Home

3Q Automation User Manual

image

Contents

1. CHRISITE 39 STATUS INDICATOR STATUS PCB STATUS PCB STATUS PCB P N 195645 001 P N 195645 001 P N 195645 001 a 1 2 5 4 38 MARS 3 12 5 3 251262728 25262728 2526 27128 AUTOMATION A AUTOMATION B AUTOMATION C RISTIE 3Q STATUS INTERFACE P C B WIRING TO AUTOMATION MAIN TERMINAL BOARD AUD STAT MODULES 195655 001 SURFACE OR JUNCTION BOX BELDEN 8632 32 WIRES ALTERNATE BELDEN 9444 4 WIRES 3Q AUTOMATIONS Phase Chec Iwo Projector Interlock 12 vac 2 Projector 0 Volts A C between automations 1 j Projector 2 5 B 12 VAC 25 Om 3Q Without P35GP AutoTurret Masking AutoFocus KELMAR 7927 K2 598931
2. QO O OH mH ea nl TB1 TART LATCH of 3 2 Bheet Thursday August 04 2005 THESE DRAWINGS AND SPECIFICATIONS ARE THE EXPRESS PROPERTY OF CHRISTIE DIGITAL SYSTEMS AND SHALL NOT BE REPRODUCED OR COPIED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS WITHOUT EXPRESS WRITTEN PERMISSION OF CHRISTIE DIGITAL SYSTEMS 115VAC LINE 115VAC NEUTRAL GROUND MOTOR MOTOR LAMP LAMP DOUSER CO DOUSER OPE DOUSER CLOSE CURTAIN CO CURTAIN OPE CURTAIN CLOSE DRY CIRCUIT CO DRY CIRCUIT N C DRY CIRCUIT N O W103 123 TB2 W117 122 12VAC 12VAC GND MOTOR LAMP SPARE POWER Date MOTOR POWER ENABLE DOUSER OPEN ENABLE DOUSER CLOSE ENABLE POWER RELAYS Document Number 503380 Thursday August 04 2005 Sheet 3 of Rev 2
3. 68 O N vr uondo gg uxo yy 0 Manual Option 2 Wiring Curtain Control um m FT LOS 5 C pm m 9 m idu T P Lan s g Sl O Py O O O XJ OF N N Ww S d Cy C X me X E TB5 Jumper Jumper Jumper To Curtain motor Low voltage only NOTE Automation will automatically open close curtain with c o dowser Option Wiring Independent Masking Control 2 Sp ue em FF fees Sa lt d x a oo m S m S m UD ap ep ei 5 O 4 NM AS X 432 WW SX Eo O b 185 use a Jumpers NOTE Automation will automatically change masking with turret
4. 587700 077 546102 011 195838 001 13 Appendix A Wiring Diagrams Appendix A contains wiring diagrams associated with options available with the 3Q automation Cue Detector Wiring for 598931 690 3Q Failsafe Option One Wiring Two Projector Interlock Option Two Wiring Manual Curtain Control Option Two Wiring Manual Masking Control 3Q Status Panel Wiring 3Q Status Wiring Riser Diagram Phase Check Two Projector Interlock 3Q Wiring w o P35GPS Projector Y V VV V V V V V 3Q Automation Schematic CD D am D 2 fa Cu Wiring and Cue Placement Show Start INBOARD CUE Feature CENTER CUE Show End OUTBOARD CUE jussa ne GROUND BROWN SENSORS RELAYS WHITE a GRAY INBOARD CUE U rE a A BLUE FEATURE CUF REN a i YELLOW OUTBOARD CUE gt ORANGE 1 TL RP lt n ANZ FAIL SAFE PROXIMITY CUE FAILSAFE P N 598931 690 iring 97 13218 sJowey cv 1 1 gt Fesiteg TF ON 41 uondo 0 tio gy tondo a Q Eu Q QO 4 gt 69 ON VI uendo Option 1 W gg mog y uondo Projector 1 Projector 2 97 326935 slourn q SF 1 syesiTred O 1 ON gr uondo oy won gy uondo
5. DRY CIRCUIT N O Piezo Alarm ON CHASSIS START PB3 MOTOR LAMP FORMAT S1 S2 7 CLOSE ON OFF ON OFF ON OFF ON ON OFF ON START START FEATURE FEATURE FORMAT AUDIO FORMAT AUDIO OPTIONI OPTION2 56 57 S8 S9 10 11 FLAT BN st LAT SR ON A un ut un J8 ON OFF O ON OFF ON J 9 j O D 11 QTY CODE PART OR NOMENCLATURE MATERIAL ITEM REQD IDENT IDENTIFYING NO OR SPECIFICATION SPECIFICATION NO PARTS LIST UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES TOLERANCES ARE FRACTIONS DECIMALS ANGLES CONTRACT NO MG BERGMAN 07 07 05 CHIKISTIE 3Q AUTOMATION WIRING DIAGRAM Doe rm C 8 5030 APPLICATION ISSUED QN r LO cO TB2 THESE DRAWINGS AND SPECIFICATIONS ARE THE EXPRESS PROPERTY OF CHRISTIE DIGITAL SYSTEMS AND SHALL NOT BE REPRODUCED OR COPIED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS WITHOUT EXPRESS WRITTEN PERMISSION OF CHRISTIE DIGITAL SYSTEMS PCB ASSY 81 50380 T2 Date INO WHZZzng8 NSJVS IIV4 MOOTAALNI IVWHOS3 4 IYWAO4J LAVIS OO MS LVWuOd WuvIV Il InV3 OIVOIGNI dOLS OIVOIGNI NAY WACT 11082 HUIS HWS 03 an no 0 MOHS NO and LAWLS MOHS ONAS NON OIGQV AanLYyad lVWuOd OIANY LAVIS WOO MS OIANY NMOG WHWNIG GIN 2111110 an 11110 WOO LONJA X4
6. 676 Optional ea ma AutoFocus PCB amp o O Blo lt P1 gt Neutral TB5 2 Turret Masking Option Control P3 E Jumper 6 Gs COCA e QE 2 EBS lt N CG a A 23 5 lt 2 E S 2 a TE NOTE Use 120V latching relay for AutoFocus THESE DRAWINGS AND SPECIFICATIONS ARE THE EXPRESS PROPERTY OF CHRISTIE DIGITAL SYSTEMS AND SHALL NOT BE REPRODUCED OR COPIED OR USED AS THE BASIS FOR THE MANUFACTURE OR SALE OF APPARATUS WITHOUT EXPRESS WRITTEN PERMISSION OF CHRISTIE DIGITAL SYSTEMS 115VAC LI 115VAC NEUTRA GROU MOT MOT DOUSER C DOUSER OP DOUSER CLO DIMMER SW C DIMMER DIMMER M DIMMER DO AUDIO SW C STER DIGIT NON SY SHOW START C FEATURE C SHOW END C FAIL SA GROU 12V RUN INDICAT STOP INDICAT FAULT ALA DRY CURCUIT C DRY CURCUIT N DRY CURCUIT N LENS C LENS FL LENS SCO CURTAIN C CURTAIN OP CURTAIN CLO OPTIO AC OPTION 1A N OPTIO BC OPTION 1B N OPTION 2 CO OPTION 2 OPTION 2 FAIL SAFE BU START BU 0 0 0 E 0 UP ID 0 EO SR AL UE UE UE FE D AC OR OR RI 0 0 AT PE 0 E SE 0 0 0 0 A B SS SS MASKING COM MASKING FLAT MASKING SCOPE DIMMER C DIMMER DIMMER M DIMMER DOW AUDIO SW CO START AUDIO FORMAT FEATURE AUD 0 UP ID 10 ON SYNC SHOW START CUE
7. Cue Active only when Start Relay is latched Brings lights to MID audio to Mono Stereo douser open curtain open Manual Feature Cue Active only when Start Relay is latched Brings lights to LOW audio to Stereo SR feature picture format to Flat or Scope Manual Show End Cue And Alarm Cancel Brings lights UP audio to non sync douser close curtain close start picture format to Flat or Scope ON OFF Switch May be used for interlock activation Pre wired to TB5 38 41 see wiring diagram Momentary Switch May be used for manual curtain control Pre wired to TB5 42 44 see wiring diagram Sounds alarm if a film break occurs Automation main fuse 2 Amp 3AGC COMPONENT FUNCTION P C B Assembly Start Relay K1 Stop Relay K2 Alarm Relay K3 Show End Relay K4 Feature Relay K5 Show Start Relay K6 Power Relay K7 Open Relay K8 Close Relay K9 Transformer T1 All low voltage control circuitry Latches through Stop Relay Holds Power Relay latched engaging motor and lamp Disengages Start Relay Relay is latched when fail safes are down Sounds alarm if Stop Relay is latched due to fail safe Alarm sounds if show is between the Show Start and Show End Cues Actuates Show End Cue functions Disengages Alarm Relay Actuates all Feature Cue functions Actuates all Show Start Cue functions Latches Alarm Relay Activated by Start Relay engages motor and lamp 3PDT 12V
8. FEATURE CUE SHOW END CUE CUE CO FAIL SAFE REMOTE START GROUND 12VAC RUN INDICATOR STOP INDICATOR FAULT ALA RM FORMAT SW COM START FORMAT FEATURE FORMAT INTERLOCK FAIL SA BUZZER O FE UT 2 s Rer TB5 2 Fw J w4 mw WA WEN Ws A WE 6 w7 74 W74 A WIN s Wa WEA way o Wars WEA WON wir WIN LLB Wm PF WN W12 79 W79N m S WIN 19 9292 14 SEQ iW I PWN wis ig WIB E FUR Ma ewn 21 01 wer f WAN 21 22 wen WN W23 83 W83 413 aa we way L wes as Was 28 w28 86 185 ws 29 A 30 mar 7 was wer 35 Sf WY aW UN 341 w57 85 ae 88 w 2 W88 ann Owe 43 Pf WN wd4 41 W44 dm 46 W46 88 wees 47 48 49 50 TB 3 OO Ki Ne ON PCB ASSY FRONT PANEL AND HARNESS REVISIONS DESCRIPTION DATE APPROVED REV PER ECO 23751 02 27 96 GJS A REV PER ECO 23766 04 01 96 GJS 2 REV PER ECO 05 2499 08 04 05 GVB F1 2A TES 115VAC LINE 115VAC NEUTRAL GROUND MOTOR MOTOR LAMP LAMP DOUSER COM DOUSER OPEN DOUSER CLOSE LS1 CURTAIN COM CURTAIN OPEN CURTAIN CLOSE 0 DRY CIRCUIT COM DRY CIRCUIT N C 86 6
9. A CHRISTIE Operating Instructions For AUTOMATIO TD 685 CHRISTIE INC mden Dr Cypress Ca 90630 714 236 8610 Fax 714 229 3185 The CHRISTIE 3Q is a console mounted cue driven automation designed specifically for the CHRISTIE P35GPS Projector SLC console combination This cost efficient design provides control of most booth and auditorium functions including the projector motor Xenon lamp changeover douser house light dimmer up mid down audio switching Stereo SR Digital Non sync stage curtains slide projector remote status indication run stop fault ready built in two projector interlock full remote capability lens turret masking and Xenon Auto Focus control for properly equipped projectors and consoles The automation provides manual control of all functions and cues as well as two user assignable option switches pre wired to the main terminal board The automation utilizes a reliable cue detector instead of a cam timer to initiate the various automated functions A cue expander may be utilized to provide up to four additional custom functions i e special dimmer functions mid show stop additional sound formats etc The compact printed circuit board design provides reliable trouble free operation with the familiarity and simplicity of electro mechanical relays SUMMARY OF FEATURES Designed specifically for PSSGPS SLC combination Separate trailer and feature pre selects for picture and
10. AC coil with 10A rated contacts Opens douser and stage curtains 3PDT 12VAC coil with 10A rated contacts Closes douser and stage curtains 3PDT 12VAC coil with 10A rated contacts 12VAC 2 Amp transformer Provides 12V power for automation Check Note Make sure both Automations are on the same phase TB5 25 should read 0 VAC between the two Automations see wiring diagram Connect Remote Start 46 to Option 1A Common 38 in each automation Connect Fail safe Interlock 45 to Option 1B Common 40 in each automation Connect Option 1A N O 39 and Option 1B N O 41 from projector 1 to their corresponding terminals on projector 2 Switching on the Option 1 switches in both automations will activate interlock Tie up both sets of fail safes to ready position Press start on either automation Both projectors motors and lamps will start As the cues pass through each automation functions will be performed independently as usual Once the Show Start Cue has gone through both automations fail safe protection for the interlock will be active Dropping of the fail safes on either projector will stop both projectors raise the house lights and sound the alarms Once the Show End Cue has gone through one of the automations interlock fail safe will be discontinued and the projectors will shut off independently as the film runs out TB 1 Automation PCB Reference Only 1 Dimmer Sw
11. audio formats Reliable relay and PCB based design Built in two projector interlock Full manual controls for all functions including cues All low voltage controls on PCB LED illuminated run stop and cue buttons for long service life Panel mounted alarm buzzer Two pre wired user assignable option switches gt Full remote control and status capabilities Start Button Motor On Lamp On Douser Close Slide Projector Off Lens Masking AutoFocus to Start Format selectable Start Cue at beginning of trailers Dimmer Mid or Down Curtain Open Douser Open Start Audio to Stereo or SR selectable Status Indicator to Run Feature Cue at beginning of feature Dimmer Down Feature Audio to Stereo SR or Digital selectable Lens Masking AutoFocus to Feature Format selectable Show End Cue at end of feature credits Curtain Close Douser Close Dimmer Up Audio to Non Sync Lens Masking Auto Focus to Start Format selectable Film Run Out Motor Off Lamp Off Slide Projector On Status Indicator to Stop 4 Fault Film Break Motor Off Lamp Off Dimmer Up Slide Projector On Status Indicator to Fault Alarm Sounds 4 Cancel Alarm Shuts off Alarm Douser Close Audio to Non Sync The CHRISTIE 3Q automation utilizes three different cues for normal show operation Show Start inboard cue gt placed two feet prior to the start of the trail
12. ers Feature center cue gt placed two feet prior to the start of the feature or policy trailer 4 Show End outboard cue gt placed two feet prior to the end of the credits Note The automation may be used with any cue sensor which provides at least three cues with consistent duration contact closure when a cue is detected SWITCH Start PB 1 Stop PB 2 Motor S1 Lamp S2 Douser S3 Dimmer S4 Format S5 Start Audio S6 Start Format 57 Feature Audio S8 FUNCTION Latches Start Relay engaging motor and lamp Turret masking to start format closes douser audio to non sync Slide projector OFF Will not start if fail safes are down L E D illuminated green when active Disengages Start Relay motor and lamp OFF Slide projector ON L E D illuminated red when active or fail safes are down Manual motor control Manual lamp control Manual opening and closing of changeover douser Manual raising or lowering of house lights Manual control of lens turret aperture masking Auto Focus Selects trailer audio format to Stereo or SR Selects trailer picture format to Flat or Scope Selects feature audio format to Stereo SR or Digital SWITCH FUNCTION Feature Format S9 Start Cue PB 3 Feature Cue PB 4 Show End Cue PB 5 Option 1 S10 Option 2 S11 Buzzer LS1 Fuse F1 Selects feature picture format to Flat or Scope Manual Show Start
13. itching Common W78 2 Dimmer Up W79 3 Dimmer Mid W13 4 Dimmer Down W80 5 Audio Switching Common W15 6 Start Audio Format W62 7 Feature Audio Format W63 8 Non Sync W19 9 Show Start Cue W64 10 Feature Cue W81 11 Show End Cue W82 12 Cue Common W65 13 Fail Safe W83 14 Remote Start W88 15 Ground Automation Switching Common W84 16 12VAC W85 17 Run Indicator W20 18 Stop Indicator W27 19 Fault Indicator Alarm W86 20 Format Switching Common W87 21 Start Format W89 22 Feature Format W90 23 Interlock Fail Safe Input Output W45 24 Buzzer output W91 TB 2 Automation PCB 194898 001 1 12 VAC W117 W122 2 Ground W118 W123 3 Power Relay W119 4 Open Relay W120 5 Close Relay W121 6 Alarm Active 12VAC when active 10 TB 3 Automation Chassis 195631 001 1 Line 115VAC W61 2 Neutral W2 3 Ground W3 4 Motor W71 5 Motor W72 6 Lamp W73 Z Lamp W74 8 Douser Common W75 9 Douser Open W76 10 Douser Close W77 11 Curtain Common W35 12 Curtain Open W36 13 Curtain Close W37 14 Dry Circuit Common W29 15 Dry Circuit N C W30 16 Dry Circuit N O W31 TB 5 Main Console Terminal Board Field Terminations 1 Line 115VAC Feed to Automation W1 2 Neutral to Automation W2 3 Ground W3 4 Motor W4 W71 5 Motor W5 W72 6 Xenon W6 W73 7 Xenon W7 W74 8 Douser Common W8 W75 9 Douser Open W9 W76 10 Do
14. user Close W10 W77 11 Dimmer Switching Common W11 W78 12 Dimmer Up W12 W79 13 Dimmer Mid W13 14 Dimmer Down W14 W80 15 Audio Switching Common W15 16 Stereo W16 17 SR W17 18 Digital W18 19 Non Sync W19 20 Show Start Cue N O CIRCUIT W20 W64 21 Feature Cue N O CIRCUIT W21 W81 22 Show End Cue N O CIRCUIT W22 W82 Fail Safe Fire Alarm Shutdown W23 W83 Ground Switching Common W24 W84 12VAC W25W85 Run Indicator W26 Stop Indicator W27 Fault Indicator Alarm W28 W86 Dry Circuit Common W29 Dry Circuit N C 15A CONTACT W30 Dry Circuit N O W31 Lens Common W32 W87 Lens Flat W33 Lens Scope W34 Curtain Common W35 Curtain Open W36 Curtain Close W37 Option 1A Common W38 Option 1A N O W39 Option 1B Common W40 Option 1B N O W41 Option 2 Common W42 Option 2 A W43 Option 2 B W44 Fail Safe Buss Input Output W45 Start Buss N O CIRCUIT W46 W88 Masking Common W47 Masking Flat W48 Masking Scope W49 Note COMPONENT PART NUMBER Push Buttons Start Green Stop Red Cues White Switches 51 52 S10 DPST S3 S4 S5 511 SPDT Mom S6 S7 S8 SPDT S9 SPDT Center off Relays K1 K6 4PDT Small K7 K9 3PDT Large Other Buzzer Transformer Fuse Cable Automation Cable Assembly 578000 079 578000 078 578000 077 578722 024 578712 018 578722 017 578712 003 599000 122 571312 001 546900 035

Download Pdf Manuals

image

Related Search

Related Contents

Manuale D`uso e Manutenzione  Bedienungsanleitung MI 2088 Erdungs - Isolations - Prüfgerät  Canon VB-S900F Specifications  Polycom 7000E User's Manual  Production Testing of Thermistors Using the Model 2400  DeLonghi PAC 400 Air Conditioner User Manual  Vantec CBL-MDHDMI    BENDIX TCH-003-011 User's Manual  télécharger le document  