1. RANGE INDICATOR SYSTEM Sleep Mode After 4 seconds the backlight LCD display and temperature range indicator turn off and the thermometer powers down GETTING TO KNOW Carrying and Storage If accessory is included To insert the ARC InstaTemp into the neoprene carrying case 1 Pull the hood of the case back 2 Remove the device by holding it on its sides and slide it into the case such that the LCD screen is slightly visible Do not touch the sensor 3 Cover with the hood and store in a dry place To remove the ARC InstaTemp from the neoprene carrying case Pull the hood of the neoprene case back Grab the ARC InstaTemp on its sides and pull out of the case GETTING TO KNOW Wall Mount If accessory is included The wall mount can be attached to any smooth vertical surface using its adhesive pad on the rear of the wall mount Because it is magnetic the wall mount can also be attached to any metal surface The internal magnet also keeps the ARC InstaTemp gently attached to the wall mount z D oO 5 3 2 3 3 2 TROUBLESHOOTING CN A This indicates an invalid reading This is due to incorrect usage such as trying to measure a temperature above or below the thermometers operating range or also due to a indeterminate reading Repeat the temperature measurement as described in the section titled TAKING A TEMPERATURE TROUBLESHOOTING An Er me
2. commencing operation Temperature Range Indicator Light Activation Button Internal non removable non replaceable batteries are included GETTING TO KNOW The ARC InstaTemp Features Quick and accurate body temperature measurement LCD screen with backlight for ease of use in the dark Temperature shown in either Fahrenheit F or Celsius C The temperature reading will be displayed on screen for 4 seconds Turns off automatically when not in use Fast temperature readings that meet the ASTM standard LED display temperature range indicator system Green Orange Red Low battery indicator OPERATION CHANGING F TO C ARC InstaTemp is set to Fahrenheit by default To change to Celsius follow these simple steps Press and release the activation button to get a reading Once the reading appears on screen in Fahrenheit press and release the activation button again the reading will automatically change to Celsius Repeat to change back OPERATION TAKING A TEMPERATURE Before attempting to take a temperature reading Remove protective label prior to operation Move hair away from the path of the sensor Wipe perspiration from the forehead if apparent Ensure that the person has been in the room for 20 minutes Do not measure the person s OOOO temperature immediately after he she has been exposed to really cold or hot climates or has drunk a hot or col
3. 561 288 6508 PT 100174 Revision 01
4. ARC Instalemp Non Touch Thermometer User Manual ARC Devices Ltd Copyright ARC Devices Ltd 2015 Welcome to your new state of the art ARC InstaTemp digital infrared non touch thermometer The ARC InstaTemp is a digital non touch thermometer that measures and displays human body temperature This device is intended for use by responsible adults at home To ensure the best results with your ARC InstaTemp thermometer please be sure to read the following operational and procedural manual carefully If you give this device to another adult it is vital that you also pass on this user manual The ARC InstaTemp is a sophisticated technologically advanced electronic medical device that has been carefully engineered to quickly and accurately measure human body temperature without requiring any contact with the human body Do not use this device for any other purpose Only use ARC InstaTemp in ambient temperatures ranging from 50 104 F 10 40 C The thermometer and person must remain in a place with no change in room temperature and away from ventilation sources and heat sources for at least 20 minutes before measuring temperature GETTING TO KNOW The ARC InstaTemp Manual NOTE PLEASE READ PRECAUTIONS BEFORE OPERATING ARC InstaTemp GETTING TO KNOW The ARC InstaTemp ARC InstaTemp Infrared Sensor Backlit LCD Display Screen Remove protective label prior to
5. ainst any defects that are due to faulty material or workmanship for a period of two years from the original date of consumer purchase This warranty applies when used for normal household use in accordance with the Use and Care Manual and excludes the battery and damage to the product resulting from accident or misuse This product is not warranted when used in a professional environment In no event shall ARC Devices be liable for any special incidental indirect or consequential damages in connection with the purchase or use of this product or costs over the original cost of the product If the product should become defective within the warranty period contact ARC Devices Customer Support Department at 561 288 6508 for repair or replacement at no charge ARC Devices reserves the right to replace a defective product with the most comparable product currently available While this warranty gives you specific legal rights you may also have other rights which vary from state to state or province to province ARC Devices ARC Devices Ltd 2 Deerpark Industrial Estate ARC o ranmore ad Co Galway Ireland Phone 353 91 398 191 info arcdevices com www arcdevices com In accordance with our policy of continual product improvements we reserve the right to make technical changes to the product without notice Distributed by ARC Devices USA Inc 1200 N Federal Hwy Ste 207 Boca Raton FL 33432 USA miam
6. blood vessels and cools the skin can occur in the early stages of a fever In this case the person s temperature may be unusually low e Only use the ARC InstaTemp in climate temperatures ranging from 50 104 F 10 40 C PRECAUTIONS Outside of this range a will be displayed when a measurement is taken repeat the measurement inside the 50 104 F 10 40 C range after waiting at least 20 minutes Do not subject the ARC InstaTemp to temperatures above 104 F 40 C or below 45 F 7 C e Do not use outside or close to a heat or cooling source Using the thermometer in these conditions may affect the accuracy of the temperature reading e Do not allow the ARC InstaTemp thermometer to become damp or immersed in water or other liquids e Do not touch the lens of the infrared sensor The sensor is the most important and sensitive part of the device e Do not attempt to measure body temperature with the thermometer if a The thermometer has been exposed to extreme conditions b It has been exposed to electric current or electromagnetic fields c It has been exposed to moisture d It has been dropped or shows any signs of damage or malfunction e If there is any visible dust or dirt on the device lens or in the device lens opening e Do not attempt to fix or repair the thermometer yourself PRECAUTIONS Do not attempt to replace the internal batteries The internal batteries are non removab
7. d liquid as it may temporarily change the surface temperature of the skin In these instances wait 20 minutes before taking a temperature reading Do not touch the lens of the sensor It is the most delicate part of the ARC InstaTemp D OPERATION TAKING A TEMPERATURE Point the thermometer at the person as shown below Ensure the device is 0 5 1 25 ins 1 3 cm from the forehead above the eyebrows and between the eyes ARC InstaTemp must be held steady perpendicular to and pointing directly at the center of the forehead at the area above the eyebrows and between the eyes when taking a temperature 0 5 1 25 1 3cm Q Point and Click Hold the ARC InstaTemp in position and press and release the activation button once simply point and click Hold the thermometer in position until the display is illuminated and a temperature reading is displayed on the screen OPERATION TAKING A TEMPERATURE The temperature reading will be displayed for 4 seconds Temperature Range Indicator System The temperature range indicator will be green orange or red depending on the temperature measurement detected Should you wish to take a second reading wait for 5 seconds and repeat Do not hold the activation button between measurements UNDERSTANDING THE TEMPERATURE RANGE INDICATOR SYSTEM The thermometer measured a temperature lt 89 5 F lt 32 C The temperature range indicator is r
8. ed and LO is displayed UNDERSTANDING THE TEMPERATURE RANGE INDICATOR SYSTEM The thermometer measured a temperature 289 5 F lt 94 9 F 232 0 C lt 34 9 C The temperature range indicator is red and a temperature reading is displayed UNDERSTANDING THE TEMPERATURE RANGE INDICATOR SYSTEM The thermometer measured a temperature 295 0 F lt 96 7 F 235 0 C lt 35 9 C The temperature range indicator is orange and a temperature reading is displayed UNDERSTANDING THE TEMPERATURE RANGE INDICATOR SYSTEM The thermometer measured a temperature 296 8 F lt 99 0 F 236 0 C lt 37 2 C The temperature range indicator is green and a temperature reading is displayed UNDERSTANDING THE TEMPERATURE RANGE INDICATOR SYSTEM CN 5 N The thermometer measured a temperature 299 1 F lt 100 5 F 237 3 C lt 38 0 C The temperature range indicator is orange and a temperature reading is displayed UNDERSTANDING THE TEMPERATURE RANGE INDICATOR SYSTEM The thermometer measured a temperature 2100 6 F lt 109 1 F 238 1 C lt 42 8 C The temperature range indicator is red and a temperature reading is displayed UNDERSTANDING THE TEMPERATURE RANGE INDICATOR SYSTEM The thermometer measured a temperature gt 109 1 F gt 42 8 C The temperature range indicator is red and HI is displayed UNDERSTANDING THE TEMPERATURE
9. from press of scan button TECHNICAL SPECIFICATION Measurement Display Time 4 sec 0 5 seconds before automatic shutdown Automatic Switch Off After the display period is complete the ARC InstaTemp will automatically shutdown to conserve measurement lifetime Power Supply Contains 2 AAAA Alkaline Batteries internal non replaceable Battery Life Approx 7 500 measurements Thermometer Size 1 37ins x 0 55ins x 5 08ins 34 8mm x 14 0mm x 129 0mm Weight 1 9402 55gm Electromagnetic Compatibility This device complies with the EN60601 1 2 standard for electromagnetic compatibility WARRANTY The ARC InstaTemp thermometer has a limited two year warranty Should service be required during or after the warranty period you must call ARC InstaTemp s Customer Service Department at 561 288 6508 to obtain a return authorization number and shipping address Repackage the thermometer carefully in its original packaging or securely packed to avoid damage during shipping Include the original sales slip indicating the date of purchase a note describing the problem your authorization number and your return address Send the ARC InstaTemp thermometer prepaid and insured Answers to any question regarding operation of the ARC InstaTemp thermometer may be obtained by calling us at 561 288 6508 Monday Friday 8 00 AM to 5 00 PM ET WARRANTY Limited two year warranty ARC Devices warrants this product ag
10. hat protects human health and the environment Consult your municipal authority or your dealer for information about disposal INFORMATION The ARC InstaTemp non touch Infrared Thermometer is a fast accurate and non intrusive device for measuring a persons temperature This device is intended for home use only Point the thermometer at the person Ensure the device is 0 5 1 25 ins 1 3cm from the forehead Press and release the activation button once and hold the thermometer in position until the backlight illuminates a temperature reading is displayed The ARC InstaTemp is fast accurate and designed to allow the person to rest undisturbed The ARC InstaTemp must not come into contact with a person when measuring temperature The ARC InstaTemp thermometer cannot take an accurate body temperature reading from anywhere other than the forehead and should not be used to do so This INFORMATION product is intended for household use only Use of this thermometer is not intended as a substitute for consultation with your physician ICON IDENTIFICATION This instruction manual belongs to this device It contains important information about starting up and operation of the thermometer Read the instruction manual carefully as non observance of these instructions can result in serious injury or damage to the device Manufacturer Caution consult section titled Understanding the Temperature Range Indicator Sy
11. le non replaceable and non serviceable e Do not open the thermometer casing elf the device touches or comes in contact with the person a Do not take a measurement for 5 minutes b Check the device lens and opening for contaminants c To clean the device please use a standard IPA wipe x 7 A A x CLEANING Do not touch the lens of the sensor It is the most delicate part of the ARC Insta Temp thermometer and must be protected from dirt and damage Do not immerse the ARC InstaTemp in water or other liquids It is not water resistant Take care not to scratch the lens of the sensor the display or the housing Never use aggressive cleaning agents CLEANING Zz Clean the thermometer using an IPA wipe DISPOSAL This symbol means that according to local laws and regulations your product should be disposed of separately from household waste Please note this product contains batteries and magnets and therefore must be disposed of according to local laws and regulations Do not dispose of this product in a fire as batteries may explode when exposed to excessive heat When this product reaches its end of life take it to acollection point designated by local authorities Some collection points accept products for free DISPOSAL The separate collection and recycling of your product at the time of disposal will help conserve natural resources and ensure that it is recycled in a manner t
12. ssage indicates an internal problem with the thermometer If an Er message appears contact your product supplier and or www arcdevices com TROUBLESHOOTING The thermometer battery capacity is too low to take a reading and your thermometer needs to be replaced TROUBLESHOOTING o a The battery has depleted and can no longer take a temperature reading Your thermometer needs to be replaced PRECAUTIONS Essential safety steps to be read and noted before use e Read this manual and always follow the instructions as specified when using the ARC InstaTemp e Using this thermometer is not a substitute for consulting your physician e The ARC InstaTemp and the person must remain in a stable climate for at least 20 minutes before a reading can be taken Do not measure the persons temperature immediately after he she has been exposed to really cold or hot climates or has drunk a hot or cold drink In these instances wait 20 minutes before taking a temperature reading Do not apply any hot or cold compress cloth or gel based on the person s forehead prior to the measurement for at least 20 minutes e Do not drop tap or shake the ARC InstaTemp thermometer It is a precision device and any damage may result in an inaccurate reading e The temperature in the forehead area differs from the internal temperature which is taken orally or rectally Vasoconstriction an effect which constricts the
13. stem and Taking a Temperature ICON IDENTIFICATION Degree of protection against electrical shock there is no conductive connection to the person Type BF Protection DIRECTIVE 2012 19 EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on waste electrical and electronic equipment WEEE TECHNICAL SPECIFICATION Name and Model ARC InstaTemp Display System Digital display LCD with backlight Temperature Range 89 5 109 1 F 32 0 42 8 C Lo and Hi are displayed outside this range displayed for an indeterminate reading or use of the device outside its ambient temperature range TECHNICAL SPECIFICATION Operating Temperature Operational in 50 104 F 10 40 C environment Allow 20 minutes for the device to settle for each 5 F change outside the operational environment Storage Transport Temperature Please store the device within the temperature range 45 to 90 F 7 32 C Measurement Accuracy Laboratory Error ASTM laboratory accuracy requirements in the display range 98 6 F to 102 2 F 37 0 C to 39 0 C for IR thermometers is 0 4 F 0 2 C within the operating temperature range of 59 F to 95 F 15 C to 35 C per ASTM standard 1965 98 Whereas for Mercury in glass and electronic thermometers the requirement per ASTM Standards E667 86 and E1112 86 is 0 2 F 0 1 C Temperature Display Units F or C user selectable Response Time lt 1 second
Download Pdf Manuals
Related Search
Related Contents
WALKER LDJ SCIENTIFIC INC. Rockdale street Worcester,MA MANUEL D`INSTRUCTIONS 86A127EV00-Power6 - Service processor cable DELL Force10 S4810P PicoScope serie 3000D Guía del usuario Installation instructions Istruzioni per l`uso KaltecSoft 0-Journal Grand Ales n°97.indd iiyama E481S-B 19 INCH MONITOR TFT VGA/DVI SPEAKERS 1280X1024 BLACK Fryware Pack-up Range DCサーボモータドライバ MS-100V取扱説明書 Copyright © All rights reserved.