Home Security System User Manual
Contents
1. Command On 17 1 Off 17 0 System default Off 10 8 Turn on off the function of anti decode In order to prevent people from decoding the alarm system it is recommended to turn on this function Disarm only by the keypad Command On 18 1 Off 18 0 System default Off 9 Turn on off the reminder for phone line trouble It will warn you if the phone line is cut or short circuit It will sound three beep every 10 seconds Command On 22 1 Off 22 0 System default On 10 Set the ringing times Call the alarm host after the ringing circle it will get through automatically At this time you can remote control the alarm system For example set the circle times as 04 and then you dial the number of the alarm system it will get through after you hear 4 times of the ring Command 12 XX XX shows times of ring from 00 12 00 means the host will not get through and you can not remote control the system System default is 00 11 Set the alarming time of siren You can set alarming time of the siren according to the use s request from 0 to 30 minutes Command 29 XX XX is 00 30minutes System default 01 minute 11 12 Turn on off the warning tone of remote controller Turn on this function the siren will make a short beep each time you press the remote controller Command On 8 Off 8 System default On 13 Reset Reset means deleting all registered information including
2. e Fe Glass Sensor Panic Button Remote Controller j N e J nni y Wireless Smoke Gas Detector Wireless Pet Detector Immune PIR Detector Optional sensors detectors are packed separately You can choose according to your specific requirements 15 Typical house configuration Door window Garage smoke T PIR Movement Detector lt Detectors VI Technical Parameters Main Panel Power Supply AC 220V 10 DC 9V Inside Battery Ni MH rechargeable battery DC 7 2V Working Current lt 50mA Alarm Current s300mA Wireless Receiving Frequency 315 4833MHz 0 5MHz Wireless Receiving Sensitivity 5mV m Anti jamming Intensity 1V m frequency range 20 1000 MHz Outside Alarm Siren 110db Working Condition Temperature 10 C 40 C Relative Humiditys90 Detector Capability 99pcs 16 Wireless Door Window Detector Power Supply DC12V built in 12V battery Static Current lt 20uA Transmission Current lt 15mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m Alarm Distance 15mm Working Condition Temperature 10 C 40 C Humidity lt 90 rh Wireless PIR Detector Power Supply DC9V built in 9V battery Static Current lt 100uUA Transmission Current 20mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m Detective Speed 0 3 3m s Detective Distance 5 12m Detective Range Horizontal 110 Vertical 60 Working Con
3. passwords All the settings will return to the original status Command 0000 IV Operation Instructions pan 1 Out Arm Press the Out amO button on the remote controller or press Out button on the main panel for 2 seconds 30 seconds later there will be a beep and the OUT LED on the main panel will flash The system enters Out Arm mode and all the detectors will be in working status 12 2 Home Arm Press the Home am button on the remote controller or press Home button on the main panel for 2 seconds 30seconds later there will be a beep and the Home LED on the main panel will flash The system enters Home Arm mode Detectors inside the house in inner defense zone will not work only the detectors outside the house in outside defense zone will work so that people inside can move freely but others who break in from outside will trigger the alarm 3 Disarm Press Disarm O button on the remote controller or input password disarm by the main panel the system will enter into disarmed status 4 Emergency When there is an emergency press the Emergency D button on the remote controller or the main panel the system will alarm immediately no matter it is in arm or disarm status 5 Receive alarm call When there is an alarm the siren will start ringing the alarm indicator on the main panel will light up the defense zone indicator
4. send SMS to the numbers Command 31 the 1st User phone number 32 the 2nd User phone number 33 the 3rd User phone number 34 the 4th User phone number 35 the 5th User phone number 36 the 6th User phone number 38 the 1st phone number of monitoring center 39 the 2nd phone number of monitoring center Note Do not setup the monitoring center number if you do not have monitoring center You can enter a blank order if you want to delete one Alarm Phone Number Fox example To delete the 4th Alarm Phone Number input 34 Operation sketch Input password default 1234 Alarm Phone No Settings 31 the lst User phone mmber 32 the 2nd Usty phone mmber 33 the 3rd User phone number 34 the 4th User phone mmber 35 the Sth User phone mmber 36 the 6th User phone mmber 38 the lst phone mumber of monitoring center 39 the 2nd phone mumber of monitoring center Record Voice Message 4 Change password Command 10 password password must be 4 digits This password is used for remote control The following are special settings 5 Defense zone setting You can set the type of defense zone according to your needs The system default is Instant Zone for all zones Only wireless zone 01 08 and wired zone 91 97 can be set Command Zone No 2 X X is zone type 0 Closes Zone do not send detecting information 1 Instant Z
5. Home Security System User Manual Profile For a better understanding of this product please read this user manual thoroughly before using it Warning Do not remove the front or back cover of the unit and keep it intact There is no part that can be repaired by user If repair is needed please send it to seller or authorized service point The information contained in this manual is prepared for the alarm system only It adopts a sustainable development strategy Therefore the company retains the right to modify or make improvement to any product described herein without giving prior notice All rights reserved The name of other companies or products referred to herein may be the brand or product name of their respective owners Thank you for purchasing this alarm system For proper use and your safety please read these instructions thoroughly and carefully before you put the system in use Keep this manual carefully for your reference in the future Precautions Please read and follow the brief instructions below otherwise physical danger or system damage may be incurred This manual contains more detailed information about safety issues concerning the system in other parts hereof Proper use Waterproofness Q Qualified maintenance service Read this manual The alarm system is Only those qualified carefully before you put not waterproof maintenance professionals the system in use Please keep it dry may repair the ala
6. M and the other to 1 or 2 or 3 or 7 lt gt 1 e ye oom tm Nw e U eeeeleelsleis e zone 91 the 1st wired detector GND 12V zone 92 the 2nd wired detector Function settings Before any operation please enter passwords Default is 1234 and press button PROGRAMME You will hear two beeps and the OUT ARM HOME ARM LED light up indicating the system enters set up status Each time you input an instruction hearing two beeps means successful If you hear four short beeps it means false operation You have to try again Please press EXIT to end the set up status System will exit automatically if there is no operation for 30 seconds Record alarm message Input 6 to start record message after hearing a beep After 10 seconds the system exits recording with two beeps automatically Each new recorded message will replace the last message The message should be short and clear For example This is room xxx building xxx intruder please come to offer help Press 6 on the main panel it will play the recorded message through the telephone 2 Add or delete wireless detectors Each detector has its unique ID It must be coded with the main panel for normal working If it is not coded with main panel the main panel would not identify it and could not receive the signal so the alarm will fail The door sensor and the remote controller in the standard kit have bee
7. dition Temperature 10 C 40 C Humidity lt 90 rh Remote Controller Power Supply DC 12V built in 12V battery Static Current 0 Transmission Current 15mA Transmission Frequency 315 433 0 5 MHz 17 Transmission Distance No obstacle 80m Working Condition Temperature 10 C 40 C Relative Humiditys90 VII Care and Maintenance The alarm system has excellent design and used advanced technologies It shall be used with care The following suggestions are required to maintain your obligations under the warranty terms and for prolonging the service life of the system gt gt Place the control panel and all parts and accessories out of children s reach Keep the alarm system dry Rain humidity and various fluids or moisture all will corrupt the electronic circuit Do not use or place the alarm system in dirty locations otherwise the electronic elements will be damaged Do no place the system in excessively hot locations High temperature will shorten the service life of electronic equipment damage batteries deform or even melt some plastic parts Do not place the system in excessively cold locations Otherwise condensation many occur and damage the circuit board of the alarm system It is recommended that you check and test the alarm system periodically Check the main unit every three months 1 Whether it can arm disarm normally 2 Whether it can dial the number for alarm normally 3 Whe
8. itter Then adhere them to the appropriate position Magnet should be near to the side of transmitter with indicator The two should align with each other and the distance should not exceed 10mm Please plug out the antenna for better signal If the low power indicator is on please change the battery 3 Wireless PIR PIR detectors are used to detect the detector window movement within a a certain range door lt Fix the adjustment bracket on the wall with the provided screws s and attach the detector to the bracket It is recommended to mount it at a height of 2 2 2m above the floor Effect of the PIR detection is best when the detection direction is in 90 angle with the walking direction of the intruder Choose the most suitable installation place and angle according to actual situation and taking the following installation diagram as reference to ensure the detection effect is best Please do not fix it under direct sunlight or other strong lights and also keep it away from places with frequent strong air stream If the low power indicator is on please change the battery 4 Wired detectors At the back side of the host there is a wired connector which can link with 7 wired detectors The 12v and GND are to connect with the power supply the COM is the public port When using the wired detectors connect the 12v and GND to the power supply connect one line of the wired detector to the CO
9. lem for you as soon as possible 19 Brief list of setting command Description Command Remarks Record alarm message 6 Replay the message 6 Code wireless detectors 7 Delete wireless detectors 7 Set Alarm Phone Numbers 31 35 phone number Set monitoring center 38 39 number Do not set it if do not have number a monitor center User password 10 new password new password should be 4 digits default 1234 Zone No 01 08 91 97 X indicates zone type Defense zone type zone No 2 X 1 instant 2 delay 3 urgent 5 inner 0 close Defense zone warning zone No 71 ON tone zone No 70 OFF System Default Remote controller warning 8 ON System Default tone 8 OFF Anti interference 17 1 ON 17 0 OFF System Default Anti decode 18 1 ON 18 0 OFF System Default Telephone line trouble alert 22 1 ON System Default 22 0 OFF Ringing times 12 XX XX 00 12 default 00 Siren alarming time 29 XX XX 00 30 minutes default 01 Reset 0000 20 FAQ Problems Causes Solutions i _ Arm the unit 1 Hasn t armed 2 Operate after 30 2 Less than 30 seconds seconds Cannot alarm by phone after arming 3 Set wrong phone number 4 The two parts of door window sensor is installed too far from each other 5 Haven t activated PIR 6 Hasn t checked code 3 Set the number again according to the manual 4 Adju
10. lephone line with the port of out line and telephone with the telephone set That is to say the telephone must be connected with main panel The telephone can still work normally b Power the system on and switch it to ON the power status LED will blink and the system sounds beep showing the main panel works normally It will sound three beep every 30 seconds which reminds user of setting alarm phone numbers The sound beep will stop after finishing the alarm phone number setting Please press on the remote controller to make the system disarmed to avoid activating the siren to alarm when registering sensors defense zone indicator power switch 1 siren H telephone out line Attention gt gt gt 2 Door sensors are used for detecting the status of open and close of windows and doors lt will detect it and send the signal to main panel gt Try to install the main panel in the center of defense zone and pull out the antenna to get longer wireless receiving distance Installation position should be far away from huge metal objects and wireless interference Connect the trunk line with main panel in order that it can dial out immediately when there is an alarm Install the main panel in a hidden place Door sensor less than hmm Tear apart the double side adhesive tape on the magnet and the transm
11. n coded to the main unit If you want to add more wireless sensors please refer to the instructions as follows a Input 7 there will be a beep and the ARM status LED starts flashing The unit enters coding status Now you can start to register sensors by triggering the new sensors or detectors It means successful operation if you hear two beeps The unit will exit automatically if there is no operation for 3 minutes b How to trigger the detectors Door sensor separate the two parts PIR detector move across the detector remote controller press any key on it gas and smoke detectors there is a black switch on the left side you can press it to code it with main panel After finishing coding please press to exit two beeps c Delete sensors In coding status input 7 you will hear beep beep At this time all coded information has been deleted There are 32 defense zones so you can install sensors in any of defense zone You will know what sensors are triggered from the screen of main panel You can input XX and then trigger sensors and then enter into this defense zone For example if you want to code the detectors and sensors into the 2nd or 4th defense zone do as follows Enter 7 and trigger sensors zone 2 Enter 02 and trigger sensors SS gt Zone 4 Enter 04 and trigger sensors Dawa 3 Set alarm phone numbers when the system alarms it will call or
12. one default alarm immediately if triggered 2 Delay Zone alarm 30 seconds after being triggered 3 Urgent Zone It will alarm if triggered no matter it is in arm or disarm status 5 Inner Zone In home arm situation it won t alarm if detectors are triggered E g If you want to set the second defense zone to be inner zone You can input 0225 Suggestions Usually we set the door window sensors installed around windows balcony and doors as Immediate Zone The detectors in this area will activate alarm in any mode of arming Set wireless PIR detectors as Inner Zone they will work in the mode of Out Arm but do not work in the mode of Home Arm You can set the door sensors at the main gates as Delay Zone if you do not want to take remote controller when going out In this case you can disarm the system within 30 seconds after opening the door but the alarm system will not activate during this period 6 Turn on off warning tone for defense zone If you turn on the warning for defense zone it will beep for three times to remind users of arming the system before going out Command On Zone No 71 Off Zone No 70 System default Off 7 Turn on off the function of anti interference When turning on the function of anti interference in arming status it will activate siren to alarm not calling users if someone interferes the alarm system with the same frequency
13. rameters Care and Maintenance 11 11 11 12 12 12 12 13 13 13 14 14 16 18 10 11 12 13 14 Features Anti interfere function when someone interferes it with the same freguency the main panel will activate siren to alarm Support anti decode with remote control Digital LED defense zone display users can know which defense zone is triggered 32 wireless defense zone display 1 to 32 and 7 wired defense zone display 91 97 Every defense zone can set independently arm disarm delay alarm and so on Have the function of one button arm Home arm or Out arm by pressing one button on remote controller Can set the reminder sound of defense zones warn users to arm the alarm system when going out Can work with other products of our company such as wireless big outdoor siren and mini siren It stores 2 monitoring center and 6 user phone numbers to dial out and play the recorded message when alarming Can arm disarm with remote controller or keypad on the main panel Can arm disarm listen in by calling the main panel number Telephone line failure alert if telephone line is cut or short circuit the siren will alarm Have the superior of alarm call even when the alarm phone number is busy Built in backup battery can continue to work when electricity is cut off or in failure l Installation 1 Main panel a Insert the siren to the port of main panel and connect te
14. rm system Operate in accordance with the instructions herein Backup Original parts and Addition of batteries other equipment Be sure to back up all Only original parts and Before adding other important information batteries approved by equipment please read the stored in the system manufacturer may be used user manual for detailed otherwise the warranty term safety instructions Be sure may be breached and danger not to connect incompatible may occur products to the system AAN Switch on safety Interference Switch off in restricted areas Do not switch the Device All wireless devices may be Follow any restrictions on when wireless phone susceptible to interference Switch the device off in use is prohibited or when which could affect aircraft near medical it may cause interference performance equipment fuel chemicals or danger or blasting areas Catalogue Features Installation Main panel Door Sensor Wireless PIR Detector Wired Detector Function Settings Record alarm message Add or Delete Wireless Detectors Set Alarm Numbers Change password Defense Zone Setting 9 9 Warning Tone for Defense Zone 10 Anti interference Anti decode 10 11 Phone Line Trouble Reminder Ringing Times Setting Siren Alarming Time Remote Controller Warning Tone Reset Operation Instructions Out Arm Home Arm Disarm Emergency Receive Alarm Call Remote Control by Phone Components List Technical Pa
15. st the installation place of the door sensor 5 Activate the PIR 6 Check code again Remote controlling distance is too short and the light indicator is not on bright enough 1 The battery of remote controller is rusty 2 Low battery 1 Clean the rust Change battery N Light indicator of door sensor and PIR is always on Low power battery Change battery Dial alarm number slowly The main panel has stored other numbers Set it again according to the operation manual The main panel cannot receive signals from the accessory 1 Low power battery in the accessory 2 There is block between the control panel and the wireless accessory or the distance between them is too far 3 The accessory has not been coded to the panel 1 2 Replace the battery Pull out the antenna of the accessory and the main panel and adjust the position 3 Code it to the main panel 21
16. ther it can receive wireless detectors signal normally 18 4 Whether the back up battery can work normally Check the wireless detectors once a month Trigger wireless detectors to see if system can alarm normally Check all detectors batteries to see if it s in low voltage Check whether wireless detectors can send signal to the main unit normally Since the alarm system is continuously in operation or standby mode the supply adaptor of the control panel shall be connected to a safe and reliable socket lt Do not place the system near your bedroom or office table because the siren will make high loudness sound in the case of alarm which may adversely affect your rest or work lt If the alarm system will not be used for a long time please disconnect the system from the power supply lt Please do not disassemble repair and alter the products without permission or it may cause accidents and faults lt Do not drop this product on the ground or on hard objects as it may lead to massive impact to cause faults and damages lt Without approval and consent of relevant authorities please do not set 110 119 or the alarm phone number of police station for this main unit Please read the suggestions above carefully and follow the instructions herein If any of the equipment does not work properly please send it to the dealer or authorized service point for repair We will try our best to solve the prob
17. will display the number and the system will make alarm call After answering the call user will hear the recorded message and then can do the following 13 operations Press listen in for 30 seconds You will hear what is happening at the alarm spot Press confirm that you have received the alarm and the system will stop alarm If you do not input the alarm system will continue to dial out all alarm phone numbers circularly 6 Remote control by phone You can call the host phone number to remote control the system After getting through input passwords If the password is correct the system will sound beep twice If wrong it sounds beep four times And then you can control the system with following commands Press 1 to arm make sensors working Press 2 to disarm make sensors stop working Press to listen in for 30 seconds for continued listen in press again to listen in for another 30 seconds Press to exit Note The system will hang off automatically if passwords are wrong for 3 times or not any operation for 20 seconds V Components list Main panel 1 pc Remote controller 2 pcs PIR sensor 1 pc 14 Door sensor 1 pc Siren 1 pe Power adapter 1 pc Phone cable 1 pc User manual 1 pc The following sensors are optional Ba oo amp e Wireless Outdoor Signal Repeater Wireless keypad Siren with flash v fa ce ws i
Download Pdf Manuals
Related Search
Related Contents
Sterile Oil for Tissue Culture Sterile Oil for Tissue Culture Tecumseh AE2410A-AA1ASC Drawing Data C - Site de la ville de Valenton リンク構成 DDL、S-設計 FLIR K40/K50のマニュアルはこちら SH PMG-W SH PRC-W PanaMag AF-92 HEATER MODULE AF-93 CHEMICAL 02_P.C. Analizador Espectros (ABR0022 P iastra ro tan te Copyright © All rights reserved.