BreezeMAX ® PRO 5000 CPE Product Manual
Contents
1. Not Authenticated EAP TTLS EAP TLS Figure 4 9 Registration Page The Registration page enables to set the following parameters After setting the parameters click Apply The changes are saved and the Registration Show page is displayed If reboot is required a message is displayed at the bottom of the page E User Name consists of 1 to 32 printable characters case sensitive The default User Name is CPEMACaddress WiMax com This is a mandatory parameter the User Name must be defined during the installation process for proper authentication and service provisioning The new user name is applied only after rebooting the unit E Password the user password for registration consists of 1 up to 32 printable characters case sensitive The new password is applied only after rebooting the unit BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation Registration Parameters E Organization Select this option to enter the name of the organization customer using the unit This parameter is optional and is intended for optional use by the Network management System The Organization Name can include up to 32 printable characters E Address use this field to enter the location of the unit This parameter is optional and is intended for optional use by the Network management System The Address can include up to 32 printable characters E Country use this field to enter the name of the count
2. End Rx Frequency KHz Depends on Radio Band and Bandwidth Scanning Main Step 2 5 MHz Discrete Scanning Frequencies Null empty list BreezeMAX PRO 5000 CPE Product Manual Chapter 3 Commissioning Configuring Basic Parameters x 3 2 2 J23 NOTE Most parameters are changed to their new values only after reset refer to Section 4 14 for more details Once the basic parameters are configured the unit should be reset in order to activate the new configuration Configuration Tools The SUs include a Web Configuration Server providing a web based GUI for local configuration and monitoring The Web Configuration Server can be accessed using a PC Notebook with a web browser The SU may be delivered with the operator s default settings already configured in the FLASH memory If there is need to change these settings then the only parameters that should be configured are the end user s credentials User Name and User Password Using the Web Configuration Server To configure the SU s basic parameters 1 Connect a PC Notebook with a web browser to the Ethernet port of the SU using a straight Ethernet cable 2 Configure the PC s IP parameters to enable connectivity with the unit The IP address of the SU for local management access is 192 168 254 251 The Subnet Mask is 255 255 255 0 The recommended IP address for the PC is 192 168 254 250 as this is also the default TFTP Sever IP
3. Grounding cable with an appropriate termination Installation tools and materials including appropriate means e g a 1 to 4 pole for installing the ODU BreezeMAX PRO 5000 CPE Product Manual Chapter 2 Installation Installing the ODU of the PRO CPE 2 1 1 3 Optional Items E Tilt Pole Mounting tz Ed NOTE Items marked with an asterisk are available from Alvarion 2 1 2 Guidelines for Positioning the ODU This section provides key guidelines for selecting the optimal installation locations for the ODU CAUTION A ONLY experienced installation professionals who are familiar with local building and safety codes and wherever applicable are licensed by the appropriate government regulatory authorities should install outdoor units and antennas Failure to do so may void the product warranty and may expose the end user or Service Provider to legal and financial liabilities Alvarion and its resellers or distributors are not liable for injury damage or regulation violations associated with the installation of Outdoor Units or antennas Select the optimal locations for the equipment using the following guidelines E The ODU should be mounted on a 1 4 pole Its location should enable easy access to the unit and its connectors for installation and testing E The higher the placement of the ODU the better the achievable link quality E The ODU should be installed to provide a direct or near line of sight with the B
4. BreezeMAX PRO 5000 CPE Q Product Manual Chapter 4 Operation Management Parameters 4 12 Management Parameters Management Parameters 6 N A E 10 11 12 13 12 13 14 15 Not Connected Figure 4 20 Management Page The Management page enables viewing the parameters related to remote over the air management of the device and to set the DSCP classifier The following parameters are displayed Factory Defaults DSCP Classifier Actual Used DSCP Classifier the DSCP classifier used when the CPE is connected When the CPE is not connected the value is N A Configured DSCP to change enter a value and click Apply Range 0 63 Default 6 Management IP Address acquired from a DHCP server during Network Entry eCPE Manager IP Address acquired from a DHCP server or Not Available eCPE Manager Connection Status Up Down or Not Connected BreezeMAX PRO 5000 CPE 7 Product Manual Chapter 4 Operation Logout 4 13 Logout To log out click on the Logout menu The following window is displayed Logout Logout Cancel Figure 4 21 Logout Page Click on the Logout button The Login page is displayed BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation 4 14 Parameters Summary Table 4 3 SU Parameters Summary Parameters Summary Parameter Range Default Run Time Updated Unit Control Parameters Password Up to 20 printable c
5. Chapter 6 EENS uecht AA eEag ENEE 40 4 1 Introduction to SU ManagemeEnt rei 42 4 2 Accessing the Web Configuration Server rrcciiiiiiiiie 43 4 3 Using the Web Configuration Server rcreiiiii iii 44 44 SIA 45 4 5 Unit Control Parametets cilindri 46 45 1 piede 46 4 52 Reset UNN irlandese 48 453 Change Password laicit 49 4 5 4 SW Versions lr E 50 4 5 5 Configuration en E 52 45 6 H Oe EE 54 4 5 7 Ethernet Op Modella 55 4 6 Registration Patametets a 57 BGA Maiellaro 57 46 2 Registration EE 58 4 7 BSVAU Farage serge gege IR taana anandia eaan i aandaa aa ausra a natania nai 61 4 8 Radio Parametets urna 65 48T pila air 65 4 8 2 Frequency Scanning ssssseeeessseesssrrrsserrrrtrrrnttsstrrrssrrnnnettnnntttnnnnstrrrneeenn nenene 65 BreezeMAX PRO 5000 CPE Product Manual Contents 4 8 3 Antenna Selection i 69 4 9 ATPC Paraneteis Ra 70 E israeliane 70 492 EE 71 4 10 Performance MOnitor ii 73 4 10 1 Link Quality Counters Page AEN 73 4 10 2 Ethernet COLUNTENS ciilirlcaeaaania 74 4 10 3 Integration LEE 75 4 11 Service Parameters EN 77 4 12 Management Parameters snnnnsnunnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnmnnn nnmnnn 79 4 19 e e E 80 4 14 ParametersSummal iceciiiiceililezieialilaaaiaarleti 81 A 1 PRO CPE Troubleshooting cucini
6. Ice Loading 25mm radial ice density 7kN m3 Solar Radiation IEC 68 2 5 MIL STD 810D Wind Speed 160Km Hr required for antenna stability under operation 1 3 7 Standards Compliance General Type Standard EMC E FCC Part 15B Class B E EN 55022 Class B E EN 301 489 1 4 Safety HM UL 60950 1 22 E IEC EN 60950 1 22 Telecom E ITU T K21 BreezeMAX PRO 5000 CPE Product Manual Chapter 1 Products Description Specifications Type Standard Standards E EN 302 326 E EN 302 085 V1 2 2 2003 08 Range 1 E EN 301 893 v1 5 1 E FCCp 27 E IEEE 802 3 2005 10BASE T and 100BASE TX BW FCC 06 96A1 WiMAX Radio Signal E IEEE 802 16e 2005 WAVE 1 and WAVE 2 Certification 1 3 8 Physical and Electrical 1 3 8 1 Mechanical Table 1 8 Mechanical Specifications Unit Dimensions cm Weight kg CPE IDU 156mm L X 60mm W X 33mm T 0 3 CPE ODU PRO SA 230mm H X 230mm W X 63mm T 2 1 3 8 2 Electrical Table 1 9 Electrical Specifications Item Details Power Consumption 16 5W CPE IDU Power Input 100 240 VAC 47 63 Hz CPE ODU PRO Power Input 54 VDC from the IDU over the indoor outdoor Ethernet cable BreezeMAX PRO 5000 CPE Product Manual Chapter 1 Products Description 1 3 8 3 Connectors Table 1 10 Connectors Specifications Unit Connector Details CPE IDU 1D ETHERNET 10 100Base
7. length of the IDU ODU cable should not exceed 100 meters 8 Verify proper operation as described in the applicable section of Chapter 3 BreezeMAX PRO 5000 CPE Product Manual Chapter 2 Installation Installing the IDU 1D Indoor Unit of the PRO 5000 CPE 2 2 6 Grounding the ODU IDU Cable Follow the instructions below to ground the ODU IDU cable The following paragraphs describe one method for grounding the outdoor rated Category 5E Ethernet cable through its drain wire The actual connection method employed is left to the professional installer gt To ground the ODU IDU Ethernet cable follow these steps 1 Strip back about a one inch 2 4 cm section of the Ethernet cable jacket to expose the drain wire Drain Wire 2 Attach a grounding cable to the drain wire and then connect it to protective earth 3 Use weatherproof tape to cover and seal the attachment area on the Ethernet cable BreezeMAX PRO 5000 CPE Product Manual crac A a Commissioning Chapter 3 Commissioning In This Chapter Commissioning Steps on page 31 Configuring Basic Parameters on page 32 SU Alignment Unit SAU on page 35 Using SAU for Aligning the PRO CPE s Antenna on page 37 Operation Verification on page 39 BreezeMAX PRO 5000 CPE Product Manual Chapter 3 Commissioning Commissioning Steps Sc Commissioning Steps After completing the installation process as described
8. 19 31 v 192 e L 250 Perform Action Figure 4 6 TM amp PM File Upload Control Page The TM amp PM File Upload Control page includes the following fields buttons E TM amp PM Files select from the available TM and PM files from the drop down menu for uploading to the TFTP server M Local TFTP Server IP Address enter the local TFTP server IP address from which to upload the TM and PM files E Perform Action click to initiate the upload procedure 4 5 7 Ethernet Op Mode The Ethernet Port control parameter enables viewing and defining the operation mode of the Ethernet port Current Parameters and Status Enable 100 Mbps Full duplex Disable Enable 10 Mbps Half duplex e Figure 4 7 Ethernet Operation Mode Page The Ethernet Operation Mode page includes the following fields The read only fields display the current configured parameters The configurable fields enable to set a different value for these parameters E Auto Negotiation enable disable Auto Negotiation The default is Enable BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation Unit Control Parameters E Speed and Duplex If Auto Negotiation is set to Enable this field is greyed out If set to Disable this parameters allows selecting one of the following options 10Mbps Half Duplex 10Mbps Full Duplex 100Mbps Half Duplex 100Mbps Full Duplex E Ethernet Down Timeout Enables to configure Ethe
9. 3 SAU LINK QUALITY LEDs Functionality Bar LEDs SNR LED 1 green is On Wireless link is established LED 2 green is On 5dB lt SNR lt 9dB LEDs 2 3 green are On 10dB lt SNR lt 14dB LEDs 2 4 green are On 15dB lt SNR lt 19dB LEDs 2 5 green are On 20dB lt SNR lt 23dB LEDs 2 6 green are On SNR gt 240B and RSSI lt 72dBm LEDs 2 7 green are On SNR gt 240B and RSSI gt 72dBm LEDs 2 8 green are On SNR gt 240B and RSSI gt 69dBm LEDs 2 9 green are On SNR gt 240B and RSSI gt 60dBm LEDs 2 10 green and 9 red are On RSSI gt 21dBm saturation LEDs 2 10 Blinking one after the other During full frequency scan LEDs 2 10 Blinking as follows LED 6 lights after 200ms LEDs 7 amp 5 light after 200ms LEDs 8 amp 4 light after 200ms LEDs 9 amp 3 light after 200ms LEDs 10 amp 2 light after 200ms all the LEDs are extinguished and then the sequence is repeated During Best AU selection process or short scan 3 3 2 Using SAU for Aligning the PRO CPE s Antenna The LINK QUALITY bar display on the SAU comprises 9 LEDs E The WLNK LED indicates that the wireless link is active and is lit when the SU has completed the Network Entry process E LEDs 1 to 8 green and 9 red indicate the quality of the received signal The higher the number of LEDs illuminating the better the quality of the re
10. 4 1 3 Specifications Rea 5 UC Riace 5 2 Sdi elica 6 1 3 3 IDU ODU Communication EE 6 1 3 4 Data Communication Ethernet Port 6 1 3 5 Configuration and Management 7 1 3 6 HERE siidine aaaea aaa AAAA AE Aie aRar ii 8 1 3 7 Standards Compliance Genera 8 1 3 8 Physical and Elecirical c sleale 9 LIPARI id 2 1 Installing the ODU of the PRO CPE iii 13 2 1 1 CPE Installation Requirement ii 13 2 1 2 Guidelines for Positioning the OD 14 2 1 3 IDI ODU Cade 15 2 1 4 Pole Mounting the OD 15 24 5 COMES 20 2 1 6 Connecting EE 20 2 2 Installing the IDU 1D Indoor Unit of the PRO 5000 CPE 24 2 2 1 Installation Ee Uu 24 222 E 10 CR aa ITA 24 2 2 3 CPE IDU 1D Connectors and LEDS 25 224 RESET BU eee 26 2205 IDU nsiglalioi said 26 2 2 6 Grounding the ODU IDU Gable i iii 28 BreezeMAX PRO 5000 CPE Product Manual Contents UR 29 3 1 Commissioning SiepS Lula ected cece 31 3 2 Configuring Basic ParametersS rrricie iii 32 3 2 1 The Basic E a iano 32 3 2 2 Configuration RE issn e EE EE AEREE ERS 33 3 2 3 Using the Web Configuration Server ii 33 3 3 Aligning the PRO CPE s Antenha Jia 35 3 0 1 SU Alignment Unit SAUL 35 3 3 2 Using SAU for Aligning the PRO CPE s Antenna 37 3 4 Operation Verificationi 1 Faina 39
11. 4 Data Communication Ethernet Port Table 1 4 Data Communication Ethernet Port Standard Compliance IEEE 802 3 CSMA CD Maximum Packet Size including 4 CRC bytes 1522 Bytes Speed 10 100 Mbps Half Full Duplex with Auto Negotiation BreezeMAX PRO 5000 CPE Product Manual Chapter 1 Products Description Specifications 1 3 5 Configuration and Management Table 1 5 Configuration and Management Item Description Management options E Web based HTTP HTTPS E TR 069 E TFTP Management access From Wired LAN Wireless Link Management access protection Access Password Allocation of IP parameters E LAN Configurable M WAN DHCP options 43 60 Software upgrade HTTP TFTP Configuration Upload Download HTTP Authentication TLS TTLS BreezeMAX PRO 5000 CPE Product Manual Chapter 1 Products Description Specifications 1 3 6 Environmental 1 3 6 1 IDU Table 1 6 Environmental Specifications Item Details Operating Temperature 5 C to 45 C Storage Temperature 40 to 75 C Humidity Maximum 95 non condensing 1 3 6 2 ODU Table 1 7 Environmental Specifications Item Details Operating Temperature 40 C to 55 C Storage Temperature 40 to 70 C Humidity Maximum 95 non condensing Rain IEC 67 Random Vibration IEC 68 2 64 Shock IEC 68 2 29 Salt Fog IEC 68 2 11
12. Antenna Selection Pdf flo hear 69 KS Ee ei 70 ATPG e ee ee ee eee ee ee 71 Link Quality Counters Page 73 Ethernet Counters Page AAA 74 Product Manual Figures Figure 4 18 Integration Time Page nnne 75 Figure 4 19 Service e E 77 Figure 4 20 Management Rage 79 Figure 4 247 Logout Page 80 BreezeMAX PRO 5000 CPE Product Manual Tables Tables Table 1 1 Radio SpecifiCationSs i 5 Table 1 2 Sensitivity E 6 Table 1 3 ODU ODU Communication REENEN 6 Table 1 4 Data Communication Ethernet Pott 6 Table 1 5 Configuration and Management ne 7 Table 1 6 Environmental Specifications AEN 8 Table 1 7 Environmental EE 8 Table 1 8 Mechanical SpecificationSs i 9 Table 1 9 Electrical Specifications nia iaia 9 Table E Da Eeer 10 Table 2 1 Approved Category 5E Ethernet Cables kuk 15 Table 2 2 CPE ODU PRO Connectors iii 20 Table ee E 22 Table 2 4 CPE IDU 1D Connectors 25 ler EE riali 26 Table 3 1 SU s Basic Parameters ken 32 Table 3g 2 EE 36 Table 3 3 SAU LINK QUALITY LEDs Functionality 37 Table 4 1 Intermediate SIEps iiuiiiir ia 66 Table tu e de E 72 Table 4 3 SU Parameters Gummanm ii 81 BreezeMAX PRO 5000 CPE Product Manual copie i se Products Description Chapter 1 Products Description In This Chapter E BreezeMAX CPEs on page 3 E Introduci
13. City Taipei County Taiwan R O C Attn Eva Lin Tel 886 2 2832 3339 Fax 886 2 2206 0081 E mail eva south bay com tw Teldor 8393204101 www teldor com Southbay Holdings Limited TSM2404A0D GU Tech LLC A Member of OVIS GroupTel Fax 732 918 8221 Mobile 718 909 4093 www OVIS COM TW www GU TECH COM 2 1 4 In case of missing information in the manufacturer s WEB site product specifications ordering issues etc it is highly recommended to contact the manufacturer s sales representative directly Pole Mounting the ODU The ODU can be mounted on a 1 to 4 pole using one of the following options E A pole mounting kit is supplied with each unit The kit includes a special clamp and a pair of threaded rods flat washers spring washers and nuts There are two pairs of threaded holes on the back of the unit enabling to use BreezeMAX PRO 5000 CPE Product Manual Chapter 2 Installation Installing the ODU of the PRO CPE the mounting kit for installing the unit using either vertical or horizontal polarization The clamp enables installing the unit on diverse pole diameters from 1 to 4 E A Tilt Pole Mounting kit providing a tilt range of 15 is available The Tilt kit can be attached to the ODU and be mounted on a 1 to 4 pole using two 9 16 wide metal bands 2 1 4 1 Pole Mounting the ODU Using the Clamp Figure 2 1 and Figure 2 2 illustrate how to mount an ODU on a pole using the cla
14. ODU and this may harm other equipment connected to it 3 Connect the power cord to the unit s AC socket located on the rear panel Connect the other end of the power cord to the AC mains after verifying that the unit is rated for the voltage in the country of use the AC range is indicated on the back side of the CPE IDU 1D x NOTE The color codes of the power cable are as follows Brown Phase Blue Neutral 0 Yellow Green Ground amp 4 Tocomply with safety regulations the shield of the ODU IDU outdoor rated Ethernet cable must be connected to protective ground earth The grounding point can be either inside the building or immediately at the entry point to the building depending on where a protective ground is available CAUTION A Grounding the ODU IDU Ethernet cable must be performed by a professional installer in conformance with local safety regulations 5 Verify that the POWER LED located on the front panel is lit indicating that the unit is supplying power to the radio port 6 Configure the basic parameters and align the antenna as described in the applicable sections of Chapter 3 7 Connect the 10 100 Base T ETHERNET connector s to the data equipment The cable connection should be a crossed Ethernet if connecting to a hub switch and a straight cable if connecting directly to a PC Network Interface Card NIC Ed NOTE The length of the Ethernet cable connecting CPE IDU 1D to the user s equipment together with the
15. T RJ 45 Cable connection to a PC StraightCable connection to a hub Crossed RADIO 10 100Base T RJ 45 AC IN 3 pin AC power plug CPE ODU PRO SA IDU COM 10 100Base T RJ 45 SAU Special mini USB BreezeMAX PRO 5000 CPE Product Manual chante LU Installation Chapter 2 Installation In This Chapter E Installing the ODU of the PRO CPE on page 13 E Installing the IDU 1D Indoor Unit of the PRO 5000 CPE on page 24 BreezeMAX PRO 5000 CPE O Product Manual Chapter 2 Installation Installing the ODU of the PRO CPE Sch 2 11 2 1 1 1 2 1 1 2 Installing the ODU of the PRO CPE The following sections describe how to install the outdoor unit ODU of the PRO CPE CPE Installation Requirements Packing List The PRO CPE includes the following components ODU Package CPE ODU unit with integrated antenna Mounting kit Quick Installation Guide Optional software utilities and User Guide CD IDU Package CPE IDU unit comprising of AC power adapter and internal gateway Power Cable Package AC DC power cable Additional Installation Requirements The following items are also required to install the ODU Double shielded Cat 5E outdoor ethernet cable with two RJ 45 connectors 90m see Section 2 1 3 for details on approved cables and maximum length and an RJ 45 connectors crimping tool SAU SU Alignment Unit for antenna alignment and status verification
16. are defined as follows NOTE d In the current version intermediate steps are disabled Table 4 1 Intermediate Steps Step Effect on scanned frequencies set when Step is Enabled BO Scan Start Frequency Start Frequency is added to the set of Main Frequencies B1 Intermediate Step 125 KHz All intermediate frequencies defined by Main Frequency 125 KHz are added to the scanning set B2 Intermediate Step 250 KHz All intermediate frequencies defined by Main Frequency 250 KHz are added to the scanning set B3 Intermediate Step 375 KHz All intermediate frequencies defined by Main Frequency 375 KHz are added to the scanning set B4 Intermediate Step 500 KHz All intermediate frequencies defined by Main Frequency 500 KHz are added to the scanning set B5 Intermediate Step 625 KHz All intermediate frequencies defined by Main Frequency 625 KHz are added to the scanning set B6 Intermediate Step 750 KHz All intermediate frequencies defined by Main Frequency 750 KHz are added to the scanning set B7 Intermediate Step 875 1250 KHz All intermediate frequencies defined by Main Frequency 1250 KHz are added to the scanning set For example If Steps BO B1 and B4 are enabled and all other steps are disabled the scanned frequencies are Start Frequency Start Frequency 125 KHz Start Frequency 500 KHz Start Frequency N Main Step Start Fre
17. desired analog or digital data signal to the amplitude of noise in a transmission channel at a specific point in time SNR is typically expressed logarithmically in decibels dB SNR measures the quality of a transmission channel or a signal over a network channel The greater the ratio the easier it is to identify and subsequently isolate and eliminate the effects of noise SNR also is abbreviated as S N Subscriber Unit Transmission Control Protocol Connection oriented transport layer protocol that provides reliable full duplex data transmission TCP is the part of the TCP IP suite of protocols that is responsible for forming data connections between nodes that are reliable as opposed to IP which is connectionless and unreliable Transmission Control Protocol Internet Protocol A set of protocols developed by the U S Department of Defense to allow communication between dissimilar networks and systems over long distances TCP IP is the de facto standard for data transmission over networks including the Internet Time Division Duplex is a duplexing technique dividing a radio channel in time to allow downlink operation during part of the frame period and uplink operation in the remainder of the frame period Trivial File Transfer Protocol Simplified version of FTP that allows files to be transferred from one computer to another over a network usually without the use of client authentication TR 069 CPE WAN Management Protocol CWMP w
18. in the preceding chapter several actions should be performed to ensure connectivity with a BTS and provisioning of services After the SU is connected with a BTS it can be fully managed via the wireless link 1 The basic parameters must be configured to ensure that the unit operates correctly and can communicate with a BTS 2 The antenna must be aligned to ensure optimal performance of the wireless link 3 Proper operation should be verified including data connectivity BreezeMAX PRO 5000 CPE Product Manual Chapter 3 Commissioning i Configuring Basic Parameters Configuring Basic Parameters 3 2 1 The Basic Parameters Table 3 1 SU s Basic Parameters Parameter Default Value Comment Country Code Must be set in accordance to designated country and deployment scenario Ethernet Port auto Negotiation Enable Disable Enabled Ethernet Port Speed and Duplex Applicable only if Ethernet Auto Negotiation Enable Disable is set to Disable User Name CPEMACaddress WiMax com Should be supplied by system administrator operator User Password Empty Should be supplied by system administrator operator Organization Empty Address Empty Country Empty BST AU ID 0 0 0 0 0 0 BST AU ID Mask 0 0 0 0 0 0 Preferred BST AU ID 0 0 0 0 0 0 Preferred BST AU ID Mask 0 0 0 0 0 0 Bandwidth Auto 5 10 MHz Start Rx Frequency KHz Depends on Radio Band and Bandwidth
19. link Link Quality Historical 1 Min Counters Integration times 15 Min Counters Ethernet Historical 1 Min Counters Integration times Apply 15 Min Counters Figure 4 18 Integration Time Page The Link Quality Historical table enables to define a time period for monitoring the WiMAX WAN port link to either 1 or 15 minutes The Ethernet Historical table enables to define a time period for monitoring the Ethernet LAN port link to either 1 or 15 minutes BreezeMAX PRO 5000 CPE 75 Product Manual Chapter 4 Operation Performance Monitor To set the time period select the required option and click Apply BreezeMAX PRO 5000 CPE O Product Manual Chapter 4 Operation Service Parameters 4 11 Service Parameters The Service Parameters page enables viewing the service related parameters configured via the BTS Show All parameters Service Parameters Service Line Count 1 Operation Mode IPCS Service definition Figure 4 19 Service Page The Service Parameters page displays the following E Service Line Count this is the number of configured services and corresponds to the number of service rules in the Service Definition table E Operation Mode displays the convergence sublayer CS in the wireless access network IP CS DSCP based classification or Ethernet CS VLAN based classification E Service Definition table displays the Service Rules to be used for handling the relevant class
20. the following Chinese legislation Management methods for Controlling Pollution by Electronic Information Products No 39 also known as China RoHS BreezeMAX PRO 5000 CPE vi Product Manual Important Notice Important Notice This user manual is delivered subject to the following conditions and restrictions This manual contains proprietary information belonging to Alvarion Ltd Such information is supplied solely for the purpose of assisting properly authorized users of the respective Alvarion products No part of its contents may be used for any other purpose disclosed to any person or firm or reproduced by any means electronic and mechanical without the express prior written permission of Alvarion Ltd The text and graphics are for the purpose of illustration and reference only The specifications on which they are based are subject to change without notice The software described in this document is furnished under a license The software may be used or copied only in accordance with the terms of that license Information in this document is subject to change without notice Corporate and individual names and data used in examples herein are fictitious unless otherwise noted Alvarion Ltd reserves the right to alter the equipment specifications and descriptions in this publication without prior notice No part of this publication shall be deemed to be part of any contract or warranty unless specifically incorporated by refe
21. the new password and re enter the new password for confirmation Then click Save New Password Click Refresh to clear the fields Ed Notify the administrator of the new password Valid passwords 1 to 20 printable characters case sensitive Default password installer BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation Unit Control Parameters 4 5 4 SW Versions Control SW Versions Control K2_4_6_4_35 app 4 6 4 35 K2_4_6_4_34 app 4 6 4 34 Main 192 l fies k 254 250 192 168 254 250 k2_0021 0_Firmware bz SW Download Reset and Run from Shadow Set Running Version as Main _Reftesh Figure 4 4 SW Versions Control Page The SU can contain two SW versions Main Normally each time the SU resets it will reboot using the version defined as Main Shadow Normally the Shadow version is the backup version Each time a new SW File is downloaded to the SU it will be stored as a Shadow version replacing the previous Shadow Version The typical process of upgrading to a new SW version includes the following steps 1 2 Download the new SW file to the SU It will be stored as the Shadow version Reset and run the unit from its Shadow version Note that if the new SW file was loaded from StarACS the Run from Shadow operation will be performed automatically If the unit succeeded to complete network entry the Shadow and Main versions will be swapped automatically The currently ru
22. the unit E End Rx Frequency KHz the highest frequency in the range of frequencies to be scanned in KHz The available values depend on the radio band of the unit E Scanning Main Step MHz the Main Scanning Step that together with the Intermediate Scanning Steps define the frequencies to be scanned between the Start and End Rx Frequencies The main steps can be 2 5 MHz or 5 MHz The default is 2 5 MHz E Scanning Intermediate Steps KHz the Intermediate Scanning Steps that together with the Main Scanning Step define the frequencies to be scanned between the Start and End Rx Frequencies The Intermediate Scanning Steps include 8 Steps that define the intermediate scanning steps as described above The default is Enable for the BO Start Frequency Scan NOTE In the current version intermediate steps are disabled E Bandwidth enables to select either a specific bandwidth according to the options supported by the unit or scan all supported bandwidths Auto The default is Auto mode To change the bandwidth select the required bandwidth from the list and click Apply A reset required message is displayed Click OK to reset the unit or Cancel to cancel the operation E Discrete Frequencies enables editing the list of discrete frequencies that will be included in the Frequency Scanning Table If no discrete frequency has been added N A will be displayed To delete a discrete frequency from the list BreezeMAX PR
23. Address required for downloading SW versions and for downloading uploading configuration files 3 Open a web browser and connect to http 192 168 254 251 The Enter the Password prompt is displayed Enter the password and press the Enter key NOTE The default password is installer BreezeMAX PRO 5000 CPE Product Manual Chapter 3 Commissioning Configuring Basic Parameters Please Enter Password LOGIN Figure 3 1 Login Window 4 The Main window of the Web Configuration Server is displayed enabling access to the required parameters configuration and performance monitoring options Refer to Chapter 4 for instructions on using the Web Configuration Server and detailed information on the various parameters and other features supported 5 Configure the basic parameters listed in Table 3 1 6 Reset the unit to apply the new settings and enable synchronization with a BS BreezeMAX PRO 5000 CPE Product Manual Chapter 3 Commissioning Aligning the PRO CPE s Antenna 3 3 Jal Aligning the PRO CPE s Antenna SU Alignment Unit SAU The miniature SU Alignment Unit can be used during installation and testing to support an easy process of antenna alignment and provide the ODU s status indications To connect the SAU to the ODU 1 Remove the sealing cap of the ODU s SAU connector 2 Connect the cable attached to the SAU to the SAU connector 3 After completing the installation disconnect the cabl
24. DAMAGE HIGH RISK ACTIVITIES HIGH RISK ACTIVITIES MAY INCLUDE BUT ARE NOT LIMITED TO USE AS PART OF ON LINE CONTROL SYSTEMS IN HAZARDOUS ENVIRONMENTS REQUIRING FAIL SAFE PERFORMANCE SUCH AS IN THE OPERATION OF NUCLEAR FACILITIES AIRCRAFT NAVIGATION OR COMMUNICATION SYSTEMS AIR TRAFFIC CONTROL LIFE SUPPORT MACHINES WEAPONS SYSTEMS OR OTHER APPLICATIONS REPRESENTING A SIMILAR DEGREE OF POTENTIAL HAZARD ALVARION SPECIFICALLY DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR HIGH RISK ACTIVITIES BreezeMAX PRO 5000 CPE Q Product Manual Legal Rights b PURCHASER S SOLE REMEDY FOR BREACH OF THE EXPRESS WARRANTIES ABOVE SHALL BE REPLACEMENT OR REFUND OF THE PURCHASE PRICE AS SPECIFIED ABOVE AT ALVARION S OPTION TO THE FULLEST EXTENT ALLOWED BY LAW THE WARRANTIES AND REMEDIES SET FORTH IN THIS AGREEMENT ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OR CONDITIONS EXPRESS OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW STATUTORY OR OTHERWISE INCLUDING BUT NOT LIMITED TO WARRANTIES TERMS OR CONDITIONS OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE SATISFACTORY QUALITY CORRESPONDENCE WITH DESCRIPTION NON INFRINGEMENT AND ACCURACY OF INFORMATION GENERATED ALL OF WHICH ARE EXPRESSLY DISCLAIMED ALVARION WARRANTIES HEREIN RUN ONLY TO PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES ALVARION NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE INSTALLA
25. EDs illuminate Configuration problem Verify proper configuration of Frequency Scanning parameters Verify proper configuration of BS ID parameters If proper configuration parameters are not known press the RESET button for more than 5 seconds to activate the factory default configuration Poor link quality Try changing the location of the unit antenna to improve link quality using the LINK QUALITY LEDs Signal is too strong All LINK QUALITY LEDs including the red LED are on Signal is too strong may cause saturation Change the location direction of the unit antenna to reduce signal strength using the LINK QUALITY LEDs Authentication Failure LED 1 ELNK orange of the LINK QUALITY bar blinks Authentication problem Enter User Name and User Password and reset the unit If the problem persists contact the operator BreezeMAX PRO 5000 CPE Product Manual Glossary Glossary AAA ACS AES CCM APD ARP ATPC AWGN BPSK BS BTS BWA CF CINR CLI CPE CPU BreezeMAX PRO 5000 CPE Authentication Authorization and Accounting pronounced triple a A system or several systems that controls what resources users have access to and keeps track of the activity of users over the network Auto Configuration Server ACPE management system supporting secure auto configuration as well as other CPE management functions Advanced Encryption Standard Cou
26. Mobile WiMAX after the WiMAX forum for interoperability 802 16e based on an existing WiMAX standard 802 16a adds WiMAX mobility in the 2 to 6 GHz licensed bands 802 16e allows for fixed wireless and mobile Non Line of Sight NLOS applications primarily by enhancing the OFDMA Orthogonal Frequency Division Multiple Access Internet Protocol The standard that defines how data is transmitted over the Internet IP bundles data including e mail faxes voice calls and messages and other types into packets in order to transmit it over public and private networks Local Area Network A computer network limited to a small geographical area such as a single building The network typically links PCs as well as shared resources such as printers Light Emitting Diode Standardized data link layer address that is required for every port or device that connects to a LAN Other devices in the network use these addresses to locate specific ports in the network and to create and update routing tables and data structures MAC addresses are 6bytes long and are controlled by the IEEE a Product Manual Glossary MCS MMDS MSCHAP MSS NA NE NIC ODU OFDM OFDMA PER PHY BreezeMAX PRO 5000 CPE Multipoint Communications Systems Applications licensed at 2500 MHz in Canada A wide variety of applications are possible including one way and two way transmission and a diversity of distribution capacities Multichannel Multipoi
27. Mobility Mode E Nomadic Nomadic Yes E Mobile Radio Parameters Start Rx Frequency KHz Per country code Per country code Yes after Update Resolution for all bands is e Scanning Table 0 125 MHz End Rx Frequency KHz Per country code Per country code Yes after Update Resolution for all bands is Scanning Table 0 125 MHz Scanning Main Step MHz E 2 5 MHz 2 5 MHz Yes after Update E 5 MHz Scanning Table Set Bandwidth to Scan E 5 MHz Auto Yes E 10 MHz E Auto Multirate and ATPC Parameters ATPC E Enable Enable Yes E Disable BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation Table 4 3 SU Parameters Summary Parameters Summary Parameter Range Default Run Time Updated Set Tx Power 21 to 26 Last power used by Yes ATPC Management Configured DSCP Classifier 0 63 6 No BreezeMAX PRO 5000 CPE Product Manual Appendix VAN D Troubleshooting Appendix A Troubleshooting In This Appendix E PRO CPE Troubleshooting on page 86 BreezeMAX PRO 5000 CPE Product Manual Appendix A Troubleshooting Al PRO CPE Troubleshooting PRO CPE Troubleshooting Refer to the BreezeMAX Troubleshooting Guide for additional information on troubleshooting Problem and Indication Possible Cause Corrective Action Power Failure None of the IDU LEDs illuminate after connecting to power Mains power problem Verify mains power
28. O 5000 CPE Product Manual Chapter 4 Operation Radio Parameters 4 8 3 first selecting the frequency to be deleted and click Delete select The Delete select button is available only if at least one discrete frequency is added M Delete All Discrete Frequencies to delete all discrete frequencies click on Delete All E Discrete Scanning Frequencies enables to enter discrete frequencies as follows Update List of Discrete Frequencies Enter a list of up to 10 discrete frequencies in steps of 2 5MHz separated by commas no space This list will replace the current list of discrete frequencies Add One Discrete Frequency Enter one frequency to be added to the current list of discrete frequencies E Update Scanning Table select this option to update the frequency scanning table in run time without resetting the unit M Clear Best BS Table select this option to clear the current Best BS Table Typically this should be done prior to initiating a full scanning process see below E Force Full Scanning select this option to initiate a full scanning process Antenna Selection Antenna Selection Radio Status 2R 1T Si ODU not switching antenna Antenna No selection Figure 4 13 Antenna Selection Page The Antenna Selection page enables viewing the parameters of the integrated antenna The following parameters are displayed E Radio Status E Antenna enables selection of antenna Currently only one i
29. Requirements for Cryptographic Modules is a United States security standard used to certify cryptographic modules File Transfer Protocol A protocol for exchanging files over the Internet FTP uses the Internet s TCP IP protocols to enable data transfer Graphical User Interface In a GUI operating system the user responds to graphic images on the screen instead of typing in commands in response to a prompt HyperText Transfer Protocol The protocol used to transmit and receive data over the World Wide Web Indoor Unit Institute of Electrical and Electronics Engineers IEEE pronounced I triple E is an organization composed of engineers scientists and students The IEEE is best known for developing standards for the computer and electronics industry In particular the IEEE 802 standards for local area networks are widely followed A Local Area Network protocol suite commonly known as Ethernet Ethernet uses Carrier Sense Multiple Access bus with Collision Detection CSMA CD This method allows users to share the network cable However only one station can use the cable at a time A variety of physical medium dependent protocols are supported Also known as WIMAX A group of broadband wireless communications standards for metropolitan area networks MANs developed by a working group of the IEEE 802 16e also known as 802 16 2005 is an IEEE standard addressing mobility of wireless broadband WiMax IEEE 802 16e is sometimes called
30. TION MAINTENANCE OR USE OF ITS PRODUCTS Limitation of Liability a ALVARION SHALL NOT BE LIABLE TO THE PURCHASER OR TO ANY THIRD PARTY FOR ANY LOSS OF PROFITS LOSS OF USE INTERRUPTION OF BUSINESS OR FOR ANY INDIRECT SPECIAL INCIDENTAL PUNITIVE OR CONSEQUENTIAL DAMAGES OF ANY KIND WHETHER ARISING UNDER BREACH OF CONTRACT TORT INCLUDING NEGLIGENCE STRICT LIABILITY OR OTHERWISE AND WHETHER BASED ON THIS AGREEMENT OR OTHERWISE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES b TO THE EXTENT PERMITTED BY APPLICABLE LAW IN NO EVENT SHALL THE LIABILITY FOR DAMAGES HEREUNDER OF ALVARION OR ITS EMPLOYEES OR AGENTS EXCEED THE PURCHASE PRICE PAID FOR THE PRODUCT BY PURCHASER NOR SHALL THE AGGREGATE LIABILITY FOR DAMAGES TO ALL PARTIES REGARDING ANY PRODUCT EXCEED THE PURCHASE PRICE PAID FOR THAT PRODUCT BY THAT PARTY EXCEPT IN THE CASE OF A BREACH OF A PARTY S CONFIDENTIALITY OBLIGATIONS Radio Frequency Interference Statement The Subscriber Unit equipment has been tested and found to comply with the limits for a class B digital device pursuant to ETSI EN 301 489 1 rules and Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment notwithstanding use in commercial business and industrial environments This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordan
31. TS antenna s The ODU should be aligned to face the general direction of the BTS E In some cases it might be necessary to up down tilt the antenna An optional Tilt accessory for the ODU providing a tilt range of 15 is available The tilt option may be necessary to either improve the link conditions or if the SU is too close to the BTS to reduce the receive signals strength As a rule of thumb if the SU is located at a distance of less than 300 meters from the BTS it is recommended to up tilt the antenna by approximately 10 to 15 especially in line of sight conditions to avoid saturation of the receivers by too strong signals BreezeMAX PRO 5000 CPE Product Manual Chapter 2 Installation Installing the ODU of the PRO CPE ae x IDU ODU Cables NOTE The length of the Indoor to Outdoor cable should not exceed 90 meters The length of the Indoor to Outdoor cable together with the length of the Ethernet cable connecting the CPE IDU 1D to the data equipment should not exceed 100 meters Use only Category 5E Ethernet cables from either Alvarion or any of the approved manufacturers listed in Table 2 1 Consult with Alvarion s specialists on the suitability of other cables Table 2 1 Approved Category 5E Ethernet Cables Manufacturer Part Number Superior Cables Ltd 612098 www superior cables com www hescs com HES Cabling Systems H5E 00481 11th FI 15 Lane 347 Jong Jeng Rd Shin Juang
32. al into sub channels i e groups of carriers with each sub channel or several sub channels being allocated to a different subscriber Packet Error Rate In a digital transmission PER is the percentage of packets with errors divided by the total number of packets that have been transmitted received or processed over a given time period PHYsical Layer The physical or lowest layer of the OSI Network Model In a wireless network the PHY defines parameters such as data rates modulation method signaling parameters transmitter receiver synchronization etc Within an actual radio implementation the PHY corresponds to the radio front end and baseband signal processing sections o Product Manual Glossary PPPoE QAM QPSK RADIUS RF RSSI R amp TTE Rx SAU SDARS SIP BreezeMAX PRO 5000 CPE Point to Point Protocol over Ethernet PPPOE relies on two widely accepted standards PPP and Ethernet PPPoE is a specification for connecting the users on an Ethernet to the Internet through a common broadband medium such as a single DSL line wireless device or cable modem All the users over the Ethernet share a common connection so the Ethernet principles supporting multiple users in a LAN combines with the principles of PPP which apply to serial connections Quadrature Amplitude Modulation A technique used in wireless applications to double the available bandwidth by combining two amplitude modulated signals The t
33. allation and Grounding Ensure that outdoor units antennas and supporting structures are properly installed to eliminate any physical hazard to either people or property Make sure that the installation of the outdoor unit antenna and cables is performed in accordance with all relevant national and local building and safety codes Even where grounding is not mandatory according to applicable regulation and national codes it is highly recommended to ensure that the outdoor unit and the antenna mast when using external antenna are grounded and suitable lightning protection devices are used so as to provide protection against voltage surges and static charges In any event Alvarion is not liable for any injury damage or regulation violations associated with or caused by installation grounding or lightning protection BreezeMAX PRO 5000 CPE vi Product Manual Legal Rights Disposal of Electronic and Electrical Waste Disposal of Electronic and Electrical Waste ps Pursuant to the WEEE EU Directive electronic and electrical waste must not be disposed of with unsorted waste Please contact your local recycling authority for disposal of this product CHAS mae SI 8395 X HRoHS PRAS CSW HBR RK fEFWRME Ki SS R ADE PBB PBDE Pb Cd Hg cr SRR ECKE E Ai o RRMA AN MARL Ek eu po SEIT SJ T11363 2006 HEM RHE x RAME ARENA Rara SVAN SRS F SJ 711363 2006 MEN RAB The above table provides information required under
34. arameter is used in the SW Download Configuration File Download and Configuration File Upload processes M Remote TFTP Server IP Address enter the IP address of the WAN TFTP server The default TFTP Server IP address is 192 168 254 250 E Choose Upload Download Action select the action to perform either upload or download gt To perform configuration file upload 1 Typically it is recommended to configure the IP address of the PC to 192 168 254 250 which is the default TFTP Server IP address of the unit Ifa different IP address is configured in the PC with the TFTP server configure the TFTP Server IP address to the same address 2 Enter the name of the configuration file as will appear in the TFTP server in the Configuration File Upload Name 3 Select Upload in the Choose Upload Download Action field BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation Unit Control Parameters 4 5 6 Click Perform Action To avoid unintentional actions you will be prompted to confirm the request Confirm the upload request and wait to receive a success failure message To perform configuration file download The required configuration file should be available in the TFTP Server directory in a PC connected to the unit Typically it is recommended to configure the IP address of the PC to 192 168 154 250 which is the default TFTP Server IP address of the unit Ifa different IP address is configured in the PC with the TFTP se
35. as created by the DSL Forum to standardize management of CPEs over the Wide Area Network WAN The TR 069 protocol specifically defines a common method for CPE devices to communicate with an Auto Configuration Server ACS Transmit User Datagram Protocol Connectionless transport layer protocol in the TCP IP protocol stack UDP is a simple protocol that exchanges datagrams without acknowledgments or guaranteed delivery requiring that error processing and retransmission be handled by other protocols UDP is defined in RFC 768 Up Link Virtual Local Area Network A group of devices on one or more LANs that are configured with the same VLAN ID so that they can communicate as if they were attached to the same wire when in fact they are located on a number of different LAN segments Used also to create separation between different user groups 04 Product Manual Glossary VoIP WAN wcs WEEE WL or W L WIMAX BreezeMAX PRO 5000 CPE Voice over Internet Protocol Provides an advanced digital communications network that bypasses the traditional public switched telephone system and uses the Internet to transmit voice communication VoIP enables people to use the Internet as the transmission medium for telephone calls by sending voice data in packets using IP rather than by traditional circuit switched transmissions of the PSTN Wide Area Network A computer network that spans a relatively large geographical area Wide area n
36. ation E Off IDU is not powered or power failed E Green IDU power is OK ETH 2 Ethernet link status E Off No Ethernet connectivity has been detected between Ethernet integrity the outdoor unit and the device connected to the indoor unit s data port E Green Ethernet connectivity has been detected between the outdoor unit and the device connected to the indoor unit s data port WIRELESS 1 Wireless link status E Off SU is not associated with a BS E Green SU is connected with a BS network entry completed E Blinking Green Authentication failed 2 2 4 2 2 9 After power up the WIRELESS LED illuminates until self test is finished RESET Button The recessed RESET button is located on the front panel of the unit When pressed power to the ODU is disconnected hard reset IDU Installation To install the IDU 1 Itis assumed that the IDU ODU cable is already connected to the ODU Assemble an RJ 45 connector with a protective cover on the indoor end of the IDU ODU cable Refer to Section 2 1 6 2 for instructions on preparing the cable 2 Connect the IDU ODU cable to the RADIO connector The RADIO connector in the CPE IDU 1D is located on the front panel as shown in Figure 2 7 BreezeMAX PRO 5000 CPE Product Manual Chapter 2 Installation Installing the IDU 1D Indoor Unit of the PRO 5000 CPE CAUTION A Do not connect the data equipment to the RADIO port The RADIO port supplies DC power to the
37. availability on the power outlet to which the power supply is connected Try using a different outlet Mains power connection problem Verify that the AC jack of the power cord is connected properly to the unit Verify that the AC plug of the power cable is connected properly to the mains power outlet Unit failure Replace the IDU IDU ODU connection problem None of the SAU s indicators illuminate IDU ODU connection problem Verify that the IDU ODU cable is connected properly Unit failur Try replacing the IDU If the problem persists try replacing the IDU ODU cable If the problem persists try replacing the ODU When connected to the data equipment the Ethernet Integrity Indicator green LED is off and or the Ethernet Activity Indicator yellow LED does not blink when there should be traffic on the Ethernet port Wrong type of Ethernet cable or faulty cable If connected directly to PC use a straight cable Otherwise use a crossed cable If the problem persists try replacing the cable If a hub or switch is installed between the PC and the CPE verify first the Ethernet connection integrity between the hub switch and the PC by checking the Ethernet LEDs at the hub switch and at the PC s NIC card If not ok try replacing the cable IDU ODU cable problem Verify that the IDU ODU cable is in order and connected properly Using SAU verify that PWR LED is on and ALRM LED is
38. ble disable the ATPC mechanism and select your country code gt To enable disable the ATPC mechanism 1 Select Disable to temporarily disable ATPC for testing purposes You will be prompted to enter the requested Tx Power The available range depends on unit type radio band D The maximum Tx power may vary depending on the country code applied and on applicable regulations The default Tx Power is the last power level used before the ATPC algorithm was disabled 2 Click Apply 3 Upon completing the test enable ATPC to resume normal operation If not enabled manually ATPC will be enabled automatically after the next reset or when closing the web interface gt To select a country code BreezeMAX PRO 5000 CPE GN Product Manual Chapter 4 Operation ATPC Parameters IMPORTANT The selected Country Code must comply with applicable local radio regulations The selected Country Code may affect the maximum Tx power and also the system performance Select the required country code from the list and reset the unit to apply the new country code The Current Country Code field displays the country code that is currently used After performing reset to the unit the configured country code becomes the current country code The following are the available country codes Table 4 2 Country Codes Country Code Frequency Range MHz 4 9 GHz Universal 4900 5350 4 9 GH
39. ce with the instruction manual may cause harmful interference to radio communications BreezeMAX PRO 5000 CPE Product Manual Legal Rights FCC Radiation Hazard Warning Outdoor CPE To comply with FCC RF exposure requirements in Section 1 1307 and 2 1091 of FCC Rules the antenna be used for this transmitter must be fixed mounted on outdoor permanent structures with a separation distance of at least 120 cm from all persons and must not be co located or operating in conjunction with any other antenna or transmitter R amp TTE Compliance Statement This equipment complies with the appropriate essential requirements of Article 3 of the R amp TTE Directive 1999 5 EC Safety Considerations General For the following safety considerations Instrument means the BreezeMAX units components and their cables Caution To avoid electrical shock do not perform any servicing unless you are qualified to do so Line Voltage Before connecting this instrument to the power line make sure that the voltage of the power source matches the requirements of the instrument Radio The instrument transmits radio energy during normal operation To avoid possible harmful exposure to this energy do not stand or work for extended periods of time in front of its antenna The long term characteristics or the possible physiological effects of radio frequency electromagnetic fields have not been yet fully investigated Outdoor Units and Antennas Inst
40. ceived signal E If all LEDs including LED 9 red are on the received signal strength is too high This must be avoided preferably by up tilting the antenna As a rule of thumb if the SU is located at a distance of less than 300 meters from the BTS it is recommended to up tilt the antenna by approximately 10 to 15 gt To align the antenna BreezeMAX PRO 5000 CPE Product Manual Chapter 3 Commissioning Aligning the PRO CPE s Antenna 1 Point the antenna toward the general direction of the BTS 2 Connect the SAU to the ODU 3 Verify that the PWR power indication on the SAU is on 4 Verify that the WLNK LED indicator is on indicating that the unit is synchronized with a BS If the SU is not synchronized with a BS ensure that all parameters are configured properly If the unit is still not synchronized with a BS improve the quality of the link by changing the direction of the antenna or by placing the antenna at a higher point or in an alternate location 5 Rotate and or tilt if applicable the ODU until the maximum link quality reading is achieved If you encounter prolonged difficulty in achieving the expected link quality try to improve the reception quality by placing the ODU at a higher point or in an alternate location x NOTE Ensure that the front of the antenna is always facing the BTS However in certain conditions such as when the line of sight to the BTS is hampered better reception may be ac
41. confirm the request To perform the SW download 1 The required SW file should be available in the TFTP Server directory in a PC connected to the unit 2 Typically it is recommended to configure the IP address of the PC to 192 168 154 250 which is the default TFTP Server IP address of the unit BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation Unit Control Parameters If a different IP address is configured in the PC with the TFTP configure the TFTP Server IP Address to the same address 3 Enter the name of the SW file as called in the TFTP server as the SW File Name 4 Select Perform SW Download and confirm the download request Wait to receive a success failure message 5 Following a successful download the loaded SW version becomes the Shadow version in the unit E Reset and Run from Shadow select this option to reset the unit and run the Shadow version after power up To avoid unintentional actions you will be prompted to confirm the request M Set Running Version as Main when the unit is running the Shadow version after selecting Reset and Run from Shadow without succeeding to complete network entry the versions will not be swapped and the unit will boot from the Main version after the next reset Select this option if you want to swap versions so that the running version will become the Main version and will be the version to be used after reset To avoid unintentional actions you will be prompted t
42. ctor Make sure to do the following E Remove as small a length as possible of the external jacket Verify that the external jacket is well inside the sealing cover when connected to the unit to ensure good sealing E Pull back the shield drain wire before inserting the cable into the RJ 45 connector to ensure a good connection with the connector s shield after crimping The IDU ODU cable provides pin to pin connection on both ends The following figure shows the required wire pair connections BreezeMAX PRO 5000 CPE Product Manual Chapter 2 Installation Installing the ODU of the PRO CPE Ha Figure 2 5 Ethernet Connector Pin Assignments Data pairs are 1 amp 2 3 amp 6 Power pair proprietary solution is 4 amp 5 The color codes used in standard cables supplied by Alvarion are as listed in the following table Table 2 3 Cable Color Codes Wire color Pin Blue 1 Blue white Orange Orange white Brown Brown white Green O NO A OD Go bh Green white gt To connect the IDU ODU cable BreezeMAX PRO 5000 CPE Product Manual Chapter 2 Installation Installing the ODU of the PRO CPE 1 The seal has a special groove allowing to insert an ethernet cable with an already assembled RJ 45 connector Strip the cable sheath and crimp the RJ 45 plug 2 Insert the cable with the assembled connector through the sealing nut 3 To expose the groove lightly
43. dio transmission and reception devices and also manages the signal processing related to the air interface Broadband Wireless Access Compact Flash A popular memory card that uses flash memory to store data on a very small card Carrier to Interference plus Noise Ratio expressed in dB Command Line Interface A user interface where the user sees the command line on the monitor and a prompt that is waiting to accept instructions from the user The user types in the command the computer acts on that command and then issues a new prompt for the next instruction from the user Customer Premise Equipment Communications equipment that resides on the customer s premises Central Processing Unit Product Manual Glossary CRC CS CSMA CD CW CWMP DHCP DL DSCP EAP EAP TTLS EMC ETSI FCC FEC BreezeMAX PRO 5000 CPE Cyclical Redundancy Check A common technique for detecting data transmission errors in which the frame recipient calculates a remainder by dividing frame contents by a prime binary divisor and compares the calculated remainder to a value stored in the frame by the sending equipment Convergence Sublayer Particular protocols that are responsible for gathering and formatting higher layer information so it can be processed by the lower layers Carrier Sense Multiple Access with Collision Detection Media access mechanisms wherein devices ready to transmit data first check the channel for a ca
44. e and replace the cap Use appropriate sealing material to protect the connection against moisture and humidity Use removable sealing material such as a tar seal to enable future access to the connector Figure 3 2 SAU BreezeMAX PRO 5000 CPE Product Manual Chapter 3 Commissioning Aligning the PRO CPE s Antenna Table 3 2 SAU LEDs Name Description Functionality AL Alarm indication E Off ODU is OK diagnostic test passed Red ODU failure PW Power indication Off ODU is not powered or 3 3 VDC failure Green ODU power to SAU is OK D E D ET Ethernet link status E Off No Ethernet connectivity has been indication detected between the outdoor unit and the Ethernet integrity device connected to the indoor unit s Ethernet port E Green Ethernet connectivity has been detected between the outdoor unit and the device connected to the indoor unit s Ethernet port WLNK Wireless link status E Off The SU is not connected with a BS indication E Orange on The SU is connected with and receives services from the BS Network Entry completed Link Quality is indicated by LEDs 1 9 as described in Table 3 3 below E Blinking orange Authentication failed LEDs 6 7 and 8 on After power up of the ODU the all LEDs illuminate until self test has completed BreezeMAX PRO 5000 CPE Product Manual Chapter 3 Commissioning Aligning the PRO CPE s Antenna Table 3
45. ed AC power cord does not fit local power outlets E For configuring parameters a Portable PC Notebook and a straight Ethernet cable for configuring parameters using a web browser E Other installation tools and materials a drill for wall mounting the unit means for securing cables to walls etc Location The unit can be placed on a desktop or a shelf Alternatively it can be wall mounted using the mounting kit and guidelines supplied with the unit BreezeMAX PRO 5000 CPE Product Manual Chapter 2 Installation Installing the IDU 1D Indoor Unit of the PRO 5000 CPE 2 2 3 CPE IDU 1D Connectors and LEDs ALT ATEIKIAKA ITI RESET Figure 2 7 CPE IDU 1D Front Panel Figure 2 8 CPE IDU 1D 3D View Table 2 4 CPE IDU 1D Connectors Name Connector Functionality ETHERNET 4 10 100Base T RJ 45 with 2 Connection to the user s LAN PC on the side panel embedded LEDs Cable connection to a hub switch router Crossed Cable connection to a PC Straight RADIO 10 100Base T RJ 45 Connection to the ODU on the front panel BreezeMAX PRO 5000 CPE Product Manual Chapter 2 Installation Installing the IDU 1D Indoor Unit of the PRO 5000 CPE Table 2 4 CPE IDU 1D Connectors Name Connector Functionality POWER 3 pin AC Mains power connection on the bottom panel Table 2 5 CPE IDU 1D LEDs Name Description Functionality POWER 3 Power Indic
46. eezeMAX PRO 5000 CPE Product Manual Chapter 2 Installation Installing the ODU of the PRO CPE 2 1 5 Connectors IDU COM SAU Port Figure 2 4 Bottom Panel of the ODU without sealing covers Table 2 2 CPE ODU PRO Connectors Name Connector Functionality IDU COM 10 100Base T RJ 45 Connection to the IDU SAU Special mini USB Connection to SAU 2 1 6 Connecting the Cables 2 1 6 1 Connecting the Grounding Cable The Grounding screw marked is located on the back panel of the ODU see Figure 2 1 gt To connect the grounding cable 1 Connect one end of a grounding cable to the grounding screw and tighten the grounding screw firmly 2 Connect the other end of the grounding cable to a good ground earth connection BreezeMAX PRO 5000 CPE Product Manual Chapter 2 Installation Installing the ODU of the PRO CPE 2 1 6 2 A Connecting the IDU ODU Cable CAUTION Use only Category 5E 4x2x24 FTP outdoor cables from an approved manufacturer See list of approved cables in Table 2 1 The length of the Indoor to Outdoor cable should not exceed 90 meters The length of the Indoor to Outdoor cable together with the length of the Ethernet cable connecting the CPE IDU 1D to the data equipment should not exceed 100 meters To prepare the IDU ODU cable Use a crimp tool for RJ 45 connectors to prepare the wires Insert them into the appropriate pins and use the tool to crimp the conne
47. eters M Best BST AU Parameters and Best BST AU Table Configured Best BS ID the configured Preferred BST AU ID Together with The BS ID comprises 6 octets of up to 3 digits each where the range of each group is 0 to 255 The default BS ID is 0 0 0 0 0 0 BreezeMAX PRO 5000 CPE e Product Manual Chapter 4 Operation BST AU Parameters Current Best BS ID Selected Best BS ID Preferred Best BS ID Current Preferred BS ID M Selected BST AU Parameters Selected BST AU ID The BST AU ID to which the CPE is currently connected Selected Rx Frequency The Rx Frequency of the BTS to which the CPE is currently connected Selected Best BS RSSI The Rx RSSI of the BTS to which the CPE is currently connected Selected Best BS SNR dB The Rx SNR of the BTS to which the CPE is currently connected Selected BW The bandwidth of the BTS to which the CPE is currently connected M Best BST AU Table displays the following details for each of the BS s found during the scanning process BS ID Rx Frequency KHz SNR dB RSSI dBm Bandwidth E BST AU and Preferred BST AU Parameters BST AU ID BST AU ID Mask Preferred BST AU ID BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation BST AU Parameters Preferred BST AU ID Mask Mobility Mode enables defining the expected mobility of the SU Nomadic or Mobile The default is Nomadic After config
48. etworks can be made up of interconnected smaller networks spread throughout a building a state or the entire globe Wireless Communications Services The variety of services available using frequencies in the 2 3 GHz band for general fixed wireless use Waste Electronic and Electrical Equipment The purpose of Directive 2002 96 EC on waste electrical and electronic equipment WEEE is as a first priority the prevention of waste electrical and electronic equipment WEEE and in addition the reuse recycling and other forms of recovery of such wastes so as to reduce the disposal of waste It also seeks to improve the environmental performance of all operators involved in the life cycle of electrical and electronic equipment e g producers distributors and consumers and in particular those operators directly involved in the treatment of waste electrical and electronic equipment Wireless LAN The name commonly given to the IEEE 802 16 standard Specifications for fixed broadband wireless metropolitan access networks MANSs that use a point to multipoint architecture WIMAX supports very high bit rates in both uploading to and downloading from a base station up to a distance of 30 miles Product Manual
49. gegen S i Your Open WiMAX Choice BreezeMAX PRO 5000 CPE Product Manual Software Version 4 6 July 2009 P N 215315 Document History Document History First Release New Product Manual SW Version 4 6 July 2009 BreezeMAX PRO 5000 CPE Product Manual Legal Rights Legal Rights Copyright 2009 Alvarion Ltd All rights reserved The material contained herein is proprietary privileged and confidential and owned by Alvarion or its third party licensors No disclosure thereof shall be made to third parties without the express written permission of Alvarion Ltd Alvarion Ltd reserves the right to alter the equipment specifications and descriptions in this publication without prior notice No part of this publication shall be deemed to be part of any contract or warranty unless specifically incorporated by reference into such contract or warranty Trade Names Alvarion BreezeCOM WALKair WALKnet BreezeNET BreezeACCESS BreezeLINK BreezeMAX BreezeLITE BreezePHONE 4Motion BreezeCONFIG MGW eMGW and or other products and or services referenced here in are either registered trademarks trademarks or service marks of Alvarion Ltd AIl other names are or may be the trademarks of their respective owners WiMAX Forum is a registered trademark of the WiMAX Forum WiMAX the WiMAX Forum logo WiMAX Forum Certified and the WiMAX Forum Certif
50. haracters installer No case sensitive Local TFTP Server IP Address IP address 192 168 254 250 Yes Configuration Upload File Name Configuration Download File Name Choose Upload Download E Upload Upload No Action E Download TM amp PM Files SW File Name Yes Ethernet Port Auto Negotiation II Disable Enable No Enable Disable E Enable Ethernet Port Speed and E 10Mbps Half Duplex No Duplex E 10Mbps Full Duplex MI 100Mbps Half Duplex E 100Mbps Full Duplex Registration Parameters User Name 1 to 32 printable characters lt MAC_Address gt WiMa No case sensitive x com Password 1 to 32 printable characters No case sensitive Organization Up to 32 printable characters No Address Up to 32 printable characters Yes Country Up to 12 printable characters Yes BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation Table 4 3 SU Parameters Summary Parameters Summary Parameter Range Default Run Time Updated Authentication E Not Authenticated EAP TTLS Yes E EAPTTLS E EAP TLS BS ID Parameters BST AU ID 6 octets of up to 3 digits each 0 0 0 0 0 0 Yes Each group range is 0 255 BST AU ID Mask 6 octets of up to 3 digits each 0 0 0 0 0 0 Yes Each group range is 0 255 Preferred BST AU ID 6 octets of up to 3 digits each 0 0 0 0 0 0 Yes Each group range is 0 255 Preferred BS ID Mask 6 octets of up to 3 digits each 0 0 0 0 0 0 Yes Each group range is 0 255
51. hieved using a reflected signal In this case the antenna is not necessarily directed toward the BTS 6 Secure the ODU firmly to the pole BreezeMAX PRO 5000 CPE Product Manual Chapter 3 Commissioning Operation Verification 3 4 Operation Verification To verify proper operation of the PRO CPE examine the LED indicators on the IDU see Table 2 5 and the SAU see Table 3 2 Ed NOTE Verifying the correct operation of the ODU using the SAU LEDs is meaningful only after the configuration and alignment processes are completed and the unit is synchronized with a BS To verify proper connection to the end user s data equipment examine the Ethernet Integrity and Ethernet Activity LEDs of the Ethernet connectors To verify data connectivity from the end user s PC or from a portable PC connected to the unit ping a known device in the network or connect to the Internet BreezeMAX PRO 5000 CPE Product Manual 4 Chapter Operation Chapter 4 Operation In This Chapter Introduction to SU Management on page 42 Accessing the Web Configuration Server on page 43 Using the Web Configuration Server on page 44 Show All on page 45 Unit Control Parameters on page 46 Registration Parameters on page 57 BST AU Parameters on page 61 Radio Parameters on page 65 ATPC Parameters on page 70 Performance Monitor on page 73 Service Parameter
52. ied logo are trademarks of the WiMAX Forum Statement of Conditions The information contained in this manual is subject to change without notice Alvarion Ltd shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this manual or equipment supplied with it Warranties and Disclaimers All Alvarion Ltd Alvarion products purchased from Alvarion or through any of Alvarion s authorized resellers are subject to the following warranty and product liability terms and conditions Exclusive Warranty a Alvarion warrants that the Product hardware it supplies and the tangible media on which any software is installed under normal use and conditions will be free from significant defects in materials and workmanship for a period of fourteen 14 months from the date of shipment of a given Product to Purchaser the Warranty Period Alvarion will at its sole option and as Purchaser s sole BreezeMAX PRO 5000 CPE Product Manual Legal Rights remedy repair or replace any defective Product in accordance with Alvarion standard R amp R procedure b With respect to the Firmware Alvarion warrants the correct functionality according to the attached documentation for a period of fourteen 14 month from invoice date the Warranty Period During the Warranty Period Alvarion may release to its Customers firmware updates which include additio
53. ifiers VLAN DSCP of packets processed by the units For each service rule the following parameters are displayed Service ID up to 8 non overlapping Service Rules can be defined via the BTS VLAN ID Configured from 0 to 4095 VLAN Priority Configured from 0 to 7 DSCP Configured from 0 to 63 DSCP Marking Enabled Disable When enabled the DSCP value of a packet arriving from the Ethernet port must be 0 otherwise it will be discarded Before forwarding to the wireless port the 0 DSCP value will be replaced by the defined DSCP value and the VLAN tag will be removed For packets with this DSCP value arriving from BreezeMAX PRO 5000 CPE Ed Product Manual Chapter 4 Operation Service Parameters the wireless port the defined VLAN tag will be added before forwarding it to the Ethernet port without changing the DSCP value If DSCP Marking is disabled a packet with the defined VLAN tag VLAN ID and Priority will be forwarded to the wireless port after removal of the VLAN tag The DSCP value of these packets is the DSCP configured the packet will be forwarded regardless of its DSCP value For packets with the configured DSCP value arriving from the wireless port the defined VLAN tag VLAN ID and Priority will be added before forwarding to the Ethernet port NOTE Ed In the current version the Service Definition table is empty For additional information on service configuration refer to the System Manual
54. k PC with a web browser It also enables downloading of SW files control of the running SW version and downloading uploading of the configuration file enabling simplified and faster configuration process The Web Configuration Server also provides a selection of performance monitoring capabilities allowing installers and technicians to view information on link quality and traffic counters These monitoring capabilities enable performance verification and problems identification To further support local testing the program also enables temporary control of the ATPC mechanism BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation Accessing the Web Configuration Server 4 2 Accessing the Web Configuration Server To configure parameters using the Web Configuration Server connect a PC Notebook with a web browser to the Ethernet port of the IDU using a straight Ethernet cable 1 Configure the PC s IP parameters to enable connectivity with the unit The IP address of the SU for local management access is 192 168 254 251 The Subnet Mask is 255 255 255 0 The recommended IP address for the PC is 192 168 254 250 as this is also the default TFTP Sever IP Address required for downloading SW versions and for downloading uploading configuration files 2 Open a web browser and connect to http 192 168 254 251 The Enter Network Password window is displayed Enter the Username and password and click OK Ed NOTE The default pa
55. meters Shadow SW Version Running from Main or Shadow E Upload Download Parameters Local TFTP Server IP address the IP address of the TFTP server from the LAN side used for SW File Configuration File download Remote TFTP Server IP address the IP address of the TFTP server from the WAN side used for SW File Configuration File download SW File Name the name in the TFTP server of the SW version to be downloaded to the unit Configuration File Upload Name the name of the configuration file to be uploaded Configuration File Download Name the name of the configuration file to be downloaded List of TM amp PM Files gathered the Traffic Monitoring TM and Performance Monitoring PM files detected by the unit 4 5 2 Reset Unit Reset Unit Reset Device Reset Unit Figure 4 2 Reset Unit Page The Reset Unit page enables to reset the unit Click Reset Unit To avoid unintentional reset you will be prompted to confirm the reset request Changes to most of the configurable parameters are applied only after reset Refer to Section 4 14 for information on which parameters are changeable in run time and which changes are applied only after reset BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation Unit Control Parameters 4 5 3 Change Password Change Password Figure 4 3 Change Password Page The Change Password page enables to change the login password Enter the old password
56. mp and threaded rods x NOTE There is a groove on one end of the threaded rod Insert the rods with the grooves pointing outward and fasten them to the unit using a screwdriver Install the unit with the bottom panel which includes the connectors facing downward Ed NOTE You can install the ODU with the arrow on the back of the unit facing upwards or rightwards Make sure that the connectors are facing downwards BreezeMAX PRO 5000 CPE Product Manual Chapter 2 Installation Installing the ODU of the PRO CPE Grounding screw Figure 2 1 ODU Pole Installation Using the Special Clamp Arrow Facing Upwards BreezeMAX PRO 5000 CPE Product Manual Chapter 2 Installation Installing the ODU of the PRO CPE Figure 2 2 ODU Pole Installation Using the Special Clamp Arrow Facing Rightwards BreezeMAX PRO 5000 CPE Product Manual Chapter 2 Installation Installing the ODU of the PRO CPE 2 1 4 2 Pole Mounting the ODU with the Tilt Accessory Tilt Control Screw Figure 2 3 ODU Pole Installation Using the Tilt Accessory Vertical Polarization gt To mount the ODU on a pole using the Tilt accessory 1 Attach the Tilt accessory to the ODU using the two pairs of flat washers spring washers and nuts supplied in the Tilt kit 2 Mount the Tilt accessory on a 1 to 4 pole using two 9 16 metal bands 3 Release slightly the Tilt Control Screw tilt the ODU downward upward as required and re tighten the screw Br
57. nal performance improvements and or bug fixes upon availability the Warranty Bug fixes temporary patches and or workarounds may be supplied as Firmware updates Additional hardware if required to install or use Firmware updates must be purchased by the Customer Alvarion will be obligated to support solely the two 2 most recent Software major releases ALVARION SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY PURCHASER S OR ANY THIRD PERSON S MISUSE NEGLIGENCE IMPROPER INSTALLATION OR IMPROPER TESTING UNAUTHORIZED ATTEMPTS TO REPAIR OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCIDENT FIRE LIGHTNING OR OTHER HAZARD Disclaimer a The Software is sold on an AS IS basis Alvarion its affiliates or its licensors MAKE NO WARRANTIES WHATSOEVER WHETHER EXPRESS OR IMPLIED WITH RESPECT TO THE SOFTWARE AND THE ACCOMPANYING DOCUMENTATION ALVARION SPECIFICALLY DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND NON INFRINGEMENT WITH RESPECT TO THE SOFTWARE UNITS OF PRODUCT INCLUDING ALL THE SOFTWARE DELIVERED TO PURCHASER HEREUNDER ARE NOT FAULT TOLERANT AND ARE NOT DESIGNED MANUFACTURED OR INTENDED FOR USE OR RESALE IN APPLICATIONS WHERE THE FAILURE MALFUNCTION OR INACCURACY OF PRODUCTS CARRIES A RISK OF DEATH OR BODILY INJURY OR SEVERE PHYSICAL OR ENVIRONMENTAL
58. ng BreezeMAX PRO 5000 CPE on page 4 E Specifications on page 5 BreezeMAX PRO 5000 CPE O Product Manual Chapter 1 Products Description BreezeMAX CPEs 1 1 BreezeMAX CPEs The WiMAX compatible BreezeMAX PRO 5000 CPE Subscriber Units SUs are powered by Sequans chipset BreezeMAX PRO 5000 CPE is currently available in the 5 GHz frequency band The units support the TR 069 CPE WAN Management Protocol CWMP allowing efficient management by an Auto Configuration Server ACS In addition configuration and performance monitoring of a single unit can be performed using the following options E Using a PC Notebook with an HTTP browser to access the built in web configuration server E Using TFTP to upload download a Configuration File BreezeMAX PRO 5000 CPE Product Manual Chapter 1 Products Description Introducing BreezeMAX PRO 5000 CPE 1 2 Introducing BreezeMAX PRO 5000 CPE The PRO CPE comprises an Outdoor Unit ODU and an Indoor Unit IDU The ODU includes the modem radio data processing and management components of the SU It also includes an integral high gain flat antenna The ODU connects to the IDU and to the user s equipment through a 10 100BaseT Ethernet port The indoor unit is powered from the mains and connects to the ODU via a Category 5E Ethernet cable carrying the Ethernet data between the two units as well as power 54 VDC and control signals to the ODU and status indications from
59. nning version will be defined as Main and will be used each time the unit reboots The previous version is defined now as Shadow BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation Unit Control Parameters The SU functions as a TFTP client enabling the loading of SW files from a TFTP server The SW Versions Control submenu includes the following fields E Main SW File Name the name of the Main software file E Main SW Version the version of the Main software E Shadow SW File Name the name of the software file in the shadow E Shadow SW Version the version of the software in the shadow E Running From indicates whether the unit is currently running the Main or the Shadow version M Local TFTP Server IP address the IP address of the TFTP server from the LAN side used for SW version download The default TFTP Server IP address is 192 168 254 250 You can enter a new TFTP Server IP address x NOTE The same TFTP Server IP Address parameter is used in the SW Download Configuration File Download and Configuration File Upload processes M Remote TFTP Server IP address the IP address of the WAN TFTP server used for SW version download E SW File Name the name in the TFTP server of the SW version file to be downloaded to the unit The SW Versions Control submenu includes the following control buttons E SW Download click to execute the SW download operation To avoid unintentional actions you will be prompted to
60. no 86 BreezeMAX PRO 5000 CPE Product Manual Figures Figure 2 1 Figure 2 2 Figure 2 3 Figure 2 4 Figure 2 5 Figure 2 6 Figure 2 7 Figure 2 8 Figure 3 1 Figure 3 2 Figure 4 1 Figure 4 2 Figure 4 3 Figure 4 4 Figure 4 5 Figure 4 6 Figure 4 7 Figure 4 8 Figure 4 9 Figure 4 10 Figure 4 11 Figure 4 12 Figure 4 13 Figure 4 14 Figure 4 15 Figure 4 16 Figure 4 17 BreezeMAX PRO 5000 CPE Figures ODU Pole Installation Using the Special Clamp Arrow Facing Upwards 17 ODU Pole Installation Using the Special Clamp Arrow Facing Rightwards 18 ODU Pole Installation Using the Tilt Accessory Vertical Polarization 19 Bottom Panel of the ODU without Sealing COVErs i 20 Ethernet Connector Pin Assignmenis iii ichoeseeioonecenseecentaens 22 Inserting the IDU COM Cable into the Sealing Cap 23 SEET eege eege ees 25 CPEADU 1D BD Vi SW illa 25 Legionari 34 Re RE E A E ETA 95 Web Configuration Server Main Wumdow ii 43 Reset Unit Pagella ai 48 Change Password Page sssoeeeesssseeeseenreserrrsstrrnnretrnrrrttnrnserernneernnnernnnnese ertene 49 SW Versions Control e lia alati 50 Configuration Control Patella 52 TM amp PM File Upload Control Page 55 Ethernet Operation Mode Page 55 Registration Show Page ira 57 Registr tion Pagelle roland 58 BSTAU Paleari 62 PGND Ree 65 Frequency Scanning Palese 67
61. nt Distribution Service MMDS is a licensed wireless service that has the capability to provide broadband access MMDS operates in several parts of the 2 GHz spectrum Microsoft Challenge Handshake Authentication Protocol an implementation of the CHAP protocol that Microsoft created to authenticate remote Windows workstations In most respects MS CHAP is identical to CHAP but there are a few differences MS CHAP is based on the encryption and hashing algorithms used by Windows networks and the MS CHAP response to a challenge is in a format optimized for compatibility with Windows operating systems Maximum Segment Size Not Available or Not Applicable Network Entry Network Interface Card An expansion board you insert into a computer or a built in component that enables the computer to connect to a network Most NICs are designed for a particular type of network protocol and media although some can serve multiple networks Outdoor Unit Orthogonal Frequency Division Multiplexing A method for multiplexing signals which divides the available bandwidth into a series of frequencies known as tones Orthogonal tones do not interfere with each other when the peak of one tone corresponds with the null The rapid switching frequency hopping technique is intended to allow more robust data service Orthogonal Frequency Division Multiple Access It s a logical extension of OFDM anda modulation multiple access technique OFDMA divides a sign
62. ntegrated antenna is supported and therefore selection is not available BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation ATPC Parameters 4 9 4 9 1 ATPC Parameters In regular operation the level of the signal transmitted by the SU is controlled by the Adaptive Transmission Power Control ATPC mechanism of the serving BS The ATPC page enable temporary control of the signal transmitted by the SU It is intended for test purposes only These settings will not be saved and will automatically return to original values as received from the BS when the unit resets or upon closing the web interface The ATPC menu includes the following sub menus E Show E ATPC Show Select this option to view the current Multirate and ATPC parameters M Last Tx Rate the last detected transmission rate E Optimal Rx Rate the transmission rate best suited to the connection E ATPC The current status Enabled Disabled of the ATPC mechanism E Tx Power the transmission power level Show All parameters ATPC Last Tx Rate qpsk cc 1 2 Optimal Rx Rate qpsk cc 1 2 ATPC Enable Tx Power D Figure 4 14 ATPC Show Page BreezeMAX PRO 5000 CPE O Product Manual Chapter 4 Operation ATPC Parameters 4 9 2 ATPC Multi rate and ATPC Parameters 5 xGHz Disable Enable pr Universal 3 Universal range 4900000 5950000 Max Power 21dBm 64QAM 18dBm Figure 4 15 ATPC Page From the ATPC page you can ena
63. nter mode with Cipher block chaining Message authentication code Counter mode with Cipher block chaining Message authentication code CCM is an encryption protocol in the 802 11i standard The CCM protocol CCMP is based upon the CCM mode of the AES encryption algorithm and utilizes 128 bit keys Automatic Platform Detection A mechanism that dtects the wireless link protocol used by the Base Station enabling automatic selection of the operation mode to be used Subscriber Unit Address Resolution Protocol Internet protocol used to map an IP address to a MAC address Defined in RFC 826 Automatic Transmit Power Control Additive white Gaussian noise also known as white noise contains equal energy per frequency across the spectrum of the noise employed Binary Phase Shift Keying A data transfer technique BPSK transmits data using two phase modulation signals one phase representing a binary one and the other representing a binary zero The signal is divided into bits their status is determined by the preceding wave If the wave changes for example the signal is reversed Base Station The WiMAX BS is an entity that implements the WiMAX MAC and PHY in compliance with the IEEE 802 16e standard A BS operates on one frequency assignment and incorporates scheduler functions for uplink and downlink resources Base Transceiver Station A wireless network element that provides the radio interface of the network The BTS comprises the ra
64. o confirm the request E Refresh select this option to clear the fields 4 5 5 Configuration Control Configuration Control Configuration Upload File Name SU UPLOAD CFG Configuration Download File Name SU_DOWNLOAD_CFG Local TFTP Server IP Address fis be Pa Pen Remote TFTP Server IP Address 192 168 254 250 Choose upload download Action Upload Download Perform Action Refresh Set Factory Defaults Figure 4 5 Configuration Control Page BreezeMAX PRO 5000 CPE 6 Product Manual Chapter 4 Operation Unit Control Parameters The Configuration Control Submenu enables to define parameters related to uploading downloading of configuration files to from the SU and to initiate the upload download operation The Configuration Control page includes the following fields E Configuration Upload File Name enter the name in the TFTP server directory of the configuration file to be uploaded A Configuration File Upload Name consists of up to 50 characters The default Configuration File Upload Name is SU_UPLOAD_CFG E Configuration Download File Name enter the name in the TFTP server of the required configuration file A Configuration File Download Name consists of up to 50 characters The default Configuration File Download Name is SU_DOWNLOAD_CFG M Local TFTP Server IP Address enter the IP address of the LAN TFTP server The default TFTP Server IP address is 192 168 254 250 x NOTE The same TFTP Server IP Address p
65. off Unit failur Try replacing the IDU If the problem persists try replacing the IDU ODU cable If the problem persists try replacing the ODU BreezeMAX PRO 5000 CPE Product Manual Appendix A Troubleshooting PRO CPE Troubleshooting Problem and Indication Possible Cause Corrective Action The Ethernet Activity and or Integrity LEDs are on but no management access using Telnet or web browser and the unit does not respond to ping Wrong IP configuration Make sure that the PC is on the same subnet as the unit The unit s IP address for management purposes is 192 168 254 251 and the subnet mask is 255 255 255 0 Wrong Ethernet port operation mode Make sure that the speed and duplex settings in the PC match the configuration in the unit The default operation mode is Auto Negotiation and supported speeds are 10 100 Mbps Full or Half Duplex ARP table in the PC contains a wrong MAC address for the 192 168 254 251 IP address due to a recent connection to another SU Perform arpV d at the DOS command prompt to clear the ARP table and retry the Telnet command to the unit Bridging table in SU is full expected when Number of Supported Devices configurable from the Base station s side is set to a small number Reset the SU to clear the table and retry the Telnet command to the unit Scanning failed and or Base Station not found None of the LINK QUALITY L
66. quency N Main Step 125 KHz Start Frequency N Main Step 500 KHz N 1 2 End Frequency is the upper limit for the scanned frequencies In addition the Discrete Frequencies option enables defining up to 10 discrete frequencies to be used in the scanning process in addition to the frequencies defined by the Frequency Scanning parameters BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation Radio Parameters Frequency Scanning Parameters N Bo Start freq scan IM B1 125KHz T B2 250KHz T B3 375KHz T B4 500KHz T B5 625KHz I B6 750KHz I B7 1250KHz Auto e Na zl Delete select Discrete Scanning Frequencies Scanning Table Full Scanning table list 5400000 10MHz Auto 5402500 10MHz Auto 5405000 10MHz Auto 5407500 10MHz Auto 5947500 10MHz Auto 5950000 10MHz Auto Best BS Scanning table list Figure 4 12 Frequency Scanning Page The Frequency Scanning menu includes the following fields E Scanning Table displays the list of all current frequencies that participate in the full scanning process Following the Full Scanning Table the Best BS Scanning Table displays all the frequencies associated with BSs that are included in the current Best BS Table BreezeMAX PRO 5000 CPE Q Product Manual Chapter 4 Operation Radio Parameters E Start Rx Frequency KHz the lowest frequency in the range of frequencies to be scanned in KHz The available values depend on the radio band of
67. rence into such contract or warranty The information contained herein is merely descriptive in nature and does not constitute an offer for the sale of the product described herein Any changes or modifications of equipment including opening of the equipment not expressly approved by Alvarion Ltd will void equipment warranty and any repair thereafter shall be charged for It could also void the user s authority to operate the equipment BreezeMAX PRO 5000 CPE Product Manual About This Manual About This Manual This document describes and explains how to install and manage the BreezeMAX PRO 5000 CPE units using SW Version 4 6 This document contains the following chapters E Chapter 1 Product description Describes the PRO 5000 CPE and its specifications E Chapter 2 Installation Describes how to install the PRO 5000 CPE E Chapter 3 Commissioning Describes how to configure basic parameters align the antenna and validate unit operation E Chapter 4 Operation and Administration Describes how to use the web interface application for configuring parameters checking system status and monitoring performance E Appendix A Provides troubleshooting guidelines for CPE E Glossary A listing of commonly used terms BreezeMAX PRO 5000 CPE o Product Manual Contents Chapter EE get Ce LN 1 1 1 BreezeMAXCPES _ lla 3 1 2 Introducing BreezeMAX PRO 5000 CPE ecnrriiiiiiiin
68. rnet downtime after which it will be up again The range is from 3 seconds up to 100 seconds M Click Apply to save the changes BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation Registration Parameters 4 6 4 6 1 Registration Parameters The Registration menu includes the following sub menus E Show E Registration Show Select this submenu to view the registration parameters excluding the User Password that is not shown for security reasons Show All parameters Registration parameters CPEMACaddress WiMax com CPEMACaddress WiMax com EAP TTLS Not Operational Figure 4 8 Registration Show Page E User Name Configured and Actual the name of the unit to be used for service provisioning Changes to the User Name parameter are applied only after reset Therefore the actual value may differ from the configured value Both the actual and configured values are displayed E Organization E Address E Country E Authentication the method of authentication being used to secure the WiMAX connection E Authentication Actual the status of the authentication BreezeMAX PRO 5000 CPE Q Product Manual Chapter 4 Operation Registration Parameters Rejected the CPE s authentication request was rejected Authenticated the CPE is connected to the BTS Not Operational no BTS is found 4 6 2 Registration User Registration CPEMACaddress Wilta
69. rrier If no carrier is sensed for a specific period of time a device can transmit If two devices transmit at once a collision occurs and is detected by all colliding devices This collision subsequently delays retransmissions from those devices for some random length of time Ethernet and IEEE 802 3 use CSMA CD access Continuous Wave An unmodulated RF signal CPE WAN Management Protocol See also TR 069 Dynamic Host Configuration Protocol A protocol for dynamically assigning IP addresses from a pre defined list to nodes on a network Using DHCP to manage IP addresses simplifies client configuration and efficiently utilizes IP addresses Down Link Differentiated Service Code Point AKA DiffServ An alternate use for the ToS byte in IP packets Six bits of this byte are being reallocated for use as the DSCP field where each DSCP specifies a particular per hop behavior that is applied to the packet Extensible Authentication Protocol A protocol used between a user station and an authenticator or authentication server It acts as a transport for authentication methods or types It in turn may be encapsulated in other protocols such as 802 1x and RADIUS EAP is defined by RFC 2284 Extensible Authentication Protocol Tunneled Transport Layer Service A type of mutual authentication protocol where just the server sends a digital certificate to identify itself to the clients Electro Magnetic Compatibility The capability of equipment or
70. rver configure the TFTP Server IP address to the same address Enter the name of the configuration file as called in the TFTP server as the Configuration File Download Name Select Download in the Choose Upload Download Action field Click Perform Action To avoid unintentional actions you will be prompted to confirm the request Confirm the download request and wait to receive a success failure message Following a successful download reset the unit to apply the new configuration The Configuration Control page includes the following control buttons Perform Action executes the upload download action Refresh clears the screen Set Factory Defaults click to reset the unit and revert to the default configuration To avoid unintentional actions you will be prompted to confirm the request All parameters except the Password will revert to the factory default values TM PM Files Control Traffic and performance monitoring allow for a variety of statistical data to be collected about the CPE and its WiMAX link The TM Traffic Monitoring amp PM Performance Monitoring Files Control page enables the user to define parameters related to uploading of TM amp PM files where link quality data is stored to the TFTP server directory and to initiate the upload operation BreezeMAX PRO 5000 CPE 9 Product Manual Chapter 4 Operation Unit Control Parameters TM amp PM File Upload Control 001122334455 _01_01_1970_06 46
71. ry where the unit is located This parameter is optional and is intended for optional use by the Network management System The Country name can include up to 12 printable characters E Authentication A security supplicant incorporated into the device supports Single EAP TTLSv0 with MSCHAPv2 method according to RFC2759 The Authentication Mode allows enabling disabling authentication using the security supplicant The available options are Not Authenticated EAP TTLS EAP TLS When EAP TTLS EAP TLS is configured the CPE will use the configured User Name Password with EAP TTLS EAP TLS protocol for CPE Authentication by AAA Over the air data is encrypted using AES CCM128 as defined in IEEE 802 16 2005 When Not Authenticated the CPE will not execute the EAP TTLS EAP TLS protocol and will be associated to the ASN GW in non authenticated mode Over the air data will not be encrypted If the SBC negotiation shows that the connected BS is working in Not Authenticated mode the CPE will change automatically to Not Authenticated mode and will complete the network entry without EAP TTLS EAP TLS authentication process BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation Registration Parameters The default is EAP TTLS BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation BST AU Parameters 4 7 BST AU Parameters The quest for load sharing together with the desire to create best throughput condition
72. s on page 77 Management Parameters on page 79 Logout on page 80 Parameters Summary on page 81 BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation Introduction to SU Management 4 1 Introduction to SU Management The units support the TR 069 CPE WAN Management Protocol CWMP allowing efficient management by an Auto Configuration Server ACS In addition configuration and performance monitoring of a single unit can be performed either locally via the Ethernet port or remotely using any of the following options E Using a PC Notebook with an http browser to access the built in web configuration server E Using TFTP to upload download a Configuration File For local management the management IP address is 192 168 254 251 with subnet mask 255 255 255 0 Remote over the air management is done using a WAN management IP address acquired from a DHCP server as a part of the Network Entry process The DHCP server should supply also the IP address of the ACS management station Remote management service is always in IP CS service mode even if the unit uses Ethernet CS for regular services In the uplink the DSCP value of management packets sent by the unit can be configured only by the remote management system using TR 069 the default is 6 In downlink management packets the DSCP value is ignored The Web Configuration Server enables the configuration of all SU parameters using a Noteboo
73. s for the SU created the need for the Best BS feature to enable an SU to connect to the best BS in its neighborhood The SU scans a set of frequencies see Radio Parameters on page 65 searching for BSs it can communicate with Each BS in the network is configured with a unique BS ID The BS ID parameters in the SU define a set of BS IDs and the SU is allowed to communicate only with BSs whose BS ID is included in the BS IDs range defined by the applicable parameters Each of the BSs with which the SU can communicate perform initial phase of network entry is given a quality mark based on the quality of the signal at which it is received by the SU At the end of the scanning period the SU reaches a Best BS decision according to the information gathered The BS with the highest quality mark is selected as the Best BS and the SU will immediately try to associate with it at the relevant frequency bandwidth The range used for scanning is defined by the BS ID and BS ID Mask parameters The initial range can be limited by defining a preferred range of BSs and selecting the best BS in the preferred range If no device is found in the preferred range the SU will scan the entire range A Mobility Mode parameter enables supporting optimal performance after loosing connectivity to the BS according to the expected mobility of the SU A Mobile SU is expected to move among different BSs while a Nomadic SU is typically stationary although it may al
74. so be moved to the coverage area of a different BS If a Nomadic SU loses communication with the selected BS it will continue searching for it for 5 minutes If not found within 5 minutes the SU initiates a short scan and will try to associate with the second BS in the of Best BS Table and so on checking all the BSs in the table and trying to associate with the best one If no BS from the table is found the Best BSs table will be cleared and the SU will initiate a Full Scan all defined scanning frequencies bandwidths and all BSs in the defined range The same process will be executed also for a Mobile SU with one exception The SU will search for the BS to which it was previously connected only for 100 milliseconds to allow faster association with a new BS The same process will be executed following a reset of the SU with the exception that the SU will search for the BS to which it was previously connected for one minute only BreezeMAX PRO 5000 CPE Q Product Manual Chapter 4 Operation BST AU Parameters Best BST AU Parameters and Best BST AU Table 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 12 197 1 0 0 0 0 0 0 0 0 0 0 0 0 Selected BST AU Parameters Selected BST AUID 0 0 2 12 197 1 sdeted net SASSI Di seg ES Best BST AU Table 0 0 2 12 197 1 5475000 27 16 74 45 BST AU and Preferred BST AU Parameters Se eme Nomadic Mobile 8 Figure 4 10 BST AU Page The BST AU page includes the following param
75. squeeze the seal Carefully insert the cable through the groove 4 Insert the cable through the housing and insert the seal at the back end of the housing 5 Tighten the sealing nut onto the housing 6 Stricken the gasket on the front end of the housing Sealing nut Seal Housing Gasket x Figure 2 6 Inserting the IDU COM Cable into the Sealing Cap 7 Connect the Ethernet cable to the IDU COM RJ 45 connector and tighten the sealing cap 8 Route the cable to the location selected for the indoor equipment 9 Assemble an RJ 45 connector with a protective cover on the indoor end of the IDU ODU cable Refer to the pin assignment and color codes in standard cables described above BreezeMAX PRO 5000 CPE Product Manual Chapter 2 Installation Installing the IDU 1D Indoor Unit of the PRO 5000 CPE did VISA I S ll 2 2 1 2 x fe de Installing the IDU 1D Indoor Unit of the PRO 5000 CPE Installation Requirements Packing List E BMAX CPE IDU 1D E Wall mounting kit Additional Installation Requirements E Ethernet cable s a crossed cable if connecting to a hub switch and a straight cable if connecting directly to a PC Network Interface Card NIC NOTE The length of the Ethernet cable connecting CPE IDU 1D to the user s equipment together with the length of the IDU ODU cable should not exceed 100 meters E Mains power cord E Mains plug adapter or termination plug if the power plug on the suppli
76. ssword is installer 3 The Main window of the Web Configuration Server is displayed enabling access to the required parameters configuration and performance monitoring options Show All Unit Control Registration BST AU Radio ATPC Performance Monitor Service Management Logout Welcome to the SU Web Configuration Server Please use menu bar to configure or get infomation from device Figure 4 1 Web Configuration Server Main Window BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation Using the Web Configuration Server 4 3 Using the Web Configuration Server The Web Configuration Server view when using a Notebook PC consists of a number of menu links to the left Clicking on each of them will display the configuration status page for the selected menu item with the applicable content configurable parameters options or status information in the main area Several pages include a page selection bar at the top of the page enabling selection between several pages related to the same menu item Several pages include a Current Parameters area and a Configured Parameters area The Current Parameters area displays the current unit s settings To change the settings of the parameters enter the new settings in the configuration field and click the Update Apply button The change will appear in the Configured Parameters area and will take effect after performing reset to the unit The Web Configura
77. systems to be used in their intended environment within designed efficiency levels without causing or receiving degradation due to unintentional EMI Electro Magnetic Interference EMC generally encompasses all of the electromagnetic disciplines European Telecommunications Standards Institute A non profit organization producing voluntary telecommunications standards used throughout Europe some of which have been adopted by the EC as the technical base for Directives or Regulations Federal Communications Commission A U S government agency that supervises licenses and controls electronic and electromagnetic transmission standards Forward Error Correction A method of communicating data that can correct errors in transmission on the receiving end Prior to transmission the data is put through a predetermined algorithm that adds extra bits specifically for error correction to any character or code block If the transmission is received in error the correction bits are used to check and repair the data Product Manual Glossary FFT FIPS FTP GUI HTTP IDU IEEE IEEE 802 3 IEEE 802 16 IEEE 802 16e LAN LED MAC Address BreezeMAX PRO 5000 CPE Fast Fourier Transform An algorithm for converting data from the time domain to the frequency domain often used in signal processing Federal Information Processing Standards The Federal Information Processing Standard FIPS Publication 140 2 1 called Security
78. the ODU A miniature SU Alignment Unit SAU that includes signal strength and status indicators is also available to support easy and convenient antenna alignment and status verification BreezeMAX PRO 5000 CPE Product Manual Chapter 1 Products Description LS Specifications Specifications 1 3 1 Radio Table 1 1 Radio Specifications Item Deiails Frequency Band Frequencies MHz 5 GHz 4900 5950 Operation Mode E TDD Half Duplex Resolution Channel Bandwidth E 5MHZ E 10 MHz Central Frequency 0 125 MHz 5 GHz Integral Antenna Embedded dual polorization antennas 17dBi 24 AZ x 18 EL Max Input Power at antenna port 20 dBm before saturation 0 dBm before damage Output Power at antenna port Up to 21dBm 1dB Maximum Modulation OFDM modulation 1024 512 FFT points QPSK QAM16 QAM64 Access Method OFDMA FEC Convolutional Coding 1 2 2 3 3 4 5 6 BreezeMAX PRO 5000 CPE Product Manual Chapter 1 Products Description Specifications 1 3 2 Sensitivity Table 1 2 Sensitivity QPSK 1 2 96 93 QPSK 3 4 93 90 16QAM 1 2 89 86 16QAM 3 4 86 83 64QAM 2 3 81 78 64QAM 3 4 80 77 64QAM 5 6 79 76 1 3 3 IDU ODU Communication Table 1 3 ODU ODU Communication Cable Type Category 5E Outdoor Data Cable Double Jacket 4x2x24 FTP Maximum Length 90 meter 1 3
79. tion Server includes the following Menus E Show All on page 45 E Unit Control Parameters on page 46 E Registration Parameters on page 57 E BST AU Parameters on page 61 E Radio Parameters on page 65 E ATPC Parameters on page 70 E Performance Monitor on page 73 E Service Parameters on page 77 E Management Parameters on page 79 E Logout on page 80 BreezeMAX PRO 5000 CPE Q Product Manual Chapter 4 Operation Show All 4 4 Show All The Show All page enables viewing all the configurable parameters of the unit In addition the displayed information includes the general hardware and software properties of the units and relevant status details The display includes all the items available upon selecting the Show option for specific groups of parameters BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation Unit Control Parameters 4 5 Unit Control Parameters The Unit Control menu includes the following options Show Reset Unit Change Password SW Versions Control Configuration Control TM PM Files Control Ethernet Op Mode 4 5 1 Show Select this option to view the current values selected option of applicable parameters as well as general status information as follows E HW Details SU Type CPE Pro SQ CPE Family Describes the primary chipset of the CPE Sequans Serial Number Describes the serial number of the CPE unit This n
80. tworks Receive SU Alignment Unit Satellite Digital Audio Radio Service A satellite based direct broadcast radio service in which digitally encoded audio entertainment material is broadcast to earth based receivers from an orbiting satellite either directly or via a repeater station Session Initiation Protocol An application layer control IETF protocol that can establish modify and terminate multimedia sessions such as Internet telephony calls VoIP SIP can also invite participants to already existing sessions such as multicast conferences Media can be added to and removed from an existing session SIP transparently supports name mapping and redirection services which supports personal mobility users can maintain a single externally visible identifier regardless of their network location Product Manual Glossary SNMP SNR SU TCP TCP IP TDD TFTP TR 069 Tx UDP UL VLAN BreezeMAX PRO 5000 CPE Simple Network Management Protocol A network management protocol that provides a means to monitor and control network devices and to manage configurations statistics collection performance and security SNMP works by sending messages called protocol data units PDUs to different parts of a network SNMP compliant devices called agents store data about themselves in Management Information Bases MIBs and return this data to the SNMP requesters Signal to Noise Ratio The ratio of the amplitude of a
81. umber can be used to determine the identity of the subscriber unit by the BTS operator MAC Address This is the unit s LAN MAC address The WAN MAC address is the displayed address 1 MAC Address Control Number a number computed from the MAC Address that can be used for verification purposes Radio Band Describes the radio band in use currently only 5 GHz HW Version The version of the digital module BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation Unit Control Parameters HW Configuration RF Version The version of the radio module SU Interface Type 1D one data port Radio Type the receive Rx and transmit Tx capacity of the radio 1R 1T one receive Rx and one transmit Tx Antenna Type Dual slant antenna embedded E Ethernet Port Operation Mode parameters and status Ethernet Port Auto Negotiation Mode Enable Disable Ethernet Port Speed and Duplex E Operation Mode IPCS transparent delivery of IPv4 packets ETH CS transparent delivery of tagged 802 3 packets over Ethernet E Unit Status the connectivity status of the unit Possible statuses are Searching for Base Station Base station found Not Authorized Not Registered Registered E SW Versions SW Boot Version Main SW File Name Main SW Version Shadow SW File Name BreezeMAX PRO 5000 CPE O Product Manual Chapter 4 Operation Unit Control Para
82. unters Page The Link Quality Counters page displays the following counters E Current Fec Code E CINR dB the average Carrier to Interference and Noise Ratio of the signal BreezeMAX PRO 5000 CPE O Product Manual Chapter 4 Operation 4 10 2 CINRStd dB CINR Reuse 1 dB CINRStd Reuse 1 dB CINR Reuse 3 dB CINRStd Reuse 3 dB RSSI RSSIStd Last Tx Power dBm UL Fec Code Ethernet Counters Performance Monitor The Ethernet On Line Counters page displays RX and Tx levels for the Ethernet connection Ethernet On Line Counters Figure 4 17 Ethernet Counters Page BreezeMAX PRO 5000 CPE 6680 o o o ooo oo Product Manual Chapter 4 Operation Performance Monitor 4 10 3 The Ethernet On Line Counters table displays a continuously updated list of the traffic counters The display is updated every 2 seconds based on counters collected during this period The displayed counters include the following for each port LAN WAN and each direction TX RX E Bit Rate M Packet Rate E Total Bytes M Total Packets Rate counts are the average rate Bytes Packets per second for the last measurement interval 2 seconds Total counts are the accumulated number of Bytes Packets since the last unit reset or the last Counters Reset Integration Time The Integration Time page enables to set the frequency with which the CPE will monitor traffic statistics on both the WiMAX link and Ethernet
83. uring the parameters click Apply to save your changes BreezeMAX PRO 5000 CPE Q Product Manual Chapter 4 Operation Radio Parameters 4 8 4 8 1 4 8 2 Radio Parameters The Radio Parameters page includes the following options E Show M Frequency Scanning HM Antenna Selection Show The Show page displays the Frequency and Bandwidth selected by the scanning mechanism Show All parameters Radio parameters 10MHz Auto N A N A N A 10MHz Auto N A N A N A Figure 4 11 Radio Show Page Frequency Scanning The Frequency Scanning page enables viewing and updating the set of frequencies to be used during the scanning process The list of frequencies that participate in the scanning process includes a set of frequencies belonging to the scanning range and or a set of up to 10 discrete frequencies The scanning range is defined by Start Rx Frequency End Rx Frequency Scanning Main Step and Intermediate Steps The set of frequencies to be scanned is defined as follows The Main Frequencies are defined by the Start Frequency and Main Step using the formula F N Start Frequency N Main Step BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation Radio Parameters F 1 Start Frequency Main Step F 2 Start Frequency 2 Main Step End Frequency is the upper limit The Intermediate Steps can be used to define additional frequencies using a finer resolution The intermediate steps
84. wo combined signals differ in phase by 90 degrees this technique doubles the bandwidth by combining the two signals at the source before transmission transmitting digital data at a rate of 4 bits per signal change Quadrature Phase Shift Keying A data transfer technique used in coaxial cable networks that sends data using modulating signals Four different phases represent data with each signal s information determined by the signal before it For example if a phase stays the same from one signal to the other the information has not changed Remote Authentication Dial In User Service an authentication and accounting system used by many Internet Service Providers ISPs When you connect to the system you must enter your username and password This information is passed to a RADIUS server which checks that the information is correct and then authorizes access to the system Radio frequency An AC signal of high enough frequency to be used for wireless communications Received Signal Strength Indicator A signal or circuit that indicates the strength of the incoming received signal in a receiver Radio amp Telecommunications Terminal Equipment The R amp TTE Directive 1999 5 EC governs the marketing and use of R amp TTE equipment With the exception of a few categories of equipment the Directive covers all equipment which uses the radio frequency spectrum It also covers all terminal equipment attached to public telecommunication ne
85. z FCC 4940 4990 4 9 GHz Japan A 4900 5000 4 9 GHz Japan B 5030 5091 5 3 GHz ETSI 5150 5350 5 2 GHz ETSI 5150 5350 5 2 GHz FCC 5150 5350 5 3 GHz FCC 5250 5350 5 1 5 3 GHz FCC 5150 5350 5 1 GHz FAA 5090 5150 5 4 GHz Universal 5470 5900 5 9 GHz Universal 5900 5950 5 4 GHz ETSI 5470 5725 5 8 GHz ETSI 5725 5875 5 4 GHz FCC 5470 5725 5 8 GHz FCC 5725 5875 5 4 GHz Australia A 5490 5585 5 4 GHz Australia B 5655 5725 5 8 GHz Australia 5730 5840 5 8 GHz UK 5725 5845 BreezeMAX PRO 5000 CPE Product Manual Chapter 4 Operation Performance Monitor 4 10 4 10 1 Performance Monitor The Performance Monitor Page enables viewing performance monitoring of link quality and Ethernet counters and enables to set the monitoring intervals The CPE collects data on a regular basis and is able to deliver the data to the Access Control Server NMS Network Management Station upon request The Performance Monitor menu includes the following options E Link Quality Counters Page E Ethernet Counters E Integration Time Link Quality Counters Page The Link Quality On Line Display table displays read only information related to the quality of the link between the CPE and the BTS The display is updated every 2 seconds based on histograms counters collected during this period Link Quality On Line Display qam16 ctc 3 4 27 07 17 06 18 72 37 44 23 95 12 39 74 69 90 13 14 00 qam64 ctc 5 6 Figure 4 16 Link Quality Co