Home

CR-SEBX Quick Start Guide

image

Contents

1. a provision for the filtering of multicast and broadcast packets In many networks there are sufficient multicast and or broadcast pack ets to slow the overall performance of the CR SEBX Based on the number of broadcast and multicast packets they can consume a substantial amount of the RF bandwidth By turning filtering on the CR SEBX will ignore these packets and limit transmission to packets with specific device addresses In some instances it is desirable to have the CR SEBX transmit the multicast and broad cast packets in such cases filtering should be disabled Note that filtering broadcast packets also filters multicast packets but filtering multicast packets does not filter broadcast packets If requiring a login is desired select Yes from the drop down menu and the Username Access code Password and Password Verify fields will become active If requiring a login is not desired selecting No grays out the fields and renders them inactive Click on Apply then click on Save Settings to store the system configuration changes in non volatile FLASH memory The user may either click on Reset to reboot the processor click on Logout to end the browser session or simply close the browser window 3 Run a communications test To run a communications test connect the Master CR SEBX to the central network The Slave CR SEBX can be connected to the remote device network segment or be left unconnected to any network Wit
2. CR SEBX is on This indicates that the Slave CR SEBX has linked to the Master CR SEBX through the wireless connection The RF Link LED is on for the Master CR SEBX when any one Slave CR SEBxX is linked If a DHCP or BOOTP server is being used the Slave CR SEBX will be assigned an IP address immediately after linking with the Master If a DHCP or BOOTP server is not available the IP address of the Slave CR SEBX must be set manually Refer to Step 1b Once the Slave CR SEBxX is linked with the Master CR SEBX from a PC on the network ping the Master CR SEBX Use the Ping program under Windows and the IP address assigned to the Master CR SEBX Note If a router is between the PC and the CR SEBxX check with your network administrator to make sure the router will pass the pings through Next from the same PC ping the Slave CR SEBX by using the Slave CR SEBX IP address instead of the Master IP address This ping operation will exercise the wireless link between the Master and Slave CR SEBXs If the Slave CR SEBX is connected to an Ethernet device that supports pings ping that device by using its IP address in place of the Slave CR SEBX s IP address These ping tests validate the entire link from the central wired network to the end Ethernet device Additional settings are available for issues such as e Avoiding interference with 802 11 Wireless Ethernet LANs e Co locating multiple radio networks e Conforming to European power requi
3. ct the CR SEBX to a hub or router Plug one end of the Ethernet Cable into the CR SEBX and the other end into the PC or network using the appropriate cable A pair of CR SEBXs is setup by performing the following steps 1a Assign IP addresses to the CR SEBXs using a DHCP server OR 1b Assign IP addresses to the CR SEBXs using the IP Hunter Utility which is included on the CR SEBX Install CD See Page 2 2 Set one CR SEBX to be the Master using the HTML Browser Session See Page 3 3 Run a communications test See Page 3 1a Assign IP addresses to the CR SEBXs using a DHCP or BOOTP server The CR SEBX is shipped from the factory set up to receive its IP address from a DHCP or BOOTP server If a server is not available please go to step 1b to manually assign the IP addresses Verify the Ethernet Link LED is green After a few seconds the DHCP or BOOTP server can be queried to determine the IP address assigned The MAC address of the CR SEBxX is on the side of the unit and the default host name is Cirronet_ SEM Note CR SEBXs are shipped from the factory with the IP address set to 0 0 0 0 1b Assign IP addresses to the CR SEBXs using IP Hunter When connecting the CR SEBX to a network without a DHCP or BOOTP server or in situations where they will not be used to set the IP addresses the CR SEBX CD has a device detection and IP setting utility named IP Hunter This utility will detect all Cirronet Ethernet devices on t
4. h power applied to both CR SEBXs and after the power on reset cycle has been completed verify that the Ethernet Link LED on the Master CR SEBxX is on This indicates a valid Ethernet connection to the network Also verify the RF Link LED on the Slave
5. he local network even those with no IP address For those units without an IP address IP Hunter can set the IP address and then open a browser session with that device to allow for further configuration The IP Hunter will display devices that already have IP addresses and will open browser sessions with those units but will not change the IP address already set If the PC is not connected to the CR SEBX or an active network the Ethernet adapter will not be active Depending on the PC it can take up to 30 seconds once the PC is connected to an active network or CR SEBX for the PCs net work card to become active After verifying that the computer s Ethernet Link LED is on open IP Hunter by double clicking on the file IPHunter exe on the CR SEBX CD Click on the Search button to begin the search for Cirronet devices only Cirronet Ethernet devices will be displayed Ethernet devices from other manufacturers will not be displayed even if they have no IP address Any Cirronet devices found will be displayed on the screen along with the IP address if any the netmask the MAC address and the DHCP host name Double clicking on a device with an IP address of 0 0 0 0 will bring up the IP change dialog box Enter the desired IP address and the default netmask will automatically be entered Anew Host Name may be entered if desired however the MAC Address cannot be changed Note PHunter will allow any IP address to be set If an IP adres
6. rements Please refer to the User s Manual on the CD to use the advanced configuration settings and RF tools for additional CR SEBX settings or if any problems are encountered Cf RECON EE 5375 Oakbrook Parkway Norcross Georgia 30093 Tel 1 678 684 2000 Fax 1 678 684 2001 www cirronet com Part M 2410 0025 Rev CR SEBX Quick Start Guide This guide is intended for users familiar with Ethernet networks Users unfamiliar with Ethernet networks should consult the Users Manual located on the CRSEH X Install CD The CR SEBX comes with the items shown below Identify the various components before beginning z E CR SEBX pE EEN Quick Start f c Guide wo N a _ lie P Remote Radi i Se Power _ Assembly lt D _ CRSEB X l ai UPP Install CD Crossover Ethernet Cable Ethernet Cable St wy Yellow Gray a oe ai i Console Cable Mount the Remote Radio Assembly RRA and pull the cable to the location of the CR SEBX Attach the 16 pin connector to the end of the CR CBLEx cable according to the pinout instructions included with the cable Plug the 16 pin connector into the CR SEBX Connect power by plugging one end of the wall mount power supply into the CR SEBX and the other end into a wall outlet A green LED on the unit will turn on indicating power is present The CR SEBX is set up to use the Ethernet Cable to connect to a PC A Crossover Ethernet Cable is provided to conne
7. s is set that is not on the same subnet as the PC running IP Hunter communications with that CR SEBxX will no longer be possible from that PC Click OK and the IP address will be entered in the CR SEBX and displayed in the IP Hunter window 2 Set one CR SEBX as the Master When using CR SEBXs one unit and only one must be set as the Master All other CR SEBXs must be set as Slaves When shipped from the factory all CR SEBXs are set as Slaves In typical installations the Master CR SEBX is the CR SEBX connected to the central Ethernet network HTML Setup Browser Session Double click on the IP number in IP Hunter or enter the IP Address in your browser to launch an HTML setup session A login screen will display Enter the default Username admin and default Password Cirronet case sensitive Click on OK and the main browser window will display The Confiuration Parameters will appear on the left browser pane with the change edit fields displaying in the main browser window right pane Click on the Bridge Settings link in the left browser pane Bridge Settings Mode Master gt Filtering disabled Require Login No UsernamelAccess code I Password 00 Verify Cancel Click on the drop down arrow to the right of the Mode field and select either Master or Slave Remember that one and only one CR SEBX may be set as the Master Filtering The CR SEBX includes

Download Pdf Manuals

image

Related Search

Related Contents

Guía docente 2006/2007  INSTALLATION INSTRUCTIONS    Samsung MG1480STD Manual de Usuario  Samsung 24" LED aukščiausios kokybės praktiškiausias liečiamasis monitorius Vartotojo vadovas  Logitech Joystick 3 User's Manual  GRAND`O evo (35316.A), page 6 @ Preflight  Nikon mec-2-fl-d60-n105 User's Manual  Here - PDAdb.net  Istruzioni per l`Uso  

Copyright © All rights reserved.
Failed to retrieve file