsoever that are beyond the control of Sidhil Ltd Sidhil Ltd and its subsidiary companies shall have no liability or responsibility to customer or any other p
6. erson or entity with respect to any liability loss or damage caused directly or indirectly by use or performance of the product or arising out of any breach of this warranty including but not limited to any damages resulting from inconvenience loss of time property revenue or profit or any indirect special incidental or consequential damages even if Sidhil Ltd or their subsidiary companies or authorised dealers has been advised of the possibility of such damages In the event of a product defect during the warranty period you should contact Sidhil Ltd or their authorised dealer who will at its option unless otherwise provided by law a correct the defect by product repair without charge for parts and labour b replace the product with one of the same or similar design or c refund the purchase price All replaced parts and products on which refund is made become the property of Sidhil Ltd New or reconditioned parts and products may be used in the performance of warranty service Repaired or replaced parts and products are warranted for the remainder of the original warranty period You will be charged for repair or replacement of the product made after the expiration of the warranty period This warranty does not cover a damage or failure by or attributes to acts of God abuse accident misuse improper or abnormal usage failure to follow instructions improper installation or maintenance alterations lightning or other incidence of excess v
7. of 6 in 2 increments Releasing the handle will lock the bed in the required position To Level the Bea Firmly support the bed and raise the right hand tilt handle situated at the footend of the mattress platform while holding the handle raise or lower the footend until it is level When operating the tilt function always ensure the lock pin has engaged after the handle is released Braking and Steering There are two linked brake pedals at the foot end of the bed which control all the castors simultaneously When the pedal is in the steer position It locks one castor on the bed so that it cannot swivel This allows the bed to be steered when being pushed from the head end of the bed When the pedal is in the tree position no castors are locked allowing all to swivel freely eWhen the pedal is in the brake position three castors are locked and the bed then cannot move Raising and Lowering the Backrest Raising Lift the backrest operating lever on the mattress platform While holding the lever lift the backrest to the desired angle Note The heavier the patient the harder it will be to lift the backrest Lowering Lift the backrest operating lever and push the backrest down to the desired position Note The backrest may Backrest operating lever drop under it s own weight when the lever is lifted depending on the weight of the patient Bed Extension To extend Unscrew
8. oltage or current b any repairs other than those provided by a Sidhil Ltd authorised technician c consumables such as fuses d cosmetic damage e transportation shipping or insurance costs or f costs of product removal installation setup service adjustment or re installation This limited three year warranty gives you specific legal rights and you may also have other rights Sidhil Ltd cannot be held responsible for any injury or incident which relates to the use of the Sidhil 2101Kings Fund bed in conjunction with accessories manufactured by companies other than Sidhil Ltd All products carry the CE mark in accordance with EC Directive on Medical Devices 93 42 EEC Sidhil has a policy of continual product improvement and reserves the right to amend specifications covered in this brochure No part of this brochure may be reproduced without the written approval of Sidhil Ltd aD E Tel 01422 233000 Fax 01422 233010 Email sales sidhil com www sidhil com Sidhil Business Park Holmfield Halifax HX2 9TN A member of the Siddall amp Hilton Ltd Group of Companies NATIONAL ACCREDITATION 93 42 EEC Certificate No FM 14550 INSTRUC 2101 REV3