Home

Storport Miniport Driver

image

Contents

1. AutoPilot Installer Overview AutoPilot Installer runs after the driver kit is installed It can be run by Continuing the installation process after the driver kit installation completes Interactive installation at a later time Unattended installation AutoPilot Installer Features Command line functionality Initiates an installation from a command prompt or script Configuration settings can be specified on the command line Compatibility Verifies that the driver to be installed is compatible with the operating system and platform Driver and utility updates Installs and updates drivers and utilities Multiple adapter installation capability Installs drivers on multiple adapters alleviating the need to manually install the same driver on all adapters in the system Driver diagnostics Determines whether the driver is operating properly Silent installation mode Suppresses all screen output necessary for unattended installation Utility only installation AutoPilot Installer can skip driver installation if the driver on the system is the same as the driver AutoPilot Installer is about to install This functionality is available for attended and unattended installations Storport Miniport Driver User Manual Page 4 X EMULEX e Management Mode Setup Parameters in the AutoPilot Installer configuration file or on the command line determine if you can manage adapters locally and remotely and if the user can
2. answern Where question contains the text of the question to be asked explanation contains brief text to help explain the question The explanation will appear below the question in a smaller font If there is no explanatory text empty quotes must be used in its place answer0 contains the 1st answer to be displayed in the drop down list answer contains the 2nd answer to be displayed in the drop down list answern contains the nth answer to be displayed in the drop down list Storport Miniport Driver User Manual Page 21 X EMULEX For each question there can be as many answers as needed For each answer there must be a corresponding answer section with its corresponding driver parameters listed beneath it The answer uses the format answer 0 DriverParameter Paraml value Param2 value answer 1 DriverParameter Paraml value Param2 value answer n DriverParameter Paraml value Param2 value Example of STORPORT CONFIGURATION section STORPORT CONFIGURATION The first section contains the driver parameters common to all configurations no matter what answers are given DriverParameter EmulexOption 0 QUESTIONS question What is your link speed Note select Auto detect if you are unsure about the answer 4GB 2GB 1GB Auto detect ANSWER 0 DriverParameter LinkSpeed 4 4 GB ANSWER 1 DriverParameter LinkSpeed 2 2 GB ANSWER 2
3. d Uninstall_HBAnyware_CLI bat displayed an error message Uninstaller exited with code 0 The batch file cannot be found at the end of the execution The Uninstall HBAnyware_CLI bat did removed all the files which needed to remove This is a document issue The services are stopped and removed Click OK 5 At this point you can reinstall the utilities by running AutoPilot Installer To remove AutoPilot Installer a Select Emulex Storport Miniport Driver Kit or Emulex Storport Miniport Driver Core Kit Click Remove Click Yes The installer files are removed from the system Click OK Storport Miniport Driver User Manual Page 32 X EMULEX To uninstall the HBAnyware utilities and AutoPilot Installer on a Vista or Windows Server 2008 system 1 Open the Programs and Features control panel 2 Select Emulex HBAnyware or Emulex HBAnyware CLI in the program list and click the Uninstall icon in the tool bar above the program list If you have User Access Control enabled click Continue when asked for permission 3 Click Yes The application is removed from the system Click OK If you installed the full driver package a Select Emulex Common SAN Management b Click the Uninstall icon If you have User Access Control enabled click Continue when asked for permission c Click Yes The services are stopped and removed Click OK Note If you do not want to use the Control Panel you can execute a batch file to perform the
4. Discovery 0202 0262 0299 Link discovery events Mailbox 0310 0326 0399 Mailbox events INIT 0400 0463 0499 Initialization events FCP 0701 0749 0799 FCP traffic history events Link 1300 1306 1399 Link events Tag 1400 1401 1499 NPIV 1800 1804 1800 N_Port_ID virtualization events Storport Miniport Driver User Manual Page 43 X EMULEX Event Trace Messages ELS Log Messages 0100 0130 lpfc_mes0100 0100 FLOGI failure ulpStatus x x ulpWord 4 x x DESCRIPTION An ELS FLOGI command that was sent to the fabric failed SEVERITY Error LOG LOG_ELS verbose ACTION Check fabric connection SEE ALSO Ipfc_mes0110 Ipfc_mes0O101 0101 FLOGI completes successfully NPortld x x RaTov x x EdTov x x DESCRIPTION An ELS FLOGI command that was sent to the fabric succeeded SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0102 0102 PLOGI completes to NPortld x x DESCRIPTION The adapter performed a PLOGI into a remote NPort SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0103 0103 PRLI completes to NPortld x x TypeMask x x Fcp2Recovery x x DESCRIPTION The adapter performed a PRLI into a remote NPort SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0104 0104 ADISC completes to NPortld x x DESCRIPTION The adapter performed an ADISC into a remote NPor
5. HBAnyware Security Setup Completed window appears 4 Click Finish HBAnyware Utility Web Launch Procedures Installing the HBAnyware Utility Web Launch Feature In addition to the driver and HBAnyware utilities the following software must be installed before you can install the Web Launch feature e Microsoft Internet Information Services IIS Server See the Microsoft Web site for information on downloads and installation e Java Runtime Environment JRE See the http java com Web site for information on downloads and installation To install the HBAnyware Utility Web launch feature 1 Click Programs gt Emulex gt HBAnyware WebLaunch Install Web Launch installation begins 2 Type the URL address that you want HBAnyware Web Launch to use BG HBAnyware WebLaunch Update URL eat YS FS ee ee ee et ee Oe Oe ee OE EO EE OE MMM MMMM MMMM MM MMM MM Mm ka EMULEX HBANYWARE WEBLAUNCH JNLP UPDATE hehehehehe heheh d d d e e A e A A A M a e Emulex HB nyware WebLaunch has found the following IP address 138 239 87 66 Do you want to configure this IP address for HBAnyware WebLaunch Type y yes to use this IP address or Type n no to provide your own IP address or Type q to quit configuring IP address User input HBAnyware Web Launch Update URL screen Storport Miniport Driver User Manual Page 30 X EMULEX Updating the HBAnyware Utility Web Launch URL The driver HBAnyware utilities and HBAnyware Web Launc
6. all other adapter models minimum 3 11a5 This version of the driver is compatible with version 4 1 of the HBAnyware utility This is the version of HBAnyware that is included in the driver kit Version 4 1 of the HBAnyware utility is not compatible with earlier versions of the Emulex Storport Miniport driver on the same server Driver Kit Installer Overview The driver kit installer is an executable file that self extracts and copies the following software onto your system AutoPilot Installer Installs drivers and runs the HBAnyware utilities installer Storport Miniport driver Manages communication and data transfer between applications and I O devices using Emulex adapters as agents There are separate drivers for Emulex host bus adapters HBAs and converged network adapters CNAs ElxPlus driver Supports the HBAnyware utility persistent binding and LUN mapping and masking HBAnywere utility installer Installs HBAnyware utilities and services These monitor and perform configuration tasks on remote and local adapters HBAnyware Security Configurator Controls which HBAnyware systems can remotely access and manage adapters on other systems in a Storage Area Network SAN After the driver kit is installed you have three options Automatically run AutoPilot Installer immediately This is the default option See page 6 for more information Explicitly run AutoPilot Installer later on your system See page 6 for more info
7. change the remote management options once the utility is installed Note See Software Configuration Parameters on page 17 in the Unattended Installation topic for more information Management mode parameters govern both attended and unattended installations Text Only Installation Text based installation mode is used automatically when AutoPilot Installer runs on a server with the Server Core installation option of Windows Server 2008 During text based installations AutoPilot Installer interacts through a command prompt window AutoPilot Installer notifies you when the driver is installed and also gives you a chance to abort the installation Table 2 Supported Installation Modes Installation Kit Full Windows System Server Core System Full Driver Kit GUI Install Not Allowed Silent Install Core Driver Kit GUI Install Text based Install Silent Install Silent Install Whether it is launched from the command line or started programmatically Windows always starts AutoPilot Installer as a separate stand alone task This means that AutoPilot Installer will have its own command prompt window and cannot access others Installing the Driver Kit To install either the full driver kit or the core driver kit 1 Download the driver kit installer from the Emulex Web site to your system There is one driver kit installer for the full driver kit and one driver kit installer for the core driver kit Only one dri
8. host from other hosts is alowed Full Management The utilty manages the HBAs on this host and other hosts that allows it Management of HBAs on this host from othes hosts is allowed E Read only Management The utity cannot peifoim senstive operations Other hosts must be used to change settings or update firmware V Allow users to change the management mode alter installing the wilty Ces Figure 1 Utilities Installation Management Mode Setup 5 Click Next Installation automatically continues to completion A dialog box will be displayed if Windows requires a reboot View the progress of the installation Once the installation is successful a Finish page appears View or print a report if desired e View Installation Report The installation report is a text file with current Emulex adapter inventory configuration information and task results e Print Installation Report The Windows print dialog is displayed to select options for printing the installation report Click Finish to exit AutoPilot Installer If your system requires a reboot as indicated in step 5 you must do so before using the drivers or utilities Storport Miniport Driver User Manual Page 9 X EMULEX Software First Installation The driver kit installer must be downloaded from the Emulex Web site and installed on your system Either the full or core driver package may be installed only one can be installed on a system To perform a software
9. in Windows Server 2003 or username Documents in Windows Server 2008 Vista and version is the driver package version identifier You can specify a different AutoPilot Installer kits folder when you select the Create AutoPilot Installer Kits option See Configuring an AutoPilot Installer Kit on page 15 for more information on creating a custom kit Hardware First Installation or Driver and Utility Update The driver kit installer must be downloaded from the Emulex Web site and installed Either the full or the core package may be installed only one can be installed on a system Note To update the Storport Miniport driver begin the following procedure at step 2 To perform a hardware first installation 1 Install a new Emulex adapter and power on the system If the Windows Found New Hardware wizard is displayed click Cancel to exit AutoPilot Installer performs this function Note If there are multiple adapters in the system the Windows Found New Hardware wizard appears multiple times Click Cancel to exit the wizard each time it appears Storport Miniport Driver User Manual Page 7 X EMULEX 2 Run AutoPilot Installer using any of the options listed in the Running a Software Installation Interactively on page 6 3 When the AutoPilot Installer Welcome page appears select an adapter in the list and click Next Installation continues Specific considerations e Ifyou are replacing a SCSlport Miniport
10. DriverParameter LinkSpeed 1 1 GB ANSWER 3 DriverParameter LinkSpeed 0 Auto detect question Describe the topology of your storage network Note Select Arbitrated Loop when directly connected to the array no fibre switch Select Point to Point when connected to a SAN fibre switch Arbitrated Loop Point to Point ANSWER 0 DriverParameter Topology 2 ANSWER 1 DriverParameter Topology 3 ENDQUESTIONS END STORPORT CONFIGURATION Storport Miniport Driver User Manual Page 22 X EMULEX QFE Checks STORPORT QFES To add a Windows Quick Fix Engineering QFE check to the configuration file edit the STORPORT QFES section in the AutoPilot Configuration file You may place this section anywhere within the file as long as it is not contained within another section This section contains a single line for each QFE that is to be checked Up to 10 lines will be checked more than that may exist but they will be ignored All parameters in each line must be specified These lines have the format qfe qfe name path and file name file version applicable Os qfe name The name of the item being checked For example QFE 838896 The name should facilitate searching Microsoft s Web site for any required code updates path and file name This string identifies the file to be checked and its location relative to the Windows home folder In most cases the file to check will be the Microsoft
11. Emulex Technical Support 0xA0 Port object construction failed OxA4 Unsupported OCB command code aa with byte 0x11 aa 0xCO Failed to allocate un cached extension 0xC1 Port initialization failure 0xC2 Utility mailbox command timeout 0xC3 Fatal over temperature condition 0xC4 Over temperature warning condition 0xC5 Over temperature warning condition alleviated OxC6 Invalid response OCB OxC7 Initialization failed due to exceeding max driver instances 256 0xC8 Initialization failed due to STORPORT SYS revision level too low Installed Microsoft KB level must be 932755 or higher if such KB is not installed the driver installation kit will not load the 2 20 driver OxEC Failed to allocate authentication context Table 8 Malfunction Errors Bits 0 7 Interpretation 0x0C Set variable failed 0x26 Spurious mailbox attention 0x31 Unrecognized mailbox completion command code 0x33 Invalid link state 0x36 Initialization command failed status in bits 8 31 0x3B Discovery error due to lack of resources insufficient RPIs Ox3E Unable to create discovered node object Ox3F Failed to issue ELS process login PRLI command 0x45 Retries exhausted to ELS FLOGI 0x47 Failed to issue UNREG_VPI 0x48 No exchange available for extended link service request ELS command 0x4C Exhausted retries on ELS PLOGI 0x53 WWPN mismatch on ADISC response 0x54 WWNN mismatch o
12. For example the command line all on one line Storport Miniport Driver User Manual Page 14 X EMULEX storportminiportkit 2 20 006 exe APargs ReportLocation C Documents and Settings Administrator My Documents reports results in AutoPilot Installer being run as APInstall exe ReportLocation C Documents and Settings Administrator My Documents reports If you have many parameters to pass to AutoPilot Installer or if you wantto do so repeatedly then it may be less error prone to run the driver kit installer interactively delay AutoPilot Installer execution and then run the AutoPilot Installer command yourself The procedure for doing so is described in the Option 2 Run AutoPilot Installer Separately on page 6 and Performing an Unattended Installation on page 13 Configuring an AutoPilot Installer Kit To configure an AutoPilot Installer kit 1 Create an AutoPilot Installer Kits folder by using the Create AutoPilot Installer Kits option of the full driver kit See Option 3 Create an AutoPilot Installer Kit on page 13 By default the driver kit will create a folder named Documents Emulex AutoPilot Installer Kit version Installers where Documents is your Documents folder named My Documents in Windows Server 2003 and version is the driver package version identifier However you may specify a different loca tion for the folder Open a command prompt window and cd to the folder created by the drive
13. Software Configuration Parameters on page 17 For attended hardware first utility updates 1 Run AutoPilot Installer using any of the options listed in the Running a Software Installation Interactively on page 6 Storport Miniport Driver User Manual Page 10 X EMULEX 2 When the AutoPilot Installer Welcome page appears click Next The Driver Installation Issue page is displayed SE AutoPilot Installer v7 3 3 11 Driver Installation Issue potential issue has been discovered during driver installation The driver being installed is the same version as the curently installed deiwer Skip the diver installation and install the wilties Driver to be installet FC Stomort Miniport Driver 7 2 10407 Adapter Current civer LPe11000 M4 PCI bus 4 device 0 function 0 10 00 00 00C3 FC Stoipon Minion Driver 7 2 1047 Sooo A Figure 3 Driver Installation Issue 3 Select the Skip the driver installation and install the utilities check box and click Next To stop installation click Cancel 4 View or print a report if desired e View Installation Report The installation report is a text file with current Emulex adapter inventory configuration information and task results e Print Installation Report The Windows print dialog is displayed to select options for printing the installation report 5 Click Finish to exit AutoPilot Installer If the system needs to reboot you are prompted to do so
14. The HBAnyware utility manages the adapters on this host and other hosts that allow it Management of adapters on this host from other hosts is also allowed e Read Only Management If you select this check box the HBAnyware utility cannot perform configuration tasks such as changing driver parameter values or updating firmware e This option cannot be checked if Strictly Local Management is selected e If Local Management Plus is selected the HBAnyware utility can view information about the adapters on this host but cannot change the information e If Full Management is selected the HBAnyware utility can view information about the adapters on this host and other hosts that allow it but cannot change the information In both cases other hosts can view and manage the local host s adapters Storport Miniport Driver User Manual Page 8 X EMULEX e To prevent the management mode from being changed after installation clear the Allow users to change the management mode after installing the utility check box SE AutoPilot Installer v7 3 3 11 E Utilities Installation pp AutoPilot Installer is preparing to install management utilities on this host Select a management type and click Next FS Strictly Local Management The utilty only manages the HBAs on this host Other hosts are not allowed to manage the HBAs on this host Local Management Plus The utity only manages the HBAs on this host Management of HBAs on this
15. automatically invoke APInstall exe with its silent switch See the Performing an Unattended Installation on page 13 for more information If you specify a value for the APargs driver kit parameter this value will be appended to the APInstall exe command line See Command Line Parameter Settings on page 16 for more information on the AutoPilot Installer settings that may be specified in the APargs value For example assume the driver kit file you downloaded from the Emulex web site is named storportportminiportkit_2 20 006 exe If you execute this installer file as storportminiportkit_2 20 006 exe q APargs ManagementMode Full then after installing AutoPilot Installer the driver kit will automatically execute it as APInstall exe silent ManagementMode Full To specify more than one AutoPilot Installer parameter separate the settings by one or more spaces and put quotes around the entire APargs expression For example the command line all on one line storportminiportkit _2 20 006 exe APargs ManagementMode ReadOnly ManagementModeChangeable FALSE results in AutoPilot Installer being run as APInstall exe ManagementMode ReadOnly ManagementModeChangeable FALSE AutoPilot Installer parameter values that contain spaces such as path names must be enclosed in quotes To add such a setting to APargs you must insert backslashes before the quotes around the value and then add quotes around the entire APargs expression
16. driver and the complete HBAnyware utility set including a Graphical User Interface GUI and a Command Line Interface CLI The full driver kit also provides an option to create AutoPilot Installer kits that you can customize and distribute on your network Although the full driver kit will not install on the Server Core installation option of Windows Server 2008 Server Core it can be used to create kits for those platforms e Core Installation Driver kit core driver kit Includes the Emulex Storport Miniport driver and the HBAnyware utility CLI but not the HBAnyware utility GUI The core driver kit is required for use with Server Core platforms You can only customize the core driver kit on the system where it is installed It cannot be used to create AutoPilot Installer Kits for other platforms Run one of the driver kit installers to extract all of the software needed for an installation then complete the installation using AutoPilot Installer You can install a driver by any of the following methods Note These installation methods are not mutually exclusive Hardware first installation At least one Emulex adapter is installed before you install the Emulex drivers and utilities Software first installation You can install drivers and utilities using AutoPilot Installer prior to the installation of any adapters You do not need to specify the model of any adapters to be installed later The appropriate drivers and utilities a
17. number of outstanding I Os per device is expected to exceed 32 increase this parameter to a value greater than the number of expected I Os per device up to a maximum of 254 The QueueDepth parameter defaults to 32 If 32 is set and not a high enough value performance degradation may occur due to Storport throttling its device queue CoalesceMsCnt CoalesceMsCnt defaults to zero If you are using a performance evaluation tool such as IOMETER and if you expect the I O activity will be greater than 8000 I Os per second set CoalesceMsCnt to 1 and reinitialized with an adapter reset or system reboot CoalesceRspCnt CoalesceRspCnt defaults to 8 For all other values up to the maximum of 63 the adapter will not interrupt the host with a completion until either CoalesceMsCnt milliseconds has elapsed or CoalesceRspCnt responses are pending The value of these two driver parameters reduces the number of interrupts per second which improves overall CPU utilization However there is a point where the number of I Os per second is small relative to CoalesceMsCnt and this will slow down the completion process causing performance degradation Performance Testing Examples Test Scenario One You execute IOMETER with an I O depth of 1 I O per device in a small scale configuration 16 devices In this case the test does not exceed the adapter s performance limits and the number of I Os per second are in the low thousands Recommendation set CoalesceMsCn
18. responded to with an error condition the target and LUN information along with the SCSI status are provided In the specific case of code Ox9B this code indicates that the device responded with the specific status of Check Condition the ASC ASCQ information provided in bytes 0x12 and 0x13 will allow you to find out what status is being reported by the target and see if there is some action that can be performed to return the device to functional status Nameserver Response code 0x98 This code is useful in determining if the expected number of targets in a SAN configuration are being presented by the nameserver to the requesting HBA The number in byte 0x11 is the number of targets returned to the nameserver query made by the HBA if the number of targets does not match expectations examine the SAN configuration found in the switch tables and if that information shows targets or devices still missing check connections between the switch ports and those devices Context Allocation Failures There are a number of event codes for which the interpretation contains the phrase context allocation failure these types of events are referring to the internal memory constructs of the Emulex Storport Miniport driver and as such are intended for Emulex design engineer s information If a customer encounters such an event they should contact Emulex support for analysis and determination if that particular event may be an indicator of a failed HBA
19. specified with the following string TimeOutValue 0x3C where the number is the timeout value in seconds e Additional Quick Fix Engineering QFE Checks STORPORT QFES This section can specify additional QFE check also known as KB Knowledge Base updates during installation This section can appear anywhere within the file as long as it is not contained within another section Lines that begin with a semicolon are comments Some of the comments are sample settings To use the setting remove the semicolon Storport Miniport Driver User Manual Page 20 X EMULEX Using the Windows Environment Variable ProgramFiles You can use the Windows ProgramFiles environment variable in the LocalDriverLocation UtilitiesLocation and ReportLocation strings within the configuration file This allows you to specify strings in a driver independent manner allowing the same configuration file to be used on different systems where Windows may have been installed on different drives To use this option ProgramFiles must be the first component specified in the string The portion of the string that follows will be appended to the contents of the ProgramFiles environment variable Note The contents of the ProgramFiles environment variable is not terminated with a slash so one must be provided in the string Windows environment variables are not case sensitive UtilitiesLocation ProgramFiles my company our utilities Configurati
20. to fully the manage adapters on this host To set this parameter set the parameter value to one of the names listed above Example ManagementMode LocalOnly Note If this setting is not specified and a utility upgrade is being performed the existing value of this setting will be retained Storport Miniport Driver User Manual Page 18 X EMULEX ManagementModeChangable Changing Management Mode Default True By default you can change the management mode after the HBAnyware utility is installed by selecting the Management Mode parameter in the HBAnyware utility s File menu If the ManagementMode parameter is disabled and the ManagementModeChangable parameter is set to false you must reinstall the HBAnyware utility to change the management mode Note If this setting is not specified in the configuration file and a utility upgrade is being performed the existing value of this setting will be retained HideManagementModeGuUI Hiding the Management Mode Configuration Default True The Utilities Installation page can be displayed by Autopilot Installer See Figure 1 on page 9 The page is displayed only if this parameter is set to false AutoPilot Installer then reads the configuration file parameters and uses those settings to pre select the appropriate options in the page If this parameter is omitted from the configuration file or explicitly set to true the page is not displayed AutoPilot Installer will u
21. 0701 0701 Issue Abort Task Set to Pathld x x Targetld x x Lun x x DESCRIPTION The driver has issued a task management command for the indicated SCSI device address SEVERITY Warning LOG LOG_INIT verbose ACTION Review system configuration Ipfc_mes0703 0703 Issue LUN reset to Pathld x x Targetld x x Lun x x Did x x DESCRIPTION Storport is requesting a reset of the indicated LUN SEVERITY Warning LOG LOG_INIT verbose ACTION Review system configuration Possible side effect of cluster operations Ipfc_mes0713 0713 Issued Target Reset to PathId d Targetld d Did x x DESCRIPTION Storport detected that it needs to abort all I O to a specific target This results in login reset to the target in question SEVERITY Warning LOG LOG_FCP verbose ACTION Review system configuration Possible side effect of cluster operations SEE ALSO Ipfc_mes0714 Ipfc_mes0714 0714 Issued Bus Reset for PathId d DESCRIPTION Storport is requesting the driver to reset all targets on this adapter SEVERITY Warning LOG LOG_FCP verbose ACTION Review system configuration Possible side effect of cluster operations SEE ALSO Ipfc_mes0713 Ipfc_mes0716 0716 FCP Read Underrun expected d residual d DESCRIPTION FCP device provided less data than was requested SEVERITY Supplement Information LOG LOG_FCP verbose ACTION No action needed informational SEE ALSO Ipfc_mes0730 Ipfc_mes0729 0729 FCP comma
22. 2 bb byte 0x13 cc The Appendix has more information see ASC ASCQ on page 65 Storport Miniport Driver User Manual Page 60 X EMULEX Table 9 Command Errors Continued Bits 0 7 Interpretation 0xA3 Local error on FCP command completion received Local Reject to FCP command LOCAL REJECT STATUS of aa with byte 0x11 aa prior to leaving HBA OxA6 Data over run OxA7 Non specific FCP error info in bits 8 31 OxA9 Local error received Local Reject to FCP command LOCAL REJECT STATUS of aa with byte 0x11 aa after leaving HBA The Appendix has more information see Local Reject Status on page 65 0xAB CT Pass through command SRB STATUS aa with byte 0x11 aa The Appendix has more information see SRB Status on page 65 0xAC Local error on report LUN completion LOCAL REJECT STATUS aa returned as during Report LUN completion with byte 0x11 aa The Appendix has more information see Local Reject Status on page 65 Table 10 Event Indications Bits 0 7 Interpretation 0x21 Port re initialization complete now off line 0x22 Port shutdown complete 0x23 Port re initialization complete now on line OxA5 Data under run residual in bits 8 31 0xDO NPIV Virtual Port creation success Virtual Port index ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc 0xD1 NPIV Virtual Port creation failed Virtual Port in
23. 446 0446 Adapter failed to init CONFIG_RING mbxStatus x x DESCRIPTION Adapter initialization failed when issuing CFG_RING mailbox command SEVERITY LOG LOG_INIT verbose ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0454 0454 Adapter failed to init INIT_LINK mbxStatus x x DESCRIPTION Adapter initialization failed when issuing INIT_LINK mailbox command SEVERITY Error LOG LOG_INIT verbose ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0458 0458 Bring Adapter online DESCRIPTION The FC driver has received a request to bring the adapter online This may occur when running HBAnyware SEVERITY Warning LOG LOG_INIT verbose ACTION None required Ipfc_mes0460 0460 Bring Adapter offline DESCRIPTION The FC driver has received a request to bring the adapter offline This may occur when running HBAnyware SEVERITY Warning LOG LOG_INIT verbose ACTION None required Ipfc_mes0463 0463 Adapter firmware error hostStatus x x Info1 OxA8 x x Info2 OxAC x X DESCRIPTION The firmware has interrupted the host with a firmware trap error SEVERITY Error LOG LOG_INIT verbose ACTION Review HBAnyware diagnostic dump information Storport Miniport Driver User Manual Page 49 X EMULEX FCP Log Messages 0701 0749 Ipfc_mes
24. 7 Name server command context allocation failure contact Emulex Technical Support Ox6E Close XRI command context allocation failure contact Emulex Technical Support Ox6F State change registration failure 0x70 ELS receive context allocation failure contact Emulex Technical Support 0x72 ELS receive PLOGI context allocation failure contact Emulex Technical Support 0x74 Mailbox context allocation failure contact Emulex Technical Support 0x77 Mailbox context allocation failure contact Emulex Technical Support Ox7A ELS receive LOGO context allocation failure contact Emulex Technical Support 0x7D Mailbox context allocation failure contact Emulex Technical Support Ox7E Mailbox context allocation failure contact Emulex Technical Support Ox7F Mailbox context allocation failure contact Emulex Technical Support 0x80 Mailbox context allocation failure contact Emulex Technical Support 0x81 Mailbox context allocation failure contact Emulex Technical Support 0x84 ELS FDISC context allocation failure contact Emulex Technical Support 0x85 Mailbox context allocation failure contact Emulex Technical Support 0x88 ELS PLOGI command context allocation failure contact Emulex Technical Support Storport Miniport Driver User Manual Page 58 X EMULEX Table 7 Severe Errors Continued Bits 0 7 Interpretation 0x89 ELS RSCN registration command context allocation failure contact
25. D 11 in Source elxstor cannot be found The local computer may not have the necessary registry information or message DLL files to display messages from a remote computer You may be able to use the AUXSOURCE flag to retrieve this description see Help and Support for details The follovang information is part of the event Device RadPortd Data Bytes Words oooo Of 00 10 00 0100 68 00 h A 0008 00 00 00 00 Ob 00 04 e0 0010 9b 00 29 00 00 00 00 00 ooi Sen v Figure 6 Event Properties Storport Miniport Driver User Manual Page 55 X EMULEX Severity Scheme When the Event Viewer is launched there are three branches Application Security and System All ELXSTOR error log entries are found under the System branch and all ELXSTOR error log entries have the Event Viewer severity level of error e A severe error code indicates that the driver firmware or adapter is behaving abnormally and your intervention is required to correct the problem e A malfunction error code indicates that there is a problem with the system but your intervention is not required Acommand error code indicates that an event has transpired but does not require your intervention An event may be problem oriented such as an invalid fabric command sub type An event may not be problem oriented such as exhausted retries on PLOGI or PDISC Related Driver Parameter LogError The LogError driver parameter de
26. FALSE LocalDriverLocation path specifier UtilitiesLocation path specifier ReportLocation path specifier ManagementMode LocalOnly LocalPlus LocalReadOnlyPlus ReadOnly Full HideManagementModeGUI TRUE FALSE ManagementModeChangeable TRUE FALSE Path Specifiers Paths may be specified as e an explicit path ReportLocation C Program Files Emulex AutoPilot Installer Reports Note The double quotes are required for values that contain spaces such as the value above e a relative path LocalDriverLocation Drivers Storport Miniport assuming installation into C Program Files Emulex AutoPilot Installer this path would logi cally become C Program Files Emulex AutoPilot Installer Drivers Storport Miniport Storport Miniport Driver User Manual Page 16 X EMULEX e with the ProgramFiles environment variable UtilitiesLocation ProgramFiles Emulex AutoPilot Installer Utilities Configuration File Location The optional setting ConfigFileLocation contains the path to the configuration file that should be used If this parameter is not specified AutoPilot Installer will use the file named APInstall cfg in the same folder as APInstall exe The format is the same as that of the other path settings Example APInstall silent SkipDriverInstall True ManagementModeChangeable True configFileLocation MyConfiguration cfg Software Configuration Parameters DiagEnable Runni
27. LOG_ELS verbose ACTION No action needed informational Ipfc_mes0236 0236 Issuing command to name server type x x DESCRIPTION The driver is issuing a nameserver request to the fabric Also recorded if a GID_FT is sent SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational SEE ALSO Ipfc_mes0239 or lpfc_mes0240 Ipfc_mes0238 0238 NameServer response DID count d DESCRIPTION Received a response from fabric name server with N DIDs SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0239 0239 NameServer Response next DID value x x DESCRIPTION The driver received a nameserver response And this message is recorded for each DID included in the response data SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational SEE ALSO Ipfc_mes0236 lpfc_mes0240 0240 NameServer Response Error CmdRsp x x ReasonCode x x Expla nation x x DESCRIPTION The driver received a nameserver response containing a status error SEVERITY Error LOG LOG_DISCOVERY verbose ACTION Check Fabric configuration The driver recovers from this and continues with device discovery SEE ALSO Ipfc_mes0236 Ipfc_mes0256 0256 Start node timer on NPortld x x timeout value d DESCRIPTION Starting timer for disconnected target with NPort ID and timeout value SEVERITY Information LOG LOG_ELS verbose ACTION No actio
28. Miniport Driver Parameters Continued Parameter Definitions Activation Requirement ExtTransferSize ExtTransferSize is an initialization time parameter that affects the Reboot maximum SGL that the driver can handle which determines the maximum I O size that a port will support At the default of 0 the maximum transfer size is 512KB With a value of 1 the maximum transfer size is 1MB With a value of 2 the maximum transfer size is 2MB Value 0 2 Default 0 disabled FrameSizeMSB n FrameSizeMSB controls the upper byte of receive FrameSize if Reset issued in PLOGI This allows the FrameSize to be constrained on 256 byte increments from 256 1 to 2048 8 Value 0 8 Default 0 InitTimeout n Determines the number of time out seconds during driver initialization Reboot for the link to come up If the link fails to come up by InitTimeout driver initialization exits but is still successful If the link comes up before InitTimeout the driver sets double the amount for discovery to complete Value 5 30 seconds or 0x5 0x1E hex Default 15 seconds OxF LinkSpeed n LinkSpeed has significance only if the adapter supports speeds other Reset than one Gb s Value Auto select 1 Gb s 2 Gb s 4 Gb s 8 Gb s Default Auto select Note Setting this option incorrectly can cause the HBA to fail to initialize LinkTimeOut n LinkTimeOut applies to a private loop only A timer is started on all Dynamic mapp
29. Requirement TraceBufSiz n TraceBufSiz sets the size in bytes for the internal driver trace buffer The internal driver trace buffer acts as an internal log of the driver s activity Value 250 000 2 000 000 or 0x3D090 0x1E8480 hex Default 250 000 0x3D090 Reboot Storport Miniport Driver User Manual Page 42 X EMULEX Troubleshooting Introduction There are several circumstances in which your system may operate in an unexpected manner The Troubleshooting section contains reference tables on event codes and error messages and provides information regarding unusual situations Event Tracing Windows Server 2003 SP1 and later only Trace messages are part of the Emulex Ipfc log messages Storage Event Tracing supports two types of events e FFInit 0x00000001 events that occurred at HwFindAdapter and Hwilnitialize e FFlo 0x00000002 events that occurred during I O Storage Event Tracing supports four levels of events e DbgLviErr 0x00000001 error level e DbGLvlIWrn 0x00000002 warning level e DbgLvilnfo 0x00000004 Information level e DbgLvilnfo 0Ox00000008 excessive information level Note To view trace messages you must enable Event Tracing in the operating system See your Microsoft operating system documentation for more information Table 6 Event Tracing Summary Table a From To e Verbose Description ELS 0100 0130 0199 ELS events
30. Storport driver for example system32 drivers storport sys This string is also used in dialogs and log file messages file version This is the minimum version that the file to be checked must have for the QFE to be considered installed It is specified as a text string using the same format as is used when displaying the files property sheet For example 5 2 1390 176 applicable OS This is used to determine if the QFE applies to the operating system platform present The acceptable values are Win2003 Win2008 and WinVista Example STORPORT QFES qfe QFE 83896 system32 drivers storport sys 5 2 1390 176 Win2003 Setting Up Driver Parameters STORPORT PARAMS To change driver parameters modify this section of the AutoPilot Configuration file Locate the STORPORT PARAMS section in the AutoPilot Configuration file This section follows Optional Configuration File Changes Under the STORPORT PARAMS heading list the driver parameters and new values for the driver to use For example Driver Parameter LinkTimeout 45 See the HBAnyware Utility User Manual for a listing of driver parameters defaults and valid values Setting Up System Parameters SYSTEM PARAMS To change the system parameters create a SYSTEM PARAMS section in the APInstall cfg file Create this section in the Optional Configuration File Changes heading in the AUTOPILOT CONFIG section of the AutoPilot Configuration f
31. X EMULEX Storport Miniport Driver Version 2 20 for Windows Server 2003 Windows Server 2008 Server Core Installation Option of Windows 2008 User Manual P003588 01A Rev A Critical Connectivity Solutions X EMULEX Copyright 2003 2009 Emulex All rights reserved worldwide No part of this document may be reproduced by any means or translated to any electronic medium without the prior written consent of Emulex Information furnished by Emulex is believed to be accurate and reliable However no responsibility is assumed by Emulex for its use or for any infringements of patents or other rights of third parties which may result from its use No license is granted by implication or otherwise under any patent copyright or related rights of Emulex Emulex the Emulex logo AutoPilot Installer AutoPilot Manager BlockGuard Connectivity Continuum Convergenomics Emulex Connect Emulex Secure EZPilot FibreSpy HBAnyware InSpeed LightPulse MultiPulse OneCommand OneConnect One Network One Company SBOD SLI and VEngine are trademarks of Emulex All other brand or product names referenced herein are trademarks or registered trademarks of their respective companies or organizations Emulex provides this manual as is without any warranty of any kind either expressed or implied including but not limited to the implied warranties of merchantability or fitness for a particular purpose Emulex may make improvements and changes to th
32. after a driver is installed AutoPilot Installer s default behavior in unattended installations is not to restart the system AutoPilot Installer continues with the installation and you must restart at a later time Restarts often require you to login as part of the Windows start up process and without logging in the installation process would hang if it restarted the system However Windows can be configured to start up without requiring you to login You must make sure it is safe to restart the system during unattended installations if you are going to set this parameter to true InstallWithoutQFE Enabling Installation if a QFE Check Fails Default False AutoPilot Installer checks for Microsoft s Quick Fix Engineering updates QFEs also known as KB Knowledge Base updates based upon the checks you have specified in the STORPORT QFES section By default the installation will terminate if the QFE check should fail To enable a driver installation to proceed even if a check for QFEs should fail set this parameter to true AutoPilot Configuration File The AutoPilot Configuration file is organized into sections grouped according to related commands There are six main sections Each section begins with a heading The heading is required even if there are no settings in the section The only section not required is the Installation Prompts section which has the heading STORPORT CONFIGURATION That section cannot exist if AutoPilot Insta
33. after you click Finish For software first utility updates 1 Run AutoPilot Installer A dialog appears asking if you want to perform a software first installation of the drivers and utilities or just an installation of utilities 2 Select Utilities Only Installation proceeds View the progress of the utility installation Once the utility installation is successful a congratulations window appears 3 View or print a report if desired see details in step 4 of the previous procedure Click Finish to exit AutoPilot Installer Storport Miniport Driver User Manual Page 11 X EMULEX Diagnostics Once the AutoPilot Installer finishes the Diagnostics window is displayed Figure 4 shows a successful installation P AutoPilot Installer 7 3 3 11 Diagnostics The list below shows the results of AutoPilot Installers diagnostics When you have finished viewing the diagnostic results click Next To rerun the diagnostics click Rerun All Diagnostics Passed Adapter Location Driver Fimware Link state LPe12000 Slot 3 PCI bus 9 device 0 f Passed Passed Figure 4 AutoPilot Installer Diagnostics Note AutoPilot Installer can be run again from the Start menu Programs gt Emulex gt AutoPilot Installer or APInstall exe can be run from a command prompt If the installation fails the Diagnostics window shows that the adapter failed If the adapter fails 1 Select the adapter to view the reaso
34. an existing ElxPlus driver from the desktop Note Only one instance of the Emulex PLUS driver should be installed even if you have multiple adapter ports installed in your system 10 11 12 Run the driver kit installer but do not run AutoPilot Installer See Running a Software Installation Interactively on page 6 for instructions on how to do this Select Start gt Administrative Tools gt Computer Management Click Device Manager left pane Click the plus sign next to the Emulex PLUS class right pane to show the ElxPlus driver entry Right click the ElxPlus driver entry and select Update Driver from the menu Select No not this time Click Next on the Welcome to the Hardware Update Wizard window Click Next Select Install from a list or specific location Advanced and click Next Select Don t Search will choose the driver to install Click Have Disk Direct the Device Wizard to the location of driver s distribution kit If you have installed the driver installer kit in the default folder the path is C Program Files Emulex AutoPilot Installer Drivers Storport x86 for the 32 bit driver version or C Program Files Emulex AutoPilot Installer Drivers Storport x64 for the x64 driver version or C Program Files Emulex AutoPilot Installer Drivers Storport l A64 for the Itanium driver version Click OK Select Emulex PLUS Click Next to install the driver Click Finish The El
35. available before the NodeTimeout interval expires the OS is notified so that any associated devices if the node is a target can be removed If the node becomes available before NodeTimeout expires the timer is canceled and no notification is made Value 1 255 seconds or 0x0 OxFF hex Default 30 0x1E PerPortTrace PerPortTrace enables driver tracing for a single adapter port It is a Dynamic diagnostic tool and may be used by developers or Technical Support While global tracing is always enabled for all ports per port tracing is more specific and temporary Value 1 2 Default 0 disabled QueueDepth n QueueDepth requests per LUN target see QueueTarget parameter Dynamic If you expect the number of outstanding I Os per device to exceed 32 then you must increase to a value greater than the number of expected I Os per device up to a value of 254 If the QueueDepth value is set too low a performance degradation can occur due to driver throttling of its device queue Value 1 254 or 0x1 OxFE hex Default 32 0x20 Storport Miniport Driver User Manual Page 40 X EMULEX Table 5 Storport Miniport Driver Parameters Continued Parameter Definitions Activation Requirement QueueTarget n QueueTarget controls I O depth limiting on a per target or per LUN Dynamic basis If set to 0 depth limitation is applied to individual LUNs If set to 1 depth limitation is applied across the entire targe
36. ction needed informational 1904 Authentication ends for x x with status x x Yd d DESCRIPTION Authentication is done SEVERITY Information LOG LOG_FCSP verbose ACTION No action needed informational 1905 Authentication policy change for local x 08x x 08x remote x 08x 08x DESCRIPTION Authentication policy has been changed SEVERITY Information LOG LOG_FCSP verbose ACTION No action needed informational Storport Miniport Driver User Manual Page 54 X EMULEX Error Log Viewing the Error Log The system event log is a standard feature of Windows Server 2003 All events logged by the Emulex Storport Miniport will be Event ID 11 with source elxstor To view the error LOG 1 Open the Event Viewer window e Click Start gt Programs gt Administrative Tools gt Event Viewer or e Right click on My Computer Manage and Event Viewer in Computer Management The Event Viewer window is displayed Double click any event with the source name ELXSTOR Examine the entry at offset 0x10 and Event ID 11 The Emulex event code is found in byte 0010 and supplementary data is in the byte offsets 0011 through 0013 in example Figure 6 byte 0010 9b byte 0011 00 byte 0012 29 and byte 0013 00 Event Properties 12 x Event Date ier Sowce elxstor Time amp 52 19PM Categoy None Type Enor EventID 11 User NZA Ba Computer EMULEX D4C6E58E _a Description The description for Event I
37. dations based upon the number of I Os per adapter Table 4 Recommended Settings for I O Coalescing OSs per Second ae a ae eae I Os lt 10000 0 8 10000 lt I Os lt 18000 1 8 18000 lt I Os lt 26000 1 16 1 Os gt 26000 1 24 CoalesceMsCnt The CoalesceMsCnt parameter controls the maximum elapsed time in milliseconds that the adapter waits before it generates a CPU interrupt The value range is 0 63 decimal or 0x0 Ox3F hex The default is 0 and disables I O Coalescing CoalesceRspCnt The CoalesceRspCnt parameter controls the maximum number of responses to batch before an interrupt generates If CoalesceRspCnt expires an interrupt generates for all responses collected up to that point With CoalesceRspCnt set to less than 2 response coalescing is disabled and an interrupt triggers for each response The value range for CoalesceRspCnt is 1 255 decimal or 0x1 OxFF hex The default value is 8 Note A system restart is required to make changes to CoalesceMsCnt and or CoalesceRspCnt Storport Miniport Driver User Manual Page 35 X EMULEX Performance Testing There are three driver parameters that need to be considered and perhaps changed from the default for better performance testing QueueDepth CoalesceMsCnt and CoalesceRspCnt Note Parameter values recommended in this topic are for performance testing only and not for general operation QueueDepth If the
38. ded to improve performance on tape devices supporting a larger block size Changing Driver Types If you currently use a SCSlport Miniport or FC Port driver the driver will be replaced when you install Storport Miniport driver version 2 20 Sorport Miniport driver version 2 20 will be installed for all HBAs on the server You will also lose your customized driver parameters persistent bindings LUN masking and LUN mapping The default parameters set with AutoPilot Installer will usually be the best options However you may want to note your current settings before you install Storport Miniport driver version 2 20 After the installation you can then update your customized driver parameters Note This update process can leave files associated with old driver kits on your system After running AutoPilot Installer and restarting your system you may be required to uninstall old driver or utility program entries Follow the procedures in the Uninstalling Programs section in the Storport Miniport driver User Manual Ensure you delete only previous driver and utility versions Minimum Software Requirements AutoPilot Installer will not let you perform an installation if the minimum Windows service pack or Microsoft Storport driver update is not installed Storport Miniport Driver Information Prerequisites One of the following operating systems e Windows Server 2003 SP2 running on an x86 x64 or Itanium server e Windows Server 2008 r
39. des Explanation Code Link Service Reject LS_RJT 0x01 Accept ACC 0x02 N_Port Login PLOGI 0x03 Fabric Login FLOGI 0x04 N_Port Logout LOGO 0x05 Process Login PRLI 0x20 Process Logout PRLO 0x21 Discover F_Port Service Params FDISC 0x51 Discover Address ADISC 0x52 Register State Change Notify RSCN 0x61 SCSI Status The SCSI status returned from a SCSI device which receives a SCSI command Table 15 SCSI Status Codes Explanation Code GOOD 0x00 CHECK CONDITION 0x02 BUSY 0x08 RESERVATION CONFLICT 0x18 QUEUE FULL 0x28 Storport Miniport Driver User Manual Page 64 Local Reject Status X EMULEX Codes supplied by the Emulex HBA firmware which indicate why a command was failed by the HBA Table 16 Local Reject Status Codes Explanation Code SEQUENCE TIMEOUT Possible bad cable link noise 0x02 INVALID RPI Occurs when link goes down 0x04 NO XRI Possible host or SAN problem 0x05 TX_DMA FAILED Possible host system problem 0x0D RX_DMA FAILED Possible host system problem Ox0E ILLEGAL FRAME Possible bad cable link noise OxOF NO RESOURCES Port out of exchanges or logins 0x11 LOOP OPEN FAILURE FC_AL port not responding 0x18 LINK DOWN Queued cmds returned at link down 0x51A OUT OF ORDER DATA Possible bad cable or noise 0x1D SRB Status SCSI Request Block status provided by
40. dex ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc 0xD2 NPIV Virtual Port FDISC failed Virtual Port index ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc 0xD3 NPIV Virtual Port memory allocation failed Virtual Port index ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc 0xD4 Exceeded maximum Virtual Port supported Virtual Port index ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc 0xD5 NPIV Virtual Port removal Virtual Port index ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc OxE0O Authenticated successfully Virtual Port index ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc OxE1 Failed to authenticate Virtual Port index ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc OxE2 Authentication not supported Virtual Port index ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc OxE3 Authenticated ELS command timeout Virtual Port index ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc OxE4 Authentication transaction timeout Virtual Port index ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc OxE5 LS_RJT other than Logical Busy received for Authentication transaction Virtual Port index ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc OxE6 LS_RJT Logical Busy received for Authentication transaction Virtual Port index ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc OxE7 Received Authentication Reject other than Restart Virtual Port index ccbbaa with byte 0x11 aa byte 0x12 bb b
41. e server share Emulex x64 core kit if errorlevel 1 echo Creation of Emulex _x64 core_kit failed Storport Miniport Driver User Manual Page 15 X EMULEX AutoPilot Installer Command Line Parameters The syntax used to run AutoPilot Installer silently from a command line or script is APInstall silent parameter setting parameter setting The silent switch and parameter settings can occur in any order One or more spaces must separate the switch and each parameter setting Command Line Parameter Settings The syntax of a parameter setting is parameter name value Double quotes are required only around values that contain spaces Spaces may separate parameters equal signs and values Parameter names and values are not case sensitive The APiInstall command may contain the settings listed below Each setting except ConfigFileLocation may also be specified in the AutoPilot Configuration file For descriptions of each parameter see Software Configuration Parameters on page 17 Settings specified in the APInstall command override those specified in the configuration file ConfigFileLocation path specifier NoSoftwareFirstInstalls TRUE FALSE SilentRebootEnable TRUE FALSE ForceDriverUpdate TRUE FALSE ForceDriverTypeChange TRUE FALSE SkipUtilityInstall TRUE FALSE SkipDriverInstall TRUE FALSE InstallWithoutQFE TRUE FALSE ForceRegUpdate TRUE
42. e product described in this manual at any time and without any notice Emulex assumes no responsibility for its use nor for any infringements of patents or other rights of third parties that may result Periodic changes are made to information contained herein although these changes will be incorporated into new editions of this manual Emulex disclaims any undertaking to give notice of such changes DH CHAP Notice License Copyright c 1998 2006 The OpenSSL Project All rights reserved This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit http www openssl org SSLeay License Copyright C 1995 1998 Eric Young eay cryptsoft com All rights reserved This product includes cryptographic software written by Eric Young eay cryptsoft com This product includes software written by Tim Hudson tjh cryptsoft com Windows DH CHAP Notice Derived from the RSA Data Security Inc MD5 Message Digest Algorithm Copyright C 1991 2 RSA Data Security Inc Created 1991 All rights reserved Emulex 3333 Susan Street Costa Mesa CA 92626 Storport Miniport Driver User Manual Page ii ma Table of Contents gt gt EMULEX Installation naiara a a a aa a aE a S aaa e a aa a E 1 aiigete LiKe t e a MEEA EAE A A A E A E E A E 1 Important Considerations coiii aa a aa a a aa aa 2 New in This Release ecic aaa aaa aiaiai ia aaa Ta 2 Changing Driver Typos cciana AAEN AAA AAAA AAAA 2 Minimum Software Requir
43. e way targets are assigned SCSI IDs Discovered Reboot targets are assigned persistent SCSI IDs according to the selected binding method Persistent bindings do not take effect with the driver in stand alone mode If set to 0 automap is disabled Uses the HBAnyware utility to persistently set the SCSI address of a discovered FCP capable FC node target If set to 1 automap by WWNN If set to 2 automap by WWPN If set to 3 automap by DID Value 0 3 Default 2 Class n Class selects the class of service on FCP commands Dynamic If set to 2 class 2 If set to 3 class 3 Value 2 3 Default 3 CoalesceMsCnt n CoalesceMsCn specifies wait time in milliseconds to generate an Reset interrupt response if CoalesceRspCnt has not been satisfied Zero specifies an immediate interrupt response notification A non zero value enables response coalescing at the specified interval in milliseconds Value 0 63 decimal or 0x0 Ox3F hex Default 0 0x0 Storport Miniport Driver User Manual Page 37 X EMULEX Table 5 Storport Miniport Driver Parameters Continued Parameter Definitions Activation Requirement CoalesceRspCnt n CoalesceRspCn specifies the number of response entries that trigger Reset an Interrupt response Value 0 255 decimal or 0x1 OxFF hex Default 8 0x8 DiscoveryDelay n DiscoveryDelay controls whether the driver waits for n seconds
44. ecommended QFE or Service Pack was not installed 2399141899 0x8F00000B Unattended installation did not find any drivers of the type specified in the config file 2399141900 0x8FO0000C A silent reboot was attempted but according to the operating system a reboot is not possible 2399141901 0x8F00000D GUI Mode only A driver package download was cancelled 2399141902 0x8F00000E Non Enterpri se No adapters were found in the system 2399141903 0x8F00000F A required QFE or Service Pack was not detected on the system 2399141836 0x8F000030 AutoPilot Installer was not invoked from an account with Administrator level privileges 2391419952 0x8F000040 AutoPilot Installer has detected unsupported adapters on the system 2399141968 0x8F000050 Unattended software first installations are disallowed 2399141984 0x8F000060 User cancelled APInstall before any driver utility installation occurred 2399142000 0x8F000070 User cancelled APInstall after driver utility installation occurred 2399142016 0x8F000080 An attempt to install a full apps kit on a Server Core system was detected 2399142032 0x8F000090 APInstaller encountered an error while parsing the command line Report file contains details 2399142048 0x8F0000A0 Converged Network Adapters CNAs are installed but are not supported on IA64 systems Storport Miniport Driver User Manual Page 24 X EMULEX AutoPilot Installer Installation Reports During each installation AutoPi
45. ed targets using the link timeout value If the timer expires before discovery is re resolved commands issued to timed out devices returns a SELECTIION_TIMEOUT The Storport driver is notified of a Bus change event which leads to the removal of all LUNs on the timed out devices Value 1 500 seconds or 0x0 OxFE hex Default 30 0x1E Storport Miniport Driver User Manual Page 39 X EMULEX Table 5 Storport Miniport Driver Parameters Continued Parameter Definitions Activation Requirement LogErrors n LogErrors determine the minimum severity level required to enable Dynamic entry of a logged error into the system event log Errors are classified as severe malfunction or command level A severe error requires user intervention to correct a firmware or adapter problem An invalid link speed selection is an example of a severe error A malfunction error indicates that the system has problems but user intervention is not required An invalid fabric command type is an example of a malfunction error A command level error an object allocation failure is an example of a command error If set to 0 all errors are logged If set to 1 command level errors are logged If set to 2 malfunction errors are logged If set to 3 severe errors are logged Value 0 3 Default 3 NodeTimeout n The node timer starts when a node i e discovered target or initiator Dynamic becomes unavailable If the node fails to become
46. eeeeeeeees 63 Event Log Interpretation cccccccccceceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 63 Additional Event Log Informattion cccccccccccceceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeetees 63 ELS FCP Command Error Status Codes cccccccccccceeseeeeeeeeeeeeeteeeeeteeeeees 63 CT Command Response Codes ceceeeeccneeeeeeeeeeeeeceaeeeeeeeeeeeeeeaaaees 63 FC CT Reject Reason Codes ccccccccceeeeeeeeeeeeeee tees ttt 64 ELS Command Codes i assanis irinn AA 64 SCIS IUS a E T T 64 Local Reject Status o cccicciiinsinnnnntannnanatannaannnannaaaanennnaaananananananananmananananane 65 ORB Status a S 65 PS GI ASC O ara o a a 65 Additional Notes on Selected Error Codes ccccccccceceeeeeeeeeeeeeeeeeeeeeeeeeees 66 Storport Miniport Driver User Manual Page iv X EMULEX Installation Introduction AutoPilot Installer for Emulex Storport Miniport drivers provides installation options that include simple installations with a few mouse cicks custom unattended installations that use predefined script files and text only installations AutoPilot Installer is included with Emulex drivers and utilities in Windows executable files driver kit installers that you can download from the Emulex Web site There are two types of driver kits that can install the Emulex Storport Miniport driver and utilities e Full Installation Driver kit full driver kit Includes the Emulex Storport Miniport
47. eeeeeenenenegs 37 Troubleshooting scsi E 43 Lele Ufo O annn EENEN EEEO ENEE 43 Event Tracing Windows Server 2003 SP1 and later only 43 Event Trace MeSSages 2 2 cccecceececeeeeeencneeecnegeeeeeeeedeeddeedetedeceedeedesnenmemeeneseneee 44 ELS Log Messages 0100 0130 eeeeeteeeeeetetettcieeeeeeeeeeeeeeeeeeeeeees 44 Discovery Log Messages 0202 0262 0 tteeteeettttttttttttttttteee 45 Mailbox Log Messages 0310 0326 oo eetttttettetteetttttetttaeeeeeees 48 INIT Log Messages 0400 0463 eeeeeseeeeeeeetteeeeeeeeeeeeeeeeeeeeeeeeeeeees 48 FCP Log Messages 0701 0749 oo eee eeeeeeeeeteeeteeteetetetetetteaaaeeeeeees 50 Link Log Messages 1302 1306 cccceccceeeeeeeeeeeeeeeeeeaeeeaaeaaaaaaaaaaeeeeeees 52 Tag Messages 1400 1401 ccceeeteeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeteeeteness 52 NPIV Messages 1800 1899 0 eee aaa 53 ELS Messages 1900 1999 eee teeeettttttetettttteetttaeaaaaaaaaaaaaeeeeeees 53 ENO LO 55 Viewing the Error LOG cccccccccceeeee sree AEE TE 55 Severity SCHEME 20 cece cece e cece eeeeeeeeeeeeeeeeneeeeneeeeees 56 Related Driver Parameter LOQESr0r ccccccccceeteteeeeeeeeeeeeeeeteettiteiniaeeeeeees 56 Format of an Error Log Entry saiia a EAE EANNA 56 Error Codes Tables scccacccaansscracdecastveasdededeadandedndadndadadadedadndadindedindadindesindsindedisdls 57 APPONI cc i EEEE EET 63 Supplemental Event Log Information cc ceeeeeeeeeeeeeeeeeeeeeeeeeeeeaaaeeee
48. eived SEVERITY Error LOG LOG_LINK_EVENT verbose ACTION If numerous link events are occurring check physical connections to the FC network Ipfc_mes1306 1306 Link Down timeout DESCRIPTION The link was down for greater than the configuration parameter HLinkTimeOut seconds All I O associated with the devices on this link will be failed SEVERITY Warning LOG LOG_LINK_EVENT verbose ACTION Check adapter cable connection to SAN Tag Messages 1400 1401 Ipfc_mes1400 1400 Tag out of range ContextIndex x x MaxIndex x x ulpCommand x x DESCRIPTION Firmware has generated an invalid response SEVERITY Error LOG LOG_LINK_EVENT verbose ACTION Review hardware configuration Contact Emulex Technical Support Ipfc_mes1401 1401 Invalid tag ContextIndex x x ulpCommand x x DESCRIPTION Firmware has generated an invalid response SEVERITY Error LOG LOG_LINK_EVENT verbose ACTION Review hardware configuration Contact Emulex Technical Support Storport Miniport Driver User Manual Page 52 X EMULEX NPIV Messages 1800 1899 Ipfc_mes1800 1800 NPIV FDISC failure VPI x x Error x x Reason x x DESCRIPTION Virtual Port fails on a FDISC to the switch with the error and reason listed SEVERITY Error LOG LOG_NPIV verbose ACTION Check to ensure the switch supports NPIV Ipfc_mes1801 1801 Memory allocation failure for NPIV port x x DESCRIPTION Fails to allocated the block of memory for the Virtual Po
49. ement eececeeececceeeeeeeeeeeeeeeeeeeeeeeeeeaaeeaaaees 2 Storport Miniport Driver Information ccccccccceeeeeeeeeeeeeeaeeeeeeeeeeeeeeeaaeeeeeeeeeeeeeaas 2 Driver Kit Installer Overview 0 cccceeecceceeeeeeeeeeeeeeeaaaeeaeeeeeeeeseeaaaeeeeeeeseseeaaeeaes 3 Files Installed by the Driver Kit Installer cccccccceceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 4 AutoPilot Installer Overview cceceecceeeeeeeeeeeeeeeeeeeeaaeeaeeeeeeeeeeaaeaeeeeeeeeaeeeaaaaaes 4 AutoPilot Installer Features cccccceecececceeceeeeeeeeeeeeeaeeeeeeeeeeeeesaaaeaeeeeeeeeeesaas 4 Text Only Installation 0 cceccccccecceeeeeeeeeeeeeeeeeaeaeeeeeeeeeeeeaeeeeeeeeesaaaaeeeeseteeeeees 5 Installing the Driver Kit ll nl nn nn I nnn nn iii 5 Starting Installers from a Command Prompt or Script ceeeeeeeeeeeeeneneeeeeeeees 6 Running a Software Installation Interactively ccccceeeeeeeeeeeeeeeeeeeeeeeeeaaeeaaaeeees 6 Hardware First Installation or Driver and Utility Update cc cceeeeeteeeeeees 7 Software First Installation ccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeecaaaeeeeeeeeeeeeeaaeeneneeees 10 Utility Only Update seccare REEERE 10 B e elgen or ae ee ere errr rere 12 Performing an Unattended Installation ccccccccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 13 Driver Kit Installer Command Line Parameters cceeeeeeeeeeeeeeeeeeeeeeen
50. er does not affect any existing persistent bindings To set up an installation to remove the existing driver parameters from the registry and replace them with parameters specified in the AutoPilot Configuration file set this parameter to true Note You can also use this setting for attended installations with the AutoPilot Installer wizard if you modify the AutoPilot Configuration file in an AutoPilot Installer Kit Storport Miniport Driver User Manual Page 17 X EMULEX SkipUtilitylnstall Installing Driver Without Utilities Default False You can set up an unattended installation to install the driver without installing the utilities package By default the utilities are automatically installed with an unattended installation To set up an installation without utilities set this parameter to true LocalDriverLocation Specifying Location to Search for Drivers Default Drivers The default Drivers folder is located in the same folder as AutoPilot Installer You can specify a local location that is to be searched for drivers during unattended installations The location may be a local hard drive or a network share Removable media are not searched Example localDriverLocation d drivers new Storport Note On x64 and 32 bit systems the path specified by LocalDriverLocation must contain at least one instance of both an ElxCna for CNAs and ElxStor for HBAs and CNAs driver AutoPilot Installer will automatica
51. er2ok none2 if not errorlevel 1248 goto noreport2 echo No adapter found goto server2ok noreport if not errorlevel 110 goto nocfg2 echo Could not open installation report file goto server2ok nocfg2 if not errorlevel 87 goto badcfg2 echo Invalid configuration file parameters goto server2ok badcfg2 if not errorlevel 2 goto server2ok echo No appropriate driver found server2ok Storport Miniport Driver User Manual Page 26 X EMULEX Manual Installation and Updating Procedures Manually Installing or Updating the Storport Miniport Driver Overview You can install or update the Storport Miniport driver and utilities manually without using AutoPilot Installer The Emulex PLUS ElxPlus driver supports the HBAnyware utility persistent binding and LUN mapping and masking The ElxPlus driver must be installed before you install the Storport Miniport driver Removing the Adjunct Driver Registry Key The ElxPlus driver replaces the adjunct driver that was used with Storport Miniport 1 11a3 or earlier If currently installed the adjunct driver registry key must be removed using the deladjct reg file before you install the ElxPlus driver The deladjct reg file was extracted when you installed the old driver Manually Installing the Emulex PLUS ElxPlus Driver for the First Time To install the ElxPlus driver from the desktop Note Only one instance of the Emulex PLUS driver should be installed even if you have multiple adapter
52. first installation 1 Run AutoPilot Installer using any of the options listed in the Running a Software Installation Interactively on page 6 The following message appears S AutoPilot Installer Warning 1 AutoPilot Installer cannot find any Emulex Fibre Channel HBAs in this system gt AutoPilot Installer can perform a driver pre installation allowing you to install your HBV Click OK to pre instal drivers or click Cancel to stop the installation FJ cea Figure 2 AutoPilot Installer Warning Software First Installation 2 Click OK A Welcome page appears 3 Click Next Installation automatically completes View the progress of the installation Once the installation is successful a Finish Page appears 4 View or print a report if desired e View Installation Report The installation report is a text file with current Emulex adapter inventory configuration information and task results e Print Installation Report The Windows print dialog is displayed to select options for printing the installation report 5 Click Finish to exit AutoPilot Installer Utility Only Update You can reinstall or update a utility without reinstalling the Storport Miniport driver This option is only available if the Storport Miniport driver in the driver kit installer is the same version as the driver that is already installed on the system For unattended installations the ForceDriverUpdate setting must be set to false See
53. for example a script similar to the following would run remote execution remd server1 g autopilot x86_full_kit apinstall if errorlevel 1 goto serverlok echo AutoPilot reported an error upgrading Server 1 if not errorlevel 2147483650 goto unsupported echo Configuration file missing goto serverlok unsupported if not errorlevel 2147483649 goto older echo Unsupported operating system detected older if not errorlevel 2001 goto none echo The driver found is the same or older than the existing driver goto serverlok none if not errorlevel 1248 goto noreport echo No Emulex adapter found goto serverlok noreport if not errorlevel 110 goto nocfg echo Could not open installation report file goto serverlok nocfg if not errorlevel 87 goto badcfg Storport Miniport Driver User Manual Page 25 X EMULEX echo Invalid configuration file parameters goto serverlok badcfg if not errorlevel 2 goto serverlok echo No appropriate driver found serverlok remd server2 g autopilot ApInstall ConfigFileLocation g autopilot mysetup apinstall cfg if errorlevel 1 goto server2ok echo AutoPilot reported an error upgrading Server 2 if not errorlevel 2147483650 goto unsupported echo Configuration file missing goto server2ok unsupported if not errorlevel 2147483649 goto older echo Unsupported operating system detected older2 if not errorlevel 2001 goto none2 echo The driver found is the same or older than the existing driver goto serv
54. h must be installed before you can update the URL To change the IP address for HBAnyware Web Launch 1 Copy Web Launch related files to a sub folder called WebLaunch in the HBAnyware installation folder 2 Click on Programs gt Emulex gt HBAnyware WebLaunch Update URL Storport Miniport Driver User Manual Page 31 X EMULEX Uninstallation Uninstalling HBAnyware Web Launch To uninstall HBAnyware Web Launch but leave the HBAnyware utility installed 1 Select Start gt Programs gt Emulex gt HBAnyware WebLaunch Uninstall The following screen appears 56 HBAnyware WebLaunch Uninstall PUPPET rrrrrrrreerrrrrr rrr rrr rrrrrrrrrr rT EMULEX HBANYWARE WEBLAUNCH UNINSTALLATION DD REE HEE HEE Uninstalling VebLaunchSrv service DONE Deleting hbanyware jnlp file DONE Deleting HBAnyware VebLaunch directory DONE Uninstallation conplete Press any key to continue Figure 5 HBAnyware Web Launch Uninstallation screen 2 HBAnyware Web Launch is removed Press any key to continue Uninstalling Programs To uninstall the HBAnyware utilities and AutoPilot Installer on a Windows Server 2003 system 1 Open the Add or Remove Programs control panel 2 Select Emulex HBAnyware or Emulex HBAnyware CLI in the program list and click Remove 3 Click Yes The application is removed from the system Click OK 4 Ifyou installed the full driver package a Select Emulex Common SAN Management b Click Remove c Click Yes
55. he adjunct driver prior to manually installing a new driver To remove the adjunct driver registry settings 1 Browse to the Storport Miniport driver version 1 20 or later driver kit that you downloaded and extracted 2 Double click on the deladjct reg file A Registry Editor window appears to confirm that you want to execute deladijct reg 3 Click Yes The elxadjct key is removed from the registry Storport Miniport Driver User Manual Page 34 X EMULEX Configuration Introduction The Emulex Storport Miniport driver has many options that you can modify to provide for different behavior You can set Storport Miniport driver parameters using the HBAnyware version 4 1 utility See the HBAnyware version 4 1 User Manual for information on using this utility to configure the driver Server Performance I O Coalescing I O Coalescing is enabled and controlled by two driver parameters CoalesceMsCnt and CoalesceRspCnt The effect of I O Coalescing will depend on the CPU resources available on the server With I O Coalescing turned on interrupts are batched reducing the number of interrupts and maximizing the number of commands processed with each interrupt For heavily loaded systems this will provide better throughput With I O Coalescing turned off the default each I O processes immediately one CPU interrupt per I O For systems not heavily loaded the default will provide better throughput The following table shows recommen
56. ile Storport Miniport Driver User Manual Page 23 X EMULEX AutoPilot Installer Exit Codes AutoPilot Installer sets an exit code to indicate whether an installation was successful or an error occurred These exit codes allow AutoPilot Installer to be used in scripts with error handling In unattended installations AutoPilot Installer sets the following exit codes Table 3 Unattended Installation Error Codes Error Code Hex Description 0 0x00000000 No errors 2399141889 0x8F000001 Unsupported operating system detected 2399141890 0x8F000002 The AutoPilot Configuration file is not found 2399141891 0x8F000003 Disabled adapters detected in the system 2399141892 0x8F000004 The selected driver is 64 bit and this system is 32 bit 2399141893 0x8F000005 The selected driver is 32 bit and this system is 64 bit 2399141894 0x8F000006 Installation activity is pending AutoPilot Installer cannot run until it is resolved 2399141895 0x8F000007 GUI Mode only User cancelled execution because user did not wish to perform a software first install 2399141896 0x8F000008 No drivers found 2399141897 0x8F000009 One or more adapters failed diagnostics 2399141904 0x8F000010 GUI Mode only User chose to install drivers even though a recommended QFE or Service Pack was not installed 2399141920 0x8F000020 GUI Mode only User chose to stop installation because a r
57. ile before running AutoPilot Installer The configuration file is typically in C Program Files Emulex AutoPilot Installer APInstall cfg Uncomment the line that sets SilentInstallEnable to True There are other settings in the same section of the configuration file related to unattended installations that you may also want to edit See Software Configuration Parameters on page 17 for more information After editing the file you can run AutoPilot Installer from the Start menu a command prompt or a script Option 3 Create an AutoPilot Installer Kit e Run the full driver package installer and choose the Create AutoPilot Installer Kits option Then do one of the following e Create AutoPilot Installer kits using the makekit cmd script makekit script as described in the Configuring an AutoPilot Installer Kit on page 15 Run APInstall exe in the kit folder you create specifying the silent switch e For customized settings edit the AutoPilot Installer configuration file as previously described except edit the file Documents Emulex AutoPilot Installer Kit version Installers APInstall cfg instead of the one in Program Files Create AutoPilot Installer kits using the makekit script as described in Configuring an AutoPilot Installer Kit on page 15 Run APInstall exe in the kit folder you create See Starting Installers from a Command Prompt or Script on page 6 for important information on running the instal
58. iver for THO FIPSE TIME oaeaeei a E E a a E 27 Manually Updating the Emulex PLUS ElxPlus Driver 28 Manually Installing or Updating the Fibre Channel Storport Miniport Driver cccceeeeeeeeeeceeaeeeeeeeeeeeecaaaeeeeeeeeeeeeeaaaaeeeeeeees 28 Manually Installing the Driver Utilities ec eeeeeeeeeeeeeeeeeeeeeeaaaaaeeeeees 29 HBAnyware Security Configurator ce cccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeetees 30 Installing the HBAnyware Security Configurator ees 30 Storport Miniport Driver User Manual Page iii ma Table of Contents gt gt EMULEX HBAnyware Utility Web Launch Procedures 00 ieee 30 Installing the HBAnyware Utility Web Launch Feature eee 30 Updating the HBAnyware Utility Web Launch URL ccccecceeeeeeteeeteeteteeeeees 31 FINS TAN AON sssi E 32 Uninstalling HBAnyware Web Launch ccececeeceeeeeeeeeeseeeeeeeaaaaaaaaaaaaaeeeeeees 32 Uminstaling Programs ccce eed liecetateiebetetsteheteteletetetslesetaiaiabeiana 32 Uninstalling the Emulex DriverS eeeeeeeseeesssrrrnssesssssssssssssnssssnnssneniinennnnnnns 34 CONPIQUIATION cerei EEEE 35 DAVE OCU CHOON s a a 35 Server PerfOrmMancCe e EEEE i i 35 VO CodlesT Ngesot aniei ee fete levied E N EATER 35 Performance TeSting cccccccccccecceececeeeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 36 Driver Parameters for WiNdOWS cccececeeeeeeeeee eee eeeee eee eeeeeeeeeeeeeeeeeeeee
59. ler from a command prompt or script Storport Miniport Driver User Manual Page 13 X EMULEX When in unattended installation mode AutoPilot Installer does the following 1 Reads the configuration file 2 Reads any options that may be specified on the command line overriding the configuration file settings as appropriate Opens the installation report file Validates the operating system Discovers adapters and records the adapter inventory in the report file Verifies mandatory configuration file parameters DEDO C eD Searches for drivers to be installed based on the LocalDriverLocation setting in the configuration file 8 If appropriate verifies that the selected driver is a different type than the currently installed driver or more recent version of the currently installed driver 9 Copies the driver parameters from the configuration file into the registry for the driver s coinstaller 10 Installs updates the driver 11 Rediscovers adapters and records the updated adapter inventory in the report file 12 Records the final results and closes the report file Driver Kit Installer Command Line Parameters You can pass command line parameters to AutoPilot Installer yet still have it run automatically by the driver kit if you run the driver kit installer from a command prompt or script If you specify the q switch with the driver installer command the driver installer will run in unattended mode and it will
60. lid Illegal response OCB Ox2E Invalid response OCB OX2F Invalid response IOCB 0x30 Mailbox context allocation failure contact Emulex Technical Support 0x34 Mailbox context allocation failure contact Emulex Technical Support 0x35 Mailbox context allocation failure contact Emulex Technical Support 0x37 Mailbox context allocation failure contact Emulex Technical Support 0x3D Mailbox context allocation failure contact Emulex Technical Support 0x41 Mailbox context allocation failure contact Emulex Technical Support 0x42 Mailbox context allocation failure contact Emulex Technical Support 0x44 ELS FLOGI command context allocation failure contact Emulex Technical Support 0x47 Mailbox context allocation failure contact Emulex Technical Support 0x4D Mailbox context allocation failure contact Emulex Technical Support 0x51 Request to ADISC a non existent node 0x52 ELS ADISC command context allocation failure contact Emulex Technical Support 0x56 Mailbox context allocation failure contact Emulex Technical Support 0x57 Mailbox context allocation failure contact Emulex Technical Support 0x58 ELS LOGO command context allocation failure contact Emulex Technical Support 0x5C ELS PRLI command context allocation failure contact Emulex Technical Support Ox5E ELS RLIR command context allocation failure contact Emulex Technical Support 0x64 Create XRI command context allocation failure contact Emulex Technical Support 0x6
61. lized command context allocation failure OxA8 Read check error residual amount ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc OxAA A node timeout occurred on DID ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc OxFO Spurious link attention OxF 1 Spurious link attention with previous state change Table 9 Command Errors Bits 0 7 Interpretation 0x32 Insufficient context for attention handling 0x49 ELS command error aa with byte 0x11 aa The Appendix has more information see FC CT Reject Reason Codes on page 64 0x4A ELS command failure 0x90 ELS FDISC completed to DID ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc 0x91 ELS LOGO completed to DID ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc 0x92 ELS LOGO received from fabric 0x93 ELS FLOGI completed to DID ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc 0x94 ELS PLOGI completed to DID ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc 0x95 Discovered SCSI target wirh DID ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc 0x96 ELS RSCN of type aa received with byte 0x11 aa 0x97 SCSI ID of cc assigned to SCSI target with DID of XXaabb with byte 0x11 aa byte 0x12 bb byte 0x13 cc and XX not reported 0x98 Nameserver response with aa targets number of targets reported with byte 0x11 aa 0x9B SCSI Check Condition at Target ID aa with ASC ASCQ of bb cc with byte 0x11 aa byte 0x1
62. ller will be run in silent mode You must delete or comment out that entire section for unattended installation The sections and their headings are e Configuration Identification AUTOPILOT ID This section appears at the beginning of every AutoPilot Configuration file This section contains revision and label information The revision entry identifies the file s version number and the date on which it was produced The label entry is used to identify the configuration that the file supports This section can appear only once in the AutoPilot Configuration file e Software Configuration AUTOPILOT CONFIG This section can contain settings that control and configure AutoPilot Installer and the HBAnyware utility operation This section can appear only once in the AutoPilot Configuration file e Installation Prompts STORPORT CONFIGURATION This section can contain questions that must be answered during the initial installation process This section applies to attended installations only this section must not be present in configuration files to be used with unattended installations e Driver Parameters STORPORT PARAMS This section can specify driver parameters Parameters are read exactly as they are entered and are written to the registry e System Parameters SYSTEM PARAMS This section can adjust the operating system s global disk timeout The timeout is stored in the registry under the key HKML CurrentControlSet Services disk and
63. lly select the most recent revisions that it finds For IA64 systems only ElxStor drivers are supported NoSoftwareFirstinstalls Prohibiting Software First Installations Default False When this parameter is set to true AutoPilot Installer prevents unattended installations from performing software first installations This way you can execute an automated installation on multiple machines in your network but only machines with Emulex adapters will actually have Emulex drivers updated or installed ManagementMode Managing Emulex Adapters Default LocalPlus This parameter controls how the HBAnyware utility manages local and remote adapters The ManagementMode parameter works with the ManagementModeChangable and HideManagementModeGuUI parameters e LocalOnly The utility only manages the adapter on this host and no remote management of adapters is allowed e LocalPlus The utility only manages the adapters on this host Management of adapters on this host from other hosts is allowed e Full The utility manages the adapters on this host and other hosts that allow it Management of adapters on this host from other hosts is also allowed e LocalReadOnlyPlus The utility has read only access to the adapters on this host Remote hosts must be used to fully manage the adapters on this host e ReadOnlyPlus The utility has read only access to the adapters on this host and other hosts that allow it Remote hosts must be used
64. lot Installer produces a report describing events that occurred during the installation This report has several sections The first section provides basic information including the time and date of the installation the name of the machine that the installation was performed on the version number of AutoPilot Installer and the identification of the configuration file that was used The second section provides an inventory of the Emulex adapters as they were before AutoPilot Installer performed any actions The third section lists the tasks that AutoPilot will perform in the order they will be done The fourth section records the results of each task When all driver installation tasks are completed an updated adapter inventory is recorded Note If you cancel AutoPilot Installer that information is recorded along with when you cancelled the installation The contents of any error dialogs that are displayed are also recorded Command Script Example Modifying the configuration file enables you to script the installation of a system s driver The following example command script batch file assumes that you have made mandatory changes to the AutoPilot Configuration file as well as any desired optional changes If your systems were set up with a service that supports remote execution then you can create a command script to remotely update drivers for all of the systems on the storage net If Microsoft s RCMD service was installed
65. n LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0215 0215 RSCN processed DID x x DESCRIPTION Processed RSCN from fabric SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0225 0225 Device Discovery completes DESCRIPTION This indicates successful completion of device re discovery after a link up SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0229 0229 Assign SCSIId x x to WWN word 0 x x WWN word 1 x x NPortld x X DESCRIPTION The driver assigned a SCSI ID to a discovered mapped FCP target BindType 0 DID 1 WWNN 2 WWPN SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0230 0230 Cannot assign SCSIld to WWN word 0 x x WWN word 1 x x NPortld X X DESCRIPTION SCSI ID assignment failed for discovered target SEVERITY Warning LOG LOG_ELS verbose ACTION Review system configuration Ipfc_mes0232 0232 Continue discovery at sequence number d PLOGIs remaining d DESCRIPTION NPort discovery sequence continuation SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Storport Miniport Driver User Manual Page 46 X EMULEX Ipfc_mes0235 0235 New RSCN being deferred due to RSCN in process DESCRIPTION An RSCN was received while processing a previous RSCN SEVERITY Information LOG
66. n Possible side effect of cluster operations REMARK See also Message 0713 0748 Lun reset complete Pathld x x Targetld x x Lun x x DESCRIPTION A LUN reset operation has completed SEVERITY Warning LOG LOG_FCP verbose ACTION Review system configuration Possible side effect of cluster operations REMARK See also Message 0703 0749 Abort task set complete Did x x SCSIld x x DESCRIPTION A task management has completed SEVERITY Warning LOG LOG_FCP verbose ACTION Review system configuration Possible side effect of cluster operations REMARK See also Message 0701 Storport Miniport Driver User Manual Page 51 X EMULEX Link Log Messages 1302 1306 Ipfc_mes1302 1302 Invalid speed for this board d forced link speed to auto DESCRIPTION The driver is re initializing the link speed to auto detect SEVERITY Warning LOG LOG_LINK_EVENT verbose ACTION None required Ipfc_mes1303 1303 Link Up event tag x x link speed dG topology 0 Pt2Pt 1 AL d DESCRIPTION A link up event was received It is also possible for multiple link events to be received together SEVERITY Error LOG LOG_LINK_EVENT verbose ACTION If numerous link events are occurring check physical connections to the FC network REMARKS Ipfc_mes1304 is recorded if Map Entries gt 0 and the corresponding mode and SEVERITY level is set Ipfc_mes1305 1305 Link down even tag x x DESCRIPTION A link down event was rec
67. n ADISC response 0x55 Exhausted retries on ELS ADISC 0X59 Exhausted retries on ELS LOGO 0X5B Attempted ELS PRLI non existent node 0x5D Exhausted retries on ELS PRLI 0x63 Attempt to issue command to fabric without a valid fabric login 0x65 Error issuing fabric command Nameserver request status reported as ELS command error status aa with byte 0x11 aa The Appendix has more information see ELS Command Codes on page 64 Storport Miniport Driver User Manual Page 59 X EMULEX Table 8 Malfunction Errors Continued Bits 0 7 Interpretation 0x66 Invalid fabric command type Ox6A Invalid fabric command sub type 0Ox6C Name server response error CT command response bbaa with byte 0x11 aa byte 0x12 bb The Appendix has more information see CT Command Response Codes on page 63 0x6D Name server response error FC CT reject code aa with byte 0x11 aa The Appendix has more information see FC CT Reject Reason Codes on page 64 Ox6F SCN registration failed 0x71 Received unsupported ELS command code aa with byte 0x11 aa The Appendix has more information see ELS Command Codes on page 64 0x76 Invalid format for received PRLI 0x83 Node object allocation failure Ox9A SCSI command error reported with SCSI STATUS of cc on Target aa LUN bb with byte 0x11 aa byte 0x12 bb byte 0x13 cc For more information see SCSI Status on page 64 OxA2 Genera
68. n an adapter failed The reason and suggested corrective action are displayed 2 Perform the suggested corrective action and run AutoPilot Installer again Storport Miniport Driver User Manual Page 12 X EMULEX Performing an Unattended Installation An unattended installation sometimes referred to as a quiet or silent installation requires no user input This is useful for performing an installation remotely from a command script or when you want to make sure a custom configuration will not be changed by a user during installation There are several ways to perform an unattended installation These correspond to the options for running the software installation interactively Option 1 Automatically Run AutoPilot Installer Run the driver kit installer from a command prompt or script Specify the q quiet command line option For example storportminiportkit 2 20 06 exe q Note The name of the driver kit installer depends on whether you are installing the full or core package and the current version identifier For other command line options see Driver Kit Installer Command Line Parameters on page 14 Option 2 Run AutoPilot Installer Separately e Run the driver kit installer but defer running AutoPilot Installer Then choose one of the following options e Run AutoPilot Installer from a command prompt or script with the silent option APInstall exe silent e Edit the AutoPilot Installer configuration f
69. n needed informational Ipfc_mes0260 0260 Stop node timer on NPortld x x SCSIld x x DESCRIPTION Discontinuing timer for reconnected target with NPort ID and SCSI ID SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Storport Miniport Driver User Manual Page 47 X EMULEX Ipfc_mes0262 0262 Node timeout on NPortld x x SCSIld x x DESCRIPTION Disconnected NPort ID SCSI ID has failed to reconnect within timeout limit SEVERITY Error LOG LOG_ELS verbose ACTION Review system configuration Mailbox Log Messages 0310 0326 Ipfc_mes0310 0310 Mailbox command timeout HBA unresponsive DESCRIPTION A Mailbox command was posted to the adapter and did not complete within 30 seconds sync 0 asynchronous mailbox command is issued 1 synchronous mailbox command is issued SEVERITY Error LOG LOG_MBOX verbose ACTION This error could indicate a software driver or firmware problem If no I O is going through the adapter reboot the system If these problems persist report these errors to Technical Support Ipfc_mes0326 0326 Reset HBA HostStatus x x DESCRIPTION The adapter has been reset SEVERITY Information LOG LOG_MBOxX verbose ACTION No action needed informational INIT Log Messages 0400 0463 Ipfc_mes0400 0400 Initializing discovery module OptionFlags x x DESCRIPTION Driver discovery process is being initialized with internal flags as shown SEVERITY Info
70. nd error ulpStatus x x ulpWord 4 x x XRI x x ulpWord 7 x x DESCRIPTION The specified device failed an I O FCP command SEVERITY Warning LOG LOG_FCP verbose ACTION Check the state of the target in question REMARKS Ipfc_mes0730 is also recorded if it is a FCP Rsp error Storport Miniport Driver User Manual Page 50 X EMULEX Ipfc_mes0730 0730 FCP response error Flags x x SCSI status x x Residual d DESCRIPTION The FCP command failed with a response error SEVERITY Warning LOG LOG_FCP verbose ACTION Check the state of the target in question remark lpfc_mes0716 lpfc_mes0734 Ipfc_mes0736 or Ipfc_mes0737 is also recorded for more details if the corresponding SEVERITY level is set SEE ALSO Ipfc_mes0729 lpfc_mes0734 0734 Read Check fcp_parm x x Residual x x DESCRIPTION The issued FCP command returned a Read Check Error SEVERITY Warning LOG LOG_FCP verbose ACTION Check the state of the target in question SEE ALSO Ipfc_mes0730 Ipfc_mes0737 0737 SCSI check condition SenseKey x x ASC x x ASCQ x x SrbStatus X X DESCRIPTION The issued FCP command resulted in a Check Condition SEVERITY Warning LOG LOG_FCP verbose ACTION Review SCSI error code values SEE ALSO Ipfc_mes0730 0747 Target reset complete Pathld x x Targetld x x Did x x DESCRIPTION A target reset operation has completed SEVERITY Warning LOG LOG_FCP verbose ACTION Review system configuratio
71. nfigure ring 0 failed Ox0E Configure ring 1 failed OxOF Configure ring 2 failed 0x10 Configure ring 3 failed 0x11 Initialize link failed 0x12 Port ready failed 0x13 Read revision failed 0x14 Invalid adapter type 0x15 Invalid adapter type 0x17 Set variable command failed 0x18 Configure port failed 0x19 Configure ring 0 failed 0x1A Configure ring 1 failed 0x1B Configure ring 2 failed 0x1C Configure ring 3 failed 0x1E Context pool initialization failure 0x1F Context pool initialization failure 0x20 Context pool initialization failure 0x24 Firmware trap fatal adapter error Contact Emulex Technical Support If HBAnyware is installed check for FW dump in C Program Files Emulex Util Dump 0x25 Non specific fatal adapter error FW error attention information ccbbaa will be posted with byte 0x11 aa byte 0x12 bb byte 0x13 cc contact Emulex Technical Support 0x27 FCoE chip is running Golden firmware 0x28 FCoE chip is running Diagnostic firmware 0x29 Recoverable adapter error device has been auto restarted 0x2A Mailbox command time out Storport Miniport Driver User Manual Page 57 X EMULEX Table 7 Severe Errors Continued Bits 0 7 Interpretation 0x2B Invalid FRU data found on adapter contact Blade Vendor for procedure to reinstall firmware on Emulex Mezzanine Card 0x2D Inva
72. ng Diagnostics Note The DiagEnable parameter cannot be specified on the command line Default True By default AutoPilot Installer will run its diagnostics after all driver installation tasks have been completed To disable this function set this parameter to false ForceDriverTypeChange Forcing a Driver Type Change Default False When installing a driver set this parameter to true to cause silent mode installations to update install the Storport Miniport driver on each adapter in the system without regard for the currently installed driver type replacing any installation of the SCSlport Miniport or FC Port driver ForceDriverUpdate Forcing a Driver Version Update Default False By default if the same version of the driver is already installed an unattended installation will proceed with installing only the utilities To force a driver update even if the same version of the driver is installed set this parameter to true Note ForceDriverUpdate applies to unattended installations only in interactive installations this parameter is ignored Instead you are asked if the driver should be updated ForceRegUpdate Forcing Updates of an Existing Driver Parameter Value Default False The ForceRegUpdate driver parameter setting determines if existing driver parameters are retained or changed when you update the driver By default all existing driver parameter settings are retained The ForceRegUpdate paramet
73. nstallation has completed The HBAnyware utility automatically starts running To install the core utility set 1 cd to the Core folder in the Utilities folder 2 Run setupCLl exe 3 Click Finish in the Finish page to exit setup The core installation has completed Storport Miniport Driver User Manual Page 29 X EMULEX HBAnyware Security Configurator Installing the HBAnyware Security Configurator After the HBAnyware utility and remote server are installed on a group of systems the utility can remotely access and manage the Emulex adapters on any systems in the group This may not be desirable because any system with remote access can perform actions such as resetting boards or downloading firmware The HBAnyware Security Configurator controls which HBAnyware systems can remotely access and manage adapters on other systems in a Storage Area Network SAN HBAnyware security is system based not user based As a result anyone who can access a system with HBAnyware client access to remote adapters can manage those adapters The Emulex driver and the HBAnyware utilities must be installed before you can install the HBAnyware Security Configurator To install the HBAnyware Security Configurator 1 Locate the SSCsetup exe file The default path for this file is C Program Files Util HBAnyware Double click the SSCsetup exe file A welcome page appears Click Next The Setup Status window is displayed After setup completes the Emulex
74. nstaller to complete before it continues The preferred method for launching the driver kit Installer from a command prompt or a command script is start wait storportminiportkit_2 20 006 Running a Software Installation Interactively There are three options when performing an installation interactively These options assume you have already downloaded the driver kit installer from the Emulex web site Option 1 Automatically Run AutoPilot Installer Use this option unless you have specific configuration needs This option allows you to complete a driver kit installation and AutoPilot installation with a few simple mouse clicks 1 Double click the driver kit installer or run it from a command line See Driver Kit Installer Command Line Parameters on page 14 for information on the command line options One command line parameter APargs lets you specify arguments that will automatically be passed to the AutoPilot Installer command A Welcome page is displayed with driver kit version information and Emulex contact information 2 Click Next to proceed to the Installation Options page For each installation option the default installation location for that option is displayed Browse to a different location if desired e For the core driver kit there is only one installation option Perform AutoPilot Installation For the full driver kit you have an additional option to Create AutoPilot Installer Kits The default option is Pe
75. on Identification AUTOPILOT ID This section contains revision and label information The revision entry identifies the file s version number and the date on which it was produced The label entry is used to identify the configuration that the file supports This section may appear only once in the APInstall cfg file Software Configuration AUTOPILOT CONFIG The settings in this section affect the operation of AutoPilot Installer during installation They also affect the operation of the HBAnyware utilities after they are installed See Software Configuration Parameters on page 17 for information about settings that may be specified in this section Configuration Prompts Vendor Specific Questions STORPORT CONFIGURATION Note You must remove or comment out the entire STORPORT CONFIGURATION section for an unattended installation A STORPORT CONFIGURATION section may exist in the AutoPilot Configuration file The first items in this section are the driver parameters to be used regardless of how the questions are answered This is followed by a subsection that contains questions these may be vendor specific questions A line containing QUESTIONS marks the start of the subsection and the end of it is marked by a line containing ENDQUESTIONS Within the question subsection there can be as many questions as needed Each question uses the format question question explanation answer0O answerl answer2
76. or FC Port driver an Available Drivers list will be displayed for your review Click OK on this window e Ifyou are updating the driver and the utility your existing management modes and port settings will be used unless otherwise specified in the configuration file These settings will be pre selected but can be changed Set or change settings then click Next e Ifyou are initially installing a vendor specific version of the Emulex driver installation program a Driver Configuration page may be displayed This page includes one or more windows with questions that you must answer before continuing the installation process In this case answer each question and click Next on each window to continue 4 Ifthe Utilities Installation page appears as seen in Figure 1 select how adapters local and remote are managed by the HBAnyware utility Note The display of the Utilities Installation page is optional and based on settings on the AutoPilot Installer command line or in the AutoPilot Configuration file See Software Configuration Parameters on page 17 for more information The following configurations can be selected e Strictly Local Management The HBAnyware utility only manages the adapters on this host and no remote management of adapters is allowed e Local Management Plus The HBAnyware utility only manages the adapters on this host Management of adapters on this host from other hosts is allowed e Full Management
77. or of some problem with interaction between the HBA the Emulex Storport Miniport driver the host operating system and the host memory Note Context allocation failures are rare Storport Miniport Driver User Manual Page 66
78. ormational Ipfc_mes0129 0129 Rejected ELS command OpCode x x DESCRIPTION Rejected ELS command from a remote NPORT SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational lpfc_mes0130 0130 ELS command error ulpStatus x x ulpWord 4 x x DESCRIPTION ELS command failure SEVERITY Error LOG LOG_ELS verbose ACTION Check remote NPORT for potential problem Discovery Log Messages 0202 0262 Ipfc_mes0202 0202 Start Discovery Link Down Timeout x x initial PLOGICount d DESCRIPTION Device discovery rediscovery after FLOGI FAN or RSCN has started TMO is the current value of the soft link time It is used for link discovery against the LinkDownTime set in parameters DISC CNT is number of nodes being discovered for link discovery RSCN CNT is number of nodes being discovered for RSCN discovery There will be value in either DISC CNT or RSCN CNT depending which discovery is being performed SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Storport Miniport Driver User Manual Page 45 X EMULEX Ipfc_mes0204 0204 Discovered SCSI Target WWN word 0 x x WWN word 1 x x DID X x RPI x x DESCRIPTION Device discovery found SCSI target SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Ipfc_mes0214 0214 RSCN received Word count d DESCRIPTION Received RSCN from fabric SEVERITY Informatio
79. ports installed in your system 1 Run the driver kit installer but do not run AutoPilot Installer See Running a Software Installation Interactively on page 6 for instructions on how to do this 2 Select Start gt Control Panel gt Add Hardware The Add Hardware Wizard window appears Click Next 3 Select Yes have already connected the hardware and click Next 4 Select Add a new hardware device and click Next 5 Select Install the hardware that manually select from a list Advanced and click Next 6 Select Show All Devices and click Next 7 Click Have Disk Direct the Device Wizard to the location of elxplus inf If you have installed the driver installer kit in the default folder and C is your Windows system drive the path is C Program Files Emulex AutoPilot Installer Drivers Storport x86 HBA for the 32 bit driver version or C Program Files Emulex AutoPilot Installer Drivers Storport x64 HBA for the x64 driver version or C Program Files Emulex AutoPilot Installer Drivers Storport IA64 HBA for the Itanium driver version 8 Click OK 9 Select Emulex PLUS Click Next and click Next again to install the driver 10 Click Finish The initial ElxPlus driver installation is complete Continue with manual installation of the Storport Miniport Driver See page 28 for this procedure Storport Miniport Driver User Manual Page 27 X EMULEX Manually Updating the Emulex PLUS ElxPlus Driver To update
80. r kit If desired customize the APInstall cfg file It is located in the Installers folder within the folder created by the driver kit See AutoPilot Configuration File on page 20 for more information 4 Decide whether you want AutoPilot Installer to install the full utilities kit including the HBAnyware GUI and CLI or just the core utilities kit no GUI Note The GUI cannot be installed on Server Core systems 5 Decide which CPU architectures on which you ll install the kits x86 x64 or IA64 6 Run the makekit command script in the folder created by the driver kit makekit The makekit script will prompt you for the CPU architecture and utilities set If you prefer you may run makekit non interactively from a command prompt or a command script To see all the makekit options type makekit For example to create a kit folder for x86 machines that installs the full utility set you can type makekit x86 full Unless you specify a different path on the makekit command makekit will create a folder in the current folder by concatenating the architecture and utilities options chosen For example x86 full kit Note Since makekit is a command script you must precede it with the Windows call command to call it from another command script Otherwise the parent script will not continue after the makekit script exits For example REM Create kit for Windows Server 2008 x64 Core installations call makekit x64 cor
81. rform AutoPilot Installation only 3 Click Install to continue the installation The Progress dialog box is displayed After all tasks complete a Finish page is displayed The Start AutoPilot Installer box is automatically selected 4 Click Finish AutoPilot Installer is run automatically Option 2 Run AutoPilot Installer Separately This option is recommended to e Change installation settings such as the HBAnyware management mode for a limited number of systems e Familiarize yourself with AutoPilot Installer configuration options e Test a configuration file that you created as part of Option 3 see below To access these features you run AutoPilot Installer after driver kit installation is done This allows you to change the configuration options supplied to AutoPilot Installer see below 1 Perform steps 1 through 3 for Option 1 2 Clear the Run AutoPilot Installer check box on the Finish page 3 Click Finish The driver kit installer exits Storport Miniport Driver User Manual Page 6 X EMULEX After the driver kit installation is finished change the configuration in one of two ways e Change the configuration file See Software Configuration Parameters on page 17 for details e Supply parameters on the command line See Command Line Parameter Settings on page 16 for details Once you have finished this step you can run AutoPilot Installer at a later time using either of the following methods If
82. rmation Create an AutoPilot Installer kit that can be customized and used to run AutoPilot Installer on your system or another system See page 7 for more information Note The third option is only available when installing the full driver kit While the full driver kit cannot be installed on Server Core systems it can be used to create AutoPilot Installer Kits for those systems Storport Miniport Driver User Manual Page 3 X EMULEX Files Installed by the Driver Kit Installer The driver kit installer copies the AutoPilot Installer Files to your system By default the files necessary to run AutoPilot Installer are copied to c Pro gram Files Emulex AutoPilot Installer When you select the Create AutoPilot Installer Kits option the files are copied by default to an Emulex folder in your Documents folder Table 1 AutoPilot Installer Program Files Folder Description AutoPilot Installer This folder contains files necessary to run the AutoPilot Installer including e APInstall exe Executable file for the AutoPilot Installer e APInstall cfg Default configuration file for the AutoPilot Installer Drivers Storport This folder contains the files necessary to install the drivers Utilities This folder contains files necessary to install the HBAnyware utilities reports AutoPilot Installer reports are placed here by default Reports can be placed in a different location using the ReportLocation parameter
83. rmation LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0401 0401 Initializing SLI module Deviceld x x NumMSI d DESCRIPTION PCI function with device id and MSI count as shown is being initialized for service level interface SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0405 Service Level Interface SLI 2 selected n DESCRIPTION Service Level Interface level 2 is selected SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0406 0406 Service Level Interface SLI 3 selected n DESCRIPTION Service Level Interface level 3 is selected SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Storport Miniport Driver User Manual Page 48 X EMULEX Ipfc_mes0436 Adapter not ready hostStatus x x DESCRIPTION The adapter failed during powerup diagnostics after it was reset SEVERITY Error LOG LOG_INIT verbose ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0442 0442 Adapter failed to init CONFIG PORT mbxStatus x x DESCRIPTION Adapter initialization failed when issuing CONFIG_PORT mailbox command SEVERITY Error LOG LOG_INIT verbose ACTION This error could indicate a hardware or firmware problem If problems persist report these errors to Technical Support Ipfc_mes0
84. rt SEVERITY Error LOG LOG_NPIV verbose ACTION Check to ensure system has sufficient kernel memory Ipfc_mes1802 1802 Exceeded the MAX NPIV port x x DESCRIPTION Exceeded the number of Virtual Port allows on the HBA SEVERITY Error LOG LOG_NPIV verbose ACTION Reduce the number of Virtual Ports Ipfc_mes1803 1803 Virtual Port x x VPI x x successfully created DESCRIPTION Virtual Port ID is successfully created SEVERITY Information LOG LOG_NPIV verbose ACTION No action needed informational Ipfc_mes1804 1804 Removing Virtual Port x x VPI x x DESCRIPTION Removing Virtual Port ID SEVERITY Information LOG LOG_NPIV verbose ACTION No action needed informational ELS Messages 1900 1999 1900 x x sends ELS_AUTH_CMD x x with TID x x DESCRIPTION An ELS_AUTH_CMD is sent SEVERITY Information LOG LOG_FCSP verbose ACTION No action needed informational 1901 x x sends ELS_AUTH_REJECT x x x x to x x DESCRIPTION An ELS _AUTH_REJECT is sent SEVERITY Information LOG LOG_FCSP verbose ACTION No action needed informational Storport Miniport Driver User Manual Page 53 X EMULEX 1902 Receives x x from x x in state x x DESCRIPTION Receives an ELS_AUTH_CMD SEVERITY Information LOG LOG_FCSP verbose ACTION No action needed informational 1903 Receives ELS_AUTH_RJT x x x x DESCRIPTION Receives an ELS AUTH REJECT SEVERITY Information LOG LOG_FCSP verbose ACTION No a
85. s 0011 through 0013 Additional Event Log Information The following tables are not comprehensive but do include those codes which through Emulex s experiences in our support and testing environments we feel are most likely to show up in SAN environments where problems occur ELS FCP Command Error Status Codes Internal firmware codes posted by the HBA firmware that explain why a particular ELS or FCP command failed at the Fibre Channel level Table 11 ELS FCP Command Error Status Codes Explanation Code Remote Stop Remote port sent an ABTS 0x2 Local Reject Local Reject error detail 0x3 LS_RJT Received Remote port sent LS_RJT 0x9 A_RJT Received Remote port sent BA_RJT OxA CT Command Response Codes Codes that indicate the response to a Fibre Channel Common Transport protocol command Table 12 CT Command Response Codes Explanation Code FC Common Transport Reject 0x8001 FC Common Transport Accept 0x8002 Storport Miniport Driver User Manual Page 63 FC CT Reject Reason Codes Codes that indicate the reason a CT command was rejected Table 13 FC CT Reject Reason Codes X EMULEX Explanation Code Invalid command code 0x01 Invalid version level 0x02 Logical busy 0x05 Protocol error 0x07 ELS Command Codes Fibre Channel protocol codes that describe what particular Extended Link Services command was sent Table 14 ELS Command Co
86. se configuration file parameters to determine the appropriate management mode ManagementPort Specifying the Port Number Note The ManagementPort parameter cannot be specified on the command line Default 23333 assigned to Emulex by the Internet Assigned Numbers Authority IANA A numeric value indicating the port number at which Emulex utilities should operate If changed this setting must be propagated throughout any other machines on the SAN ReportLocation Setting Up an Installation Report Title and Location The automatically generated file name for reports is report_mm dd yy txt where mm is the month number dd is the day and yy indicates the year You can only change the installation report folder the file name is auto generated In the following example x could be any available drive ReportLocation x autopilot reports installs SilentInstallEnable Enabling Unattended Installation Note Setting the SilentInstallEnable parameter to true in the configuration file is functionally equivalent to supplying the silent switch on the command line You cannot specify the SilentInstallEnable parameter on the command line Default False Setting this parameter to true causes AutoPilot Installer to operate with no user interaction Storport Miniport Driver User Manual Page 19 X EMULEX SilentRebootEnable Enabling Silent Reboot Default False If Windows must be restarted
87. systems b cd to Emulex AutoPilot Installer c Run uninstall_elx_core_kit bat The installer files are removed from the system On all platforms the reports folder in the Emulex AutoPilot Installer folder is not removed so you can still view installation history and see which drivers have been installed on the system You may delete the reports folder at any time if you want Storport Miniport Driver User Manual Page 33 X EMULEX Uninstalling the Emulex Drivers The Emulex Storport Miniport and PLUS ElxPlus drivers are uninstalled using the Device Manager To uninstall the Emulex Storport Miniport driver 1 Select Start gt All Programs gt Administrative Tools gt Computer Management 2 Click Device Manager 3 Double click the adapter from which you want to remove the Storport Miniport driver A device specific console window is displayed Select the Driver tab 4 Click Uninstall and click OK to uninstall To uninstall the ElxPlus driver uninstall the ElxPlus driver only if all adapters and installations of Emulex miniport drivers are uninstalled After running Device Manager steps 1 and 2 above 1 Click the plus sign next to the Emulex PLUS driver class 2 Right click the Emulex driver and click Uninstall 3 Click OK in the Confirm Device Removal window To uninstall or update an earlier version of the Storport Miniport driver prior to version 1 20 you must remove the registry settings for t
88. t SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0105 0105 LOGO completes to NPortld x x DESCRIPTION The adapter performed a LOGO into a remote NPort SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Ipfc_mes0112 0112 ELS command x x received from NPortld x x DESCRIPTION Received the specific ELS command from a remote NPort SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational REMARKS Ipfc_mes0114 and Ipfc_mes0115 are also recorded for more details if the corresponding SEVERITY level is set You can use the XRI to match the messages Storport Miniport Driver User Manual Page 44 X EMULEX Ipfc_mes0114 0114 PLOGI chkparm OK DESCRIPTION Received a PLOGI from a remote NPORT and its FC service parameters match this adapter Request can be accepted SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational SEE ALSO Ipfc_mes0112 Ipfc_mes0115 0115 Unknown ELS command x x received from NPortld x x n DESCRIPTION Received an unsupported ELS command from a remote NPORT SEVERITY Error LOG LOG_ELS verbose ACTION Check remote NPORT for potential problem SEE ALSO Ipfc_mes0112 Ipfc_mes0128 0128 Accepted ELS command OpCode x x DESCRIPTION Accepted ELS command from a remote NPORT SEVERITY Information LOG LOG_ELS verbose ACTION No action needed inf
89. t Value 0 1 or 0x0 0x1 hex Default 0 0x0 RmaDepth n RmaDepth sets the remote management buffer queue depth The Reboot greater the depth the more concurrent management controls can be handled by the local node Value 8 64 or 0x8 0x40 hex Default 16 0x10 Note The RmaDepth driver parameter pertains to the functionality of the HBAnyware utility ScanDown n If set to 0 lowest AL_PA lowest physical disk ascending AL_PA Reboot order If set to 1 highest AL_PA lowest physical disk ascending SEL_ID order Value 0 1 Default 0 Note This option applies to private loop only in DID mode SLIMode n If set to 0 autoselect firmware use the newest firmware installed Reboot If set to 2 implies running the HBA firmware in SLI 2 mode If set to 3 implies running the HBA firmware in SLI 3 mode Value 0 2 and 3 Default 0 Topology n Topology values can be 0 to 3 Reset If set to 0 0x0 FC Arbitrated Loop FC AL If set to 1 0x1 PT PT fabric If set to 2 0x2 FC AL first then attempt PT PT If set to 3 0x3 PT PT fabric first then attempt FC AL Topology fail over requires v3 20 firmware or higher If firmware does not support topology fail over options 0 2 and 1 3 are analogous Value 0 3 Default 2 0x2 Storport Miniport Driver User Manual Page 41 X EMULEX Table 5 Storport Miniport Driver Parameters Continued Parameter Definitions Activation
90. t to 0 or leave the default value Test Scenario Two You execute IOMETER with an I O depth of 48 I Os per device in a small scale configuration 16 devices Recommendation set QueueDepth to be greater than 48 e g 64 Storport Miniport Driver User Manual Page 36 X EMULEX Driver Parameters for Windows The parameter values listed in Table 5 are applicable to Storport Miniport driver versions 2 20 or later If you are using a version previous to 2 20 see the Storport Miniport Driver User Manual for that version s parameter information Activation Requirements A parameter has one of the following activation requirements e Dynamic The change takes effect while the system is running e Reset Requires an adapter reset from the utility before the change takes effect e Reboot Requires reboot of the entire machine before the change takes effect In this case you are prompted to perform a reboot when you exit the utility The Driver Parameter table provides information such as the allowable range of values and factory defaults Parameters can be entered in decimal or hexadecimal format Note If you are creating custom unattended installation scripts any driver parameter can be modified and included in the script Most parameters default to a setting that optimizes adapter performance Table 5 Storport Miniport Driver Parameters Parameter Definitions Activation Requirement AutoMap n AutoMap controls th
91. teeeees 14 Configuring an AutoPilot Installer Kit 0 0 0 0 cece eeeeeeeeeeeeeeeeeeeeeeeeeeeaeaaaaaaaaaaaaaeeeeeees 15 AutoPilot Installer Command Line Parameters ceeeeeeeeeeeeeeeeeeeeeeeaes 16 Command Line Parameter Settings eee eee 16 Configuration File Location 0 0 0 0 ieee 17 Software Configuration Parameters 0 0 00 ti erie 17 AutoPilot Configuration File cccecccccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeneeteeeenes 20 Configuration Identification AUTOPILOT ID cceeeeeeeeeeeeteeeeeeetees 21 Software Configuration AUTOPILOT CONFIG eeeeeeeeeeeeeteeeees 21 Configuration Prompts Vendor Specific Questions S TORPORT CONFIGURATION rrisin 21 QFE Checks STORPORT QFES unia 23 Setting Up Driver Parameters STORPORT PARAMS 2 cee eeeeees 23 Setting Up System Parameters SYSTEM PARAMS ccceceeeeeees 23 AutoPilot Installer Exit Codes cccccccccceeeeeeeeeeeceeeeeeeeeeeeeeeeaaaeeeeeeeeeeesaaaaeees 24 AutoPilot Installer Installation Reports ccceeecccceeeeeeeeeeeeeeeeeeeeeeeeees 25 Command Script Example cccceeee cee eeeeeeeeeeeeeeeaeaeeeeeeeeeeesaaaaeeeeeeees 25 Manual Installation and Updating Procedures ccccccceeceeeeeeeeeeeeeteeeeeeeeeeeeeeeees 27 Manually Installing or Updating the Storport Miniport Driver cee 27 Manually Installing the Emulex PLUS ElxPlus Dr
92. termines the minimum severity level to enable entry of a logged error into the system e If set to 0 all errors regardless of severity are logged e If set to 1 severe malfunction and command level errors are logged e If set to 2 both severe and malfunction errors are logged e If set to 3 only severe errors are logged Note See the Configuration Section for instructions on how to set driver parameters Note Set LogError to 1 if you are troubleshooting SAN connectivity or device discovery issues Format of an Error Log Entry An error log entry will take the form of an event This event is described by e Date date entry was logged e Source elxstor Time time entry was logged e Category none e Type error e Event d D e User N A e Computer name of computer Storport Miniport Driver User Manual Page 56 Error Codes Tables Table 7 Severe Errors X EMULEX Bits 0 7 Interpretation 0x00 Failed to allocate PCB 0x01 Failed to allocate command ring 0x02 Failed to allocate response ring 0x03 Failed to allocate mailbox context 0x04 Read revision failed 0x05 Invalid adapter type 0x06 Invalid adapter type 0x07 Write of non volatile parameters failed 0x08 Invalid link speed selection 0x09 Read configuration failed 0x0A Set variable failed 0x0B Configure port failed 0x0D Co
93. the driver to the operating system based upon response from SCSI device in the SAN Table 17 SRB Status Codes Explanation Code ERROR 0x04 BUSY 0x05 TIMEOUT 0x09 SELECTION TIMEOUT Ox0A COMMAND TIMEOUT 0x0B BUS RESET 0x0E DATA OVERUN 0x12 ASC ASCQ Additional Sense Code Additional Sense Code Qualifier information can be found in any SCSI specification document these codes contain detailed information about the status condition of the SCSI device in question Storport Miniport Driver User Manual Page 65 X EMULEX Additional Notes on Selected Error Codes These are error codes which may be seen more frequently than others or which indicate conditions that you might be able to solve by investigation and correction of problems in the SAN configuration Note Nomenclature of 0x is used as the prefix for the byte code fields since those byte codes are actually hex values Node timeout code 0xAA This event code indicates that a particular device has not been found if the message is logged during device discovery or that a particular device has been removed from the fabric If this message is seen determine if there is something wrong with the connection of that device to the SAN cables switches or switch ports status of the target device itself SCSI Command Error Ox9A and SCSI Check Condition code 0x9B Code Ox9A indicates that the SCSI command to a particular device was
94. to Dynamic start port discovery after link up If set to 0 immediate discovery after link up If set to 1 or 2 the number of seconds to wait after link up before starting port discovery Value 0 2 seconds decimal Default 0 EnableAck0O n Set to 1 to force sequence rather than frame level acknowledgement Reset for class 2 traffic over an exchange This applies to FCP data exchanges on IREAD and IWRITE commands Value 0 1 decimal Default 0 EnableAUTH EnableAUTH enables fabric authentication This feature requires the Reboot authentication to be supported by the fabric Authentication is enabled when this value is set to 1 Value 0 1 Default 0 EnableFDMI n If set to 1 enables management server login on fabric discovery This Reset allows Fabric Device Management Interface FDMI to operate on switches that have FDMI capable firmware If set to 2 FDMI operates and uses the host name feature of FDMI Value 0 2 decimal Default 0 EnableNPIV n If set to 1 enables N_Port_ID virtualization NPIV Requires NPIV Reset supported firmware for the adapter Value 0 1 Default 0 disabled Note To run the driver using NPIV or SLI 3 optimization the firmware must be version 2 72a0 or later If an earlier version is used the driver runs in SLI 2 mode and does not support NPIV Note NPIV is not available on 1Gb s and 2 Gb s HBAs Storport Miniport Driver User Manual Page 38 X EMULEX Table 5 Storport
95. uninstallation The batch file is typically in C Program Files Emulex Util Uninstall For HBAnyweare it is uninstall_ HBAnyware bat For HBAnyware CLI it is uninstall HBAnyware_CLI bat For Emulex Common SAN Management it is uninstall_CommonSAN bat 5 At this point you can reinstall the utilities by running AutoPilot Installer To remove AutoPilot Installer a Select Emulex Storport Miniport Driver Kit or Emulex Storport Miniport Driver Core Kit b Click the Uninstall icon If you have User Access Control enabled click Continue when asked for permission c Click Yes The installer files are removed from the system Click OK To uninstall the HBAnyware utilities and AutoPilot Installer on a Server Core system 1 cd to the Program Files folder on an x86 system or the Program Files x86 folder on a 64 bit system cd to Emulex Util Uninstall Run uninstall HBAnyware_CLI bat You may now delete the Emulex Util folder You may also delete the Emulex folder if it is now empty Note Running the ininstall_HBAnyware_CLI bat command may display the following error message Uninstaller exited with code 0 The batch file cannot be found Disregard this error message if it displays as all the program files required to be removed are in fact removed 4 To remove AutoPilot Installer continue with the following steps a cd to the Program Files folder on both x86 systems and 64 bit
96. unning on an x86 x64 or Itanium server e Server Core installation option of Windows Server 2008 running on an x86 or x64 server e Windows Vista SP1 running on an x86 or x64 platform e Minimum 512 MB memory e See the Emulex Web site for required updates to the Microsoft Storport driver Compatibility e The Emulex Storport Miniport driver is compatible with the following Emulex adapters e LP21002 and LP21000 converged network adapters CNAs minimum firmware version 1 00a4 Note The LP21002 and LP21000 CNAs do not support Windows Server 2003 2008 on Itanium servers e LPe12002 LPe12000 and LPe1250 adapters minimum firmware version 1 00a9 e LPe11004 LPe11002 LPe11000 and LPe1150 adapters minimum firmware version 2 72a2 e LP11002 LP11000 and LP1150 adapters minimum firmware version 2 72a2 Storport Miniport Driver User Manual Page 2 X EMULEX e LP10000DC LP10000 LP1050DC and LP1050 adapters minimum firmware version 1 91a5 e LP10000ExDC and LP1050Ex adapters minimum firmware 1 91a5 e LP9802DC LP9802 and LP982 adapters minimum firmware version 1 91a5 e LP9402DC LP9002DC LP9002L LP9000 amp LP952L adapters minimum firmware version 3 93a0 x86 BootBIOS LP21002 and LP21000 minimum version 2 02a1 LPe12002 LPe12000 and LPe1250 minimum version 2 01a2 all other adapter models minimum version 1 71a0 EFIBoot L_P21002 and LP21000 are not supported LPe12002 LPe12000 and LPe1250 minimum version 4 00a1
97. utomatically load when you install the adapters Utility Only update If the Storport Miniport driver in the driver kit is the same version as what is already installed on the system you can reinstall or update the previously installed utility without reinstalling the Storport Miniport driver Text Only installation Text based installation mode is used automatically when AutoPilot Installer is run on a Server Core system Network installation You can place the driver kit installers on a shared network drive and install them across your local area network LAN You can use the full driver kit to create your own AutoPilot Installer kits for network based installation Network based installation is often used in conjunction with unattended installation and scripting This allows you to configure and install the same driver and utility versions on all the hosts in a SAN Unattended installation You can run the driver kit installers and AutoPilot Installer with no user interaction from a command line or script Unattended installation works for both hardware first and software first installations and with both the full driver kit and the core driver kit An unattended installation operates in silent mode sometimes referred to as quiet mode and creates an extensive report file with installation status Storport Miniport Driver User Manual Page 1 X EMULEX Important Considerations New in This Release e ExtTransferSize parameter has been ad
98. ve installed the driver installer kit to the default folder the path is C Program Files Emulex AutoPilot Installer Drivers Storport x86 HBA for the 32 bit driver version or C Program Files Emulex AutoPilot Installer Drivers Storport x64 HBA for the x64 driver version or C Program Files Emulex AutoPilot Installer Drivers Storport IA64 HBA for the Itanium driver version 12 Click OK Select Emulex LightPulse LPX000 PCI Slot X Storport Miniport Driver your adapter model will be displayed here 13 Click Next 14 Click Finish The driver installation is complete The driver should start automatically If the adapter is connected to a SAN or data storage device a blinking yellow light on the back of the HBA will indicate a link up condition Manually Installing the Driver Utilities Run the full driver kit installer Select the Create AutoPilot Installer Kit option clear the Perform AutoPilot Installation option and click Next After the files have been copied to your system the Finish page will show where the files have been placed Click Finish A Utilities folder will exist in the folder created by the installer To install the full utility set including the HBAnyware utility GUI 1 Run SetupCommon exe 2 Run Setup exe Caution Run Setup exe only after running SetupCommon exe 3 Follow the instructions on the setup windows 4 Click Finish in the Finish page to exit setup The utility i
99. ver kit may be installed on any system The driver kit installer is an executable file with a name similar to storportminiportkit_2 20 006 exe for the full driver kit or storportminiportcorekit_2 20 006 exe for the core driver kit Note The name of the driver kit installer depends on the current version identifier 2 Once you download the driver kit installer you have several options e Foran automatic interactive installation without customization see Option 1 Automatically Run AutoPilot Installer on page 6 e For control of all interactive installation settings see Option 2 Run AutoPilot Installer Separately on page 6 e To create your own AutoPilot Installer kits and deploy them see Option 3 Create an AutoPilot Installer Kit on page 7 e Foran unattended installation with AutoPilot Installer see Performing an Unattended Installation on page 13 Storport Miniport Driver User Manual Page 5 X EMULEX Starting Installers from a Command Prompt or Script When a driver kit installer or AutoPilot Installer is run from a command prompt or command script batch file the Windows command processor does not wait for the installer to run to completion Thus you cannot check the exit code of the installer before the next command is executed Emulex recommends that command line invocation always use the start command with the wait option This will cause the command processor to wait for the i
100. xPlus driver update is complete Continue with manual installation of the Storport Miniport Driver Manually Installing or Updating the Fibre Channel Storport Miniport Driver To update or install the Storport Miniport driver from the desktop 1 ak WN Select Start gt Control Panel gt System Select the Hardware tab Click Device Manager Open the SCSI and RAID Controllers item Double click the desired Emulex adapter Note The driver will affect only the selected adapter If there are other adapters in the system you must repeat this process for each adapter All DC adapter models will be displayed in Device Manager as two adapters therefore each adapter must be updated Select the Driver tab Click Update Driver The Update Driver wizard starts Select No not this time Click Next on the Welcome to the Hardware Update Wizard window Storport Miniport Driver User Manual Page 28 X EMULEX 9 Select Install from a list or specific location Advanced and click Next 10 Select Don t search I will choose the driver to install and click Next Note Using the OEMSETUP INF file to update Emulex s Storport Miniport driver overwrites customized driver settings If you are upgrading from a previous installation write down the settings Following installation use the HBAnyware utility to restore the pre upgrade settings 11 Click Have Disk Direct the Device Wizard to the location of oemsetup inf If you ha
101. you are supplying options via the command line you must use the second option e Select Programs gt Emulex gt AutoPilot Installer in the Start menu e Run AutoPilot Installer from a command line by running C Program Files Emulex AutoPilot Installer APInstall exe Note The location of APInstaller exe may differ on your system depending on your system s Program Files location You may also specify a different location when you install the driver package Option 3 Create an AutoPilot Installer Kit This option is recommended to install the same customized configuration on multiple systems in your SAN 1 Run the driver kit installer The Installation options page is displayed 2 Select the Create AutoPilot Installer Kits option 3 Clear the Perform AutoPilot Installation option unless you also want to run AutoPilot Installer using Option 1 or Option 2 as previously described The Create AutoPilot Installer Kits option will not install any additional programs on your system Instead files will be copied to a Documents folder The files can be used to create AutoPilot Installer Kits An AutoPilot Installer Kit is a folder containing APiInstall exe and other files You run this copy of APInstall exe from the command line After the driver kit installer is finished you ll typically find APInstall cfg in Documents Emulex AutoPilot Installer Kit version Installers where Documents is your Documents folder named My Documents
102. yte 0x13 cc OxE8 Received Authentication Reject Restart Virtual Port index ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc OxE9 Received Authentication Negotiate Virtual Port index ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc Storport Miniport Driver User Manual Page 61 S EMULEX Table 10 Event Indications OxEA Authenticating spurious traffic Virtual Port index ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc OxEB Authentication policy has been changed Virtual Port index ccbbaa with byte 0x11 aa byte 0x12 bb byte 0x13 cc Storport Miniport Driver User Manual Page 62 X EMULEX Appendix Supplemental Event Log Information The following information is designed to provide additional information that you might find useful in assisting your customers Event Log Interpretation e All events logged by Emulex Storport Miniport are in Event ID 11 with source elxstor e The Storport Miniport driver parameter LogErrors determines what type of events are logged by the driver the default setting is 3 which logs only events of a SEVERE nature the optional setting of 2 logs events of both SEVERE and MALFUNCTION type the optional setting of 1 logs events of SEVERE MALFUNCTION and COMMAND type Note For troubleshooting SAN connectivity or device discovery issues set the LogErrors to 1 e The Emulex event code is found in byte 0010 and supplementary data is in byte offset