The 2-tone RF Sounder, 2-in-1 wireless receiver, is
Contents
1. default value 5 0 5 C 0 Reporting disabled e 1 127 0 1 C 12 7 C step is 0 1 C Technical Specifications Power supply 110 230 VAC 10 50 60Hz 24 30VDC Rated load current of AC 2 X 4A 230VAC 2 X 4A 30VDC 2 X 920W 230VAC output resistive load Rated load current of DC output resistive load Output circuit power of AC output resistive load Output circuit power of DC 2 X 96W 24VDC output resistive load accuracy P gt 200W 3 Digital temperature sensor ordered separately Distance up to 30 m indoors depending on building materials Dimensions WxHxD 41 8x36 8x16 9mm package 79x52x22 Weight Brutto with package 28g 34g range sensor must be Electricity consumption For installation in boxes 60mm or 2M Switching In case of load other than resistive pay attention to the value of cos and if necessary apply load lower than the rated load Max current for cos g 0 4 is 2A at 250VAC 3A at 24VDC Z Wave Device Class BASIC_TYPE_ROUTING_SLAVE GENERIC_TYPE_SWITCH_MULTILEVEL SPECIFIC_TYPE_CLASS_B_MOTOR_CONTROL Z Wave Supported Command Classes COMMAND_CLASS_SWITCH_MULTILEVEL_V3 COMMAND_CLASS_ BASIC COMMAND_CLASS_SWITCH_MULTILEVEL_V3 COMMAND_CLASS_SWITCH_ALL COMMAND_CLASS_SWITCH_BINARY COMMAND_CLASS_METER_V3 COMMAND_CLASS_SENSOR_MULTILEVEL_V3 COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_MANUFA
2. Automatic calibration Automatic calibration is a process during which the Flush shutter learns the position of the limit switches Shutter positioning calibration par 71 set to 1 There are two procedures of calibration Calibration through main controller Ul 1 Include the module into the Z wave network according to module include instructions 2 Set the parameter 78 Forced Flush shutter calibration value to 1 3 Flush shutter performs the calibration process completing full cycle up down and up again 4 Set the parameter 78 Forced Flush shutter calibration value to 0 Calibration through the inputs I1 and I2 1 Include the module into the wireless network according to module inclusion instructions 2 Quick press the switch push button connected to l1 input and wait until the shutter reach upper limit switch 3 Quick press the switch push button connected to 12 input and wait until the shutter reach lower limit switch 4 Quick press the switch push button connected to l1 input and wait until the shutter reach upper limit switch Slates tilting position calibration par 71 set to 1 When enabling venetian blind mode position calibration for slats titling must be done After that blind position and angle of slates can be set By default full turn for slates is set to 1 5s This value can be changed according to slates types and time by value in parameter 72 1 Include and make module calibration according
3. CTURER_SPECIFIC COMMAND_CLASS_VERSION COMMAND_CLASS_MARK COMMAND_CLASS_BASIC Endpoint1 COMMAND_CLASS_SWITCH_MULTILEVEL_V3 COMMAND_CLASS_ BASIC COMMAND_CLASS_SWITCH_MULTILEVEL_V3 COMMAND_CLASS_SWITCH_ALL COMMAND_CLASS_SWITCH_BINARY COMMAND_CLASS_METER_V3 COMMAND_CLASS_SENSOR_MULTILEVEL_V3 COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_VERSION COMMAND_CLASS_MARK COMMAND_CLASS_BASIC This product can be included and operated in any Z Wave network with other Z Wave certified devices from any other manufacturers All constantly powered nodes in the same network will act as repeaters regardless of the vendor in order to increase reliability of the network Important disclaimer Z wave wireless communication is inherently not always 100 reliable and as such this product should not be used in situations in which life and or valuables are solely dependent on its function Warning Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new once the retailer is legally obligated to take back your old ap
4. Qubino lowa PLUS The INNOVATIVE and SMALLEST Flush shutter ORDERING CODE Z WAVE FREQUENCY ZMNHCD1 868 4 MHz ZMNHCD2 921 4 MHz ZMNHCD3 908 4 MHz ZMNHCD4 869 0 MHz ZMNHCD5 916 0 MHz This Z Wave module is used to control the motor of blinds rollers shades garage doors gates venetian blinds etc The module can be controlled either through a Z Wave network or through the wall switch Precise positioning is supported for motors equipped with mechanical or electronic end switches The module is designed to be mounted inside a flush mounting box hidden behind a traditional wall switch Module measures power consumption of motor and support connection of digital temperature sensor lt is designed to act as repeater in order to improve range and stability of Z wave network Supported switches Module supports mono stable switches push button and bi stable switches Installation Before the installation disconnect power supply Connect the module according to electrical diagram Locate the antenna far from metal elements as far as possible Do not shorten the antenna Danger of electrocution Module installation requires a great degree of skill and may be performed only by a qualified and licensed electrician Even when the module is turned off voltage may be present on its terminals Any works on configuration changes related to connection mode or load must be always performed
5. by disconnected power supply disable the fuse Note Do not connect the module to loads exceeding recommended values Connect the module only in accordance to the below diagrams Improper connections may be dangerous Package contents e Flush shutter Electrical diagram 230VAC Notes for the diagram Neutral lead L Live lead Q1 Output for motor UP open Q2 Output for motor DOWN close 12 Input for switch push button DOWN close l1 Input for switch push button UP open TS Terminal for digital temperature sensor only for Flush shutter module compatible digital temperature sensor which must be ordered separately S Service button used to add or remove module from the Z Wave network Durability of the device depends on applied load For resistive load light bulbs etc and 4A current consumption of each individual electrical device the durability exceeds 70 000 switches of each individual electrical device Module Inclusion Adding to Z wave network Connect module to power supply with temperature sensor connected if purchased bring module within maximum 1 meter 3 feet of the main controller enable add remove mode on main controller e auto inclusion 30 minutes after connected to power supply or press service button S for more than 2 second or press push button I1 three times within 3s 3 times change switch state within 3 seconds NOTE When connecting temperat
6. e ALL OFF active 2 ALL ON is not active ALL OFF is not active Flush shutter responds to commands ALL ON ALL OFF that may be sent by the main controller or by other controllers belonging to the system Parameter no 40 Power reporting in Watts on power change for Q1 or Q2 Set value means percentage set value from 0 100 0 100 Available configuration parameters data type is 1 Byte DEC default value 1 2 0 reporting disabled e 1 100 1 100 Reporting enabled Power report is send push only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts step is 1 NOTE if power changed is less than 1W the report is not send pushed independent of percentage set Parameter no 42 Power reporting in Watts by time interval for Q1 or Q2 Set value means time interval 0 32767 in seconds when power report is send Available configuration parameters data type is 2 Byte DEC default value 300 300s 0 Reporting Disabled 1 32767 1 second 32767 seconds Reporting enabled power report is send with time interval set by entered value Parameter no 71 Operating modes This parameter defines selection between two available operating modes Available configuration parameters data type is 1 Byte DEC default value 0 0 Shutter mode 1 Venetian mode up down and slate rotatio
7. er no 86 Power consumption at limit switch delay time This parameter defines the max time at limit switch when power consumption is below power threshold If the power consumption during this time is below power threshold par 76 the active output will switch off means that limit switch is reached Available configuration parameters data type is 1 Byte DEC default value 8 800ms 3 50 0 3seconds 5seconds 100ms resolution Parameter no 90 Relay delay time This parameter defines the time delay between output relay switching time between switching up down and vice versa Available configuration parameters data type is 1 Byte DEC default value 5 500ms 1 30 0 1seconds 3seconds 100ms resolution Parameter no 110 Temperature sensor offset settings Set value is added or subtracted to actual measured value by sensor Available configuration parameters data type is 2 Byte DEC default value 32536 o 32536 offset is 0 0C From 1 to 100 value from 0 1 C to 10 0 C is added to actual measured temperature e From 1001 to 1100 value from 0 1 C to 10 0 C is subtracted to actual measured temperature Parameter no 120 Digital temperature sensor reporting If digital temperature sensor is connected module reports measured temperature on temperature change defined by this parameter Available configuration parameters data type is 1 Byte DEC
8. hing a limit switch will not be detected Parameter no 78 Forced Shutter calibration By modifying the parameters setting from 0 to 1 a Shutter enters the calibration mode Available configuration parameters data type is 1 Byte DEC default value 0 1 Start calibration process after shutter performs the calibration process completing full cycle up down and up set the parameter 78 Forced Shutter calibration value back to 0 Parameter no 80 Reporting to controller This parameter defines if reporting regarding power level multilevel etc is reported to controller or not Available configuration parameters data type is 1 Byte DEC default value 1 0 reporting to controller is disabled 1 reporting to controller is enabled NOTE Disabling reporting is recommended in case Z wave modules communicate in association groups without using controller Parameter no 85 Power consumption max delay time This parameter defines the max time before motor power consumption is read after one of the relays is switched ON If there is no power consumption during this max time motor not connected damaged or requires higher time to start motor in end position the relay will switch OFF Time is defined by entering it manually Available configuration parameters data type is 1 Byte DEC 2 default value 0 time is set automatically 3 50 0 3seconds 5seconds 100ms resolution Paramet
9. is moving each click of any push button will stop the movement Keeping pressed push button for time gt full turn slates time par 72 connected to 11 up initiates full slates turn and up movement until the push button is released Keeping pressed push button for time gt full turn slates time par 72 connected to I2 down initiates shutter down movement until the push button is released Slates on end position 180 degree Clicking push button for time lt full turn slates time par 72 connected to l1 up initiates shutter up movement Clicking push button for time lt full turn slates time par 72 connected to l2 down initiates slates turning towards start 0 degree position until the push button is released If the shutter is moving each click of any push button will stop the movement Keeping pressed push button for time gt full turn slates time par 72 connected to l1 up initiates shutter up movement until the push button is released Keeping pressed push button for time gt full turn slates time par 72 connected to 2 down initiates full slates turn and down movement until the push button is released Configuration parameters Parameter no 10 Activate deactivate functions ALL ON ALL OFF Available config parameters data type is 2 Byte DEC o default value 255 255 ALL ON active ALL OFF active e 0 ALL ON is not active ALL OFF is not active e 1 ALL ON is not activ
10. mit switches 1 32767 0 1seconds 3276 7 seconds After that time motor is stopped relay goes to off state NOTE Important is that the reference position to manually set moving time is always shutter lower position Set parameter 74 to 0 and move the shutter using up down push buttons or main controller Ul to desired lower position On this shutter position set parameter 74 to time for complete opening or complete closing At this point shutter can be moved up open for set time but can t be moved down because this position is already set as lower shutter position To change shutter lower position below already set manual recalibration parameter 74 must be set to 0 and repeat the procedure described above In case shutter has limit switches but anyhow you would like to limit opening closing position by time you can still do it opening closing real time limited by limit switches shutter In case you put time that is longer that will stop at limit switch but the module relay will switch off after define time not by shutter limit switch Take in consideration that in this condition the positioning with slider through UI will not show correct shutter position Parameter no 76 Motor operation detection Power threshold to be interpreted when motor reach the limit switch Available configuration parameters data type is 1 Byte DEC default value 10 10W 0 127 1 127 W The value 0 means reac
11. n NOTE When setting parameter module needs to be reconfigured Please check detailed description in this manual Parameter no 72 Slats tilting full turn time This parameter defines the time necessary for slats to make full turn 180 degrees Available configuration parameters data type is 2 Byte DEC default value 150 1 5 seconds 0 Tilting time disabled 1 32767 0 01seconds 327 67 seconds NOTE If time set is too high this will result that after full turn shutter will start move up or down for time remaining Parameter no 73 Slats position This parameter defines slats position after up down movement through Ul or push buttons Available configuration parameters data type is 1 Byte DEC default value 2 O Slats return to previously set position only in case of UI control 1 Slats return to previously set position in case of UI control push buttons operation or when the limit switch is reached 2 Slats return to previously set position in case of UI control push button operation when the limit switch is reached or after receiving a STOP frame Switch Multilevel Stop Level Change from UI Parameter no 74 Motor moving up down time This parameter defines shutter motor moving time of complete opening or complete closing Available configuration parameters data type is 2 Byte DEC default value 0 0 moving time disabled working with li
12. pliance for disposal at least for free of charge This user manual is subject to change and improvement without notice NOTE User manual is valid for module with SW version S1 SW version is part of P N Example P N ZMNHCD x H1S1P1 Qubino Goap d o o Nova Gorica Ulica Klementa Juga 007 5250 Solkan Slovenia E mail info qubino com Tel 386 5 335 95 00 Web www qubino com Date 14 5 2015 Document Qubino_ Flush shutter PLUS user manual_V1 0_eng x CE
13. to section Shutter positioning calibration 2 Set parameter 71 to 1 Venetian blinds 3 Reconfigure node using gateway 4 After module reconfiguration beside main shutter widget another widget for slates control will appear on Ul 5 By default full turn movement is set to 1 5s If this time is too long after slates full cycle shutter starts moving up or down decrease this time defined with parameter 72 Manual operation for shutter par 71 set to 0 Module allows connecting of push buttons mono stable or switches bi stable to 11 and 12 terminals Clicking push button lt 2s connected to 11 up initiates up movement Clicking push button lt 2s connected to I2 down initiates down movement If the shutter is moving each click of any push button will stop the movement Keeping pressed push button gt 2s connected to 11 up initiates up movement until push button is released Keeping pressed push button gt 2s connected to 12 down initiates down movement until push button is released Manual operation for venetian blinds par 71 set to 1 Slates on start position 0 degree Clicking push button for time lt full turn slates time par 72 connected to I1 up initiates slates turning towards end 180 degree position until push button is released Clicking push button for time lt full turn slates time par 72 connected to 12 down initiates shutter down movement If the shutter
14. ure sensor to module that has already been included you first have to exclude module Connect the sensor and re include the module Module Exclusion Reset from Z Wave network Connect module to power supply Removing bring module within maximum 1 meter 3 feet of the main controller o enable add remove mode on main controller 2 press service button S for more than 6 second or press push button I1 five times within 3s 5 times change switch state within 3 seconds in the first 60 seconds after the module is connected to the power supply By this function all parameters of the module are set to default values and own ID is deleted If service button S is pressed more than 2 and less than 6 second module is excluded but configuration parameters are not set to default values Association Association enables Flush shutter module to transfer commands inside Z wave network directly without main controller to other Z Wave modules Associated Groups Group 1 default reporting group reserved for the main controller Group 2 basic on off triggered at change of the input l1 state and reflecting its state up to 16 nodes Group 3 basic on off triggered at change of the input 12 state and reflecting its state up to 16 nodes Group 4 multilevel triggered at changes of value of the Flush shutter position up to 16 nodes Group 5 multilevel triggered at changes of value of slats tilting position up to 16 nodes